Spelling suggestions: "subject:"séptico."" "subject:"séptimo.""
21 |
Isolamento, identificação e suscetibilidade in vitro de leveduras isoladas da cavidade oral de fêmeas caninas / Isolation, identification and in vitro susceptibility test of yeasts from oral cavity of female canineSANTIN, Rosema 26 February 2009 (has links)
Made available in DSpace on 2014-08-20T14:37:57Z (GMT). No. of bitstreams: 1
dissertacao_rosema_santin.pdf: 3641963 bytes, checksum: d088da2fe7dd18329508c62dfe97ec75 (MD5)
Previous issue date: 2009-02-26 / The aims of this study was the oral cavity evaluation of females stray dogs from
Pelotas-RS, as well as yeast isolation and identification from three different areas of
this cavity, comparison of two technique of sample collection (swabs and curettes)
and test the in vitro susceptibility of isolated yeasts against common oral antiseptics
used in pets. Fifty-nine randomized animals were included in the study. All of them
were SRD, without age defined and from Pelotas-RS. They were divided in three
groups of ages by the evaluation of dental arc, and were examined to determine the
cranial morphology, presence of dental plaque, tooth fractures, malocclusion,
halitosis and gingival bleeding. Measure of periodontal groove depth was also done.
Samples were collected from three areas, gingival mucosa, dental biofilm and
periodontal grooves, with different collection techniques: swab, curettes, millimeter
periodontal probe and cellulose polymers membranes. In vitro susceptibility tests by
microdilution methods was done with 15 of those yeasts against A product (0,12%
chlorhexidine gluconate, 0,12% benzalkonium chloride and 0,10% chlorophila
extract) and B product (0,2% benzalkonium chloride, 1% propolis and 0,5%
peppermint arome). It was also evaluated chemical principles of products in
separated, as chlorhexidine gluconate, benzalkonium chloride and propolis. Tooth
fractures was observed in higher proportion at animals with six or more years old
(p=0,0030). Dogs younger than 2 years old had lower rate of dental plaques than the
others groups (p=0,0000). The association of positive areas of yeast isolation with
age, tooth fracture, dental plaque, halitosis, gingival bleeding or malocclusion was
not statistically significant. Sixty-one yeasts were isolated, characterized by M.
pachydermatis (50,82%), Rhodotorula spp. (13,11%), C. albicans (4,92%), C.
catenulata (3,28%), C. famata (1,64%), C. guilliermondii (1,64%), C. parapsilosis
(1,64%), C. intermedia (1,64%), T. asahii (13,11%), T. mucoide (1,64%) and C.
albidus (6,56%), from 30 (50,85%) animals. Yeasts growing inhibition was observed
in all products tested and in all concentrations of them, with exception of propolis that
did not show activity against yeasts. In conclusion, at oral cavity exam of female
dogs, the mainly alterations found were dental plaques, tooth fractures and
malocclusion. Isolated yeasts are normal habitants from the three different areas of
oral cavity studied, without resulting in clinical signs. In relation to the techniques, it
was not found difference between swab and curettes for oral sample collection.
