1

Värmeförluster från kulvertar

Valtersson, Johanna January 2013 (has links)
I den har rapporten kartläggs och bedöms omfattningen av värmeförluster från kulvertar i Landstinget Kronobergs sekundära fjärrvärmenät på Sigfridsområdet. Teoretiska stationära värmeförlustberäkningar har utförts med Petter Wallenténs samband från 1991 samt med det via internet tillgängliga beräkningsprogrammet Logstor Calculator 2.1. Beräkningar över energibesparingen vid ett byte av de äldsta kulvertarna i det sekundära nätet till nya kulvertar visar att tvillingkulvertar i isolerklass 2 är att föredra framför enkelrör både i isolerklass 2 såväl som 3. Rapporten behandlar miljöaspekter kring fjärrvärme samt möjligheter och konsekvenser kring en energieffektivisering av distributionen genom sänkta systemtemperaturer.
2

Enantioselektiv HPLC-analys med kirala stationärfaser bestående av makrocykliska glykopeptider och polysackarider / Enantioselective HPLC-analysis using macrocyclic glycopeptides and polysaccharide based chiral stationary phases

Bergman, Caroline January 2010 (has links)
<p>The purpose of this study was to evaluate enantioselective analytical methods by separation of the enantiomers of four drugs (citalopram, zopiclone, tramadol and methylphenidate) and their metabolites. The analyses were performed with HPLC-UV with columns whose stationary phases were based on macrocyclic glycopeptides (Chirobiotic V, V2 and T) and polysaccharides (Lux Cellulose-1, Cellulose-2 and Amylose-2).</p><p>The Chirobiotic V column showed high selectivity for citalopram and its metabolites. High resolution was obtained using a mobile phase consisting of methanol, acetic acid and ammonia. High selectivity for the enantiomers of zopiclone and its metabolites were obtained on the Cellulose-2 column using a mobile phase consisting of acetonitrile and ammonium acetate buffer.</p><p>The enantiomers of tramadol were separated with the Amylose-2 column. However, changes in the pressure arose, probably caused by the additive NH<sub>4</sub>HCO<sub>3</sub>. When the analysis was repeated at a later occasion, reproducible results were not obtained. With the Cellulose-1 column, lower selectivity was obtained, resulting in unacceptably long analysis time.</p><p>Only a few analyses of methylphenidate were performed and the results indicated that the glycopeptide columns had higher selectivity for this compound than the polysaccharides.</p>
3

Enantioselektiv HPLC-analys med kirala stationärfaser bestående av makrocykliska glykopeptider och polysackarider / Enantioselective HPLC-analysis using macrocyclic glycopeptides and polysaccharide based chiral stationary phases

Bergman, Caroline January 2010 (has links)
The purpose of this study was to evaluate enantioselective analytical methods by separation of the enantiomers of four drugs (citalopram, zopiclone, tramadol and methylphenidate) and their metabolites. The analyses were performed with HPLC-UV with columns whose stationary phases were based on macrocyclic glycopeptides (Chirobiotic V, V2 and T) and polysaccharides (Lux Cellulose-1, Cellulose-2 and Amylose-2). The Chirobiotic V column showed high selectivity for citalopram and its metabolites. High resolution was obtained using a mobile phase consisting of methanol, acetic acid and ammonia. High selectivity for the enantiomers of zopiclone and its metabolites were obtained on the Cellulose-2 column using a mobile phase consisting of acetonitrile and ammonium acetate buffer. The enantiomers of tramadol were separated with the Amylose-2 column. However, changes in the pressure arose, probably caused by the additive NH4HCO3. When the analysis was repeated at a later occasion, reproducible results were not obtained. With the Cellulose-1 column, lower selectivity was obtained, resulting in unacceptably long analysis time. Only a few analyses of methylphenidate were performed and the results indicated that the glycopeptide columns had higher selectivity for this compound than the polysaccharides.
4

Kontextmedvetenhet i stationära spel: En studie om tidsmässig separation mellan speltillfälle och kontextuell data

