• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 5
  • 2
  • Tagged with
  • 57
  • 28
  • 22
  • 20
  • 19
  • 19
  • 17
  • 17
  • 16
  • 13
  • 11
  • 10
  • 10
  • 10
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estruturas de edifícios em concreto armado submetidas a ações de construção / Multistory reinforced concrete structures under construction loads

José Fernão Miranda de Almeida Prado 13 December 1999 (has links)
As ações presentes durante a construção de estruturas de edifícios em concreto armado são significantemente influenciadas pelo processo construtivo e podem ultrapassar a capacidade resistente definida no projeto estrutural. Os pavimentos recém concretados são suportados por pavimentos previamente concretados, através de um sistema de fôrmas, escoras e reescoras. Se houver fissuração prematura os pavimentos terão maiores deformações ao longo do tempo. Assim sendo, o trabalho apresenta um procedimento de análise estrutural que leva em conta a seqüência natural de construção. A definição das ações nos pavimentos durante a construção estabelece a história de carregamentos dos elementos estruturais do início ao fim da obra. Os modelos tridimensionais (utilizando o método dos elementos finitos) aqui apresentados consideram que o tempo altera as propriedades de resistência e deformabilidade do concreto antes dos 28 dias. Com isso, é definido um novo método para a determinação da distribuição das ações de construção entre o sistema de escoramento e os pavimentos interligados (Método Aproximado). Além disso, propõe-se uma nova metodologia para verificação dos estados limites considerando a existência das etapas de construção. / The loads during construction of multistory reinforced concrete structures are significantly influenced by the construction schedule and can exceed the supporting structure\'s design capacity. The fresh floors are supported by previously cast floors, through a system of forms, shores and reshores. If cracked prematurely, the floors will have larger time-dependent deflections. Then, the text presents a procedure for structural analysis that takes into account the natural sequence of construction. Definition of the loads on floors during construction provides a view of the history of structural element loads from the beginning to the end of construction work. The tridimensional models (using the finite element method) presented herein considers that the time affects the strenght and deformability properties of concrete before 28 days. Then, a new method for determining how the construction loads are distributed among the shoring system and the interconnected floors is defined (Approximated Method). Further, a new methodology for the limit states verification taking into account the construction phases is proposed.
32

Definição do ciclo operacional de um reator seqüencial em batelada aeróbio (SBR) para tratamento de esgoto sanitário / Definition of the operational cycle of an aerobic sequencing batch reactor (SBR) for the treatment of sanitary sewage

Rodrigo Gibbin Marconi 19 January 2001 (has links)
No processo de lodos ativados por batelada, a definição de um ciclo operacional é de fundamental importância para o bom funcionamento de uma estação de tratamento de esgotos que utiliza esse tipo de tratamento. A adoção de um ciclo adequado pode trazer vários benefícios como o aumento da eficiência de tratamento, a introdução da remoção da matéria nitrogenada, por meio dos processos de nitrificação e desnitrificação do efluente e até diminuir o consumo de energia que é relativamente alto nesse tipo de tratamento. Foi aplicada então, a definição do ciclo operacional à ETE Bueno de Andrada que utiliza o processo de lodos ativados por batelada aeróbio para o tratamento da fase líquida. Foram experimentados alguns ciclos de operação com tempos e estratégias diferentes, variando-se os tempos de aeração, mistura, enchimento ou sedimentação. A aplicabilidade de cada estratégia de ciclo foi avaliada em termos da eficiência de remoção da matéria orgânica carbonácea, retratada com as análises de DBO e DQO do esgoto afluente e do efluente final. Foi desenvolvido também, o processo de automação da ETE Bueno de Andrada com o estudo e ajuste de um programa computacional que gera um arquivo de controle utilizado para controle do ciclo de operação dos SBRs. Os resultados mostraram que os ciclos operacionais entre 10 e 12h, consegue-se uma eficiência de remoção da matéria orgânica carbonácea entre 95 e 97%. / The definition of an adequate operational cycle for the batch activated sludge process is of fundamental importance for the proper operation of a sewage treatment plant. The use of a suitable cycle can bring many benefits namely the increase of the treatment efficiency, the introduction of the nitrogen organic material removal through the nitrification and denitrification process of the eflluent and the decrease of energy consumption that is relatively high in this process. The operational cycle definition is then applied to the Sewage Treatment Plant of Bueno de Andrada that use the aerobic batch activated sludge process for the liquid phase treatment. Some operational cycles are experimented with different times and strategies, changing the aeration, rnixture, filling or sedimentation times. The applicability of each cycle strategy was checked by the carbon organic material removal efficiency, measured through the BOD and COD analyses of the influent sewage and the treated eflluent. It was developed, too, the automation process of the Sewage Treatment Plant of Bueno de Andrada, cornplementing and adjusting the control computer program for the PLC that controls the SBRs operational cycle. The results showed that with operational cycles between 10 and 12 hours, the removal efficiency of the carbon organic material was between 95 and 97%.
33

Uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas / Use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry

Allan Cezar Vieira dos Santos 09 June 2006 (has links)
Esta dissertação descreve o uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas. O estudo indicou que na faixa de pH entre 4 e 6 não há diferença entre a utilização de vermiculita expandida ou não-expandida na remoção dos íons. Observou-se que nos pH\'s avaliados o tempo de interação de 180 minutos foi suficiente para que o sistema atingisse o equilíbrio. Pode-se afirmar que a vermiculita não expandida apresenta as seguintes ordens de afinidade pelo cátions considerados: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). Nas condições de trabalho, os ensaios envolvendo a coluna de vermiculita não evidenciaram uma melhor capacidade de extração dos íons estudados frente ao sistema de extração em batelada. Percentuais de extração da ordem de 76% em amostra de efluente no sistema em batelada reforçam a viabilidade do uso da vermiculita como adsorvente destes metais. Um método SIA-ASV (análise por injeção seqüencial - voltametria de redissolução anódica) foi proposto e validado. Para um tempo de deposição de 80 s e vazão de 10 µLs-1, os limites de detecção foram 0,06, 0,09 e 0,16 µmolL-1 para Cd, Pb e Cu, respectivamente, além de apresentar uma faixa linear de trabalho entre 0,2 e 9,0 µmolL-1. / This dissertation describes the use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry. The study indicated that under pH range from 4 to 6 there is no difference on using expanded or not expanded vermiculite for removal of ions. It was also observed that at any evaluated pH, a 180 minutes interaction time was long enough to allow the system reach equilibrium. It\'s possible to state that non-expanded vermiculite presents the following affinity orders by the studied ions: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). At working conditions, tests involving vermiculite columns didn\'t show a better performance on extracting these ions when faced to batch extraction systems. Extraction percentuals of about 76% were obtained using a sample of coatings industry wastewater, reinforcing the viability of the use of vermiculite as an adsorbent of these metals. A SIA-ASV (sequential injection analysis - anodic stripping voltammetry) method was proposed and validated. For a deposition time of 80 s and a flow rate of 10 µL s-1, detection limits were 0.06, 0.09 and 0.16 µmol L-1 to Cd, Pb and Cu, respectively; a linear working range, between 0.2 and 9.0 µmol L-1 was also determined.
34

Influência da estratégia de alimentação no desempenho do reator anaeróbio em batelada seqüencial contendo biomassa imobilizada / Influence of feeding strategy on the performance of anaerobic sequencing batch reactor containing immobilized biomass

Alisson Carraro Borges 07 April 2003 (has links)
Submeteu-se um reator anaeróbio operado em batelada seqüencial a diferentes tempos de enchimento, com o objetivo de verificar-se o desempenho do sistema. O reator, construído em acrílico e com capacidade de 6,3 L, tratou por ciclo um volume de 2,5 L de esgoto sintético com concentração de aproximadamente 500 mgDQO/L. O sistema foi operado à temperatura de 30 graus mais ou menos 1, com duração de 8 h para cada ciclo (tC) e agitação de 500 rpm implementada mecanicamente. Cubos de espuma de poliuretano foram usados como suporte para imobilização da biomassa. No início de cada ciclo, o reator foi carregado com 60 % do volume do esgoto; o restante foi preenchido durante tempos de enchimento (tF) que caracterizaram as diferentes estratégias de alimentação. Os resultados obtidos demonstram que para razões tF/tC <= 0,5 o sistema alcança médias de remoção de matéria orgânica acima de 75 % e 70% para amostras filtradas e não filtradas, respectivamente. Nos ensaios em que tF/tC > 0,5, registrou-se perda na eficiência e formação de polímeros extracelulares, apesar da estabilidade observada. O estudo contribuiu para o melhor entendimento do sistema e definição de técnicas de operação em futuras aplicações. / An anaerobic sequencing batch reactor was operated at different fill times with the objective to asses system performance. The reactor, made of plexiglas and with a capacity of 6.3 L, treated per cycle 2.5 L of synthetic wastewater with a concentration of nearly 500 mgCOD/L. The system was operated at a temperature of 30oC, with 8-h cycles (tC) and mechanical agitation rate of 500 rpm. Cubic particles of polyurethane foam were used as support material for anaerobic biomass immobilization. At the start of each cycle, the reactor was fed with 60 % of the wastewater volume, the remainder was filled at different feeding times (tF) that characterized the different feeding strategies. The results obtained showed that for a ratio of tF/tC <= 0.5 the system attained average filtered and non-filtered substrate removal efficiency of 75 % and 70 %, respectively. Ratios of tF/tC > 0.5, resulted in loss in efficiency and formation of extra cellular polymers, in spite of system stability. The study contributed to a better understanding of the system and definition of operational techniques for future applications.
35

