• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • Tagged with
  • 49
  • 49
  • 43
  • 42
  • 19
  • 14
  • 14
  • 14
  • 11
  • 11
  • 10
  • 10
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência da delimitação da área adesiva no ensaio mecânico de microcisalhamento / Evaluation of adhesive area delimitation on microshear test

Angela Mayumi Shimaoka 26 June 2007 (has links)
Este estudo teve como objetivos avaliar se a delimitação da área adesiva a ser testada no ensaio mecânico de microcisalhamento é capaz de alterar os resultados de resistência de união obtidos; determinar se a delimitação da área adesiva do ensaio mecânico de microcisalhamento pode alterar o ranqueamento dos sistemas adesivos analisados e correlacionar os tipos de fratura encontrados com valores de resistência adesiva obtidos em cada um dos grupos experimentais. As unidades experimentais foram confeccionadas sobre 18 superfícies de dentina obtidas a partir de incisivos bovinos distribuídas aleatoriamente em 3 grupos, segundo o sistema adesivo a ser utilizado (Adper Single Bond 2, Clearfil Se Bond, Clearfil S3 Bond). Desta forma foram compostos 6 grupos experimentais segundo os dois fatores de variação a serem estudados: sistema adesivo e delimitação da área adesiva. Sobre cada superfície dentinária foram confeccionados 4 cilindros em resina composta, sendo 2 com delimitação da área adesiva e 2 sem a delimitação desta área, totalizando n=12. Após 24 horas de armazenamento os espécimes foram submetidos ao ensaio mecânico de microcisalhamento. O teste estatístico ANOVA (p<0,01) e o teste auxiliar de Tukey determinaram que todos os grupos experimentais em que a delimitação da área adesiva foi realizada apresentaram menores valores de resistência adesiva quando comparados aos seus respectivos grupos controle (sem delimitação da área adesiva). Para os grupos em que não foi realizada a delimitação da área não foram observadas diferenças estatisticamente significantes entre os adesivos empregados. Em contrapartida, quando não foi realizada a delimitação, o sistema adesivo Clearfil S3 Bond mostrou maiores valores de resistência adesiva quando comparado aos sistemas Adper Single Bond 2 e Clearfil SE Bond, que por sua vez não se mostraram estatisticamente diferentes entre si. Concluiu-se que a delimitação da área adesiva no ensaio de microcisalhamento alterou os resultados de resistência adesiva obtidos, e que a modificação da metodologia do ensaio mecânico de microcisalhamento foi capaz de alterar o ranqueamento dos sistemas adesivos analisados. / This study had as objectives to evaluate if the delimitation of adhesive area on microshear test is capable to modify the values of shear bond strength; to determine if this delimitation can modify the ranking of the analyzed adhesive systems and to correlate the found types of failure with the values of bond strength in each experimental group. The specimens were confectioned on 18 incisors bovine dentine surfaces randomly distributed into 3 groups, according to adhesive system used (Adper Single Bond 2, Clearfil If Bond, Clearfil S3 Bond). In such a way, 6 experimental groups were designed according to two factors of variation to be studied: adhesive system and delimitation of the adhesive area. Over each dentin surface were confectioned 4 composite resin cylinders, being 2 with delimitation of the adhesive area and 2 without the delimitation of this area, totalizing n=12. After 24 hours of storage the specimens were submitted to microshear test Statistical test ANOVA (p<0,01) and Tukey?s test determined that all the experimental groups where the delimitation of the adhesive area was carried through presented lesser values of shear bond strength when compared with its respective control groups (without delimitation of adhesive area). Groups without area delimitation did not been demonstrate statistical significant differences between adhesives. On the other hand, when such delimitation was not carried through, the adhesive system Clearfil S3 Bond demonstrates greater values of shear bond strength compared to Adper Single 2 Bond and Clearfil SE Bond, which did not showed statistical difference between them. It was concluded that the delimitation of the adhesive area in the microshear test altered the obtained results of adhesive resistance, and that the modification of microshear test methodology was capable to modify the ranking of the analyzed adhesive systems.
22

Resistência de união e da microinfiltração marginal em restaurações fotopolimerizadas com LED e luz halógena associadas a três modos de aplicação de um sistema adesivo universal: estudo in vitro / Bond strength and marginal microleakage restorations cured with LED and halogen dental curing light associated to three modes of application of a universal adhesive system: in vitro study

