• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 11
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 78
  • 37
  • 35
  • 20
  • 16
  • 15
  • 14
  • 12
  • 12
  • 12
  • 11
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Longevidade e fatores associados à falha de restaurações adesivas de dentes decíduos / Longevity and factors associated with failure of adhesive restorations in primary teeth

Dalpian, Débora Martini January 2016 (has links)
O objetivo desta tese foi avaliar a longevidade e os fatores associados à falha de restaurações adesivas em dentes decíduos. Para isto, foram desenvolvidos dois estudos retrospectivos. No primeiro, foi feita a análise da longevidade de restaurações realizadas após a remoção seletiva de tecido cariado em dentes decíduos. Foram avaliados os prontuários de pacientes atendidos durante os anos de 2007 a 2012 no ambulatório de Odontopediatria da Universidade Federal do Rio Grande do Sul. Os critérios de inclusão previram a realização de pelo menos um procedimento de restauração com remoção seletiva de tecido cariado, em dente decíduo, e o acompanhamento clínico e/ou radiográfico. A amostra foi composta por 254 dentes de 118 pacientes, com período de acompanhamento de 1 a 50 meses. A sobrevida das restaurações, após 24 meses, foi de 51%, sendo constatada uma associação positiva entre a falha do procedimento e maiores valores do índice de placa visível (p=0.01). No segundo estudo, foi realizada uma avaliação da longevidade e dos fatores associados à falha de restaurações em dentes decíduos, após a remoção total e seletiva de tecido cariado. Para isso, foi desenvolvido um estudo retrospectivo, no curso de Odontologia do Centro Universitário Franciscano, com base nos prontuários de pacientes infantis, atendidos durante os anos de 2010 a 2016, que receberam pelo menos uma restauração em dente decíduo e tiveram um acompanhamento mínimo de seis meses. Foram incluídos 123 pacientes e 316 restaurações de resina composta ou cimento de ionômero de vidro. Após 3 anos, as restaurações apresentaram sobrevida de 54,4% e taxa de falha anual de 18,3%. A análise de Log-rank mostrou que a remoção seletiva de tecido cariado (p=0,03), o uso de base forradora de hidróxido de cálcio (p<0,01) e o cimento de ionômero de vidro (p=0,04) como material restaurador, resultaram numa menor sobrevida da restauração. A regressão de Cox ajustada demonstrou que restaurações realizadas com remoção seletiva de tecido cariado apresentam 3,41 (IC 95% 1,37;8,46) vezes maior risco de falha, quando comparadas à remoção total de tecido cariado. Conclui-se, então, que as restaurações em dentes decíduos, realizadas por alunos de graduação, possuem limitadas taxas de sobrevida e que fatores relacionados ao paciente e ao procedimento influenciam no desempenho da restauração. / The aim of this thesis was to evaluate the longevity and factors associated with failure of adhesive restorations in deciduous teeth. For this, two retrospective studies were carried out. In the first, the longevity of restorations performed after the partial removal of carious tissue in deciduous teeth was analyzed. The records of patients treated during the period from 2007 to 2012 were evaluated at the School of Dentistry, Federal University of Rio Grande do Sul. The inclusion criteria predicted the accomplishment of at least one restoration procedure with partial removal of carious tissue in deciduous tooth and clinical and / or radiographic follow-up. The sample consisted of 254 teeth from 118 patients with follow-up period from 1 to 50 months. The survival rate of restorations after 24 months was 51%, with positive association between procedure failure and higher visible plaque index values (p=0.01). In the second study, longevity and factors associated with failure of restorations in deciduous teeth after total and partial removal of carious tissue were evaluated. For that, a retrospective study was developed in the Dentistry course of the Franciscan University Center, based on the records of pediatric patients treated during the period from 2010 to 2016, who received at least one restoration in a deciduous tooth and had minimum follow-up of six months. The study included 123 patients and 316 composite resin or glass ionomer cement restorations. After 3 years, restorations presented survival rate of 54.4% and annual failure rate of 18.3%. The log-rank analysis showed that the partial removal of carious tissue (p= 0.03), the use of calcium hydroxide liner (p<0.01) and glass ionomer cement (p=0.04) as restorative material, resulted in shorter survival rate of restorations. Adjusted Cox regression showed that restorations performed with partial removal of carious tissue were 3.41 (95% CI 1.37-8.46) more likely of presenting greater risk of failure when compared to total removal of carious tissue. It could be concluded that restorations in deciduous teeth performed by undergraduate students have restricted survival rate and that factors related to patient and procedure influenced the performance of restorations.
52

Avaliação ex vivo da resistência à tração, de pinos metálicos em raízes fragilizadas tratadas com laser Er:YAG e reforçadas com resina composta / Tensile bond strength of metal posts after the application of Er:YAG laser treatment to the weakened root canal reinforced with composite resin

