• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1015
  • 29
  • 28
  • 28
  • 28
  • 27
  • 17
  • 11
  • 5
  • 4
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1068
  • 564
  • 280
  • 216
  • 190
  • 129
  • 127
  • 111
  • 103
  • 97
  • 89
  • 87
  • 81
  • 77
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Influencia dos hormonios tireoidianos no reparo osseo ao redor de implantes de titanio : estudo histometrico em ratos / Influence of thyroid hormones on bone heading around titanium implants : a histometric study in rats

Feitosa, Daniela da Silva 27 February 2007 (has links)
Orientador: Sergio de Toledo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T11:35:58Z (GMT). No. of bitstreams: 1 Feitosa_DanieladaSilva_M.pdf: 3070475 bytes, checksum: 8b886a0cc7e91cdb336051a875f764c3 (MD5) Previous issue date: 2007 / Resumo: O objetivo do presente estudo foi avaliar, histometricamente, a influência de vdisfunções tireoidianas, hiper e hipotireoidismo, sobre o reparo ósseo ao redor de implantes de titânio inseridos em tíbias de ratos. Foram utilizados 42 ratos Wistar machos aleatoriamente divididos em 3 grupos experimentais: grupo 1 (n=15) -hipertireoidismo (800 mcg de L-tiroxina sódica e 180 mcg de triiodotironina sódica / 1000 ml de água); grupo 2 (n=14) - controle; grupo 3 (n=13) ¿ hipotireoidismo (1000 mg de propiltiouracil / 1000ml de água). Após 98 dias da administração das soluções, a constatação das alterações dos níveis hormonais foi obtida por meio de análise sérica e os implantes foram colocados em uma tíbia por animal. O reparo foi avaliado sessenta dias após o procedimento cirúrgico. Os ratos foram sacrificados e obtidas secções não-descalcificadas. Os parâmetros histométricos, avaliados separadamente na região cortical (zona A) e medular (zona B), foram: porcentagem de osso numa região de 500mm adjacente ao implante (AO), porcentagem de preenchimento ósseo dentro das roscas (PR) e porcentagem de contato direto osso-implante (CD). Os dados coletados foram analisados estatisticamente utilizando a análise de variância ANOVA monofatorial e o teste Tukey (a=5%). Na zona A, observou-se redução do reparo ósseo com a diminuição dos níveis de T3 e T4. Houve redução significante em AO no grupo 3 (93,74±2,70) em relação ao grupo 2 (95,93±1,90). Para PR, os valores foram 78,72±3,88 no grupo 1, 71,92±5,12 no grupo 2 e 65,60±8,76 no grupo 3, estatisticamente diferentes entre si. Para CD, diferença significante foi observada entre os grupos 1 e 3, apresentando respectivamente, 20,76±9,3 e 12,28±9,04. No osso medular, não houve diferenças estatisticamente significantes entre os grupos em nenhum dos parâmetros avaliados. Portanto, dentro dos limites deste estudo, as disfunções tireoidianas, hiper e hipoireoidismo, influenciaram o reparo do osso cortical ao redor de implantes de titânio inseridos em tíbias de ratos / Abstract: The aim of this study was to evaluate, by histometric analysis, the influence of thyroid dysfunctions, hyper and hypothyroidism, on bone healing around titanium implants inserted in rats. Forty-two male Wistar rats were randomly assigned to one of three groups: group 1 (n=15) - hyperthyroidism (800 mcg of sodium Lthyroxine and 180 mcg of sodium triiodothyronine / 1000 ml of water); group 2 (n=14) - control; group 3 (n=13) - hypothyroidism (1000 mg propyllthiouracil / 1000ml of water). Ninety eight days after solutions administration, serum analyses confirmed hormone levels differences and single screw-shaped titanium implants were placed in rat tibiae. Bone healing was evaluated sixty days after surgical procedure. The animals were sacrificed and undecalcified sections from tibiaes with implants were obtained. Percentage of bone in a 500mm-wide zone lateral to the implant (BA), percentage of bone filling within the limits of the implant threads (BF) and percentage of bone-to-implant contact (BIC) were obtained and arranged separately for the cortical (Zone A) and cancellous bone (Zone B). The data were statistically analysed using one-way ANOVA and Tukey¿s test (alpha=5%). In Zone A, intergroup analyses revealed a tendency for reduction in bone repair while hormone levels decreased. There was a statistical reduction in BA in group 3 (93.74±2.70) compared to group 2 (95.93±1.90). T3 and T4 significantly affected BF, showing 78.72±3.88, 71.92±5.12 and 65.60±8.76, for groups 1, 2 e 3, respectively. Differences were also found in BIC, between groups 1(20.76±9.3) and 3 (12.28±9.04). In addition, no differences were observed with respect to Zone B, in any parameter. Therefore, within the limits of the present investigation, thyroid dysfunctions may influence cortical bone repair around titanium implants placed in rats / Mestrado / Periodontia / Mestre em Clínica Odontológica
192