Rosengren, Simon, Viktorsson, Ludvig January 2018 (has links)
Kontextmedvetna spel låter den reella omgivningenpåverka aspekter av spelinnehållet. Då kontextmedvetna spel i en mobil miljö är ett väl utforskat område saknas forskning kring dess möjlighet att även fungera i en stationär miljö. I denna utforskande studie har en modifikation till det stationära spelet Cities: Skylines utvecklats som låter spelarens aktivitet påverka nästkommande spelsession. Modifikationen har sedan använts vid en användarstudie som undersökt hur denna typ av mer löst kopplade kontext där spel och kontext är tidsmässigt separerade påverkar spelarens upplevelse. Studien visar att denna typ av kontextmedvetenhet upplevs önskvärt. Det kan dock krävas någon form av hjälpande länk som förstärker kopplingen mellan spel och kontext samt att kontextmedvetenhetens syfte bör vara att förstärka spelupplevelsen snarare än att vara en drivande faktor.
5

Tidsrapporteringssystem för mobila och stationära enheter : Utveckling av en MVC4 Webbapplikation i ASP.NET och PhoneGap / Timesheet system for mobile and stationary devices : Development of a MVC4 Web Application in ASP.NET and PhoneGap

Gandhi, Vicky, Kufa, David January 2014 (has links)
Målet med detta projekt var att utforma ett tidsrapporteringssystem åt Online CC AB för att effektivisera deras kunders tidsrapportering. Systemet är en webbapplikation som ska användas till att rapportera in tid som framdeles kan exporteras till valfritt lönesystem för lönehante-ring av personal. Detta system är grunden för ett framtida, fulländat system som har utökad funktionalitet. Produkten togs fram med Ex-treme Programming samt testdriven utveckling. Under utvecklingen jobbade utvecklingsgruppen med välkända och beprövade metoder för att säkerställa ett system av hög kvalité. Webbapplikationen nyttjar moderna teknologier och ramverk för webbutveckling – inklusive Microsofts ASP.NET MVC 4 och Entity Framework. Det visade sig att apputveckling är ett diffust område där de senaste verktygen inom verksamhetsgrenen inte förhållandevis förenklade arbetet. Ett system som fungerar såväl på mobila enheter, i form av en hybridapplikation, som stationära enheter, som webbapplikation, krävde att utvecklings-gruppen var erfarna inom respektive områden. I slutet av projektet var inte alla ställda krav uppfyllda - men eftersom vi använder oss av testdriven utveckling så är systemet fullt operationsdugligt. De krav som implementerades, gjordes det till fullo. Till sist så kan det visa sig att de senaste teknologierna och ramverken inte alltid är de bästa att nyttja. Mer beprövade metoder och teknologier kan i vissa fall vara mer lämpliga. / The goal of this project was to design a timesheet system for Online CC AB in order to make time reporting more efficient for their customers. The system is a web application that is to be used for time reporting in-which, later on can be exported to a salary system of their choice for salary transactions of personnel. This system is the foundation for a future, all-in-one system with extended functionality. The product was produced using Extreme Programming and Test-Driven Development. During development the development team worked with well-renowned and well-tried methods to ensure a system with the utmost quality. The web application utilizes modern technologies and frame-works for web development – including Microsoft’s ASP.NET MVC 4 and Entity Framework. It’s shown that app development is a diffuse field in which the latest tools within the field do not comparatively simplify the work. A system that works on as-well as mobile units, in the form of a hybrid application, as stationary units, in the form of a web application, demands the development team to be experienced within respective fields. At the end of the project not all requirements are met – however due to us using Test-Driven Development, the system is fully operational. Those requirements that were implemented are done so fully. Furthermore, it’s shown that the latest technologies and frame-works not always are best-suited for usage. More well-tried methods and technologies can in some cases be more appropriate
6

