• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 107
  • 22
  • 15
  • 11
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 2
  • Tagged with
  • 426
  • 426
  • 169
  • 167
  • 84
  • 75
  • 64
  • 59
  • 52
  • 48
  • 48
  • 46
  • 46
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação da resistência de união em dentina de um adesivo de frasco único quando utilizado diferentes fontes de ativação

Kreidler, Martín Antúnez de Mayolo [UNESP] 14 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-14Bitstream added on 2014-06-13T20:51:31Z : No. of bitstreams: 1 kreidler_mam_me_arafo.pdf: 1061515 bytes, checksum: 8631de69ed2363b4ba75419b58ee0e3b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste estudo foi avaliar através do teste de microtração e da análise do padrão de fratura, o efeito da luz halógena e LED, na ativação de um adesivo de frasco único. Superfícies dentinárias planas foram criadas em 16 dentes terceiros molares hígidos. Os dentes foram aleatoriamente divididos em 4 grupos: Grupo G1 - Aparelho de luz halógena - KM-200R®; Grupo G2 - Aparelho LED - Ultraled®; Grupo G3 - Aparelho LED - UltraLume®LED5 e Grupo G4 - Aparelho LED - Biolux Single V®. O procedimento restaurador foi realizado utilizando o adesivo Single Bond® e a resina composta InTen-S®. Após as restaurações, os dentes foram armazenados em água destilada e estufa a 37ºC por 24h. A seguir, os mesmos foram cortados, resultando em espécimes com área de aproximadamente 1 mm2, que foram selecionados e submetidos ao teste de microtração para posterior observação do padrão de fratura no microscópio digital. Os resultados, submetidos a análise estatística mostram que o grupo G2 teve média de resistência de união significativamente menor que os demais grupos, que foram semelhantes entre si. Quanto ao tipo de fratura, houve diferença significativa entre os grupos G1 e G2 e entre os grupos G2 e G4. Entre os outros grupos não houve evidência de diferenças significativas. As falhas de união foram predominantemente do tipo adesivas. Conclui-se que os aparelhos LEDs de segunda e terceira geração utilizados nesta pesquisa podem ser utilizados como uma alternativa viável à luz halógena. / The purpose of this study was to evaluate the effect of halogen light and LED on dentin tensile bond strength and fracture mode analysis. Flat dentin surfaces were created on 16 intact human third molars. The teeth were randomly divided in 4 groups: Group G1 - halogen - KM -200R®; Group G2 - LED - Ultraled®; Group G3 - LED - UltraLume LED5® and Group G4 - LED - Biolux Single V®. The restoration procedure used Single Bond® adhesive and InTen-S® composite resin. The teeth were placed in distilled water and stored at 37ºC for 24 hours. Then, they were cut on serial sections to obtain 1 mm2 area. The samples were submitted to micro tensile test and after words, the fractures were analysed with a digital microscope. The statistical analysis showed that all in all groups, except Group G2, which had a significant smaller tensile bond strength ratio. The fracture mode analysis showed that there were significant difference when comparing groups G1 / G2, and G2 / G4. There is no evidence of relevant differences among the other groups. Adhesive fracture was the most common fracture mode. As a conclusion, second and third LED generation used in this research could be use as an alternative to the conventional halogen lamp. Keyword: Dentin-bonding agents; tensile strength.
42

Avaliação in vitro da resistência de união do cerômero ao sistema de cimentação adesiva, através do teste de micro-tração. Efeito de diferentes tratamentos de superfície

Faria, Ricardo Pinheiro de [UNESP] 26 November 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-11-26Bitstream added on 2014-06-13T20:12:02Z : No. of bitstreams: 1 faria_rp_me_arafo.pdf: 2571722 bytes, checksum: 03eaaed6baf6d35de160ebd73d353c6a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A proposta deste estudo foi avaliar in vitro a resistência de união do Cerômero Artglass (Heraeus/Kulzer) ao cimento resiniso RelyX (3M), através do teste de Micro-Tração. Os seguintes tratamentos de superfície foram investigados: microjateamento com óxido de alumínio (AO), Artglass Liquid (AL), Silano (S), ácido fluorídrico (HF) e ácido fosfórico (AF). Cinco espécimes cada qual consistindo de um par de cilindro (10x10 mm) foram confeccionados. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação sequencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: grupo 1 (AO/AGL), grupo 2(AO/AF), grupo 3 (AO/AF/S), grupo 4 (AO/HF) e grupo 5 (AO/HF/S). Os espécimes aos pares foram cimentados com um sistema adesivo dual e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 horas a 37ºC e, posteriormente, termociclados. Com auxílio de um disco de diamente perpendicular a superfície de união, palitos com 1 mm2 de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS800). Resultados foram: grupo 1(29,39+-5,13), grupo 2 (27,49 +- 5,32), grupo 3(29,49 +- 4,94), grupo 4(24,41 +- 2,67), e grupo 5 (22,19 +- 2,33). ANOVA e o Teste de Tukey foram aplicados com p<0,05. Não houve diferenças estatisticamente significante entre os grupo 1,2 e 3; 4 e 5; e 2 e 4. As forças de união foram significantemente maiores nos grupos 1 e 3 do que nos grupos 4 e 5; e no grupo 2 do que o grupo 5. Conclusões: Microjateamento com óxido de alumínio e Artglass Liquid foi um pré-tratamento de superfície efetivo; a sinalização pode melhorar a força de união promovida pelo microjateamento e condicionamento... . / The purpose of this study was to investigate the effect of surface treatments on microtensile interfacial bond strength of a composite Artglass (Kulzer) to resin cement RelyX (3M). Methods of surfaces roughening or preparation included microetching with aluminum oxide (AO), Artglass Liquid (AGL), Silane (S), hydrofluoric acid (HF), and fosforic acid (AF). Five specimens, each consisting of a pair of cylinders (10x10 mm) were fabricated. The bonding surfaces were finished with 600-grit silicon carbide paper. Specimen pairs were randomly assigned to one of five surface treatment groups: group 1 (AO/AGL), group 2 (AO/AF), group 3 (AO/AF/S), group 4 (AO/HF), and group 5 (AO/HF/S). Specimen pairs were cemented with a dual resin bonding and a dual cure resin cement, in accordance with the manufacturer's instructions. Specimens were light-cured, then thermocycled 500 times at between 5º C and 55º C. Using a diamond disk perpendicular to the bonding interface, sticks with 1.0 mm2 cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. Results: Means (n=20) and standard deviations of bond strengths (MPa) were: group 1 (29.39 +- 5.13), group 2(27.49 +- 5.32), group 3(29.49 +- 4.94), group 4 (24.41 +- 2.67), and group 5 (22.19 +- 2.33). Data were analyzed with ANOVA and Tukey Test at p<0.05. There were no significant statistical differences among the groups 1,2, and group 3; groups 4 and 5; and groups 2 and 4. Microtensile bond strengths were significantly higher in groups 1 and 3 than in groups 4 and 5; and in group 2 than in group 5. Conclusions: AO and AGL was an effective surface pretreatment; silanation may improve the bond provided by AO and etching with AF; and etching with HF is not recommended, as it decreases bond strength.
43