Influência do tipo de impelidor sobre o desempenho do reator anaeróbio em batelada seqüencial com biomassa granulada tratando esgoto sintético / Influence of the impeller type on the performance of the anaerobic sequencing batch reactor with granulated biomass treating synthetic wastewater

Rogério Michelan 10 February 2006 (has links)
Em um reator de fundo redondo e volume útil de 5 L tratando esgoto sintético com carga orgânica de 800 mgDQO.'L POT.-1' com biomassa granulada a influência do tipo de escoamento e velocidade rotacional foi investigada com o uso de cinco impelidores sendo eles turbina e pá de seis pás planas verticais, turbina e pá de seis pás planas inclinadas 45 graus e hélice, comumente aplicados em processos biológicos. Foi também investigada a viabilidade de implementação de tubo de tiragem ao reator em conjunto com os impelidores tipo hélice e tipo pá de pás planas inclinadas alternadamente, com vistas a melhorar a mistura e conseqüente transferência de massa no meio reacional. Os resultados mostram que a alteração do tipo de impelidor e as variações da velocidade rotacional não exerceram influência significativa sobre a estabilidade e desempenho dos sistemas estudados. Entretanto a análise das constantes do modelo cinético de primeira ordem mostrou que a alteração na velocidade rotacional exerceu influência de aumento dos valores das constantes, demonstrando com isto que o aumento da velocidade rotacional melhora a transferência de massa sólido-líquido no meio reacional. A análise das constantes cinéticas também demonstrou que a promoção de escoamento axial em reatores agitados mecanicamente é preferível ao escoamento radial quando comparados os impelidores tipo pá de pás planas verticais e de pás planas inclinadas. A presença do tubo de tiragem demonstrou incrementar significativamente a transferência de massa, através do aumento dos valores numéricos das constantes utilizadas no ajuste do modelo cinético de primeira ordem aos valores experimentais. A potência consumida foi inferior a 1,6.'10 POT.-3' HP/'M POT.3' com rotações abaixo de 200 rpm e os impelidores axiais consumiram 75% a menos de potência do que os radiais / The effect of flow type and rotor speed were investigated in a round-bottom reactor with 5 L useful volume containing granular biomass and treating synthetic wastewater with organic load of 800 mgCOD.'L POT.-1'. Five impellers have been used to this end, namely: turbine and paddle with six-vertical-flat blade, turbine and paddle with six-45 degrees-inclined-flat-blade and helix, commonly used in biological processes. Utilization of a draft tube together with the helix and six-alternately-inclined-flat-blade impellers was also assessed as a means to improve mixing and consequently mass transfer in the reaction medium. Results showed that altering impeller type and variation in rotor speed did not exert significant effect on the stability and performance of the investigated systems. However, analysis of the first order kinetic model constants showed that alteration in rotor speed resulted in increase in the values of the constants, demonstrating that increase in rotor speed improves solid-liquid mass transfer in the reaction medium. Analysis of the kinetic constants also showed that axial flow in mechanically stirred reactors is preferable over radial flow when the vertical flat blade impeller is compared to the inclined flat blade impeller. The presence of the draft tube showed significant improvement in mass transfer, which could be seen by the increase in the values of the constants used in the fit of the first order kinetic model to the experimental values. The power consumed was less than 1.6.'10 POT.-3' HP/'M POT.3' at rotor frequency below 200 rpm and the axial impellers consumed 75% less power than the radial ones
36