Luciana Cavali Santello 07 February 2012 (has links)
O objetivo do estudo foi avaliar ex vivo a influência da aplicação do laser de Er:YAG na parede dentinária de raízes fragilizadas, reforçadas com resina composta. Cinquenta caninos superiores tiveram suas coroas removidas próximo da junção amelo-cementária e incluídas em bloco de resina acrílica. Após tratamento endodôntico foi realizada a fragilização das raízes. Os espécimes foram distribuídos aleatoriamente em 5 grupos (n=10),: Grupo I - não irradiado, tratado com ácido fosfórico 37%; Grupo II - irradiado com laser Er:YAG, 300mJ - 10 Hz; Grupo III - irradiado com laser Er:YAG, 300mJ - 10 Hz e tratado com ácido fosfórico 37% ;Grupo IV - irradiado com laser Er:YAG, 500mJ - 10 Hz; Grupo V - irradiado com laser Er:YAG, 500mJ - 10 Hz e tratado com ácido fosfórico 37%. Todos os espécimes receberem reforço intra-radicular com resina composta, foto-polimerizada por meio de pino foto-transmissor. No espaço promovido por este pino foi cimentado o pino metálico pré-fabricado, com cimento resinoso auto-adesivo de dupla polimerização. Os espécimes foram submetidos ao teste de Tração na Máquina Universal de Ensaios - INSTRON 4444. Os maiores valores para o deslocamento foram atribuídos ao Grupo I, estatisticamente semelhante ao Grupo III. Entretanto o Grupo III ocupa uma posição intermediária, podendo pertencer também aos GruposIV e V que foram estatisticamente semelhantes entre si e ao grupo II. / The aim of this study was to assess ex vivo the effects of Er:YAG laser as dentin treatment of weakened root canal reinforced with composite resin. Fifty upper canines were decoronated at cementoenamel junction and the roots were embedded in acrylic resin. After the endodontic treatment the roots were weakened and the specimens were randomly assigned to five groups (n=10): Group I - unirradiated, treated with phosphoric acid 37%; Group II - Er:YAG laser 300mJ - 10Hz; Group III - Er:YAG laser 300mJ - 10 Hz, treated with phosphoric acid 37%; Group IV - Er:YAG laser 500mJ - 10 Hz; Group V - Er:YAG laser 500mJ - 10 Hz, treated with phosphoric acid 37%. The intraradicular reinforcement was made in all specimens with composite resin using photo-transmitter post, which creates a space for the insertion of prefabricated metal post. The metal posts were inserted using a resin cement self-adhesive dual-cured. The tensile bond strength of specimens was tested in a universal testing machine - INSTRON 4444. The results showed that Group I was statistically similar to the Group III and presented the highest bond strength values. Group III also showed statistical similarity with Group IV and V, which were similar among them and the Group II.
53

Longevidade e fatores associados à falha de restaurações adesivas de dentes decíduos / Longevity and factors associated with failure of adhesive restorations in primary teeth

Dalpian, Débora Martini January 2016 (has links)
O objetivo desta tese foi avaliar a longevidade e os fatores associados à falha de restaurações adesivas em dentes decíduos. Para isto, foram desenvolvidos dois estudos retrospectivos. No primeiro, foi feita a análise da longevidade de restaurações realizadas após a remoção seletiva de tecido cariado em dentes decíduos. Foram avaliados os prontuários de pacientes atendidos durante os anos de 2007 a 2012 no ambulatório de Odontopediatria da Universidade Federal do Rio Grande do Sul. Os critérios de inclusão previram a realização de pelo menos um procedimento de restauração com remoção seletiva de tecido cariado, em dente decíduo, e o acompanhamento clínico e/ou radiográfico. A amostra foi composta por 254 dentes de 118 pacientes, com período de acompanhamento de 1 a 50 meses. A sobrevida das restaurações, após 24 meses, foi de 51%, sendo constatada uma associação positiva entre a falha do procedimento e maiores valores do índice de placa visível (p=0.01). No segundo estudo, foi realizada uma avaliação da longevidade e dos fatores associados à falha de restaurações em dentes decíduos, após a remoção total e seletiva de tecido cariado. Para isso, foi desenvolvido um estudo retrospectivo, no curso de Odontologia do Centro Universitário Franciscano, com base nos prontuários de pacientes infantis, atendidos durante os anos de 2010 a 2016, que receberam pelo menos uma restauração em dente decíduo e tiveram um acompanhamento mínimo de seis meses. Foram incluídos 123 pacientes e 316 restaurações de resina composta ou cimento de ionômero de vidro. Após 3 anos, as restaurações apresentaram sobrevida de 54,4% e taxa de falha anual de 18,3%. A análise de Log-rank mostrou que a remoção seletiva de tecido cariado (p=0,03), o uso de base forradora de hidróxido de cálcio (p<0,01) e o cimento de ionômero de vidro (p=0,04) como material restaurador, resultaram numa menor sobrevida da restauração. A regressão de Cox ajustada demonstrou que restaurações realizadas com remoção seletiva de tecido cariado apresentam 3,41 (IC 95% 1,37;8,46) vezes maior risco de falha, quando comparadas à remoção total de tecido cariado. Conclui-se, então, que as restaurações em dentes decíduos, realizadas por alunos de graduação, possuem limitadas taxas de sobrevida e que fatores relacionados ao paciente e ao procedimento influenciam no desempenho da restauração. / The aim of this thesis was to evaluate the longevity and factors associated with failure of adhesive restorations in deciduous teeth. For this, two retrospective studies were carried out. In the first, the longevity of restorations performed after the partial removal of carious tissue in deciduous teeth was analyzed. The records of patients treated during the period from 2007 to 2012 were evaluated at the School of Dentistry, Federal University of Rio Grande do Sul. The inclusion criteria predicted the accomplishment of at least one restoration procedure with partial removal of carious tissue in deciduous tooth and clinical and / or radiographic follow-up. The sample consisted of 254 teeth from 118 patients with follow-up period from 1 to 50 months. The survival rate of restorations after 24 months was 51%, with positive association between procedure failure and higher visible plaque index values (p=0.01). In the second study, longevity and factors associated with failure of restorations in deciduous teeth after total and partial removal of carious tissue were evaluated. For that, a retrospective study was developed in the Dentistry course of the Franciscan University Center, based on the records of pediatric patients treated during the period from 2010 to 2016, who received at least one restoration in a deciduous tooth and had minimum follow-up of six months. The study included 123 patients and 316 composite resin or glass ionomer cement restorations. After 3 years, restorations presented survival rate of 54.4% and annual failure rate of 18.3%. The log-rank analysis showed that the partial removal of carious tissue (p= 0.03), the use of calcium hydroxide liner (p<0.01) and glass ionomer cement (p=0.04) as restorative material, resulted in shorter survival rate of restorations. Adjusted Cox regression showed that restorations performed with partial removal of carious tissue were 3.41 (95% CI 1.37-8.46) more likely of presenting greater risk of failure when compared to total removal of carious tissue. It could be concluded that restorations in deciduous teeth performed by undergraduate students have restricted survival rate and that factors related to patient and procedure influenced the performance of restorations.
54

