• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 67
  • 30
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 104
  • 104
  • 65
  • 64
  • 24
  • 24
  • 24
  • 21
  • 16
  • 16
  • 16
  • 13
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Análise dos critérios para ajuste do suporte ventilatório da ventilação mecânica / Analysis of criteria for ventilatory support adjustment of mechanical ventilation

Renata Pletsch Assunção 22 November 2016 (has links)
Introdução: A assistência ventilatória adequada é imprescindível para o tratamento do paciente ventilado artificialmente. A busca por parâmetros para realizar o ajuste ótimo e que tenham aplicação fácil a beira leito como, por exemplo, métodos não-invasivos, são desejáveis. Objetivo: analisar a acurácia diagnóstica das variáveis do padrão respiratório, da P0.1 esofágica e traqueal, para o ajuste da assistência ventilatória em pressão de suporte. Métodos: Vinte e sete pacientes internados em unidade de terapia intensiva foram consecutivamente incluídos no estudo. Todos pacientes estavam no modo de pressão de suporte, que foi aumentada para 20 cmH2O e diminui em passos de 3 cmH2O, até 2 cmH2O ou antes se o paciente apresentasse sinais de desconforto respiratório. Os pacientes foram monitorizados com cateteres para medidas de pressão esofágica e gástrica, com uma peça proximal ao tubo para mensurar a pressão traqueal a partir da oclusão da via aérea e com um pneumotacógrafo para medidas de fluxo. Durante todos níveis de suporte, foram gravados os dados dos cateteres esofágicos, gástricos, da traquéia, dados hemodinâmicos e do padrão respiratório. O ajuste da assistência ventilatória foi classificado como adequado, insuficiente e excessivo de acordo com critérios pré-estabelecidos. Resultados: Foram analisados 210 períodos com diferentes pressões de suporte e em 49% destes períodos a assistência foi excessiva, enquanto em 3,8% a assistência foi insuficiente. No início do estudo, enquanto os pacientes ainda estavam com a assistência ventilatória ajustada pela equipe assistente, 48,2% apresentavam assistência ventilatória excessiva. Pela pequena incidência de períodos com assistência ventilatória insuficiente, não foi avaliado a acurácia das variáveis para diagnóstico de assistência insuficiente. Para diagnosticar assistência ventilatória excessiva, a variável do padrão respiratório que se mostrou mais acurada foi a frequência respiratória, com sensibilidade de 90% e especificidade de 88% quando a frequência respiratória foi menor que 17 incursões por minuto. Outras variáveis do padrão respiratório não mostraram elevada acurácia. Também para o diagnóstico de assistência excessiva, foi elevada a acurácia da P0.1 esofágica (sensibilidade de 81% e especificidade de 70% quando P0.1 <= 1,9) e da P0.1 traqueal (sensibilidade de 81% e especificidade de 70% quando P0.1 <= 2,1). Conclusão: A ocorrência de assistência ventilatória excessiva foi significativamente maior que a assistência ventilatória insuficiente. A frequência respiratória menor que 17 foi a variável do padrão respiratório com maior acurácia para diagnosticar assistência ventilatória excessiva. As P0.1 esofágica e traqueal também tiveram acurácia elevas, mas menores que a frequência respiratória . / Introdution: The adequate assistance is essential for the treatment of mechanically ventilated patient. The search of parameters to achieve the optimal adjustment and with easy application to bedside, for example, non-invasive methods. Objective: Analyze the diagnostic accuracy of the breathing pattern variables, esophageal and tracheal P0.1 for adjustment of mechanical ventilation in pressure support ventilation. Methods: Twenty-seven patients in intensive care unit were consecutively included in the study. All patients were in the pressure support mode, which was raised to 20 cmH2O and decreased in steps of 3 cmH2O up to 2 cmH2O or earlier if the patient had signs of respiratory distress. Patients were monitored with catheters for esophageal and gastric pressure measurements, with the T-piece was used close to the tube to measure tracheal pressure during an airway occlusion and a pneumotachograph for flow measurements. Data was recorded for all support levels to esophageal, gastric, and tracheal pressures, also hemodynamic data and ventilatory pattern. The adjustment of mechanical ventilation was classified as adequate assistance, overassistance and underassistance according to pre-established criteria. Results: Two hundred and ten periods were analyzed with different pressures of support and 49% of these periods were overassistance, while 3,8% these periods were underassistance. At baseline, while patients were still ventilatory assistance set by assistance staff, 48,2% had overassistance. Due to the low incidence of periods with underassistance, the variables accurancy has not been evaluated. The variable breathing pattern that was more accurate diagnosing overassistance was the respiratory rate (90% sensitivity and specificity of 88 % when the respiratory rate was less than 17 breaths per minute). Other variables of the breathing pattern did not show high accuracy although esophageal P0.1 (sensitivity 81 % and specificity of 70 % when P0.1 <= 1,9) and tracheal P0.1 (sensitivity 81 % and specificity of 70 % when P0.1 <= 2,1) were high accuracy diagnosing overassistance. Conclusion: The occurrence of overassistance was significantly higher than underassistance. The respiratory rate below 17 was the variable breathing pattern more accurate to predict overassistance. The esophageal and tracheal P0.1 also had high accuracy but lower than the respiratory rate
72

Impedância respiratória de entrada: comparação entre os métodos convencional e de wavetube. / Input respiratory impedance: comparison between conventional and wavetube methods.

