• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 2
  • 1
  • Tagged with
  • 27
  • 14
  • 14
  • 11
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da função ventricular esquerda pelo dP/dt não-invasivo em cães com doença valvar crônica mitral / Left ventricle function assessment by non-invasive dP/dt in dogs with chronic mitral valve disease

Duarte, Caio Nogueira 14 April 2015 (has links)
O +dP/dt e o dP/dt são considerados índices ecocardiográficos de avaliação da função sistólica e diastólica, respectivamente, menos influenciados pela pré e pós-carga do que os índices calculados na fase de ejeção. O objetivo desse estudo foi determinar se o dP/dt não-invasivo se correlaciona com os índices ecocardiográficos sistólicos e diastólicos e se pode ser usado para identificar animais com e sem remodelamento, aqueles com e sem ICC e avaliar a gravidade da DVCM. Esta pesquisa constituiu um estudo clínico observacional prospectivo transversal, realizada em cães com DVCM. Comparou-se o +dP/dt e o dP/dt entre grupos divididos quanto à presença de remodelamento e presença ou não de ICC; para a comparação do dP/dt em relação à função diastólica do VE, os cães foram distribuídos de acordo com o padrão diastólico. Os cães foram submetidos ao exame ecodopplercardiográfico para mensuração do +dP/dt, -dP/dt e dos demais índices ecocardiográficos. Foram inclusos ao todo 57 cães com DVCM, em estágios B1 (n=13), B2 (n=18) e C+D (n=26). Comparando-se o +dP/dt nos três grupos divididos de acordo com à presença de remodelamento, com ou sem ICC, o grupo C+D (2142 mmHg/s, P25-P75 = 2023-2456) apresentou +dP/dt significativamente mais baixo que o grupo B1 (2865 mmHg/s, P25-P75 = 2383-3308) e B2 (2721 mmHg/s, P25-P75 = 2241-3186) (P = 0,0023). O mesmo foi observado para o dP/dt, quando comparado o grupo C+D ao grupo B1 (968,5 mmHg/s ± 266,8 e 1198 mmHg/s ± 165,7; P= 0,0115). Quando o dP/dt foi comparado entre os grupos com ICC e sem ICC, o grupo com ICC apresentou valores menores tanto do +dP/dt (2142 mmHg/s, P25-P75 = 2023-2456; 2858 mmHg/s, P25-P75 = 2299-3241; P = 0,0007) como do dP/dt (968,5 ± 266,8 mmHg/s e 1155 mmHg/s ± 199,0; P = 0,0041). Quanto à função diastólica, o grupo com padrão restritivo (769,7 mmHg/s ± 124,1) apresentou valores menores do -dP/dt quando comparados aos grupos sem disfunção diastólica (1132 mmHg ± 204,0), alteração de relaxamento (1229 mmHg ±186,9) e padrão pseudonormal (1107 mmHg ±223,4) (P< 0,0001). Utilizando-se +dP/dt<1800 mmHg/s como ponto de corte, houve duas vezes mais chance do cão com DVCM ter ICC do que não ter. Considerando-se como ponto de corte um -dP/dt<800mmHg/s, a chance de ter ICC é oito vezes maior do que não ter e a chance de ter padrão diastólico restritivo é oito vezes maior do que não ter. Conclui-se que o +dP/dt e o dP/dt não-invasivos podem contribuir, respectivamente, para a avaliação da função sistólica e diastólica. / Noninvasive +dP/dt and dP/dt derived from mitral regurgitant jet are considered echocardiographic indexes for assessment of systolic and diastolic function respectively, that have less preload and afterload dependence than the ejection phase indexes. This study aimed to determine whether non-invasive dP/dt correlates with other systolic and diastolic echocardiographic indexes, and if they can be used to identify dogs with and without remodeling, with or without congestive heart failure (CHF) and for evaluation of chronic mitral valve disease (CMVD) severity. An observational prospective cross-sectional clinical study was undertaken including dogs with CMVD. Dogs were distributed in groups regarding the presence of remodeling and heart failure,to evaluate +dP/dt and dP/dt, and distributed according the diastolic pattern to compare dP/dt regarding diastolic function. Echocardiographic exam was obtained for conventional indexes and to measure +dP/dt and -dP/dt. Fifty seven dogs diagnosed with CMVD and classified according to the stages [B1 (n=13), B2 (n=18), C+D (n=26)] were included. In the comparison among the three groups regarding the presence of remodeling and CHF, group C+D (2142 mmHg/s, P25-P75 = 2023-2456) had +dP/dt significantly lower than B1 (2865 mmHg/s, P25-P75 = 2383-3308) and B2 (2721 mmHg/s, P25-P75 = 2241-3186) (P = 0.0023). Group C+D also had lower dP/dt, compared to B1 (968.5 mmHg/s ± 266.8 and 1198 mmHg/s ± 165.7; P= 0.0115). Group of dogs with CHF compared to those without CHF, showed lower +dP/dt (2142 mmHg/s, P25-P75 = 2023-2456; 2858 mmHg/s, P25-P75 = 2299-3241; P = 0.0007) as well as dP/dt (968.5 ± 266.8 mmHg/s e 1155 mmHg/s ± 199.0; P=0.0041). Regarding diastolic function, -dP/dt was lower for the restrictive pattern group (769.7 mmHg/s ± 124.1) compared to those without diastolic disfunction, (1132 mmHg ± 204.0), relaxation abnormality (1229 mmHg ±186.9) and pseudonormal pattern (1107 mmHg ±223.4) (P< 0.0001). Considering +dP/dt&lt1800 mmHg/s as cutoff value, there is twice the chance for the dog with CMVD to have CHF than not to have. With a -dP/dt<800mmHg/s as a cut off value, the chance of having CHF is eigth times higher than not having it. It is concluded that non-invasive doppler derived +dP/dt and dP/dt may contribute respectively, for systolic and diastolic assessment of dogs with CMVD.
12

Avaliação ecocardiográfica de coelhos submetidos à infusão contínua de lidocaína sedados com midazolam /