Avaliação da microdureza de resina composta polimerizada com fontes de luz halógena e LED, em função da densidade de energia luminosa irradiada / Knoop hardness analisys of a resin composite activated by halogen lamp and LED, varying the luminous density

Rosana Aparecida Pereira 08 July 2009 (has links)
No presente estudo, avaliou-se a microdureza da resina composta Z250 (3M ESPE), quando ativada em diferentes tempos (s), diferentes densidades de potência (mW/cm²), em relação à quantidade de energia irradiada (8, 12 e 16 J/cm²), com a finalidade de estabelecer uma densidade de energia luminosa mínima capaz de polimerizar adequadamente os compósitos. Foi utilizado um aparelho com fonte de luz halógena Degulux-Degussa, com 600 mW/cm² e dois aparelhos de fonte de luz LED, Ultraled XP (Dabi-Atlante) com 150 mW/cm² e LED Ultrablue-IS (DMC) com 300 mW/cm² e 600 mW/cm². Duas matrizes bipartidas de PTFE, de 1 e de 2 mm de espessura e um orifício central de 5 mm de diâmetro, foram usadas para confeccionar 60 corpos-de-prova, 5 em cada grupo. As duas partes da matriz foram contidas em um anel metálico com as mesmas espessuras. O material foi inserido na matriz e fotoativado de acordo com os diferentes tempos e a quantidade de densidade de energia luminosa para cada fonte de luz. Para obter os valores de microdureza Knoop, os espécimes foram levados ao microdurômetro Shimadzu HMV-2, com carga estática de 300 g por 5 segundos, para aferir as superfícies exposta (topo) e oposta (base) à fonte de luz, totalizando 120 medições. Os resultados foram submetidos aos testes ANOVA e Tukey, com nível de significância de 5%. Com os dados obtidos foi possível concluir que, com valores a partir de 16 J/cm² e 12 J/cm² de densidade de energia luminosa, espessuras de 2 mm de resina composta podem ser adequadamente polimerizadas utilizando-se fonte de luz halógena (600 mW/cm²) e LED (a partir de 300 mW/cm²) respectivamente. Contudo, estudos clínicos adicionais ainda são necessários para complementar este estudo / At this study it was evaluated the microhardness of the Z250 (3M ESPE) resin composite, when light cured for different periods of time (s), with different power densities (mW/cm²), related to the irradiated luminous energy density (8 J/cm², 12 J/cm² and 16 J/cm²), in order to establish a minimal energy density capable of adequately polymerize the composites. One halogen light curing unit Degulux- Degussa, with 600 mW/cm² of power density and two light-emitting diodes curing units Ultraled XP (Dabi-Atlante) with 150 mW/cm² and LED Ultrablue-IS (DMC) with 300 mW/cm² and 600 mW/cm² were used. Two bipartite PTFE matrices, with 1 and 2 mm of depth and a central orifice of 5 mm diameter, were used to make 60 specimens, 5 per group. The halves of the matrix were positioned inside a brass ring with both depths to prepare the specimens. The resin composite was inserted and light-activated according to the different periods and energy densities of each lightcuring unit. To evaluate Knoop microhardness, specimens were taken to a microdurometer Shimadzu HMV-2 with a static load of 300 g for 5 seconds, evaluating both exposed to light (surface) and opposite to light (base) exposition surfaces, totalizing 120 measurements. Results were submitted to ANOVA and Tukeys test with 5% significance level. Based on the obtained results, it was concluded that, starting from 16 J/cm² and 12 J/cm² of energy luminous density, 2 mm depth resin composite can be adequately polymerized utilizing halogen (600 mW/cm²) and LED ( starting from 300 mW/cm²) curing-units respectively. However, additional clinical studies are necessary to complement this investigation.
55

Beam profile characterization of light-emitting-diode curing units and its effect on polymerization of a resin-matrix composite

AlZain, Afnan Omar January 2017 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The general aim of this study was to investigate the influence of the localized irradiance beam profiles from multiple light-emitting-diode (LED) light-curing units (LCUs) on the polymerization pattern within a resin-matrix composite (RMC). Irradiance beam profiles were generated from one quartz-tungsten-halogen and various single and multiple emission peak LED LCUs using a camera-based beam profiler system combined with LCU power measurements obtained using an integrating sphere/spectrometer assembly. The influence of distance on irradiance, radiant exposure (RE) and degree of conversion (DC) on the top and bottom surfaces of a RMC increment, using various LCUs, at two clinically relevant distances was investigated. Molar absorptivity of the photoinitiators present in the nano-hybrid RMC (Tetric EvoCeram bleaching shade-XL) assessed was using UV-spectrophotometry. The correlation among irradiance, RE and DC was explored. A mapping approach was used to investigate DC, microhardness and cross-link density (CLD) within 5×5×2 mm specimens at various depths; top, 0.5, 0.7, 0.9, 1.1, 1.3,1.5 mm and bottom. The localized irradiance correlation with its corresponding DC, microhardness and CLD was explored, and localized DC correlation with microhardness was assessed. The DC was measured using micro-Raman spectroscopy, and CLD was assessed by an ethanol-softening method (%KHN reduction) using an automated microhardness tester. Molar absorptivity of diphenyl (2,4,6-trimethylbenzoyl) phosphine oxide was 20-fold higher than camphorquinone. Non-uniform LCU beam profiles caused localized polymerization discrepancies that were significant at specific depths and points within the specimens with respect to DC, microhardness and CLD, which did not follow a specific pattern regardless of the LCU or curing distance assessed. A moderate correlation was displayed among irradiance, RE and DC. The localized irradiance from the LCUs was weakly correlated with the corresponding DC, microhardness and CLD on the top surface of a RMC at both curing distances. The localized microhardness was moderately correlated with DC. In conclusion, polymerization within the RMC investigated was non-uniform and did not reflect the LCU irradiance pattern at the area assessed. Also, a mapping approach within the specimens provided a detailed polymerization pattern assessment occurring within a RMC increment. Therefore, the LCUs explored may potentially increase the risk of RMC fracture.
56