Avaliação da resistência adesiva e características da zircônia após diferentes tratamentos de superfície / Bond strength and surface characteristics evaluation of zirconia after different treatments

Fernandes Júnior, Virgílio Vilas Boas [UNESP] 01 September 2017 (has links)
Submitted by Virgílio Vilas Bôas Fernandes Júnior (virgiliovilas@hotmail.com) on 2017-10-25T17:19:32Z No. of bitstreams: 1 Tese FInal .pdf: 39214788 bytes, checksum: 9123d03a17e8efd22b18caf0276a31db (MD5) / Rejected by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br), reason: Solicitado pelo autor. on 2017-10-25T18:25:54Z (GMT) / Submitted by Virgílio Vilas Bôas Fernandes Júnior (virgiliovilas@hotmail.com) on 2017-10-25T19:32:12Z No. of bitstreams: 1 Tese Final pdf 3.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-10-30T17:58:25Z (GMT) No. of bitstreams: 1 fernandesjunior_vvb_dr_sjc.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) / Made available in DSpace on 2017-10-30T17:58:25Z (GMT). No. of bitstreams: 1 fernandesjunior_vvb_dr_sjc.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) Previous issue date: 2017-09-01 / O objetivo desse estudo in vitro foi avaliar a resistência adesiva, rugosidade superficial, ângulo de contato e o espectro infravermelho da zircônia, após diferentes tratamentos de superfície. Para isso, blocos (n=9) de zircônia Y-TZP (e.max ZirCad - Ivoclar, Schann, Liechtenstein) foram seccionados em 39 fatias (12 x 11x 3 mm) divididas em grupos de acordo com cada teste. Para resistência adesiva, 20 fatias foram divididos em: 2 grupos controle; JAT, jateamento com óxido de alumínio e sílica + primer (Monobond Plus - Ivoclar, Schann, Liechtenstein); HFP, condicionamento com ácido fluorídrico 10% + primer, e 3 experimentais: PL, plasma (Plasma Não Térmico de Superfície - modelo SAP); PLP, plasma + primer; HFPLP, ácido fluorídrico + plasma + primer. Cada fatia de zircônia foi cimentada (Multilink N - Ivoclair, Schann, Liechtenstein) a um bloco pré-polimerizado de resina composta. Após a cimentação os espécimes foram seccionados, e 48 palitos com área adesiva de 1 mm2 foram obtidos em cada grupo para o ensaio de microtração (μTBS). Quatro outras fatias foram submetidas à análise de rugosidade superficial e 12 fatias submetidas à análise do ângulo de contato, após os seguintes tratamentos de superfície: sem tratamento (AV), aplicação de ácido fluorídrico a 10% (AHF), aplicação de plasma (AP) e jateamento (AJ), sendo que para o ângulo de contato foram feitas medições imediatamente após o tratamento, após 12 e 24 horas. Os resultados foram submetidos à análise estatística Anova e teste de Tukey a 5% (p< 0,05). Os espectros das ligações químicas da superfície da zircônia foram determinados em 3 outras amostras após as seguintes condições: sem tratamento (AV), jateamento (JAT) e aplicação de ácido fluorídrico 10% seguido da aplicação do plasma (AHFP). Em termos de adesão, não houve diferença estatística significante entre os grupos JAT e HFPLP, porém esses 2 foram estatisticamente superiores ao grupos HFP, PL e PLP. O jateamento demonstrou aumentar significantemente a rugosidade superficial em relação aos demais grupos. O plasma demonstrou diminuir o ângulo de contato da superfície da zircônia imediatamente e ao longo de 48 horas. / The purpose of this in vito study was to evaluate zirconia bond strength, surface roughness, contact angle and to mesure infrared spectrum after different surface treatments. Y-TZP zirconium (e.max ZirCAD - Ivoclair, Schann, Liechtenstein) blocks (n=9) were sliced into 36 discs (12 x 11 x 3 mm) and divided (n=4) into surface treatment groups as following: two control groups: JAT, airborneparticle abrasion and HFP, 10% hydrofluoric acid etching + primer (Monobond Plus - Ivoclair, Schann, Liechtenstein)application ,and three experimental groups: PL, non-thermal plasma (Surface Non-Thermal Plasma SAP model) application; PLP non-thermal plasma + primer application, and HFPLP, 10% hydrofluoric acid etching + non-thermal plasma + primer application. Each zirconia disk was cemented (Multilink N - Ivoclair, Schann, Liechtenstein) to a pre-polymerized resin block (Filtek Z350 - 3M, St Paul, MN, USA). After cementation the specimens were sectioned and 48 sticks with adhesive area of 1 mm2 obtained from each group for micro-tensile testing (μTBS). Four discs were submitted to surface roughness analysis and 12 discs to contact angle analysis, after the following surface treatments: no treatment (AV), 10% hydrofluoric acid etching (AHF), non-thermal plasma application (AP); and airborne- particle abrasion (AJ). The results were submitted to ANOVA and Tukey's test (p < 0.05). Zirconia surface chemical bonds spectrum was determined in infrared spectroscopy for three specimens after the conditions: no treatment; airborne- particle abrasion and hydrofluoric acid etching + non-thermal plasma application. The results showed no statistically significant differences between the groups JAT and HFPLP, but these two groups were statistically superior to HFP, PL and PLP. Airborne- particle abrasion resulted in a significant increase of surface roughness compared to the other groups. Non-thermal plasma was shown to decrease the contact angle of the surface, within 48 hours.
44