Marques, Ana Elisa Gregui Watanabe January 2019 (has links)
Orientador: Paulo Sergio Patto dos Santos / Resumo: A lidocaína é um fármaco versátil muito utilizado na rotina clínica. No entanto, há poucos estudos que avaliam os seus efeitos sobre o coração. Para esta finalidade, a ecocardiografia transtorácica é uma ferramenta que possibilitava a avaliação das funções sistólica e diastólica em tempo real. Como este estudo, objetivou-se avaliar os efeitos da infusão contínua de lidocaína sobre as funções sistólica e diastólica do ventrículo esquerdo de coelhos hígidos sedados com midazolam. Para tanto, foram utilizados dez coelhos da raça Nova Zelândia, quatro machos e seis fêmeas, com idade de nove meses, pesando 3,2 ± 0,3 kg, sendo todos os animais sedados com midazolam na dose de 1 mg/kg pela via intramuscular e submetidos a dois tratamentos experimentais (controle e lidocaína) com intervalo mínimo de sete dias entre os tratamentos. No tratamento controle (TC) administrou-se solução de cloreto de sódio a 0,9% (0,05 mL/kg) em bolus seguida de infusão contínua na taxa de 5 mL/hora; no tratamento lidocaína (TL) administrou-se primeiramente um bolus de lidocaína a 2% sem vasoconstritor na dose de 1 mg/kg seguido de infusão contínua na taxa de 50 µg/kg/minuto, sendo mantidos os mesmos volumes administrados para ambos os tratamentos. As principais variáveis analisadas foram: frequência cardíaca (FC), pressão arterial média (PAM), índice de resistência vascular periférica (IRVP), índice cardíaco Doppler (ICD), fração de encurtamento (FEC), fração de ejeção (FEJ), velocidade da onda S′ e relaç... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Lidocaine is a versatile drug widely used in clinical practice. However, there are few studies that evaluate its effects on the heart. For this purpose, transthoracic echocardiography is a tool that allows an evaluation of the systematic and diastolic units in real time. The aim of the study was evaluate the effects of continuous rate infusion of lidocaine on systolic and diastolic functions of the left ventricle of healthy rabbits sedated with midazolam. Ten New Zealand rabbits, four males and six females, aged nine months, weighing 3.2 ± 0.3 kg were sedated with midazolam at the dose of 1 mg/kg intramuscularly and submitted to two experimental treatments (control and lidocaine) with a minimum interval of seven days. In the control treatment (CT), 0.9% sodium chloride solution (0.05 mL.kg-1 ) was administered in bolus followed by continuous infusion at a rate of 5 mL.hour-1 ; a 2% lidocaine bolus without vasoconstrictor at the dose of 1 mg.kg-1 followed by continuous infusion at the rate of 50 μg.kg-1 .minute-1 was first given in lidocaine treatment (LT). The main variables analyzed were: heart rate (HR), mean arterial pressure (MAP), peripheral vascular resistance index (PVR), Doppler cardiac index (DCI), shortening fraction (FEC), ejection fraction (EFJ), velocity of the wave S 'and relation E'/A'. All parameters were evaluated before the onset of the bolus (MB) and 20, 40 and 60 minutes after the start of continuous rate infusion (M20, M40 and M60). The studied variables ... (Complete abstract click electronic access below) / Mestre
13

Avaliação da função ventricular esquerda pelo dP/dt não-invasivo em cães com doença valvar crônica mitral / Left ventricle function assessment by non-invasive dP/dt in dogs with chronic mitral valve disease

Caio Nogueira Duarte 14 April 2015 (has links)
O +dP/dt e o dP/dt são considerados índices ecocardiográficos de avaliação da função sistólica e diastólica, respectivamente, menos influenciados pela pré e pós-carga do que os índices calculados na fase de ejeção. O objetivo desse estudo foi determinar se o dP/dt não-invasivo se correlaciona com os índices ecocardiográficos sistólicos e diastólicos e se pode ser usado para identificar animais com e sem remodelamento, aqueles com e sem ICC e avaliar a gravidade da DVCM. Esta pesquisa constituiu um estudo clínico observacional prospectivo transversal, realizada em cães com DVCM. Comparou-se o +dP/dt e o dP/dt entre grupos divididos quanto à presença de remodelamento e presença ou não de ICC; para a comparação do dP/dt em relação à função diastólica do VE, os cães foram distribuídos de acordo com o padrão diastólico. Os cães foram submetidos ao exame ecodopplercardiográfico para mensuração do +dP/dt, -dP/dt e dos demais índices ecocardiográficos. Foram inclusos ao todo 57 cães com DVCM, em estágios B1 (n=13), B2 (n=18) e C+D (n=26). Comparando-se o +dP/dt nos três grupos divididos de acordo com à presença de remodelamento, com ou sem ICC, o grupo C+D (2142 mmHg/s, P25-P75 = 2023-2456) apresentou +dP/dt significativamente mais baixo que o grupo B1 (2865 mmHg/s, P25-P75 = 2383-3308) e B2 (2721 mmHg/s, P25-P75 = 2241-3186) (P = 0,0023). O mesmo foi observado para o dP/dt, quando comparado o grupo C+D ao grupo B1 (968,5 mmHg/s ± 266,8 e 1198 mmHg/s ± 165,7; P= 0,0115). Quando o dP/dt foi comparado entre os grupos com ICC e sem ICC, o grupo com ICC apresentou valores menores tanto do +dP/dt (2142 mmHg/s, P25-P75 = 2023-2456; 2858 mmHg/s, P25-P75 = 2299-3241; P = 0,0007) como do dP/dt (968,5 ± 266,8 mmHg/s e 1155 mmHg/s ± 199,0; P = 0,0041). Quanto à função diastólica, o grupo com padrão restritivo (769,7 mmHg/s ± 124,1) apresentou valores menores do -dP/dt quando comparados aos grupos sem disfunção diastólica (1132 mmHg ± 204,0), alteração de relaxamento (1229 mmHg ±186,9) e padrão pseudonormal (1107 mmHg ±223,4) (P< 0,0001). Utilizando-se +dP/dt<1800 mmHg/s como ponto de corte, houve duas vezes mais chance do cão com DVCM ter ICC do que não ter. Considerando-se como ponto de corte um -dP/dt<800mmHg/s, a chance de ter ICC é oito vezes maior do que não ter e a chance de ter padrão diastólico restritivo é oito vezes maior do que não ter. Conclui-se que o +dP/dt e o dP/dt não-invasivos podem contribuir, respectivamente, para a avaliação da função sistólica e diastólica. / Noninvasive +dP/dt and dP/dt derived from mitral regurgitant jet are considered echocardiographic indexes for assessment of systolic and diastolic function respectively, that have less preload and afterload dependence than the ejection phase indexes. This study aimed to determine whether non-invasive dP/dt correlates with other systolic and diastolic echocardiographic indexes, and if they can be used to identify dogs with and without remodeling, with or without congestive heart failure (CHF) and for evaluation of chronic mitral valve disease (CMVD) severity. An observational prospective cross-sectional clinical study was undertaken including dogs with CMVD. Dogs were distributed in groups regarding the presence of remodeling and heart failure,to evaluate +dP/dt and dP/dt, and distributed according the diastolic pattern to compare dP/dt regarding diastolic function. Echocardiographic exam was obtained for conventional indexes and to measure +dP/dt and -dP/dt. Fifty seven dogs diagnosed with CMVD and classified according to the stages [B1 (n=13), B2 (n=18), C+D (n=26)] were included. In the comparison among the three groups regarding the presence of remodeling and CHF, group C+D (2142 mmHg/s, P25-P75 = 2023-2456) had +dP/dt significantly lower than B1 (2865 mmHg/s, P25-P75 = 2383-3308) and B2 (2721 mmHg/s, P25-P75 = 2241-3186) (P = 0.0023). Group C+D also had lower dP/dt, compared to B1 (968.5 mmHg/s ± 266.8 and 1198 mmHg/s ± 165.7; P= 0.0115). Group of dogs with CHF compared to those without CHF, showed lower +dP/dt (2142 mmHg/s, P25-P75 = 2023-2456; 2858 mmHg/s, P25-P75 = 2299-3241; P = 0.0007) as well as dP/dt (968.5 ± 266.8 mmHg/s e 1155 mmHg/s ± 199.0; P=0.0041). Regarding diastolic function, -dP/dt was lower for the restrictive pattern group (769.7 mmHg/s ± 124.1) compared to those without diastolic disfunction, (1132 mmHg ± 204.0), relaxation abnormality (1229 mmHg ±186.9) and pseudonormal pattern (1107 mmHg ±223.4) (P< 0.0001). Considering +dP/dt&lt1800 mmHg/s as cutoff value, there is twice the chance for the dog with CMVD to have CHF than not to have. With a -dP/dt<800mmHg/s as a cut off value, the chance of having CHF is eigth times higher than not having it. It is concluded that non-invasive doppler derived +dP/dt and dP/dt may contribute respectively, for systolic and diastolic assessment of dogs with CMVD.
14