"Avaliação in vitro e in vivo da resina composta pré-aquecida em relação à cinética de polimerização / In vitro and in vivo appraisal of pre-heated resin composite with relation to polymerization kinetics

Daronch, Márcia 04 July 2005 (has links)
O objetivo do trabalho foi investigar múltiplos aspectos relacionados ao pré-aquecimento da resina composta anterior à fotoativação: o grau de conversão e a cinética da polimerização em função da temperatura de polimerização, tempo de fotoativação e profundidade; o desempenho da fonte aquecedora (temperatura máxima, estabilidade térmica do aparelho e variações de temperatura ao pré-aquecer compules) e aspectos clínicos (o efeito de ciclos de pré-aquecimento repetidos e prolongados sobre o grau de conversão, a variação da temperatura intrapulpar in vitro e a variação da temperatura in vivo ao usar resina composta pré-aquecida ou a temperatura ambiente. A conversão de monômeros e os parâmetros de cinética foram determinados através de FTIR-ATR. Os espécimes foram fotoativados por 5, 10, 20 ou 40s entre 3 o e 60 o C. Foram calculados o grau de conversão em tempo real, a taxa máxima de conversão, o tempo em que ocorreu a taxa máxima, e a conversão na taxa máxima. Os dados foram tratados por análise de variância, teste-t e análise de regressão (p &#8804;0,05). O desempenho do dispositivo aquecedor foi medido monitorando-se a mudança de temperatura em tempo real com o auxílio de um termopar tipo-k conectado a um conversor analógico-digital. Os termopares foram colocados no aquecedor e dentro de compules de compósito. Os dados foram analisados com teste t (p &#8804;0,05). Compules (n=5) foram submetidos a um dos ciclos térmicos: Pré-aquecimento repetido (da temperatura ambiente a 60 o C, por 10 vezes) ou Prolongado (24h a 60 o C). O grau de conversão foi medido 24h após os ciclos, com o compósito à temperatura ambiente, seguindo o protocolo descrito acima. Os dados foram tratados por análise de variância e teste de Tukey (p&#8804;0,05). O aumento da temperatura intrapulpar foi medido por um termopar colocado na câmara pulpar de um prémolar contendo uma cavidade de Classe V (com 1mm de espessura de dentina remanescente). O preparo foi preenchido com compósito à temperatura ambiente ou pré-aquecido enquanto a temperatura intrapulpar era continuamente monitorada (n=5). Os dados foram comparados por análise de variância e teste de Tukey (p &#8804;0,05). Para a medida da variação de temperatura in vivo, foram feitos preparos cavitários de 2mm de profundidade em dentes posteriores de um indivíduo (n=3). Uma sonda que mensurava a temperatura foi introduzida no dente preparado em cada procedimento restaurador e durante a inserção da resina composta à temperatura ambiente ou pré-aquecida a 60°C. Os dados foram comparados com análise de variância e teste de Tukey (p &#8804;0,05). Os resultados indicaram que: 1) o pré-aquecimento da resina composta anterior à fotoativação aumenta o grau de conversão, reduz o tempo de fotoativação e resulta em maior taxa de conversão, sem alterar o tempo em que a taxa máxima ocorre; 2) tanto o dispositivo aquecedor quanto os compules atingiram temperaturas inferiores das determinadas pelo fabricante; ao remover o compósito do aquecedor a perda de calor é acentuada ; 3) o grau de conversão não foi afetado por ciclos repetidos e prolongados de pré-aquecimento da resina composta; 4) não houve aumento da temperatura intrapulpar ao serem comparadas as resinas composta à temperatura ambiente e pré-aquecida; 5) a medida da temperatura in vivo revelou que o compósito pré-aquecido a 60 o C fica somente 8 o C acima da temperatura intrabucal; a técnica de pré-aquecimento deve ser usada com cautela. / This work examined multiple aspects of pre-heating dental resin composite prior to light-curing: the monomer conversion and polymerization kinetics as a function of cure temperature, light-exposure duration and depth; the performance of the heating device (maximum temperature, thermal stability of device and temperature change when pre-heating compules); and clinically relevant issues (the effect of repeated and extended pre-heating cycles on conversion; in vitro intrapulpal temperature change and in vivo temperature change when using either room-temperature or pre-heated composite). Monomer conversion and kinetic parameters were determined using FTIR-ATR. Specimens were cured for 5, 10, 20 or 40s between 3 o and 60 o C. Real-time monomer conversion, maximum conversion rate, time into exposure when maximum rate occurred, and conversion at maximum rate were calculated. Data were analyzed using regression analysis, Student's t-tests, and ANOVA with appropriate post-hoc tests (alpha = 0.05). Performance of the heating device was measured by monitoring the real-time temperature change with a K-type thermocouple connected to an analog-to-digital converter. Thermocouples were placed both in the heater and inside composite compules. Data were analyzed using Student t-test (alpha = 0.05). Compules (n=5) were submitted to one of the temperatures cycles: Repeated (from room temperature to 60 o C, 10 times) or Extended pre-heating (24h at 60 o C). Monomer conversion was measured 24h after cycling, with composite at room temperature, following the protocol described above. Data were analyzed using ANOVA and the Tukey-Kramer post-hoc test (alpha = 0.05). Intrapulpal temperature rise was measured by placing a K-type thermocouple in the pulp chamber of a extracted, human premolar, which had a Class V preparation (1mm remaining dentin thickness). The preparation was filled using composite either at room-temperature, or pre-heated while continuously monitoring intrapulpal temperature (n=5). Data were compared using ANOVA and the Tukey-Kramer post-hoc test (&#945; =0.05). For measurement of temperature change in vivo, 2mm deep preparations were made on posterior teeth of a live human subject (n=3). Temperature values were recorded by placing a custom-made probe on the tooth preparation after each restorative procedure and during insertion of resin-composite at room temperature or pre-heated to 60°C. Data were compared using a 2-way ANOVA, and Tukey-Kramer post-hoc test (&#945; =0.05). Results indicated that: 1) pre-warming composite prior to polymerization results in greater conversion, requires shorter exposure duration, and enhances maximal rate of conversion without changing the time into the exposure when the maximum rate occurs; 2) either the heating device or the compules achieved lower temperatures than those stated by the manufacturer; composite temperature loss upon removal from the heater was dramatic; 3) neither repeated nor extended pre-heating of composites significantly affected monomer conversion values; 4) no increase in intrapulpal temperature values was observed when comparing room temperature and pre-heated composite; 5) temperature measurement in vivo revealed that composite pre-heated to 60°C attains only 8 o C above intraoral temperature upon delivery; thus, the composite pre-heating technique should be used with caution.
57