Ricardi, Felipe de Brum 02 March 2017 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-04-13T17:05:10Z No. of bitstreams: 2 Felipe_Ricardi2017.pdf: 1032662 bytes, checksum: 6aaca7ee5122dd1349c2efde06964976 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-04-13T17:05:10Z (GMT). No. of bitstreams: 2 Felipe_Ricardi2017.pdf: 1032662 bytes, checksum: 6aaca7ee5122dd1349c2efde06964976 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objective was to evaluate the bond strength and marginal microleakage in composite resin restorations, using Universal Single Bond adhesive system associated with Ultralux (halogen) and Bluephase (LED) photoactivators. For bond strength, eighty healthy human third molars were divided: Halogen (n = 40); LED (n = 40), subdivided according to the technique of application of the adhesive system: self-etch – enamel; etch-and-rinse – enamel, self-etch – dentin; etch-and-rinse – dentin. The teeth were submitted to the Tensile Bond Strength test and the fracture pattern was observed under an optical microscope - 40X magnification, analyzed by the ANOVA, Tukey and Fisher tests (5%). For the marginal microleakage assay, 120 class II cavities were prepared in sixty healthy, randomly divided third human molars: Halogen (n = 30); LED (n = 30) and subdivided according to the application technique of the adhesive system: self-etch; selective-etch; etch-and-rinse. The teeth were thermocycled 2000 times (± 5 / 55ºC), stained in 5% basic fuchsin and sectioned for qualitative and quantitative evaluations, analyzed by the Kruskall-Wallis and Dunn tests (5%). For bond strength in enamel and dentin, the adhesive application with prior acid etching was better than the etch-and-rinse (p <0.0001), regardless of the type of photoactivator used (p <0.05). The self-etch showed the lowest values of microleakage, (p <0.0001). The self-etch, obtained the best results in relation to the other techniques of application of the adhesive system in both tests, regardless of the type of photoactivating apparatus. / O objetivo foi avaliar a resistência de união e microinfiltração marginal em restaurações de resina composta, utilizando sistema adesivo Single Bond Universal associado com fotoativadores Ultralux (halógeno) e Bluephase (LED). Para resistência de união, oitenta terceiros molares humanos hígidos foram divididos: Halógena (n=40); LED (n=40), sendo subdivididos de acordo com a técnica de aplicação do sistema adesivo: condicionamento total-esmalte; autocondicionante-esmalte; condicionamento total-dentina; autocondicionante-dentina. Os dentes foram submetidos ao teste de microtração e o padrão de fratura foi observado em microscópio ótico – 40X de aumento, analisadas pelos testes ANOVA, Tukey e Fisher (5%). Para o ensaio de microinfiltração marginal, 120 cavidades classe II foram preparadas em sessenta terceiros molares humanos hígidos, aleatoriamente divididos: Halógena (n=30); LED (n=30) e subdivididos de acordo com a técnica de aplicação do sistema adesivo: condicionamento total; condicionamento seletivo; autocondicionante. Os dentes foram termociclados 2000 vezes (±5/55ºC), corados em fucsina básica 5% e seccionados para avaliações qualitativa e quantitativa, analisados pelos testes Kruskall-Wallis e Dunn (5%). Para resistência de união em esmalte e dentina, a aplicação do adesivo com condicionamento ácido prévio, foi melhor que o autocondicionante (p<0.0001), independentemente do tipo de fotoativador utilizado (p<0.05). O condicionamento total mostrou os menores valores de microinfiltração, (p<0.0001). O condicionamento total, obteve os melhores resultados em relação às outras técnicas de aplicação do sistema adesivo em ambos os testes, independentemente do tipo de aparelho fotoativador.
23

Influência do condicionamento da dentina na resistência de união de cimento de ionômero de vidro / Er,Cr:YSGG Laser Dentin Conditioning Influence on Glass Ionomer Cement Bond Strength

Garbui, Bruna Uglik 05 July 2012 (has links)
Objetivos: avaliar o efeito de 3 parâmetros de condicionamento da dentina utilizando o laser de Er,Cr;YSGG (2,78m) na resistência de união (RU) de cimento de ionômero de vidro convencional (CIV). Materiais e métodos: Foram utilizados neste estudo 68 terceiros molares humanos, divididos aleatoriamente em 4 grupos (n=17/ grupo): G1 (grupo controle): nenhum tipo de condicionamento; G2: condicionamento com laser de Er,Cr;YSGG 0,5W, 25mJ, 20Hz ou G3: 1,0W, 50mJ, 20Hz e G4: 1,5W, 75mJ, 20Hz. Dois dentes em cada um dos grupos foram observados em microscopia eletrônica de varredura (MEV) para identificar as características morfológicas dos diferentes condicionamentos de superfície realizados. Os outros 15 dentes/grupo, foram preparados para ensaio de RU, obtendo uma superfície plana de dentina onde foram construídos 3 (n=45/grupo) corpos de prova em forma de cilindro (1mm de diâmetro X 0,5mm de altura) utilizando o ionômero de vidro Ketac Molar Easymix- 3M ESPE. Após o armazenamento em água destilada por 24h a 37oC os espécimes foram ensaiados pelo teste de microcisalhamento. Os valores finais de resistência adesiva foram calculados e expressos em Mega Pascal (MPa). Os dados foram coletados e analisados por ANOVA (p<0,001). Resultados: Os espécimes do G2 apresentaram os maiores resultados de RU (10,50MPa ±0,84), seguido pelo G1 (4.77MPa ±0.59), G3 (3.32MPa ±0.39) e G4 (2,94MPa ±0,50) que não apresentaram diferença estatisticamente significante quanto comparados entre si. A análise em MEV do G1 mostrou camada de smear ao longo de toda a superfície de dentina, enquanto nos outros grupos observou-se túbulos dentinários abertos, característicos na irradiação com laser de Er,Cr:YSGG. Os pulsos do laser no G2 eram facilmente distinguidos, o que não acontecia nos grupos G3 e G4, sugerindo que parâmetros de energia maiores podem causar efeitos mais extensos à estrutura da dentina. Na análise do padrão de fratura, todos os grupos apresentaram maior porcentagem de fratura adesiva G1:73,3%, G2:48,9% G3:66,7% e G4:64,4%. O tipo de fratura mista foi proporcional ao aumento da RU (G1:24,4%, G2:46,7%, G3:20,0% e G4:17,8%). Conclusão: O condicionamento da dentina com o laser de Er,Cr:YSGG na potência de 0,5W aumentou significativamente a RU do CIV à dentina, enquanto os demais parâmetros testados reduziram a RU. / Objective: To evaluate the effect of 3 dentin conditioning parameters of Er,Cr:YSGG laser (2,78 m) on the bond strength (BS) of conventional glass ionomer cement (CGIC). Methods: A total of 68 third molars were divided into four groups and was subjected to one of the following pretreatments: G1- the control group, no pretreatment was realized; G2, G3 and G4 were pretreated with Er,Cr:YSGG laser irradiation at 0.5 W, 25 mJ, 9 J/cm2, and 20 Hz (G2); 1.0 W, 50 mJ, 18 J/cm2, and 20 Hz (G3); and at 1.5 W, 75 mJ, 27 J/cm2, and 20 Hz (G4). A scanning electron microscopy (SEM) evaluation (n=2) of pretreated dentine and a microshear bond strength test (n=15) were performed after 24h of water immersion. To build the specimens (each of which was 1 mm in diameter) for the microshear test, CGIC (Ketac Molar Easy Mix) was used. The data were analysed by one-way ANOVA (p<0.001). Results: The G2 specimens presented the highest BS results (10.50 MPa ± 0.84), and G1 had the next highest average BS values (4.77 MPa ± 0.59). G3 (3.32 MPa ± 0.39) and G4 (2.94 MPa ± 0.50) demonstrated the lowest BS values, although the BS difference between these groups was not statistically significant (p>0.001). The SEM analysis of G1 revealed that the smear layer covered the entire dentine surface, whereas in groups G2, G3, and G4, irregular dentine was detected that possessed the open dentinal tubules and protruded peritubular dentine that are the characteristic results of laser irradiation. Laser pulses could easily be distinguished in G2 but not in G3 and G4, suggesting that higher energy parameters can broadly disrupt dentine structure and thereby affect the bonding of dentine to GIC. Conclusion: Dentine pretreatment with an Er,Cr:YSGG laser at a power of 0.5 W increased the BS of conventional GIC.
24