Influência da carga orgânica e do tempo de enchimento sobre o desempenho do reator anaeróbio em batelada seqüencial com biomassa granulada tratando soro de queijo / Effect of organic load and fill time on stability and efficiency of an ASBR containing granular biomass treating cheese whey

Thiago Ruiz Zimmer 10 February 2006 (has links)
Avaliou-se a influência da carga orgânica volumétrica (COV) aplicada e do tempo de enchimento sobre a estabilidade e a eficiência do ASBR com biomassa granulada, operado em batelada e batelada alimentada seqüenciais, tratando soro de queijo diluído. Os ensaios foram realizados a 30 'graus' C com volume total de meio de 5,0 litros e tempo de ciclo de 8 horas. Na primeira etapa realizou-se a operação em batelada com tempo de enchimento ('T IND.alim') de 10 min e freqüência de agitação de 150 rpm. A cada ciclo foram alimentados 2,0 litros de meio com concentração afluente ('C IND.AF') de 1000, 2000, 4000 e 6000 mg/L, em termos de DQO. A suplementação de alcalinidade foi gradualmente otimizada partindo-se da proporção de 1 a 0,25 da razão 'NA'H'CO IND.3'/DQO. Nestas condições foi possível operar o reator com estabilidade a COV aplicada de 4,8 g/L.d , com suplementação de alcalinidade de 25% e eficiência em remoção de matéria orgânica de 96,0% e 98,4% em termos de DQO filtrada e total, respectivamente. Na segunda etapa devido a problemas operacionais desenvolveram-se dispositivos para assegurar a retenção da biomassa a fim de viabilizar a operação em batelada alimentada. Os dispositivos testados foram ASBR híbrido, sistema de agitação com 2 impelidores, hélice e pá-inclinada (a) e hélice e turbina inclinada (b). A solução utilizada foi hélice e turbina inclinada. Para essa configuração, diminuiu-se a freqüência de agitação para 75 rpm e reduziu-se o volume de biomassa para 1,0 L. Dessa forma foi possível avaliar a influência das estratégias de alimentação ('T IND.alim') de 360, 180 e 10 minutos a COV aplicada constante de 2,4 g/L.d, para 'C IND.AF' de 4000 mg/L e 'V IND.alim' de 1,0 L e para 'C IND.AF' de 8000 mg/L e 'V IND.alim' de 0,5 L. Para a 'C IND.AF' de 4000 mg/L o aumento de 'T IND.alim' resultou em diminuição da eficiência, em termos de DQO solúvel, sendo de 97,8 , 96,7 e 94,5% para os 'T IND.alim' de 10, 180 e 360 minutos, respectivamente. Para a 'C IND.AF' de 8000 mg/L o aumento do 'T IND.alim' resultou em menores valores de DQO total no efluente / The effect of volumetric organic load (VOL) and fill time on the stability and efficiency of an ASBR was assessed. The ASBR containing granular biomass was operated in batch and fed-batch mode and treated diluted cheese whey. Assays were performed at 30 'degrees' C with total medium volume of 5.0 liters and 8-h cycle lengths. In a first stage the reactor was operated batch-wise with fill time ('T IND.feed') of 10 min and agitation frequency of 150 rpm. At each cycle 2.0 liters of medium were fed at influent concentration ('C IND.infl') of 1000, 2000, 4000 and 6000 mg/L, in terms of COD. Alkalinity supplementation was gradually optimized from 100% to 25% of 'NA'H'CO IND.3'/COD ratio. At these conditions the reactor attained stability at applied VOL of 4.8 g/L.d, alkalinity supplementation of 25% and organic matter removal efficiency of 96.0% and 98.4% in terms of soluble and total COD, respectively. In a second stage due to operational problems devices were developed to assure biomass retention and hence make fed-batch operation feasible. The tested devices included hybrid ASBR, agitation system with two impellers: helix and inclined blade impeller (a) and helix and inclined turbine impeller (b). The system chosen was the helix and inclined turbine. With this configuration agitation frequency and biomass volume were reduced to 75 rpm and 1.0 L, respectively. This way, it was possible to assess feed strategies ('T IND.feed') of 360, 180 and 10 minutes at constant applied VOL of 2.4 g/L.d, for 'C IND.infl' of 4000 mg/L at 'V IND.feed' of 1.0 L and for 'C IND.infl' of 8000 mg/L at 'V IND.feed' of 0.5 L. At 'C IND.infl' of 4000 mg/L increase in 'T IND.feed' resulted in decrease in efficiency in terms of soluble COD, which amounted to 97.8, 96.7 and 94.5% for 'T IND.feed' of 10, 180 and 360 minutes, respectively. At 'C IND.infl' of 8000 mg/L the increase in 'T IND.feed' resulted in lower values for COD effluent
37