Mori, Vitor 26 August 2015 (has links)
A impedância respiratória de entrada pode ser obtida pela Técnica das Oscilações Forçadas (FOT) através de dois métodos diferentes: convencional e de wavetube. Nessa dissertação, primeiramente realizamos uma revisão bibliográfica com enfoque nos assuntos de interesse para esse trabalho, como definições e modelagem de impedância, descrições e bases teóricas para a realização dos dois métodos e descrição dos equipamentos utilizados por cada um dos métodos. A partir de dados experimentais da impedância, em camundongos machos do tipo BALB/c normais, obtidos em dois equipamentos diferentes fez-se uma comparação utilizando como base o Modelo de Fase Constante, analisando possíveis divergências e buscando compreender os motivos de eventuais discrepâncias. Um dos equipamentos (flexiVent, SCIREQ, Canadá) emprega o método convencional enquanto o outro equipamento foi desenvolvido pelo grupo do professor Zoltán Hantos, da Universidade de Szeged, Hungria, e se utiliza do método de wavetube. Tal trabalho foi motivado pela ausência de referências bibliográficas que comparam os dois métodos. A análise dos resultados experimentais nos sugere que os parâmetros obtidos para o Modelo de Fase Constante nos dois equipamentos são diferentes e não comparáveis. / The input respiratory impedance can be obtained by two different methods of performing the Forced Oscillations Technique (FOT): conventional and wavetube method. In this dissertation, first we made a literature review focusing on issues of interest to this work, as definitions and models of impedance, description and theoretical basis for the realization of the two methods and description of the equipments used by each method. Using experimental data of impedance in BALB/c male mice, from two different equipments a comparison was made based on the Constant Phase Model, analyzing possible differences between them and trying to understand the reasons for any discrepancies. The first equipment (flexiVent, SCIREQ, Canada) uses the conventional method while the second one, developed by the research group of Professor Zoltán Hantos of the University of Szeged, Hungary, uses the wavetube method. This work was motivated by the lack of literature references comparing the model parameters obtained by both methods. The analysis of experimental results suggests that the equipments are different and not comparable.
73

Quantification of respiratory motion in PET/CT and its significance in radiation therapy

Chakraborty, Chandrani. January 2008 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 113-115.
74

Studies of Spinal Motor Control Networks in Genetically Modified Mouse Models

Gezelius, Henrik, January 2009 (has links)
Diss. (sammanfattning) Uppsala : Uppsala universitet, 2009.
75

Contribution à la modélisation 3D du thorax humain durant le mouvement respiratoire : analyse in vivo de la cinématique des articulations du thorax / Contribution to 3D modelling of the human thorax in breathing movement : in vivo analysis of thorax joint kinematics

Beyer, Benoit 29 November 2016 (has links)
La respiration est un phénomène vital qui implique une synergie entre diverses structures anatomiques qui constituent le thorax. La physiologie articulaire reste un parent pauvre de la physiologie et la littérature concernant la quantification de la cinématique 3D des articulations du thorax durant le mouvement respiratoire est rare. Ce travail se concentre sur le développement et l'application d'une méthodologie permettant de répondre à cet objectif. La méthode développée combine le traitement de données tomodensitométriques réalisées à trois volumes pulmonaires différents et des techniques d'infographies. Les amplitudes (ROMs) et axes de mouvements (axe hélicoïdaux moyen, AHMs) ont été obtenus au niveau des articulations costo-vertébrales de 12 sujets asymptomatiques. En résumé, les amplitudes diminuent graduellement dans les étages inférieurs ; le volume pulmonaire et l'étage costal influencent significativement les amplitudes costales ; l'orientation des AHMs ne diffère pas entre les étages costaux. En complément, la méthode a été appliquée pour un échantillon de 10 patients atteints de mucoviscidose. La condition pathologique influençait significativement les amplitudes de mouvements mais pas l'orientation des AHMs. Enfin, le déplacement sternal, les variations de l'angle sternal et la cinématique des articulations sternocostales a été analysée. Les déplacements angulaires des côtes par rapport au sternum diminuaient dans les étages inférieurs comme au niveau des articulations costo-vertébrales. L'orientation des AHMs des articulations sternocostales ne différait pas entre les étages. Une corrélation linéaire a été mise en évidence entre les déplacements verticaux du sternum et les amplitudes de mouvement costales au niveau costo-vertébral et sternocostal. Ce travail contribue de façon substantielle à la modélisation 3D du thorax humain durant le mouvement respiratoire d'un point de vue qualitatif et quantitatif / Breathing is a vital phenomenon that implies synergy of various anatomical structures that constitute the thorax. Joint physiology remains a relatively poorly-known component of the overall thorax physiology. Quantitative literature related to in vivo thorax kinematics during breathing is scarce. The present work focuses specifically on developing and applying a methodology to reach this goal. The developed method combined processing of CT data obtained at different lung volumes and infographic techniques. Detailed ranges of motion (ROMs) and axes of movement (mean helical axes, MHAs) were obtained at costovertebral joints in 12 asymptomatic subjects; rib ROMs gradually decrease with increasing rib number; lung volume and rib level have a significant influence on rib ROM; MHAs did not differ between rib levels. In addition, the method was applied on a sample of 10 patients with cystic fibrosis. The pathological condition significantly influenced CVJ ROMs while the orientation of the MHAs did not differ. Finally, the sternal displacement, sternal angle variations and sternocostal joints (SCJ at rib1 to 7) kinematics during breathing motion were analyzed. Rib ranges of motion relative to sternum decreased with increasing rib number similarly to CVJ. Orientation of the MHAs did not differ between SCJ levels. A significant linear correlation was demonstrated between sternum vertical displacement and rib ranges of motion at both CVJ and SCJ. The present work substantially contributes to 3D modelling of human thorax in breathing at a joint level both qualitatively and quantitatively
76

