• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Utilização da ultra-sonografia para diagnosticar alterações uterinas em cabras, gestação, perdas embrionária-fetal e sexo fetal em ovelhas / Use of the ultrasonography to diagnose uterine alterations in goats, pregnancy, embryonic-fetal losses and fetal sex in ewes

MORAES, Érica Paes Barreto Xavier de 06 March 2006 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2016-10-06T13:30:06Z No. of bitstreams: 1 Erica Paes Barreto Xavier Moraes.pdf: 1264843 bytes, checksum: d90047f80f8b0ca76e8fc19d53fbfa13 (MD5) / Made available in DSpace on 2016-10-06T13:30:07Z (GMT). No. of bitstreams: 1 Erica Paes Barreto Xavier Moraes.pdf: 1264843 bytes, checksum: d90047f80f8b0ca76e8fc19d53fbfa13 (MD5) Previous issue date: 2006-03-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Four experiments have been performed to evaluate the efficiency of ultrasound to detect precocious uterine alterations, pregnancy and sex of the fetus in goat and sheep. The first study determined the incidence of hydrometra and mucometra in Saanen, Alpine American, Boer and Anglo-Nubiana breeds submitted to ultrasound examination to detected early pregnancy using linear (6.0 and 8,0 MHz) and micronconvex (5.0 and 7,5 MHz) transducers. The females that showed uterine liquid or mucus were examined 15 days later to confirm the pathological state and treated with 0.5 mg prostaglandin that did not present estrus. Out of the 143 females examined, 63 (41.9%) were pregnant, 67 (51.6%) were non-pregnant, 11 (6.4%) had hydrometra and 2 (1.6%) had mucometra, corresponding to an incidence of 11%. Moreover, out of the 13 treated females 100% were pregnant. It was concluded that ultrasound is an important tool to detect uterine alterations and that prostaglandin is an efficient treatment for hydrometra and mucometra. The second study tested the viability transrectal linear (6.0 and 8.0 MHz) versus transvaginal micro-convex (5.0 and 7.5 MHz) ultrasound transducers for pregnancy diagnosis in Saint Ines sheep (n = 145). In Group (G) I females (n = 30) were between 15th to 29th days of gestation, in Group II (n = 28) were between 30th to 59th days, in Group III (n = 35) were between 60th to 89th days, in Group IV (n = 32) were between 90th to 139th days and Group V (n = 20) was formed by non-pregnant females. The average time, in seconds, to accomplish the pregnancy diagnosis using either transrectal or transvaginal method was 9.02±5.57 and 11.74±7.06 in GI, 13.90±16.49 and 11.37±12.19 in GII, 56.07±41.21 and 128.33±66.23 in GIII, 5.37±3.40 and 2.69±1.90 in GIV and 14.27±17.60 and 20.35±18.17 in GV, respectively. The transrectal examination was faster (P<0.05) in GI, GIII and GV and slower in GIV and equal (P> 0.05) in GII. It was concluded that pregnancy diagnosis in sheep can be carried out through both methods considering the accessibility, however, the transrectal method was suggested to be faster. In the third study Saint Ines sheep was used to determine the efficiency of ultrasound to evaluate embryonic-fetal development, especially to determine the date of first sign of pregnancy. Sixty pregnant sheep 15th to 45th days of gestation were subjected to ultrasound using a linear transrectal transducer with double frequency (6 and 8 MHz). The identification of earliest and the latest parameters of evaluation were performed between days 15th to 19th (16.7±1.3), day for intra-uterine fluid. The presence of embryonic vesicle was determined between days 16th to 22th (18.6±1.4), day of embryo between 18th to 26th (22.8±1.9), placentoms between days 20th to 29th (25.1±2.0), heartbeat between days 24th to 29th (25.9±1.4), amniotic membrane between days 24th to 32th (27.4±1.8), head and upper body differentiation between days 30th to 37th (33.4±2.2), fetus movement between days 30th to 38th (34.2±2.0), umbilical cord between days 32th to 39th (35.1±1.5), button of the anterior and posterior members between days 34th to 39th (36.7±1.5), ocular globe between days 39th to 43th (40.9±1.2). These results allowed to conclude that the first signs of gestation can be identified as soon as day 15 days of gestation. However, it is wise diagnose pregnancy after day 24 when it is possible to visualize the fetus and the heart beat. In the fourth study the objective was ultrasound during the initial phase of pregnancy to determine embryonic and fetal losses and to identify the sex of the conceptus of Saint Ines sheep. The females (n = 132) were examined in the 30th day to confirm pregnancy and determine embryo viability or loss. The sex or loss of the fetus was determined on days 40th, 50th and 60th using a linear transrectal transducer (6.0 and 8.0 MHz). The sex was identified through the localization of the genital tubercle or the visualization of the external genital. Out of the 160 conceptus examined there was 10.0% (16/160) of losses, being 5.6% (9/160) during embryonic phase and 4.4% (7/160) during the fetal phase, showing no difference (P> 0.05) between both phases. In single gestation there was less conceptus losses 3.9% (73/76) (P< 0.05) which occurred between days 40th and 50th day as well 50th and 60th. One concludes that the ultrasound