• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 282
  • 21
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 310
  • 106
  • 98
  • 83
  • 71
  • 70
  • 70
  • 66
  • 63
  • 61
  • 59
  • 55
  • 39
  • 37
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Modelo elétrico da impedância do transformador baseado em células RLC passivas

Guimarães, Rogério Coelho January 2010 (has links)
No novo contexto do setor elétrico brasileiro, as concessionárias passam a ter uma nova postura quanto à gestão. A energia elétrica, como produto, como negócio, deve levar lucro às empresas concessionárias. Começam a dar mais importância aos custos, entendendo que vários aspectos técnicos devem ser analisados, visando reduzir perdas substanciais. Assim sendo, o transformador de potência assume uma posição destacada, considerando sua posição estratégica no sistema elétrico, fundamental no processo de transporte e entrega de energia elétrica. Por este motivo vem despertando o interesse no desenvolvimento de estudos e pesquisas no sentido de aumentar sua vida útil. O método de Análise da Resposta em Frequência da impedância do transformador permite obter a “assinatura” do mesmo, a fim de verificar futuras degradações. Este método é adotado por várias empresas em todo o mundo, há mais de três décadas. Embora sua ampla aplicação entre muitas técnicas utilizadas na monitoração e análise de falhas em equipamentos, até agora não houve consenso na interpretação dos resultados obtidos por este método. A dificuldade de correlacionar parâmetros com prováveis falhas tem suscitado pesquisas para obtenção de resultados confiáveis e de interpretação fácil. Este trabalho objetiva determinar um modelo elétrico que represente a característica da resposta em frequência para fins de armazenamento de dados e simulações. A partir de dados reais do teste de resposta em frequência da impedância inseridos no modelo proposto, através de um programa computacional, foi verificada a confiabilidade nas respostas obtidas, comparadas com as reais. Os resultados obtidos asseguram que o modelo proposto é viável de ser aplicado. / In the new context of the Brazilian electric industry, the electric power provider companies have adopted a new administration posture. The electric power, as a product and business, should make the companies profitable. They have been paying more attention to the costs, .learning that many technical aspects should be analyzed in order to reduce substantial losses. Therefore, the power transformer takes an outstanding position, considering its strategic position in the electric system and being essential in the process of transport and delivery of the electric power. For this reason, there has been an interest in the development of studies and research in order to increase its useful life. The method of Frequency Response Analysis of impedance of the power transformer permits to obtain reference parameters of this one, in order to verify future degradations. This method has been adopted by many companies throughout the world for over three decades. Despite its wide application among several techniques used in the supervision and analysis of faults of equipments, there has been no consensus in the interpretation of the results obtained by this method so far. The difficulty of correlating the parameters with probable faults have increased research in order to obtain reliable results and of easy interpretation. This study aims to determine an electric model that represents the characteristic of the frequency response in order to store data and simulations. Starting from the real data of the FRA test inserted in the proposed model through a computer program, the reliability of the obtained responses were verified and compared with the real data. The obtained results assure that the proposed model is viable and can be applied.
152

Desenvolvimento de núcleos para transformadores monofásicos de baixa potência pela metalurgia do pó

Ferreira, Carlos Antônio January 2012 (has links)
O objetivo principal do projeto foi desenvolver, através da metalurgia do pó (M/P), núcleos para transformadores monofásicos de baixa potência. O processo compreende o desenvolvimento de ligas metálicas utilizando pós de ferro, níquel e resina fenólica HRJ. Essas ligas foram misturadas, compactadas e sinterizadas ou curadas, conforme o tipo de liga. Após a confecção dos protótipos, foram feitos testes relacionados às características eletromagnéticas. A partir dos resultados obtidos puderam-se fazer comparações entre um transformador convencional, construído com um núcleo de chapas laminadas de Fe-Si com os núcleos maciços confeccionados utilizando-se a metalurgia do pó. Entre os transformadores construídos a partir da metalurgia do pó, também puderam ser observados os comportamentos com núcleos formados a partir de pó de ferro, liga de ferro e níquel, que foram sinterizados e ainda uma liga de ferro com 1% de resina fenólica HRJ que foi curada para obtenção do núcleo magnético. / The main goal this design was to develop, through process of powder Metallurgy, single-phase transformer cores for low Power. The process include the development alloys using powders of iron, nickel and phenolic resin HRJ. These alloys were mixed, compacted and sintered or cured, according to the type of alloy. After the prototype creation, tests were made related to the electromagnetic characteristics. When the results were ready comparisons were made between a conventional transformer, built with a Fe-Si rolled sheet core and bulky cores made using the powder metallurgy. Between transformers built from the powder metallurgy, could also be observed behaviors with cores formed from iron powder, iron and nickel alloy that was sintered and observed too an iron alloy with 1% phenolic resin HRJ was cured to obtain the magnetic core.
153