Yeast isolation was higher in female dogs that show halitosis. Oral antiseptics tested, as well as chlorhexidine gluconate and benzalkonium chloride were effective against
yeasts isolated from canine oral cavity in all dilution tested. Propolis, at the conditions
and dilutions tested, is not recommended as an oral antiseptic against yeast. / Objetivou-se avaliar a cavidade oral de fêmeas caninas errantes de Pelotas-RS,
isolar e identificar leveduras de três sítios desta cavidade, comparar duas técnicas
de colheita da mucosa gengival (swab e cureta) e testar a suscetibilidade in vitro
destas leveduras frente a anti-sépticos orais utilizados na rotina odontológica de
pequenos animais e seus princípios ativos. Foram avaliadas 59 fêmeas caninas,
errantes, SRD, provenientes de Pelotas/RS. Os animais foram selecionados
aleatoriamente, e distribuídos em três grupos de idade conforme avaliação da
arcada dentária. Estes foram avaliados quanto à conformidade cranial, presença de
cálculo dentário, fraturas dentárias, maloclusão, halitose, sangramento gengival e
mensuração da profundidade de sulco peridontal. As amostras foram obtidas da
mucosa gengival, biofilme dental e sulco periodontal, com diferentes formas de
coletas: swab, cureta, sonda periodontal milimetrada e ponta de membrana em éster
de celulose. O teste de suscetibilidade in vitro foi realizado pela técnica de
microdiluição em caldo testando o produto A (0,12% de gluconato de clorexidina,
0,12% de cloreto de benzalcônio e 0,10% de extrato de clorofila) e, o produto B
(0,2% de cloreto de benzalcônio, 1% de tintura de própolis e 0,5% de aroma hortelãpimenta)
frente a 15 leveduras isoladas. Também foram avaliados os princípios
ativos gluconato de clorexidina, cloreto de benzalcônio e tintura de própolis
isoladamente. As fraturas dentárias foram mais frequentes nos animais com seis
anos ou mais (p=0,0030). Nos cães com até dois anos a presença de cálculo
dentário aresentou-se com menor frequência (p=0,0000) em relação aos outros dois
grupos. Na relação entre o número de locais de isolamento com idade, conformidade
cranial, presença de fratura, cálculo dentário, halitose, sangramento gengival e
maloclusão não foi encontrada diferença estatisticamente significativa. Foram
isoladas 61 leveduras, M. pachydermatis (50,82%), Rhodotorula spp. (13,11%), C.
albicans (4,92%), C. catenulata (3,28%), C. famata (1,64%), C. guilliermondii
(1,64%), C. parapsilosis (1,64%), C. intermedia (1,64%), T. asahii (13,11%), T.
mucoide (1,64%) e C. albidus (6,56%) distribuídas em 30 (50,85%) animais. Foi
observada inibição do crescimento de todas as leveduras, em todos os produtos, em
todas as concentrações, com exceção da tintura de própolis que não demonstrou
ação nenhuma nas concentrações testadas. Sendo assim, na avaliação da cavidade
oral das fêmeas caninas predominaram presença de cálculo dentário, fraturas
dentárias e maloclusões. As leveduras isoladas fazem parte da microbiota dos diferentes sítios da cavidade oral das fêmeas caninas estudadas, estando
presentes sem causar alterações. O isolamento de leveduras foi maior naquelas
fêmeas que tinham halitose. Não houve diferença entre as técnicas utilizadas (swab
ou cureta) para colheita de material da mucosa gengival. Os anti-sépticos orais e os
compostos gluconato de clorexidina e o cloreto de benzalcônio foram eficazes frente
às leveduras isoladas da cavidade oral de fêmeas caninas em todas as
concentrações testadas, inclusive nas abaixo da recomendada para uso. Nas
condições estudadas, a tintura de própolis não é recomendada para utilização como
anti-séptico oral frente às leveduras nas concentrações estudadas.