Efeito in situ do clareamento caseiro e subseqüentes tratamentos de superfície na cor e rugosidade superficial de resinas compostas / In situ effect of home bleaching and subsequent surface treatment on color and surface roughness of composite resins

Garcia, Lourdes Maria González 13 April 2012 (has links)
Este estudo avaliou in situ a susceptibilidade ao manchamento de duas resinas compostas Z350 XT® (M1) e Z250® (M2), ambas da 3M/ESPE por meio da alteração de cor e rugosidade superficial após o uso do agente clareador peróxido de carbamida 16% e subseqüentes tratamentos de superfície. Foram confeccionados 156 corpos-de-prova, n=13 para cada condição experimental. O estudo crossover teve duas fases de 14 dias cada, com um período de washout de 9 dias. Os corpos de prova de cada material foram montados em placas de acetato, distribuídos em 13 voluntários, na região dos segundos pré-molares, primeiros e segundos molares superiores e instalados nos participantes para a realização do tratamento proposto em cada fase. De acordo com aleatorização, 6 voluntários utilizaram na primeira fase do experimento o gel a base de peróxido de carbamida 16% (Home Peroxide, DMC) (CCL) e 7 voluntários o gel placebo (DMC) (SCL) da mesma composição do gel original, porém sem adição do peróxido. Os voluntários aplicaram os géis nos corpos-deprova por 8h/dia, durante 14 dias nas duas fases do experimento. Após o clareamento os corpos de prova foram submetidos aos seguintes tratamentos de superfícies: polimento com discos Sof Lex (3M/ESPE) (TR1), sem tratamento de superfície (TR2) e a aplicação do selante de superfície Biscover (BISCO) (TR3) e subseqüentemente foram imersos em vinho tinto. As leituras de cor foram realizadas 24 horas após o clareamento (L0) e 24 horas após tratamento de superfície e manchamento (L1), já para a rugosidade superficial foram realizadas 3 leituras: 24 horas após a confecção dos corpos-de-prova (L0), 24 horas após o clareamento (L1) e 24 horas após tratamento de superfície e manchamento (L2). Os dados foram submetidos ao teste ANOVA e Tukey. Os resultados mostraram que: a) O Clareamento não determinou diferença estatisticamente de &Delta;E*, no entanto, foi significante para &Delta;L*, &Delta;a* e &Delta;b*; b) A resina M1 apresentou maior média de &Delta;E* que a M2; c) Os tratamentos de superfície com Sof Lex e Biscover apresentaram valores de &Delta;E* estaticamente semelhantes, enquanto que o sem tratamento apresentou diferença estatisticamente significante entre os materiais; d) O clareamento não teve efeito significante na rugosidade superficial de resinas estudadas; e) M1 e M2 apresentaram maior rugosidade superficial em L2 que em L0 e L1; f) TR3 apresentou maior média de rugosidade superficial que TR1 e TR2. Conclui-se que: a resina Z350 XT apresentou maior alteração de cor que a Z250; o clareamento aplicado no tempo estabelecido neste estudo não promoveu alteração de cor e não influenciou na rugosidade superficial nas resinas compostas estudadas; e as resinas compostas estudadas apresentaram maior rugosidade após o Tratamento de superfície associado ao manchamento com vinho tinto; o selante de superfície Biscover apresentou maior rugosidade superficial para a resina Z250. / This study evaluated in situ the staining susceptibility of different composite resins (Z350 XT ® (M1) and Z250 ® (M2), both of 3M/ESPE) by color change and surface roughness after the aplication of 16% carbamide peroxide bleaching gel and subsequent surface treatments and staining with red wine. One hundred fifty-six specimens were fabricated where n=13 were per experimental condition. The study had two phases of 14 days each, with a washout period of 9 days between them. The specimens of each material fixed into custom fabricated trays in 13 volunteers in the region of the second premolars, first and second molars and installed in the participants to carry out for the proposed treatment at each stage. According randomly 6 volunteers used in the first stage of the experiment the 16% peroxide carbamide gel (Home Peroxide, DMC) (CCL) and 7 volunteers used placebo gel (DMC) (SCL) that it was the same composition original gel, but without addition of peroxide. The volunteers applied the gel on the top of the specimens for 8h/day for 14 days during the two phases of the experiment. After bleaching treatment the specimens were subjected to the following surface treatments: polishing with Sof Lex (3M/ESPE) (TR1), without surface treatment (TR2) and the application of the sealant surface Biscover (BISCO) (TR3) and subsequently were immersed in red wine. In the second phase of the experiment, the specimens were replaced by others and the volunteers were crossed on the gel, so that all used both gels. Finishing the second phase, the specimens were subjected to surface treatment and subsequent staining. The color change were measured 24 hours after bleaching in situ (L0) and 24 hours after surface treatment and red wine stains (L1) and the surface roughness were measured immediately after 24 hours of preparation of the specimens (L0) 24 hours after the in situ bleaching treatment (L1) and 24 hours after surface treatment and staining with red wine (L2). Data were submitted to ANOVA and Tukey. The results showed that: a) The bleaching showed no statistically significant difference for &Delta;E *, however, was significant for all parameters &Delta;L*, &Delta;a* and &Delta;b*; b) The composite 350 XT presented higher average of color change (&Delta;E * ) than Z250; c) The surface treatments with Sof Lex and Biscover had values of &Delta;E* statistically similar, while no treatment surface showed a statistically significant difference between the materials; d) Bleaching had no significant effect on surface roughness of composite resins; e) The composites showed higher values of surface roughness in L2 than in L1 and L0. f) TR3 demonstrated higher average of surface roughness than TR1 and TR2. It was concluded that bleaching did not affect the color change and surface roughness in the composites studied, the surface treatment had no effect clinically significant for the susceptibility to staining, and the composites studied had higher surface roughness when subjected to treatment surface staining associated with red wine and the surface sealant Biscover showed higher surface roughness for resin Z250.
58

