• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • Tagged with
  • 49
  • 49
  • 43
  • 42
  • 19
  • 14
  • 14
  • 14
  • 11
  • 11
  • 10
  • 10
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estabilidade da interface de união de sistemas adesivos convencionais aplicados à dentina saturada com alcoóis / Stability of interface created by simplified etch-and-rinse adhesives to alcohol-saturated acid-etched dentin

Barros, Lívia de Oliveira January 2011 (has links)
BARROS, Lívia de Oliveira. Estabilidade da interface de união de sistemas adesivos convencionais aplicados à dentina saturada com alcoóis. 2011. 50 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by denise santos (denise.santos@ufc.br) on 2015-10-21T15:16:50Z No. of bitstreams: 1 2011_dis_lobarros.pdf: 840593 bytes, checksum: bb384edc1f750fa69323f9aa3daf978b (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2015-10-21T15:25:42Z (GMT) No. of bitstreams: 1 2011_dis_lobarros.pdf: 840593 bytes, checksum: bb384edc1f750fa69323f9aa3daf978b (MD5) / Made available in DSpace on 2015-10-21T15:25:42Z (GMT). No. of bitstreams: 1 2011_dis_lobarros.pdf: 840593 bytes, checksum: bb384edc1f750fa69323f9aa3daf978b (MD5) Previous issue date: 2011 / There is a consensus that the resin-dentin bond instability is correlated with increased hydrophilic resin monomer content in dentin adhesive. Thus, more durable bonds could be created when more hydrophobic resins were used. One way to bond hydrophobic monomers to acid-etched dentin is saturating the demineralized dentin with ethanol instead of water (ethanol-wet bonding technique). The objective of this in vitro study was to evaluate the effect of “alcohol wet bonding” technique on the stability of adhesive interface produced by two-step etch-and-rinse adhesives systems. For this, it was used 20 human third molars that had superficial dentin exposed and were randomly divided into four experimental groups (n=5): Adper Single Bond 2 (SB) bonded to acid-etched dentin saturated with water or ethanol; and XP Bond (XP) bonded acid-etched dentin saturated with water or 99.5% tert-butanol. The simplified dentin dehydration protocol was performed using 2 μl 100% ethanol or 99.5% tert-butanol directly applied in dentin for 60 s. Composite build-ups were built on dentin surface and specimens were cut into non-trimming dentin-composite beams to microtensile testing. Beams from each tooth were divided equally in two subgroups: immediately tested and aged by immersion in 10% NaOCl solution for 1 h. Specimens were pulled until failure at crosshead speed of 1 mm/min and bond strength was calculated. Fractured sticks were analyzed and classified according to the failure mode as mixed, adhesive, cohesive in dentin and cohesive in composite; and expressed in percentage. Data from μTBS test were statistically analyzed using three-way ANOVA and Tukey tests (α=0.05). Additional dentin disks were bonded using the same groups tested and the morphological characteristics of adhesive interface were investigated by light microscopy after immersion in ammoniacal silver nitrate solution. μTBS results showed that NaOCl solution reduced significantly bond strength comparing with the control groups (p<0.05) and increased the silver nitrate interfacial deposit for all adhesives tested. SB used in ethanol saturated-dentin showed significant lower bond strength values in comparison with SB control group, and this same tendency was observed in the silver nitrate deposition. The use of tert-butanol did not influence XP bond strengths values and silver nitrate deposits. Conclusion: The “alcohol wet bonding” simplified technique used in the present study was not able to improve resin-dentin bond stability for simplified etch-and-rinse adhesive systems. / Existe um consenso de que a instabilidade da interface de união resina-dentina está relacionada com a quantidade de monômeros hidrofílicos presentes no sistema adesivo. Dessa forma, interfaces adesivas mais duradouras seriam alcançadas com a utilização de sistemas adesivos mais hidrofóbicos. Uma maneira de unir monômeros hidrófobos à dentina é através da saturação da matriz dentinária desmineralizada por etanol ao invés de água (ethanol-wet bonding technique). O objetivo deste trabalho in vitro foi avaliar o efeito do protocolo de saturação dentinária, utilizando alcoóis, na estabilidade da interface de união produzida por sistemas adesivos convencionais de dois passos. Para isso, foram utilizados 20 terceiros molares humanos, que tiveram a dentina coronária exposta e foram distribuídos aleatoriamente em quatro grupos experimentais (n=5): Adper Single Bond 2 (SB) aplicado sobre dentina saturada com água ou etanol; e XP Bond (XP) aplicado sobre dentina saturada com água ou tert-butanol. O protocolo de saturação da dentina foi realizado através da aplicação de 2 μl de etanol 100% ou tert-butanol 99,5% diretamente sobre a dentina por um período de 60 s. Um platô de resina composta foi confeccionado sobre superfície dentinária após a aplicação do sistema adesivo e os espécimes foram cortados pela técnica non-trimming de obtenção de palitos para o teste de microtração. Os palitos de cada dente foram igualmente divididos em dois subgrupos: imediatamente testado ou envelhecido em solução de NaOCl a 10% por 1 hora. Os espécimes foram tracionados até a ruptura da união a uma velocidade de 1 mm/min e sua força de união mensurada. Os palitos fraturados foram analisados e classificados de acordo com o modo de fratura em mista, adesiva, coesiva em dentina e coesiva em compósito, e os valores expressos em porcentagem. Os valores de resistência de união foram estatisticamente analisados usando os testes ANOVA a três critérios e Tukey (α=0.05). Discos extras de dentina foram submetidos aos procedimentos adesivos de cada grupo testado e utilizados para investigar as características morfológicas da interface de união através de microscopia óptica após imersão em solução amonical de nitrato de prata. Os resultados do teste de microtração mostraram que a imersão em solução de NaOCl reduziu significativamente a força de união em comparação aos grupos controle (p<0.05) e aumentou a nanoinfiltração das interfaces adesivas de todos os sistemas adesivos testados. A saturação da dentina com etanol 100% reduziu os valores de resistência adesiva para SB quando comparado ao grupo controle, e esta mesma tendência foi observada na infiltração de prata. O uso do tert-butanol 99,5% não afetou os valores de resistência adesiva para o XP, assim como a deposição de nitrato de prata na interface adesiva. Conclusão: Os protocolos simplificados de saturação da dentina com alcoóis utilizados no presente estudo não foram capazes de melhorar a estabilidade da interface de união para sistemas adesivos convencionais de dois passos.
2

Mapeamento da variação regional da resistência adesiva em superfícies planas de dentina.