Robust and Durable Vacuum Insulation Technology for Buildings

Karami, Peyman January 2015 (has links)
Today’s buildings are responsible for 40% of the world’s energy use and also a substantial share of the Global Warming Potential (GWP). In Sweden, about 21% of the energy use can be related to the heat losses through the climatic envelope. The “Million Program” (Swedish: Miljonprogrammet) is a common name for about one million housing units, erected between 1965 and 1974 and many of these buildings suffer from poor energy performance. An important aim of this study was to access the possibilities of using Vacuum Insulation Panels (VIPs) in buildings with emphasis on the use of VIPs for improving the thermal efficiency of the “Million Program” buildings. The VIPs have a thermal resistance of about 8-10 times better than conventional insulations and offer unique opportunities to reduce the thickness of the thermal insulation. This thesis is divided into three main subjects. The first subject aims to investigate new alternative VIP cores that may reduce the market price of VIPs. Three newly developed nanoporous silica were tested using different steady-state and transient methods. A new self-designed device, connected to a Transient Plane Source (TPS) instrument was used to determine the thermal conductivity of granular powders at different gaseous pressure combined with different mechanical loads. The conclusion was that the TPS technique is less suitable for conducting thermal conductivity measurements on low-density nanoporous silica powders. However, deviations in the results are minimal for densities above a limit at which the pure conduction becomes dominant compared to heat transfer by radiation. The second subject of this work was to propose a new and robust VIP mounting system, with minimized thermal bridges, for improving the thermal efficiency of the “Million Program” buildings. On the basis of the parametric analysis and dynamic simulations, a new VIP mounting system was proposed and evaluated through full scale measurements in a climatic chamber. The in situ measurements showed that the suggested new VIP technical solution, consisting of 20mm thick VIPs, can improve the thermal transmittance of the wall, up to a level of 56%. An improved thermal transmittance of the wall at centre-of-panel coordinate of 0.118 to 0.132 W m-2K-1 and a measured centre-of-panel thermal conductivity (λcentre-of-panel) of 7 mW m-1K-1 were reached. Furthermore, this thesis includes a new approach to measure the thermal bridge impacts due to the VIP joints and laminates, through conducting infrared thermography investigations. An effective thermal conductivity of 10.9 mW m-1K-1 was measured. The higher measured centre-of-panel and effective thermal conductivities than the published centre-of-panel thermal conductivity of 4.2 mW m-1K-1 from the VIP manufacturer, suggest that the real thermal performance of VIPs, when are mounted in construction, is comparatively worse than of the measured performance in the laboratory. An effective thermal conductivity of 10.9 mW m-1K-1 will, however, provide an excellent thermal performance to the construction. The third subject of this thesis aims to assess the environmental impacts of production and operation of VIP-insulated buildings, since there is a lack of life cycle analysis of whole buildings with vacuum panels. It was concluded that VIPs have a greater environmental impact than conventional insulation, in all categories except Ozone Depilation Potential. The VIPs have a measurable influence on the total Global Warming Potential and Primary Energy use of the buildings when both production and operation are taken into account. However, the environmental effect of using VIPs is positive when compared to the GWP of a standard building (a reduction of 6%) while the PE is increased by 20%. It was concluded that further promotion of VIPs will benefit from reduced energy use or alternative energy sources in the production of VIP cores while the use of alternative cores and recycling of VIP cores may also help reduce the environmental impact. Also, a sensitivity analysis of this study showed that the choice of VIPs has a significant effect on the environmental impacts, allowing for a reduction of the total PE of a building by 12% and the GWP can be reduced as much as 11% when considering both production and operation of 50 yes. Finally, it’s possible to conclude that the VIPs are very competitive alternative for insulating buildings from the Swedish “Million Program”. Nevertheless, further investigations require for minimizing the measurable environmental impacts that acquired in this LCA study for the VIP-insulated buildings. / Dagens byggnader ansvarar för omkring 40% av världens energianvändning och  står också för en väsentlig