Efeito da excitação ultrasônica na resistência máxima à tração e de união à dentina de cimentos de ionômero de vidro, após diferentes períodos de armazenamento /

Azevedo, Elcilaine Rizzato. January 2008 (has links)
Orientador: Angela Cristina Cilense Zuanon / Banca: Renata Cristiane da Silva / Banca: Josimeri Hebling da Costa / Resumo: Este estudo investigou o efeito da excitação ultra-sônica na resistência máxima à tração e de união à dentina de cimentos de ionômero de vidro (CIV), após 24 horas ou 30 dias de armazenamento em água destilada à 37ºC, por meio do teste de microtração. Os materiais utilizados foram o CIV de alta viscosidade Fuji IX GP, Ketac Molar e o modificado por resina, Vitremer. Foram confeccionados 12 corpos de prova para cada material, dos quais 6 formaram o grupo controle e 6 receberam tratamento com US, por 30 segundos. Para o experimento de resistência de união à dentina, trinta e seis terceiros molares foram divididos aleatoriamente entre os grupos experimentais já descritos. Em ambos os experimentos, após o período de armazenamento, os corpos de prova foram seccionados em espécimes com área adesiva média de 0,91mm2 (± 0,1) e 0,93 mm2 (± 0,09), respectivamente para o experimento de resistência à tração e de união. Os dados foram analisados pela análise de variância com a correção de Welch (p<0,001) e teste de Tamhane (α = 0,05). O cimento Fuji IX (24 horas) apresentou aumento significativo na resistência máxima à tração e o Ketac Molar (24 horas) na resistência de união à dentina, após a aplicação do US. Os grupos controle destes materiais também apresentaram aumento da resistência após 30 dias de armazenamento. Em todos os outros grupos experimentais não houve alteração significativa após a aplicação de US ou após diferentes períodos de armazenamento. A aplicação do ultra-som aumentou a resistência máxima à tração e de união à dentina, após 24 horas de armazenamento, quando se utilizou respectivamente, os cimentos Fuji IX e Ketac Molar. / Abstract: This study investigated the GICs ultimate tensile strength and bond to dentine after ultrasonic excitation and after periods of the 24 hours and 30 days storage in distilled water at 37ºC, using microtensile test. Two high viscosity GICs, Fuji IX GP and Molar Ketac, and the resin modified GIC Vitremer were used. Twelve specimens for each material were prepared, 6 formed the control group and 6 received treatment with US, por 30 seconds. For the ultimate tensile strength experiment, a cross-sectional area of 0.91mm2 (± 0.1) in the specimens were obtained. For the tensile bond strength to dentine test, 36 third molar were selected and randomly divided into groups, with a cross-sectional area of 0.93 mm2 (± 0.09). All specimens were tested in a microtensile test machine. The data were evaluated by analysis of variance and corrected by Welch (p<0.001) and Tamhane tests (α = 0.05). Fuji IX (24 hours) had significant increase in the ultimate tensile strength and Ketac Molar (24 hours) had significant increase in the tensile strength of union to dentine, after the application of the US. The control groups of the Fuji IX and Ketac Molar had increase in the tensile strength after 30 days of storage. All the other groups, did not show significant difference neither when US application was used nor between different storage times. The ultrasound application increased the ultimate tensile strength and bond to the dentine, after 24 hours of storage, when if it used respectively, the Ketac Molar and Fuji IX cements. / Mestre
45

Efeito da clorexidina na resistência de união entre adesivo autocondicionante e dentina / Effect of chlorhexidine on bond strength between self-etching adhesive and dentin