Terada, Raquel Sano Suga 22 February 2001 (has links)
O presente trabalho avaliou a influência das variações morfológicas do substrato dentinário na resistência de união à microtração de três sistemas adesivos resinosos: Clearfil Liner Bond 2V, One-Step e Single Bond, empregando como substrato superfícies planas de dentina. Para o preparo e exposição da superfície de dentina, o esmalte oclusal foi desgastado com lixas de carbureto de silício de granulação 320 e 600. Doze dentes foram tratados com um dos sistemas adesivos e foi aplicada uma camada de 1 centímetro de altura em resina composta Z100, pela técnica incremental. Após armazenagem em água destilada em estufa a 37ºC por 24 horas, os espécimes foram preparados para serem submetidos ao teste de microtração. Utilizando-se uma máquina de cortes seriados, os dentes foram fatiados em espessuras de aproximadamente 0,8 mm nos sentidos mésiodistal e vestíbulo-lingual, obtendo-se médias de áreas de adesão de 0,7 mm2. Foram obtidos, em média, 23 espécimes por dente. Identificando-se cada espécime através de um código de cores, a superfície de cada dente foi mapeada. Para a leitura da resistência de união, cada espécime em forma de “palito" foi afixado individualmente em um dispositivo de microtração, Bencor Multi-T, de modo a posicionar a área de adesão perpendicularmente ao longo eixo do espécime. Após o teste, o modo de fratura da interface adesiva foi avaliado. Os resultados obtidos permitiram concluir que existe uma variação regional da resistência de união em superfícies planas de dentina. Independentemente do sistema adesivo empregado, a variação da resistência de união encontrada em superfícies planas de dentina foi determinada por variações no substrato dentinário.Comparando-se a resistência de união entre os materiais, os sistemas One-Step (53,97 ± 12,58 MPa) e Single Bond (52,59 ± 17,67 MPa) apresentaram uma resistência semelhante e estatisticamente superior ao sistema Clearfil Liner Bond 2V (32,90 ± 12,43 MPa). Comparando-se a resistência de união à dentina central e à dentina periférica, os três materiais não apresentaram uma diferença estatisticamente significante. / The present work evaluated the influence of morphological variations of the dentinal substrate in the microtensile adhesive strength of three adhesive systems: Clearfil Liner Bond 2V, One-Step and Single Bond, using flat dentin surfaces. For the preparation and exposure of the dentin surface, the occlusal enamel was ground with 320 and 600 – grit SiC paper. The teeth were treated with one of the adhesive systems and a 1cm thick layer of Z100 resin composite was built up on the surface. After storage in distilled water at 37ºC for 24 hours, the specimens were prepared to be subjected to the microtensile test. With the aid of a micrometer the teeth were serially sectioned in both “x" and “y" directions to result in several bonded sticks of approximately 0.7 mm2 of cross-sectional area. Approximately twenty-three specimens per tooth were obtained. Each specimen was identified by a color code and the flat dentin surface was mapped. For the reading of the adhesive strength, each bonded stick was individually gluded to a Bencor Multi-T microtensile device with the adhesive area perpendicularly oriented to the long axis of the device. After testing, the mode of fracture of the adhesive interface was evaluated. The conclusions of this study were: there is a regional variance in the adhesive strenght on a flat dentin surface; regardless of the adhesive system used, the variation of the adhesive strength found on flat dentin surfaces was determined by variations in the dentinal substrate; when comparing the adhesive strength among the materials, One-Step (53,97 MPa ± 12,58) and Single Bond (52,59 MPa ± 17,67) systems presented a adhesive strength similar and statistically higher than the Clearfi Liner Bond 2V (32,90 MPa ± 12,43) system; when comparing the adhesive strength to both central and peripheral dentin, the three materials did not present any statistically significant differences.
3

Mapeamento da variação regional da resistência adesiva em superfícies planas de dentina.

Raquel Sano Suga Terada 22 February 2001 (has links)
O presente trabalho avaliou a influência das variações morfológicas do substrato dentinário na resistência de união à microtração de três sistemas adesivos resinosos: Clearfil Liner Bond 2V, One-Step e Single Bond, empregando como substrato superfícies planas de dentina. Para o preparo e exposição da superfície de dentina, o esmalte oclusal foi desgastado com lixas de carbureto de silício de granulação 320 e 600. Doze dentes foram tratados com um dos sistemas adesivos e foi aplicada uma camada de 1 centímetro de altura em resina composta Z100, pela técnica incremental. Após armazenagem em água destilada em estufa a 37ºC por 24 horas, os espécimes foram preparados para serem submetidos ao teste de microtração. Utilizando-se uma máquina de cortes seriados, os dentes foram fatiados em espessuras de aproximadamente 0,8 mm nos sentidos mésiodistal e vestíbulo-lingual, obtendo-se médias de áreas de adesão de 0,7 mm2. Foram obtidos, em média, 23 espécimes por dente. Identificando-se cada espécime através de um código de cores, a superfície de cada dente foi mapeada. Para a leitura da resistência de união, cada espécime em forma de “palito” foi afixado individualmente em um dispositivo de microtração, Bencor Multi-T, de modo a posicionar a área de adesão perpendicularmente ao longo eixo do espécime. Após o teste, o modo de fratura da interface adesiva foi avaliado. Os resultados obtidos permitiram concluir que existe uma variação regional da resistência de união em superfícies planas de dentina. Independentemente do sistema adesivo empregado, a variação da resistência de união encontrada em superfícies planas de dentina foi determinada por variações no substrato dentinário.Comparando-se a resistência de união entre os materiais, os sistemas One-Step (53,97 ± 12,58 MPa) e Single Bond (52,59 ± 17,67 MPa) apresentaram uma resistência semelhante e estatisticamente superior ao sistema Clearfil Liner Bond 2V (32,90 ± 12,43 MPa). Comparando-se a resistência de união à dentina central e à dentina periférica, os três materiais não apresentaram uma diferença estatisticamente significante. / The present work evaluated the influence of morphological variations of the dentinal substrate in the microtensile adhesive strength of three adhesive systems: Clearfil Liner Bond 2V, One-Step and Single Bond, using flat dentin surfaces. For the preparation and exposure of the dentin surface, the occlusal enamel was ground with 320 and 600 – grit SiC paper. The teeth were treated with one of the adhesive systems and a 1cm thick layer of Z100 resin composite was built up on the surface. After storage in distilled water at 37ºC for 24 hours, the specimens were prepared to be subjected to the microtensile test. With the aid of a micrometer the teeth were serially sectioned in both “x” and “y” directions to result in several bonded sticks of approximately 0.7 mm2 of cross-sectional area. Approximately twenty-three specimens per tooth were obtained. Each specimen was identified by a color code and the flat dentin surface was mapped. For the reading of the adhesive strength, each bonded stick was individually gluded to a Bencor Multi-T microtensile device with the adhesive area perpendicularly oriented to the long axis of the device. After testing, the mode of fracture of the adhesive interface was evaluated. The conclusions of this study were: there is a regional variance in the adhesive strenght on a flat dentin surface; regardless of the adhesive system used, the variation of the adhesive strength found on flat dentin surfaces was determined by variations in the dentinal substrate; when comparing the adhesive strength among the materials, One-Step (53,97 MPa ± 12,58) and Single Bond (52,59 MPa ± 17,67) systems presented a adhesive strength similar and statistically higher than the Clearfi Liner Bond 2V (32,90 MPa ± 12,43) system; when comparing the adhesive strength to both central and peripheral dentin, the three materials did not present any statistically significant differences.
4