Ecocardiografia convencional e speckle tracking bidimensional em cães saudáveis anestesiados com sevofluorano e submetidos a infusão contínua de nalbufina /

Marques, Marcel Gambin January 2020 (has links)
Orientador: Paulo Sergio Patto dos Santos / Resumo: A nalbufina é um opioide agonista-antagonista com propriedades analgésicas adequadas e poucos efeitos depressores no sistema respiratório. Sua utilização na medicina veterinária é limitada pois muitos veterinários desconhecem suas vantagens. Além disso, seus efeitos na função cardíaca são pouco estudados. Portanto, com o estudo objetivou-se avaliar os efeitos da infusão contínua de nalbufina na função sistólica e diastólica do ventrículo esquerdo em cães saudáveis anestesiados com sevofluorano. Foram utilizados dezoito cães fêmeas de diversas raças ou sem raça definida, com idade média de 2 ± 1 anos e peso médio de 9,9 ± 3,8 kg. Os cães foram aleatoriamente submetidos a dois grupos denominados: nalbufina (GN) e controle (GC), com nove animais para cada grupo. Os animais foram induzidos e mantidos sob anestesia com sevofluorano (2V%). No GN foi administrado bolus intravenoso de nalbufina (0,3 mg/kg), seguido de infusão continua (0,4 mg/kg/h). O GC recebeu solução salina (NaCl 0,9%), em volumes idênticos em bolus e infusão ao GN. As variáveis ecocardiográficas de função sistólica e diastólica e os parâmetros hemodinâmicas foram determinadas no momento basal (antes do bolus) e 20, 40, 60 e 80 minutos após o início da infusão contínua. Não houve diferença entre os grupos para os parâmetros de função sistólica e diastólica ventricular esquerda derivados da ecocardiografia convencional e speckle tracking bidimensional. Do mesmo modo, as variáveis hemodinâmicas não apresentaram dife... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Nalbuphine is an agonist-antagonist opioid with adequate analgesic properties and few depressant effects on the respiratory system. Its use in veterinary medicine is limited due to the unknown of its effects on cardiac function. The aim of this study was to assess the effects of a continuous rate infusion (CRI) of nalbuphine on left ventricular systolic and diastolic function of healthy sevoflurane-anesthetized dogs. Were used eighteen mixed-breed bitches ageging 2 ± 1 years and weighing 9.9 ± 3.8 kg. Dogs were randomly assigned to one of two groups: nalbuphine (GN, n=9); and control (GC, n=9). Anesthesia was induced and maintained with sevoflurane (2V%) followed by an intravenous (IV) bolus of nalbuphine (0.3 mg/kg) or 0.9% NaCl at equal volume, then CRI of nalbuphine (0.4 mg/kg/h) or 0.9% NaCl at equal infusion rate. Echocardiographic and hemodynamic variables were determined at baseline and 20, 40, 60 and 80 minutes following start of CRI. No differences were found between groups for left ventricular systolic and diastolic variables obtained through conventional echocardiography and two-dimensional speckle tracking. Likewise, hemodynamic variables did not differ between groups. The E′/A′ ratio significantly increased at 20 minutes compared to baseline only in GN. Nalbuphine given at a CRI does not influence left ventricular systolic and diastolic function in healthy sevoflurane-anesthetized dogs. / Doutor
15

Avaliação ecocardiográfica dos índices de função sistólica e diastólica de cães com cardiomiopatia dilatada idiopática submetidos ao tratamento com carvedilol / Echocardiographic evaluation of systolic and diastolic parameters of dogs with dilated cardiomyopathy treated with carvedilol

Soares, Elaine Cristina 13 January 2006 (has links)
A cardiomiopatia dilatada idiopática (CMD) é a segunda cardiopatia mais prevalente na espécie canina, acometendo principalmente raças grandes e gigantes, bem como o Cocker Spaniel. É uma doença que possui alta letalidade, além de comprometer substancialmente a qualidade de vida do animal. O diagnóstico definitivo é realizado por meio da ecocardiografia, onde se observam dilatação das cavidades cardíacas, mais freqüentemente do ventrículo e átrio esquerdos, e diminuição da função sistólica. Estudos realizados em seres humanos com CMD mostram que, além da sistólica, a função diastólica está comprometida, e que a análise do fluxo transmitral, importante para a detecção de alterações de relaxamento e/ou distensibilidade tem importante valor prognóstico para a sobrevida e evolução dos sintomas. O tratamento da CMD tradicionalmente baseia-se na utilização de digitálicos, diuréticos, e vasodilatadores. Contudo, nos últimos anos, visto a importância da ativação do sistema nervoso simpático sobre a fisiopatologia desta doença, os β-bloqueadores têm sido empregados. Muitos trabalhos mostram que estes fármacos melhoram a função sistólica e/ou diastólica do ventrículo esquerdo, e com isso aumentam a sobrevida e diminuindo a progressão dos sintomas. Estudaram-se 45 cães com cardiomiopatia dilatada, que foram divididos em dois grupos (A e B). O grupo A (n=25) recebeu o tratamento convencional, ou seja, digitálicos, diuréticos e vasodilatadores, e o grupo B (n=20) recebeu estes mesmos medicamentos acrescidos do carvedilol, um β-bloqueador de terceira geração. Os animais foram submetidos aos exames clínico e ecocardiográfico antes e após três, 13, 26 e 52 semanas do início do tratamento ou até o óbito. Não foram observadas diferenças nos valores dos índices de função sistólica e diastólica entre os grupos. Verificou-se que o grupo tratado com carvedilol apresentou maior tempo médio de sobrevida, porém esta diferença não foi estatisticamente significante. Quanto aos sintomas (classe funcional), observou-se que o grupo tratado com carvedilol apresentou evolução mais favorável, com maior número de animais classificados como "sintomas leves" após três meses de tratamento. Assim, embora o carvedilol tenha se mostrado benéfico, principalmente com relação aos sintomas, não se pode correlacionar esta melhora à ação do fármaco sobre as funções sistólica e diastólica / Dilated Cardiomyopathy (DCM) is the second more common heart disease in dogs, wherein large and giant breeds, as well as Cockers Spaniels, are predisposed. Such disease has a high mortality rate besides reducing the quality of life of the affected animals. The definitive diagnosis is based upon echocardiography which is characterized by dilation of cardiac chambers, mainly the left ones, and by reduced systolic function. Human medicine studies have reported that the diastolic dysfunction also plays an important role; so, an abnormal transmitral flow pattern, which represents the ventricular diastolic filling, has a great prognostic value in terms of survival and symptoms status (heart failure functional class) The management of DCM traditionally consists of digitalis, diuretics and vasodilators, however, in the late years, some attention has being paid to the importance of the sympathetic nervous system on the pathophysiology of this disorder; being so, β-blockers have been included in the therapy. Many authors have reported that these drugs improve the left ventricle systolic and diastolic function, and so they increase the survival rate and reduce the symptoms progression. Forty-five dogs with idiopathic dilated cardiomyopathy, divided into two groups (A and B), were studied. The group A (n=25) consisted of dogs that were put on the traditional therapy (digitalis, diuretics and vasodilators) and the group B (n=20) included those who were treated with all these drugs plus carvedilol, a third generation β-blocker. The animals went through clinical and echocardiographic assesment before and 3, 13, 26 and 52 weeks after starting the treatment or until death. The variables of systolic and diastolic function were not statistically different between the two groups. The median survival time of the dogs treated with carvedilol was higher, but the difference was not statistically significant. Concerning to the symptoms (heart failure funcional class), dogs who were put on carvedilol had a better progression, as more of them were classified as "mild symptoms" after three months of therapy. In conclusion, despite the beneficial effects of carvedilol on the symptoms, these can not be correlate with the systolic and diastolic functions
16

