1

Insamling av dagvatten för toalettspolning i Sverige : Undersökning av befintliga system i Celsiushuset och Sergelhusen med avseende på effektivitet, drift och användarupplevelse / Stormwater harvesting for toilet flushing in Sweden : Investigation of existing systems in Celsiushuset and Sergelhusen regarding efficency, operation and user experience

Larsson, Simon, Lindkvist, Martin January 2023 (has links)
Collecting rainwater for use in toilets is currently uncommon in Sweden. Technology for treatingrainwater and using it for toilet flushing is only found in three buildings in Sweden today. Twoof these buildings are Celsiushuset in Uppsala and Sergelhusen in Stockholm. The buildings thatutilize this technology are relatively newly constructed, and there has been no investigation intohow the systems have performed in terms of operation, efficiency, or user experience. Thesystems in Celsiushuset and Sergelhusen have only been in use for a little over two years andhave not been evaluated during this time. The actual efficiency of the systems is thereforeunknown, and investigations need to be conducted to analyze their efficiency, user experience,and any issues related to system management. This thesis has been conducted in collaboration with Structor Mark Uppsala, which has designedthe external part of the system in the aforementioned buildings. The thesis work has been carriedout using surveys, observations, document analysis, and interviews. The study reveals that thereis some discoloration of the toilet water, which has had an impact on the water and sanitationcomponents. The investigation also shows that most users do not have a problem with moderatediscoloration of the toilet water as long as they are aware of the cause of the discoloration. The amount of rainwater used compared to drinking water in the Celsiushuset system wascalculated to be 12.7 percent since the building's commissioning, but the theoretical efficiency isaround 50 percent. For Sergelhusen, it has not been possible to calculate the actual efficiency, butthe theoretical efficiency is approximately 40 percent. Celsiushuset has had issues with theoperation of the system's control, resulting in the dry-run protection of the pump tripping whenwater should be pumped into the building from the reservoir. Sergelhusen has needed to modifythe system due to excessively high levels of discoloration in the water and has installed additionaltreatment steps, which have led to reduced discoloration. The study shows that discoloration in the toilet water does not have a negative impact on the user'sexperience. However, it is important to consider the choice of materials for the roof and water andsanitation components that are affected by the use of rainwater. Furthermore, the design of the roofis crucial regarding the use of green roofs, which has a significant impact on the quality ofrainwater and requires additional treatment steps in the system.
2

Undersökning av regninsamlingssystem för Uppsala spårvagnsdepå: analys och implementering

von Buxhoeveden, Ulrika, Pettersson, Emma, Larsson, Sofia, Malm, Daniel, Alexandersson, Linnea January 2024 (has links)
Syftet med detta projekt var att förse Region Uppsala med ett förslag på ett hållbart regninsamlingssystem som kan användas vid den spårvagnsdepå som ska byggas utanför Uppsala. Detta i enlighet med regionens hållbarhetsmål, som bland annat anger att vattenkvalitet ska anpassas efter användningsområde. Projektet utfördes på beställning av Region Uppsala, i samarbete med STUNS energi.  För att undersöka befintliga regninsamlingssystem i Sverige användes en semi-systematisk litteraturstudie. De system som undersöktes var huset Celsius i Uppsala, Sergelhusen i Stockholm och Citypassagen i Örebro.  Dessa system jämfördes utifrån fyra kriterier och poängsattes baserat på hur väl de uppnådde dessa. Taktypers påverkan på det insamlade regnvattnets kvalitet jämfördes genom en litteraturstudie. Dessutom utvecklades ytterligare ett poängsystem baserat på Livsmedelsverkets kvalitetskrav för dricksvatten där kvalitetsparametrarna rangordnades utifrån hur allvarliga konsekvenser exponering för dessa skulle ge. För att avgöra vilket ändamål som det insamlade vattnet skulle kunna användas till inom spårvagnsdepån modellerades två system, ett för toalettspolning och ett för spårvagnstvätt. Systemet som Citypassagen använder är mest lämpat för implementering vid depån. Systemet är skyfallssäkert då det finns en dagvattentank innan reningen och eftersom dagvattentanken är av tillräckligt stor kapacitet för att hantera intensivt regn utan att omkringliggande ytor påverkas. Detta regninsamlingssystem har även kapacitet att täcka över 70 % av Citypassagens årliga vattenbehov för spolning av toaletter. Resultaten visar att galvaniserad metall var den mest lämpade taktypen om first flush används. First flush är en metod som används vid regninsamling där den första insamlade vattenvolymen avlägsnas före den faktiska regninsamlingen sker. Om first flush inte användes var gröna tak, takspån av trä eller takpannor av lera de mest lämpliga taktyperna på depåtaket. Gröna tak och takspån av trä bidrar till organiskt material i det insamlade regnvattnet som vid klorrening bildar flyktiga och giftiga biprodukter. Gröna tak och takspån av trä bör därför ej kombineras med regninsamling till en spårvagnstvätt där klorrening förekommer.   Modelleringen av vatteninsamling och förbrukning, baserat på nederbördsdata från 1994–2023, visar att recirkulerat vatten och/eller regnvatten kan ersätta ungefär 99 % av det förväntade vattenbehovet inom depån oavsett val av användningsområde.  Vid ett system anpassat för spolning av toaletter utnyttjas 28,4 % av tillgängligt vatten medan systemet för tvätt av spårvagnar utnyttjar 81,8 %. Utifrån resursutnyttjande av vatten anses därmed spårvagnstvätt vara det bättre lämpade användningsområdet. Dessa resultat är baserade på de största undersökta kapaciteterna hos dagvattentanken vilket motsvarar 105 m3 vid spolning av toaletter respektive 210 m3 vid spårvagnstvätt. Studien visar att implementering av ett regninsamlingssystem vid den planerade spårvagnsdepån är möjligt och att detta bidrar till en avsevärd minskning av användningen av kommunalt dricksvatten. Dessutom kan projektet och dess rekommendationer fungera som modell för framtida initiativ och därigenom främja hållbar utveckling.
3