Determinação sequencial de cromo, tálio, cádmio,chumbo, cobre e antimônio em concentrado polieletrolítico para hemodiálise por voltametria de redissolução através de um gradiente de pH / Sequential determination of chromium, thallium, cadmium, lead, copper and antimony in salinec hemodialysis concentrates by stripping voltammetry using electrolyte pH gradient

Schneider, Alexandre Batista 05 February 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The sequential voltammetric determination of chromium, thallium, cadmium, lead, copper and antimony, present as contaminants in dialysate concentrates (CPHD), is presented herein. These concentrates contain a very high chloride concentration (ca. 3.8 mol L-1), which makes difficult the direct analysis, without pretreatment, by many analytical techniques, like atomic absorption spectrometry and chromatography. The experimental conditions were varied in order to improve the peak resolution, selectively and sensitivity. The method is based on the gradual decrease on the pH of the solution present in the voltammetric cell, so that, the sequential determination of the analytes was possible. At pH 6 6.2, Cr determination was carried out with DTPA by catalytic adsorptive stripping voltammetry (CAdSV). Afterwards, the pH was adjusted at 4.8 ± 0.2 to determine thallium by anodic stripping voltammetry (ASV). At this pH, DTPA is non interfering specie for Tl-determination and, additionally, it masks the main interfering species for thallium (lead and cadmium). Cadmium, lead and copper were assayed by ASV after setting the pH to 1.5 ± 0.5. Under these conditions, DTPA releases these three metallic species from the previously built complexes, so that they behave as free species to react on the HMDE-surface. By setting with HCl the pH to values around zero antimony was assayed by ASV. At this acidity and in presence of high chloride concentrations antimony can be assayed with high sensitivity. The method was used for analysis of commercial samples of CPHDs and the found concentration varied from < LD until 140 Ug L-1. / A Determinação sequencial de cromo, tálio, cádmio, chumbo e cobre e antimônio em concentrado polieletrolítico para hemodiálise (CPHD) é descrita. Estes concentrados contêm uma concentração extremamente alta de íons cloreto (cerca de 3,8 mol L-1), o que torna difícil a análise direta por muitas técnicas analíticas. As condições experimentais foram variadas a fim de aumentar a resolução de pico, seletividade e sensibilidade. O método é baseado no decréscimo gradual do pH da solução presente na célula voltamétrica, o que possibilitou a determinação sequencial dos analitos. Em pH 6 6,2, a determinação de Cr foi realizada com DTPA por voltametria catalítico-adsortiva de redissolução (CAdSV). Em seguida, o pH foi ajustado para 4,8 ± 0,2 para determinar Tl por voltametria de redissolução anódica (ASV). Neste pH, DTPA não é uma espécie interferente na determinação de Tl e, adicionalmente, ele mascara as principais espécies interferentes para tálio (chumbo e cádmio). Cádmio, chumbo e cobre foram determinados por ASV após ajuste do pH a 1,5 ± 0,5. Sob estas condições, estas três espécies são liberadas em solução a partir dos complexos com DTPA previamente formados, de modo que elas se comportam como espécies livres para reagir na superfície do HMDE. Diminuindo-se o pH da solução para < 0 com HCl, foi determinado antimônio por ASV. Nesta acidez e na presença de uma alta concentração de cloretos, Sb pode ser medido com uma alta sensibilidade. O método foi utilizado para a análise de amostras de CPHD comerciais e as concentrações encontradas dos analitos variaram de < LD até 140 Ug L-1.
38

Tratamento de lixiviados de aterros sanitários em sistema de reatores anaeróbio e aeróbio operados em batelada seqüencial / Landfill leachate treatment in sequence anaerobic and aerobic batch reactors systems