Efeito in situ do clareamento caseiro e subseqüentes tratamentos de superfície na cor e rugosidade superficial de resinas compostas / In situ effect of home bleaching and subsequent surface treatment on color and surface roughness of composite resins

Lourdes Maria González Garcia 13 April 2012 (has links)
Este estudo avaliou in situ a susceptibilidade ao manchamento de duas resinas compostas Z350 XT® (M1) e Z250® (M2), ambas da 3M/ESPE por meio da alteração de cor e rugosidade superficial após o uso do agente clareador peróxido de carbamida 16% e subseqüentes tratamentos de superfície. Foram confeccionados 156 corpos-de-prova, n=13 para cada condição experimental. O estudo crossover teve duas fases de 14 dias cada, com um período de washout de 9 dias. Os corpos de prova de cada material foram montados em placas de acetato, distribuídos em 13 voluntários, na região dos segundos pré-molares, primeiros e segundos molares superiores e instalados nos participantes para a realização do tratamento proposto em cada fase. De acordo com aleatorização, 6 voluntários utilizaram na primeira fase do experimento o gel a base de peróxido de carbamida 16% (Home Peroxide, DMC) (CCL) e 7 voluntários o gel placebo (DMC) (SCL) da mesma composição do gel original, porém sem adição do peróxido. Os voluntários aplicaram os géis nos corpos-deprova por 8h/dia, durante 14 dias nas duas fases do experimento. Após o clareamento os corpos de prova foram submetidos aos seguintes tratamentos de superfícies: polimento com discos Sof Lex (3M/ESPE) (TR1), sem tratamento de superfície (TR2) e a aplicação do selante de superfície Biscover (BISCO) (TR3) e subseqüentemente foram imersos em vinho tinto. As leituras de cor foram realizadas 24 horas após o clareamento (L0) e 24 horas após tratamento de superfície e manchamento (L1), já para a rugosidade superficial foram realizadas 3 leituras: 24 horas após a confecção dos corpos-de-prova (L0), 24 horas após o clareamento (L1) e 24 horas após tratamento de superfície e manchamento (L2). Os dados foram submetidos ao teste ANOVA e Tukey. Os resultados mostraram que: a) O Clareamento não determinou diferença estatisticamente de &Delta;E*, no entanto, foi significante para &Delta;L*, &Delta;a* e &Delta;b*; b) A resina M1 apresentou maior média de &Delta;E* que a M2; c) Os tratamentos de superfície com Sof Lex e Biscover apresentaram valores de &Delta;E* estaticamente semelhantes, enquanto que o sem tratamento apresentou diferença estatisticamente significante entre os materiais; d) O clareamento não teve efeito significante na rugosidade superficial de resinas estudadas; e) M1 e M2 apresentaram maior rugosidade superficial em L2 que em L0 e L1; f) TR3 apresentou maior média de rugosidade superficial que TR1 e TR2. Conclui-se que: a resina Z350 XT apresentou maior alteração de cor que a Z250; o clareamento aplicado no tempo estabelecido neste estudo não promoveu alteração de cor e não influenciou na rugosidade superficial nas resinas compostas estudadas; e as resinas compostas estudadas apresentaram maior rugosidade após o Tratamento de superfície associado ao manchamento com vinho tinto; o selante de superfície Biscover apresentou maior rugosidade superficial para a resina Z250. / This study evaluated in situ the staining susceptibility of different composite resins (Z350 XT ® (M1) and Z250 ® (M2), both of 3M/ESPE) by color change and surface roughness after the aplication of 16% carbamide peroxide bleaching gel and subsequent surface treatments and staining with red wine. One hundred fifty-six specimens were fabricated where n=13 were per experimental condition. The study had two phases of 14 days each, with a washout period of 9 days between them. The specimens of each material fixed into custom fabricated trays in 13 volunteers in the region of the second premolars, first and second molars and installed in the participants to carry out for the proposed treatment at each stage. According randomly 6 volunteers used in the first stage of the experiment the 16% peroxide carbamide gel (Home Peroxide, DMC) (CCL) and 7 volunteers used placebo gel (DMC) (SCL) that it was the same composition original gel, but without addition of peroxide. The volunteers applied the gel on the top of the specimens for 8h/day for 14 days during the two phases of the experiment. After bleaching treatment the specimens were subjected to the following surface treatments: polishing with Sof Lex (3M/ESPE) (TR1), without surface treatment (TR2) and the application of the sealant surface Biscover (BISCO) (TR3) and subsequently were immersed in red wine. In the second phase of the experiment, the specimens were replaced by others and the volunteers were crossed on the gel, so that all used both gels. Finishing the second phase, the specimens were subjected to surface treatment and subsequent staining. The color change were measured 24 hours after bleaching in situ (L0) and 24 hours after surface treatment and red wine stains (L1) and the surface roughness were measured immediately after 24 hours of preparation of the specimens (L0) 24 hours after the in situ bleaching treatment (L1) and 24 hours after surface treatment and staining with red wine (L2). Data were submitted to ANOVA and Tukey. The results showed that: a) The bleaching showed no statistically significant difference for &Delta;E *, however, was significant for all parameters &Delta;L*, &Delta;a* and &Delta;b*; b) The composite 350 XT presented higher average of color change (&Delta;E * ) than Z250; c) The surface treatments with Sof Lex and Biscover had values of &Delta;E* statistically similar, while no treatment surface showed a statistically significant difference between the materials; d) Bleaching had no significant effect on surface roughness of composite resins; e) The composites showed higher values of surface roughness in L2 than in L1 and L0. f) TR3 demonstrated higher average of surface roughness than TR1 and TR2. It was concluded that bleaching did not affect the color change and surface roughness in the composites studied, the surface treatment had no effect clinically significant for the susceptibility to staining, and the composites studied had higher surface roughness when subjected to treatment surface staining associated with red wine and the surface sealant Biscover showed higher surface roughness for resin Z250.
59

