• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 18
  • 3
  • 1
  • Tagged with
  • 93
  • 93
  • 93
  • 34
  • 16
  • 12
  • 11
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Contrôle de qualité dosimétrique des systèmes de planification des traitements par radiothérapie externe à l'aide d'Objets-Tests Numériques calculés par simulations Monte-Carlo PENELOPE

Ben Hdech, Yassine 19 December 2011 (has links) (PDF)
Contrôle de qualité dosimétrique des systèmes de planification des traitements par radiothérapie externe à l'aide d'Objets-Tests Numériques calculés par simulations Monte-Carlo PENELOPE En raison des besoins de précision et de l'importance des risques associés, les traitements anticancéreux par radiothérapie externe sont simulés sur des Systèmes de Planification des Traitements ou TPS avant d'être réalisés, afin de s'assurer que la prescription médicale est respectée tant du point de vue de l'irradiation des volumes cibles que de la protection des tissus sains. Ainsi les TPS calculent des distributions de dose prévisionnelles dans le patient et les temps de traitement par faisceau qui seront nécessaires pour délivrer la dose prescrite. Le TPS occupe une position clé dans le processus décisionnel des traitements par radiothérapie. Il est donc impératif qu'il fasse l'objet d'un contrôle approfondi des ses performances (contrôle de qualité ou CQ) et notamment de ses capacités à calculer avec précision les distributions de dose dans les patients pour l'ensemble des situations cliniques qu'il est possible de rencontrer. Les méthodes " traditionnelles " recommandées pour le CQ dosimétrique des algorithmes de calcul de dose implémentés dans les TPS s'appuient sur des comparaisons entre des distributions de dose calculées par le TPS et des distributions de dose mesurées sous l'appareil de traitement dans des Objets-Tests Physiques (OTP). Dans ce travail de thèse nous proposons de substituer aux mesures de dose de référence réalisées dans des OTP des calculs de distribution de dose dans des Objets-Tests Numériques, calculs réalisés grâce au code Monte-Carlo PENELOPE. L'avantage de cette méthode est de pouvoir d'une part, simuler des conditions proches de la clinique, conditions très souvent inaccessibles par la mesure du fait de leur complexité, et d'autre part, de pouvoir automatiser le processus de CQ du fait de la nature d'emblée numérique des données de référence. Enfin une telle méthode permet de réaliser un CQ du TPS extrêmement complet sans monopoliser les appareils de traitement prioritairement utilisés pour traiter les patients. Cette nouvelle méthode de CQ a été testée avec succès sur le TPS Eclipse de la société Varian Medical Systems.
12

Imagerie endoscopique de réflectance diffuse pour le diagnostic des pré-cancers et cancers précoces de la vessie : instrumentation, modélisation et validation expérimentale

Kalyagina, Nina 30 March 2012 (has links) (PDF)
L'objectif de cette thèse est d'évaluer les performances d'une méthode d'imagerie optique non-invasive pour la détection de précancers et cancers précoces de la vessie, à l'aide d'une analyse de lumière laser rétro-diffusée. L'analyse de la distribution spatiale de la lumière à la surface de fantômes multi-couches imitant l'épithelium de vessie avec différentes propriétés d'absorption et de diffusion nous a permis de montrer les modifications de ces propriétés optiques entraînent des changements de la taille de la surface du spot de lumière rétro-diffusée, mesurables par une caméra vidéo. La méthode développée est également sensible à l'accumulation d'un photosensibilisateur et est applicable aussi bien pour des études en réflectance diffuse qu'en fluorescence induite. Les paramètres optiques des fantômes synthétiques tri-couches imitant différents états des épithéliums de vessie ont été calculés à partir de la théorie des ondes électromagnétiques appliquée aux diffuseurs sphériques sans et avec une couche. Ces paramètres ont servi comme entrées aux simulations de Monte Carlo qui ont permis d'obtenir les matrices des distributions d'intensité de réflectance diffuse. Notre étude démontre que les mesures en imagerie de réflectance diffuse non-polarisée permettent de fournir des informations utiles au diagnostic tissulaire.
13