Influência de métodos de esterilização nas propriedades físicas do substrato dental / Influence of sterilization methods on physical properties of dental substrate

Nogueira, Juliane Cristina Ciccone 05 February 2010 (has links)
O objetivo do presente estudo foi avaliar a influência de métodos de esterilização do substrato dental sobre a microdureza de dentes extraídos (esmalte e dentina radicular) submetidos a ciclos de pH, e ainda verificar a influência destes métodos sobre a resistência adesiva do esmalte, dentina coronária e radicular. Para os testes de microdureza, dez terceiros molares extraídos foram seccionados em 40 fragmentos de esmalte e 40 de dentina radicular, sendo divididos aleatoriamente em 4 grupos (para ambos os substratos): Controle - não esterilizado, Óxido de Etileno 7h ciclo de OE/48h aeração, Autoclave 30 à 121oC e Formalina 10% - por 7 dias. Após a esterilização, as amostras foram lavadas, reumidificadas e submetidas a ciclos de pH. Os testes de microdureza em profundidade (30, 60, 90, 120 e 300&micro;m) foram realizados no substrato hígido e desmineralizado. Para os teste de resistência adesiva, 30 terceiros molares extraídos foram seccionados em 60 fragmentos de esmalte, 60 fragmentos de dentina coronária e 60 fragmentos de dentina radicular, sendo divididos aleatoriamente em 4 grupos (para todos os substratos): Controle, Óxido de Etileno, Autoclave e Formalina 10%. Em seguida, os sítios de adesão foram demarcados e cilindros de resina composta foram confeccionados em 3 incrementos. Após 24 horas, os espécimes foram submetidos a testes de cisalhamento. Os dados obtidos para ambas as avaliações foram submetidos à ANOVA e teste de Fisher (&alpha; =0,05). Para microdureza em esmalte hígido pode-se verificar que o controle apresentou maior valor de dureza e estatisticamente diferente dos outros grupos, sendo que os métodos promoveram alteração da dureza, diminuindo-a (controle>óxido de etileno>autoclave>formalina). Contudo, para as profundidades não houve diferença estatística. Para o esmalte desmineralizado, o grupo controle apresentou maiores valores de dureza diferente estatisticamente da formalina e óxido de etileno e semelhante a autoclave (controle &asymp; autoclave > Formalina &asymp; óxido de etileno). Para as profundidades, observou-se que 30&micro;m < 60&micro;m &asymp; 90&micro;m &asymp; 120&micro;m < 300&micro;m. Para dentina radicular hígida pode-se observar que grupo controle apresentou maior valor de dureza, semelhante ao óxido de etileno e a formalina e diferente da autoclave, sendo a formalina similar ao óxido de etileno e diferente da autoclave. Entretanto, para as profundidades testadas não houve diferença estatística neste substrato. Para a dentina desmineralizada pode-se observar que o método não apresentou diferença significante, contudo para as profundidades ocorreu diferença, 30&micro;m foi similar a 90&micro;m e diferente de 300&micro;m e 120&micro;m. 300&micro;m apresentou as maiores médias de microdureza. Com relação aos testes de resistência adesiva em esmalte os métodos foram semelhantes entre si, assim como em dentina coronária, contudo em dentina radicular a formalina proporcionou maiores valores de adesão. Pode-se concluir que os métodos de esterilização influenciaram na microdureza do esmalte hígido e desmineralizado, bem como, na dentina hígida não promovendo alteração na dentina desmineralizada. Entretanto, os métodos não influenciaram nos resultados dos testes de resistência adesiva em esmalte e dentina coronária, alterando apenas a adesão em dentina radicular. / The aim of this study was to evaluate the influence of sterilization methods (ethylene oxide, steam autoclave and 10% formalin) on microhardness of extracted human teeth (enamel and root dentin) submitted to pH cycling, and to determine the influence of these methods on shear bond strength (enamel, coronary and root dentin). For microhardness test, 40 root dentin and 40 enamel blocks were prepared from freshly-extracted third molars. Specimens were randomly assigned to 4 groups according to sterilization method: control group no sterilized, ethylene oxide (7h- EtO gas cycles and 48 degassing period), steam autoclave (30´ at 121oC) and 10% formalin (7 days). After sterilizing, specimens were rinsed, moisten and submitted to pH cycling. Microhardness test in different depths (30, 60, 90, 120 and 300&micro;m) was realized on sound and demineralized areas. For shear bond strength test, 60 enamel, coronary and root dentin fragments were randomly divided into 4 groups according to sterilization method: control group, ethylene oxide, steam autoclave and 10% formalin. The bonding site was delimited and a resin composite cylinder was built. After 24h, the specimens were tested to failure. Data were analyzed using ANOVA and Fishers test (&alpha;=0.05). Sound enamel microhardness showed the highest values for control group, followed by ethylene oxide and steam autoclave, while the 10% formalin provided the lowest values. For depths, ANOVA showed no statistical difference among them. For demineralized enamel, control group was similar to steam autoclave group and higher than formalin and ethylene oxide (control &asymp; steam autoclave > formalin &asymp; ethylene oxide). Comparing depths, it was observed that 30&micro;m < 60&micro;m &asymp; 90&micro;m &asymp; 120&micro;m < 300&micro;m. For sound root dentin, control group was similar to formalin and ethylene oxide and higher than steam autoclave, being formalin similar to ethylene oxide and different from steam autoclave. It was not verified statistical difference for depths in this substrate. For desmineralized root dentin, ANOVA showed no statistical difference among the methods. For depths, 30&micro;m was similar to 90&micro;m and different from 300 and 120&micro;m. 300&micro;m provided the highest values. For bond strength in root dentin, it was observed statistically significant difference among sterilization methods, presenting formalin the highest values. However, when enamel and dentin were evaluated, ANOVA showed no statistical difference among sterilization methods. It can be concluded that, the sterilization methods employed in this study affect the microhardness of sound and demineralized enamel and sound dentin. On the other hand, the sterilization methods did not affect the microhardness of demineralized root dentin. Shear bond strength was affected by the sterilization methods only in root dentin.
5