Evaluation du travail respiratoire dans l'insuffisance respiratoire aigue de l'enfant / Work of breathing assessment in critically ill children

Mortamet, Guillaume 22 January 2018 (has links)
Chez l’enfant, l’insuffisance respiratoire aiguë est responsable de la majeure partie des admissions en soins intensifs. La population pédiatrique étant marquée par une grande hétérogénéité en termes d’âge, de pathologie respiratoire et de maturation pulmonaire, une individualisation de la prise en charge thérapeutique est indispensable. Dans ce contexte, différents outils sont disponibles pour évaluer de manière plus objective le travail respiratoire du patient en insuffisance respiratoire aiguë. Objectifs - Le principal objectif de la thèse est d’évaluer l’intérêt diagnostique et thérapeutique de la mesure du travail respiratoire dans l’insuffisance respiratoire aiguë hypercapnique de l’enfant.Méthodes - Trois principaux outils d’évaluation du travail respiratoire ont été utilisés dans nos travaux : la mesure des pressions œsogastriques, la mesure de l’activité électrique du diaphragme et la mesure de la consommation en oxygène par la calorimétrie.Résultats - Nous avons pu mettre en évidence les intérêts de ces outils de mesure aux différents stades d’évolution de la maladie : (i) à la phase initiale pour indiquer l’initiation d’une ventilation non invasive et pour optimiser ces réglages ; (ii) à la phase d’évolution de la maladie pour évaluer l’interaction patient-ventilateur ; (iii) à la phase de sevrage ventilatoire pour détecter précocement une augmentation du travail respiratoire.Conclusion - Tout au long du processus évolutif de la maladie, la surveillance objective du travail respiratoire peut aider à comprendre les mécanismes de la maladie pulmonaire, optimiser les réglages de l’assistance respiratoire, et adapter les interventions thérapeutiques. / Acute respiratory failure is the leading cause of hospital admissions in the pediatric intensive care unit and is associated with significant morbidity and mortality. Since the pediatric population is characterized by a great heterogeneity in terms of age and respiratory pathology, individualization of therapeutic management is essential. Different minimally invasive methods have been described to assess the patient's work of breathing in acute respiratory failure.Objectives - The main objective of the project was to assess the diagnostic and therapeutic contribution of the measurement of the work of breathing in children with acute hypercapnic respiratory failure.Methods - We used in the present work three tools to assess the work of breathing: oesogastric pressures, electrical activity of the diaphragm monitoring and oxygen consumption measurements.Results - We highlighted how these different methods are valuable during the ICU stay: (i) in the early phase of the disease to initiate or withdraw noninvasive ventilation and to optimize its settings; (ii) in the recovery phase to evaluate the patient-ventilator interaction; (iii) during the weaning process to early detect an increase in work of breathing.Conclusion - Throughout the disease process, the work of breathing assessment can be useful to enhance our understanding of the pathophysiology of lung disease, to optimize mechanical ventilation settings and adapt therapeutic interventions.
77

Técnica de oscilações forçadas monofrequência na análise em tempo real das alterações mecânicas ao longo do ciclo respiratório de asmáticos com diferentes níveis de obstrução ao fluxo aéreo / Forced oscillation technique monofrequencia in real-time analysis of changes to mechanical cycle of respiratory asthmatics with diferent levels of arflow obstructions

