• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 26
  • 26
  • 20
  • 16
  • 11
  • 8
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeito do tratamento de superficie e armazenamento na resistencia da união entre resina composta indireta e cimento auto-adesivo / Effect of surface treatment and storage on bond strenght between indirect composite and self-adhesive cement

Antunes, Alberto Nogueira da Gama 26 February 2007 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T12:49:05Z (GMT). No. of bitstreams: 1 Antunes_AlbertoNogueiradaGama_M.pdf: 2715470 bytes, checksum: f02dda3ea737577e7f386991ff69db32 (MD5) Previous issue date: 2007 / Resumo: Este estudo avaliou o efeito de diferentes tratamentos na superfície de resina composta utilizada para restaurações indiretas e do armazenamento em água na resistência de união com cimento auto-adesivo. Quarenta blocos cilíndricos de compósito MZ100 com dimensões de 4x10mm (altura x diâmetro) foram cimentados dois a dois com o cimento RelyX Unicem. Vinte corpos-deprova foram divididos, em cinco grupos de acordo com o tratamento de superfície. G1 (controle)- Sem tratamento; G2- Jateamento com partículas de óxido de alumínio (Al2O3); G3- Aplicação do condicionador de metal; G4- Jateamento com partículas de óxido de alumínio seguido da aplicação do condicionador de metal; G5- Jateamento com partículas de óxido de alumínio e aplicação do silano. Após a cimentação (24 horas), os conjuntos foram seccionados, produzindo espécimes em forma de palito com aproximadamente 0,8mm2 de área. Após a obtenção dos palitos, o ensaio de tração foi executado, em uma máquina de ensaio universal (Instron) sob velocidade de 0,5mm/min em dois períodos de tempo: 48 horas e 40 dias após a cimentação. As médias de resistência de união em 48 horas foram G1 = 45,48MPa; G2 = 47,17MPa; G3 = 36,16MPa; G4 = 41,68MPa; G5 = 45,84MPa. Após quarenta dias de armazenamento as médias de resistência de união foram: G1 = 48,07MPa; G2 = 42,56MPa; G3 = 37,84MPa; G4 = 34,17MPa; G5 = 45,59MPa. No período de teste de 48 horas e 40 dias a aplicação do condicionador de metal resultou em valores de resistência de união menores em relação aos outros tratamentos. O armazenamento de quarenta dias produziu redução estatisticamente significativa na resistência de união para o G4. Os demais grupos não apresentaram diferenças estatisticamente significante (p>0,05) / Abstract: The aim of this study was to evaluate the effect of different treatments and water storage on bond strength of an indirect resin cemented using self-adhesive luting cement. Forty cylindrical blocks (4X10mm) were cemented together in pairs using RelyX Unicem cement. Twenty samples were divided in groups of five according to surface treatment. G1 (control)- no surface treatment was applied; G2- Surface was sandblasted with Al2O3 particles; G3- surface was treated with metal conditioner; G4- samples were sandblasted with Al2O3 particles and metal conditioner was applied; G5- samples were sandblasted with Al2O3 and silane agent was applied. The pairs were sectioned twenty four hours after cementation, producing beams with cross-section area of 0.8mm2 approximately. Microtensile testing was performed 48 hours and 40 days after luting procedure using a universal testing machine (Instrom) at a crosshead speed of 0,5mm/min. The means obtained for microtensile bond strength after 24 hours were: G1 = 45.48MPa; G2 = 47.17MPa; G3 = 36.16MPa; G4 = 41.68MPa; G5 = 45.84MPa. After forty days of storage the means obtained for microtensile bond strength were: G1= 48.07MPa; G2 = 42.56MPa; G3= 37.84MPa; G4 = 34.17MPa; G5 = 45.59MPa. After 48 hours and 40 days, the application of Alloy primer resulted in the lowest microtensile bond strength values when compared to all the other treatments. Water storage for 40 days produced a statistically significant reduction of microtensile bond strength values for group G4. Other groups did not reveal statistically significant reduction of bond strength after storage (p>0,05) / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
12

Efeito do tempo de aplicação de gel antioxidante sobre a resistencia de união ao esmalte dental clareado / Effect that elapsed time of antioxidant gel onto the bond strenght to bleached enamel