Influência de métodos de esterilização nas propriedades físicas do substrato dental / Influence of sterilization methods on physical properties of dental substrate

Juliane Cristina Ciccone Nogueira 05 February 2010 (has links)
O objetivo do presente estudo foi avaliar a influência de métodos de esterilização do substrato dental sobre a microdureza de dentes extraídos (esmalte e dentina radicular) submetidos a ciclos de pH, e ainda verificar a influência destes métodos sobre a resistência adesiva do esmalte, dentina coronária e radicular. Para os testes de microdureza, dez terceiros molares extraídos foram seccionados em 40 fragmentos de esmalte e 40 de dentina radicular, sendo divididos aleatoriamente em 4 grupos (para ambos os substratos): Controle - não esterilizado, Óxido de Etileno 7h ciclo de OE/48h aeração, Autoclave 30 à 121oC e Formalina 10% - por 7 dias. Após a esterilização, as amostras foram lavadas, reumidificadas e submetidas a ciclos de pH. Os testes de microdureza em profundidade (30, 60, 90, 120 e 300&micro;m) foram realizados no substrato hígido e desmineralizado. Para os teste de resistência adesiva, 30 terceiros molares extraídos foram seccionados em 60 fragmentos de esmalte, 60 fragmentos de dentina coronária e 60 fragmentos de dentina radicular, sendo divididos aleatoriamente em 4 grupos (para todos os substratos): Controle, Óxido de Etileno, Autoclave e Formalina 10%. Em seguida, os sítios de adesão foram demarcados e cilindros de resina composta foram confeccionados em 3 incrementos. Após 24 horas, os espécimes foram submetidos a testes de cisalhamento. Os dados obtidos para ambas as avaliações foram submetidos à ANOVA e teste de Fisher (&alpha; =0,05). Para microdureza em esmalte hígido pode-se verificar que o controle apresentou maior valor de dureza e estatisticamente diferente dos outros grupos, sendo que os métodos promoveram alteração da dureza, diminuindo-a (controle>óxido de etileno>autoclave>formalina). Contudo, para as profundidades não houve diferença estatística. Para o esmalte desmineralizado, o grupo controle apresentou maiores valores de dureza diferente estatisticamente da formalina e óxido de etileno e semelhante a autoclave (controle &asymp; autoclave > Formalina &asymp; óxido de etileno). Para as profundidades, observou-se que 30&micro;m < 60&micro;m &asymp; 90&micro;m &asymp; 120&micro;m < 300&micro;m. Para dentina radicular hígida pode-se observar que grupo controle apresentou maior valor de dureza, semelhante ao óxido de etileno e a formalina e diferente da autoclave, sendo a formalina similar ao óxido de etileno e diferente da autoclave. Entretanto, para as profundidades testadas não houve diferença estatística neste substrato. Para a dentina desmineralizada pode-se observar que o método não apresentou diferença significante, contudo para as profundidades ocorreu diferença, 30&micro;m foi similar a 90&micro;m e diferente de 300&micro;m e 120&micro;m. 300&micro;m apresentou as maiores médias de microdureza. Com relação aos testes de resistência adesiva em esmalte os métodos foram semelhantes entre si, assim como em dentina coronária, contudo em dentina radicular a formalina proporcionou maiores valores de adesão. Pode-se concluir que os métodos de esterilização influenciaram na microdureza do esmalte hígido e desmineralizado, bem como, na dentina hígida não promovendo alteração na dentina desmineralizada. Entretanto, os métodos não influenciaram nos resultados dos testes de resistência adesiva em esmalte e dentina coronária, alterando apenas a adesão em dentina radicular. / The aim of this study was to evaluate the influence of sterilization methods (ethylene oxide, steam autoclave and 10% formalin) on microhardness of extracted human teeth (enamel and root dentin) submitted to pH cycling, and to determine the influence of these methods on shear bond strength (enamel, coronary and root dentin). For microhardness test, 40 root dentin and 40 enamel blocks were prepared from freshly-extracted third molars. Specimens were randomly assigned to 4 groups according to sterilization method: control group no sterilized, ethylene oxide (7h- EtO gas cycles and 48 degassing period), steam autoclave (30´ at 121oC) and 10% formalin (7 days). After sterilizing, specimens were rinsed, moisten and submitted to pH cycling. Microhardness test in different depths (30, 60, 90, 120 and 300&micro;m) was realized on sound and demineralized areas. For shear bond strength test, 60 enamel, coronary and root dentin fragments were randomly divided into 4 groups according to sterilization method: control group, ethylene oxide, steam autoclave and 10% formalin. The bonding site was delimited and a resin composite cylinder was built. After 24h, the specimens were tested to failure. Data were analyzed using ANOVA and Fishers test (&alpha;=0.05). Sound enamel microhardness showed the highest values for control group, followed by ethylene oxide and steam autoclave, while the 10% formalin provided the lowest values. For depths, ANOVA showed no statistical difference among them. For demineralized enamel, control group was similar to steam autoclave group and higher than formalin and ethylene oxide (control &asymp; steam autoclave > formalin &asymp; ethylene oxide). Comparing depths, it was observed that 30&micro;m < 60&micro;m &asymp; 90&micro;m &asymp; 120&micro;m < 300&micro;m. For sound root dentin, control group was similar to formalin and ethylene oxide and higher than steam autoclave, being formalin similar to ethylene oxide and different from steam autoclave. It was not verified statistical difference for depths in this substrate. For desmineralized root dentin, ANOVA showed no statistical difference among the methods. For depths, 30&micro;m was similar to 90&micro;m and different from 300 and 120&micro;m. 300&micro;m provided the highest values. For bond strength in root dentin, it was observed statistically significant difference among sterilization methods, presenting formalin the highest values. However, when enamel and dentin were evaluated, ANOVA showed no statistical difference among sterilization methods. It can be concluded that, the sterilization methods employed in this study affect the microhardness of sound and demineralized enamel and sound dentin. On the other hand, the sterilization methods did not affect the microhardness of demineralized root dentin. Shear bond strength was affected by the sterilization methods only in root dentin.
6