Feasibility study of evaporative cooling and toilet flushing using rainwater in a public building

Reig Moril, Claudia January 2023 (has links)
The project "Feasibility of evaporative cooling and toilet flushing using rainwater in a public building" combines rainwater harvesting with the evaporative cooling technology and toilet flushing and explores the practicality and viability of implementing this innovative system in the city of Gothenburg, Sweden. This study comprehensively investigates various aspects related to water and energy, and the entire system is computationally modelled using the Equation Engineering Solver (EES) software. The primary objective of the project is to assess the feasibility of utilizing harvested rainwater either for employing evaporative cooling for temperature control or for flushing toilets in a commercial building. By leveraging these sustainable practices, the project aims to reduce both water consumption and energy usage, thereby promoting environmental conservation and decreasing the ecological footprint. The study involves an in-depth analysis of several key aspects. Firstly, the local climate and rainfall patterns in Gothenburg are examined to evaluate the availability and adequacy of rainwater as a resource. Secondly, evaporative cooling technology is extensively investigated to determine its efficiency in cooling indoor spaces. The thermal dynamics and cooling potential of the system are analyzed, taking into account factors such as temperature differentials, humidity levels, and air circulation. The Equation Engineering Solver software is employed to simulate and compute the system's performance under varying conditions, allowing for predictions and optimization. For doing that, three cases with different conditions concerning the priorities of cooling and flushing necessities and the water volume in the two existing tanks in the installation have been developed in order to analyse the benefits they would bring in terms of energy and water savings. The comprehensive analysis of the technical and environmental feasibility of the three cases of study provides some advantageous results. Starting by analyzing the water aspect, in the first case, the one that prioritizes the cooling aspect while the water to fill the toilet flushing necessities is provided just if in the second tank there is any water left, a total of 37% and 10% of the requirements would be filled for the AHU and the toilet flushing respectively. Secondly, the case that still prioritizes the cooling demand but water for toilet flushing is provided as long as the storage tank is half full, meets 69% and 8% of the demand of the AHU and the flushing respectively. Laying aside the flushing aspect considering simply cooling in the third case, 75% of the supply within the AHU is met. When it comes to the thermal part, on the one hand, fractions provided by the new evaporative system are 22%, 32% and 49% respectively. This is due to the fact that almost every month in the three cases studied aims for extra cooling since the system does not hold the quantity of water required and therefore, an extra supply from the current cooling device is needed. Nevertheless, the system brings energy savings of 1005.3, 1510.4 and 2022.4 kWh per year. Furthermore, the energy consumption, in the three cases is very similar and low. The conclusions of the project, from a technical point of view, despite considering the fact that the requirements are not entirely met with actual medium contribution fractions either within the water and cooling aspects, with the existing water availability, the tanks and the pumps sizing and the existing AHU, the system is reliable and is capable to perform properly. Therefore, it can be concluded that it is technically feasible. Concerning the environmental feasibility, the key point of the study, depending on the case, the system would bring different savings. On the one hand, the water savings are 40.3, 47.0 and 8.2 m3 yearly for every case respectively, concluding that the second case is the one that would entail the highest water savings to the system. On the other hand, the energy savings hold values of 1005.3, 1510.4 and 2022.4 kWh annually, with the third case bringing the greatest value. Consequently, the three cases can be considered environmentally feasible since all of them achieve the overall objective of the project, the reduction of water and energy usage. However, depending on the savings’ preferences, either the second case with the highest reduction in water or the third case