Teste de estresse com Dobutamina em cães com Doença Degenerativa Valvar Mitral / Dobutamine stress testing in dogs with Degenerative Mitral Valve Disease

Rodrigues, Bruno Cristian 12 April 2018 (has links)
Submitted by Bruno Cristian Rodrigues (bcr.bruno@hotmail.com) on 2018-05-24T17:50:20Z No. of bitstreams: 1 Dissertação Versão Final.pdf: 1282289 bytes, checksum: 220b5b70a270e2a384dab8b94d207bdc (MD5) / Approved for entry into archive by Alexandra Maria Donadon Lusser Segali null (alexmar@fcav.unesp.br) on 2018-05-28T13:42:27Z (GMT) No. of bitstreams: 1 rodrigues_bc_me_jabo.pdf: 1282289 bytes, checksum: 220b5b70a270e2a384dab8b94d207bdc (MD5) / Made available in DSpace on 2018-05-28T13:42:27Z (GMT). No. of bitstreams: 1 rodrigues_bc_me_jabo.pdf: 1282289 bytes, checksum: 220b5b70a270e2a384dab8b94d207bdc (MD5) Previous issue date: 2018-04-12 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A degeneração mixomatosa da válvula mitral (DMVM) é a enfermidade mais comum na clínica de pequenos animais no âmbito das cardiopatias, cuja evolução pode resultar em alterações hemodinâmicas importantes decorrentes dos mecanismos neuro-hormonais compensatórios. Embora seu diagnóstico seja relativamente simples, as alterações intrínsecas podem ser subestimadas pelos exames convencionais, a exemplo da disfunção sistólica e reserva miocárdica que podem passar despercebidas à ecocardiografia. Desta forma, o objetivo do presente estudo foi avaliar a ocorrência de disfunção sistólica em cães com DMVM por meio do teste de estresse farmacológico com dobutamina. Para tanto, foram utilizados três grupos de cães: G1 (n=8) grupo controle, G2 (n=7) animais com DMVM e diâmetro interno do ventrículo esquerdo em diástole indexado à aorta (DIVEd/Ao) < 2,37 e G3 (n=6) animais com DMVM e DIVEd/Ao ≥ 2,37 em um total de 21 animais. O ecocardiograma foi realizado antes (T0) e após (T1) infusão contínua com dobutamina, que foi realizada da seguinte forma: 5μg/kg/minuto por cinco minutos e 10μg/kg/minuto durante 10 minutos (T1). Os resultados foram avaliados pelo teste de Tukey com nível de significância de 5% quanto às variáveis fração de ejeção (FEJ%) (variação percentual média (VPM) de FEJ% antes e após a infusão de dobutamina), VPM de fração de encurtamento (FEC%) e diâmetros internos do ventrículo esquerdo em sístole e diástole indexados pelo diâmetro da aorta (DIVEs/Ao e DIVEd/Ao). Os resultados acerca da VPM FEC% e VPM FEJ%,demonstraram que houve diferença estatística quanto à primeira variável entre os grupos G1 com G3, bem como entre G2 e G3, enquanto em relação à segunda, apenas o G1 e G3 diferiram estatisticamente. Por outro lado não houve diferença significativa (p>0,05) para as médias obtidas pré e pós dobutamina da FEC% e FEJ% entre todos os grupos, no entanto, houve diferença significativa dentro os grupos G1 e G2 quando analisados os momentos T0 e T1. Outrossim, verificando as médias obtidas do DIVEd/Ao, conclui-se que houve diferença entre os grupos G1 e G3 como também entre G2 e G3 (p<0,05). Por sua vez, as médias obtidas do DIVEs/Ao diferiram significativamente (p<0,05) em todos os grupos pré (T0) e pós dobutamina (T1), exceto no G3. Entre os grupos, as médias no T0, têm diferença estatística significante entre os grupos G1 e G3 (p<0,05). Ademais, Em relação ao VVEs/m², dentro dos grupos houve diferença significativa apenas entre G1 e G3. Já entre os tempos, apenas o G1 houve diferença entre T0 e T1. Por fim, constatou-se significância estatística (p<0,05) quando se correlacionou DIVEd/Ao com a VPM FEC% e VPM FEJ%, demonstrando que quanto maior o DIVEd/Ao menores são estas variáveis. Desta forma, conclui-se que a dobutamina é capaz de evidenciar disfunção sistólica em animais com DMVM, principalmente naqueles que têm um remodelamento maior (G3), sendo capaz de inferir uma forte relação entre o tamanho do DIVEd/Ao e disfunção sistólica. Além disso, notou -se que em animais com menor remodelamento do ventrículo esquerdo (VE), como os do grupo G2, a resposta inotrópica ao desafio farmacológico foi satisfatória, revelando a presença de reserva contrátil nestes pacientes. Por fim, o teste de estresse com dobutamina mostrou-se eficaz, seguro e aplicável na rotina clínica. / Myxomatous mitral valve disease (MMVD) is the most common cardiopathy in small animals, which evolution may result in important hemodynamic changes due to compensatory neurohormonal mechanisms. Although its diagnosis is relatively simple, intrinsic changes may be underestimated by conventional exams, as systolic dysfunction and myocardial reserve that may go unnoticed by echocardiograph. Therefore, the objective of the present study was to evaluate the occurrence of systolic dysfunction in dogs with MMVD through pharmacological stress test with dobutamine. The dogs were distributed in three groups: G1 (n = 8) control group, G2 (n = 7) animals with MMVD and left ventricular diastolic diameter indexed to the aorta (LVIDd:Ao) < 2.37 and G3 (n = 6) animals with MMVD and LVIDd:Ao ≥ 2.37. The echocardiograph was performed before (T0) and after (T1) continuous infusion of dobutamine, as follows: 5μg/kg/minute for five minutes and 10μg/kg/minute for 10 minutes (T1). The results were evaluated by Tukey test with significance level of 5% for the following variables: ejection fraction (EF%) (mean percentage variation (MPV) of EF% before and after dobutamine infusion), MPV of shortening fraction FS% and internal diameters of left ventricle in systole and in diastole indexed by aortic diameter (LVIDs:Ao and LVIDd:Ao). The results about the MPV FS% and the MPV EF% showed that there was statistical difference between the G1 and G3 groups, as well as between G2 and G3, while the G1 and G3 differed statistically from the G1 and G3 groups. On the other hand, there was no significant difference (p> 0.05) for the averages obtained before and after dobutamine of the FS% and EF% among all groups, however, there was a significant difference between groups G1 and G2 when the T0 moments and T1. In addition, it was concluded that there were differences between the G1 and G3 groups as well as between G2 and G3 (p <0.05). Also, by means of the LVIDd:Ao means, it was concluded that there was a difference between the G1 and G3 groups as well as between G2 and G3 (p <0.05). In it’s turn, the means obtained from LVIDs:Ao differed significantly (p <0.05) in all groups before (T0) and post-dobutamine (T1), except in G3. Among the groups, the averages at T0, have significant statistical difference between the G1 and G3 groups (p <0.05). In addition, with respect to ESV/m², within the groups there was a significant difference only between G1 and G3. Among the times, only G1 showed differences between T0 and T1. Finally, statistical significance (p <0.05) was found when DIVEd / Ao correlated with MPV FS% and EF%, demonstrating that the higher the LVIDd:Ao the lower these variables. Therefore, it was determined that dobutamine can point to systolic dysfunction in animals with MMVD, especially those showing greater remodeling (G3), also inferring a strong relationship between LVIDd:Ao size and systolic dysfunction. Furthermore, in animals with less left ventricular (LV) remodeling, such as those in group G2, inotropic response to pharmacological challenge was satisfactory, revealing the presence of contractile reserve in these patients. To conclude, dobutamine stress test showed effective, safe and applicable in clinical routine.
17