Impacto da demanda do Complexo Industrial Ford Nordeste sobre a Indústria de Transformação de Plásticos da Bahia: uma abordagem de economia industrial e regional

Spínola, Vera Maria Luz 30 April 2009 (has links)
Submitted by Núcleo de Pós-Graduação Administração (npgadm@ufba.br) on 2017-11-10T17:38:20Z No. of bitstreams: 1 TESE DE VERA SPINOLA.pdf: 792779 bytes, checksum: e6fbc0c57130fade12398e57974c9885 (MD5) / Approved for entry into archive by Maria Angela Dortas (dortas@ufba.br) on 2017-11-16T15:01:44Z (GMT) No. of bitstreams: 1 TESE DE VERA SPINOLA.pdf: 792779 bytes, checksum: e6fbc0c57130fade12398e57974c9885 (MD5) / Made available in DSpace on 2017-11-16T15:01:44Z (GMT). No. of bitstreams: 1 TESE DE VERA SPINOLA.pdf: 792779 bytes, checksum: e6fbc0c57130fade12398e57974c9885 (MD5) / Considerando o crescente uso do plástico no automóvel, o objetivo do corrente trabalho é estudar os efeitos da demanda do Complexo Industrial Ford Nordeste - em operação desde 2001, em Camaçari, Região Metropolitana de Salvador (RMS), Bahia, Brasil - sobre o aglomerado local de empresas manufatureiras de plásticos, bem como os efeitos para trás sobre a cadeia Petroquímica, produtora de resinas termoplásticas, particularmente o Pólo Petroquímico de Camaçari, implantado em 1978. A partir das idéias de Alfred Marshall sobre as externalidades geradas pela concentração de empresas em aglomerados industriais, formulou-se a hipótese de que a montadora criaria demanda aos transformadores locais de plásticos. Para desenvolver o estudo, inicialmente trava-se um diálogo entre conceitos de correntes teóricas identificadas com a Economia Industrial e Regional relevantes ao entendimento do objeto, a exemplo de barreiras à entrada; economias de escala e de escopo; custos de transação; inovação; capital social; além de algumas idéias de autores vinculados à Geográfica Econômica. O estudo de caso está dividido em três etapas: (1) dinâmica da indústria petroquímica e inserção do Pólo de Camaçari; (2) perfil das empresas de transformação de plásticos particularmente daquelas instaladas na RMS; (3) interface da indústria automobilística com a cadeia petroquímica/artefatos plásticos. Como fontes de pesquisa empírica, foram utilizadas publicações técnicas, a base de dados da Relação Anual de Informações Sociais (RAIS) do Ministério do Trabalho e do Emprego (MTE), e principalmente dados primários coletados diretamente de diferentes representantes do setor, por meio de questionários e entrevistas. Não há evidências de que já se tenham criado as esperadas relações endógenas entre o Complexo Industrial Ford Nordeste e as cadeias produtivas locais.
154

Modelagem e controle de retificadores PWM trifásicos conectados a geradores síncronos a ímãs permanentes em sistemas de conversão de energia eólica