Silva, Ana Paula Brito da 15 December 2006 (has links)
Orientador: Giselle Maria Marchi Baron / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T12:14:43Z (GMT). No. of bitstreams: 1 Silva_AnaPaulaBritoda_M.pdf: 4666067 bytes, checksum: 6eaa4a564293d2a7a9e71635aad24d2f (MD5) Previous issue date: 2006 / Resumo: O objetivo deste estudo in vitro foi avaliar o efeito do tempo de aplicação de gel de ascorbil a 3% (AE) sobre a resistência de união ao esmalte bovino tratado previamente com peróxido de carbamida a 10% (PC), estabelecendo o padrão de fratura através de microscopia eletrônica de varredura (MEV). Sessenta incisivos bovinos foram selecionados, limpos e armazenados em solução salina de timol a 0,1%. Sessenta fragmentos de 25mm2 foram obtidos da superfície vestibular, utilizando-se discos diamantados de dupla-face, em baixa rotação, sob constante irrigação. Os fragmentos foram cobertos com fina camada de cera 7 e embebidos em cilíndro por resina autopolimerizável de poliestireno. Posteriormente, foram divididos aleatoriamente em seis grupos, sendo dois controles: GS (saliva, durante todo o experimento) e GP (PC, por seis horas, durante 14 dias) e quatro experimentais, que após a utilização diária do PC, foram submetidos à aplicação de gel antioxidante por 15, 30, 60 ou 120 minutos, respectivamente (GPA15, GPA30, GPA60 e GPA120). Imediatamente após o tratamento, os fragmentos foram condicionados com ácido fosfórico a 37% (Dentsply) e restaurados com sistema adesivo Adper Single Bond (3M-ESPE) e três incrementos horizontais de resina TPH (Dentsply). Finalizado o tratamento restaurador, os fragmentos foram preparados para o ensaio de microtração. Cortes seriados foram realizados em cada amostra para obtenção de duas fatias centralizadas de, aproximadamente, 1mm de espessura. Posteriormente, com auxílio de uma broca 1093FF, foi confeccionado em cada fatia, uma constrição, com área adesiva de, aproximadamente, 1mm2, em forma de ampulheta. Os testes de microtração foram realizados em máquina de ensaio EMIC, com velocidade de 0,5mm/min. A ANOVA e o Teste de Dunnet indicaram haver diferença estatisticamente significativa entre os grupos testados. Comparando-se o controle positivo (GS) com os demais, verificou-se que apenas o controle negativo (GP) diferiu estatisticamente. Quando se comparou o GP com os outros grupos, foi observada diferença estatística com o GS e o GPA120. Para comparação apenas entre os grupos experimentais (GPA15, GPA30, GPA60 e GPA120), foi aplicado o teste ANOVA e análise de regressão polinomial, que revelaram não haver diferença estatisticamente significativa para o fator tempo, de forma isolada. Foi detectada, através de observações em microscopia eletrônica de varredura, presença de pequenas bolhas no grupo clareado. Os padrões de fratura demonstraram maior número de falhas mistas, para todos os grupos testados. O gel de ascorbil a 3%, aplicado no tempo de duas horas, parece ser o mais indicado, para recuperar os valores de resistência de união ao esmalte clareado com peróxido de carbamida a 10% / Abstract: The purpose of this in vitro study was to evaluate the effect that elapsed time (15 min, 30 min, 1 hour e 2 hours) of a 3% ascorbil gel (AE) onto the bond strength to bovine enamel previously treated with carbamide peroxide at 10%, defining the fracture pattern through electronic scanning microscopy. Sixty bovine incisors were selected, cleaned, and stored in saline solution of timol at 0.1%. Sixty fragments of 25mm2 were obtained by the use of double-face diamond discs, in low rotation, under constant irrigation, perpendicularly to buccal surfaces. The fragments were relieved with a thin layer of wax n° 7 and steep in a cylinder by a self-curing polyester resin. Afterwards, they were random divided into six groups according to the type of treatment to be employed (GS- Positive Control- Saliva, during experiment; GP- Negative Control- PC, 14 days/6hours, GPA15- PC, 14days/6hours + AE, 15 min; GPA30- PC, 14days/6hours + AE, 30 min; GPA60-PC, 14days/6hours + AE, 1 hour; GPA120- PC, 14days/6hours + AE, 2 hours). After treatments, the groups were etched with fosforic acid 35% (Dentsply) and restored with adhesive system Adaper Single Bond (3M-ESPE) and three horizontal increments of resin TPH (Dentsply). Concluded the restorative treatment, the fragments were immediately prepared for microtensile procedure. Serial cuts were performed in each sample to obtain two centralized slices 1mm thick. Afterwards, using a 1093 FF drill, an hourglass was done in each slice, with adhesive area of approximately 1mm2. The microtensile tests were performed in an mechanical test machine, at 0.5 mm/min speed. ANOVA and Dunnett test indicated that there was statistical difference between groups tested. When compared positive control group (GS) with the other groups, it was observed that only the negative control group (GP) was statistically different. These results were confirmed, when the negative control group was compared with others, in which it was observed statistic diference to GS and GPA120. When the experimental groups were compared though regressive polinominal analise it was not found statistical difference only to the time factor. On Electronic Scanning Microscopy observations, were detected the presence of bubbles of the bleached group. The fracture standards demonstrated higher number of mixed failures to all the groups. The 3% ascorbil gel (AE) used for two hours seems to be the most recommended to reverse the strength to bleached enamel with carbamide peroxide 10% / Mestrado / Dentística / Mestre em Clínica Odontológica
13

Analise da união e dos tecidos dentais (esmalte/dentina) adjacentes as restaurações com sistemas adesivos contendo fluoreto apos desafios cariogenicos in situ e in vitro / Analysis of adhesion and mineralized dental tissues (enamel/dentin) around restorations with fluoride-containing adhesive systems after cariogenic challenge in situ and in vitro