with the highest decrease in energy could be considered the best ones. From a general point of view, the second case could be the most suitable to set since it is the one that saves more water and moreover, it brings an energy reduction between the average values in the first and in the third case. These outcomes provide valuable insights and inform decision-making processes for the successful implementation and adoption of the system, and they guide future implementation strategies and contributions to sustainable urban development. / Projektet " Genomförbarhet för evaporativ kylning och spolning av WC med regnvatten " kombinerar insamling av regnvatten med evaporativ kylningsteknik och toalettspolning och utforskar möjligheten implementera detta innovativa system i Göteborgs stad, Sverige. Denna studie undersöker aspekter som vatten och energi. Systemet är modellerat med hjälp av programvaran Equation Engineering Solver (EES). Det primära syftet med projektet är att bedöma genomförbarheten av att använda uppsamlat regnvatten antingen för att endast evaporativ kyla för temperaturkontroll i en kommersiell byggnad eller för att spola toaletter med. Genom detta syftar projektet till att minska både vattenförbrukning och energianvändning, och därigenom främja miljö och minimera det ekologiska fotavtrycket. Studien gör en djupgående analys av flera nyckelaspekter. För det första undersöks det lokala klimatetoch nederbördsmönstren i Göteborg för att utvärdera tillgängligheten och tillräckligheten av regnvatten som resurs. För det andra undersöks tekniken för evaporativ kylning för att fastställa dess effektivitet vid kylning av inomhusutrymmen. Systemets kylningspotential analyseras med hänsyn till faktorer som temperaturskillnader, fuktighetsnivåer och luftcirkulation. Programvaran Equation Engineering Solver används för att simulera och beräkna systemets prestanda under varierande förhållanden, vilket möjliggör exakta förutsägelser och optimering.För att göra det har tre fall med olika förutsättningar avseende prioritering av kyl- och spolningsbehov samt vattenvolymen i de två befintliga tankarna i anläggningen testats för att analysera deras respektive energi- och vattenbesparingar. Utifrån vattenaspekten kunde det första fallet, den som prioriterar kyla medan vattnet för att fylla toalettens spolningsbehov tillhandahålls om det finns något vatten kvar i den mindre tanken, fylla totalt 37% och 10% av vattenbehovet för evaporativ kyla respektive toalettspolning. För det andra fallet, prioritering av kylbehovet men vatten för toalettspolning tillhandahålls så länge lagringstanken är halvfull, tillhandahåller 69 % och 8 % av behovet av evaporativ kyla respektive spolningen. För det tredje fallet, där allt vatten avses användas till evaporativ uppfylls 75 % av vattenbehovet. När det gäller den energimässiga aspekten tillhandahålls 22 %, 32 % respektive 49 % av det kylbehovs som krävs. Detta beror på att det under de tre studerade månaderna inte finns tillräckligt med vatten och därför krävs extrakyla. Systemet ger ändå en energibesparingar på 1005, 1510 respektive 2022 kWh per år.Projektets slutsatser, ur teknisk synvinkel, är att trots att man beaktar att hela behovet inte helt uppfylls vare sig inom vatten- och kylaspekterna, med den befintliga vattentillgången, tankarna och pumparnas dimensionering och den befintliga AHU:n är systemet pålitligt och kan fungera korrekt. Därför kan man dra slutsatsen att det är tekniskt genomförbart. När det gäller den miljömässiga genomförbarheten, den viktigaste punkten i studien, skulle systemet medföra olika besparingar beroende på fallet. Å ena sidan är vattenbesparingarna 40,3, 47,0 och 8,2 m3 årligen för varje fall, således är det andra fallet är det som skulle medföra störst vattenbesparing för systemet. Å andra sidan är energibesparingen störst för det tredje fallet. Följaktligen kan de tre fallen anses vara miljömässigt genomförbara eftersom de alla uppnår projektets övergripande mål, att minska vatten- och energianvändningen. Men beroende på besparingarnas preferenser kan antingen det andra fallet med den högsta minskningen av vatten eller det tredje fallet med den högsta minskningen av energi anses vara det bästa. Ur en allmän synvinkel kan det andra fallet vara det mest lämpliga att ställa in eftersom det är det som sparar mer vatten och dessutom ger det en energireduktion mellan medelvärdena i det första och i det tredje fallet. Slutligen ger dessa resultat ger värdefulla insikter hur framtida liknande system kan utformas för att bidrag till hållbar stadsutveckling.