Análise "in vitro" da resistência adesiva de sistemas adesivos autocondicionantes com o substrato dentinário após a desproteinização dentinária

Antury, José David Ruan 18 November 2005 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1 Jose David.pdf: 1396926 bytes, checksum: 7d3efdcd4df11b4c6bee44febd2ff0bb (MD5) Previous issue date: 2005-11-18 / The purpose of this study was to evaluate “in vitro” the bond strength of the self etch adhesive systems One Coat SE Bond, Self Etch Bond, and XENO®III with the dentin substrate, by means of the microtensile bond strength test, after dentin deproteinization. The conventional adhesive system Adper Single Bond™/3M™-ESPE™ was used as group control. Thirty five human integral third molars were chosen. Theirs occlusal surfaces were cut 3mm±1mm. The dentin surfaces polished with silicon carbide sandpaper of granulation 600 during 1min, in a Politriz. Each group (n=5) received its respective adhesive systems, GI: controle (hybrid layer); GII, GIV and GVI: self etch adhesive systems (reaction-integration); GIII, GV and GVII: self etch adhesive systems (deproteinization). The teeth were restored with resin composite Filtek Z-250 3M™/ESPE™. 24 hours after, the teeth were sectioned using a diamond saw mounted in a Labcut 1010 machine, to get perpendicular sections to the bonding interface with a cross-sectional area to the approximately 0,7 mm2. Were selected 3 specimens per group. Which were prepared and analyzed through the scanning electronic microscope of camp emission and the “confocal laser scanning microscope”, the remaining specimens were submitted to microtensile bond strength in an universal testing machine, at a crosshead speed of 1 mm/min. the mode of fracture was observed using a optic microscope. For each one of the self etching adhesive systems a viscosity test was accomplished. The values of bond strength were submitted to statistical analysis using the Kruskal-Wallis test. The results had shown that the self etch adhesive system XENO®III, after the deproteinization with NaOCl 5,2% (43,60±11,44 MPa) presented the higher values of bond strength. The lowest values were observed in the self etch adhesive system One Coat SE Bond with and without deproteinization (27,50±8,75 MPa) and (27,07±7,27 MPa) respectively. The Self Etch Bond with NaOCl 5,2% demonstrated higher values of bond strength. The microscopy analyses allowed to observed the differences between the adhesive interfaces gotten (hybrid layer, reaction-integration, deproteinization). By this study was possible demonstrated that the dentin deproteinization through the application of NaOCl 5,2%, not influenced on the bond strength of the self etch adhesive systems One Coat SE Bond and XENO®III. In the self etch adhesive system Self Etch Bond with NaOCl the bond strength increased significantly. / O objetivo deste trabalho foi avaliar “in vitro” a resistência adesiva dos sistemas adesivos autocondicionantes One Coat SE Bond, Self Etch Bond, e o XENO®III com o substrato dentinário, por meio do teste de microtração, após a desproteinização dentinária. O sistema adesivo convencional Adper Single Bond™/3M™-ESPE™ foi utilizado como grupo controle. Foram selecionados 35 terceiros molares humanos íntegros. As superfícies oclusais foram cortadas 3mm±1mm. As superfícies de dentina polidas com lixas de carbureto de silício de granulação 600 por 1 min., numa Politriz. Cada grupo (n=5) recebeu os respectivos sistemas adesivos GI: controle (camada híbrida); GII, GIV e GVI: sistemas adesivos autocondicionantes (reação-integração); GIII, GV e GVII: sistemas adesivos autocondicionantes (desproteinização). Os dentes foram restaurados com resina composta Filtek Z-250 3M™/ESPE™. 24 horas após, os dentes foram seccionados usando um disco de diamante montado numa máquina LABCUT 1010, e obter seções perpendiculares da interface adesiva, com uma área de seção transversal de aproximadamente 0,7 mm2 . Foram selecionados 3 espécimes por grupo, os quais foram preparados e analisados em microscópio eletrônico de varredura de emissão de campo e “confocal laser scanning microscope”, os espécimes restantes foram submetidos ao teste de microtração, numa máquina de ensaios universal, a uma velocidade de 1 mm/min. Os modos de fratura foram visualizados utilizando um microscópio óptico. Para cada um dos sistemas adesivos autocondicionantes foi realizado um teste de viscosidade. Os valores de resistência foram submetidos ao teste estatístico de Kruskal-Wallis. Os resultados mostraram que o sistema adesivo autocondicionantes XENO®III após a desproteinização com NaOCl 5,2% (43,60±11,44 MPa), apresentou os maiores valores de resistência adesiva. Os menores valores foram observados no sistema adesivo autocondicionante One Coat SE Bond com e sem desproteinização (27,50±8,75 MPa) e (27,07±7,27 MPa) respectivamente. O Self Etch Bond com NaOCl 5,2%, apresentou maiores valores de resistência adesiva. A análise de microscopia permitiu observar as diferenças entre as interfaces adesivas obtidas (camada híbrida, reação-integração, e desproteinização). Para este estudo foi possível demonstrar que, a desproteinização dentinária por meio da aplicação de NaOCl 5,2% por 40 seg., não influenciou na resistência adesiva, dos adesivos autocondicionantes One Coat SE Bond e do XENO®III. No adesivo autocondicionante Self Etch Bond com NaOCl, a resistência adesiva aumentou significativamente. Palavras-Chave: Sistemas Adesivos; Hipoclorito de sódio; Resistência Adesiva à Tração.
25