is an efficient tool to diagnosis early gestation, to monitor embryonic and fetal loss and to identify to the sex Saint Ines of embryos from 50th day of gestation. / Foram conduzidos quatro experimentos para avaliar a eficiência da ultra-sonografia na detecção precoce de alterações uterinas, gestação e constatação do sexo fetal de caprinos e ovinos. No primeiro estudo determinou-se a incidência de hidrometra e mucometra em fêmeas das raças Saanen, Alpina Americana, Boer e Anglo-Nubiana submetidas a exame ultra-sonográfico para diagnosticar precocemente a gestação utilizando-se transdutores linear (6,0 e 8,0 MHz) e micro-convexo (5,0 e 7,5 MHz). As fêmeas com útero contendo líquido ou muco foram novamente examinadas 15 dias depois e, confirmando-se o estado patológico, receberam 0,5 mg de prostaglandina (Dinoprost) que foi repetida 11 dias após naquelas que não mostraram estro. Das 143 fêmeas examinadas, 63 (41,9%) estavam prenhes, 67 (51,6%) não prenhe, 11 (6,4%) com hidrometra e 2 (1,6%) com mucometra, correspondendo a uma incidência de 11% dessas patologias e das 13 fêmeas tratadas 100% apresentaram-se gestantes. Conclui-se que a ultra-sonografia é uma importante ferramenta para detectar alterações uterinas e que a prostaglandina é eficiente no tratamento da hidrometra e mucometra. No segundo testou-se a viabilidade do diagnóstico de gestação em ovelhas Santa Inês (n = 145) pelas vias transretal e transvaginal utilizando, respectivamente, os transdutores linear (6,0 e 8,0 MHz) e micro-convexo (5,0 e 7,5 MHz). No Grupo I, as fêmeas (n = 30) encontravam-se entre o 15º e o 29º dia de gestação, no Grupo II (n = 28) entre o 30º e o 59º dia, no GIII (n = 35) entre o 60º e o 89º dia, no GIV (n = 32) entre o 90º e o 139º e o GV (n = 20) foi formado por fêmeas vazias. O tempo médio, em segundos, para a realização do diagnóstico de gestação, respectivamente, pelas vias transretal e transvaginal foi de 9,02±5,57 e 11,74±7,06 no GI, 13,90±16,49 e 11,37±12,19 no GII, 56,07±41,21 e 128,33±66,23 no GIII, 5,37±3,40 e 2,69±1,90 no GIV e 14,27±17,60 e 20,35±18,17 no GV. O exame transretal foi mais rápido (P < 0,05) no GI, no GIII e no GV, mais lento no GIV e igual (P > 0,05) no GII. Conclui-se que o diagnóstico de gestação em ovelhas pode ser realizado por ambas as vias considerando a acessibilidade, todavia, é sugerida a via transretal quando é considera a rapidez do exame. No terceiro estudo teve-se o objetivo de avaliar ultra-sonograficamente o desenvolvimento embrionário-fetal de ovinos da raça Santa Inês, com o intuito de identificar a data da primeira visualização dos principais parâmetros da gestação. As avaliações ultra-sonográficas foram realizadas com transdutor linear de dupla freqüência (6 e 8 MHz) por via transretal, utilizando-se 60 ovelhas gestantes, entre o 15° e o 45° dia de gestação. A identificação mais precoce e mais tardia dos parâmetros avaliados ocorreu entre o 15º e o 19º (16,7±1,3) dia de gestação para líquido intra-uterino, entre o 16º e o 22º (18,6 ± 1,4) dia para vesícula embrionária, entre o 18° e o 26º (22,8±1,9) dia para embrião, entre o 20º e o 29º (25,1±2,0) dia para placentomas, entre o 24º e o 29º (25,9±1,4) dia para batimento cardíaco, entre o 24º e o 32º (27,4 ± 1,8) dia para membrana amniótica, entre o 30º e o 37º dia (33,4±2,2) para diferenciação entre cabeça e tronco, entre o 30º e o 38º (34,2±2,0) dia para movimento do feto, entre o 32º e o 39º (35,1±1,5) dia para cordão umbilical, entre o 34º e o 39º (36,7±1,5) dia para botão dos membros anteriores e posteriores e entre o 39º e o 43º (40,9±1,2) dia para globo ocular. Os resultados permitem concluir que é possível identificar os primeiros sinais de gestação já no 15º dia, todavia, é prudente que o diagnóstico de gestação somente seja emitido a partir do 24º dia, quando é possível visualizar o embrião e seus batimentos cardíacos No quarto estudo objetivou-se monitorar, ultra-sonograficamente, a fase inicial da gestação para determinar as perdas embrionária e fetal e identificar o sexo dos conceptos de ovelhas Santa Inês. As fêmeas (n = 132) foram examinadas no 30º dia após a cobertura para diagnosticar a gestação, no 35º para confirmar a gestação e observar a viabilidade ou a perda embrionária e no 40º, 50º e 60º dias para avaliar a perda e identificar o sexo dos fetos, utilizando-se um transdutor linear (6,0 e 8,0 MHz) por via transretal. O sexo foi identificado através da localização do tubérculo genital ou da visualização da genitália externa. Dos 160 conceptos monitorados foram registradas 10,0% (16/160) de perdas, sendo 5,6% (9/160) durante a fase embrionária e 4,4% (7/160) na fase fetal, não havendo diferença (P > 0,05) entre ambas as fases. Nas gestações simples, a perda de conceptos, 3,9% (3/76), foi menor (P < 0,05) do que nas múltiplas, 15,5% (13/84). A acurácia da sexagem fetal no 40º dia da gestação foi inferior (P < 0,05) ao do 60º dia, não havendo diferença (P > 0,05) entre o 40º e o 50º dia, bem como entre o 50º e o 60º dia. Conclui-se que a ultra-sonografia é eficaz para diagnosticar precocemente a gestação, monitorar as perdas embrionária e fetal e identificar o sexo de fetos da raça Santa Inês a partir do 50º dia de gestação.
162