Collier, Daniel Augusto Figueirêdo January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-26T06:04:34Z (GMT). No. of bitstreams: 1 299712.pdf: 14376923 bytes, checksum: 42ba0d1dc1ccdc0c2295e1d99e7e0013 (MD5) / No século XXI, mudanças são esperadas nas formas em que a produção de energia ocorre. Com o desenvolvimento de novas tecnologias, o custo da eletricidade a partir da geração eólica caiu mais de 80% durante os últimos anos. A geração de energia através de sistemas de conversão de energia eólica representará uma parcela considerável da energia elétrica gerada. Nesse contexto, turbinas eólicas equipadas com geradores síncronos a ímãs permanentes apresentam vantagens importantes sobre outros tipos de geradores. No entanto, esses geradores precisam ser conectados a uma rede de distribuição através de conversores estáticos de capacidade nominal. Estes conversores permitem que o sistema de conversão de energia eólica seja utilizado em seu ponto ideal de operação a todo instante. Além disto, os conversores estáticos modernos garantem a melhoria da qualidade da energia gerada e que esta seja transmitida à rede com alto rendimento de conversão e de maneira confiável e flexível. Este trabalho propõe uma nova estratégia de controle de corrente de alto desempenho e elevado fator de potência. A estratégia proposta baseia-se na técnica de autocontrole de corrente para retificadores PWM trifásicos, incrementando-a no que diz respeito à compensação de reativos no gerador. Utiliza-se um estágio retificador PWM trifásico robusto e com baixas perdas de condução. Este retificador é analisado e um esquema apropriado de modulação vetorial é proposto. O sistema de conversão de energia eólica é estudado por simulações numéricas e a técnica de controle de corrente proposta é verificada também de forma experimental em um protótipo de laboratório de 6,5 kVA.
155

Degradação prematura da isolação papel-óleo em transformadores e reatores de potência devido a ação de enxofre corrosivo

Lemos, Luiz Eduardo Friedenberg de January 2015 (has links)
A ação de compostos sulfúricos presentes no óleo isolante de transformadores e reatores de potência ajuda na sua estabilidade à oxidação, porém, com o passar do tempo, provoca a corrosão do cobre, o que leva o equipamento à falha. O teor de enxofre, presente no óleo bruto, foi então reduzido, porém aditivos colocados no óleo isolante para combater a oxidação, particularmente o dibenzil dissulfeto (DBDS), ocasionou falhas prematuras em vários transformadores e reatores no mundo todo. A reação do DBDS com o cobre do condutor forma o composto sulfeto de cobre I (Cu2S), o que ocasiona a redução da rigidez dielétrica da isolação sólida, composta basicamente por papel Kraft. Nesse sentido, este trabalho visa avaliar a degradação prematura da isolação papel-óleo em transformadores e reatores de potência devido a ação de enxofre corrosivo gerado pelo DBDS (dibenzil dissulfeto). Amostras de papel, óleo e cobre antes e após envelhecimento foram caracterizadas por ensaios físicos, químicos e térmicos. A cromatografia gasosa do óleo após teste de aumento de temperatura mostrou evolução de CO, CO2, CH4, C2H4 e C2H6 na amostra com DBDS, ao passo que na amostra do óleo normal não houve geração de gases, e na amostra passivada, retornou a valores ainda inferiores àqueles obtidos para o óleo normal. O papel Kraft envelhecido apresentou um decréscimo na sua estabilidade térmica (80ºC) quando comparado com o papel novo, indicando início da degradação deste material em temperatura inferior ao papel novo, sendo que no FTIR uma banda de grupos funcionais aminas e amidas e as bandas dos grupos nitrila, que aparecem no papel novo, não se verificaram na amostra envelhecida. O cobre nu, imerso no óleo mineral isolante (OMI) com DBDS, apresentou contaminação por Cu2S, o que mostrou ser o OMI corrosivo, e a amostra de cobre imersa em OMI com DBDS e passivado, resultou não corrosivo, o que mostra o efeito protetor do passivador. / Power transformers and reactors are equipments of vital importance for any electrical power grid, which intends to provide electrical energy efficiently and reliably in order to face the needful demands for economic development and life quality improvement. Sulfur compounds present in the oils, improves its oxidation stability, however, its reaction with copper, over the time, provoking corrosion, has proved to be harmful to the equipments. A few years ago, sudden failures, especially involving step up transformers and reactors, have been concerning people responsible for the electrical power grids worldwide. Researches pointed out to the inhibitor of oxidation dibenzyldisulfide (DBDS) as the root of the problem. The DBDS reacts with the copper forming copper sulfide, Cu2S, reducing considerably the dielectric strength of the Kraft paper, leading the insulation to fail prematurely. As a result, there are high economic losses and equipments unavailability as well. Regarding the scenario presented, this work intends to assess the power transformers and reactors paper-oil insulation premature degradation due to copper sulfide jeopardy, arose by DBDS. Kraft paper, oil and copper new samples and after being aged, were characterized by physical - humidity, grammage and density (paper and oil), MEV (paper and copper) - chemical – corrosivity and DGA (oil), FTIR (paper) – and thermal tests – TGA (paper). The test of oil corrosivity showed to be neutral for the normal oil sample, and harmful to copper for the oil sample inhibited with DBDS, as well as the protection exerted by the passivated oil sample. The results of DGA after the test with high temperature, showed an evolution of CO, CO2, CH4, C2H4 and C2H6 in the sample inhibited with DBDS, whilst in the normal oil sample there was no gas generation, and in the oil sample passivated the gas concentrations resulted even lower than in the normal oil sample. The aged Kraft paper presented a decrease in its termic stability (80ºC) in comparison with the new Kraft paper, what indicates the degradation beginning of this material occurs at a lower temperature in relation of the new paper. Regarding the Fourier Infrared test (FTIR), one band of amines and amides functional groups, and the nitrile groups, which were shown in the new paper sample, could not be figured out in the aged paper. The copper immersed in oil with DBDS, showed Cu2S contamination, what asserts the oil as corrosive, on the other hand, the copper sample immersed in passivated oil was clean, what has proved the passivator protection.
156