|
22 |
Minimização de impactos nos recursos hídricos causados por sistemas de saneamento in situ: estudo piloto em Parelheiros - São Paulo (SP) / Minimization of septic systems impacts on groundwater resources. Pilot study in Parelheiros - São Paulo (SP)Suhogusoff, Alexandra Vieira 24 June 2010 (has links)
O escopo principal desse projeto foi o de criar um conjunto de ações integradas que permitissem minimizar os impactos de sistemas de saneamento in situ nos recursos hídricos subterrâneo. Sendo as fossas sépticas, mesmo as bem construídas, pouco efetivas onde há alta densidade populacional, foi desenvolvido e aplicado no loteamento Jardim Santo Antônio (situado na APA de Capivari-Monos, Parelheiros) um novo conceito de saneamento in situ: uma fossa alternativa melhorada com uso de barreiras reativas, que possibilitasse a degradação mais eficiente de nitrato e de microorganismos patogênicos. Para a degradação de microorganismos, o material reativo utilizado correspondeu ao BOF (Basic Oxygen Furnace - resíduo de altos fornos de fundição em siderúrgicas) e para a desnitrificação, a serragem. A barreira reativa para remoção de nitrato foi alvo de estudos desse projeto. Desenvolveu-se um questionário de avaliação de risco sanitário para uma área onde foram cadastrados 178 lotes, em um total de 218 poços e 182 fossas. A partir da análise dos dados por Cluster foi possível selecionar um conjunto de perguntas que estivessem mais relacionadas a riscos de contaminação por bactérias e nitrato. Observou-se que a relação entre as características de construção e operação dos poços pouco pode prever a contaminação por nitrato, o que evidencia que sua presença é de caráter regional, fruto de uma ocupação desordenada e densa. Em contrapartida, as perguntas tiveram maior relação com o parâmetro bactérias, o que implica em uma característica local (do poço em si). Antes da implantação da fossa alternativa melhorada, foram realizados experimentos de colunas de sedimentos em laboratório para se testar a eficiência de serragem na degradação de nitrato. Montaram-se 3 colunas: uma só com sedimentos da área, que correspondeu ao branco, e as outras duas com sedimentos e 10cm e 20cm de espessura de uma mistura de serragem (Cedrinho) com areia, respectivamente. Os resultados mostraram uma eficiência de degradação do nitrato de até 96,5% e 99,7% para as colunas de 10cm e 20cm. Foram instaladas duas fossas na área de estudo: a fossa alternativa melhorada com o uso de barreiras reativas (FA) e a fossa controle (FC), equivalente ao esgotamento usualmente empregado pela comunidade (ausência de materiais reativos). Na Fossa Alternativa, estruturada com as barreiras reativas contendo BOF (1m abaixo do tanque receptor do efluente) e serragem (abaixo do BOF, mas separada deste por 1m de pacote arenoso), é possível discriminar certos comportamentos ao longo de suas posições. O BOF que é rico em óxidos de cálcio e ferro confere ao efluente percolante uma condutividade elétrica mais acentuada e um pH muito básico, em torno de 12. Já a barreira com serragem caracterizou-se por concentrações de oxigênio dissolvido mais baixas e presença de C orgânico na forma dissolvida, condições necessárias para a ocorrência da desnitrificação do nitrato gerado perfil acima. No entanto, as concentrações de oxigênio não devem ter sido suficientemente baixas para uma maior eficiência na desnitrificação na barreira de serragem. Além disso, a eficiência pode ter sido comprometida pelo elevado pH que essa barreira foi submetida pelo efluente percolado antes no BOF, o que afetou a capacidade das bactérias desnitrificantes em suas reações metabólicas. Na Fossa Controle, os íons distribuíram-se ao longo do perfil de forma mais regular. A composição dessa fossa representa a fonte em si, com altas concentrações de N-amoniacal e de carbono orgânico dissolvido e baixas concentrações de oxigênio dissolvido. Para esse tipo de cenário, a nitrificação deve ocorrer na zona não-saturada abaixo da fossa, para que depois o nitrato possa alcançar o lençol freático. / The main purpose of this project was to create a set of integrated actions that could minimize impacts of septic systems on groundwater resources. Since the septic tanks, even the well-constructed ones, are not effective on areas where the population density is high, an alternative latrine improved with reactive barriers was developed and applied in Jardim Santo Antônio settlement (Parelheiros, São Paulo, SP). In order to degrade the microorganisms, the reactive material was BOF (Basic Oxygen Furnace) slag from steel producer facilities, and in order to enhance the denitrification, the material of the reactive barrier was