Estimativa de propriedades de rigidez da madeira a partir de avaliação acústica na árvore e em toras recém abatidas / Accoustic assessment from the tree and the freshly-felled logs for estimating wood stiffness

Pedroso, Cinthya Bertoldo, 1982- 17 August 2018 (has links)
Orientador: Raquel Gonçalves / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-17T16:58:27Z (GMT). No. of bitstreams: 1 Pedroso_CinthyaBertoldo_M.pdf: 1208192 bytes, checksum: 5bc9a2364d675b24999de25964b5d6d5 (MD5) Previous issue date: 2011 / Resumo: Recentes avanços internacionais indicam a possibilidade de prever, a partir da árvore viva ou em toras recém abatidas, informações estratégicas que podem auxiliar a tomada de decisões econômicas e ambientais e possibilitar utilização mais eficaz da madeira. Estas informações podem ser usadas para classificar as árvores de acordo com as possibilidades de aplicações. Na prática as empresas podem atingir benefícios por meio da aplicação de estratégias baseada na qualidade dos recursos florestais que possuem e nos produtos que desejam comercializar. O objetivo da pesquisa foi verificar a existência de correlações entre propriedades da madeira de espécies florestais plantadas no Brasil (Pinus elliottii, Eucalyptus grandis, Toona ciliata, Clone de Eucalyptus), em termos de rigidez e de resistência, com a velocidade de propagação da onda de ultrassom na árvore e/ou nas toras recém abatidas das quais foram retiradas. Para atingir este objetivo foram realizadas medições de ultrassom em árvores e em toras recém abatidas. As toras foram, então, desdobradas em vigas, as quais foram ensaiadas por ultrassom na condição saturada. As vigas passaram por processo de climatização até atingirem 12% de umidade e novas medições de ultrassom foram realizadas. Após as inferências não destrutivas, as vigas foram ensaiadas à flexão estática com a finalidade de determinar o módulo de lasticidade (EM) e o módulo de ruptura (fm). Os resultados foram avaliados de forma estatística buscando-se correlações entre as respostas de propagação de ondas nas árvores e nas toras recém abatidas com as propriedades de resistência e de rigidez das vigas. Para exemplificar a classificação da madeira a partir do ensaio de ultrassom na árvore ou na tora recém abatida foram utilizadas as faixas de classificação da Norma Australiana AS 2878 (SAA, 1986b). Além disso, verificou-se a existência de correlação entre as velocidades de ultrassom na árvore-tora, árvore-viga e tora-viga, todas na condição saturada. Os resultados obtidos mostraram que é possível obter as propriedades de resistência e de rigidez, assim como, estimar faixa de classificação da madeira a partir da velocidade longitudinal de ultrassom na árvore e/ou da velocidade longitudinal de ultrassom na tora, desde que as mesmas não sejam constituídas essencialmente por madeira juvenil, como foi o caso do clone de eucalipto e do Cedro australiano nessa pesquisa. O modelo de regressão da velocidade árvore-tora foi o que apresentou maior coeficiente de correlação, seguido do modelo de regressão da velocidade tora-viga saturada e, por último, do modelo de regressão da velocidade árvore-viga saturada / Abstract: Recent international advances have pointed out the possibility of estimating, from a live tree or freshly-felled logs, strategic information that may assist in economic and environmental decision making, as well as allowing a more effective application of wood. Such information may be used to classify trees according to their application range. In practice, companies may benefit from that through employing strategies based on the quality of the forest resources they have available and also from the products they intend to market. The aim of this research is to establish whether there is an correlation between the properties of exotic trees growing in Brazil (Pinus elliottii, Eucalyptus grandis, Toona ciliata, Eucalyptus clone) - regarding stiffness and strength - and the velocity of ultrasound wave propagation in the tree and/or freshly-felled logs from which they have been drawn. In order to do so, ultrasound measurements were performed in trees and recently cut logs. Afterwards, logs were unfolded in beams, which in their turn were tested by ultrasound in green condition. Beams underwent an acclimatation process until reaching 12% of moisture content and new ultrasound measurements were performed. Following the nondestructive tests, the beams were tested in static bending in order to establish the modulus of elasticity (EM) and the modulus of rupture (fm). Results were statistically evaluated, seeking correlation between the responses of wave propagation in trees and freshly-felled logs and the beams stiffness and strength properties. As to exemplify wood classification from tree or recently cut log, the Australian Norm AS 2878 (SAA, 1986b) was applied. Further, it was also possible to establish a correlation between ultrasound velocities in tree-log, tree-beam and log-beam, all in green condition. Results obtained showed to be possible to determine stiffness and strength properties as well as to estimate a wood classification layer from ultrasound longitudinal velocity in the tree, and/or ultrasound longitudinal velocity in the freshly-felled logs , unless the wood are essentially made up by juvenile wood, as happened with the eucalyptus clone and the Australian Cedrus in the present research. The model regression tree-log velocity was the one that presented the highest correlation coefficient, followed by the regression saturated log-beam velocity and, lastly, the regression saturated tree-beam velocity / Mestrado / Construções Rurais e Ambiencia / Mestre em Engenharia Agrícola
163