Juliana Veiga Cavalcanti 15 April 2010 (has links)
A análise da mecânica respiratória em tempo real pela Técnica de OscilaçõesForçadas (FOT) Monofrequência é de interesse nos estudos clínicos e diagnósticos de doenças respiratórias. Entretanto, ainda é escassa a análise de asmáticos com esta técnica. O presente trabalho avalia a contribuição da FOT monofrequência na análise das alterações mecânicas ao longo do ciclo respiratório e da dinâmica da impedância do sistema respiratório (Zrs) de asmáticos. Na primeira fase do estudo, 14 voluntários sadios (GC) e 70 asmáticos foram incluídos. Destes, 13 asmáticos apresentaram espirometria normal (NE), e o restante apresentava obstrução leve (OL; n=26), moderada (OM; n=18) e acentuada (OA; n=13). Através da FOT foram analisadas a impedância total do sistema respiratório (Zt), a impedância inspiratória e expiratória (Zi e Ze), a impedância no início da inspiração e da expiração (Zii e Zie), a impedância pico-a-pico (diferença entre Zii e Zie) e a variação média da impedância (diferença entre Zi e Ze). Na segunda fase do estudo, a dinâmica do sistema respiratório foi analisada através da variabilidade da impedância, traduzida pelo desvio padrão da Zrs (sdZrs), pelo desvio-padrão do logaritmo da Zrs (sdlnZrs) e pela sua complexidade, analisada através da entropia aproximada da Zrs (EnApZ). Foram analisados 62 pacientes asmáticos da mesma amostra, divididos em NE (n=12), OL (n=20), OM (n=18) e OA (n=12). O GC foi composto por 12 voluntários. Testes de diferenças entre médias, correlações entre os parâmetros da FOT e da espirometria, além de curvas ROC, foram usados para avaliar o potencial da FOT monofrequência na detecção das alterações mecânicas em tempo real na asma. A impedância foi maior nos asmáticos em relação ao GC, sendo progressivamente maior entre os asmáticos de acordo com o grau de obstrução: Zt (p<0,0001), Zi (p<0,0001), Ze (p<0,0001), Zii (p<0,0001), Zie (p<0,0001), Zpp (p<0,0001) e &#916;Zrs (p<0,0001). A dinâmica do sistema respiratória sofreu diferenças significativas em asmáticos. Houve aumento significativo de sdZrs com o grau de obstrução brônquica (p<0,0001), enquanto a complexidade do sistema diminuiu (EnApZ; p<0,002). Correlações excelentes ocorreram entre VEF1/CVF e Zt (r=-0,76), Ze (r=-0,77) e Zie (r=-0,78), enquanto correlações razoáveis foram verificadas entre os parâmetros espirométricos com sdZrs e EnApZ. Os melhores parâmetros para uso diagnóstico na asma foram Zt, Zi, Ze, Zii e Zie com AUC adequada para identificar obstrução leve e de alta acurácia para identificar obstrução moderada e acentuada. O sdZrs foi adequado para identificar obstrução moderada e acentuada. Estes resultados estão em concordância com os fundamentos fisiopatológicos da asma. A FOTmonofrequência permite uma análise não invasiva e detalhada do sistema respiratório de asmáticos nas diferentes fases do ciclo respiratório. A impedância respiratória, principalmente na fase inspiratória, traduz as alterações mecânicas na asma. A dinâmica do sistema respiratório está alterada na asma, com maior variabilidade e menor complexidade do sinal de impedância respiratória, caracterizando um sistema com menor adaptabilidade a condições de maior demanda metabólica presentes na vida diária. Estes resultados confirmam o elevado potencial de uso clínico e científico desta metodologia na avaliação de pacientes com asma. / The analysis of respiratory mechanics in real time by Monofrequency FOT is of great interest in clinical and diagnosis studies of respiratory diseases. However, the use of this technique for the analysis of patients with asthma is still limited. The present study evaluates the contribution of the Monofrequency FOT in the analysis of changes in respiratory mechanics during the breathing cycle and the dynamics of the respiratory system of asthmatics. In the first phase of the study, 14 healthy volunteers (CG) and 70 asthmatics were included. Among them, 13 patients with asthma had normal spirometry (NE), and the others showed mild obstruction (n=26), moderate (n = 18) and severe (n=13). The parameters analyzed through FOT were the total impedance of the respiratory system (Zt), the inspiratory and expiratory impedance (Zi and Ze) and the impedance at the beginning of inspiration and expiration (Zii and Zie). The impedance peak-to-peak (Zii - Zie) and the mean of impedance (Zi - Ze) were also evaluated. In the second phase, the respiratory system dynamics was analyzed through the impedance variability, reflected by the standard deviation of Zrs (sdZrs), and the standard deviation of the Zrs logarithm (sdlnZrs), and an impedance complexity was analyzed through the approximated entropy of the Zrs (ApEnZ). 62 patients with asthma were analyzed, divided into NE (n=12), mild (n=20), moderate (n=18) and severe (n=12). The CG was composed by 12 volunteers. Tests of differences between means, correlations between the FOT parameters, spirometry, and ROC curves, were used to evaluate the potential of Monofrequency FOT in the detection of asthma mechanical changes in real-time. The respiratory impedance was higher in asthmatics than in CG, being progressively bigger among asthmatics according to obstruction degree: Zt (p<0.0001), Zi (p<0.0001), Ze (p<0.0001), Zii (p<0.0001), Zie (p<0.0001), Zpp (p<0.0001) and &#916;Zrs (p<0.0001). The dynamics of the respiratory system suffered significant differences in asthmatics. There was a significant increase in sdZrs with the bronchial obstruction degree in asthma (p<0.0001), while the complexity of the system decreased (ApEnZ, p<0.002). Excellent correlations occurred between FEV1/FVC and Zt (r=-0.76), Ze (r=-0.77) and Zie (r=-0.78), while reasonable correlations were found between spirometric parameters with sdZrs and ApEnZ. The best parameters to be used in asthma diagnosis were Zt, Zi, Ze, Zii Zie with adequate AUC to identify mild obstruction and high accuracy in identifying moderate and severe obstructions. The sdZrs was adequated to identify moderate and severe obstruction. These results are in close agreement with the pathophysiologic basis of asthma. The Monofrequency FOT allows a noninvasive analysis of the asthmatics respiratory system in the different phases. The respiratory impedance, especially during inspiration, reflects on the mechanical changes in asthma. The respiratory system dynamics is altered in asthma, with greater variability and less complexity of the respiratory impedance signal, characterizing a system with less adaptability to conditions of greater metabolic demand on the daily life. These results confirm the high potential of clinical and scientific use of this methodology to evaluate patients with asthma.
78