Pinto, Cristiane Franco 15 August 2018 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T12:58:19Z (GMT). No. of bitstreams: 1 Pinto_CristianeFranco_D.pdf: 8181087 bytes, checksum: 41321386cc6d99055932efad6dad9919 (MD5) Previous issue date: 2010 / Resumo: O objetivo deste estudo foi avaliar sistemas adesivos, tecidos dentais adjacentes (esmalte ou dentina) às restaurações e a união formada entre os adesivos e as estruturas dentais frente aos desafios cariogênicos in situ e in vitro. Para o estudo foram utilizados dentes bovinos e blocos dos tecidos dentais (esmalte e dentina) que foram restaurados com dois sistemas adesivos e resina composta. No estudo in situ; 11 voluntários utilizaram dispositivos palatinos contendo 2 amostras do grupo controle (substrato hígido sem preparo cavitário) de esmalte e dentina, e 6 amostras restauradas com os sistemas adesivos Clearfil Protect Bond (PB) ou One-Up Bond F Plus (OP) (em fases distintas) e com o compósito Filtek Z350. O desafio cariogênico consistiu de 2 fases (cada fase com um adesivo), sendo cada fase de 14 dias com intervalo de 10 dias entre elas. Os voluntários utilizaram solução de sacarose a 20%, 8X/dia e dentifrício fluoretado 3X/dia. Após cada etapa, o biofilme dental formado foi coletado e analisado. As amostras foram analisadas através de Microscopia de Luz Polarizada (MLP) e Microdureza Knoop para observação da extensão da lesão de cárie. Para o estudo in vitro foi realizado o preparo dos substratos e foram restaurados em esmalte e em dentina seguindo os grupos experimentais: 1-adesivo PB sem desafio cariogênico (DC); 2- adesivo PB com DC; 3- adesivo OP sem DC; 4- adesivo OP com DC. A partir dos blocos dentais restaurados foram obtidos espécimes para o ensaio de resistência da união com formato de paralelepípedos (palitos) e fatias para análise da interface da união em Microscopia Eletrônica de Transmissão (MET). Os espécimes (palitos ou fatias) foram submetidos à ciclagem de pH durante 8 dias. O resultado do ensaio de microdureza em esmalte e dentina mostrou maiores valores para PB nas profundidades mais superficiais e as imagens de MLP mostraram uma menor extensão da área de desmineralização para o adesivo PB que para o adesivo OP. Na análise bacteriológica, o adesivo PB levou a menor quantidade de colônias de Streptococcus totais e do grupo mutans em esmalte. A resistência de união não foi afetada pela ciclagem de pH e foi semelhante em esmalte para ambos adesivos, entretanto, em dentina, o adesivo PB apresentou maior resistência de união que o adesivo OP. Os adesivos produziram hibridização nos tecidos dentais, sem formações de fendas na interface de união. Concluiu-se que o adesivo PB produziu menor extensão de desmineralização dos substratos dentais após o desafio cariogênico e maior microdureza Knoop nas profundidades mais superficiais. Em algumas condições deste estudo, o adesivo PB reduziu a formações de colônias bacterianas. Embora a união formada pelos adesivos em esmalte foi semelhante, o adesivo PB mostrou maior resistência de união em dentina. / Abstract: The aim of this study was to evaluate adhesive systems, mineralized dental tissues (enamel and dentin) around restorations and the bonding formed by adhesives and dental structures in conditions of cariogenic challenge in situ and in vitro. This study used dental blocks (enamel/ dentin) from bovine teeth, which were restored with adhesive systems and a resin composite. For the in situ study: volunteers (n=11) wore intra-oral appliance containing 2 dental fragments without restoration (enamel or dentin) and six dental blocks with restorations made with self-etching primers Clearfil Protect Bond (PB) or One-up Bond F Plus (OP) (in two phases) and the Filtek Z350 composite: The cariogênico challenge was performed in two phases of 14 days (each phase with one adhesive). The volunteers dropped 20% sucrose solution 8x/day and used fluoridated dentifrice 3x/day. After each phase, the biofilm was collected and analyzed. The samples were analyzed by cross-sectional microhardness and polarized light microscopy (PLM) to determine the demineralization depth. For the in vitro study, bovine were prepared and bonded in enamel and dentine with Clearfil Protect Bond (PB) or One-Up Bond F Plus (OP) and restored with Filtek Z-350 composite resin, according to the groups: 1- PB without CC; 2- PB with CC; 3- OP without CC; 4- OP with CC. Restored teeth were sectioned in order to obtain sticks for microtensile bond strength or slabs for transmission electron microscopy. The specimens were submitted to pHcycling, which consisted of DE (8h/day) and RE (16h/day) cycles at 37ºC during days. Microhardness analysis showed that the enamel and dentin around restorations PB had higher values in superficial depths, and the PLM showed that PB resulted in lower demineralization depth than OP. The biofilm investigation indicated that PB produced lower number of bacterial colony of Streptococcus totais and mutans in enamel. The results showed that the pH-cycling regimen did not affect the bond strength to enamel or dentin for both adhesives; however, the bond strength to dentin was higher for PB. The adhesives produced hybridization and no gaps formation in both dental tissues. In conclusion, PB adhesive may result in lower enamel demineralization around restoration and higher microhardness in superficial depths. In some conditions, PB adhesive reduced the number of bacterial colony. Although the adhesives in enamel formed similar bonded interfaces, PB produced higher bond strength to dentin than OP. / Doutorado / Dentística / Doutor em Clínica Odontológica
14

Resistência da união de cimentos resinosos autoadesivos e autocondicionantes em esmalte e dentina / Bond strenght evaluation of self-adhesive and self-etching resin cement on enamel and dentin