Ação triboquímica do ciclo mastigatório na resistência ao cisalhamento de resinas compostas / Tribocorrosion effects of masticatory cycle on the composite resins shear bond strength

Contente, Marta Maria Martins Giamatei 07 October 2013 (has links)
Este trabalho avaliou in vitro a ação de estímulos triboquímicos que simulam o ciclo mastigatório na resistência ao cisalhamento de duas resinas compostas Filtek P90®- 3M ESPE (P) e Z250®-3M ESPE (Z) com e sem presença de contaminação salivar, assim como a liberação de íons e a qualidade e a quantidade do desgaste produzido. A amostra foi composta por 12 grupos experimentais (n=5): P1 e Z1, sem contaminação/contra dente decíduo; P2 e Z2, com contaminação/contra dente decíduo; P3 e Z3, sem contaminação/contra dente permanente; P4 e Z4, com contaminação/contra dente permanente; P5 e Z5 sem contaminação (controle); P6 e Z6 com contaminação (controle). Ensaios de tribocorrosão foram efetuados na configuração pino-placa de deslizamento linear alternativo, na presença da solução de saliva artificial, carga de 3N e frequência de 1Hz, totalizando 900 ciclos de desgaste durante 15 minutos. As pistas de desgaste foram caracterizadas por MEV, EDX e XRD e o volume de desgaste por análise da variação de massa. A MEV demonstrou que os grupos Z apresentaram maior quantidade de desgaste quando comparados aos grupos P e que os antagonistas de dente permanente apresentaram maior quantidade de resíduos do material desgastado que os antagonistas em dentes decíduos. A análise por XRD não apresentou variação na caracterização de nenhuma das amostras quando se comparou os espécimes antes e após a realização dos experimentos. Na análise por EDX observou-se picos correspondentes aos elementos Ítrio e Silício para os antagonistas dos grupos P e de Zircônia para os dos grupos Z. Os dados obtidos pelo ensaio de nanoendentação não apresentaram diferença estatisticamente significante para nenhum dos grupos estudados (ANOVA e Teste de Duncan p&le;0,05). Nenhuma diferença estatisticamente significante foi encontrada pelos corpos de prova em resina composta ou antagonistas em nenhum dos grupos estudados quando da análise da variação de massa. Os valores de resistência ao cisalhamento foram: P1 11,20 (±1,44); P2 9,28 (±1,88); P3 8,94 (±1,03); P4 5,76 (±1,47); P5 17,50 (±3,28); P6 15,31 (±1,19); Z1 12,17 (±1,56); Z2 9,60 (±1,56); Z3 10,79 (±3,33); Z4 9,14 (±2,06); Z5 9,77 (±2,27) e Z6 9,22 (±1,98). Os valores de resistência ao cisalhamento foram menores para os grupos P submetidos à contaminação salivar. Na análise de ICP-MS maior liberação de íons Cálcio foi constatada em todos os grupos. A liberação de íons Fosfato foi observada na solução resultante do ensaio tribológico do corpo de prova em resina composta P90 contra antagonista dente permanente. Conclui-se que não há alterações químicas na superfície das resinas após o ensaio mecânico de desgaste e a resina composta P90 apresentou os menores valores de resistência ao cisalhamento em comparação com a resina Z250. A contaminação salivar interferiu negativamente nos valores de resistência ao cisalhamento quando a resina composta P90 foi avaliada. Dente utilizado como contra corpo não teve sua superfície alterada pela incorporação de resíduos de desgaste da resina composta, mantendo o módulo de elasticidade e a nanodureza, sendo que o desgaste ocorreu de forma mais acentuada nas restaurações de resina composta Z250. A liberação de íons Cálcio foi maior que a de íons Fosfato em todas as situações analisadas e a liberação de íons Fosfato foi maior na situação em que o corpo de prova em resina composta P90 foi submetido ao ensaio tribológico contra antagonista dente permanente. O ciclo mastigatório interferiu na resistência ao cisalhamento da resina composta P90. / This study evaluated in vitro the action of tribochemical stimuli simulating the masticatory cycle on the shear bond strength of two composite resins Filtek P90®- 3M ESPE (P) and Z250®-3M ESPE (Z) - with and without salivary contamination, as well as the release of ions and the quality and amount of composite resin/tooth wear. Twelve experimental groups (n=5) were formed: P1 and Z1, without contamination/against primary tooth; P2 and Z2, with contamination/against primary tooth; P3 and Z3, without contamination/against permanent tooth; P4 and Z4, with contamination/against permanent tooth; P5 and Z5, without contamination (control); P6 and Z6, with contamination (control). Tribocorrosion assays were performed using the pin-on-plate configuration under linear reciprocating sliding, in the presence of an artificial saliva solution and under 3 N load and 1 Hz frequency, totalizing 900 wear cycles during 15 minutes. The wear was characterized by SEM, EDX and XRD analyses and the wear volume was determined by mass variation analysis. The SEM analysis showed that the Z groups presented less wear than the P groups, and that the permanent tooth antagonists presented more worn material residues than the primary tooth antagonists. The XRD analysis did not reveal variation in the characterization of any of the samples, comparing the specimens before and after the experiments. The EDX analysis revealed peaks corresponding to the elements yttrium and silicon for the P groups\' antagonists and zircon for the Z groups\' antagonists. Data from the nanoindentation test did not show statistically significant difference for any of the groups (ANOVA and Duncan test p&le;0.05). For the mass variation analysis, no statistically significant difference was found between the composite resin specimens or antagonists in any of the groups. The shear bond strength results were: P1 11.20 (±1.44); P2 9.28 (±1.88); P3 8.94 (±1.03); P4 5.76 (±1.47); P5 17.50 (±3,28); P6 15,31 (±1.19); Z1 12.17 (±1.56); Z2 9,60 (±1.56); Z3 10.79 (±3.33); Z4 9.14 (±2.06); Z5 9.77 (±2.27) and Z6 9.22 (±1.98). The shear bond strength values were lower in the P groups subjected to salivary contamination. The ICP-MS analysis revealed greater calcium ion release in all groups. Regarding phosphate ion, greater release was observed in the solution resulting from the tribological assay when the P90 composite resin specimens were tested against permanent tooth antagonists. In conclusion, there were no chemical alterations on resin surface after the mechanical wear assay and P90 composite resin presented lower shear bond strength values than Z250 composite resin. Salivary contamination affected negatively in the shear bond strength values when P90 resin composite was evaluated. Teeth used as counterbody did not have their surface altered by the incorporation of composite resin wear residues, maintaining the modulus of elasticity and nano-hardness, and the wear was more accentuated in the Z250 composite resin restorations. There was greater release of calcium ions compared with phosphate ions in all analyzed situations and the release of phosphate ions increased when P90 was subjected to tribological assay against a permanent tooth antagonist. Tribochemical stimuli simulating the masticatory cycle interfered with the shear strength of composite resin P90.
7