Efeito da temperatura de secagem de dois tipos de silano e da supressão ou redução do tempo de condicionamento com ácido hidrofluorídrico na resistência de união entre uma cerâmica de dissilicato de lítio e um cimento resinoso / Effect of drying temperature of two silan types and elimination or reduction of conditioning hydrofluoridric acid time with the bond strenght between a lithium disilicate ceramic and a resin cement

Leticia Monteiro Peixoto 24 August 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este estudo avaliou o efeito de diferentes métodos de silanização e aplicação do ácido hidrofluorídrico (HF) sobre a resistência à microtração de uma cerâmica de dissilicato de lítio a um cimento resinoso. Quarenta blocos de IPS e.max Press /Ivoclar Vivadent (5x5x6mm) foram cimentados a blocos de resina Z250/3M ESPE (5x5x6mm) usando o cimento resinoso RelyX ARC/3M ESPE de acordo com os seguintes métodos de tratamento superficial: G1: 20s de ácido fluorídrico (HF) + silano não hidrolisado Primer-Activactor/Dentsply (SNH) seco à temperatura ambiente; G2: 20s HF + silano pré-hidrolisado RelyX Ceramic-Primer/3M ESPE (SPH) seco à temperatura ambiente; G3: 10s HF + SNH seco com ar quente (50oC-2min); G4: 10sHF + SPH seco com ar quente (50oC-2min); G5: sem ácido, SNH seco com ar quente (50oC-2min); G6: sem ácido, SPH seco com ar quente (50oC-2min); G7: sem ácido, SNH seco à temperatura ambiente; G8: sem ácido, SPH seco à temperatura ambiente. Antes de cada método de silanização, os blocos cerâmicos receberam acabamento com lixas de carbeto de silício (220-600) e limpeza com ácido fosfórico 37% (1min). A cimentação foi realizada com carga vertical de 1kg por 10min. Os conjuntos de cerâmica/cimento/resina foram armazenados em água destilada (37C) por 24 horas e depois seccionados em máquina de corte Isomet 1000 a fim de obter palitos (n = 40) de 1mm2 de área da seção transversal, que foram submetidos ao teste de microtração em máquina de ensaio universal Emic (v = 0,5mm/min). O modo de fratura foi avaliado em microscópio eletrônico de varredura. A análise estatística foi realizada utilizando ANOVA / Dunnett (p-valor = 0,000). As médias MPa e desvio padrão foram: G1-21,5 (8,9) BC; G2-30,5 (7,2) A; G3-19.4 (9.1) BC; G4-24,0 (9,0) B; G5-8.1 (3.2) D; G6 -18,0 (6,2) C; G7-7.8 (2,6) D; G8-6.3 (2,5) D. Grupos 2, 3, 4 e 6 não tiveram falhas prematuras dos palitos contra os grupos 1, 5, 7 e 8, que apresentaram 2,2; 44,4; 75,6 e 33,3% de perdas prematuras, respectivamente. O teste de correlação foi realizado apresentando significância estatística, com valor de -0,736 (p-valor = 0,000), mostrando que, a medida que o percentual de perda prematura aumenta, a média da MPa diminui. Quanto ao modo de fratura, observou-se 44,97% de falhas do tipo mista, 51,70% de falhas do tipo adesiva, 3,33% de falhas do tipo coesiva do cimento. Quando é realizada a supressão do condicionamento com HF como pré-tratamento da superfície cerâmica IPS e.max Press, a aplicação de silano SPH, associada ao seu tratamento térmico, deve ser o método de silanização recomendado, embora os valores mais elevados de resistência de união tenham sido os obtidos quando utilizado o condicionamento com HF por 20s. Quando é realizada a redução do tempo de condicionamento com HF para 10s, a aplicação do silano (SPH ou SNH) deve ser sempre associada ao seu tratamento térmico. O SNH só deve ser usado se as superfícies das cerâmicas IPS e.max Press forem tratadas com HF. / This study devaluated the effect of different types of silanization and hydrofluoric acid on the microtensile bond strength of a lithium dissilicate ceramic system. Forty IPS e.max Press /Ivoclar Vivadent blocks (5x5x6mm) were cemented to Z250/3M ESPE resin blocks (5x5x6mm) using RelyX ARC/3M ESPE resin-cement according to the following silanization methods: G1: 20s hydrofluoric acid (HF) + non-hydrolyzed silane Primer-Activactor/Dentsply (NHS) dried at room temperature; G2: 20sHF + pre-hydrolyzed silane RelyX Ceramic-Primer/3M ESPE (PHS) dried at room temperature; G3: 10sHF + NHS dried with hot air (50oC-2min); G4: 10sHF + PHS + hot air; G5: NHS + hot air; G6: PHS + hot air; G7: NHS dried at room temperature; G8: PHS dried at room temperature. Before each silanization method, all ceramic blocks were abraded with SiC grit papers (220-600) and cleaned with 37% phosphoric acid (1min). The cementation was made with vertical load of 01 kg for 10 min. After cementation procedure, all ceramic/ciment/resin blocks were stored in distilled water (37oC) for 24h before being cut to obtain stick-shapped specimens (n=45) of approximately 1mm2 cross-sectional area for microtensile test (v=0.5mm/min). Statistical analysis was performed using ANOVA/Dunnett (p-value = 0,000). The mean MPa(SD) values were: G1-21.5(8.9)BC; G2-30.5(7.2)A; G3-19.4(9.1)BC; G4-24.0(9.0)B; G5-8.1(3.2)D; G6-18.0(6.2)C; G7-7.8(2.6)D; G8-6.3(2.5)D. Groups 2, 3, 4 and 6 had no sticks premature fail against groups 1, 5, 7 and 8, that had 2.2, 44.4, 75.6 and 33.3% of sticks premature fails, respectively. As the correlation coefficient was statistically significant, -0.736 (p-value = 0.000), it could be argued that as the percentage of premature loss increased the MPa mean decreases. The failure mode was 44.97% of mixed failures, 51.70% of adhesive failures, 3.33% of cohesive failures of the cement. When the pretreatment is performed without HF conditioning of the IPS e.max Press ceramic surface, then PHS with hot air application should be the silanization method recommended, although higher bond strength values were obtained when HF conditioning for 20s was used with this type of silane. When the time of HF conditioning is reduced for 10 sec, the application of silane (SPH or SNH) must be always related to its heat treatment. NHS should only be used if IPS e.max Press ceramic surfaces are treated with HF.
26