Analise fotoelastica das tensões induzidas por infra-estruturas implanto-suportadas obtidas pelas tecnicas de cimentação dos cilindros e soldagem a laser, antes e apos eletroerosão / Photoelastic analysis of stress transmitted from implant-supported frameworks achieved by cilinders lutingand laser welding techniques before and after eletric discharge machining

Barberi, Juliana Tamião 30 May 2007 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T19:07:40Z (GMT). No. of bitstreams: 1 Barberi_JulianaTamiao_M.pdf: 6032748 bytes, checksum: 3f9207c911e4693fec735f279de88fa3 (MD5) Previous issue date: 2007 / Resumo: O presente estudo avaliou o assentamento passivo em infra-estruturas de próteses fixas implanto-suportadas, através de análise fotoelástica da distribuição de tensões em virtude do grau de desadaptação. A partir de uma matriz metálica no formato e dimensões similares a um arco mandibular, contendo cinco análogos de pilares Micro-Unit (Conexão ¿ São Paulo), foram confeccionadas duas estruturas metálicas fundidas em titânio comercialmente puro (Tritan® ¿ Dentaurum ¿ Alemanha), obtidas pelas seguintes técnicas: Estrutura I, cilindros cimentados com ionômero de vidro modificado por resina (RelyX® Luting 2 ¿ 3M ESPE); e Estrutura II, cilindros soldados a laser e subsequente refinamento por eletroerosão (EDM). A partir de um molde de silicone de duplicação foi confeccionado um modelo em resina fotoelástica (Araldite® GY279BR Huntsman ¿ Araltec Produtos Químicos Ltda. ¿ Guarulhos ¿ São Paulo) com cinco implantes incorporados e pilares Micro-Unit. As estruturas foram então submetidas à análise fotoelástica conduzida pelo aperto dos parafusos na seqüência preconizada 3,2,4,1,5. Seqüencialmente, mensurações foram realizadas na interface estrutura/pilar intermediário com auxílio de um microscópio mensurador, com precisão de 0,0005mm (STM Digital ¿ Olympus ¿ Japão) através do teste do parafuso único. A estrutura dos cilindros cimentados apresentou os melhores resultados com menor valor de desadaptação (42,37 mm) e maior distribuição das tensões, quando comparada à estrutura dos cilindros soldados a laser (83,66 mm), a qual após o procedimento de EDM e subseqüente análise fotoelástica demonstrou redução no grau de desadaptação (53,7 mm) e melhor distribuição de tensão. Pode-se concluir que o processo de cimentação dos cilindros à estrutura optimiza a adaptação marginal desta e minimiza os padrões de tensões, sendo eficaz para a obtenção do assentamento passivo / Abstract: The purpose of the study was to evaluate the passive fit of fixed implantsupported prothesis titanium frameworks, through photoelastic stress analysis. Two frameworks welded in commercially pure titanium (Tritan® ¿ Dentaurum ¿ Germany) were fabricated by two methods based on a metal model composed of five analogous Micro-Unit (Conexão ¿ São Paulo): Framework I, abutment-luted with resin-modified glass ionomer luting cement (RelyX® Luting 2 ¿ 3M ESPE); and framework II, cylinders laser-welding technique and was then refined using electric discharge machining. Photoelastic model was obtained (Araldite® GY279BR Huntsman ¿ Araltec Produtos Químicos Ltda. ¿ Garulhos ¿ São Paulo) with five fixtures and abutments Micro-Unit. Strains were produced around the implant bodies when screws retaining the prosthesis were tightened sequence 3,2,4,1,5, and strains were evaluated by photoelastic analysis. The interfacial gaps between the abutments and fixture were measuremented with an optical microscope (STM Digital ¿ Olympus ¿ Japan) 0,0005mm of precision. The interfacial gaps were smaller in the abutment-luted framework (42,37 mm), demonstrated the lower stress when compared to the laser-welded cylinder framework (83,66 mm). The electric discharge machining (EDM) reduced the gaps at the interfaces (53,7 mm) and the strains for framework welded. It may be concluded that the process of abutment-luted realized in frameworks improves the precise fit of it, can be recommended of achieving precise fit of implant-supported prothesis / Mestrado / Protese Dental / Mestre em Clínica Odontológica
193