Pomacóndor Hernández, César Alberto, 1982- 18 August 2018 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:53:20Z (GMT). No. of bitstreams: 1 PomacondorHernandez_CesarAlberto_M.pdf: 1946502 bytes, checksum: 842f8e2e23f8ff6c74e3ea3a3c2f7637 (MD5) Previous issue date: 2011 / Resumo: Na tentativa de prolongar a durabilidade da união resina-dentina, a clorexidina aparece como uma alternativa para preservar a integridade do componente colágeno não envolvido pela camada híbrida. O presente estudo teve como objetivo avaliar o efeito da clorexidina na interação entre o adesivo autocondicionante de dois frascos Adper SE Plus (3M ESPE) e a dentina nas variáveis: a) resistência de união (RU) após 1 dia, 3 meses e 6 meses de armazenamento em água, e b) padrão de fratura. Foram obtidos oito terceiros molares humanos recém extraídos e livres de cárie. O esmalte oclusal e a raiz foram removidos para obter um bloco de dentina de 4mm de espessura com uma superfície plana em dentina média. Cada bloco foi cortado longitudinalmente em duas metades resultando em oito hemiblocos para cada um dos Grupos Controle (C) e Experimental (CHX). Para o Grupo Controle, o Adper SE Plus foi aplicado seguindo as instruções do fabricante: 1 - aplicação do Líquido A, 2 - aplicação ativa do Líquido B por 20s, 3 - leve jato de ar comprimido durante 10s, 4 - aplicação de uma segunda camada de Líquido B, 5 - leve jato de ar comprimido. O adesivo foi fotoativado durante 10s usando a unidade de luz visível Elipar Freelight 2 (3M ESPE) com intensidade de 900 mW/cm2. Para o Grupo Experimental, foi realizado o mesmo procedimento substituindo o Líquido A por uma solução aquosa de digluconato de clorexidina a 2% em peso. Foram construídos blocos de resina composta Filtek Z250 (3M ESPE) sobre a dentina em seis incrementos de 1mm sendo fotoativados durante 20s cada. Depois de 24 horas de armazenamento em água destilada a 37°C, os hemiblocos restaurados foram seccionados perpendiculares à região adesiva nos sentidos mesiodistal e bucolingual e obtidos de 8 a 10 palitos de 0,9mm2 (±0,2mm2), os quais foram divididos aleatoriamente em três grupos de 2 a 4 palitos cada e avaliados após 1 dia, 3 meses e 6 meses de armazenamento em água destilada a 37°C. Para o teste de microtração cada palito foi submetido à tração sob velocidade de 0,5mm/min em uma máquina de ensaios universais. Os valores de RU foram submetidos à Análise de Variância de dois fatores para medidas repetidas (?=0,05), e os padrões de fratura classificados em Microscópio Eletrônico de Varredura. O Grupo Controle apresentou valores de RU estatisticamente não diferentes entre si após 1 dia, 3 meses e 6 meses de armazenamento (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectivamente). Os valores de RU do Grupo Experimental também resultaram estatisticamente não diferentes entre si nos mesmos tempos de armazenamento (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectivamente). Não houve diferença estatística nos valores de RU entre os Grupos Controle e Experimental. Houve predominância de padrões de fraturas coesiva no adesivo, e mista coesiva no adesivo e na resina composta em ambos os grupos e em todos os tempos de armazenamento. Dentro das condições deste estudo, conclui-se que a RU à dentina do Adper SE Plus não diminuiu com o tempo, e não foi negativamente afetada pela clorexidina a 2% / Abstract: In the search for durability of resin-dentin bond, chlorhexidine appears as an alternative to preserve integrity of collagen component not involved by the hybrid layer. This study aimed to evaluate the effect of chlorhexidine in the interaction between two-bottle self-etching adhesive Adper SE Plus (3M ESPE) and dentin, in terms of bond strength (BS) after 1 day, 3 months and 6 months of water storage, and fracture mode analysis. Eight fresh caries-free human third molars were obtained. The occlusal enamel and roots were removed to obtain a 4mm-thick dentin block with a flat surface in middle dentin. Each dentin block was cut longitudinally into halves resulting in eight hemi-blocks for each of the Control (C) and Experimental (CHX) Groups. For the Control Group, Adper SE Plus was applied following the manufacturer's instructions: 1 - application of Liquid A, 2 - active application of Liquid B for 20s, 3 - gentle compressed air stream for 10s, 4 - application of a second layer of Liquid B, 5 - gentle compressed air stream. The adhesive was light cured for 10s using light unit Elipar Freelight 2 (3M ESPE) with a minimum intensity of 900 mW/cm2. For the Experimental Group, it was performed the same procedure replacing the Liquid A with a solution of 2 wt% chlorhexidine digluconate. Resin composite build-ups were constructed with Filtek Z250 resin composite (3M ESPE) in six increments of 1mm and were light cured for 20s each. After 24 hours storage in distilled water at 37°C, restored hemi-blocks were sectioned perpendicular to the adhesive region in mesiodistal and buccolingual directions and were obtained 8 to 10 beams of 0.9mm2 (±0.2mm2), which were randomly divided into three groups of 2 to 4 beams and evaluated after 1 day, 3 months and 6 months of storage in distilled water at 37°C. For the microtensile test, each beam was tested on tensile until failure at a crosshead speed of 0.5mm/min in a universal testing machine. The BS values were subjected to two-way repeated measures ANOVA (?=0.05), and fracture mode classified in Scanning Electron Microscope. The Control Group had BS values not statistically different from each other after 1 day, 3 months and 6 months of storage (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectively). The BS in the Experimental Group also resulted not statistically different from each other at the same times of storage (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectively). There was no statistical difference in BS values between Control and Experimental Groups. There was a predominance of cohesive failure within adhesive resin, and mixed cohesive failure within adhesive resin and resin composite in both groups at all storage times. Under the conditions of this study, it can be concluded that BS of Adper SE Plus to dentin did not diminish with time, and was not adversely affected by 2% chlorhexidine / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
46