Efeito do fator cavitário na resistência adesiva à dentina de um sistema restaurador à base de silorano / C factor effect on bond strength of a restorative system based on silorane

Rebecca Cruz 07 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar o efeito do fator C na resistência adesiva à dentina humana de um compósito à base de silorano, comparando-o com um compósito à base de metacrilato. Foram utilizados 40 molares humanos hígidos. Em metade da amostra foi realizado um preparo do tipo Classe I, com dimensões de 4x4 mm e 2 mm de profundidade, enquanto na outra metade foi realizado um preparo virtual (flat) com auxílio de uma matriz de teflon branco, com as mesmas dimensões da cavidade (4x4x2 mm), apoiada na superfície de dentina exposta. Cada grupo foi divido em dois, de acordo com o sistema restaurador: Sistema Adesivo P90 e resina Filtek P90; Adper Scotchbond Multiuso e resina Filtek Z350 XT (3M ESPE). Após a aplicação do sistema adesivo segundo as especificações do fabricante, as cavidades (real e virtual) foram preenchidas com as resinas (Z350 XT e P90) em dois incrementos. Foi realizada a fotoativação de cada incremento durante 25s. Após uma semana, as coroas foram seccionadas, obtendo-se espécimes constituídos de resina/dente na forma de um paralelepípedo (palitos). Estes palitos foram utilizados para o teste de microtração (Emic), onde a resistência adesiva na unidade MPa foi calculada. Os resultados foram avaliados estatisticamente pelo teste de análise de variância ANOVA One-Way (p = 0,05), e pelo teste de múltiplas comparações Student Newman Keuls. Foi observada uma diferença estatística entre a resina P90 (flat= 16,137,7 MPa e Cavidade= 16,759,0 MPa) e a Z350 XT (flat= 25,8211,6 MPa e Cavidade=24,4713,5 MPa), independentemente do tipo de cavidade restaurada. E não foi possível observar diferença estatística entre os tipos de cavidades (real ou virtual) restauradas com a mesma resina. Através dos testes realizados, foi possível concluir que: o fator C não afetou a resistência adesiva dos dois sistemas restauradores utilizados, e o tipo de sistema restaurador afeta a resistência adesiva, sendo que o sistema à base de silorano apresenta resultados inferiores ao de metacrilato. / The purpose of this study is to evaluate the effect of the C factor in the bond strength of a composite based on silorane to human dentin, comparing its results with a methacrylate-based composite. A total of 40 human molars were used. In half of this sample was used a Class I standard preparation method, comprising the dimensions of 4x4 mm and 2 mm deep, while with the other half was used a virtual preparation method (flat), being applied a white Teflon matrix, respecting the same dimensions cavity (4x4x2 mm), supported on the surface of exposed dentin. Each group was divided into two parts, in accordance with the 2 different restorative systems: P90 Adhesive System and Filtek P90; Filtek Z350 XT and Adper Scotchbond Multipurpose (3 ESPE). Based on manufacturer's specifications the adhesive system was applied , the cavities (real and virtual) were filled with the resins (Z350 XT and P90) in two increments. Polymerization was performed for each increment during 25 seconds. After one week, the crowns were sectioned, obtaining specimens made of resin / tooth in the form of a parallelepiped (stick-shaped). These sticks were used in a microtensile test (Emic), where the bond strength was calculated in Mpa unit . It was used the analysis of variance One-Way ANOVA (p = 0.05) and also, the Student Newman Keuls test for multiple comparisons to evaluate the results statistically. It was observed a statistical difference between the P90 resin (flat = 16.137.7 MPa and cavity = 16.759.0 MPa) and Z350 XT (flat = 25.8211.6 MPa and cavity = 24.4713.5 MPa), regardless of the cavity restored. And it was not possible to observe a statistical difference between the types of cavities (real or flat) restored with the same composite. The conclusion of the tests is: the C factor did not affect the bond strength of two restorative systems applied, and the type of restorative system affects the bond strength, and the system based on silorano presents inferior results than to methacrylate system.
27

Avaliação comparativa pelos testes micropush-out e micro-cisalhamento da resistência adesiva de restaurações diretas de resina composta usando diferentes sistemas adesivos