Embranquecimento de peças injetadas de polipropileno isotatico contendo 'TIO IND.2'

Maia, Denison Ricardo Justino 12 August 2018 (has links)
Orientador: Marco-Aurelio De Paoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-12T02:38:51Z (GMT). No. of bitstreams: 1 Maia_DenisonRicardoJustino_M.pdf: 5659981 bytes, checksum: 9ffd39a2d7f89050f1be4a3f02262851 (MD5) Previous issue date: 2000 / Mestrado
194

Obtenção de suportes cerâmicos de dióxido de titânio rutilo utilizados em membranas que visam ao tratamento de efluentes radioativos da indústria nuclear

Siciliano, Umberto Cassará de Castellammare Scott, Instituto de Engenharia Nuclear 02 1900 (has links)
Submitted by Almir Azevedo (barbio1313@gmail.com) on 2017-03-27T17:27:33Z No. of bitstreams: 1 dissertação mestrado ien 2017 Umberto Cassará de Castellammare Scott Siciliano.pdf: 11198464 bytes, checksum: 441ee8c1e00226d3b6c9f3bead8a666c (MD5) / Made available in DSpace on 2017-03-27T17:27:33Z (GMT). No. of bitstreams: 1 dissertação mestrado ien 2017 Umberto Cassará de Castellammare Scott Siciliano.pdf: 11198464 bytes, checksum: 441ee8c1e00226d3b6c9f3bead8a666c (MD5) Previous issue date: 2017-02 / Os processos de separação por membranas (PSM) têm sido largamente utilizados para fracionar, concentrar e purificar soluções em: tratamento de resíduos industriais, indústria alimentícia, farmacêutica, dessalinização de água e energia nuclear, em razão dos PSM serem mais econômicos que métodos tradicionais de separação. O aumento da utilização de membranas conduziu à expansão da base de conhecimento de tecnologia de fabricação, resultando em membranas com alta taxa de transferência, melhoria na seletividade e a estabilidade de longo prazo. A nanofiltração é uma técnica recente, sendo um processo capaz de separar partículas na faixa de 5 a 10 Å. A demanda por altas temperaturas de operação e resistência química têm estimulado o desenvolvimento de estruturas inorgânicas, principalmente cerâmicas porosas. Estes materiais podem ser revestidos por polímeros, entretanto, a estabilidade química do componente orgânico irá limitar as aplicações. Os materiais cerâmicos possuem diversas vantagens: estabilidade química, refratariedade e estabilidade física. Apesar destas características favoráveis, estes materiais não têm sido utilizados extensivamente em aplicações de PSM devido à dificuldade em produzir estruturas porosas livre de trincas e com tamanho de poros adequado. Este trabalho visou a produção de suportes de membranas de dióxido de titânio (TiOβ), necessários para compensar a fragilidade das cerâmicas. Para esta finalidade, TiOβ de alta pureza foi utilizado como material inicial, com tamanho médio de partícula igual a 0,1γ μm. A suspensão foi preparada e a secagem foi feita em spray dryer, pois origina material seco com umidade e morfologia controladas. Os suportes foram obtidos por meio de prensagem uniaxial (1,5 kgf.cm-²) seguido de sinterização em temperaturas distintas (1050, 1100 e 1150 ºC). Os suportes foram caracterizados quanto sua porosidade, a partir de métodos como: densidade geométrica, método de Arquimedes e transmissão de raios gama. A permeação foi avaliada em um sistema de célula com deslocamento de fluxo frontal em pressões de até 5 bar. A microscopia eletrônica de varredura permitiu a investigação de modo simples e rápido da morfologia dos suportes. Os resultados mostraram que foi obtida porosidade de aproximadamente 50%, adequada para aplicações como suporte de membrana.
195

Estudo termodinâmico da extração líquido-líquido de ferro (III) e Titânio (IV) pelo ácido bis- (2-etil-hexil) fosfórico (D2EHPA)