Efeito do retardamento da polimerização da base de cimento de ionômero de vidro modificado por resina na resistência adesiva em restaurações de resina composta / Effect of delaying photoativation of resin modified glass-ionomer cement used as a liner on the bond strength of composite resin restorations

Casas Apayco, Leslie Caroll 22 April 2009 (has links)
Durante o processo inicial da reação de presa, o cimento de ionômero de vidro modificado por resina (CIVMR) apresenta baixo módulo de elasticidade, característica importante quando utilizado como base de restaurações com resina composta, por diminuir o estresse de contração de polimerização nas paredes cavitárias. O presente estudo teve como objetivo analisar a influência da técnica de polimerização de uma base CIVMR (VitrebondTM) por resina na interface dente/restauração de resina composta, através de teste de microtração e análise em microscopia confocal. Foram utilizados 30 dentes molares humanos hígidos extraídos, nos quais foram confeccionadas cavidades padronizadas em sua face oclusal (5mm de comprimento x 3mm de largura x 4,5mm profundidade). O sistema adesivo utilizado AdperTM Single Bond 2 foi marcado previamente com Rodamina B (0,16mg/ml), para possibilitar a análise em microscópio confocal. Os dentes foram divididos em 3 grupos: Grupo 1 (controle): base de CIVMR VitrebondTM + fotoativação + sistema adesivo + resina composta FiltekTM Z250; Grupo 2: base de CIVMR VitrebondTM + sistema adesivo + fotoativação por 30 segundos simultânea dos dois materiais + resina composta FiltekTM Z250; Grupo 3: base de CIVMR por resina VitrebondTM + tempo de espera de 60 segundos + fotoativação + sistema adesivo + resina composta FiltekTM Z250. Após a restauração, os dentes permaneceram em água deionizada em estufa a 37 ºC por 24 horas. Em seguida, foram seccionados com disco de diamante em fatias de aproximadamente 0,8mm no sentido vestíbulo-lingual. Uma fatia de cada dente foi separada aleatoriamente para análise da presença de fendas na interface dentina/resina composta em microscopia confocal. As demais fatias foram seccionadas para a confecção de palitos, para os testes de microtração. Os resultados de resistência de união foram submetidos à análise de variância a um critério ANOVA a 5% e teste de qui-quadrado para as variáveis de presença de fendas marginais e tipo de fratura resultante (p<0,05). Não houve diferença estatisticamente significante entre os três grupos (p=0,644) com relação à resistência adesiva e tipo de fratura, predominando a fratura do tipo adesiva para todos os grupos. Quanto à presença de fendas marginais internas, foi evidenciada sua presença nos grupos 2 e 3, sem diferença estatisticamente significante entre os três grupos testados (p=0,082). Conclui-se, portanto, que a técnica de polimerização da base de cimento de ionômero de vidro modificado por resina não influencia na resistência adesiva da interface dente/restauração de resina composta. / During the initial process of setting reaction, the resin-modified glass-ionomer cement (RMGIC) shows low modulus of elasticity, which is an important characteristic when RMGIC is used as a liner in resin composites restorations, because it decreases the polymerization shrinkage stress in cavity walls. The aim of this study was to analyze the influence of polymerization techniques of resin-modified glass-ionomer cement used as a liner on the adhesive interface dentin/resin by microtensile test and confocal microscopic analysis. Standardized occlusal cavity preparations (5mm length x 3mm wide x 4.5mm depth) were prepared in 30 human extracted molars. For the analysis at the confocal microscope, the adhesive system AdperTM Single Bond 2 was previously marked with rodhamine B (0.16mg/ml). The tooth were divided into three groups: Group 1 (control): RMGIC liner VitrebondTM + photoactivation for 30 seconds + adhesive system + resin composite Filtek TM Z250; Group 2: RMGICs liner VitrebondTM + adhesive system + simultaneous photoactivation of both materials + resin composite FiltekTM Z250; Group 3: RMGICs liner VitrebondTM+ 60 seconds delay time + photoativation for 30 seconds + adhesive system + resin composite FiltekTMZ250. Specimens were stored at 37ºC in deionized water for 24 hours. After this period, tooth was sectionated in 0.8mm slices (buco-lingual). One slice of each tooth was randomly selected for confocal microscopy for analysis of the interface resin/dentin. The other slices were sectionated in sticks (mesio-distal) for microtensile test. One-way ANOVA (p<0.05) showed no significant statistical difference among groups 1, 2 and 3 (p=0.644). Quisquare test showed no significant statistical difference of type of fracture (adhesive fracture was predominant) and presence of gap at the interface dentin/resin among groups. (p=0.082). It can be concluded, that polymerization technique of resin-modified glassionomer cement (RMGIC) did not influence bond strength and dentin/resin composite interface.
60