Contrôle stochastique et méthodes numériques en finance mathématique

Elie, Romuald 11 December 2006 (has links) (PDF)
Cette thèse présente trois sujets de recherche indépendants appartenant au domaine des méthodes numériques et du contrôle stochastique avec des applications en mathématiques financières.<br /><br />Nous présentons dans la première partie une méthode non-paramétrique d'estimation des sensibilités des prix d'options. A l'aide d'une perturbation aléatoire du paramètre d'intérêt, nous représentons ces sensibilités sous forme d'espérance conditionnelle, que nous estimons à l'aide de simulations Monte Carlo et de régression par noyaux. Par des arguments d'intégration par parties, nous proposons plusieurs estimateurs à noyaux de ces sensibilités, qui ne nécessitent pas la connaissance de la densité du sous-jacent, et nous obtenons leurs propriétés asymptotiques. Lorsque la fonction payoff est irrégulière, ils convergent plus vite que les estimateurs par différences finies, ce que l'on vérifie numériquement.<br /><br />La deuxième partie s'intéresse à la résolution numérique de systèmes découplés d'équations différentielles stochastiques progressives rétrogrades. Pour des coefficients Lipschitz, nous proposons un schéma de discrétisation qui converge plus vite que $n^{-1/2+e}$, pour tout $e>0$, lorsque le pas de temps $1/n$ tends vers $0$, et sous des hypothèses plus fortes de régularité, le schéma atteint la vitesse de convergence paramétrique. L'erreur statistique de l'algorithme dûe a l'approximation non-paramétrique d'espérances conditionnelles est également controlée et nous présentons des exemples de résolution numérique de systèmes couplés d'EDP semi-linéaires.<br /><br />Enfin, la dernière partie de cette thèse étudie le comportement d'un gestionnaire de fond, maximisant l'utilité intertemporelle de sa consommation, sous la contrainte que la valeur de son portefeuille ne descende pas en dessous d'une fraction fixée de son maximum courant. Nous considérons une classe générale de fonctions d'utilité, et un marché financier composé d'un actif risqué de dynamique black-Scholes. Lorsque le gestionnaire se fixe un horizon de temps infini, nous obtenons sous forme explicite sa stratégie optimale d'investissement et de consommation, ainsi que la fonction valeur du problème. En horizon fini, nous caractérisons la fonction valeur comme unique solution de viscosité de l'équation d'Hamilton-Jacobi-Bellman correspondante.
14

Evaluation de la dose déposée par des faisceaux d'électrons en radiothérapie dans des fantômes voxelisés en utilisant la plateforme de simulation Monte Carlo GATE fondée sur GEANT4 dans un environnement de grille

Perrot, Yann 08 December 2011 (has links) (PDF)
La planification de traitement en radiothérapie nécessite un calcul précis de la dose délivrée au patient. La méthode la plus fiable pour y parvenir est la simulation du transport des particules par technique Monte Carlo. Cette thèse constitue la première étude concernant la validation de la plateforme de simulation Monte Carlo GATE (GEANT4 Application for Tomographic Emission), basée sur les librairies de GEANT4 (GEometry ANd Tracking), pour le calcul de la dose absorbée déposée par des faisceaux d'électrons. L'objectif de cette thèse est de montrer que GATE/GEANT4 est capable d'atteindre le niveau d'exigences requis pour le calcul de la dose absorbée lors d'une planification de traitement, dans des situations où les algorithmes analytiques, actuellement utilisés dans les services de radiothérapie, n'atteignent pas un niveau de précision satisfaisant. L'enjeu est de prouver que GATE/GEANT4 est adapté pour la planification de traitement utilisant des électrons et capable de rivaliser avec d'autres codes Monte Carlo reconnus. Cet enjeu a été démontré par la simulation avec GATE/GEANT4 de faisceaux et des sources d'électrons réalistes utilisées en radiothérapie externe ou en radiothérapie moléculaire et la production de distributions de dose absorbée en accord avec les mesures expérimentales et avec d'autres codes Monte Carlo de référence pour la physique médicale. Par ailleurs, des recommandations quant à l'utilisation des paramètres de simulation à fixer, assurant un calcul de la distribution de dose absorbée satisfaisant les spécifications en radiothérapie, sont proposées.
15