Resistencia e morfologia da união de cimentos resinosos dual, autopolimerizavel e auto-adesivo a dentina / Bond strength and interface morphology of dual-cure, auto-cure and self-adhesive resin cement to dentin

Vaz, Ricardo Rodrigues 06 February 2008 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T04:18:14Z (GMT). No. of bitstreams: 1 Vaz_RicardoRodrigues_D.pdf: 6222625 bytes, checksum: 52f9da7090d419c4292ce5867fb19956 (MD5) Previous issue date: 2008 / Resumo: O objetivo deste estudo foi avaliar in vitro a resistência e a morfologia da interface da união entre cimentos resinosos e dentina humana. A superfície oclusal de 20 terceiros molares foi removida e a dentina média preparada com lixa 600 de SiC. As restaurações de resina composta indireta (Sinfony) foram confeccionadas em formato circular com 2mm de espessura, jateadas com óxido de alumínio e silanizadas. Os dentes foram divididos em cinco grupos de acordo com a técnica de cimentação: Grupo I ¿ Rely X Unicem/com fotoativação, Grupo II ¿ Rely X ARC/Single Bond 2/com fotoativação, Grupo III ¿ C&B Cement/All Bond 2, Grupo IV ¿ Rely X ARC/Single Bond 2/sem fotoativação e o Grupo V ¿ Rely X Unicem/sem fotoativação. Após a cimentação os conjuntos dente/restauração foram armazenados em água destilada a 37oC por 24 horas e seccionados em formato de palitos com área quadrada de 0.8±0.2mm2 para o ensaio de tração nos tempos de 24 horas e 30 dias utilizando uma máquina de ensaios universal. O tipo de fratura foi observado e classificado em MEV (microscopia eletrônica de varredura). Os resultados foram submetidos à Análise de Variância e ao teste de Tukey para a comparação entre grupos e ao teste-t pareado para comparação entre os tempos de armazenamento de 24 horas e 30 dias (p<0,05). Para análise da morfologia da união em MEV foram obtidos discos de dentina com espessura de 2mm que após a cimentação conforme os grupos experimentais foram seccionados no sentido mesio-distal e incluídos em resina epóxi para os procedimentos de polimento e metalização. Os resultados revelaram que os grupos III, IV e V apresentaram aumento nos valores da resistência da união estatisticamente significantes no período de armazenamento de 30 dias. Os resultados da resistência da união em relação aos modos de polimerização nos tempos de armazenamento de 24 horas e 30 dias revelaram maiores valores na técnica de fotoativação. As análises dos padrões de fratura em MEV mostraram a predominância de fraturas coesivas no cimento para os grupos I e V nos tempos de 24 horas e 30 dias; para o grupo II houve predominância de fraturas mistas sendo coesivas no cimento, na camada híbrida e no adesivo no tempo de 24 horas e fraturas coesivas no cimento no tempo de 30 dias; no grupo III predominou as fraturas coesivas na camada híbrida nos tempos de 24 horas e 30 dias e finalmente para o grupo IV houve predominância de fraturas mistas, sendo coesivas no cimento, na camada híbrida e no adesivo para os tempos de 24 horas e 30 dias. As análises morfológicas das áreas da união não revelaram a formação da camada híbrida para o cimento auto-adesivo Rely X Unicem, enquanto que os cimentos dual Rely X ARC/Single Bond 2 e autopolimerizável C&B Cement/All Bond 2 apresentaram camada híbrida com semelhante morfologia / Abstract: The aim of this study was to evaluate bond strength and the interface morphology between human dentin and resin cements. Oclusal surfaces of 20 third molars were removed and middle dentin was finished with #600 grit SiC. Circular, 2mm thick, indirect composite resin restorations (Sinfony) were made and sandblasted with aluminum oxide and then silanized. Teeth were divided in five groups according to luting technique: Group I ¿ Rely X Unicem/ light-cure; Group II ¿ Rely X ARC/ Single Bond 2/ light-cure; Group III ¿ C& B Cement/ All Bond 2; Group IV ¿ Rely X ARC/ Single Bond 2/ self-cure and Group V ¿ Rely X Unicem/ self-cure. After cementation the teeth/restoration samples were stored in distilled water for 24 hours at 37oC and cut into beam specimens with 0.8±1.0mm2 cross-sections and microtensile tested after 24 and 30 days using a universal testing machine. Fracture patterns were observed and classified by SEM. Results were submitted to ANOVA and Tukey¿s Test to compare groups and pared t-test to compare the storage times of 24hours and 30 days (p<0,05). To analyze interface morphology, 2mm thick flat dentin discs were obtained. After cementation according to the experimental groups the dentin discs were cut vertically and embedded in epoxy resin for the procedures of finishing and gold-sputter. Results revealed that groups III, IV and V presented statistically significant bond strength increase after a storage period of 30 days. Light-cure groups revealed greater bond strength values at the storage times of 24hours and 30 days. SEM fracture pattern evaluation revealed a predominance of cohesive fractures in cement for groups I and V at 24 hours and 30 days. Group II revealed a higher frequency of mixed fractures which were cohesive in cement, hybrid layer and adhesive at 24 hours and cohesive in cement at 30 days. Group III presented more cohesive fractures at the hybrid layer at 24 hours and 30 days while group IV showed a predominance of mixed fractures which were cohesive in cement, hybrid layer and adhesive at 24hours and 30 days. While the morphologic analysis of bonded areas for the self-adhesive cement Rely X Unicem did not reveal the formation of a hybrid layer, the dual-cure cement Rely X ARC/Single Bond 2 and the self-cure cement C&B Cement/All Bond 2 presented hybrid layers with similar morphology / Doutorado / Materiais Dentarios
47