Efeito da base de cimento de ionômero de vidro convencional e modificado por resina na interface adesiva dente/resina composta após termociclagem / Effect of conventional and resin-modified glass ionomer cements base on tooth/composite resin adhesive interface after termocycling

Sampaio, Paula Costa Pinheiro 24 April 2009 (has links)
Resinas compostas apresentam contração de polimerização e a tensão gerada durante essa polimerização compete com a força adesiva na interface dente/restauração. A técnica incremental e o uso de bases com alta resiliência e módulo de elasticidade próximo ao das estruturas dentárias são técnicas desenvolvidas para tentar diminuir a tensão originada pela contração de polimerização. O presente estudo teve como objetivo analisar a influência do uso de bases de cimento de ionômero de vidro convencional e modificado por resina na qualidade e adaptação marginal na interface dentina/resina composta, após a ciclagem térmica, usando testes de resistência adesiva e análise em microscopia confocal de varredura a laser. Foram confeccionadas cavidades na face oclusal (4,5mm x 3mm x 5mm) de 60 molares humanos extraídos divididos em 6 grupos: 1 e 4 - sistema adesivo (AdperTM Single Bond; 3M ESPE) + resina composta (Filtek Z250; 3M ESPE); 2 e 5 - base de cimento de ionômero de vidro convencional (Ketac Molar Easymix; 3M ESPE) + sistema adesivo + resina composta; e 3 e 6 - base de cimento de ionômero de vidro modificado por resina (Vitrebond; 3M ESPE) + sistema adesivo + resina composta. Os grupos 4, 5 e 6 sofreram um processo de termociclagem com dois banhos (5ºC 55ºC) durante 30 segundos em 5.000 ciclos. Após 24 horas, os dentes foram seccionados em uma máquina de cortes com disco de diamante em espessura de 0,8mm. Uma fatia de cada dente foi separada aleatoriamente para análise em Microscópio Confocal para observação e mensuração de possíveis fendas marginais internas. As demais fatias foram seccionadas para a confecção de palitos (0,8mm X 0,8mm) que foram submetidos a testes de microtração em uma máquina de ensaios universal EMIC. Os resultados de resistência adesiva foram submetidos à análise de variância a um critério (ANOVA) e ao teste t-Student (p< 0,05). A presença de fendas foi avaliada com o teste da razão de verossimilhança ou teste exato de Fisher e os valores de comprimento das fendas foram avaliados pelo teste não paramétrico de Kruskal-Wallis (p<0,05). Não foram observadas diferenças estatisticamente significantes na resistência adesiva em nenhum dos grupos sem termociclagem (G1 19,28 MPa; G2 16,29 MPa; e G3 15,95MPa) ou com termociclagem (G4 19,74 MPa; G5 16,58 MPa; e G6 16,01 MPa). A análise das medidas das fendas revelou não haver diferença estatisticamente significante entre os grupos G1 (1,4µm), G2 (2,88µm) e G3 (4,63µm) e entre os grupos G4 (4,2µm), G5 (12,5µm) e G6 (5,4µm). No entanto, a termociclagem determinou um aumento do tamanho médio das fendas no grupo com base de CIV convencional (G4 12,5µm). A análise da presença ou ausência de fendas mostrou um aumento na porcentagem do número de fendas quando os espécimes foram termociclados, para os grupos sem base e com base de CIV (G1 - 30%; G2 - 25% G3 25%; G4 - 53,33%; G5 70%; e G6 30%). Os resultados mostraram, ainda, não haver relação entre o comprimento e a formação das fendas com a resistência adesiva. Conclui-se, portanto, que o uso de base de cimento de ionômero de vidro modificado por resina mantém mais estável a qualidade da interface adesiva dentina/resina composta após envelhecimento artificial com termociclagem. / Polymerization shrinkage leads to a tension into dentin/resin composite interface that can cause marginal discoloration, poor marginal adaptation, secondary caries and post-operative sensitivity. The incremental restorative technique and the use of a resilient liner with a modulus of elasticity similar to dental structures are techniques used to decrease the shrinkage polymerization tension. The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the adhesive interface dentin/resin of occlusal restorations after thermocycling aging. Occlusal cavities were prepared sixty human extracted molars, divided into six groups: 1 and 4 with no liner; 2 and 5 glass-ionomer cement (Ketac Molar Easymix); and 3 and 6 resin-modified glass-ionomer cement (Vitrebond). Resin composite (Filtek Z250) was placed after application of adhesive system Adper Single Bond 2. Adhesive system was mixed with fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. After that, the specimens of groups 4, 5, 6 were thermocycled into 2 baths (5ºC 55ºC) of 30s each in 5.000 cycles. After this period, teeth were sectioned in 0,8mm slices. One slice of each tooth was randomly selected for analysis in Confocal Microscopy. The other ones were sectioned in sticks, which were submitted to micro-tensile test. The results of adhesive strength were analyzed by one way ANOVA and t-Student tests. Gap formation were analysed by Fisher test and the gaps size were analyzed by Kruskal-Wallis test (p<0,05). No statistical difference on adhesive resistance was showed between groups. Confocal Microscopy analysis showed gaps with a higher mean sizes for group 4 (12,5µm) and higger percentage of marginal gaps formation for the thermocycled groups (G1 - 30%; G2 - 25%; G4 - 53,33%; G5 70%). Groups 3 (25%) and 6 (30%) showed the lowest percentage of marginal gap formation. The results revealed that gap formation is not related to adhesive strength. It can be concluded, therefore, that the use of a resin-modified-glassionomer cement liner showed less gap formation on dentin/composite adhesive interface after artificial aging compared to conventional glass ionomer cement liner and restorations with no lining.

Page generated in 0.0851 seconds