Evaluation de la dose déposée par des faisceaux d'électrons en radiothérapie dans des fantômes voxelisés en utilisant la plateforme de simulation Monte Carlo GATE fondée sur GEANT4 dans un environnement de grille / Evaluation of the dose deposited by electron beams in radiotherapy in voxelized phantoms using the Monte Carlo GATE simulation platform based on GEANT4 in a grid environment

Perrot, Yann 08 December 2011 (has links)
La planification de traitement en radiothérapie nécessite un calcul précis de la dose délivrée au patient. La méthode la plus fiable pour y parvenir est la simulation du transport des particules par technique Monte Carlo. Cette thèse constitue la première étude concernant la validation de la plateforme de simulation Monte Carlo GATE (GEANT4 Application for Tomographic Emission), basée sur les librairies de GEANT4 (GEometry ANd Tracking), pour le calcul de la dose absorbée déposée par des faisceaux d’électrons. L’objectif de cette thèse est de montrer que GATE/GEANT4 est capable d’atteindre le niveau d’exigences requis pour le calcul de la dose absorbée lors d’une planification de traitement, dans des situations où les algorithmes analytiques, actuellement utilisés dans les services de radiothérapie, n’atteignent pas un niveau de précision satisfaisant. L’enjeu est de prouver que GATE/GEANT4 est adapté pour la planification de traitement utilisant des électrons et capable de rivaliser avec d’autres codes Monte Carlo reconnus. Cet enjeu a été démontré par la simulation avec GATE/GEANT4 de faisceaux et des sources d’électrons réalistes utilisées en radiothérapie externe ou en radiothérapie moléculaire et la production de distributions de dose absorbée en accord avec les mesures expérimentales et avec d’autres codes Monte Carlo de référence pour la physique médicale. Par ailleurs, des recommandations quant à l’utilisation des paramètres de simulation à fixer, assurant un calcul de la distribution de dose absorbée satisfaisant les spécifications en radiothérapie, sont proposées. / Radiation therapy treatment planning requires accurate determination of absorbed dose in the patient. Monte Carlo simulation is the most accurate method for solving the transport problem of particles in matter. This thesis is the first study dealing with the validation of the Monte Carlo simulation plateform GATE (GEANT4 Application for Tomographic Emission), based on GEANT4 (GEometry And Tracking) libraries, for the computation of absorbed dose deposited by electron beams. This thesis aims at demonstrating that GATE/GEANT4 calculations are able to reach treatment planning requirements in situations where analatycal algorithms are not satisfactory. The goal is to prove that GATE/GEANT4 is useful for treatment planning using electrons and competes with well validated Monte Carlo codes. This is demonstrated by the simulations with GATE/GEANT4 of realistic electron beams and electron sources used for external radiation therapy or targeted radiation therapy. The computed absorbed dose distributions are in agreement with experimental measurements and/or calculations from other Monte Carlo codes. Furthermore, guidelines are proposed to fix the physics parameters of the GATE/GEANT4 simulations in order to ensure the accuracy of absorbed dose calculations according to radiation therapy requirements.
16

Etude et conception d’un détecteur 2D transparent permettant le suivi en temps réel de l'administration des traitements rcmi / Study and conception of a 2D transparent detector to monitor the beam in real time for modulated radiotherapy treatments