Detecção de ocos em toras utilizando métodos de propagação de ondas ultrassônicas / Detention of hollow in logs using method of propagation of ultrasonic waves

Secco, Chiara Barros 18 August 2018 (has links)
Orientadores: Raquel Gonçalves, Domingos Guilherme Pellegino Cerri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-18T00:29:57Z (GMT). No. of bitstreams: 1 Secco_ChiaraBarros_M.pdf: 3669788 bytes, checksum: 2b38686e92e5a9aff18827f4f5d1eed1 (MD5) Previous issue date: 2011 / Resumo: Um dos grandes problemas enfrentados pelos empresários na exploração legal da floresta são as perdas decorrentes da escolha de árvores, quer seja pela baixa qualidade da madeira ou pelo baixo rendimento. As árvores com troncos classificados como sendo de baixo valor comercial, por uma das duas razões acima indicadas, deveriam ser preservadas, pois são importantes como produtoras de sementes, fonte de alimentos, abrigo para animais e preservação da floresta, podendo fazer parte, portanto, da reserva legal ou do montante que não deve ser explorado. Por outro lado, alguns empresários do ramo de móveis designs se interessam pela utilização de partes do tronco que tenham os ocos. No entanto, para que essa utilização seja realizada é importante que se conheça a extensão do oco em relação ao diâmetro e ao comprimento da tora. Dessa forma, para ambas aplicações há a importância de se detectar a existência e se conhecer a extensão do oco na peça. No caso do ultrassom a propagação de ondas é afetada pela presença de um vazio no interior do tronco, provocando variação na velocidade de propagação da onda e na amplitude do sinal emitido. Estas variações poderão ser detectadas pelo equipamento e estudadas para a elaboração de uma imagem que represente a situação interna da tora. Levando em conta os aspectos apresentados, o objetivo geral dessa pesquisa foi avaliar o uso de equipamento de ultrassom, desenvolvido no país, como ferramenta para a detecção de ocos em secções de toras de árvores de espécie nativa e avaliar metodologia de elaboração de imagem (pós-processada) utilizando essa tecnologia (tomografia ultrassônica). Os resultados mostraram que a técnica (ultrassom) e o equipamento utilizado têm sensibilidade para serem utilizados em inspeções de árvores e que, por meio da variação da velocidade foi possível elaborar imagens que reproduziram, de forma aproximada, a presença do oco e de sua extensão. As conclusões da pesquisa indicam a importância de continuidade do estudo, principalmente com foco no desenvolvimento de algoritmos e software dedicados à aplicação da metodologia / Abstract: One of the great problems faced for the entrepreneurs in the legal exploration of the forest is the decurrent losses of the choice of trees, wants either for low the quality of the wood or for the low income. The trees with classified trunks as being of low commercial value, by one of the two reasons above indicated, would have to be preserved, therefore they are important as producing of seeds, source of foods, shelter for animals and preservation of the forest, being able to be part, therefore, of the legal reserve or the sum that does not have to be explored. On the other hand, some entrepreneurs of the branch of furniture designs if interest for the use of parts of the trunk that have the hollow ones. However, so that this use is carried through is important that if it knows the extension of the hollow one in relation to the diameter and the length of the log. Of this form, for both applications it has the importance of if detecting the existence and if knowing the extension of the hollow one in the part. In the case of ultrassom the propagation of waves is affected by the presence of an emptiness in the interior of the trunk, having provoked variation in the speed of propagation of the wave and in the amplitude of the emitted signal. These variations could be detected by the equipment and be studied for the elaboration of an image that represents the internal situation of the log. Taking in account the presented aspects, the general objective of this research was to evaluate the equipment use of ultrasound, developed in the country, as tool for the detention of hollow in log sections of trees of native species and evaluating methodology of image elaboration (after-processed) using this technology (ultrasonic tomography). The results had shown that the technique (ultrasound) and the used equipment has sensitivity to be used in inspections of trees and that, by means of the variation of the speed were possible to elaborate images that had reproduced, of approached form, the presence of the hollow one and its extension. The conclusions of the research indicate the importance of continuity of the study, mainly with focus in the development of dedicated algorithms and software to the application of the methodology / Mestrado / Construções Rurais e Ambiencia / Mestre em Engenharia Agrícola
164