Silva, Glauco Corrêa da, Instituto de Engenharia Nuclear January 2004 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-10-11T16:34:25Z No. of bitstreams: 1 GLAUCO CORREA DA SILVA M.pdf: 31495327 bytes, checksum: 7b9163d1cb5b91a2a5b1cbda11272a34 (MD5) / Made available in DSpace on 2017-10-11T16:34:25Z (GMT). No. of bitstreams: 1 GLAUCO CORREA DA SILVA M.pdf: 31495327 bytes, checksum: 7b9163d1cb5b91a2a5b1cbda11272a34 (MD5) Previous issue date: 2004 / A Ilmenita FeTiO3, é um co-produto com baixo valor comercia agregado mineração das popularmente conhecidas areais monazíticas. É obtida durante a separação dos compostos dos elementos das terras raras (Sc, Y, La e Lantanóides), Th, U e Zr Nos processos convencionais de purificação da ilmenita, o dióxido de Titânio TiO2, é obtido em grande quantidade porém com pureza limitada. Estes processos também geram uma quantidade considerável de efluentes e rejeitos. A extração Líquido-Líquido, ELL, pode ser usada como uma alternativa nos processos de separação e purificação para a produção de TiO2 com pureza elevada além de permitir o reciclo de efluentes e minimizar a geração de rejeitos. Este trabalho apresenta o estudo da separação do Fe (III) e Ti (IV) em solução de ácido sulfúrico empregando o processo de ELL. Foram obtidos dados termodinâmicos para a determinação das constantes de distribuição, Kd, em função da acidez livre e das concentrações das espécimes químicas Fe (III) e Ti (IV) em soluções de lixívia sulfúrica de ilmenita. Foram empregadas soluções orgânicas do ácido bis (2-etil-hexil) fosfórico, D2EHPA, como agente extratante. No estudo foram usadas soluções aquosas contendo concentrações de Fe (III) e Ti (IV) variando de 1,0 a 25, 0g.L-1, acidez livre de 5.10-3 a 10mol.L-1 e soluções orgânicas de D2EHPA/querosene de 0,1 a 1,5mol.L-1. A partir dos dados obtidos foi utilizado um código computacional interativo desenvolvido em FORTRAN, denominado código TIFEX, baseado nos modelos termodinâmicos e químicos propostos. O código TIFEX, gerou modelos teóricos preditivos, podendo ser usado para o desenvolvimento de um simulador com o objetivo de estabelecer fluxogramas de processos ELL a serem empregados em unidades de células de misturadores-decantadores em regime contínuo e em contra-corrente, possibilitando modificações para a condução de TiO2 com grau de pureza desejado. Os modelos teóricos apresentaram concordância com os dados experimentais com erros relativos inferiores a 10%. A recuperação dos produtos tanto quanto o tratamento e reciclo dos efluentes e rejeitos gerados no processo também foram investigados. Os resultados obtidos indicaram que o processo de ELL é possível como uma alternativa substituta para os processos convencionais de produção e purificação de TiO2, além de minimizar a emissão de efluentes para o meio ambiente.
196

Análise da passividade e adaptação de infraestruturas de Ti com soldagem a laser vertical e horizontal de borda, cilindro cimentado ou processo CAD/CAM / Analysis of passivity and adaptation of infrastructures Ti laser welding with vertical and horizontal edge, cemented cylinder or process CAD/CAM