Fonteille, Isabelle 27 May 2016 (has links)
La Radiothérapie Conformationnelle avec Modulation d'Intensité (RCMI), aussi dénommée IMRT, est une technique avancée de radiothérapie de haute précision qui repose sur l'utilisation d'un collimateur multi-lames, placé en sortie de l'accélérateur, dont les lames vont se déplacer pendant la séance d'irradiation afin de produire un faisceau d'intensité modulée, adaptée à la forme des structures anatomiques du patient. Un tel dispositif permet d'obtenir une répartition de dose homogène dans le volume cible et d'épargner au mieux les tissus sains environnants1, ouvrant la voie à l'escalade de dose et donc à l'amélioration des résultats thérapeutiques. Néanmoins, la mise en œuvre d'une telle technique nécessite la réalisation d'un contrôle du système de délivrance de la dose de manière à s'assurer que la fluence délivrée par l'appareil de traitement est bien conforme à la fluence attendue. / Intensity Modulated Radiotherapy (IMRT) is a high-precision radiotherapy technique based on the use of a multi-leaf collimator, placed at the output of the accelerator. The modulation is adapted to the patient's anatomical structures and obtained by leaves movement during the beam administration. To ensure that the delivered fluence is consistent with the expected one, a control is necessary. In clinical routine, this control isn't achieved on the patient, but on a phantom, before the beginning of the treatment New emerging solutions make possible an online control, done during the treatment of the patient. They can be divided into three classes: those which use data acquired by the accelerator, those which exploit the portal imager and those which use a dedicated detector placed at the exit of the head of the accelerator, upstream of the patient. The thesis work presented here relate to the development of a detector of this third class, Tradera (Transparent Detector for Radiotherapy). The choice was made to use a segmented plane ionization chamber.The first phase of the project was to design the detector thanks to studies made by Monte Carlo simulations. For this it was necessary to model the photon beam. The choice of a point source of photons, quick to set up, has been retained. The characteristics of the particles at the detector input obtained with our model were compared with those obtained with a more complex model: a phase space obtained from the database of the IAEA. Once the model validated, Geant4 code was used to size the various elements of our detector. A innovative geometry has been proposed. It consists in introducing material in the sensitive volume of the detector to limit the lateral travel of the electrons from the interaction of photons, and thus improve the spatial resolution of the detector. In practice, a checkerboard with plastic pads is introduced in the sensitive volume. The benefit of this solution has been shown by simulations.The second phase was to assess a prototype in a clinical beam with radiation equipment and test the performance of various associated acquisition electronics. For a long time, reading was made at the output of a single channel at a time. First, a picoammeter was used to measure the average output current. Then the ionization current has been studied at the time scale of a pulse of the beam, allowing the development of a charge preamplifier dedicated to our application. This charge preamplifier permit to know, for a single beam pulse, the electrical charge measured by one channel of the prototype with a uncertainty of 5%, and thus makes it possible to study the evolution of the charge pulse as a function of irradiation time. Once the choice of this readout electronics was validated, the charge preamplifier was realized in small series : the acquisition in multi-channels on an area of ​​3 cm square was possible. The first beam images could then be obtained for static and dynamic beam.
17

Etude expérimentale et modélisation Monte Carlo des grandeurs opérationnelles en métrologie des rayonnements ionisants : application à la dosimétrie neutrons par radiophotoluminescence / Experimental study and Monte Carlo modeling of operational quantities in metrology of ionizing radiation : application to neutrons dosimetry by radiophotoluminescence

Salem, Youbba Ould 09 September 2014 (has links)
Nous mettons au point un dosimètre passif capable de détecter les neutrons rapides et thermiques, destiné à la fois à la dosimétrie d'ambiance et personnelle. Ce dosimètre détecte les neutrons au moyen de convertisseurs appropriés (polyéthylène et cadmium). Cette étude s'est appuyée sur des simulations Monte Carlo, qui ont aidé à la conception géométrique du dosimètre et au choix des matériaux. La caractérisation expérimentale du dosimètre montre que les réponses à ces neutrons en termes de H*(10) et Hp(10) sont linéaires, avec des seuils de détection de 2 mSv pour les neutrons rapides et de 0, 19 mSv pour les neutrons thermiques. Les dépendances angulaires sont satisfaisantes selon les recommandations de la norme ISO 21909. Un facteur de calibration de (9,5 +- 0,5)x10 puissance -2 mSv.cm2/signal RPL a été obtenu pour les neutrons rapides de la source calibrée de 241Am-Be de l'IPHC. Ce facteur est de (9,7 +- 0,3)x10 puissance-3 mSv.cm2/signal RPL pour les neutrons thermalisés. / We characterize a passive dosimeter capable of measuring both fast and thermal neutrons for ambiant and persona! dosimetry. These neutrons can be detected in a mixed neutron-gamma field with appropriate converters (polyethylene for fast neutrons, cadmium for thermal neutrons). Monte Carlo simulations with MCNPX helped with the geometrical conception of the dosimeter and the choice of materials. The responses of the RPL dosimeter to these neutrons are linear in H*(1 O) and Hp(10) with detection limits of 2 mSv for fast neutrons and 0.19 mSv for thermal neutrons. The angular dependencies are satisfactory according to the ISO 21909 norm. A calibration factor of (9.5 +- 0.5)x10 exponent -2 mSv.cm2/RPL signal is obtained to the fast neutrons of the IPHC's 241 Am-Be calibrator. This factor is (9.7 +- 0.3)x10 exponent -3 mSv.cm2/RPL signal for the thermalized neutrons.
18