A reação de Baylis-Hillman em sintese organica : estudos visando o aumento da velocidade de reação, a sintese de Heterociclos e a sua aplicação na preparação alcaloides / Baylis-Hilman reaction in organic synthesis: studies towards enhanced reaction rate, heterocyclic synthesis and application in alkaloids synthesis

Veronese, Demetrius 15 December 2004 (has links)
Orientador: Fernando Antonio Santos Coelho / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-05T16:21:06Z (GMT). No. of bitstreams: 1 Veronese_Demetrius_D.pdf: 8385699 bytes, checksum: 462487559d09c9945f6d57701d8b9ec1 (MD5) Previous issue date: 2004 / Doutorado / Quimica Organica / Doutor em Ciências
165

Estudo da fonoforese de ciclofenaco dietilamonio em voluntarios sadios / Study of diclofenac diethylammonium phonophoresis in healthy human volunteers

Fusaro, Claudio 31 January 2006 (has links)
Orientador: Jose Pedrazzoli Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-06T07:53:42Z (GMT). No. of bitstreams: 1 Fusaro_Claudio_M.pdf: 210087 bytes, checksum: 82412467f7edce8db8bce228762ae320 (MD5) Previous issue date: 2006 / Resumo: O transporte transdérmico de substâncias com o ultra-som terapêutico, método denominado fonoforese, oferece muitas vantagens quando comparado as outras vias de administração de drogas. O objetivo deste estudo foi verificar a influência do ultra-som na absorção de diclofenaco dietilamônio (Cataflam Emulgel®, Novartis) após fonoforese em voluntários sadios. Doze voluntários sadios foram submetidos à aplicação tópica de Cataflam Emulgel® em uma área de 150cm2 na região do dorso. No grupo controle os voluntários receberam a aplicação tópica sem emissão de ultra-som (sham) e o grupo teste recebeu a aplicação tópica através da fonoforese. A concentração plasmática de diclofenaco foi mensurada pelo HPLC (high perfomance liquid chromatography) durante um período de 8h após as aplicações. Neste trabalho demonstramos que a aplicação transdérmica de diclofenaco dietilamônio pela fonoforese, em uma única aplicação, não induz aumento da concentração plasmática quando comparada a aplicação sem ultra-som / Abstract: Transdermal drug delivery with therapeutic ultrasound, method called phonophoresis, offers many advantages when compared to other drug delivery methods. The aim of this study was to verify the influence of ultrasound on the transdermal delivery of diclofenac diethylammonium (Cataflam Emulgel®, Novartis) post phonophoresis in healthy volunteers. Twelve healthy human volunteers were submitted to topical application of Cataflam Emulgel® on 150cm2 area on the dorsum. In the Control Group, the volunteers received topical application with the ultrasound switched off and the Test Group received topical application by phonophoresis. The diclofenac plasma concentration was measured by high perfomance liquid chromatography (HPLC) during a period of 8h after dosing. We provided evidence that transdermal application of diclofenac diethylammonium by phonophoresis, in a single dose, has not induced plasmatic concentration increase when compared to topical application alone / Mestrado / Mestre em Farmacologia
166

Acionamento de elemento ceramicos de tansdutores de ultra-som : circuitos de controle, de transmissão e de recpção / Ultrasound ceramic transducer arrays : control, transmission and reception circuits