Silva, Maíra Daysê Moreira Serra e 06 July 2013 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T01:37:01Z (GMT). No. of bitstreams: 1 Silva_MairaDayseMoreiraSerrae_D.pdf: 4199149 bytes, checksum: b778f7577a1646d77910c20b05ac939f (MD5) Previous issue date: 2013 / Resumo: Este estudo comparou diferentes técnicas para obtenção de infraestruturas protéticas implantossuportadas com menores desajustes verticais e melhor passividade. A partir de uma matriz metálica com paredes planas e dimensões de altura, comprimento e espessura de 25 X 70 X 10 mm, contendo 4 análogos de microunits (3,75 X 13 mm), foram confeccionadas 25 amostras separadas em cinco grupos (n=5): Grupo IM infraestruturas fundidas em monobloco; Grupo ISS infraestruturas fundidas seccionadas e unidas com um ponto de solda a laser; Grupo ICC infraestruturas parafusadas com cilindros cimentados; Grupo ISB infraestruturas submetidas à soldagem de borda com solda a laser; Grupo TCC infraestruturas confeccionadas pelo processo CAD/CAM (Computer Aided Design/Computer Aided Manufacturing). Foram realizadas leituras de desadaptação marginal vertical das infraestruturas, sobre a matriz metálica, em microscópio óptico com precisão de 1,0 ?m e aumento de 120 X. As desadaptações foram quantificadas seguindo o protocolo do teste do parafuso único após torque no parafuso protético de uma das extremidades ( 10 Ncm) e verificado a adaptação nos outros três pilares. Com o intuito de avaliar a passividade das infraestruturas foram analisadas, pela técnica da fotoelasticidade, as tensões geradas nos implantes após aperto de todos os parafusos com auxílio de polariscópio circular equipado com software, capaz de realizar análises qualitativa e quantitativa das tensões. Os valores de desajuste e tensão foram tabulados e submetidos à análise estatística (SAS versão 9.1 - The SAS Institute, Cary, NC, EUA). Para as comparações entre técnica e desajuste vertical foi feito o teste ANOVA com um fator e teste de Tukey (? = 0,05%), e para as comparações das tensões cisalhantes foi realizado ANOVA dois fatores e teste de Tukey (? = 0,05%). Os resultados mostraram que o grupo IM apresentou maior desadaptação marginal; os grupos ISS e ICC apresentaram significativa adaptação marginal e menor concentração de tensão quando comparado ao grupo IM, com a vantagem do grupo ICC eliminar o seccionamento e soldagem; o grupo ISB apresentou melhor adaptação marginal quando comparadas as infraestruturas fundidas, porém com significativa concentração de franjas e tensão nos implantes, e a tecnologia CAD/CAM produziu infraestruturas com melhor adaptação marginal e tensão distribuída de forma equilibrada. Pode-se concluir que técnicas que eliminam ou reduzem pontos de solda como, ISS, ICC e TCC melhoram a passividade e diminuem desadaptação marginal vertical de infraestruturas extensas implantossuportadas / Abstract: This study compared different techniques for obtaining prosthetic implantinfrastructures with lower vertical misfits and passivity. Starting from an metallic with plane walls and dimensions of height, length and thickness of 25 X 70 X 10 mm containing four microunits analogues (3.75 X 13 mm), were prepared twentyfive samples were prepared and divided into five groups (n = 5): Group IM onepiece casted frameworks, Group ISS one-piece casted frameworks sectioned and welded with laser welding; Group ICC with cylinders cemented; Group ISB with cylinders laser-welded, Group TCC frameworks fabricated by the CAD/CAM process (Computer Aided Design / Computer Aided Manufacturing). Measurements were accomplished of the frameworks vertical misfit on metal matrix, in an optical microscope with accuracy of 1.0?m and increased 120 X. The Misfits were quantified according to the protocol of the single screw test after 10Ncm torque on the prosthetic screw and verified the adjustment on the other pillars. Aiming to evaluate the passive infrastructure were analyzed by the technique of photoelasticity the tensions generated in the implants after torque of all screws with the aid of a circular polariscope equipped with software able of performing qualitative and quantitative analyzes of tensions. The misfit values and tension were subjected to statistical analysis (SAS version 9.1 - The SAS Institute, Cary, NC, USA). For comparisons between technical and vertical misfit was done with one way - ANOVA and Tukey's test. (? = 0,05%), and for comparisons of fringe orders and shear stress was performed two factors ANOVA and Tukey test (? = 0,05%). The results showed that the IM group showed higher marginal discrepancy; group ISS and ICC showed significant marginal adaptation and lower stress concentration when compared to IM, with the advantage the ICC group of eliminate sectioning and welding; ISB group showed better marginal adaptation in casted frameworks, but with significant concentration fringe and tension in implants and CAD/CAM technology produced frameworks with best average marginal fit and tension. It can be concluded that techniques that reduce or eliminate welding points as ISS, ICC and TCC improves the passivity and reduce vertical misfit of extensive infrastructure supported by implants / Doutorado / Protese Dental / Doutora em Clínica Odontológica
197

Desajuste marginal de infra-estrutura de protese fixa obtida pela tecnica de fundição sobre-modelo refratario