Pereira, Cristina Alves 19 December 2008 (has links)
The bond strength may be influenced by the different composition and manipulation of the adhesive systems, the dentin structure and the method of evaluation. After exposure of the occlusal dentin surface 160 third human molars were divided in 2 groups (n=80) for the micropush-out (&#956;PBS) and microshear (&#956;SBS) bond strength tests. For the &#956;PBS, 4 groups (n=20) were obtained and a tapered cavity (2,5x1,5x1,0mm) was prepared on the dentin surface and restored with composite resin after treatment using different adhesive systems: Adper Single Bond, Adper Scotchbond MP, Prompt-L-Pop, AdheSE. After water storage for 24 hours, from 10 teeth per group, 1 oclusal slice (1,5 ±0,3mm) was obtained from each tooth, and the restoration submitted to vertical load. The other 10 teeth were storage for 12 months and then submitted to the same procedure. For the &#956;SBS another 80 teeth were divided into 4 groups (n=20), the dentin surface was treated using the same adhesive systems and composite resin cylinders (1x1mm) were constructed and polymerized in a single increment onto the bonding area. Ten specimens were tested after 24 hours and 10 after 12 months of water storage. The null hypotheses were that (1) the composition and manipulation of the adhesive systems, (2) the water storage and (3) the method of evaluation might influence the bond strength of direct composite resin restorations. Results of ANOVA did not show significant difference for the storage time factor (p=.6343), but there was difference between the methods (p<.0001), with higher values for the &#956;PBS test, and among the adhesive systems (p<.0001). The Adper Scotchbond and AdheSE systems presented higher bond strength values. Adhesive x method (p=.0002) and adhesive x method x time (p=.0037) interactions were significant, with different behaviors from adhesive systems within the method and time of evaluation. Conclusions were that the storage time might be not sufficient to result in alterations and that adhesive systems composition and manipulation might influence the bond strength. The &#956;PBS test, presented the higher bond values with lower coefficient of variation, indicating more consistence than the &#956;SBS test, besides of reproduce more faithfully clinical conditions. / Dentre os vários fatores que podem influenciar a resistência adesiva de diferentes sistemas adesivos à dentina estão as suas diferentes composições e manipulação, o substrato dentinário e a produção do teste. Após exposição da superfície dentinária oclusal 160 molares humanos foram divididos em 2 grupos (n=80) para os testes de micropush-out e micro-cisalhamento. Para o teste de micropush-out a superfície dentinária de 4 grupos (n=20) recebeu uma cavidade tronco-cônica (2,0x1,5x1,0mm) restaurada com resina composta após aplicação do sistema adesivo: Adper Single Bond (SLB); Adper Scotchbond MP (SMP); Prompt-L-Pop (PLP); Adhe SE (ADH). Após armazenagem em água por 24 horas, a partir de 10 dentes de cada grupo, foi obtida uma fatia oclusal (1,5 ±0,3mm) por dente cuja restauração foi submetida à carga vertical. Os outros 10 dentes de cada grupo foram armazenados por um ano e submetidos ao mesmo procedimento. Para o teste do micro-cisalhamento outros 80 dentes foram divididos em 4 grupos (n=20), a superfície dentinária foi tratada com os mesmos sistemas adesivos, e, diretamente sobre ela, cilindros de resina (1x1 mm) foram construídos e polimerizados em incremento único. Dez amostras de cada grupo foram testadas após 24 horas e as outras após um ano de armazenagem. As hipóteses nulas foram que (1) a composição e manipulação dos sistemas adesivos, (2) a armazenagem em água, e (3) o método de avaliação, não influenciam a resistência de união das restaurações de resina composta direta. A ANOVA não mostrou diferença significante para o fator tempo de armazenagem (p=0,6343), mas houve diferença entre os métodos de avaliação (p<0,0001), com valores mais altos para o micropush-out, e entre os adesivos (p<0,0001). O Adper Scotchbond MP e AdheSE apresentaram resultados melhores que os outros sistemas testados. As interações adesivos x métodos (p=0,0002) e adesivos x métodos x tempo (p=0,0037) foram significativas com comportamentos diferentes dos adesivos dentro do método e do tempo de armazenagem. Os resultados indicaram que a composição e manipulação dos adesivos influenciaram a resistência de união. O método micropush-out, além de resultar em valores mais altos de união, apresentou também menor coeficiente de variação, indicando ser mais consistente que o microcisalhamento, além de simular mais fielmente as condições clínicas. O tempo de armazenagem avaliado pode não ter sido suficiente para promover alteração que pudesse ser identificada no teste de resistência adesiva. / Mestre em Odontologia
28

Efeito do fator cavitário na resistência adesiva à dentina de um sistema restaurador à base de silorano / C factor effect on bond strength of a restorative system based on silorane

Rebecca Cruz 07 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar o efeito do fator C na resistência adesiva à dentina humana de um compósito à base de silorano, comparando-o com um compósito à base de metacrilato. Foram utilizados 40 molares humanos hígidos. Em metade da amostra foi realizado um preparo do tipo Classe I, com dimensões de 4x4 mm e 2 mm de profundidade, enquanto na outra metade foi realizado um preparo virtual (flat) com auxílio de uma matriz de teflon branco, com as mesmas dimensões da cavidade (4x4x2 mm), apoiada na superfície de dentina exposta. Cada grupo foi divido em dois, de acordo com o sistema restaurador: Sistema Adesivo P90 e resina Filtek P90; Adper Scotchbond Multiuso e resina Filtek Z350 XT (3M ESPE). Após a aplicação do sistema adesivo segundo as especificações do fabricante, as cavidades (real e virtual) foram preenchidas com as resinas (Z350 XT e P90) em dois incrementos. Foi realizada a fotoativação de cada incremento durante 25s. Após uma semana, as coroas foram seccionadas, obtendo-se espécimes constituídos de resina/dente na forma de um paralelepípedo (palitos). Estes palitos foram utilizados para o teste de microtração (Emic), onde a resistência adesiva na unidade MPa foi calculada. Os resultados foram avaliados estatisticamente pelo teste de análise de variância ANOVA One-Way (p = 0,05), e pelo teste de múltiplas comparações Student Newman Keuls. Foi observada uma diferença estatística entre a resina P90 (flat= 16,137,7 MPa e Cavidade= 16,759,0 MPa) e a Z350 XT (flat= 25,8211,6 MPa e Cavidade=24,4713,5 MPa), independentemente do tipo de cavidade restaurada. E não foi possível observar diferença estatística entre os tipos de cavidades (real ou virtual) restauradas com a mesma resina. Através dos testes realizados, foi possível concluir que: o fator C não afetou a resistência adesiva dos dois sistemas restauradores utilizados, e o tipo de sistema restaurador afeta a resistência adesiva, sendo que o sistema à base de silorano apresenta resultados inferiores ao de metacrilato. / The purpose of this study is to evaluate the effect of the C factor in the bond strength of a composite based on silorane to human dentin, comparing its results with a methacrylate-based composite. A total of 40 human molars were used. In half of this sample was used a Class I standard preparation method, comprising the dimensions of 4x4 mm and 2 mm deep, while with the other half was used a virtual preparation method (flat), being applied a white Teflon matrix, respecting the same dimensions cavity (4x4x2 mm), supported on the surface of exposed dentin. Each group was divided into two parts, in accordance with the 2 different restorative systems: P90 Adhesive System and Filtek P90; Filtek Z350 XT and Adper Scotchbond Multipurpose (3 ESPE). Based on manufacturer's specifications the adhesive system was applied , the cavities (real and virtual) were filled with the resins (Z350 XT and P90) in two increments. Polymerization was performed for each increment during 25 seconds. After one week, the crowns were sectioned, obtaining specimens made of resin / tooth in the form of a parallelepiped (stick-shaped). These sticks were used in a microtensile test (Emic), where the bond strength was calculated in Mpa unit . It was used the analysis of variance One-Way ANOVA (p = 0.05) and also, the Student Newman Keuls test for multiple comparisons to evaluate the results statistically. It was observed a statistical difference between the P90 resin (flat = 16.137.7 MPa and cavity = 16.759.0 MPa) and Z350 XT (flat = 25.8211.6 MPa and cavity = 24.4713.5 MPa), regardless of the cavity restored. And it was not possible to observe a statistical difference between the types of cavities (real or flat) restored with the same composite. The conclusion of the tests is: the C factor did not affect the bond strength of two restorative systems applied, and the type of restorative system affects the bond strength, and the system based on silorano presents inferior results than to methacrylate system.
29