sawdust. The sawdust barrier was the main issue in this project. A risk assessment questionnaire was developed and it was applied to an area where 178 residences were evaluated, totalizing 218 water wells and 182 latrines. A Cluster Analysis was used to select the questions that would be related to the risk of contamination by bacteria or nitrate. It was observed that the inapropriated construction and operation of the wells are poorly related to the level of nitrate contamination, what suggests that the nitrate contamination is a more regional problem. On the other hand, it was found a good relationship between the level of bacteria contaminations and the characteristics of construction and operation of the wells, what suggests that this contamination has a local factor. Before the installation of the enhanced septic tank, soil columns breakthrough experiments were conducted in laboratory to test the efficiency of sawdust in nitrate removal. Three soil columns were set up: one filled only with sediments of Jardim Santo Antonio settlement, and another two with the same kind of sediments and sawdust layers introduced with 10cm and 20cm thickness. The results showed an efficiency of sawdust to denitrification of 96,5% and 99,7%, respectively. Two septic tanks were installed in the study area: the alternative latrine enhanced with reactive barriers (AL), and the control latrine (CL), equivalent to the usual tanks founded on the area. In AL, structured with reactive barriers containing BOF (1m below the wastewater tank) and sawdust (under the BOF layer, but first separate from it by 1m of sand package), it\'s possible to discern few parameter behaviors. BOF, which is rich in calcium oxides and iron oxides, incrises the electrical conductivity and the pH of the effluent (~12). The sawdust barrier, in its turn, was characterized by low concentration of dissolved oxygen and by the presence of dissolved organic carbon, essential conditions denitrification ocurrence. The denitrification efficiency of the sawdust barrier was affected by the high pH observed in the effluent that crossed the BOF barrier, which perturbed the denitrifying bacteria performance. In CL, the vertical distribution of the ions was more regular. The samples from this system presented high levels of ammonium and DOC and low values for dissolved oxygen. For this case, the nitrification must happen in the unsaturated zone bellow the tank, so the nitrate formed can reach the groundwater.
|
23 |
AVALIAÇÃO DO PROCESSO DE CO-COMPOSTAGEM DE LODO DE TANQUE SÉPTICO UNIFAMILIAR E RESÍDUOS SÓLIDOS ORGÂNICOSMedeiros, Angela Carolina de 18 August 2009 (has links)
Made available in DSpace on 2015-09-25T12:23:38Z (GMT). No. of bitstreams: 1
Angela Carolina de Medeiros.pdf: 816809 bytes, checksum: ac7c00cad843d88070dc5e748e2319ca (MD5)
Previous issue date: 2009-08-18 / This study had the object of evaluating the influence of the frequency of aeration and
the quantity of structural material in the process of co-composting of sludge from
house septic tanks with residual organic solids. The research was carried out at the
Experimental Station for the Biological Treatment of Sewage (EXTRABES), in the city
Campina Grande, Paraiba during the period from August 2008 to July 2009. To
mount the experimental system of co-composting sludge was collected from the
house septic tanks in the district of Malhada da Roça, in the small town of São João
do Cariri, situated in the semi-arid region of the state of Paraiba. The residual organic
solids were collected from the Paraiba Company for Food and Agricultural Services
(EMPASA), Campina Grande, PB. The experimental system comprised a new
treatment of co-composting of sludge from house septic tanks with residual organic
solids using a process of turning over, with a frequency of 1, 2 and 3 times per week
with proportions of porous material of 4 and 8%. The monitoring period was for 112
days and weekly samples were collected for physic-chemical analysis and parasite
counts. The turning frequency did not have a significant effect on the transformation
of total volatile solids during the treatment period. The quantity of added structural
material directly influenced the efficiency of the transformation of dry mass which was
inversely proportional to the percentage of structural material added. The process of
co-composting showed efficient removal of helminthes eggs. The compost produced
met the legal requirements in relation to the quantities of macronutrients. The
efficiency of the co-composting system showed two distinct phases: namely rapid
during the first 35 days and a slow subsequent phase. The kinetic constants for