Influência da delimitação da área adesiva no ensaio mecânico de microcisalhamento / Evaluation of adhesive area delimitation on microshear test

Shimaoka, Angela Mayumi 26 June 2007 (has links)
Este estudo teve como objetivos avaliar se a delimitação da área adesiva a ser testada no ensaio mecânico de microcisalhamento é capaz de alterar os resultados de resistência de união obtidos; determinar se a delimitação da área adesiva do ensaio mecânico de microcisalhamento pode alterar o ranqueamento dos sistemas adesivos analisados e correlacionar os tipos de fratura encontrados com valores de resistência adesiva obtidos em cada um dos grupos experimentais. As unidades experimentais foram confeccionadas sobre 18 superfícies de dentina obtidas a partir de incisivos bovinos distribuídas aleatoriamente em 3 grupos, segundo o sistema adesivo a ser utilizado (Adper Single Bond 2, Clearfil Se Bond, Clearfil S3 Bond). Desta forma foram compostos 6 grupos experimentais segundo os dois fatores de variação a serem estudados: sistema adesivo e delimitação da área adesiva. Sobre cada superfície dentinária foram confeccionados 4 cilindros em resina composta, sendo 2 com delimitação da área adesiva e 2 sem a delimitação desta área, totalizando n=12. Após 24 horas de armazenamento os espécimes foram submetidos ao ensaio mecânico de microcisalhamento. O teste estatístico ANOVA (p<0,01) e o teste auxiliar de Tukey determinaram que todos os grupos experimentais em que a delimitação da área adesiva foi realizada apresentaram menores valores de resistência adesiva quando comparados aos seus respectivos grupos controle (sem delimitação da área adesiva). Para os grupos em que não foi realizada a delimitação da área não foram observadas diferenças estatisticamente significantes entre os adesivos empregados. Em contrapartida, quando não foi realizada a delimitação, o sistema adesivo Clearfil S3 Bond mostrou maiores valores de resistência adesiva quando comparado aos sistemas Adper Single Bond 2 e Clearfil SE Bond, que por sua vez não se mostraram estatisticamente diferentes entre si. Concluiu-se que a delimitação da área adesiva no ensaio de microcisalhamento alterou os resultados de resistência adesiva obtidos, e que a modificação da metodologia do ensaio mecânico de microcisalhamento foi capaz de alterar o ranqueamento dos sistemas adesivos analisados. / This study had as objectives to evaluate if the delimitation of adhesive area on microshear test is capable to modify the values of shear bond strength; to determine if this delimitation can modify the ranking of the analyzed adhesive systems and to correlate the found types of failure with the values of bond strength in each experimental group. The specimens were confectioned on 18 incisors bovine dentine surfaces randomly distributed into 3 groups, according to adhesive system used (Adper Single Bond 2, Clearfil If Bond, Clearfil S3 Bond). In such a way, 6 experimental groups were designed according to two factors of variation to be studied: adhesive system and delimitation of the adhesive area. Over each dentin surface were confectioned 4 composite resin cylinders, being 2 with delimitation of the adhesive area and 2 without the delimitation of this area, totalizing n=12. After 24 hours of storage the specimens were submitted to microshear test Statistical test ANOVA (p<0,01) and Tukey?s test determined that all the experimental groups where the delimitation of the adhesive area was carried through presented lesser values of shear bond strength when compared with its respective control groups (without delimitation of adhesive area). Groups without area delimitation did not been demonstrate statistical significant differences between adhesives. On the other hand, when such delimitation was not carried through, the adhesive system Clearfil S3 Bond demonstrates greater values of shear bond strength compared to Adper Single 2 Bond and Clearfil SE Bond, which did not showed statistical difference between them. It was concluded that the delimitation of the adhesive area in the microshear test altered the obtained results of adhesive resistance, and that the modification of microshear test methodology was capable to modify the ranking of the analyzed adhesive systems.
8

Resistência adesiva ao cisalhamento de reparos em porcelana condicionada com laser / Shear bond strenght of porcelain repairs etched with laser