Avaliação ecocardiográfica dos índices de função sistólica e diastólica de cães com cardiomiopatia dilatada idiopática submetidos ao tratamento com carvedilol / Echocardiographic evaluation of systolic and diastolic parameters of dogs with dilated cardiomyopathy treated with carvedilol

Elaine Cristina Soares 13 January 2006 (has links)
A cardiomiopatia dilatada idiopática (CMD) é a segunda cardiopatia mais prevalente na espécie canina, acometendo principalmente raças grandes e gigantes, bem como o Cocker Spaniel. É uma doença que possui alta letalidade, além de comprometer substancialmente a qualidade de vida do animal. O diagnóstico definitivo é realizado por meio da ecocardiografia, onde se observam dilatação das cavidades cardíacas, mais freqüentemente do ventrículo e átrio esquerdos, e diminuição da função sistólica. Estudos realizados em seres humanos com CMD mostram que, além da sistólica, a função diastólica está comprometida, e que a análise do fluxo transmitral, importante para a detecção de alterações de relaxamento e/ou distensibilidade tem importante valor prognóstico para a sobrevida e evolução dos sintomas. O tratamento da CMD tradicionalmente baseia-se na utilização de digitálicos, diuréticos, e vasodilatadores. Contudo, nos últimos anos, visto a importância da ativação do sistema nervoso simpático sobre a fisiopatologia desta doença, os &beta;-bloqueadores têm sido empregados. Muitos trabalhos mostram que estes fármacos melhoram a função sistólica e/ou diastólica do ventrículo esquerdo, e com isso aumentam a sobrevida e diminuindo a progressão dos sintomas. Estudaram-se 45 cães com cardiomiopatia dilatada, que foram divididos em dois grupos (A e B). O grupo A (n=25) recebeu o tratamento convencional, ou seja, digitálicos, diuréticos e vasodilatadores, e o grupo B (n=20) recebeu estes mesmos medicamentos acrescidos do carvedilol, um &beta;-bloqueador de terceira geração. Os animais foram submetidos aos exames clínico e ecocardiográfico antes e após três, 13, 26 e 52 semanas do início do tratamento ou até o óbito. Não foram observadas diferenças nos valores dos índices de função sistólica e diastólica entre os grupos. Verificou-se que o grupo tratado com carvedilol apresentou maior tempo médio de sobrevida, porém esta diferença não foi estatisticamente significante. Quanto aos sintomas (classe funcional), observou-se que o grupo tratado com carvedilol apresentou evolução mais favorável, com maior número de animais classificados como &quot;sintomas leves&quot; após três meses de tratamento. Assim, embora o carvedilol tenha se mostrado benéfico, principalmente com relação aos sintomas, não se pode correlacionar esta melhora à ação do fármaco sobre as funções sistólica e diastólica / Dilated Cardiomyopathy (DCM) is the second more common heart disease in dogs, wherein large and giant breeds, as well as Cockers Spaniels, are predisposed. Such disease has a high mortality rate besides reducing the quality of life of the affected animals. The definitive diagnosis is based upon echocardiography which is characterized by dilation of cardiac chambers, mainly the left ones, and by reduced systolic function. Human medicine studies have reported that the diastolic dysfunction also plays an important role; so, an abnormal transmitral flow pattern, which represents the ventricular diastolic filling, has a great prognostic value in terms of survival and symptoms status (heart failure functional class) The management of DCM traditionally consists of digitalis, diuretics and vasodilators, however, in the late years, some attention has being paid to the importance of the sympathetic nervous system on the pathophysiology of this disorder; being so, &beta;-blockers have been included in the therapy. Many authors have reported that these drugs improve the left ventricle systolic and diastolic function, and so they increase the survival rate and reduce the symptoms progression. Forty-five dogs with idiopathic dilated cardiomyopathy, divided into two groups (A and B), were studied. The group A (n=25) consisted of dogs that were put on the traditional therapy (digitalis, diuretics and vasodilators) and the group B (n=20) included those who were treated with all these drugs plus carvedilol, a third generation &beta;-blocker. The animals went through clinical and echocardiographic assesment before and 3, 13, 26 and 52 weeks after starting the treatment or until death. The variables of systolic and diastolic function were not statistically different between the two groups. The median survival time of the dogs treated with carvedilol was higher, but the difference was not statistically significant. Concerning to the symptoms (heart failure funcional class), dogs who were put on carvedilol had a better progression, as more of them were classified as &quot;mild symptoms&quot; after three months of therapy. In conclusion, despite the beneficial effects of carvedilol on the symptoms, these can not be correlate with the systolic and diastolic functions
18

Avaliação ecocardiográfica da sincronia mecânica como marcador de eventos em portadores de insuficiência cardíaca. / Echocardiographic assessment of mechanical synchrony as predictor of events in patients with heart failure.