biodegradation were determined from adjusted exponential equations, and showed
higher values during the rapid phase and values approximately ten times lower
during for the slow phase. / O trabalho teve objetivo de avaliar a influência da freqüência de aeração e
quantidade de estruturante no processo de co-compostagem de lodo de tanque
séptico unifamiliar e resíduos sólidos orgânicos. A pesquisa foi realizada na Estação
Experimental de Tratamento Biológico de Esgoto (EXTRABES), na cidade de
Campina Grande-PB, durante o período de Agosto de 2008 a Julho de 2009. Para a
montagem do sistema experimental de co-compostagem foram coletados lodos de
tanques sépticos unifamiliar no distrito de Malhada da Roça, Município de São João
do Cariri, localizado no semi-árido paraibano. Os resíduos sólidos orgânicos foram
coletados na Empresa Paraibana de Alimentos e Serviços Agrícolas (EMPASA),
Campina Grande-PB. O sistema experimental foi constituído de nove tratamentos de
co-compostagem de lodo de tanque séptico unifamiliar e resíduos sólidos orgânicos,
realizando o processo de reviramento com freqüência de uma, duas e três vezes por
semana e percentagem de estruturante de 0, 4 e 8%. O monitoramento do sistema
experimental foi realizado durante 112 dias, e semanalmente eram coletadas
amostras para realização de análises físico-químicas e parasitológicas. A freqüência
de reviramento não apresentou influência significativa na transformação de STV nos
tratamentos estudados. O material estruturante influenciou diretamente no processo,
de modo que o comportamento da eficiência de transformação de massa seca foi
inversamente proporcional ao percentual de estruturante. O processo de cocompostagem
mostrou-se eficiente na remoção de ovos de helmintos. O adubo
produzido atendeu aos requisitos da legislação, com relação à quantidade de
macronutrientes. O desempenho do sistema de co-compostagem permitiu visualizar
duas fases distintas: rápida nos primeiros 35 dias e fase lenta nos dias
subsequentes. As constantes cinéticas de biodegradação foram determinadas a
partir de equações exponenciais ajustadas, apresentando valores maiores na fase
rápida, e valor aproximadamente dez vezes menor na fase lenta.
|
24 |
Minimização de impactos nos recursos hídricos causados por sistemas de saneamento in situ: estudo piloto em Parelheiros - São Paulo (SP) / Minimization of septic systems impacts on groundwater resources. Pilot study in Parelheiros - São Paulo (SP)Alexandra Vieira Suhogusoff 24 June 2010 (has links)
O escopo principal desse projeto foi o de criar um conjunto de ações integradas que permitissem minimizar os impactos de sistemas de saneamento in situ nos recursos hídricos subterrâneo. Sendo as fossas sépticas, mesmo as bem construídas, pouco efetivas onde há alta densidade populacional, foi desenvolvido e aplicado no loteamento Jardim Santo Antônio (situado na APA de Capivari-Monos, Parelheiros) um novo conceito de saneamento in situ: uma fossa alternativa melhorada com uso de barreiras reativas, que possibilitasse a degradação mais eficiente de nitrato e de microorganismos patogênicos. Para a degradação de microorganismos, o material reativo utilizado correspondeu ao BOF (Basic Oxygen Furnace - resíduo de altos fornos de fundição em siderúrgicas) e para a desnitrificação, a serragem. A barreira reativa para remoção de nitrato foi alvo de estudos desse projeto. Desenvolveu-se um questionário de avaliação de risco sanitário para uma área onde foram cadastrados 178 lotes, em um total de 218 poços e 182 fossas. A partir da análise dos dados por Cluster foi possível selecionar um conjunto de perguntas que estivessem mais relacionadas a riscos de contaminação por bactérias e nitrato. Observou-se que a relação entre as características de construção e operação dos poços pouco pode prever a contaminação por nitrato, o que evidencia que sua presença é de caráter regional, fruto de uma ocupação desordenada e densa. Em contrapartida, as perguntas tiveram maior relação com o parâmetro bactérias, o que implica em uma característica local (do poço em si). Antes da implantação da fossa alternativa melhorada, foram realizados experimentos de colunas de sedimentos em laboratório para se testar a eficiência de serragem na degradação de nitrato. Montaram-se 3 colunas: uma só com sedimentos da área, que correspondeu ao branco, e as outras duas com sedimentos e 10cm e 20cm de espessura de uma mistura de serragem (Cedrinho) com areia, respectivamente. Os resultados mostraram uma eficiência de degradação do nitrato de até 96,5% e 99,7% para as colunas de 10cm e 20cm. Foram instaladas duas fossas na área de estudo: a fossa alternativa melhorada com o uso de barreiras