Contrera, Ronan Cleber 06 June 2008 (has links)
Este trabalho avaliou a tratabilidade dos lixiviados do aterro sanitário de São Carlos-SP, utilizando-se reatores biológicos. O experimento foi conduzido à temperatura ambiente, em uma unidade piloto construída no aterro sanitário de São Carlos-SP. Inicialmente foram testados e comparados dois tipos de reatores anaeróbios, cada um com volume total de 1.200 L e ambos providos de agitação mecânica, diferenciando-se pelo tipo de imobilização da biomassa, sendo o primeiro com biomassa auto-imobilizada (ASBR) e o segundo com biomassa imobilizada em espuma de poliuretano (ASBBR). Um filtro biológico anaeróbio contínuo de fluxo ascendente de aproximadamente 120 L também foi avaliado. Além do pré-tratamento anaeróbio, foi avaliado também o pós-tratamento, que consistiu em um sistema de lodos ativados em batelada seqüencial de aproximadamente 180 L. O ASBR, inoculado com lodo granular de reator UASB, apresentou-se ineficiente, com problemas de desagregação e sedimentação da biomassa. O ASBBR, inoculado com lodo proveniente do fundo de uma lagoa de lixiviados, ao final de sua adaptação, apresentou eficiências superiores a 70%, em termos de remoção de DQO, utilizando-se lixiviado sem diluição, com DQO afluente da ordem de 11.000 mg/L, relação AVT/DQO aproximadamente igual a 0,6 e tempo de reação igual a 7 dias. Verificou-se que a biodegradabilidade anaeróbia dos lixiviados está diretamente relacionada à relação AVT/DQO, e que para relações AVT/DQO Total inferiores a 0,25, a biodegradabilidade é baixa, para relações entre 0,25 e 0,40 é média, e acima de 0,40 pode ser considerada elevada. Observou-se também que concentrações de N-amoniacal, da ordem de até 4.500 mg/L, não impedem o tratamento anaeróbio, desde que a biomassa esteja devidamente adaptada. Aos perfis temporais de concentração, realizados no ASBBR, foi ajustado um modelo de primeira ordem para consumo de substrato, na forma de DQO Total, obtendo valores de K1 variando entre 3,18 x \'10 POT.-5\' e 5,82 x \'10 POT.-5\' /(d.mgSTV/L). O pós-tratamento dos efluentes do ASBBR foi avaliado em um sistema de lodos ativados em batelada seqüencial, que obteve eficiência máxima da ordem de 30% em termos de remoção de DQO, com DQO afluente da ordem de 5.000 mg/L. Quanto ao filtro biológico anaeróbio de fluxo ascendente, obteve-se eficiências superiores a 70%, ao ser alimentado com uma mistura de lixiviado recalcitrante e etanol acidificado, com DQO afluente da ordem de 20.000 mg/L. / This work evaluated the tractability of landfill leachate from São Carlos-SP, utilizing biological reactors. The experiment was conducted at environmental temperature, in a pilot scale unity constructed into the São Carlos-SP landfill area. Initially, it was compared and tested two kinds of anaerobic reactors, each one with 1.200 L of total volume and both provided of mechanical agitation, differing by the kind of biomass immobilization, having the first (ASBR), self-immobilized biomass, and the second (ASBBR), immobilized biomass in polyurethane foam cubes. An approximately 120 L volume continuous up flow anaerobic biofilter was also evaluated. Additionally to the anaerobic treatment, it was also evaluated the post-treatment of landfill leachate in a sequence batch activated sludge system of 180 L. The ASBR, inoculated with a granular UASB sludge from a poultry wastewater treatment, was inefficient and presented sludge segregation and sedimentation problems. The ASBBR, inoculated using the sludge from the bottom of a landfill leachate reservoir, at the final of acclimation, presented efficiency over 70%, in terms of COD removal, utilizing landfill leachate without water dilution, with an inlet COD at the range of 11,000 mg/L, a TVA/COD ratio of approximately 0.6 and reaction time equal to 7 days. It was realized that the landfill leachate anaerobic biodegradability has a directly relationship to the TVA/COD ratio, and for TVA/COD Total ratio lower than 0.25, the biodegradability is low, for ratios between 0.25 and 0.40 is medium, and up to 0.40 may be considered high. It was also observed that \'NH IND.4\' POT.+\' concentrations at the range of 4,500 mg N/L has no significant interference in the anaerobic treatment, since the biomass has properly acclimated. At the temporal profiles of concentration performed in the ASBBR, it was adjusted a first order model for the substrate consumption, in terms of COD Total, obtaining K1 values ranging between 3.18 x \'10 POT.-5\' and 5.82 x \'10 POT.-5\' /(d.mgSTV/L). The post-treatment of the ASBBR effluents was evaluated in a sequence batch activated sludge system, which has obtained maximum efficiencies at the range of 30% in terms of COD removal, with an inlet COD at the range of 5,000 mg/L. As regards of the continuous up flow anaerobic biofilter, it has obtained efficiencies superiors to 70% when fed by a mixing of recovery landfill leachate and acidified ethanol, with an inlet COD at the range of 20,000 mg/L.
39