Lacerda, Renata Fernandes de Souza, 1985- 22 August 2018 (has links)
Orientador: Mário Fernando de Góes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T18:56:44Z (GMT). No. of bitstreams: 1 Lacerda_RenataFernandesdeSouza_M.pdf: 2496553 bytes, checksum: 8b83acbb5a024d77dc12f2bb97771b5f (MD5) Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar a resistência da união de cimentos resinosos autoadesivos e autocondicionantes aplicados sobre a superfície da dentina e esmalte. Foram utilizados 36 terceiros molares. Em metade destes dentes tiveram a face oclusal removida e a dentina exposta. Na outra metade, as coroas foram seccionadas longitudinalmente para obter hemi-secções de esmalte. A seguir ambas as amostras foram planificadas usando lixas de carbeto de silício de granulação #600. Restaurações de resina composta indireta (Sinfony), com 2 mm de espessura, foram confeccionadas em dois formatos circulares, de 10 e 7mm de diâmetro e jateadas com óxido de alumínio para serem cimentadas sobre a superfície da dentina e esmalte, respectivamente. Os dentes preparados foram divididos em 4 grupos para cada substrato (esmalte e dentina): Grupo I - RelyX Unicem 2 - cimento autoadesivo, Grupo II - Maxcem Elite - cimento autoadesivo, Grupo III - RelyX Unicem 2 associado ao sistema adesivo Scothbond Universal - cimento autocondicionante, Grupo IV - Multilink Automix - cimento autocondicionante. Após a cimentação os conjuntos dente/restauração foram armazenados em água destilada à 37°C por 24 horas e seccionados em formato de palitos com área transversal quadrada de 0.8±0.2mm2 para o ensaio de tração, utilizando uma máquina de ensaios universal operando com célula de carga de 50kgf e à velocidade de 1mm/min. O tipo de fratura foi observado e classificado em microscopia eletrônica de varredura (MEV). Os dados foram submetidos à análise de variância e o teste de Tukey para comparação entre os grupos (p<0,05). Os resultados da resistência de união revelaram que dentre os cimentos autoadesivos, o cimento RelyX Unicem 2 (13±4,2 e 14,3±6,8) apresentou valor significantemente maior comparado ao Maxcem (12,2±5,9 e 5,4±3,1) quando avaliado sobre a dentina. Na condição autocondicionante o cimento RelyX Unicem 2 associado ao adesivo Scothbond Universal (29,7±12,1 e 50,6±18,2) apresentou valor estatisticamente superior ao valor apresentado pelo Multilink Automix (20,5±10,4 e 20,7±10,5) para o esmalte e dentina. Na condição autocondicionante a resistência de união foi superior estatisticamente à condição autoadesiva. As análises dos padrões de fratura em MEV no substrato dentinário mostraram predominância de fraturas coesivas em cimento para a maioria dos grupos, exceto para o grupo Maxcem, que apresentou predominância de fraturas mistas (coesivas no material e coesiva na smear layer). No esmalte houve predominância de fraturas coesivas no cimento para os grupos RelyX Unicem 2, RelyX Unicem 2 associado ao sistema adesivo Scothbond Universal e Maxcem Elite, enquanto que para o Multilink Automix houve predominância de fraturas mistas (adesiva e coesiva em cimento) / Abstract: The aim of this study was to evaluate the bond strength of self-etching and self-adhesive resin cements applied on the surface of the enamel and dentin. We used 36 third molars. Half of these teeth have the occlusal face removed to expose dentin surface. The remainder teeth were longitudinally sectioned to obtain hemi-sections of enamel. All surface of the teeth were flattened using silicon carbide sandpaper granulation #600. Circular matrix shapes (10 and 7mm in diameter) were prepared to fabricate an indirect composite resin restorations (Sinfony) with 2 mm thick). The surface of the restoration was air-abrasioned using aluminum oxide to be cemented onto the dentin and enamel surfaces, following the manufacturing recommendations. The prepared teeth were divided into 4 groups for each substrate [enamel and dentin]: Group I - RelyX Unicem 2 - self-adhesive cement; Group II - Maxcem Elite - Self-adhesive cement; Group III - Multilink Automix - self-etching cement; Group IV - RelyX Unicem 2 associated with adhesive system Scothbond Universal - self-etching cement. After cementing sets tooth / restoration were stored in distilled water at 37 ° C for 24 hours and sectioned shaped sticks with square area 0.8 ± 0.2mm2 for the tensile test using a universal testing machine. The fracture mode was observed and classified by SEM (scanning electron microscopy). The results were submitted to ANOVA and Tukey's test for comparison between groups (p<0.05). The results in enamel and dentin were, respectively in MPa: self-adhesive cement RelyX Unicem 2 (13,0±4.2 and 14.3±6.8) and Maxcem Elite (12.2 ± 5.9 and 5.4±3.1); self-etching cement - RelyX Unicem 2 associated with adhesive system Scothbond Universal (29.7±12.1 and 50.6±18.2); Multilink Automix(20.5±10.4 and 20.7±10.5). The bond strength of the self-etching cements showed statistical differences compared with self-adhesive cements in both enamel and dentin tissues. The Bond strength values produced by RelyX Unicem 2 associated with adhesive system Scothbond Universal was significantly higher than all other groups in enamel and dentin. The Self-adhesive cement Rely X Unicem 2 showed statistical difference in bond strength compared with MaxCem Elite in dentin. The fracture patterns showed predominance of cohesive fractures cement for most group, in dentin, except for group Maxcem, which showed a predominance of mixed fracture (cohesive in material and cohesive in the smear layer). In enamel predominated cohesive fractures in the cement for groups RelyX Unicem 2, RelyX Unicem 2 associated with the adhesive system Scothbond Universal and Maxcem Elite, while for Multilink Automix fractures predominated mixed (adhesive and cohesive in cement) / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
15

Estudo do comportamento da resina base na formulação de compósitos de politetrafluoretileno com bronze / Study of the behavior of the base resin in the formulation of polytetrafluoroethylene composites with bronze