Correa, Giovani de Oliveira 06 May 2003 (has links)
Orientador : Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T09:18:22Z (GMT). No. of bitstreams: 1 Correa_GiovanideOliveira_M.pdf: 5176132 bytes, checksum: 3f9770e059e64df02a8d6ab5b4053d5b (MD5) Previous issue date: 2003 / Resumo: A soldagem é uma alternativa para a obtenção de melhor ajuste marginal de retentores metálicos de próteses fixas, de três ou mais elementos. No entanto, há a possibilidade de ocorrerem defeitos nas uniões soldadas ou distorções de todo o conjunto. Embora a adaptação não esteja assegurada, as fundições tipo monobloco são vantajosas quanto à economia de tempo, resistência e durabilidade da infra-estrutura. O propósito desse trabalho foi avaliar o desajuste marginal de infra-estruturas de próteses fixas fundidas em monoblocos, porém obtidas por fundição sobre-modelo refratário, comparando os resultados com os obtidos pela técnica convencional de fundição de próteses fixas. A viabilidade da técnica foi simultaneamente medida em estruturas fundidas em Ti c.p. e nas ligas Ti-6AI-4V e Ni-Cr. Inicialmente uma matriz metálica foi duplicada em silicona por adição para a obtenção dos modelos de trabalho. Sobre os modelos foram encerados os padrões simulando infraestruturas de próteses fixas, correspondendo às fundições convencionais nas três ligas avaliadas. Para a fundição sobre-modelo, a matriz metálica foi duplicada e modelos em revestimento foram obtidos (em Rematitan Plus para as estruturas em Ti c.p. e Ti-6AI-4V e em Talladium, para a liga de Ni-Cr). Sobre os modelos de revestimento foram encerados os padrões simulando as infraestruturas protéticas, sendo o conjunto padrões/modelo refratário, incluído para a realização das fundições. As infra-estruturas após a fundição foram jateadas com óxido de alumínio, ajustadas internamente e acabadas com fresas. Os desajustes marginais foram medidos em microscópio mensurador (STM Olympus - Japão) com aumento de 50 X e precisão de 0,5Ilm. Os valores obtidos foram submetidos a análise de variância e ao teste de Tukey em nível de 5% de significância. Os desajustes médios obtidos para a técnica de fundição sobre-modelo (82,86Ilm para Ti c.p.; 64,41 11m Ti-6AI-4V; e, 77,241lm para Ni-Cr) foram significativamente menores que os obtidos pela técnica convencional (106,36Ilm para Ti c.p.; 75,73!lm Ti-6AI-4V; e, 101,96!lm para Ni-Cr). Para ambas as técnicas, dentre os materiais avaliados, o desajuste marginal foi significativamente diferente, apresentando-se na seguinte ordem decrescente: Ti c.p, Ni-Cr e Ti-6AI-4V / Abstract: Soldering has been an alternative for achieving acceptable marginal fit of metallic crowns of 3-unit fixed frameworks to the respective abutments, in detriment of the single-piece casting. However, defects at the joined areas or distortions of the entire frame are frequent. Although adaptation can not be assured, single-piece casting presents advantages such as time saving, strength and strength of the framework. The purpose of this study was to evaluate the marginal fit of frameworks for fixed prostheses using the method of single-piece casting using a refractory die, comparing the results with the conventional casting technique for fixed prosthodontics. The viability of the technique was simultaneously measured in casting frames fabricated from c.p. Ti and Ti-6AI-4V and Ni-Cr alloys. Initially a metallic cast was prepared and duplicated using addition silicone for making working casts. For the conventional technique, the 3unit simulated frameworks were waxed over the working casts. For the single-piece casting, the metallic cast was duplicated and investment dies were made (Rematitan Plus - c.p. Ti and Ti-6AI-4V; Talladium - Ni-Cr). The frameworks were waxed on the investment casts that were invested for the castings. After casting, the frameworks were air-abraded with aluminum oxide particles, adjusted and finished with the aid of wheels. The marginal fit was measured under a measurer microscope (Olympus - Japan) with X50 magnification and the values were submitted to the Tukey's test at a 5% levei of significance. The mean values for the single-piece casting technique (82,86 jJm - c.p.Ti.; 64,41jJm - Ti-6A1-4V; 77,24jJm - Ni-Cr) were significantly lower than the values for the conventional technique (106,36jJm - c.p.Ti.; 75,73jJm - Ti-6AI-4V; 101,96jJm - Ni-Cr). For both techniques, the marginal fit values for the metais evaluated were significantly different, as follow (from the higher to the lower): c.p. Ti, Ni-Cr e Ti-6AI-4V / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
198

Analise quimica e topografica da superficie de implantes de titanio comercialmente puro atraves de espectroscopia de fotoeletrons excitada por raios-X (XPS) e microscopia eletronica de varredura (MEV)

Sardinha, Sandra de Cassia Santana 08 January 2003 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:59:55Z (GMT). No. of bitstreams: 1 Sardinha_SandradeCassiaSantana_D.pdf: 6778496 bytes, checksum: 6e85b28fae3ec96602b176bd2bbce76d (MD5) Previous issue date: 2003 / Resumo: Este trabalho teve como objetivo analisar, química e topograficamente, a superfície de implantes de titânio comercialmente puro, utilizados atualmente na Odontologia. Foram selecionados oito implantes das seguintes marcas comerciais: Conexão - Sistema de Próteses; Lifecore - Biomedical; AS Technology e S - Serson Internacional. As amostras apresentavam tratamento de superfície, através das técnicas de ataque ácido (Conexão) e plasma sprayde titânio (Lifecore-Biomedical; AS Technology e S - Serson International), sendo divididas em quatro grupos, contendo dois implantes do mesmo lote de cada fabricante. As análises foram realizadas através de Espectroscopia de Fotoelétrons Excitada por Raios-X (XPS) e Microscopia Eletrônica de Varredura (MEV). Os resultados da análise química mostraram os elementos titânio (Ti), oxigênio (O), silício (Si), zinco (Zn), alumínio (AI) e carbono (C). O estudo através do MEV revelou a topografia rugosa da superfície e uniformidade entre as roscas dos implantes. Pode-se concluir, deste modo, que houve impurezas na superfície dos implantes, que todas as amostras apresentaram rugosidade de superfície, mas que há necessidade de outros trabalhos que relacionem a presença desses compostos e sua interferência na osseointegração / Abstract: The aim of this study was to analyze the chemical and topography of the surface of currently utilized implants of commercially pure titanium. A total of eight implants were studied (Conexão - Sistema de Próteses, Lifecore Biomedical, AS Technology, and S - Serson International). Ali samples had treatment of surface. The samples were divided into four groups, containing two implants from the same lot of each manufacturer. The analysis of the samples was performed utilizing spectroscopy and electromicroscopy. Results showed predominance of the elements of titanium, oxygen, zinc, aluminum, silicon, and carbon in ali samples studied. The electromicroscopy showed the rough topography of the surface and uniformity between the implants. In conclusion, there were impurities in the surface of the implants. However, further studies are required to investigate the relationship between these chemical components in the surface of implants and their influence in the process of bony integration / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
199