Estudo da influência da conexão e aterramento de transformadores trifásicos em variações de tensão de curta duração

Costa, Lucas Araujo da January 2018 (has links)
Sendo as interrupções, os afundamentos de tensão e as sobretensões distúrbios de Qualidade de Energia Elétrica (QEE) com potencial de grande impacto econômico, estudos que procuram alternativas de mitigação de seus efeitos ou prevenção de sua ocorrência têm sido amplamente realizados nas últimas décadas. Uma das metodologias de avaliação de sua ocorrência é realizada pela predição, que geralmente se concentra em simulações de faltas em parcelas de sistemas elétricos de potência. Nos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST), encontra-se a denominação geral de Variações de Tensão de Curta Duração (VTCD) para estes três tipos de distúrbios, os quais podem ser classificados tanto por sua magnitude quanto por sua duração. Nesse contexto, este trabalho avalia pela predição a influência exercida pela conexão e o aterramento do neutro de transformadores trifásicos nas quantidades de VTCD, especialmente de afundamentos de tensão, e no valor do índice Fator de Impacto (FI) do PRODIST, que são observados em um nó com conexão a um consumidor industrial Realizam-se estudos de caso sobre um sistema de potência simulado no software Alternative Transients Program (ATP), o qual possui dois transformadores em sua rede: um transformador da subestação e outro na entrada do nó do consumidor industrial. Consideram-se duas conexões possíveis para o transformador de entrada, e aplica-se uma resistência de aterramento para o neutro de ambos os transformadores em cada caso, alteram-se o seu valor. Verificam-se as tensões no nó do consumidor industrial de duas formas diferentes: tensões fase-terra e tensões fase-fase. Observa-se, assim, que há diferenças para estas quantidades e para o valor do FI devidas à forma de conexão do transformador de entrada, valor da resistência de aterramento de neutro de ambos os transformadores e formas de verificação das tensões. / Since interruptions, voltage sags and overvoltages are Power Quality (PQ) disturbances with great economic impact potential, studies that seek alternatives to mitigate its effects or to prevent its occurrence have been done widely in the last decades. One of the methodologies to assess its occurrence is performed by prediction, which usually focuses on power systems fault simulations. In the Brazilian norm of PQ, there is the general designation short duration voltage variation (VTCD) for these three types of disturbances, which are classified both in terms of magnitude and duration. In this context, this work assess by the prediction the influence of three-phase transformers winding connection and neutral grounding in the quantities of VTCD, especially voltage sags, and in the index value Impact Factor (FI) of the Brazilian regulation standard, which are observed in a node with connection to an industrial consumer. The case studies are performed on a simulated power system in the Alternative Transients Program (ATP), which has two transformers in its network: one substation transformer and another at entrance of the industrial consumer node. Two possible winding connections are considered for the entrance transformer, and a ground resistance is applied to the neutral of both transformers in each case, being changed their value. Voltages in the industrial consumer node are verified by two different ways: phase-to-ground voltages and phase-to-phase voltages. It is observed that there are differences for these quantities and for the value of the FI due to the winding connection of the entrance transformer, the value of the neutral ground resistance of both transformers and the ways of voltage verification.
157