Barretto, Rodrigo Bellio de Mattos 20 April 2012 (has links)
A ecocardiografia é um importante exame no diagnóstico de insuficiência cardíaca, avaliando as funções, sistólica e diastólica, comprometidas nesta síndrome. Pacientes com insuficiência cardíaca apresentando disfunção sistólica esquerda constituem uma população com alta morbidade e mortalidade, tendo sido descritos diversos parâmetros ecocardiográficos marcadores de prognóstico. Recentemente, desenvolveram-se metodologias que possibilitam avaliar a sincronia mecânica do coração que se apresenta especialmente comprometida nesta população. No entanto, o valor destas medidas em estimar o risco de eventos clínicos adversos é incerto. O objetivo deste estudo foi o de testar se estas medidas ecocardiográficas podem constituir marcadores de eventos cardíacos adversos em pacientes clinicamente estáveis com insuficiência cardíaca e disfunção sistólica esquerda. Duzentos e sete pacientes encaminhados consecutivamente dos ambulatórios de Insuficiência Cardíaca e Miocardiopatias, em condição clínica estável e com medicação otimizada realizaram um ecocardiograma, coletando-se nesta data: dados clínicos, eletrocardiográficos e amostras de sangue. No ecocardiograma, avaliaram-se além das medidas convencionais, aquelas que descrevem a sincronia: atrial esquerda, atrioventricular, interventricular, intraventriculares diastólica e sistólica, esta última por cinco metodologias distintas. Acompanharam-se estes pacientes por 1,5±0.9 anos. Por meio da regressão logística de Cox, analisaram-se estes dados como marcadores dependentes ou independentes de desfecho principal (óbito ou transplante cardíaco) e secundário (óbito, transplante cardíaco ou hospitalização por descompensação da insuficiência cardíaca). As características e frequências mais marcantes do grupo foram: sexo masculino - 64%, idade 58±13 anos, Classe funcional II/III - NYHA 70%, doença arterial coronariana 40%, uso de inibidores de enzima de conversão ou bloqueador dos receptores de angiotensina II 93%, uso de betabloqueadores 90%, intervalo QRS 148±31 ms, bloqueio de ramo esquerdo 57%, diâmetro diastólico do ventrículo esquerdo 72±9 mm, fração de ejeção do ventrículo esquerdo 30±5 %, disfunção diastólica grau III ou IV 46%, insuficiência mitral mais que discreta 19%. Nenhuma variável ecocardiográfica que avalia a sincronia mecânica foi marcadora destes eventos. Na análise multivariada pelo modelo de Cox, as variáveis associadas ao desfecho primário foram: sexo feminino HR, 0,14 (p=0.01), Classe funcional III - NYHA, HR 14,64 (p<0.01), índice de massa cardíaca cada 10 g, HR 1,16 (p<0,01), fração de ejeção do ventrículo esquerdo cada 5%, HR 0,44 (<0,01) e a fração de esvaziamento ativo do átrio esquerdo cada 10%, HR 0,38 (p<0,01). Para o desfecho secundário, as variáveis que se associaram foram: Classe funcional III - NYHA, HR 8,50 (p<0,01), índice de massa cardíaca cada 10 g, HR 1,06 (p=0,04), fração de esvaziamento ativo do átrio esquerdo cada 10%, HR 0,69 (p=0,01) e a integral do Doppler da via de saída do ventrículo esquerdo cada 5 cm, HR 0,65 (p=0,03). Os resultados deste estudo indicam que as medidas ecocardiográficas de sincronia cardíaca não se apresentam como marcadores prognósticos de pacientes clinicamente estáveis, portadores de insuficiência cardíaca com disfunção sistólica esquerda. / Echocardiography is a diagnostic tool to establish clinical diagnosis of heart failure, accurately evaluating heart\'s dysfunction, systolic and/or diastolic, existing in this syndrome. Heart failure patients with systolic left ventricular dysfunction constitute a population with high morbidity and mortality, have being described several echocardiographic prognostic factors. Recently, new methodologies enable the evaluation of mechanical synchrony of the heart that compromises frequently this particular population. However, the value of these measurements to estimate risk of adverse clinical events in such patients is uncertain. The purpose of this study was to test whether these echocardiographic measurements can predict cardiac adverse events in heart failure patients, clinically stable, with left ventricular systolic dysfunction. Two hundred and seven patients referred consecutively from outpatient heart failure clinics, in stable clinical condition, with optimized medication did an echocardiogram collecting also clinical, electrocardiographic data and blood samples. There were evaluated in addition to conventional echocardiographic measurements, those that describe the various types of synchrony: left atrial, atriovenricular, interventricular, intraventricular diastolic and systolic, the latter by five distinct methods. The follow up was 1.5 ± 0.9 years. By Cox regression, we analyzed if these data were dependent or independent predictors of primary (death or cardiac transplantation) and secondary outcome (death, heart transplantation or hospitalization for heart failure decompensation). The most remarkable features and frequencies of this group were: male gender- 64%, age 58 ± 13 years, functional class II / III - NYHA 70%, known coronary artery disease 40%, use of converting enzyme inhibitor or receptor blocker angiotensin II 93%, beta-blockers 90%, QRS interval 148 ± 31 ms, left bundle branch block 57%, left ventricular diastolic diameter 72 ± 9 mm, left ventricular ejection fraction 30 ± 5%, diastolic dysfunction grade III or IV 46%, mitral regurgitation - more than mild 19%. None of the echocardiographic variables that evaluate mechanical synchrony predicted these events. On Cox multivariate regression, the variables associated to the primary outcome were: female gender, HR 0.14 (p = 0.01), functional class III - NYHA, HR 14.64 (p <0.01), cardiac mass index - every 10 g, HR 1.16 (p <0.01), ejection fraction, left ventricular - every 5 %, HR 0.44 (p <0.01) and left atrial active emptying fraction - every 10%, HR 0.38 (p <0.01). For the secondary outcome, the variables associated were: functional class III - NYHA, HR 8.50 (p <0.01), cardiac mass index - every 10 g, HR 1, 06 (p = 0.04), left atrial active emptying fraction - every 10%, HR 0.69 (p = 0.01) and the integral of left ventricle outflow Doppler - every 5 cm, HR 0.65 (p= 0.03). The results of this study indicate that echocardiographic measurements of cardiac synchrony are not predictors of cardiac events of clinically stable heart failure patients with systolic left ventricular dysfunction.
19