Bento, Ronaldo Euzébio 19 August 2018 (has links)
Orientador: João Sinézio de Carvalho Campos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-19T08:39:45Z (GMT). No. of bitstreams: 1 Bento_RonaldoEuzebio_M.pdf: 1080016 bytes, checksum: c783e50a51346a7d89eb82f52976eb49 (MD5) Previous issue date: 2011 / Resumo: Esse trabalho concentra os estudos na investigação das propriedades de resistência a tração e alongamento do compósito de Politetrafluoretileno (PTFE) com 60% de bronze após a substituição do tipo de PTFE utilizado na formulação desse compósito. Atualmente esse compósito utiliza PTFE convencional na formulação e o objetivo é alterar para PTFE modificado. A motivação para essa alteração deveu-se ao fato que o PTFE convencional apresenta disponibilidade limitada dificultando o desenvolvimento dos segmentos que utilizam os compósitos de PTFE com 60% de bronze. A escolha do PTFE modificado para a substituição do PTFE convencional na formulação do compósito de PTFE com 60% de bronze deveu-se ao fato que polímero puro de PTFE modificado apresenta propriedades mecânicas e químicas superiores ao polímero puro de PTFE convencional, além de não apresentar limitações de disponibilidade, possibilitando a continuidade do crescimento dos segmentos industriais. A escolha do compósito de PTFE com 60% de bronze deveu-se ao fato que essa formulação é a mais empregada no segmento automobilístico para a fabricação de anéis para amortecedores e retentores. Após a substituição da resina de PTFE, os resultados demonstraram que o compósito de PTFE modificado com 60% de bronze apresentou propriedades inferiores ao compósito fabricado com PTFE convencional. A queda dessas propriedades pode estar relacionada com possíveis micros fissuras na estrutura do compósito em virtude de ar preso durante o processo de fabricação / Abstract: This work focuses on research studies of the properties of tensile strength and elongation of the composite of Polytetrafluoroethylene (PTFE) with 60% bronze after replacing the type of PTFE used in the formulation of this compound. Currently, this composite uses conventional PTFE in the formulation and the objective is to change to modified PTFE. The motivation for this change was due to the fact that the conventional PTFE has limited availability hindering the development of the segments that use the PTFE composite with 60% bronze. The choice of PTFE modified PTFE to replace the conventional formulation of the composite with 60% PTFE bronze was due to the fact that pure polymer modified PTFE has superior mechanical and chemical properties of the pure polymer PTFE conventional, and not present availability limitations, enabling the continued growth of industries. The choice of the composite with 60% PTFE bronze due to the fact that this formulation is the most used in the automotive sector for the manufacture of rings and seals for shock absorbers / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
16

Studium vlastností cementových kompozitů s rozptýlenou výztuží z anorganických vláken / Study of properties of cementitious composites with fiber reinforcement from inorganic fibers

Gottwaldová, Aneta January 2019 (has links)
Diploma thesis deals with study of properties of cementious composites with fiber reinforcement from glass and basalt inorganic fibers. Diploma thesis includes a theoretical and experimental part. The theoretical part deals with information about glass and basalt fibers, their durability and usage. In the experimental part we monitored properfies of cement composites with basalt and glass fibers. Fibers were exposed to an aggressive environment. The properties of composites with reference fibers were compared with composites with fibers affacted by the aggressive environment. The properties of composites were examined after 28 and 90 days. We monitored compresive strenght, bending tensile strenght, tensile strenght, surface layer strenght and SEM.
17

Influencia dos modos de ativação no grau de conversão, resitencia e morfologia da interface de união de sistemas de cimentação e adesivos / Effect of different activation modes on the degree of conversion, tensile bond strength and interfacial morphology of dual-cured cementing systems used in indirect composite restorations

Arrais, Cesar Augusto Galvão 14 December 2006 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ondontologia de Piracicaba / Made available in DSpace on 2018-08-08T01:52:29Z (GMT). No. of bitstreams: 1 Arrais_CesarAugustoGalvao_D.pdf: 8768801 bytes, checksum: bf5f97c936134b9476bb797b23d446d6 (MD5) Previous issue date: 2006 / Resumo: A não fotoativação do sistema adesivo previamente à aplicação do cimento resinoso tem sido proposta quando sistemas de cimentação de dupla ativação (SCDA - sistemas adesivos de dupla ativação / cimentos resinosos de dupla ativação) são utilizados. Entretanto, existe uma carência de relatos científicos a respeito da efetividade dos SCDA. Os objetivos deste estudo foram: 1- avaliar a resistência de união (RU) e a morfologia da interface de união de restaurações indiretas de compósito através da utilização da microscopia confocal laser quando os sistemas adesivos de dupla ativação foram ou não fotoativados previamente à aplicação dos cimentos resinosos; 2- analisar o grau de conversão (GC), através da Espectroscopia Infravermelha Transformada de Fourier (FTIR), e a RU de SCDAs quando a fotoativação não foi realizada ou atenuada pela presença da restauração indireta; 3- avaliar o GC e resistência coesiva de sistemas de união quando utilizados diferentes unidades de fotoativação (LEDs e de luz halógena). A RU e resistência coesiva foram avaliadas através do ensaio de microtração. Para a análise em microscopia confocal laser, diferentes corantes foram incorporados nos SCDAs previamente à sua aplicação. Para a análise do GC, os SCDAs foram aplicados na superfície do diamante da unidade de reflectância total atenuada acoplada ao espectrômetro infravermelho. O GC dos sistemas de união não relacionados aos SCDAs foi obtido utilizando-se filmes de resina adesiva. Os resultados demonstraram que a não fotoativação do sistema adesivo de dupla ativação previamente à cimentação não afetou a RU, e que os valores foram até superiores para um SCDA de 4ª geração quando o agente de união não foi fotoativado. A análise em microscopia confocal laser exibiu variação nas características morfológicas da interface de união, variando de acordo com o SCDA utilizado e com o modo de ativação de ambos componentes (sistema adesivo e cimento resinoso). Para alguns SCDAs, o GC foi reduzido pela presença do disco de compósito posicionado entre o SCDA e a ponta da unidade fotoativadora. A não fotoativação dos SCDAs resultou em GC inferiores aos obtidos com exposição direta da luz. A não fotoativação da maioria dos SCDAs também resultou em valores inferiores de RU, exceto quando um sistema de 4ª geração foi utilizado. A utilização de LED resultou em GC inferior ao obtido quando a luz halógena foi utilizada mas não afetou a resistência coesiva dos sistemas adesivos avaliados. Pode-se concluir que a não fotoativação dos sistemas adesivos é uma alternativa aceitável durante a cimentação de restaurações indiretas, porém os SCDAs necessitam de luz fotoativadora para garantir adequada RU. A utilização de LEDs pode comprometer o GC dos sistemas adesivos / Abstract: The lack of light-activation of dual-cured bonding agents before the resin cement application has been an alternative technique of cementing indirect restorations when dual-cured cementing systems are used (DCS ¿ dual-cured bonding agents / dual-cured resin cements). However, few reports exist regarding the effectiveness of DCS when dual-cured bonding agents are left in the uncured state before the seating of the indirect restoration. Therefore, the aims of this study were: 1- to evaluate the microtensile bond strength (MTBS) and micromorphology of the adhesive interface of indirect restorations by confocal laser microscopy (CLSM) when the dual-cured bonding agents were left in the uncured state; 2- to analyze the degree of conversion (DC) by Fourier Transformed Infrared Spectroscopy and the bond strength of indirect restorations when DCSs were applied to the tooth and light activated or allowed to self-cure; 3- to evaluate the DC and ultimate tensile strength (UTS) of bonding agents light-activated with light curing units (LEDs and halogen light). The MTBS and UTS were analyzed using microtensile bond strength test. Different dyes were incorporated to the DCSs before they were applied to teeth for the CSLM analysis. For the DC analysis, the DSCs were applied to the diamond surface of attenuated total reflectance unit of the infrared device. The DC of the bonding agents related to the study evaluating the effectiveness of light-curing units was obtained from thin resin adhesive films. The results demonstrated that the MTBS was not affected, and the values were even higher for one 4th generation DCS, when the dual-bonding agents were left in the uncured state before the resin cement application. The CLSM analysis exhibited some variation in the micromorphological features, which depended on the DCSs and on the curing modes of bonding agents and resin cements. Some DCSs showed lower DC when pre-cured resin composite discs were used. The self-cured groups exhibited lower MTBS than the light-activated ones, except for one 4th generation DCS. The LED promoted lower DC in all bonding agents than did the halogen light. No difference in UTS was observed when LED was used. It was concluded that leaving the dual-cured bonding agent in the uncured state before seating the indirect restoration may be a reliable technique to ensure adequate MTBS, but most DCSs should be light-activated after seating the indirect restoration to provide optimal bond strength. Some LEDs can compromise the DC of adhesive systems / Doutorado / Dentística / Doutor em Clínica Odontológica
18