Avaliação comparativa da mecânica ventilatória de pacientes com lesão renal aguda submetidos a hemodiálise diária ou a diálise peritoneal contínua / Comparative Evaluation of mechanical ventilation of patients with acute kidney injury underwent daily hemodialysis or continuous peritoneal dialysis

Almeida, Cibele Tais Puato de [UNESP] 26 February 2016 (has links)
Submitted by CIBELE TAÍS PUATO DE ALMEIDA null (ctpdalmeida@alunos.fmb.unesp.br) on 2016-04-01T18:34:01Z No. of bitstreams: 1 Tese Cibele Tais Puato de Almeida.pdf: 839793 bytes, checksum: 01a41de5a6976ff81d2d379acd327e1f (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-04-05T18:47:49Z (GMT) No. of bitstreams: 1 almeida_ctp_dr_bot.pdf: 839793 bytes, checksum: 01a41de5a6976ff81d2d379acd327e1f (MD5) / Made available in DSpace on 2016-04-05T18:47:49Z (GMT). No. of bitstreams: 1 almeida_ctp_dr_bot.pdf: 839793 bytes, checksum: 01a41de5a6976ff81d2d379acd327e1f (MD5) Previous issue date: 2016-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A Diálise Peritoneal Contínua (DPC) e a Hemodiálise (HD) diária são opções para o tratamento de pacientes com Lesão Renal Aguda (LRA). A DPC pode causar alterações na função respiratória principalmente relacionadas ao aumento da Pressão Intra-Abdominal (PIA) e a HD pode levar a hipoxemia pelo contato do sangue com o circuito extracorpóreo e pela disfusão do CO2 no dialisato. No entanto, ambos os métodos podem melhorar a mecânica respiratória e a oxigenação pela retirada de líquidos e consequentemente redução do edema pulmonar. O objetivo principal deste estudo foi comparar os efeitos da DPC e da HD diária na mecânica ventilatória e oxigenação de pacientes com LRA sob Ventilação Mecânica Invasiva (VMI). Metodologia: Estudo tipo coorte prospectivo que avaliou 154 pacientes, sendo 37 em DPC e 94 em HD. Foram avaliados, por até 3 dias, os parâmetros de mecânica respiratória como Complacência Estática (Cest) e Resistência do Sistema Respiratório (Rsr) e também o Índice de Oxigenação (IO). Os pacientes foram avaliados nos momentos 1, 2 e 3 (pré-diálise) e 1, 2 e 3 (pós-diálise) em relação a Cest e Rsr e nos momentos 1, 2 e 3 em relação ao IO. Para comparação entre as características clínicas iniciais dos pacientes foram utilizados os testes t de student, qui-quadrado e exato de fisher. Para comparação das variáveis Cest, Rsr e IO no tempo foi utilizado o modelo Anova de medidas repetidas, seguido do teste de comparações múltiplas de Wald ou Tukey. Foi considerado um nível de significância de 5%. Resultados: Na comparação dos parâmetros clínicos iníciais entre os dois grupos, todas as características foram iguais, exceto a idade que foi maior entre aqueles em DPC (70,8±11,6 Vs 60±15,8 - p<0,0001). Nos dois grupos a Cest aumentou significativamente, sem difereça entre os grupos – Pré-Diálise (DPC: 40±17,4, 42,8±17,2,48±19; HD: 39,1±21,3, 39,5±18,9, 45,2±21) Pós-Diálise (DPC: 42,8±17,2, 48±19, 57,1±18,3; HD: 42±19, 45±18,5, 56±24,8). A Rsr permaneceu estável entre os pacientes em DPC (Pré-Diálise: 10,4±5,1, 13,3±7,7, 13,5±10,3; Pós-Diálise: 13,3±7,7, 13,5±10,3, 11,1±5,9) e diminuiu entre os pacientes em HD (Pré-Diálise: 10,4±5,1, 