Contribuição do glutaraldeído como componente de sistemas adesivos dentinários / Influence of glutaraldehyde priming on bond strengths of an experimental adhesive system applied to wet and dry dentin

Renato Cilli 10 August 2007 (has links)
Neste trabalho foram testadas as seguintes hipóteses nulas: 1) Não há diferença entre os valores de resistência de união entre resina restauradora e dentina quando uma solução aquosa de glutaraldeído é aplicada como primer dentinário antes do emprego do agente adesivo; 2) Não há diferença entre os valores de resistência de união, quando a aplicação do mesmo sistema adesivo se dá em condições de dentina úmida ou seca. Dentes humanos foram selecionados, e tiveram sua porção oclusal desgastada, expondo a parte média da dentina coronária para adesão. Quatro grupos foram formados, variando-se a aplicação ou não do primer de glutaraldeído e a condição de umidade dentinária: úmida ou seca. Após aplicação e fotopolimerização do sistema adesivo experimental, foram confeccionados blocos resina composta de 4mm de altura sobre a superfície oclusal e os dentes foram preparados para o teste de microtração para a avaliação da resistência de união. Os resultados obtidos foram submetidos à análise de variância a um critério e teste de Tukey (\'alfa\'\'=0,05). A aplicação do primer de glutaraldeído aumentou significativamente os resultados de resistência de união. Não houve diferença estatística entre o mesmo sistema experimental se aplicado em dentina seca ou úmida. A hipótese 1 não se confirma e aceita-se a hipótese 2. / This work tested the following null hypothesis: 1) There is no difference between resin-dentin bond strengths when a glutaraldehyde primer solution is applied onto demineralized dentin during adhesive bonding. 2) There is no difference between resin-dentin bond strengths when the same experimental adhesives systems are applied whether in dry or wet demineralized dentin conditions. Human, extracted upper third molars were selected. The oclusal surfaces were ground flat, and midcoronal dentin was exposed for bonding. Four groups of six teeth were formed. Two groups were designated for dry dentin technique and two for the wet one. After application and photopolymerization of the bonding system, a 4 mm-high resin core build-up was fabricated over the adhesive layer. Specimens were then prepared for microtensile bond test for bond strengths evaluation. The obtained data were submitted to ANOVA and Tukey test (\'alpha\'=0.05). Glutaraldehyde primer application significantly improved resin-dentin bond strength. No significant difference was observed when the same experimental adhesive system was applied whether in dry or wet dentin conditions. Such results require to reject the first null hypothesis and accept the second one.
48

Resistência de união à dentina de sistemas adesivos irradiados com laser de diodo: estudo in vitro / Bond strength to dentin with adhesive systems irradiated with diode laser: in vitro study

Rafael Massunari Maenosono 26 March 2013 (has links)
A irradiação LASER sobre os sistemas adesivos aplicados em dentina, antes de sua fotoativação, tem sido proposta para aumentar a resistência de união de restaurações adesivas. O objetivo foi avaliar o efeito da irradiação com LASER de Diodo (&#x3BB; = 970nm) sobre diferentes sistemas adesivos na resistência de união imediata à dentina. Oitenta molares humanos hígidos foram aleatoriamente distribuídos em 8 grupos (n=10) de acordo com o sistema adesivo: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus - convencional não simplificado), SB (Adper&#x2122; SingleBond 2 - convencional simplificado), CSE (Clearfil&#x2122; SE Bond - autocondicionante não simplificado), EO (Adper&#x2122; EasyOne - autocondicionante simplificado); e respectivos grupos irradiados com LASER de Diodo (SiroLaser, Sirona Dental). Para avaliar a resistência de união foi realizado teste de microtração, obtendo-se valores em MPa, posteriormente analisados através de ANOVA a 2 critérios, seguido de Tukey para comparações individuais e múltiplos testes t (p<0,05) para comparações entre CONTROLE e LASER do mesmo sistema adesivo. Os valores de resistência de união ± desvio padrão para os grupos sem e com irradiação com LASER foram respectivamente: MP (40,10±10,95 / 35,82±7,17), SB (33,49±6,77 / 43,69±8,15), CSE (43,71±15,71 / 37,95±7,66) e EO (19,67±5,86 / 29,87±6,98). A irradiação com LASER de Diodo provocou um aumento da resistência de união obtida pelos sistemas adesivos SB e EO, mostrando-se uma técnica promissora na obtenção de uma adesão mais efetiva de sistemas adesivos simplificados ao substrato dentinário. / LASER irradiation on adhesive systems before it`s activation has been proposed to increase bond strength of composite restorations to dentin. The objective was to evaluate the effect of Diode LASER irradiation (&#x3BB; = 970nm) on different adhesive systems on immediate bond strength to dentin. Eighty healthy human molars were randomly distributed in 8 groups (n=10) according to the adhesive system: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus, non simplified etch and rinse), SB (Adper&#x2122; SingleBond 2 simplified etch and rinse), CSE (Clearfil&#x2122;SE Bond non simplified self-etch), EO (Adper&#x2122; EasyOne simplified self-etch); and respective groups irradiated with Diode LASER (SiroLaser, Sirona Dental). Microtensile test was performed obtaining bond strength values in MPa whice were analyzed by two way ANOVA, followed by Tukey for individual comparisons and multiple t test (p<0.05) for evaluation of CONTROL and LASER groups with the same adhesive systems. Bond strength values ± standard deviation for groups without and with LASER irradiation were respectively: MP (40.10±10.95 / 35.82±7.17), SB (33.49±6.77 / 43.69±8.15), CSE (43.71±15.71 / 37.95±7.66) and EO (19.67±5.86 / 29.87±6.98). Irradiation with Diode LASER resulted in an increase of SB and EO bond strength values, being considered a promising technic to obtain an improved adhesion of simplified adhesive systems to dentin substrate.
49