del av utsläppen av växthusgaser. I Sverige kan ca 21 % av energianvändningen relateras till förluster genom klimatskalet. Miljonprogrammet är ett namn för omkring en miljon bostäder som byggdes mellan 1965 och 1974, och många av dessa byggnader har en dålig energiprestanda efter dagens mått. Huvudsyftet med denna studie har varit att utforska möjligheterna att använda vakuumisoleringspaneler (VIP:ar) i byggnader med viss fokus på tillämpning i Miljonprogrammets byggnader. Med en värmeledningsförmåga som är ca 8 - 10 gånger bättre än för traditionell isolering erbjuder VIP:arna unika möjligheter till förbättrad termisk prestanda med minimal isolerings tjocklek. Denna avhandling hade tre huvudsyften. Det första var att undersöka nya alternativ för kärnmaterial som bland annat kan reducera kostnaden vid produktion av VIP:ar. Tre nyutvecklade nanoporösa kiselpulver har testats med olika stationära och transienta metoder. En inom projektet utvecklad testbädd som kan anslutas till TPS instrument (Transient Plane Source sensor), har använts för att mäta värmeledningsförmågan hos kärnmaterial för VIP:ar, vid varierande gastryck och olika mekaniska laster. Slutsatsen blev att transienta metoder är mindre lämpliga för utföra mätningar av värmeledningsförmåga för nanoporösa kiselpulver låg densitet. Avvikelsen i resultaten är dock minimal för densiteter ovan en gräns då värmeledningen genom fasta material blir dominerande jämfört med värmeöverföring genom strålning. Det andra syftet har varit att föreslå ett nytt monteringssystem för VIP:ar som kan användas för att förbättra energieffektiviteten i byggnader som är typiska för Miljonprogrammet. Genom parametrisk analys och dynamiska simuleringar har vi kommit fram till ett förslag på ett nytt monteringssystem för VIP:ar som har utvärderats genom fullskaleförsök i klimatkammare. Resultaten från fullskaleförsöken visar att den nya tekniska lösningen förbättrar väggens U-värde med upp till 56 %. En förbättrad värmegenomgångskoefficienten för väggen i mitten av en VIP blev mellan 0.118 till 0,132 W m-2K-1 och värmeledningstalet centre-av-panel 7 mW m-1K-1 uppnåddes. Detta arbete innehåller dessutom en ny metod för att mäta köldbryggor i anslutningar med hjälp av infraröd termografi. En effektiv värmeledningsförmåga för 10.9 mW m-1K-1 uppnåddes. Resultaten tyder även på att den verkliga termiska prestandan av VIP:ar i konstruktioner är något sämre än mätvärden för paneler i laboratorium. En effektiv värmeledningsförmåga av 10.9 mW m-1K-1 ger dock väggkonstruktionen en utmärkt termisk prestanda. Det tredje syftet har varit att bedöma miljöpåverkan av en VIP-isolerad byggnad, från produktion till drift, eftersom en livscykelanalys av hela byggnader som är isolerade med vakuumisoleringspaneler inte har gjorts tidigare. Slutsatsen var att VIP:ar har en större miljöpåverkan än traditionell isolering, i alla kategorier förutom ozonnedbrytande potential. VIP:ar har en mätbar påverkan på de totala utsläppen av växthusgaser och primärenergianvändningen i byggnader när både produktion och drift beaktas. Miljöpåverkan av de använda VIP:arna är dock positiv jämfört med GWP av en standardbyggnad (en minskning med 6 %) medan primärenergianvändningen ökade med 20 %. Slutsatsen var att ytterligare användning av VIP:ar gynnas av reducerad energiförbrukning och alternativa energikällor i produktionen av nanoporösa kiselpulver medan användningen av alternativa kärnmaterial och återvinning av VIP kärnor kan hjälpa till att minska miljöpåverkan. En känslighetsanalys visade att valet av VIP:ar har en betydande inverkan på miljöpåverkan, vilket ger möjlighet att reducera den totala användningen av primärenergi i en byggnad med 12 % och utsläppen av växthusgaser kan vara minska, så mycket som 11 % när det gäller både produktion och drift under 50 år. Avslutningsvis är det möjligt att dra slutsatsen att VIP:ar är ett mycket konkurrenskraftigt alternativ för att isolera byggnader som är typiska för Miljonprogrammet. Dock krävs ytterligare undersökningar för att minimera de mätbara miljöeffekter som förvärvats i denna LCA-studie för VIP-isolerade byggnader. / <p>QC 20151109</p> / Simulations of heat and moisture conditions in a retrofit wall construction with Vacuum Insulation Panels / Textural and thermal conductivity properties of a low density mesoporous silica material / A study of the thermal conductivity of granular silica materials for VIPs at different levels of gaseous pressure and external loads / Evaluation of the thermal conductivity of a new nanoporous silica material for VIPs – trends of thermal conductivity versus density / A comparative study of the environmental impact of Swedish residential buildings with vacuum insulation panels / ETICS with VIPs for improving buildings from the Swedish million unit program “Miljonprogrammet”