Cimentos resinosos convencionais e autoadesivos = caracterização das partículas de carga, ultramorfologia e resistência da união resina-dentina / Conventional and self-adhesive resin cements : filler particles characterization, ultramicromorphology and dentin-resin bond strenght

Aguiar, Thaiane Rodrigues 18 August 2018 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T10:52:55Z (GMT). No. of bitstreams: 1 Aguiar_ThaianeRodrigues_D.pdf: 24572936 bytes, checksum: 8141f58fcbce6835d1091f52127552a7 (MD5) Previous issue date: 2011 / Resumo: O emprego dos cimentos resinosos na fixação de peças protéticas têm sido avaliado em muitos estudos, entretanto, trabalhos que simulem os desafios presentes na cavidade bucal e o comportamento a longo prazo dos cimentos resinosos autoadesivos ainda são escassos na literatura. Diante disso, o presente estudo teve como objetivo: 1) verificar a composição inorgânica das partículas de carga e caracterizá-las quanto ao tipo e morfologia; 2) analisar a ultramorfologia da interface de união dentina-cimento resinoso através da microscopia confocal por varredura a laser e da microscopia eletrônica de varredura (MEV); 3) avaliar o efeito do armazenamento por 1 ano ou da ciclagem mecânica (50.000 ciclos) na resistência de união dentina-cimento resinoso. Quatro cimentos resinosos foram avaliados: dois autoadesivos (RelyX Unicem, 3M ESPE e Clearfil SA Luting, Kuraray Medical Inc.) e dois convencionais (RelyX ARC/Adper Scotchbond Multi-Purpose Plus, 3M ESPE e Clearfil Esthetic Cement/Clearfil DC Bond, Kuraray Medical Inc.). Para analisar os principais componentes inorgânicos e avaliar as características das partículas de carga, o conteúdo orgânico dos cimentos resinosos foi removido por solventes orgânicos e as amostras analisadas em MEV/EDX (Espectroscopia de energia dispersiva por raios-X). Terceiros molares humanos foram utilizados na avaliação da ultramorfologia da interface dentina-cimento resinoso e no ensaio de resistência de união à dentina. Na análise da ultramorfologia da área de união, corantes (fluoresceína e rodamina) foram previamente adicionados aos materiais estudados para possibilitar a obtenção das imagens. Para o ensaio de resistência de união, discos de resina composta indireta foram confeccionados visando simular as restaurações indiretas. Após a cimentação, os dentes restaurados foram submetidos a três tratamentos e ao ensaio de microtração: 1- espécimes testados após 24 h (grupo controle); 2- ciclagem mecânica e em seguida testados; 3- armazenados em saliva artificial por 1 ano na forma de "palitos" e testados. Os dados obtidos a partir do ensaio de resistência de união foram analisados estatisticamente (ANOVA e teste Tukey, p<0,05). Nos outros dois estudos, a análise descritiva dos dados obtidos a partir das imagens microscópicas foi realizada. Na avaliação MEV/EDX notou-se elevado conteúdo de silício em todos os materiais. O cimento RelyX ARC apresentou partículas de carga esféricas e irregulares, enquanto os outros materiais demonstraram partículas com formato irregular. Nas fotomicrografias, a hibridização dentinária somente foi observada para os sistemas de cimentação convencional. No ensaio de resistência de união, os tratamentos não influenciaram a resistência de união dos cimentos resinosos à dentina. Os cimentos autoadesivos apresentaram médias de resistência de união significantemente superiores aos chamados convencionais. Embora os materiais avaliados apresentem partículas de carga com distintas composições inorgânicas e interagem com a dentina através de diferentes mecanismos, os tratamentos de envelhecimentos propostos não reduziram a resistência de união à dentina, quando comparados ao grupo controle. Os cimentos autoadesivos não formam camada híbrida na dentina intertubular, nem tags de resina nos túbulos dentinários, entretanto, apresentam partículas de carga com maior tamanho e demonstraram os maiores valores médios de resistência de união à dentina entre os cimentos estudados / Abstract: Resin luting materials to fixed prosthetic restorations have been evaluated in many studies, however, little is known about self-adhesive resin cements, mainly involving long-term durability and when these materials have been submitted to challenges of oral environment. Thus, the purpose of this study was: 1- to verify the filler particles components and to characterize them according to type and morphology; 2- to analyze the ultramorphology of the dentin-resin interfaces using confocal laser scanning microscopy and scanning electron microscopy (SEM) and 3- to evaluate the effect of the storage for 1 year or the mechanical cycling (50.000 cycles) on bond strength of resin cements to dentin. Four resin cements were used in this study: two self-adhesive resin cements (RelyX Unicem, 3M ESPE and Clearfil SA Luting, Kuraray Medical Inc.) and two conventional resin cements (RelyX ARC/Adper Scotchbond Multi- Purpose Plus, 3M ESPE and Clearfil Esthetic Cement/Clearfil DC Bond, Kuraray Medical Inc.). For indentifying the main inorganic components and to evaluate the filler particles characteristics, the organic phase of resin cements was removed using organic solvents and the sample was analyzed by SEM/EDX (Energy-dispersive X-ray spectroscopy). Human third molars were used for micromorphology analysis of resin-dentin interfaces and microtensile bond strength test. For micromorphology analyses of resin-dentin interfaces, two fluorescent dyes (fluorescein and rhodamine B) were incorporated into the materials previously. For microtensile bond strength, pre-polymerized resin discs were prepared to simulate indirect restorations. After bonding procedures, the restored teeth were submitted to three treatments: 1- control group (tested 24 h after specimen preparation); 2- tested after mechanical cycling; 3- beams were storage for one year in artificial saliva and tested. Bond strength data were statistically analyzed by two-way ANOVA and Tukey test (?<0.05). Qualitative analysis was performed for two other studies using microscopic images. For SEM/EDX measurements, high amount of silicon was identified for all cements. The resin cement RelyX ARC showed spherical and irregular particles, while other cements presented irregular shape fillers. Hybrid layer formation was observed only for conventional resin cements in micromorphology analyses. For microtensile test, the treatments did not reduce the bond strength between dentin-resin cement. Self-adhesive resin cements provide significantly higher bond strength than those conventional materials. Despite the resin cements showed filler particles with differences in the inorganic composition and different bonding mechanisms, the mechanical cycling and storage for one year did not affect the bond strength to dentin when it was compared to control group. The self-adhesive resin cements showed no hybrid layer formation in intertubular dentin and nor resin tags in the dentinal tubules were detected. However, these materials showed the biggest filler particles and higher bond strength to dentin than conventional resin cements studied / Doutorado / Dentística / Doutor em Clínica Odontológica
19