Efeito da variação da densidade de energia da ponta e da frequência na resistência de união à dentina de sistema adesivo convencional irradiado com diferentes laseres de alta potência / Variation of the effect of the energy density of the fiber tip and frequency in bond strength to irradiated conventional dentin bonding system with different high-power LASERs

Guilherme Saintive Cardia 15 September 2015 (has links)
O objetivo deste estudo foi comparar o efeito da irradiação de dois tipos de laser (laser Nd:YAG e de Diodo) sobre um sistema adesivo convencional de três passos, utilizando três diferentes densidades de energia da ponta, na resistência de união imediata e após 1 ano. Foram selecionados 70 dentes humanos e cada um teve sua coroa seccionada, expondo a superfície da dentina necessária para os procedimentos adesivos e restauradores. Após o preparo dos dentes, os mesmos foram aleatoriamente subdivididos em 7 grupos (n=10), sendo 6 grupos-teste e um grupo controle. Na sequência, foi aplicado o sistema adesivo Scotchbond&#x2122; Multi- Purpose Plus e, antes de sua fotoativação, em três grupos, o laser Nd:YAG foi utilizado com 3 diferentes densidades de energia (1 509,55 J/cm2, 2 254,77 J/cm2 e 3 127,38 J/cm2), o mesmo procedimento com as mesmas densidades foi realizado nos três demais grupos com o laser de Diodo. Após a irradiação seguida da fotoativação, os dentes foram restaurados com incrementos de resina composta Filtek&#x2122; Z250. Os dentes restaurados foram então imersos em água deionizada e mantidos em estufa a 37oC por um período de 7 dias. Após o armazenamento, os espécimes foram seccionados de modo que se obtivessem palitos com área transversal de aproximadamente 1mm2. De forma aleatória, estes palitos foram separados em 2 grupos: o primeiro submetido imediatamente a testes de microtração em uma máquina de ensaio universal INSTRON 3342 e segundo submetido ao mesmo processo após 1 ano de armazenamento. Os valores de resistência de união foram submetidos aos testes ANOVA e post hoc de Tukey, para que comparações individuais pudessem ser realizadas. Não houve diferença estatisticamente significante entre os lasers utilizados. Os grupos irradiados com ambos os lasers apresentaram resultados similares ao grupo controle, com exceção ao grupo que utilizou o laser de Diodo com menor densidade de energia da (GD3), no qual o resultado foi inferior ao grupo controle no momento imediato. Quedas significativas nos valores de resistência de união foram observadas, com exceção aos grupos que utilizaram o laser de Diodo (GD3 GD2) e o laser Nd:YAG (GNd3). Os diferentes lasers não apresentaram diferença entre si e não foram capazes de promover aumento na resistência e união imediata comparados ao grupo controle. Todos os grupos obtiveram quedas na resistência de união, mesmo em alguns grupos esta queda não sendo significativa. Alterações de alguns parâmetros ou até mesmo a utilização de outro tipo de LASER poderiam ajudar a definir o protocolo ideal para o uso efetivo deste sistema de tratamento adjunto. / The aim of this work was to compare the effect of the irradiation of two types of laser (Nd:YAG and diode laser) on a conventional three-step adhesive system, using three different energy densities of the fiber tip in bond strength immediately and after 1 year. 70 human teeth were selected, and each one had the crown sectioned, exposing the dentin surface for the adhesive and restorative procedures. After teeth preparation, they were randomly divided into 7 groups (n = 10), being 6 test-groups and one control group. Thus, the bonding system Scotchbond&#x2122; Multi-Purpose Plus was applied, and before light cured, the Nd:YAG laser was used in three groups, with three different energy densities of the fiber tip (1 - 509.55 J/cm2, 2 - 254.77 J/cm2 and 3 - 127.38 J/cm2), the same procedures with the same energy densities of the fiber tip were performed for the diode laser. After irradiation followed by light cured, the teeth were restored with composite resin increments (Filtek&#x2122; Z250). The restored teeth were immersed in deionized water and maintained in oven at 37oC for 7 days. After storage, the specimens were sectioned in order to obtain sticks with crosssectional area of approximately 1mm2. Randomly, these sticks were divided into 2 groups: the first one was submitted immediately to microtensile tests in a universal testing machine INSTRON 3342, and the second group was submitted to the same procedure after one year of storage. The bond strength values were submitted to ANOVA and Tukey post hoc tests for individual comparisons. There was no statistically significant difference between the laser s. Irradiated groups showed similar results to the control group, except for the group that used the diode laser with lower energy density of the fiber tip (GD3), in which the results were lower than the control group in the immediate moment. Significant reduction in the values of bond strength were observed, except for the groups that used the diode laser (GD3 - GD2), and the Nd:YAG laser (GNd3). Different lasers did not differ among themselves and were not able to promote an increase in resistance and immediate union compared to the control group. All groups had declines in bond strength, even in some this fall not significant groups. Changes in some parameters or even the use of another type of laser could help define the optimal protocol for the effective use of this adjunctive treatment system.
50