Efeito da temperatura de secagem de dois tipos de silano e da supressão ou redução do tempo de condicionamento com ácido hidrofluorídrico na resistência de união entre uma cerâmica de dissilicato de lítio e um cimento resinoso / Effect of drying temperature of two silan types and elimination or reduction of conditioning hydrofluoridric acid time with the bond strenght between a lithium disilicate ceramic and a resin cement

Leticia Monteiro Peixoto 24 August 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este estudo avaliou o efeito de diferentes métodos de silanização e aplicação do ácido hidrofluorídrico (HF) sobre a resistência à microtração de uma cerâmica de dissilicato de lítio a um cimento resinoso. Quarenta blocos de IPS e.max Press /Ivoclar Vivadent (5x5x6mm) foram cimentados a blocos de resina Z250/3M ESPE (5x5x6mm) usando o cimento resinoso RelyX ARC/3M ESPE de acordo com os seguintes métodos de tratamento superficial: G1: 20s de ácido fluorídrico (HF) + silano não hidrolisado Primer-Activactor/Dentsply (SNH) seco à temperatura ambiente; G2: 20s HF + silano pré-hidrolisado RelyX Ceramic-Primer/3M ESPE (SPH) seco à temperatura ambiente; G3: 10s HF + SNH seco com ar quente (50oC-2min); G4: 10sHF + SPH seco com ar quente (50oC-2min); G5: sem ácido, SNH seco com ar quente (50oC-2min); G6: sem ácido, SPH seco com ar quente (50oC-2min); G7: sem ácido, SNH seco à temperatura ambiente; G8: sem ácido, SPH seco à temperatura ambiente. Antes de cada método de silanização, os blocos cerâmicos receberam acabamento com lixas de carbeto de silício (220-600) e limpeza com ácido fosfórico 37% (1min). A cimentação foi realizada com carga vertical de 1kg por 10min. Os conjuntos de cerâmica/cimento/resina foram armazenados em água destilada (37C) por 24 horas e depois seccionados em máquina de corte Isomet 1000 a fim de obter palitos (n = 40) de 1mm2 de área da seção transversal, que foram submetidos ao teste de microtração em máquina de ensaio universal Emic (v = 0,5mm/min). O modo de fratura foi avaliado em microscópio eletrônico de varredura. A análise estatística foi realizada utilizando ANOVA / Dunnett (p-valor = 0,000). As médias MPa e desvio padrão foram: G1-21,5 (8,9) BC; G2-30,5 (7,2) A; G3-19.4 (9.1) BC; G4-24,0 (9,0) B; G5-8.1 (3.2) D; G6 -18,0 (6,2) C; G7-7.8 (2,6) D; G8-6.3 (2,5) D. Grupos 2, 3, 4 e 6 não tiveram falhas prematuras dos palitos contra os grupos 1, 5, 7 e 8, que apresentaram 2,2; 44,4; 75,6 e 33,3% de perdas prematuras, respectivamente. O teste de correlação foi realizado apresentando significância estatística, com valor de -0,736 (p-valor = 0,000), mostrando que, a medida que o percentual de perda prematura aumenta, a média da MPa diminui. Quanto ao modo de fratura, observou-se 44,97% de falhas do tipo mista, 51,70% de falhas do tipo adesiva, 3,33% de falhas do tipo coesiva do cimento. Quando é realizada a supressão do condicionamento com HF como pré-tratamento da superfície cerâmica IPS e.max Press, a aplicação de silano SPH, associada ao seu tratamento térmico, deve ser o método de silanização recomendado, embora os valores mais elevados de resistência de união tenham sido os obtidos quando utilizado o condicionamento com HF por 20s. Quando é realizada a redução do tempo de condicionamento com HF para 10s, a aplicação do silano (SPH ou SNH) deve ser sempre associada ao seu tratamento térmico. O SNH só deve ser usado se as superfícies das cerâmicas IPS e.max Press forem tratadas com HF. / This study devaluated the effect of different types of silanization and hydrofluoric acid on the microtensile bond strength of a lithium dissilicate ceramic system. Forty IPS e.max Press /Ivoclar Vivadent blocks (5x5x6mm) were cemented to Z250/3M ESPE resin blocks (5x5x6mm) using RelyX ARC/3M ESPE resin-cement according to the following silanization methods: G1: 20s hydrofluoric acid (HF) + non-hydrolyzed silane Primer-Activactor/Dentsply (NHS) dried at room temperature; G2: 20sHF + pre-hydrolyzed silane RelyX Ceramic-Primer/3M ESPE (PHS) dried at room temperature; G3: 10sHF + NHS dried with hot air (50oC-2min); G4: 10sHF + PHS + hot air; G5: NHS + hot air; G6: PHS + hot air; G7: NHS dried at room temperature; G8: PHS dried at room temperature. Before each silanization method, all ceramic blocks were abraded with SiC grit papers (220-600) and cleaned with 37% phosphoric acid (1min). The cementation was made with vertical load of 01 kg for 10 min. After cementation procedure, all ceramic/ciment/resin blocks were stored in distilled water (37oC) for 24h before being cut to obtain stick-shapped specimens (n=45) of approximately 1mm2 cross-sectional area for microtensile test (v=0.5mm/min). Statistical analysis was performed using ANOVA/Dunnett (p-value = 0,000). The mean MPa(SD) values were: G1-21.5(8.9)BC; G2-30.5(7.2)A; G3-19.4(9.1)BC; G4-24.0(9.0)B; G5-8.1(3.2)D; G6-18.0(6.2)C; G7-7.8(2.6)D; G8-6.3(2.5)D. Groups 2, 3, 4 and 6 had no sticks premature fail against groups 1, 5, 7 and 8, that had 2.2, 44.4, 75.6 and 33.3% of sticks premature fails, respectively. As the correlation coefficient was statistically significant, -0.736 (p-value = 0.000), it could be argued that as the percentage of premature loss increased the MPa mean decreases. The failure mode was 44.97% of mixed failures, 51.70% of adhesive failures, 3.33% of cohesive failures of the cement. When the pretreatment is performed without HF conditioning of the IPS e.max Press ceramic surface, then PHS with hot air application should be the silanization method recommended, although higher bond strength values were obtained when HF conditioning for 20s was used with this type of silane. When the time of HF conditioning is reduced for 10 sec, the application of silane (SPH or SNH) must be always related to its heat treatment. NHS should only be used if IPS e.max Press ceramic surfaces are treated with HF.
30