10,4±5,1, 10,4±5,1; Pós-Diálise: 10,5±6,8, 10±4,9, 8,9±4,2). Houve diferença estatística na Rsr entre os grupos, no pós-diálise 1 e 2 (p=0,03). O IO aumentou nos dois grupos (DPC: 260,7±119, 252,7±87,1, 287,3±88,4; HD: 228±85, 257±84, 312,1±111,5), sem diferença estatística entre eles. Conclusão: Os resultados obtidos no presente trabalho sugerem que pacientes com LRA, sob VMI, submetidos tanto a DPC quanto a HD Diária apresentam melhora da mecânica ventilatória e da oxigenação, sem diferença entre os grupos. / The Continuous Peritoneal Dialysis (CPD) and daily Hemodialysis (HD) are options for the treatment of Acute Kidney Injury (AKI) patients. The CPD can cause changes in respiratory function mainly related to increase Intra-Abdominal Pressure (IAP) and HD can lead to hypoxemia due to blood contact with the extracorporeal circuit and the diffusion of CO2 in the dialysate. However, both methods can improve respiratory mechanics and oxygenation due to the fluid removal and consequently reduced pulmonary edema. The aim of this study was to compare the effects of the CPD and daily HD on respiratory mechanics and oxygenation of AKI patients undergoing Invasive Mechanical Ventilation (IMV). Methodology: A prospective cohort study evaluated 154 patients, 37 on CPD and 94 on HD. The respiratory mechanics parameters such as Static Compliance (Cest) and Resistance of the Respiratory System (Rsr) and Oxygenation Index (OI) were assessed for three days. Patients were evaluated at moments 1, 2 and 3 (pre-dialysis) and 1, 2 and 3 (post-dialysis) in relation to Cest and Rsr and at times 1, 2 and 3 in relation to the IO. The student t test, chi-square and fisher exact were used to compare the baseline patients characteristics. ANOVA model for repeated measures was used to compare the variables Cest, Rsr and OI, followed by the multiple comparison Tukey or Wald Test. Significance level was 5%. Results: Comparing the initial clinical parameters between the two groups, all characteristics were similar except that the age that was higher among those on CPD (70.8 ± 11.6 vs 60 ± 15.8 - p <0.0001). In both groups, Cest increased significantly, with no difference between the two groups – Pre-Dialysis (CPD: 40 ± 17.4, 42.8 ± 17.2, 48 ± 19; HD: 39.1 ± 21.3, 39. 5 ± 18.9, 45.2 ± 21) Post-Dialysis (CPD: 42.8 ± 17.2, 48 ± 19, 57.1 ± 18.3; HD: 42 ± 19, 45 ± 18.5, 56 ± 24.8). The Rsr remained stable among patients on CPD (Pre-Dialysis: 10.4 ± 5.1, 13.3 ± 7.7, 13.5 ± 10.3, Post-Dialysis: 13.3 ± 7.7, 13.5 ± 10.3, 11.1 ± 5.9) and decreased among HD patients (Pre-Dialysis: 10.4 ± 5.1, 10.4 ± 5.1, 10.4 ± 5, 1, Post-Dialysis: 10.5 ± 6.8, 10 ± 4.9, 8.9 ± 4.2) There was significant statistically difference in Rsr between the two groups at the post-dialysis moments 1 and 2 (p = 0.03). OI increased in both groups (CPD: 260.7 ± 119, 252.7 ± 87.1, 287.3 ± 88.4; HD: 228 ± 85, 257 ± 84, 312.1 ± 111.5), although there was not significant statistically difference between them. Conclusion: This study showed that AKI patients undergoing IMV and daily HD or CPD had improvement in the mechanical ventilation and oxygenation, with no difference between the two groups.
79