reativas (FA) e a fossa controle (FC), equivalente ao esgotamento usualmente empregado pela comunidade (ausência de materiais reativos). Na Fossa Alternativa, estruturada com as barreiras reativas contendo BOF (1m abaixo do tanque receptor do efluente) e serragem (abaixo do BOF, mas separada deste por 1m de pacote arenoso), é possível discriminar certos comportamentos ao longo de suas posições. O BOF que é rico em óxidos de cálcio e ferro confere ao efluente percolante uma condutividade elétrica mais acentuada e um pH muito básico, em torno de 12. Já a barreira com serragem caracterizou-se por concentrações de oxigênio dissolvido mais baixas e presença de C orgânico na forma dissolvida, condições necessárias para a ocorrência da desnitrificação do nitrato gerado perfil acima. No entanto, as concentrações de oxigênio não devem ter sido suficientemente baixas para uma maior eficiência na desnitrificação na barreira de serragem. Além disso, a eficiência pode ter sido comprometida pelo elevado pH que essa barreira foi submetida pelo efluente percolado antes no BOF, o que afetou a capacidade das bactérias desnitrificantes em suas reações metabólicas. Na Fossa Controle, os íons distribuíram-se ao longo do perfil de forma mais regular. A composição dessa fossa representa a fonte em si, com altas concentrações de N-amoniacal e de carbono orgânico dissolvido e baixas concentrações de oxigênio dissolvido. Para esse tipo de cenário, a nitrificação deve ocorrer na zona não-saturada abaixo da fossa, para que depois o nitrato possa alcançar o lençol freático. / The main purpose of this project was to create a set of integrated actions that could minimize impacts of septic systems on groundwater resources. Since the septic tanks, even the well-constructed ones, are not effective on areas where the population density is high, an alternative latrine improved with reactive barriers was developed and applied in Jardim Santo Antônio settlement (Parelheiros, São Paulo, SP). In order to degrade the microorganisms, the reactive material was BOF (Basic Oxygen Furnace) slag from steel producer facilities, and in order to enhance the denitrification, the material of the reactive barrier was sawdust. The sawdust barrier was the main issue in this project. A risk assessment questionnaire was developed and it was applied to an area where 178 residences were evaluated, totalizing 218 water wells and 182 latrines. A Cluster Analysis was used to select the questions that would be related to the risk of contamination by bacteria or nitrate. It was observed that the inapropriated construction and operation of the wells are poorly related to the level of nitrate contamination, what suggests that the nitrate contamination is a more regional problem. On the other hand, it was found a good relationship between the level of bacteria contaminations and the characteristics of construction and operation of the wells, what suggests that this contamination has a local factor. Before the installation of the enhanced septic tank, soil columns breakthrough experiments were conducted in laboratory to test the efficiency of sawdust in nitrate removal. Three soil columns were set up: one filled only with sediments of Jardim Santo Antonio settlement, and another two with the same kind of sediments and sawdust layers introduced with 10cm and 20cm thickness. The results showed an efficiency of sawdust to denitrification of 96,5% and 99,7%, respectively. Two septic tanks were installed in the study area: the alternative latrine enhanced with reactive barriers (AL), and the control latrine (CL), equivalent to the usual tanks founded on the area. In AL, structured with reactive barriers containing BOF (1m below the wastewater tank) and sawdust (under the BOF layer, but first separate from it by 1m of sand package), it\'s possible to discern few parameter behaviors. BOF, which is rich in calcium oxides and iron oxides, incrises the electrical conductivity and the pH of the effluent (~12). The sawdust barrier, in its turn, was characterized by low concentration of dissolved oxygen and by the presence of dissolved organic carbon, essential conditions denitrification ocurrence. The denitrification efficiency of the sawdust barrier was affected by the high pH observed in the effluent that crossed the BOF barrier, which perturbed the denitrifying bacteria performance. In CL, the vertical distribution of the ions was more regular. The samples from this system presented high levels of ammonium and DOC and low values for dissolved oxygen. For this case, the nitrification must happen in the unsaturated zone bellow the tank, so the nitrate formed can reach the groundwater.