Développement d'un dosimètre diamant pour une mesure de la dose absorbée dans les mini-faisceaux utilisés en radiothérapie stéréotaxique. / Development of a diamond dosimeter for measuring the absorbed dose in small beams used in stereotactic radiotherapy

Marsolat, Fanny 10 January 2014 (has links)
La radiothérapie stéréotaxique est une technique de pointe relativement récente utilisée pour le traitement de tumeurs bénignes ou malignes de petites dimensions employant des mini-faisceaux. L'efficacité clinique de cette technique est prouvée et n'est pas remise en cause, cependant il n'existe pas actuellement de dosimètre véritablement approprié permettant de caractériser ces faisceaux de petites dimensions par des mesures précises de dose absolue et relative. Le problème du manque d'équilibre électronique latéral rencontré en mini-faisceaux entraîne principalement les contraintes suivantes pour le dosimètre : équivalence-eau et petit volume de détection. Les caractéristiques du diamant (faible numéro atomique Z=6, densité élevée d'atomes) en font un candidat idéal. Au cours de cette thèse, nous avons développé un prototype de dosimètre pour mini-faisceaux à partir de diamant monocristallin synthétique CVD. Les échantillons ont été caractérisés optiquement par différentes techniques et leurs propriétés de détection ont été étudiées sous rayonnement X et sous particules ?. Une série de premiers prototypes a été développée et testée sur plusieurs machines de stéréotaxie. Une étape d'optimisation de ces premiers dosimètres diamant a ensuite été réalisée notamment par l'utilisation de simulations Monte Carlo. L'optimisation des différents paramètres entrant en jeu dans la réponse du dosimètre en mini-faisceaux a permis d'aboutir à un prototype final de dosimètre diamant. Ce prototype répond au cahier des charges rédigé par les physiciens médicaux des centres hospitaliers, aussi bien en champs standards qu'en mini-faisceaux. / Stereotactic radiotherapy is a relatively recent technique used for the treatment of small benign and malignant tumors with small radiation beams. The clinical efficiency of this technique has been proved. However, the measurement of absolute and relative dose in small beams is not possible currently due to the lack of suited detectors for these measurements. In small beam dosimetry, the detector has to be as close as possible to tissue equivalence and exhibit a small detection volume due to the lack of lateral electronic equilibrium. Characteristics of diamond (water equivalent material Z=6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. In this thesis, we developed a dosimeter prototype for small beams, based on CVD synthetic single crystal diamond. The diamond samples were characterized optically and their detection properties were investigated under X-rays and alpha-particles. First diamond dosimeter prototypes were tested with small beams produced by several stereotactic machines. Studies using Monte Carlo simulations were performed in order to optimize the parameters involved in the detector response in small beams. This leaded to a final diamond dosimeter prototype that respects all radiotherapy centers requirements, in both standard and small beams.
19

Modélisation des propriétés magnéto-électriques d'oxydes de métaux de transition anisotropes. / Modeling of the magnetoelectric properties of anisotropic transition metal oxides

Al Baalbaky, Ahmed 21 December 2017 (has links)
Les oxydes de métaux de transition sont largement utilisés en raison de leurs propriétés fondamentales intéressantes et de leurs applications importantes. En particulier, CuCrO2 est d’un intérêt particulier parce qu’il possède un état multiferroïque en absence de champ magnétique. Dans cette thèse, nous modélisons les propriétés magnéto-électriques de CuCrO2 par simulations Monte Carlo basées sur des paramètres magnétiques déterminés par calculs ab initio. Nous étudions également l’effet du dopage du Ga sur les propriétés magnéto-électriques du composé CuCr1-xGaxO2 (0 ≤ x ≤ 0:3). Nos résultats sontqualitativement en accord avec les observations expérimentales. / Transition metal oxides are widely used due to their interesting fundamental properties and important applications. In particular, CuCrO2 is of special interest because it enters the multiferroic state in zero magnetic fields. In this thesis we model the magnetoelectric properties of CuCrO2 using Monte Carlo simulations with the help of ab initio calculations.We also investigate the effect of Ga doping on the magnetoelectric properties of CuCr1-xGaxO2 (0 ≤ x ≤ 0:3). Our results are well comparable to the experimental observations.
20