Influencia da soldagem ¿laser¿, eletroerosão e ciclos de cocção da porcelana na adaptação de próteses fixas implanto-retidas fundidas em titanio comercialmente puro e titanio-alumíniovanadio antes e apos a eletroerosão

Ruiz Contreras, Edwin Fernando 30 September 2004 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T00:42:10Z (GMT). No. of bitstreams: 1 RuizContreras_EdwinFernando_D.pdf: 6060406 bytes, checksum: 2ac2aca7f09b3127f18d894c6ca8742b (MD5) Previous issue date: 2004 / Resumo: A confecção de artefatos protéticos implanto-retidos fundidos em titânio, vem destacando-se por aliar propriedades químicas, físicas e mecânicas altamente satisfatórias para este fim. Entretanto, distorções oriundas das diversas etapas da fundição e aplicação do recobrimento estético podem resultar em margens cervicais incompletas. Este estudo propôs-se a avaliar: solda ¿laser¿ e eletroerosão na redução do desajuste marginal de infra-estruturas fundidas em titânio comercialmente puro e titânio-alumínio-vanádio; os efeitos do ciclo de cocção da porcelana no desajuste marginal e; o refinamento marginal com eletroerosão póssimulação dos ciclos. Foram confeccionadas 60 infra-estruturas metálicas, sendo separadas aleatoriamente em 6 grupos (G1 ¿ titânio puro + sem tratamento; G2 ¿ titânio puro + eletroerosão; G3 ¿ titânio puro + solda ¿laser¿; G4- titânio-alumínio-vanádio + sem tratamento; G5 ¿ titânioalumínio- vanádio + eletroerosão; G6 ¿ titânio-alumínio-vanádio + solda ¿laser¿). Após a aplicação dos respectivos tratamentos, as infra-estruturas foram submetidas à simulação dos ciclos de cocção (bonder; opaco; corpo e; glaze) e, posterior, refinamento marginal com eletroerosão. As mensurações foram realizadas após todas as fases do estudo, os dados foram tabulados e submetidos aos testes de Tukey e de Wilcoxon (P<0.05). Os desajustes marginais após o refinamento marginal foram: G1 (81,0µm); G2 (47,6µm); G3 (28,2µm); G4 (59,5µm); G5 (46,6µm); G6 (28,2µm). Concluiu-se que: a solda ¿laser¿ e a eletroerosão foram eficazes na redução dos desajustes nas infra-estruturas em ambas as ligas; a etapa bonder interferiu no desajuste nas infra-estruturas em titânio comercialmente puro e as etapas bonder e corpo interferiram no desajuste nas infra-estruturas em titânio-alumínio-vanádio. O refinamento marginal com eletroerosão (póssimulação) foi eficaz em ambas as ligas / Abstract: Titanium frameworks have been emerging to gather physical, chemical and mechanical characteristics that are very satisfying for implant prosthetic rehabilitation. Although the cast difficult and the large number of firing cycles can result in margins of the prostheses less complete. So, the aim of this study was to evaluate: the laser-welding and spark erosion process in the decrease of unfitted frameworks margins of commercially pure titanium and titanium-aluminum-vanadium alloy; the effects of the ceramic firing cycle over the unfitted frameworks margins and; the marginal refinement by spark erosion after the simulation of firing cycles. Sixty castings frameworks were made from a master die and its divided (G1 ¿pure titanium + without treatment; G2 ¿ pure titanium + spark erosion; G3 ¿ pure titanium + laser welding; G4 ¿ titanium-aluminum-vanadium + without treatment; G5 ¿ titanium-aluminum-vanadium + spark erosion; G6 ¿ titanium-aluminum-vanadium + laser welding). After respective treatments, frameworks were submitted to firing cycle (bonder, opaque, dentin and glaze) and marginal refinement by spark erosion. The marginal fit was measured after the studies¿ steps. Wilcoxon¿s and Tukey¿s tests were used in the statistical analysis of the results (P<0.05). The final mean values of marginal fit were: G1 (81,0µm); G2 (47,6µm); G3 (28,2µm); G4 (59,5µm); G5 (46,6µm); G6 (28,2µm). It was concluded that the spark erosion and the laser-welding were effective in the decrease of marginal unfit of the frameworks on both alloys; the bonder application did interfere on the marginal fit of the commercially pure titanium frameworks and; the bonder and dentin application interfered on the fit of the titanium-aluminumvanadium alloy frameworks. The marginal refinement by spark erosion after firing cycle was effective in cast frameworks on both materials / Doutorado / Protese Dental / Doutor em Clínica Odontológica
200