|
25 |
Tecnologia alternativa para tratamento seletivo de efluentes domésticos / Alternative technology for selective treatment of domestic sewagePizzatto, Gabriele 24 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:07:58Z (GMT). No. of bitstreams: 1
Gabriele Pizzatto.pdf: 2509942 bytes, checksum: 2ced823abdb0d261ba88e1b1559d76a3 (MD5)
Previous issue date: 2012-02-24 / The effluent from the kitchen sink, dishwasher, tank/washing machine, toilet bowl, shower, sink and tub when not covered are the source of many environmental problems and public health. The current management models based on conventional technologies still present technical and economic limitations. In this context, the study aimed to develop and propose a new model of management of domestic sewage and specifically the development of an alternative technology for the preliminary treatment of wastewater generated in the kitchen sink (due to its specific characteristics). The methodology included the qualitative and quantitative characterization of the generating source and domestic effluents, methods of collection, transportation and conventional treatment of domestic sewage and explanation of the advantages/disadvantages of the methods, processes and conventional technology. The results of the monitoring activities and habits of a family allowed determining the water consumption and the consequent generation of waste in each of the sources, which resulted in a correlation that will assist in the calculation of generation capacity/production of domestic sewage in homes and corresponding diagnosis. The tests performed with commercially available technologies for treating the effluent from the kitchen sink (grease trap) have identified the technical limitations of these technologies and the consequence was that the development of a new technology with innovative features called "ash for treatment of effluent from the sink kitchen with simultaneous separation of fat and settleable solids - Model UNIOESTE" innovative technology and in the process of patenting. It therefore contributes to mitigating the negative impacts that result from inadequate management of domestic wastewater using for such technological innovations resulting from intellectual activity with experimental validation.
Key-words: domestic sewage, effluent from the kitchen sink, waste management, grease trap. / Os efluentes domésticos provenientes da pia da cozinha, máquina de lavar louça, tanque/máquina de lavar roupas, bacia sanitária, chuveiro, lavatório e banheira quando não tratados são fonte de muitos problemas ambientais e de saúde pública. Os atuais modelos de gestão com base de tecnologias convencionais ainda apresentam limitações técnicas e econômicas. Nesse contexto, o trabalho objetivou o desenvolvimento e proposição de um novo modelo de gestão de efluentes domésticos e especificamente o desenvolvimento de uma tecnologia alternativa para o tratamento preliminar do efluente gerado na pia da cozinha (devido às suas características peculiares). A metodologia contemplou a caracterização qualitativa e quantitativa da fonte geradora e dos efluentes domésticos, dos métodos de coleta, transporte e tratamento convencional de efluentes domésticos e explicitação das vantagens/desvantagens dos métodos, processos e da tecnologia convencional. Os resultados do monitoramento das atividades e hábitos de uma família permitiram determinar o consumo de água e a conseqüente geração de efluentes em cada uma das fontes, cujo resultado foi uma correlação que deverá auxiliar no cálculo da capacidade de geração/produção de efluentes domésticos nas residências e o correspondente diagnóstico. Os testes realizados com tecnologias disponíveis no mercado para tratamento do efluente da pia da cozinha (caixa de gordura) permitiram identificar as limitações técnicas dessas tecnologias e a conseqüência disso foi o desenvolvimento de uma nova tecnologia com características inovadoras denominada Caixa para tratamento de efluente da pia da cozinha com separação simultânea de gordura e sólidos sedimentáveis Modelo UNIOESTE , de tecnologia inovadora e em fase de patenteamento. Desta forma, contribui-se com a mitigação dos impactos negativos que resultam da gestão inadequada dos efluentes domésticos utilizando-se para tal, inovações tecnológicas resultantes da atividade intelectual com validação experimental.
|
Page generated in 0.0603 seconds