Salinet Junior, João Loures 14 August 2018 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-14T01:45:18Z (GMT). No. of bitstreams: 1 SalinetJunior_JoaoLoures_M.pdf: 5974402 bytes, checksum: d82e2a2b0c6f65d111327247ff86a1e4 (MD5) Previous issue date: 2009 / Resumo: Os equipamentos de imagem por ultra-som associam diferentes técnicas e provêm informações não só das estruturas anatômicas como também do estado funcional dos diversos sistemas, em tempo real, com excelente qualidade de imagem. Isto se deve ao desenvolvimento de transdutores cada vez mais aprimorados e, ainda, da utilização de eletrônica digital, analógica e mista com microprocessadores, processadores digitais de sinais (DSPs - digital signal processors) e lógica programável (FPGAs - field programmable gate arrays) cada vez mais rápidos e potentes, aliados à utilização de novas técnicas de processamento digital de sinais e de imagens. O presente trabalho teve como objetivo o desenvolvimento de circuitos de acionamento de elementos cerâmicos de transdutores matriciais. Estes circuitos são responsáveis pela geração e recepção de ondas ultra-sônicas e foram desenvolvidos utilizando técnicas de projetos específicos de placas de circuito impresso de alta freqüência e multicamadas. Foram utilizados componentes SMD (surface-mounted devices) para redução do tamanho do hardware. O sistema é formado por um circuito de controle, uma placa de interligação, uma fonte de alimentação com 10 níveis de tensão, e duas placas de circuito impresso (PCI) contendo os circuitos de transmissão e de recepção (4 canais) para transdutores de ultra-som matriciais. No circuito de controle foi utilizada a linguagem de descrição de hardware VHDL. Este circuito de controle é capaz de executar a variação de largura de pulso, taxa de repetição e defasagem de acionamento dos elementos do transdutor matricial para focalização e deflexão do feixe acústico. Os circuitos de transmissão geram pulsos de até +65V e são disparados pelos pulsos digitais do circuito de controle (mínimo de 20ns de largura). Os circuitos de proteção são eficientes atenuando os pulsos de alta tensão na entrada do circuito de recepção e permitindo a passagem dos ecos. Os circuitos de recepção são formados por circuitos integrados de tecnologia mista (analógico e digital) com faixa de passagem de 100 MHz, baixo ruído e ganho máximo de 70dB. Este ganho pode ser configurado através dos três estágios de amplificação independentes do componente utilizado (LNA, VCA e PGA). O sistema foi testado em laboratório e apresentou desempenho adequado, mostrando-se versátil, permitindo seu uso com transdutores matriciais e mostrando-se interessante ferramenta para laboratórios de ensino e pesquisa em ultra-som. / Abstract: Ultrasound image equipments associate different techniques to provide not only anatomical but also functional information of body parts and organs in real time and with excellent image quality. This is due to great advances in transducer technology and also to digital and analog electronics with the use of microcomputers, digital signal processors (DSPs) and field programmable gate arrays (FPGAs) even faster and powerful, allied to new digital signal and image processing techniques. The objective of the present work was the development and construction of circuits to actuate on piezoelectric ceramic transducer arrays. The circuits are able to generate and receive ultrasound waves and were developed with techniques for high frequency multilayer printed circuit boards. In order to reduce hardware size it was used surface mounted devices (SMD). The system consists of a control circuit, a interconnection board, power supply (10 different voltage), two four channel printed circuit boards with the transmission and reception circuits to be used with transducer arrays. It was used VHDL for hardware description language and the control circuit defines pulse width, repetition rate and temporal phasing for activation of each element of the transducer array enabling focusing and ultrasound beam in different directions. The transmission circuits generate pulses up to +65V that are triggered by the control circuit (20 ns minimum pulse width). The protection circuit is very efficient avoiding high tension electrical surges. The reception circuits have mixed technologies (analog and digital integrated circuits) with 100 MHz bandwidth , low noise and up to 70 dB gain. This gain can be programmed through 3 independent amplification stages (LNA, VCA and PGA). The system has been tested in laboratory and presented adequate performance, being versatile and allowing its use with array transducers becoming an interesting tool for education and research purposes. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
167

Desenvolvimento e avaliação de um sistema de sincronismo entre a colhedora de cana-de-açucar e o tranbordo / Development and valuation of the system of synchronism between surgarcane harvester and infield wagon

Baldo, Rodrigo Fernando Galzerano, 1978- 08 September 2007 (has links)
Orientador: Paulo S. Graziano Magalhães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-10T17:13:32Z (GMT). No. of bitstreams: 1 Baldo_RodrigoFernandoGalzerano_M.pdf: 847065 bytes, checksum: 5e6b7505ee91e4092e5df6b231724a26 (MD5) Previous issue date: 2007 / Resumo: Um dos problemas encontrados na colheita mecanizada da cana-de-açúcar é a falta de sincronismo entre a colhedora e o transbordo, ocasionando perdas tanto de material como de capacidade operacional. A presente pesquisa teve como objetivo desenvolver um sistema capaz de auxiliar no sincronismo entre a colhedora e o veículo de transbordo através de comunicação sem fio utilizando radio freqüência. Dois sensores de ultra-som acoplados ao elevador da colhedora de cana-de-açúcar e um microprocessador, gerenciam tais informações gerando correta sincronia entre as máquinas. O sistema foi testado em laboratório e em campo cumprindo corretamente a função de manter as máquinas em sincronia, indicando e alertando aos operadores as suas posições relativas. O sistema desenvolvido reduziu as perdas de rebolo em cerca de 60 kg ha-1 comparado com a colheita realizada com o sistema desligado, além de melhorar o rendimento operacional da colhedora / Abstract: One of the problems found in mechanical harvesting of sugar cane is the lack of synchronism between the harvester and the infield wagon, causing crop losses as well as reducing the operational capacity. The objective of the present research was to design a system capable to synchronize the sugar cane harvester with the wagon. The communication between tractor and harvester is wireless. The designed system allows the machinery to keep their alignment. The communication among them such us relative position, beginning and end of the harvest line is by radio frequency. Two ultrasound sensors, coupled to the elevator and a microprocessor manage such information generating a correct synchronization among the machines. The system was tested at laboratory and field performing its function adequately, maintaining the two machines in synchronization, indicating and alerting to the operators their relative positions. The developed system reduced the sugar cane lost in 60 kg ha-1 comparing with a harvest with the system turned off and improved the operational capacity of the harvester / Mestrado / Maquinas Agricolas / Mestre em Engenharia Agrícola
168