Efeito da variação dos parâmetros de potência e energia por pulso na resistência de união à dentina de sistema adesivo irradiado com laser de diodo / Effect of the variation of the parameters of output power and pulse energy on bond strength to dentin irradiated of conventional adhesive system with diode laser

Adriana Regina Cruz 08 November 2016 (has links)
O uso do laser previamente à polimerização de sistemas adesivos aplicados sobre a dentina tem sido proposto para melhorar a resistência de união à dentina. O objetivo foi avaliar o efeito da variação da potência (P) e da energia por pulso (Ep) na resistência de união à dentina de um sistema adesivo convencional irradiado com laser previamente à fotoativação. Duzentos terceiros molares foram distribuídos aleatoriamente em 10 grupos (n=20) sendo um grupo sem irradiação (Controle) e nove grupos irradiados com laser de Diodo (970 nm) (SiroLaser - Sirona Dental Systems - Benshein, Alemanha), de acordo com a potência (P) e energia por pulso (Ep) utilizados: 1 - 0,5W/0,05J; 2 - 0,5W/0,08J; 3 - 0,5W/0,1J; 4 - 0,8W/0,05J; 5 - 0,8W/0,08J; 6 - 0,8W/0,1J; 7 - 1W/0,05J; 8 - 1W/0,08J; 9 - 1W/0,1J. Em todos os grupos fez-se o condicionamento com ácido fosfórico, aplicação do sistema adesivo convencional de dois passos AdperTM Single Bond 2 (3M ESPE, St Paul, MN, EUA) e restauração com resina composta Z250 (3M). Para avaliar a resistência de união foi realizado teste de microtração obtendo-se os valores em MPa. Os resultados foram analisados pelo ANOVA a dois critérios, seguido de Dunnett t (p < 0,001) para comparação entre os grupos. Os grupos irradiados foram avaliados pelo ANOVA a um critério, seguido dos testes de comparações múltiplas Bonferroni e Tamhane. Os valores de resistência de união ± desvio padrão de todos os grupos foram, respectivamente: 0 - Controle (34,60±10,76); 1 - (19,62±8,65); 2 - (27,56±9,20); 3 - (30,34±7,92); 4 - (23,31±5,96); 5 - (20,93±7,46); 6 - (24,67±8,59); 7 - (23,61±7,04); 8 - (25,94±6,82) e 9 - (21,48±3,59). O laser de Diodo influencia na resistência de união entre os grupos irradiados e não irradiado. A potência de 0,5W e energia por pulso de 0,1J influenciam positivamente nos valores de resistência de união quando o sistema adesivo é irradiado previamente a sua fotoativação. / The use of the laser prior to polymerisation of adhesive systems applied to the dentin has been proposed to improve the bond strength of dentin. The aim of this study was to investigate the effect of the variation of the output power (P) and pulse energy (Ep) on bond strength to dentin irradiated of conventional adhesive system with laser. Two hundred third molars were randomly distributed in 10 groups (n = 20): a group without laser irradiation (group control) and nine groups irradiated with diode laser (970 nm) (SiroLaser Sirona Dental Systems-Benshein, Germany), according to the output power (P) and pulse energy (Ep): 1 - 0,5W/0,05J; 2 - 0,5W/0,08J; 3 - 0,5W/0,1J; 4 - 0,8W/0,05J; 5 - 0,8W/0,08J; 6 - 0,8W/0,1J; 7 - 1W/0,05J; 8 - 1W/0,08J; 9 - 1W/0,1J. It was used in all groups etching with phosphoric acid, application of conventional adhesive system AdperTM Single Bond 2 (3M ESPE, St. Paul, MN, USA) and restoration with composite resin Z250 (3M). Microtensile test was performed obtaining bond strength values in MPa. Results were analyzed by two-ways ANOVA test, followed by Dunnett t (p < 0.001) for comparison between groups. The groups laser irradiated were assessed by one-way ANOVA test and subsequent t test with Bonferroni and Tamhane corrections. Bond strength values ± standard deviation for the groups were, respectively: 0 group control (34.60 ± 10.76); 1 - (19.62 ± 8.65); 2 - (27.56 ± 9.20); 3 - (30.34 ± 7.92); 4 - (23.31 ± 5.96); 5 - (20.93 ± 7.46); 6 - (24.67 ± 8.59); 7 - (7.04 ± 23.61); 8 - (25.94 ± 6.82) and 9 - (3.59 ± 21.48). The Diode laser influences on bond strength between irradiated and without irradiated groups. The output power 0.5W and energy per pulse 0.1J influence positively in the bond strength values when the adhesive system is irradiated prior to their light curing.

Page generated in 0.0805 seconds