Modelagem e otimização de transformadores levando em conta sua vida útil

Ries, Lisandra Kittel January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2013. / Made available in DSpace on 2013-06-26T01:14:47Z (GMT). No. of bitstreams: 1 316510.pdf: 3168406 bytes, checksum: b7ead59d3e54f59f41cd1f6647f1eccd (MD5) / O estudo dos transformadores é assunto de diversos trabalhos científicos. Utiliza-se muito o método dos elementos finitos para este fim, pois é uma ferramenta eficaz e precisa para a representação dos fenômenos eletromagnéticos. Porém em uma etapa de pré-dimensionamento este método pode ser considerado demorado em questões de tempo de cálculo. Assim, neste trabalho, utiliza-se um software chamado CADES, que a partir de um modelo analítico tem-se uma solução otima após um determinado número de iterações. O principal atrativo na utilização deste software foi sua facilidade de implementação matemática e exploração de variáveis. O modelo analítico apresenta um grande número de variáveis permitindo ter uma grande variedade de opções para o dimensionamento de transformadores, dependendo dos parâmetros de construção impostos pelos fabricantes. Uma das contribuições desta pesquisa é que parâmetros de custo de fabricação e custo capitalizado são partes da otimização e assim aspectos econômicos serão estudados dentro de um cenário de corte de gastos. O custo capitalizado do transformador é a soma do custo de fabricação com o custo das perdas sobre sua vida útil. Inicialmente o estudo consistirá na proposta de um modelo analítico de um transformador trifásico. Este modelo é validado através do método dos elementos finitos utilizando o software EFCAD e através do método em rede de relutâncias utilizando o software Reluctool, para as variáveis de indutância de magnetização e dispersão. Após a inserção dos modelos por rede de relutâncias no modelo analítico a otimização é implementada no CADES para diversos parâmetros de entrada impostos pelos fabricantes, e diferentes parâmetros de estudo como: permeabilidade relativa do ferro linear e saturada, bobinagem feita com cobre ou alumínio, etc. Alguns resultados são mostrados utilizando a metodologia de Pareto.<br> / Abstract : The study of transformers is the matter of many scientific studies. The finite element analysis is very used for this purpose because it is an efficient and accurate tool for electromagnetic phenomena representation. However in a stage of pre-dimensioning this method can be considered very time-consuming. Therefore, we will use a software called CADES, that from an analytical model, gives an optimal solution after a certain number of iterations. The main advantage of utilizing this software is the mathematical implementation and variables exploration ease. The analytical model shows a large number of variables and it allows a great variety of options for dimensioning transformers, depending on the construction parameters imposed by manufacturers. One of the contributions of this research is that parameters such as manufacturing cost and capitalized cost are parts of the optimization and thus economics aspects will be studied in a cost-cutting scenario. The capitalized cost of the transformer is the sum of the manufacturing cost and cost resulting from the losses on its service life. The study will initially consist of the suggestion of an analytical model of a three- phase transformer. This model is validated by the finite elements method using the software EFCAD and through the reluctance network method using the software Reluctool, for variables like magnetizing and dispersion inductance. After inserting the reluctance network models in the analytical model, the optimization is implemented on CADES for many input parameters imposed by manufacturers and different study parameters such as relative permeability of the iron, linear and non-linear, winding made of copper or aluminum, etc. Some results are shown using Pareto methodology.
158