ASSESSMENT OF THE INTENSITY OF THE EFFORT OF COFFE PICKERS IN DIFFERENT STAGES OF THE MANUAL PICKING 2006. / ESTUDO DA INTENSIDADE DO ESFORÇO DOS COLHEITADORES NA ATIVIDADE DA COLHEITA MANUAL DO CAFÉ

Cláudio Silva Porto 04 August 2006 (has links)
lt;p align="justify"gt; The present work aimed to assess the intensity of effort of the coffee pickers in different stages of the manual coffee picking, by means of the Heartbeat Frequency, Systolic Arterial Pressure and rate pressure-product, during the three stages of the coffee harvest, in the city of Caratinga-MG. 154 workers were selected and assessed, 77 men and 77 women. The sampling consisted of coffee pickers, with ages ranging between 18 to 57. The design of this work took place in four distinguished moments. Firstly, all the farm workers selected were submitted to a top benchmark test, to assess the maximum *VO2 , maximum rate-pressure product of the workers, through the Balke Protocol (MARINS amp; GIANNICHI, 1998). In a second moment, with the maximum *VO2 results available, the farm workers were compared and classified according to the Aerobic Conditioning Classification Chart for men and women. In a third stage, the heartbeat rate, arterial pressure and rate pressure-product were measured during the stages of: cropping, gathering and fanning. In stage four, the values of heartbeat rate, arterial pressure and rate pressure-product obtained in the three stages of the coffee picking were compared by means of statistical analysis, to determine the statistically significant difference of the values of work load. In the VO2max, classification, there can be noticed that 18 men and 26 women, representing 23.37% and 33.77% , respectively, were qualified as GOOD, for the Balke benchmark test; 41 men and 47 women, 53.25% and 61.03%, classified as REGULAR; 16 men (20.78%) and 3 women (3.90%) classified as BAD; and 2 men (2.60%) and 1 woman (1.30%) classified as VERY BAD. There was a significant increase of the heartbeat rate in all three stages of the harvest as related to heartbeat rate when at rest. It was also assessed that the highest mean values, for both genders, was during the Gathering stage (115.2bpm for the men and 105.3bpm for the women), followed by the Fanning (105.6bpm for the men and 108bpm for the women) and Dropping 91.8bpm for the men and 105.3 for the women), respectively. The mean values found for the heartbeat rates characterize the stages of dropping and fanning of the coffee as reasonably mild, for both the genders, with relative values from 50.28% to 60.81% for the Max. heartbeat rate or 28% to 40% of the VO2max. The values found in the gathering stage, of 63.09% of the max. heartbeat rate for the men, classifies this stage as Reasonably Mild; for the women, the percentage of 69.36 max Heartbeat rate classifies this stage as Rather Hard. The gathering stage recorded the highest mean values of arterial pressure for both the genders (137.40mm Hg for the men and 137.79mm Hg for the women), followed by Fanning (132.68mm Hg foe the men and 134.63mm Hg for the women) and Dropping (129.87 mm Hg for the men and 128.87mm Hg for the women), respectively. In the stages of Dropping and Gathering there was no Significant Difference in the results, regarding genders. The highest mean vales of rate pressure-product found in the three stages of the coffee harvesting were, respectively: 15836.58 for the men, and 16995.06 for the women in the Gathering stage; 14000.43 for the men and 14563.8 for the women in the Fanning; and 11944.3 for the men and 13574.3 for the women in the Dropping stage.lt;/pgt; / lt;p align="justify"gt; O presente trabalho teve como objetivo avaliar a intensidade de esforço dos colheitadores de café, através da Freqüência Cardíaca, Pressão Arterial Sistólica e Duplo Produto, durante as três etapas da colheita do café, no município de Caratinga – MG. Foram selecionados e avaliados 154 trabalhadores, sendo 77 do sexo masculino e 77 do sexo feminino. A amostra foi de colheitadores de café, na faixa etária entre 18 e 57 anos de idade. O processo de construção deste trabalho ocorreu em quatro (04) momentos distintos. No primeiro momento, todos os trabalhadores rurais selecionados foram submetidos a um teste máximo de banco, para estimar o de VO2max. e o duplo produto máx., através do Protocolo de Balke (MARINS amp; GIANNICHI, 1998). No segundo momento, com resultados do teste VO2max., os trabalhadores rurais foram comparados e classificados de acordo com a Tabela de Classificação do Condicionamento Aeróbio de Homens e Mulheres. No terceiro momento, foi avaliada a freqüência cardíaca, a pressão arterial e o duplo produto dos trabalhadores rurais durante as etapas de: derriça, recolhimento e abanação. No quarto momento, os valores de freqüência cardíaca, pressão arterial e duplo produto, obtidos nas etapas da colheita, foram comparados através da análise estatística, para determinar as diferenças significativas dos valores da carga de trabalho. Na classificação do VO2max, pode-se observar que 18 homens e 26 mulheres, que representam 23,37% e 33,77%, respectivamente, foram classificados como BOM, no teste de banco de Balke; 41 homens e 47 mulheres, 53,25% e 61,03%, classificados como REGULAR; 16 homens (20,78%) e 03 mulheres (3,90%), classificados como RUIM; e 02 homens (2,60%) e 01 mulher (1,30%) classificados como MUITO RUIM. Observaram-se maiores valores médios, em ambos os sexos, na etapa de Recolhimento (115,2 bpm para os homens e, 123,2 bpm para as mulheres), seguido pela Abanação (105,6 bpm para os homens e, 108 bpm para as mulheres) e Derriça (91,8 bpm para os homens e, 105,3 bpm para as mulheres), respectivamente. Os valores médios de freqüência cardíaca encontrados caracterizam as etapas de derriça e abanação de café como Razoavelmente Leve, para ambos os sexos, com valores relativos entre 50,28% a 60,81% da FCmáx ou 28% a 40% do VO2 máx. Os valores encontrados na etapa de recolhimento, de 63,09% da FCmáx para os homens, classifica a etapa como Razoavelmente Leve; para as mulheres, o percentual de 69,36% da Fcmáx, classifica a etapa como Bastante Dura. Foram observados maiores valores médios de Pressão Arterial, em ambos os sexos, na etapa de Recolhimento (137,40 mm Hg para os homens e, 137,79 mm Hg para as mulheres), seguido pela Abanação (132,68 mm Hg para os homens e, 134,63 mm Hg para as mulheres) e Derriça (129,87 mm Hg para os homens e, 128,87 mm Hg para as mulheres), respectivamente. Nas etapas de Derriça e Recolhimento não houve diferença significativa nos resultados, em relação ao sexo. Os maiores valores médios de DP encontrados nas três etapas da colheita de café foram, respectivamente: na etapa Recolhimento, 15836,58 para os homens e 16995,06 para as mulheres; na etapa Abanação, 14000,43 para os homens e 14563,8 para as mulheres; na etapa Derriça, 11944,3 para os homens e 13574,3 para as mulheres.lt;/pgt;
20

Avaliação ecocardiográfica da sincronia mecânica como marcador de eventos em portadores de insuficiência cardíaca. / Echocardiographic assessment of mechanical synchrony as predictor of events in patients with heart failure.