Otimização de estruturas reticuladas planas com comportamento geometricamente não linear / Optimization of plane frame structures with behavior geometrically nonlinear

ASSIS, Lilian Pureza de 20 October 2006 (has links)
Made available in DSpace on 2014-07-29T15:03:39Z (GMT). No. of bitstreams: 1 lilian pureza.pdf: 2774999 bytes, checksum: 2a074d04ee02c7e1c87fdbe8c2c68ef6 (MD5) Previous issue date: 2006-10-20 / The aim of this work is to present a formulation and corresponding computational implementation for sizing optimization of plane frames and cable-stayed columns considering geometric non liner behavior. The structural analysis is based on the finite element method using the updated lagrangian approach for plane frame and cable elements, which are represented by plane truss elements. The non linear system is solved by the Newton-Raphson method coupled to load increment strategies such as the arch length method and the generalized displacement parameter method, which allow the algorithm to transpose any critical point that happen to appear along the equilibrium path. In the optimization process the design variables are the heights of the crosssection of the frame elements, the objective function represents the volume of the structure and the constraints impose limits to displacements and critical load. Lateral constraints impose limits to the design variables. The finite difference method is used in the sensitivity analysis of the displacement and critical load constraints. The optimization process is carried out using three different optimization strategies: the sequential quadratic programming algorithm; the interior points algorithm; and the branch and bound method. Some numerical experiments are carried out so as to test the analysis and the sensitivity strategies. Numerical experiments are presented to show the validity of the implementation presented in this dissertation. / O objetivo deste trabalho é a otimização de dimensões de pórticos planos e de colunas estaiadas planas pela minimização do volume da estrutura, considerando os efeitos da não-linearidade geométrica em seu comportamento. A formulação utiliza, para análise das estruturas, elementos finitos de pórtico e de treliça planos e referencial lagrangeano atualizado. O método de Newton-Raphson foi utilizado como estratégia para solução do sistema de equações não lineares. Foram acopladas estratégias especiais para ultrapassagem de pontos críticos que possam existir ao longo da trajetória de equilíbrio, tais como o comprimento de arco cilíndrico e o controle dos deslocamentos generalizados. Na otimização, as variáveis de projeto são as alturas das seções transversais dos elementos, a função objetivo é o volume do material e as restrições dizem respeito a limitações impostas a deslocamentos e à carga limite, além de limitações impostas aos valores das variáveis. A sensibilidade da função objetivo foi obtida por diferenciação direta e a sensibilidade das restrições pelo método das diferenças finitas. Foram utilizados o algoritmo de programação quadrática seqüencial, PQS, o algoritmo de pontos interiores, PI, e o algoritmo de Branch and Bound, B&B. São apresentados exemplos de validação das estratégias de análise não linear e da análise de sensibilidade, além dos exemplos de validação da formulação empregada para a otimização resolvidos pelos métodos implementados.
40

Tratamento de lixiviados de aterros sanitários em sistema de reatores anaeróbio e aeróbio operados em batelada seqüencial / Landfill leachate treatment in sequence anaerobic and aerobic batch reactors systems