Simuladores para medição de fluxo de liquidos por efeito doppler para controle de qualidade de equipamentos de ultra-sonografia / Doppler phantoms for flow measurement of liquids for ultrasond equipment quality control

Coiado, Olívia Campos 29 July 2008 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T20:21:02Z (GMT). No. of bitstreams: 1 Coiado_OliviaCampos_M.pdf: 1928451 bytes, checksum: 200e54f85b01a846302bf1f12e118a94 (MD5) Previous issue date: 2008 / Resumo: Neste trabalho é proposto o desenvolvimento de phantoms que permitam o Controle de Qualidade do modo Doppler de funcionamento de equipamentos de ultra-sonografia com tecnologia nacional e preço acessível. O dispositivo é basicamente um circuito hidráulico contendo uma bomba peristáltica, mistura simulando tecido humano, tubos simulando vasos e fluido mimetizador de sangue. Uma bomba peristáltica digital possibilitou a simulação de batimentos cardíacos, com fluxo pulsátil operando com fluxos de 45 até 150 ml/min e pulso que variam de 60 a 200 batimentos por minuto. O fluido mimetizador de sangue simulou as hemácias através de partículas de pó de PVC com diâmetro de aproximadamente 64µm, água destilada, glicerina, detergente e adoçante. Dois tubos simularam artérias com 3 mm de diâmetro interno e 1,5 mm de parede e outro de 4 mm de diâmetro e 1,5 mm de parede. Para a montagem do dispositivo do tecido mimetizador utilizou-se uma mistura contendo pó de grafite, microesferas de vidro de diâmetro entre 45-90 µm e parafina de densidade de 0,834 g/ml para a qual se obteve a velocidade de propagação da onda de 1450 m/s. Para outro tipo de tecido utilizou-se uma mistura contendo ágar, água destilada, glicerina e pó de grafite para a qual a velocidade da onda foi de 1560 m/s. Os testes foram obtidos com imagem ultra-sônica realizada com equipamento no Modo Doppler com transdutor linear operando em 8 MHz, mostrando sua utilidade para testes de controle de qualidade de equipamentos de imagem médica por ultra-som. / Abstract: In this work it is proposed the development of phantoms to allow de quality control of ultrasounds equipments functioning on the Doppler mode with national technology and accessible cost. The device consists of a hydraulic circuit with a peristaltic pump, mixture simulating human tissue, tubes simulating arteries and blood-mimicking fluid. The peristaltic digital pump made it possible the simulation of cardiac beats, operating with flow rates of 45 to 150 ml/min and pulse rates of 60 to 200 beats/min. The blood-mimicking fluid simulated the human red cells as particles of PVC powder with approximately 64 µm diameter, distilled water, glycerin, detergent and dextran. The tubes simulated arteries, one with 3 mm of internal diameter and 1.5 mm of wall thickness and another with 4 mm of diameter and 1.5 mm thickness wall. For the device assembly of the mimicking tissue a mixture was used containing graphite powder, 45-90 µm diameter glass micro spheres and paraffin with 0.834 g/ml of density for which it was obtained 1450 m/s for the speed wave propagation. Another mixture for mimicking tissue it was used agar, distilled water, glycerin and graphite powder for which it was obtained 1560 m/s for the speed wave propagation. The tests were carried out with an ultrasonic image equipment using a linear transducer operating at 8 MHz and have shown that it can be used for quality control tests of ultrasound imaging equipment. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
169

Desenvolvimento embrionário em ratas Wistar prenhes submetidas ao ultra-som terapêutico de 3 MHz