Técnica de oscilações forçadas monofrequência na análise em tempo real das alterações mecânicas ao longo do ciclo respiratório de asmáticos com diferentes níveis de obstrução ao fluxo aéreo / Forced oscillation technique monofrequencia in real-time analysis of changes to mechanical cycle of respiratory asthmatics with diferent levels of arflow obstructions

Juliana Veiga Cavalcanti 15 April 2010 (has links)
A análise da mecânica respiratória em tempo real pela Técnica de OscilaçõesForçadas (FOT) Monofrequência é de interesse nos estudos clínicos e diagnósticos de doenças respiratórias. Entretanto, ainda é escassa a análise de asmáticos com esta técnica. O presente trabalho avalia a contribuição da FOT monofrequência na análise das alterações mecânicas ao longo do ciclo respiratório e da dinâmica da impedância do sistema respiratório (Zrs) de asmáticos. Na primeira fase do estudo, 14 voluntários sadios (GC) e 70 asmáticos foram incluídos. Destes, 13 asmáticos apresentaram espirometria normal (NE), e o restante apresentava obstrução leve (OL; n=26), moderada (OM; n=18) e acentuada (OA; n=13). Através da FOT foram analisadas a impedância total do sistema respiratório (Zt), a impedância inspiratória e expiratória (Zi e Ze), a impedância no início da inspiração e da expiração (Zii e Zie), a impedância pico-a-pico (diferença entre Zii e Zie) e a variação média da impedância (diferença entre Zi e Ze). Na segunda fase do estudo, a dinâmica do sistema respiratório foi analisada através da variabilidade da impedância, traduzida pelo desvio padrão da Zrs (sdZrs), pelo desvio-padrão do logaritmo da Zrs (sdlnZrs) e pela sua complexidade, analisada através da entropia aproximada da Zrs (EnApZ). Foram analisados 62 pacientes asmáticos da mesma amostra, divididos em NE (n=12), OL (n=20), OM (n=18) e OA (n=12). O GC foi composto por 12 voluntários. Testes de diferenças entre médias, correlações entre os parâmetros da FOT e da espirometria, além de curvas ROC, foram usados para avaliar o potencial da FOT monofrequência na detecção das alterações mecânicas em tempo real na asma. A impedância foi maior nos asmáticos em relação ao GC, sendo progressivamente maior entre os asmáticos de acordo com o grau de obstrução: Zt (p<0,0001), Zi (p<0,0001), Ze (p<0,0001), Zii (p<0,0001), Zie (p<0,0001), Zpp (p<0,0001) e &#916;Zrs (p<0,0001). A dinâmica do sistema respiratória sofreu diferenças significativas em asmáticos. Houve aumento significativo de sdZrs com o grau de obstrução brônquica (p<0,0001), enquanto a complexidade do sistema diminuiu (EnApZ; p<0,002). Correlações excelentes ocorreram entre VEF1/CVF e Zt (r=-0,76), Ze (r=-0,77) e Zie (r=-0,78), enquanto correlações razoáveis foram verificadas entre os parâmetros espirométricos com sdZrs e EnApZ. Os melhores parâmetros para uso diagnóstico na asma foram Zt, Zi, Ze, Zii e Zie com AUC adequada para identificar obstrução leve e de alta acurácia para identificar obstrução moderada e acentuada. O sdZrs foi adequado para identificar obstrução moderada e acentuada. Estes resultados estão em concordância com os fundamentos fisiopatológicos da asma. A FOTmonofrequência permite uma análise não invasiva e detalhada do sistema respiratório de asmáticos nas diferentes fases do ciclo respiratório. A impedância respiratória, principalmente na fase inspiratória, traduz as alterações mecânicas na asma. A dinâmica do sistema respiratório está alterada na asma, com maior variabilidade e menor complexidade do sinal de impedância respiratória, caracterizando um sistema com menor adaptabilidade a condições de maior demanda metabólica presentes na vida diária. Estes resultados confirmam o elevado potencial de uso clínico e científico desta metodologia na avaliação de pacientes com asma. / The analysis of respiratory mechanics in real time by Monofrequency FOT is of great interest in clinical and diagnosis studies of respiratory diseases. However, the use of this technique for the analysis of patients with asthma is still limited. The present study evaluates the contribution of the Monofrequency FOT in the analysis of changes in respiratory mechanics during the breathing cycle and the dynamics of the respiratory system of asthmatics. In the first phase of the study, 14 healthy volunteers (CG) and 70 asthmatics were included. Among them, 13 patients with asthma had normal spirometry (NE), and the others showed mild obstruction (n=26), moderate (n = 18) and severe (n=13). The parameters analyzed through FOT were the total impedance of the respiratory system (Zt), the inspiratory and expiratory impedance (Zi and Ze) and the impedance at the beginning of inspiration and expiration (Zii and Zie). The impedance peak-to-peak (Zii - Zie) and the mean of impedance (Zi - Ze) were also evaluated. In the second phase, the respiratory system dynamics was analyzed through the impedance variability, reflected by the standard deviation of Zrs (sdZrs), and the standard deviation of the Zrs logarithm (sdlnZrs), and an impedance complexity was analyzed through the approximated entropy of the Zrs (ApEnZ). 62 patients with asthma were analyzed, divided into NE (n=12), mild (n=20), moderate (n=18) and severe (n=12). The CG was composed by 12 volunteers. Tests of differences between means, correlations between the FOT parameters, spirometry, and ROC curves, were used to evaluate the potential of Monofrequency FOT in the detection of asthma mechanical changes in real-time. The respiratory impedance was higher in asthmatics than in CG, being progressively bigger among asthmatics according to obstruction degree: Zt (p<0.0001), Zi (p<0.0001), Ze (p<0.0001), Zii (p<0.0001), Zie (p<0.0001), Zpp (p<0.0001) and &#916;Zrs (p<0.0001). The dynamics of the respiratory system suffered significant differences in asthmatics. There was a significant increase in sdZrs with the bronchial obstruction degree in asthma (p<0.0001), while the complexity of the system decreased (ApEnZ, p<0.002). Excellent correlations occurred between FEV1/FVC and Zt (r=-0.76), Ze (r=-0.77) and Zie (r=-0.78), while reasonable correlations were found between spirometric parameters with sdZrs and ApEnZ. The best parameters to be used in asthma diagnosis were Zt, Zi, Ze, Zii Zie with adequate AUC to identify mild obstruction and high accuracy in identifying moderate and severe obstructions. The sdZrs was adequated to identify moderate and severe obstruction. These results are in close agreement with the pathophysiologic basis of asthma. The Monofrequency FOT allows a noninvasive analysis of the asthmatics respiratory system in the different phases. The respiratory impedance, especially during inspiration, reflects on the mechanical changes in asthma. The respiratory system dynamics is altered in asthma, with greater variability and less complexity of the respiratory impedance signal, characterizing a system with less adaptability to conditions of greater metabolic demand on the daily life. These results confirm the high potential of clinical and scientific use of this methodology to evaluate patients with asthma.
80

Análise da aplicação do modelo de fase constante na avaliação da mecânica respiratória em animais durante broncoconstrição. / Analysis of application of constant phase model in the evaluation of respiratory mechanics in animals during bronconconstrição.