INFLUÊNCIA DA APLICAÇÃO ULTRASSÔNICA EM DIFERENTES SISTEMAS ADESIVOS NA ADESÃO DE PINOS DE FIBRA DE VIDRO AO CANAL RADICULAR / Effect of ultrasonic application of different adhesive systems on the adhesion of glass fiber posts to root canal

Escobar, Carolina Gealh Navarro 18 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:06Z (GMT). No. of bitstreams: 1 Carolina Navarro Escobar.pdf: 2962199 bytes, checksum: b363e18fe311073f074dad7842063d6b (MD5) Previous issue date: 2016-02-18 / The aim of this study was evaluate the influence of the aplication mode of adhesive systems on the push-out bond strenght (POBS), silver nitrate uptake (SNU) and in situ degree of conversion (ISDC) on the hibrid layer after cementation luted posts.The roots of 66 human premolars were prepared and divided in six groups (n=11), according to the following combination: application mode (manual passive, manual active and ultrassonic vibration) and etch and rinse and self-etch adhesive systems (Adper Single Bond 2 and Single Bond Universal). The posts were cemented in accordance with the manufacturer’s instructions of each cementation system. After one week of water storage, the roots were seccioned transversely into six slabs and were tasted in POBS (0.5mm/min). Two roots for group were data immersed in 50% silver nitrate, photo-developed and analyzed by SEM to measure the SNU. Two roots for group were evaluated by micro-Raman spectroscopy to measure ISDC. The data were analyzed by 3-way repeated measures ANOVA and Tukey´s tests (5%). With the results obtained, it was observed: bond strength increased with the use of active application (manual and ultrasonic) of the adhesive. Using adhesive system Adper Single Bond the nitrate leakage values increase but with ultrasound prototype the nitrate leakage values reduce in relation active application. In ISDC a significant increase in the cervical and middle thirds with active application was observed and all thirds using ultrasound prototype, the passive application using Single Bond Universal adhesive showed worse results. / O objetivo deste estudo foi avaliar o efeito do modo de aplicação de sistemas adesivos nos valores de resistência de união (RU), nanoinfiltração (NI) e grau de conversão (GC) da camada híbrida após a cimentação dos pinos no interior do conduto radicular. Canais de 66 pré-molares unirradiculares foram tratados endodônticamente, e foram aleatoriamente divididos em seis grupos (n=11) de acordo com a combinação da técnica de aplicação adesiva (manual passiva, manual ativa e aplicação vibratória com um dispositivo ultrassônico) e dos sistemas adesivos com seus respectivos cimentos resinosos (Sistema Adesivo Adper Single Bond 2 com RelyX ARC e Single Bond Universal e RelyX Ultimate [3M ESPE]). Após uma semana dos procedimentos de cimentação, cada raiz foi seccionada transversalmente em seis discos com 1 mm de espessura cada, e os terços coronário (TC), médio (TM) e apical (TA) do canal radicular identificados. Sete raízes por grupo (n=7) foram submetidas ao teste de push-out para avaliação da RU, a uma velocidade de 0,5 mm/min. Duas raízes por grupo (n=2) foram imersas em 50% de nitrato de prata, e após revelação, foram analisadas por MEV para avaliação da NI, e os corpos de prova das duas raízes restantes de cada grupo (n=2) foram avaliadas por espectroscopia de micro-Raman para medir GC. Os dados de RU, NI e GC foram analisados por análise de variância de 3 fatores de medidas repetidas (terço radicular) e teste de Tukey (5%). Com os resultados obtidos, foi observado: aumento de resistência de união com a utilização da aplicação ativa (manual e utrassônica) do adesivo. Maiores valores de infiltração de nitrato utilizando o sistema adesivo Adper Single Bond, uma redução dos valores de infiltração de nitrato utilizando o protótipo de ultrassom em relação aplicação ativa. No teste de grau de conversão foi observado um aumento significativo de GC nos terços cervical e médio com a utilização da aplicação ativa e em todos os terços utilizando o protótipo de ultrassom, na aplicação passiva utilizando o adesivo Single Bond Universal foram obtidos os piores resultados.
20