Pedrazzi, Hamilton 26 November 2007 (has links)
O objetivo foi avaliar in vitro a resistência ao cisalhamento de reparos em porcelana condicionada com laser e compará-la aos tradicionais métodos de reparo condicionados com ácido hidrofluorídrico e ácido fosfórico. Neste estudo, foram utilizados dois condicionadores químicos de porcelana (ácido hidrofluorídrico a 10% - Dentsply; ácido fosfórico a 37% - 3M ESPE), um agente silano (Rely X Silano - 3M ESPE), um sistema adesivo (Scotchbond Multi-uso - 3M ESPE), um compósito restaurador (Filtek Z250 - 3M ESPE), uma porcelana odontológica (Ceramco 3 - Dentsply) e um laser de alta potência em regime de femtosegundo (Ti:Safira - Libra- S, Coherent). Sessenta pastilhas em porcelana foram confeccionadas e incluídas e anéis de PVC com resina acrílica quimicamente ativada. As pastilhas de porcelana foram polidas com lixas abrasivas em ordem decrescente de abrasividade para o aplainamento da superfície. Foram formados 6 Grupos (n=10) assim divididos: G1 - condicionamento com laser com potência 760mW; G2 - condicionamento com laser com potência de 760mW e aplicação de ácido fosfórico a 37% por 15s; G3: condicionamento com laser com potência de 900mW; G4 - condicionamento com laser com potência de 900mW e aplicação de ácido fosfórico a 37% por 15s; G5 - aplicação de ácido fosfórico 37% por 15s (grupo controle) e G6 - aplicação de ácido fluorídrico a 10% por dois minutos. Após o condicionamento da porcelana, foi aplicado agente silano para todos os corpos de prova, seguido da aplicação do sistema adesivo e polimerização por 20s. Foram confeccionados corpos de prova de resina composta na superfície da porcelana com a inserção de camadas através de matriz bipartida e de maneira incremental (2 incrementos), com fotopolimerização de 20 segundos por incremento, utilizando aparelho fotopolimerizador (XL 3000, 3M Dental Products). Em seguida a matriz foi removida e os anéis de resina com os corpos-de-prova confeccionados removidos do porta matriz e submetidos à nova fotopolimerização por mais 20 segundos. Depois de confeccionados os corpos-deprova foram levados á máquina de termociclagem por 1000 ciclos de 30 segundos em cada banho com temperatura entre 5ºC e 55ºC. Após a termociclagem os corpos-de-prova foram submetidos ao ensaio de cisalhamento. Os resultados foram avaliados estatisticamente por análise de variância (ANOVA 1 fator de variação) e teste de Tuckey (alfa=0,05). As médias e desvio padrão foram: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (letras iguais demonstram não haver diferença entre grupos). / The aim of this study was to evaluate in vitro the shear bond strength of repairs in porcelain conditioned with laser and to compare it to the traditional repair methods conditioned with hydrofluoric acid and phosphoric acid. In this study, were used two conditioning porcelain (10% hydrofluoric acid - Dentsply; 37% phosphoric acid - 3M ESPE), a silane agent (Rely X Silano - 3M ESPE), an adhesive system (Scotchbond Multi-uso - 3M ESPE), a composite resin (Filtek Z250 - 3M ESPE), a porcelain (Ceramco 3 - Dentsply) and a laser of high potency in femtosecond (Ti:Safira Libra-S, Coherent). Sixty porcelain discs were made and embedded in PVC rings using a polymethyl methacrylate resin. All specimen were smoothed with abrasive sandpapers in decreasing order of abrasiveness for the leveling of the surface. Six Groups were formed (n=10) being divided: G1 - conditioning with laser with potency 760mW; G2 - conditioning with laser with potency of 760mW and application of 37% phosphoric acid for 15s; G3: conditioning with laser with potency of 900mW; G4 - conditioning with laser with potency of 900mW and application of 37% phosphoric acid for 15s; G5 - application of 37% phosphoric acid for 15s (group control) and G6 - application of 10% hydrofluoric acid for two minutes. After the conditioning of the porcelain, silane agent was applied for all of the specimens, following by the application of the adhesive system and photoactivation for 20s. Specimens of composed resin were made in the surface of the porcelain aided with a metal matrix and insert of incremental layers (2 increments) with photoactivation of 20 seconds for increment. The photoactivation was performed with a visible light unit (XL 3000, 3M Dental Products). Afterwards the metal matrix was removed and the specimens were submitted to the new photoactivation for more 20 seconds. The specimens were submitted a thermal cycling by 1000 cycles of 30 seconds in each bath with temperature between 5ºC and 55ºC. After the thermal cycling , specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance - ANOVA One Way and Tuckey test (alfa=0,05). The averages and standard deviation: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (same letters demonstrate there not to be difference among groups).
9

Resistência e elasticidade da madeira e de juntas coladas de Eucalyptus grandis W. Hill ex-Maiden e seus impactos na mecânica de vigas laminadas coladas / Strength and elasticity of wood and glued joints of Eucalyptus grandis W. Hill ex Maiden and their impacts on the mechanic of glued laminated beams