Spatial fractionation of the dose in charged particle therapy / Fractionnement spatial de la dose en radiothérapie par particules chargées

Peucelle, Cécile 04 November 2016 (has links)
Malgré de récentes avancées, les traitements par radiothérapie (RT) demeurent insatisfaisants : la tolérance des tissus sains aux rayonnements limite la délivrance de fortes doses (potentiellement curatives) à la tumeur. Pour remédier à ce problème, de nouvelles approches basées sur des modes de dépôt de dose innovants sont aujourd’hui à l’étude. Parmi ces approches, la technique synchrotron “Minibeam Radiation Therapy” (MBRT) a démontré sa capacité à élever la résistance des tissus sains aux rayonnements, ainsi qu’à induire un important retard de croissance tumorale. La MBRT combine des faisceaux submillimétriques à un fractionnement spatial de la dose. Dans ce contexte, l’alliance de la balistique plus avantageuse des particules chargées (et leur sélectivité biologique) à la préservation des tissus sains observée en MBRT permettrait de préserver d’avantage les tissus sains. Cette stratégie innovante a été explorée durant ce travail de thèse. Deux voies ont notamment été étudiées: la MBRT par faisceaux de protons (pMBRT), et d’ions très lourds. Premièrement, la preuve de concept expérimentale de la pMBRT a été réalisée dans un centre clinique (Institut Curie, Centre de Protonthérapie d’Orsay). De plus, l'évaluation de potentielles optimisations de la pMBRT, à la fois en terme de configuration d’irradiation et de génération des minifaisceaux, a été menée dans une étude Monte Carlo (MC). Dans la seconde partie de ce travail, un nouvel usage potentiel des ions très lourds (néon et plus lourds) en radiothérapie a été évalué dans une étude MC. Les combiner à un fractionnement spatial permettrait de tirer profit de leur efficacité dans le traitement de tumeurs radiorésistantes (hypoxiques), un des principaux défis de la RT, tout en minimisant leurs effets secondaires. Les résultats obtenus au terme de ce travail sont favorables à une exploration approfondie de ces deux approches innovantes. Les données dosimétriques compilées dans ce manuscrit serviront à guider prochaines les expérimentations biologiques. / Despite recent breakthroughs, radiotherapy (RT) treatments remain unsatisfactory : the tolerance of normal tissues to radiations still limits the possibility of delivering high (potentially curative) doses in the tumour. To overcome these difficulties, new RT approaches using distinct dose delivery methods are being explored. Among them, the synchrotron minibeam radiation therapy (MBRT) technique has been shown to lead to a remarkable normal tissue resistance to very high doses, and a significant tumour growth delay. MBRT allies sub-millimetric beams to a spatial fractionation of the dose. The combination of the more selective energy deposition of charged particles (and their biological selectivity) to the well-established normal tissue sparing of MBRT could lead to a further gain in normal tissue sparing. This innovative strategy was explored in this Ph.D. thesis. In particular, two new avenues were studied: proton MBRT (pMBRT) and very heavy ion MBRT. First, the experimental proof of concept of pMBRT was performed at a clinical facility (Institut Curie, Orsay, France). In addition, pMBRT setup and minibeam generation were optimised by means of Monte Carlo (MC) simulations. In the second part of this work, a potential renewed use of very heavy ions (neon and heavier) for therapy was evaluated in a MC study. Combining such ions to a spatial fractionation could allow profiting from their high efficiency in the treatment of hypoxic radioresistant tumours, one of the main challenges in RT, while reducing at maximum their side effects. The promising results obtained in this thesis support further explorations of these two novel avenues. The dosimetry knowledge acquired will serve to guide the biological experiments.

Page generated in 0.1531 seconds