Renato de Lima Vitorasso 20 June 2016 (has links)
A avaliação da mecânica respiratória é realizada comumente por meio de modelagem matemática. Um modelo amplamente utilizado é o de fase constante que se ajusta à impedância respiratória. Uma das variáveis exibidas por equipamentos de ventilação que aplicam o modelo citado é o Coeficiente de Determinação (COD), um medidor do ajuste do modelo. Há algumas situações em que o COD pode apresentar-se baixo, como: sedação superficial, respiração espontânea, perturbações externas e não linearidade. Entretanto, apesar de os valores de COD estarem disponíveis em ventiladores que utilizam os modelos de fase constante, a literatura é escassa em trabalhos que o citem. O objetivo deste trabalho foi analisar o comportamento do COD em uma curva dose resposta de camundongos BALB/c divididos em um grupo controle e um grupo com modelo animal de asma (OVA) e propor uma alternativa caso o modelo de fase constate não possa ser aplicado. Foram encontrados piores ajustes nas doses mais altas, principalmente no grupo OVA. Foi encontrada uma associação entre parâmetros excluídos nas 5 primeiras medidas e doses (p=0,0026) no grupo OVA. Foram excluídas 11 mensurações na última dose enquanto na primeira ou segunda doses apenas 2. O risco relativo para apresentar medidas excluídas entre a última e primeira ou segunda doses foi: 5,5 e IC: 1,30 - 23,26. A problemática de ter-se encontrado diferenças nestes momentos é que estas são as medidas relacionadas aos maiores valores de parâmetros de cada dose e tradicionalmente são os valores apresentados em estudos científicos. Os valores de pressão traqueal máxima média e mínima comportaram-se de maneira similar em termos de discriminação intergrupos, apresentando diferença (p<0,05) nas doses de 0,3 e 1 mg/kg, assim como o Rn . Em termos de substituição, é possível optar pelo uso de valores de pressão traqueal em detrimento aos parâmetros modelados em momentos em que o modelo de fase constante não deveria ser aplicado, a exemplo de valores baixos de COD em momentos de extrema broncoconstrição. A utilização dos valores de pressão traqueal é viável, por não serem obtidos por meio de uma modelagem matemática e sim por mensuração. Portanto, como os parâmetros Rn G e H são obtidos por meio de modelagem matemática e não por mensuração direta, o mau ajuste do modelo significa que os parâmetros modelados não podem ser aplicados na análise da situação em questão. Ademais, como alternativa é possível utilizar valores de pressão mensurados como variável de resposta, ainda que estes não discriminem vias aéreas e parênquima. / Assessment of respiratory mechanics is commonly performed through the application of mathematical models. A widely applied model is the constant phase model, which fits the respiratory impedance. One of the variables presented by ventilators that apply this model is the Coefficient of Determination (COD), it is used to assess the goodness of fit of the model. There are situation where the COD value is low, such as: superficial sedation, spontaneous breathing, external disturbances and nonlinearity. However, despite the COD value are available for ventilators that apply the constant phase model, the literature is still scarce in studies that mention this coefficient. The aim of this study was to analyze the COD behavior in dose response curves of BALB/c mice divided into a control group and animal model of asthma (OVA) and offer an alternative for moments that the constant phase model should not be applied. It was found an association between parameters excluded in the first five measures and doses (p = 0.0026) in the OVA. Eleven measurements were excluded at the last dose while in the first or in the second doses, only two. The relative risk to present excluded measures between the last and first or second doses was 5.5 and CI: 1.30 to 23.26. The problem about the differences found in these moments is that these are the measures associated to higher model parameter\'s values for each dose and traditionally are the values shown in scientific studies. The minimum, mean and maximal values of tracheal pressure behaved similarly on a inter group matter, presenting differences (p<0,05) at these doses: 0.3 and 1 mg/kg. The same pattern was observed for Rn . It is possible to use values of tracheal pressure instead of modeled parameters in moments that the constant phase model should not be applied, like low COD in moments of severe bronchoconstriction. This replacement of parameters through tracheal pressure is possible because tracheal pressure is not obtained via mathematical models but through mensuration. Therefore, as the Rn G e H parameters are obtained through mathematical modeling and not via direct mensuration, the poor adjustment means that these parameters should not be applied on the moments presented on this study. In addition, as an alternative it is possible to use pressure values measured as a variable of response, even if the pressure values are not able to distinguish between airway and parenchyma.

Page generated in 0.1012 seconds