Utilização da fotocatalise heterogenea na destruição do cianeto : fase gasosa x fase aquosa

Rosa, Cassia Regina 24 November 1998 (has links)
Orientador: Jose Roberto Guimarães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-24T18:03:39Z (GMT). No. of bitstreams: 1 Rosa_CassiaRegina_M.pdf: 2862593 bytes, checksum: 9e17b8744bbe4bf5c8b9c2ae9d662717 (MD5) Previous issue date: 1998 / Resumo: A fotocatálise heterogênea foi o processo utilizado neste trabalho, para desenvolver estudos de degradação do íon cianeto, em fase aquosa e gasosa. O reator fotocatalítico foi preparado fixando-se o fotocatalisador dióxido de titânio na superficie interna de um cilindro de vidro de borossilicato. As fontes de irradiação ultravioleta utilizada, foram as lâmpadas germicida e luz negra, de 30 W de potência. Para o monitoramento da concentração do íon cianeto, foi utilizado um eletrodo sensível ao íon em questão. Na primeira parte do trabalho, a degradação do cianeto foi realizada em fase aquosa, utilizando um sistema em recirculação. Os parâmetros avaliados durante o processo de degradação fotocatalítica foram: o uso de diferentes fontes de irradiação (luz germicida e luz negra), a variação da carga molar, e o uso de diferentes condições de aeração. Os resultados obtidos mostraram ser a luz germicida, mais eficiente na remoção do cianeto, em reação à luz negra, com 81% e 46% de remoção respectivamente. Com a variação da carga molar, uma maior remoção foi obtida para baixos valores de carga molar, sendo que para os valores 3,0, 7,7, 23,2 /lmol min- / Abstract: In this work, the fotocatalysis was used to promote cyanide ion degradation studies, in on aqueous and gaseous phases. Titanium dioxide was fixed on the inner glass cylinder of the photocatalytic reactor inner glass surface of the glass cylinder. The source of irradiation used, were the germicide and black light lamps (30 Watts). The cyanide ion concentration was monitored using an eletrode sensible to the ion in study. The first step of this work, was the stydy of cyanide degradation in the aqueous phase, using a reciculation system. The parameters analyzed that influence the fotocatalytic process were: the use of different sources of irradiation (germicide and black light lamps), molar flow rate variation, and the use of different aeration conditions. The obtained results showed that the germicide lamp, is more efficient that black light while remotion of8l % while 46 % were obtained to the black light lamp. In the molar flow rate variation results, 3,0; 7,7; and 23,2 J.lmolL-I, where the remotion of 83, 80 and 50 %, respectively showing there to be a major disposition of active sites on the photocatalist surface, even to higher values as 239, 284, 372 J.lmolL-I, the obtained remotion was of63, 46 and 48,5 %, respectively, for occurring a active sites saturation on the titanium dioxide surface. The referent result to the medium aeration use, was got ITom a high efficiency whe utilized a photocatalytic reactor aeration, related to the aeration in the solution, and on the lack, being the results 99,2; 78,0 and 74,8 %, respectively. The second estep of this work, was the cyanide degradation in the gas phase, with a single pass though the reactor. The results obtained for concentration of 126, 168,264,63, 127, 101 and 99 ppmv, were 55, 33, 56, 55, 39 and 53 %, of degradation when the germicide lamp was used. When the black light, lamp was used, the remotion obtained were 25, 34 and 38 %, for concentrations of98, 147 and 145 ppmv, respectivelis / Mestrado / Saneamento / Mestre em Engenharia Civil

Page generated in 0.0462 seconds