Influência do condicionamento da dentina na resistência de união de cimento de ionômero de vidro / Er,Cr:YSGG Laser Dentin Conditioning Influence on Glass Ionomer Cement Bond Strength

Bruna Uglik Garbui 05 July 2012 (has links)
Objetivos: avaliar o efeito de 3 parâmetros de condicionamento da dentina utilizando o laser de Er,Cr;YSGG (2,78m) na resistência de união (RU) de cimento de ionômero de vidro convencional (CIV). Materiais e métodos: Foram utilizados neste estudo 68 terceiros molares humanos, divididos aleatoriamente em 4 grupos (n=17/ grupo): G1 (grupo controle): nenhum tipo de condicionamento; G2: condicionamento com laser de Er,Cr;YSGG 0,5W, 25mJ, 20Hz ou G3: 1,0W, 50mJ, 20Hz e G4: 1,5W, 75mJ, 20Hz. Dois dentes em cada um dos grupos foram observados em microscopia eletrônica de varredura (MEV) para identificar as características morfológicas dos diferentes condicionamentos de superfície realizados. Os outros 15 dentes/grupo, foram preparados para ensaio de RU, obtendo uma superfície plana de dentina onde foram construídos 3 (n=45/grupo) corpos de prova em forma de cilindro (1mm de diâmetro X 0,5mm de altura) utilizando o ionômero de vidro Ketac Molar Easymix- 3M ESPE. Após o armazenamento em água destilada por 24h a 37oC os espécimes foram ensaiados pelo teste de microcisalhamento. Os valores finais de resistência adesiva foram calculados e expressos em Mega Pascal (MPa). Os dados foram coletados e analisados por ANOVA (p<0,001). Resultados: Os espécimes do G2 apresentaram os maiores resultados de RU (10,50MPa ±0,84), seguido pelo G1 (4.77MPa ±0.59), G3 (3.32MPa ±0.39) e G4 (2,94MPa ±0,50) que não apresentaram diferença estatisticamente significante quanto comparados entre si. A análise em MEV do G1 mostrou camada de smear ao longo de toda a superfície de dentina, enquanto nos outros grupos observou-se túbulos dentinários abertos, característicos na irradiação com laser de Er,Cr:YSGG. Os pulsos do laser no G2 eram facilmente distinguidos, o que não acontecia nos grupos G3 e G4, sugerindo que parâmetros de energia maiores podem causar efeitos mais extensos à estrutura da dentina. Na análise do padrão de fratura, todos os grupos apresentaram maior porcentagem de fratura adesiva G1:73,3%, G2:48,9% G3:66,7% e G4:64,4%. O tipo de fratura mista foi proporcional ao aumento da RU (G1:24,4%, G2:46,7%, G3:20,0% e G4:17,8%). Conclusão: O condicionamento da dentina com o laser de Er,Cr:YSGG na potência de 0,5W aumentou significativamente a RU do CIV à dentina, enquanto os demais parâmetros testados reduziram a RU. / Objective: To evaluate the effect of 3 dentin conditioning parameters of Er,Cr:YSGG laser (2,78 m) on the bond strength (BS) of conventional glass ionomer cement (CGIC). Methods: A total of 68 third molars were divided into four groups and was subjected to one of the following pretreatments: G1- the control group, no pretreatment was realized; G2, G3 and G4 were pretreated with Er,Cr:YSGG laser irradiation at 0.5 W, 25 mJ, 9 J/cm2, and 20 Hz (G2); 1.0 W, 50 mJ, 18 J/cm2, and 20 Hz (G3); and at 1.5 W, 75 mJ, 27 J/cm2, and 20 Hz (G4). A scanning electron microscopy (SEM) evaluation (n=2) of pretreated dentine and a microshear bond strength test (n=15) were performed after 24h of water immersion. To build the specimens (each of which was 1 mm in diameter) for the microshear test, CGIC (Ketac Molar Easy Mix) was used. The data were analysed by one-way ANOVA (p<0.001). Results: The G2 specimens presented the highest BS results (10.50 MPa ± 0.84), and G1 had the next highest average BS values (4.77 MPa ± 0.59). G3 (3.32 MPa ± 0.39) and G4 (2.94 MPa ± 0.50) demonstrated the lowest BS values, although the BS difference between these groups was not statistically significant (p>0.001). The SEM analysis of G1 revealed that the smear layer covered the entire dentine surface, whereas in groups G2, G3, and G4, irregular dentine was detected that possessed the open dentinal tubules and protruded peritubular dentine that are the characteristic results of laser irradiation. Laser pulses could easily be distinguished in G2 but not in G3 and G4, suggesting that higher energy parameters can broadly disrupt dentine structure and thereby affect the bonding of dentine to GIC. Conclusion: Dentine pretreatment with an Er,Cr:YSGG laser at a power of 0.5 W increased the BS of conventional GIC.

Page generated in 0.5184 seconds