Ronan Cleber Contrera 06 June 2008 (has links)
Este trabalho avaliou a tratabilidade dos lixiviados do aterro sanitário de São Carlos-SP, utilizando-se reatores biológicos. O experimento foi conduzido à temperatura ambiente, em uma unidade piloto construída no aterro sanitário de São Carlos-SP. Inicialmente foram testados e comparados dois tipos de reatores anaeróbios, cada um com volume total de 1.200 L e ambos providos de agitação mecânica, diferenciando-se pelo tipo de imobilização da biomassa, sendo o primeiro com biomassa auto-imobilizada (ASBR) e o segundo com biomassa imobilizada em espuma de poliuretano (ASBBR). Um filtro biológico anaeróbio contínuo de fluxo ascendente de aproximadamente 120 L também foi avaliado. Além do pré-tratamento anaeróbio, foi avaliado também o pós-tratamento, que consistiu em um sistema de lodos ativados em batelada seqüencial de aproximadamente 180 L. O ASBR, inoculado com lodo granular de reator UASB, apresentou-se ineficiente, com problemas de desagregação e sedimentação da biomassa. O ASBBR, inoculado com lodo proveniente do fundo de uma lagoa de lixiviados, ao final de sua adaptação, apresentou eficiências superiores a 70%, em termos de remoção de DQO, utilizando-se lixiviado sem diluição, com DQO afluente da ordem de 11.000 mg/L, relação AVT/DQO aproximadamente igual a 0,6 e tempo de reação igual a 7 dias. Verificou-se que a biodegradabilidade anaeróbia dos lixiviados está diretamente relacionada à relação AVT/DQO, e que para relações AVT/DQO Total inferiores a 0,25, a biodegradabilidade é baixa, para relações entre 0,25 e 0,40 é média, e acima de 0,40 pode ser considerada elevada. Observou-se também que concentrações de N-amoniacal, da ordem de até 4.500 mg/L, não impedem o tratamento anaeróbio, desde que a biomassa esteja devidamente adaptada. Aos perfis temporais de concentração, realizados no ASBBR, foi ajustado um modelo de primeira ordem para consumo de substrato, na forma de DQO Total, obtendo valores de K1 variando entre 3,18 x \'10 POT.-5\' e 5,82 x \'10 POT.-5\' /(d.mgSTV/L). O pós-tratamento dos efluentes do ASBBR foi avaliado em um sistema de lodos ativados em batelada seqüencial, que obteve eficiência máxima da ordem de 30% em termos de remoção de DQO, com DQO afluente da ordem de 5.000 mg/L. Quanto ao filtro biológico anaeróbio de fluxo ascendente, obteve-se eficiências superiores a 70%, ao ser alimentado com uma mistura de lixiviado recalcitrante e etanol acidificado, com DQO afluente da ordem de 20.000 mg/L. / This work evaluated the tractability of landfill leachate from São Carlos-SP, utilizing biological reactors. The experiment was conducted at environmental temperature, in a pilot scale unity constructed into the São Carlos-SP landfill area. Initially, it was compared and tested two kinds of anaerobic reactors, each one with 1.200 L of total volume and both provided of mechanical agitation, differing by the kind of biomass immobilization, having the first (ASBR), self-immobilized biomass, and the second (ASBBR), immobilized biomass in polyurethane foam cubes. An approximately 120 L volume continuous up flow anaerobic biofilter was also evaluated. Additionally to the anaerobic treatment, it was also evaluated the post-treatment of landfill leachate in a sequence batch activated sludge system of 180 L. The ASBR, inoculated with a granular UASB sludge from a poultry wastewater treatment, was inefficient and presented sludge segregation and sedimentation problems. The ASBBR, inoculated using the sludge from the bottom of a landfill leachate reservoir, at the final of acclimation, presented efficiency over 70%, in terms of COD removal, utilizing landfill leachate without water dilution, with an inlet COD at the range of 11,000 mg/L, a TVA/COD ratio of approximately 0.6 and reaction time equal to 7 days. It was realized that the landfill leachate anaerobic biodegradability has a directly relationship to the TVA/COD ratio, and for TVA/COD Total ratio lower than 0.25, the biodegradability is low, for ratios between 0.25 and 0.40 is medium, and up to 0.40 may be considered high. It was also observed that \'NH IND.4\' POT.+\' concentrations at the range of 4,500 mg N/L has no significant interference in the anaerobic treatment, since the biomass has properly acclimated. At the temporal profiles of concentration performed in the ASBBR, it was adjusted a first order model for the substrate consumption, in terms of COD Total, obtaining K1 values ranging between 3.18 x \'10 POT.-5\' and 5.82 x \'10 POT.-5\' /(d.mgSTV/L). The post-treatment of the ASBBR effluents was evaluated in a sequence batch activated sludge system, which has obtained maximum efficiencies at the range of 30% in terms of COD removal, with an inlet COD at the range of 5,000 mg/L. As regards of the continuous up flow anaerobic biofilter, it has obtained efficiencies superiors to 70% when fed by a mixing of recovery landfill leachate and acidified ethanol, with an inlet COD at the range of 20,000 mg/L.

Page generated in 0.0415 seconds