Desempenho de sistemas adesivos autocondicionantes com diferentes pH

Almeida, Érica de Andrade 29 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-27T11:49:47Z No. of bitstreams: 1 ericadeandradealmeida.pdf: 3463747 bytes, checksum: 5ac7183d712eff15259d8a21bef582ef (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-28T13:03:40Z (GMT) No. of bitstreams: 1 ericadeandradealmeida.pdf: 3463747 bytes, checksum: 5ac7183d712eff15259d8a21bef582ef (MD5) / Made available in DSpace on 2016-06-28T13:03:40Z (GMT). No. of bitstreams: 1 ericadeandradealmeida.pdf: 3463747 bytes, checksum: 5ac7183d712eff15259d8a21bef582ef (MD5) Previous issue date: 2012-03-29 / A hibridização dos tecidos dentais duros pode ser realizada através de duas abordagens; a convencional ou a autocondicionante. A abordagem autocondicionante propicia menor número de passos clínicos e menos sensibilidade na técnica operatória.O objetivo deste estudo foi analisar a resistência da união à microtração (μTBS) imediata e após o envelhecimento com termociclos dos sistemas adesivos autocondicionantes de um passo e dois passos, sendo o grupo controle tratado com sistema adesivo convencional. A superfície oclusal de 24 terceiros molares foi removida, posteriormente a raiz foi seccionada para obtenção de um disco com 5mm de espessura, com a superfície em dentina média. As superfícies foram padronizadas e distribuídas aleatoriamente em quatro grupos de acordo com o sistema adesivo testado em: G1-Single Bond 2, G2- Clearfil SE Bond, G3- Adper Easy One e G4- Clearfil TriS. Sobre as superfícies tratadas foram confeccionados blocos de resina composta, Filtek Z350 XT, cor A2 corpo. As amostras foram seccionadas produzindo palitos com aproximadamente 1mm2 de área transversal. Cada grupo foi dividido novamente em dois, sendo eles: amostras armazenadas em água deionizada por 24h ou envelhecidas (1000 ciclos). Os corpos de prova foram submetidos ao teste de microtração e os valores obtidos foram analisados estatisticamente pelo teste ANOVA two-way e pelo teste de comparação múltipla Tukey (p<0,05). A classificação dos tipos de fratura foi realizada em MEV. Os maiores valores foram apresentados pelos grupos: G1, G5 e, G2, G6, não havendo diferença estatística entre si. Os menores valores médios foram dos grupos G4 e G8 apresentando diferença estatística com os grupos tratados com o adesivo convencional. A partir da análise das fraturas pode ser observado a redução da fratura Tipo I (entre camada híbrida e a camada de adesivo) dos grupos submetidos ao teste de microtração após 24h em relação aos seus homólogos submetidos ao envelhecimento por termociclos. Conclui-se que o melhor desempenho no teste de microtração foi apresentado pelos adesivos convencional e autocondicionante dois passos. Não foi encontrada associação entre a resistência da união após 24 e envelhecimento. / The hybridization of dental hard tissues may be accomplished by both approaches, the etch rinse or the self-etching. The self-etching approach provides fewer steps and less sensitivity in clinical technique. The objective of this study was to analyze the microtensile bond strength (μTBS) immediately and after aging with thermocycling of adhesive systems in one step and two steps, considering the control group treated with conventional adhesive system. The occlusal surface of 24 third molars was removed, and then the root was cut to obtain a 5 mm thick disc, with the average dentin surface. The surfaces were standardized and distributed randomly into four groups according to the adhesive system tested on: G1-Single Bond 2, G2- Clearfil SE Bond, G3- Adper Easy One e G4- Clearfil TriS. About the treated surfaces were fabricated composite resin blocks, Filtek Z350 XT, blade A2 body. The samples were selected to produce sticks with approximately 1mm2 cross sectional area. Each group was divided again into two, namely: samples stored in deionized water and aged for 24 hours (1000 cycles). The specimens were submitted to microtensile testing and the values obtained were statistically analyzed by two-way ANOVA and the Tukey multiple comparison test (p <0.05). The classification of types of fracture was performed by SEM. The highest values were presented by groups: G1, G5, and G2, G6, with no statistical difference between them. The lowest values were performed by groups G4 and G8 presenting statistical difference in the groups treated with the conventional adhesive. From the analysis of the fractures were observed that fracture reduction type I (between hybrid layer and adhesive layer) of the groups submitted to microtensile testing after 24 hours compared to their counterparts submitted to aging by termocycling. It can be concluded that the best performance in microtensile test was made by conventional and self adhesive two steps. No association was found between the bond strength after 24 of aging.

Page generated in 0.0893 seconds