Rodrigo Bellio de Mattos Barretto 20 April 2012 (has links)
A ecocardiografia é um importante exame no diagnóstico de insuficiência cardíaca, avaliando as funções, sistólica e diastólica, comprometidas nesta síndrome. Pacientes com insuficiência cardíaca apresentando disfunção sistólica esquerda constituem uma população com alta morbidade e mortalidade, tendo sido descritos diversos parâmetros ecocardiográficos marcadores de prognóstico. Recentemente, desenvolveram-se metodologias que possibilitam avaliar a sincronia mecânica do coração que se apresenta especialmente comprometida nesta população. No entanto, o valor destas medidas em estimar o risco de eventos clínicos adversos é incerto. O objetivo deste estudo foi o de testar se estas medidas ecocardiográficas podem constituir marcadores de eventos cardíacos adversos em pacientes clinicamente estáveis com insuficiência cardíaca e disfunção sistólica esquerda. Duzentos e sete pacientes encaminhados consecutivamente dos ambulatórios de Insuficiência Cardíaca e Miocardiopatias, em condição clínica estável e com medicação otimizada realizaram um ecocardiograma, coletando-se nesta data: dados clínicos, eletrocardiográficos e amostras de sangue. No ecocardiograma, avaliaram-se além das medidas convencionais, aquelas que descrevem a sincronia: atrial esquerda, atrioventricular, interventricular, intraventriculares diastólica e sistólica, esta última por cinco metodologias distintas. Acompanharam-se estes pacientes por 1,5±0.9 anos. Por meio da regressão logística de Cox, analisaram-se estes dados como marcadores dependentes ou independentes de desfecho principal (óbito ou transplante cardíaco) e secundário (óbito, transplante cardíaco ou hospitalização por descompensação da insuficiência cardíaca). As características e frequências mais marcantes do grupo foram: sexo masculino - 64%, idade 58±13 anos, Classe funcional II/III - NYHA 70%, doença arterial coronariana 40%, uso de inibidores de enzima de conversão ou bloqueador dos receptores de angiotensina II 93%, uso de betabloqueadores 90%, intervalo QRS 148±31 ms, bloqueio de ramo esquerdo 57%, diâmetro diastólico do ventrículo esquerdo 72±9 mm, fração de ejeção do ventrículo esquerdo 30±5 %, disfunção diastólica grau III ou IV 46%, insuficiência mitral mais que discreta 19%. Nenhuma variável ecocardiográfica que avalia a sincronia mecânica foi marcadora destes eventos. Na análise multivariada pelo modelo de Cox, as variáveis associadas ao desfecho primário foram: sexo feminino HR, 0,14 (p=0.01), Classe funcional III - NYHA, HR 14,64 (p<0.01), índice de massa cardíaca cada 10 g, HR 1,16 (p<0,01), fração de ejeção do ventrículo esquerdo cada 5%, HR 0,44 (<0,01) e a fração de esvaziamento ativo do átrio esquerdo cada 10%, HR 0,38 (p<0,01). Para o desfecho secundário, as variáveis que se associaram foram: Classe funcional III - NYHA, HR 8,50 (p<0,01), índice de massa cardíaca cada 10 g, HR 1,06 (p=0,04), fração de esvaziamento ativo do átrio esquerdo cada 10%, HR 0,69 (p=0,01) e a integral do Doppler da via de saída do ventrículo esquerdo cada 5 cm, HR 0,65 (p=0,03). Os resultados deste estudo indicam que as medidas ecocardiográficas de sincronia cardíaca não se apresentam como marcadores prognósticos de pacientes clinicamente estáveis, portadores de insuficiência cardíaca com disfunção sistólica esquerda. / Echocardiography is a diagnostic tool to establish clinical diagnosis of heart failure, accurately evaluating heart\'s dysfunction, systolic and/or diastolic, existing in this syndrome. Heart failure patients with systolic left ventricular dysfunction constitute a population with high morbidity and mortality, have being described several echocardiographic prognostic factors. Recently, new methodologies enable the evaluation of mechanical synchrony of the heart that compromises frequently this particular population. However, the value of these measurements to estimate risk of adverse clinical events in such patients is uncertain. The purpose of this study was to test whether these echocardiographic measurements can predict cardiac adverse events in heart failure patients, clinically stable, with left ventricular systolic dysfunction. Two hundred and seven patients referred consecutively from outpatient heart failure clinics, in stable clinical condition, with optimized medication did an echocardiogram collecting also clinical, electrocardiographic data and blood samples. There were evaluated in addition to conventional echocardiographic measurements, those that describe the various types of synchrony: left atrial, atriovenricular, interventricular, intraventricular diastolic and systolic, the latter by five distinct methods. The follow up was 1.5 ± 0.9 years. By Cox regression, we analyzed if these data were dependent or independent predictors of primary (death or cardiac transplantation) and secondary outcome (death, heart transplantation or hospitalization for heart failure decompensation). The most remarkable features and frequencies of this group were: male gender- 64%, age 58 ± 13 years, functional class II / III - NYHA 70%, known coronary artery disease 40%, use of converting enzyme inhibitor or receptor blocker angiotensin II 93%, beta-blockers 90%, QRS interval 148 ± 31 ms, left bundle branch block 57%, left ventricular diastolic diameter 72 ± 9 mm, left ventricular ejection fraction 30 ± 5%, diastolic dysfunction grade III or IV 46%, mitral regurgitation - more than mild 19%. None of the echocardiographic variables that evaluate mechanical synchrony predicted these events. On Cox multivariate regression, the variables associated to the primary outcome were: female gender, HR 0.14 (p = 0.01), functional class III - NYHA, HR 14.64 (p <0.01), cardiac mass index - every 10 g, HR 1.16 (p <0.01), ejection fraction, left ventricular - every 5 %, HR 0.44 (p <0.01) and left atrial active emptying fraction - every 10%, HR 0.38 (p <0.01). For the secondary outcome, the variables associated were: functional class III - NYHA, HR 8.50 (p <0.01), cardiac mass index - every 10 g, HR 1, 06 (p = 0.04), left atrial active emptying fraction - every 10%, HR 0.69 (p = 0.01) and the integral of left ventricle outflow Doppler - every 5 cm, HR 0.65 (p= 0.03). The results of this study indicate that echocardiographic measurements of cardiac synchrony are not predictors of cardiac events of clinically stable heart failure patients with systolic left ventricular dysfunction.

Page generated in 0.0422 seconds