Serrano, Luisa Julieth Parra 21 June 2013 (has links)
A presente pesquisa teve como objetivo geral a otimização dos parâmetros de colagem para a fabricação de madeira laminada colada de Eucalyptus grandis, enfatizado na interação madeira-adesivo. Foi avaliada a influência da rugosidade, pressão de colagem, tipo de adesivo e tempo de armazenamento da madeira após a preparação das superfícies a serem coladas. Essas variáveis que afetam a qualidade da adesão foram analisadas a partir da resistência apresentada pelas uniões submetidas ao esforço de cisalhamento. Para complementar a compreensão da mecânica das juntas coladas, efetuou-se a caracterização qualitativa da linha de cola mediante análises microscópicas e imagens de raios-X. Estudaram-se as correlações existentes entre os pares possíveis das variáveis massa específica, resistência ao cisalhamento, rugosidade, profundidade de penetração e porcentagem de falha na madeira. A resistência do plano de cola em situação crítica de cisalhamento foi avaliada também em ensaios de flexão de vigas laminadas coladas. A eficiência adesiva, que é a relação entre a resistência da madeira maciça e a resistência da madeira laminada colada, não variou significativamente entre adesivo, pressão de colagem e acabamento de superfície. A eficiência adesiva das juntas coladas de madeira de Eucalyptus grandis com adesivos Cascophen e Jowapur foi satisfatória por ter estado sempre no intervalo de 90,9 a 127,8%. Observaram-se correlações muito fracas entre a espessura da linha de cola e as variáveis massa específica, resistência ao cisalhamento, eficiência adesiva e porcentagem de falha na madeira. As vigas solidarizadas com o adesivo Jowapur apresentaram um baixo módulo de elasticidade quando comparado ao da madeira maciça, sem apresentar diferenças significativa na resistência à flexão. Os processos de fabricação adotados garantiram uma qualidade ótima às juntas coladas, inferida pela observação das falhas que ocorreram tanto nos ensaios de cisalhamento quanto nos ensaios de flexão, nos quais as rupturas se deram ao longo da madeira maciça sem afetar o plano de cola. / The objective of the present study was to optimize the parameters of glue to manufacture laminated wood of E. grandis, emphasized the interaction wood-adhesive. The influence of the roughness, bonding pressure, adhesive type and time of storage of the timber after preparing the surfaces to be bonded were evaluated. These variables that affect the quality of adherence were analyzed from the resistance presented by the joints subjected to shear stress. To complement the understanding of the mechanics of bonded joints, we performed a qualitative characterization of the glue line by microscopy and X-ray imaging. Were studied correlations between possible pairs of variables: density, shear strength, roughness, depth of penetration, percentage of wood failure. The resistance of the bonding surface in critical shear was also measured using bending tests of glued laminated beams. The adhesive efficiency, which is the ratio between the resistance of the wood and the glued laminated wood resistance, did not vary significantly between adhesive, pressure bonding and surface finish. The adhesive efficiency of the bonded joints of Eucalyptus grandis with Cascophen and Jowapur was satisfactory falling always in the range from 90.9 to 127.8%. Very weak correlations were observed between the variables glue line thickness, density, shear strength, adhesive efficiency and percentage of wood failure. The beams glued with the adhesive Jowapur showed a low modulus of elasticity compared to solid wood, without showing significant differences in flexural strength. The manufacturing processes adopted ensured the optimal quality of bonded joints. This was inferred by observing the failures that occurred in both shear tests as in bending tests. Ruptures occurred within the wood without affecting the bonding surface.
10

Estudo da resistência adesiva de cimentos de ionômero de vidro à dentina: microtração x microcisalhamento / Bond stregth of glass-ionomer cements to dentin: microtensile x microshear

Bonifacio, Clarissa Calil 29 October 2008 (has links)
Este estudo objetivou avaliar quantitativamente e qualitativamente a resistência adesiva de três diferentes tipos de cimentos de ionômero de vidro (CIV) por meio dos ensaios mecânicos de microtração e microcisalhamento. Quarenta superfícies planas de dentina foram divididas aleatoriamente em dois grupos, segundo o ensaio mecânico: microtração (n=24) e microcisalhamento (n=16). Posteriormente, cada grupo foi novamente dividido em quatro subgrupos, segundo o material restaurador utilizado: CIV de alta viscosidade (Ketac Molar Aplicap - 3M/ESPE), CIV modificado por resina (Fuji II LC encapsulado - CG Corporation), nano-ionômero (Ketac N100 - 3M/ESPE) e resina composta (Z100 - 3M/ESPE). Para o teste de microtração os dentes foram seccionados perpendicularmente a interface de união obtendo-se espécimes com área de superfície aderida de aproximadamente 1mm2. Para o teste de microcisalhamento foram confeccionados três cilindros de material restaurador em cada superfície de dentina. Todos os grupos foram armazenados em água destilada por 24h. Os ensaios foram realizados em Mini Instron a velocidade de 1mm/min. Os valores obtidos, expressos em MPa, foram submetidos à Análise de Variância (p<0,05) e o método de comparações múltiplas LSD. Foi encontrada diferença estatisticamente significante entre testes e entre materiais, demonstrando que o comportamento dos valores de resistência adesiva dos quatro tipos de materiais estudados depende do tipo de ensaio mecânico utilizado. A análise qualitativa dos padrões de fratura em lupa estereoscópica revelou fraturas predominantemente adesivas e mistas quando da utilização do microcisalhamento para todos os materiais estudados, enquanto para a microtração, observou-se um grande número de fraturas coesivas em material para o Ketac Molar e para o Fuji II LC. Os valores de resistência adesiva do Ketac Molar e do Fuji II LC são semelhantes aos encontrados à resina Z100, quando o teste utilizado foi o microcisalhamento. Com o teste de microtração houve diferença entre os grupos, sendo que Ketac Molar se comportou de maneira semelhante a N100 que foram estatisticamente inferiores a Fuji II LC, que por sua vez também foi inferior a Z100. Com base nesses resultados conclui-se que o ensaio mecânico de microcisalhamento foi o que melhor avaliou a resistência adesiva dos materiais ionoméricos. / The present study aim to quantitatively and qualitatively evaluate the adhesive resistance of three types of Glass Ionomer Cements (GIC) through microtensile and microshear tests. Forty flat dentine surfaces were randomly divided between the two types of mechanical test: microtensile (n=24) and microshear (n=16). Furthermore, each group was divided into four subgroups, according the material used: High Viscosity GIC (Ketac Molar Aplicap - 3M/ESPE), Resin Modified GIC (Fuji II LC encapsulated - CG Corporation), nano-ionomer (Ketac N100 - 3M/ESPE) and composite resin (Z100 -3M/ESPE) resin. For the microtensile test, the teeth were sectioned perpendicularly to the adhesive interface so 1mm2 surface specimens could be obtained. For the microshare test three cylinder shaped restorative material were produced per each dentine surface. All groups were stored in distillated water for 24h. All tests were performed with a Mini Instron machine at a crosshead speed of 1mm/min. The results obtained, expressed in MPa, were submitted to variance - ANOVA (p<0,05) and least significant differences (LSD) analysis. Test and materials were statistically different, indicating that the values for adhesive resistance obtained per material depend on the test used. The qualitative analysis of the fractures, carried out by light microscope at 40x magnification, revealed that fracture produced by the microshear test were mainly adhesives or mixed. Microtensile fractures were mainly cohesive within the material for Ketac Molar and for Fuji II LC. According to the microshear test, the adhesive resistance figures found for Ketac Molar and for Fuji II LC were similar to the ones found in Z100 resin. Nevertheless, the microtensile test demonstrated that there was difference between the groups, as Ketac Molar behaved in line with N100, which were statistically inferior to Fuji II LC that was poorer than Z100. The conclusion, base on these results, was that the microshear was the mechanical test that better evaluated the adhesive resistance of the studied ionomer-based materials.

Page generated in 0.4827 seconds