Estudo de conversores a capacitores chaveados

Martins, Guilherme Brunel January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2013. / Made available in DSpace on 2013-12-05T23:08:51Z (GMT). No. of bitstreams: 1 317920.pdf: 14601002 bytes, checksum: a6c488db2ab895334dcf2ebab5f36e9e (MD5) Previous issue date: 2013 / Uma das principais linhas de pesquisa em eletrônica de potência nas últimas duas décadas foi o desenvolvimento de conversores em alta frequência sem o uso de indutores e transformadores. Peso e volume reduzido, alta densidade de potência e baixa emissão de ruídos eletromagnéticos são resultados do uso apenas de interruptores e capacitores no estágio de potência destes conversores. Nesta dissertação de mestrado realiza-se o estudo teórico e prático de um conversor a capacitor chaveado CC-CC abaixador com 4 estágios, 48 V de tensão de entrada, 12 V de tensão de saída, 100 W de potência de saída apenas utilizando interruptores e capacitores. A partir deste primeiro estudo propõe-se uma nova topologia, um conversor a capacitor CA-CA abaixador com ganho estático ideal igual a ½. Um conversor de 220 V de tensão eficaz de entrada, 110 V de tensão eficaz de saída, 600 W de potência de saída com rendimento máximo de 95,6% é apresentado neste trabalho, constituindo um potencial candidato à substituição dos autotransformadores convencionais (sem controle da tensão de saída) em baixa potência (menos de 1 kW) em aplicações comerciais e residenciais.<br> / Abstract: One of the main line of research in Power Electronics in the last two decades has been the development of high frequency converters without inductors and transformers.Light weight, small size, high power density and low electromagnetic noise are the results of using only switches and capacitors in the power stage of these converters.This masters dissertation presents a theoretical and experimental study of a switched-capacitor step-down converter, 48 V input voltage, 12 V output voltage, 100 W output power using onlys witches and capacitors.From this first study, an AC-AC step-down converter based on the switched-capacitor principle is proposed. A 220 V high-side r.m.s. voltage, 110 V low-side r.m.s. voltage, 600 W output power converter with maximum efficiency is 95,6% is presented on this work, intending to be a potential candidate for replacing the conventional autotransformers (without control of output voltage) inlow power (less than 1 kW) for commercial and residential applications.
159

Ferramenta inteligente para detecção de falhas incipientes em transformadores baseada na análise de gases dissolvidos no óleo isolante

Morais, Diego Roberto January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-22T01:18:17Z (GMT). No. of bitstreams: 1 203190.pdf: 758712 bytes, checksum: 7e55000dc60bef12d568105725407f8b (MD5) / O presente trabalho de mestrado aborda o desenvolvimento e a implementação de uma ferramenta de diagnóstico de falhas em transformadores de potência através da análise dos gases dissolvidos no óleo (DGA). O sistema computacional desenvolvido baseia-se na utilização de forma conjunta de critérios de análise dos gases referenciados em normas, de uma rede neural artificial e de um sistema de inferência fuzzy. O objetivo da ferramenta é fornecer ao usuário uma resposta que combine os melhores resultados não somente dos métodos tradicionais já consolidados na literatura técnica, bem como das técnicas de inteligência artificial, de forma a aumentar a confiabilidade em relação aos métodos individualmente. Para validação da metodologia e da implementação foram utilizados três conjuntos de dados de geração de gases: da IEC, do CEPEL e dados históricos (utilizados para a validação fuzzy), sendo este último grupo obtido junto a um grande concessionário do setor elétrico brasileiro. Os resultados se mostraram promissores no que diz respeito ao diagnóstico de falhas incipientes em transformadores, alcançando níveis de acertos com valores acima de 80%.
160

Automação do ensaio de saturação em transformadores de corrente utilizados em sistemas de transmissão de energia elétrica

Bandeira, Maria Isabel da Costa January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Metrologia Científica e Industrial / Made available in DSpace on 2012-10-22T03:24:14Z (GMT). No. of bitstreams: 1 224206.pdf: 1777568 bytes, checksum: 733507d5310a40c33dd3ba7631922905 (MD5)

Page generated in 0.0951 seconds