Oliveira, Rosana de Paiva 19 September 2007 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-26T12:56:35Z No. of bitstreams: 1 rosanadepaivaoliveira.pdf: 518922 bytes, checksum: ada6fbbe3e06a4a6b09ddb9b371b9336 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-12-15T12:41:46Z (GMT) No. of bitstreams: 1 rosanadepaivaoliveira.pdf: 518922 bytes, checksum: ada6fbbe3e06a4a6b09ddb9b371b9336 (MD5) / Made available in DSpace on 2016-12-15T12:41:46Z (GMT). No. of bitstreams: 1 rosanadepaivaoliveira.pdf: 518922 bytes, checksum: ada6fbbe3e06a4a6b09ddb9b371b9336 (MD5) Previous issue date: 2007-09-19 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / O ultra-som terapêutico tem amplo uso em diversas disfunções estéticas, cujo tratamento é procurado por mulheres jovens que podem se expor à irradiação em período precoce de gestação. Estudos sobre o efeito do ultra-som terapêutico na gestação são antigos, apresentam resultados controversos, foram realizados com metodologia nem sempre compatível com a clínica, com métodos e técnicas diversas, nenhuma reproduzida em dois trabalhos semelhantes e poucos envolveram as fases precoces de gestação. Os efeitos do ultra-som devem-se ao aumento da permeabilidade por vasodilatação, alteração de difusão de íons, modificação da posição de partículas intra e extracelular e alterações da configuração normal da célula, as quais podem acarretar alteração na sua atividade. Durante a fase precoce do desenvolvimento embrionário as células dependem de síntese protéica e de diversas sinalizações processadas através de canais de sódio e potássio. Além disso, microtúbulos e microfilamentos são extremamente importantes na morfogênese. Portanto, a exposição ao ultra-som poderia acarretar lesões no concepto. No presente estudo, avalia-se o efeito da exposição de ratas, no início da prenhez, ao ultra-som terapêutico por ondas pulsadas e ondas contínuas. A metodologia consistiu em utilizar ratas em dois períodos: pré-implantação (grupos A1, A2 e A3) e implantação (grupos B1, B2 e B3). Os animais foram sedados e expostos ao ultra-som terapêutico de freqüência 3 MHz e intensidade de 0,6 W/cm2 (SATA), por 5min. Os grupos A1 e B1 receberam ondas pulsadas; os grupos A2 e B2, ondas contínuas e os grupos A3 e B3 ultra-som simulado. As ratas foram eutanasiadas no 20o dia pós-inseminação. No sangue coletado procedeu-se à análise do hematócrito, da hemoglobina, dos leucócitos totais, do aspartato aminotransferase (AST/TGO), da alanina aminotransferase (ALT/TGP), do colesterol, dos triglicérides e da creatinina. Posteriormente, os animais foram submetidos à autópsia para identificação de lesões de órgãos internos, remoção e pesagem de fígado, rins e ovários. Foram contados os fetos vivos, malformados, mortos e reabsorvidos; seus cérebros, pulmões, fígados, rins e placentas foram pesados. Os dados obtidos foram analisados por ANOVA - uma via - seguida de teste de Dunnett. Dados não paramétricos foram submetidos aos testes do Qui quadrado ou Kruskall Walis. A hipótese nula foi rejeitada quando p< 0,05. Nas mães não foram observadas alterações de peso corporal e de órgãos, nem da capacidade reprodutiva. Nos fetos o peso relativo do coração, fígado, pulmão e dos rins aumentou no grupo A2; no grupo B2 o coração e o cérebro tiveram seu peso aumentado, e o peso da placenta diminuiu no grupo B1. Em conclusão, no modelo experimental usado, não foram observados efeitos tóxicos do ultra-som sobre o organismo materno, exceto pelo aumento dos triglicerídeos. O ultra-som pulsado no período de pré-implantação não alterou os fetos, mas as ondas contínuas induziram aumento do peso relativo do coração, fígado, dos pulmões e rins. No período de implantação, o ultra-som pulsado causou diminuição do peso da placenta, e as ondas contínuas acarretaram aumento do peso absoluto do cérebro e do coração fetais. / Therapeutic ultrasound is widely used in different aesthetic treatment by young women, who can be irradiated during early gestation. Researches regarding the effects of therapeutic ultrasound on gestation present controversial results. Methodologies incompatible with clinical aspects are used and different methods and technics were employed. However none of them were reproduced in two similar works and only a few observed the early gestation, period when pregnancy is commonly unnoticed. The ultrasound causes increased cell membrane permeability, alterations in ionic diffusion, vasodilation; modifies the intra and extracellular particles position and alter the normal configuration of cells, leading to functional alterations. During early embryo development, cells depend upon protein synthesis and on sinalizations triggered by sodium and potassium channels. Furthermore the participation of microtubules and microfilaments on morphogenesis are extremely important. All this indicates the exposition to ultrasound could cause lesions on the conceptus. In the present work the effects of therapeutic ultrasound with pulsed and continous waves during early pregnancy of the rat were assesed. The methodology consisted in rats exposition to ultrasound in two periods: preimplantion (groups A1, A2 and A3) and implantation (groups B1, B2 and B3). The animals were sedated and exposed to therapeutic ultrasound, frequence of 3 MHz, intensity of 0.6 W/cm2 (SATA), during five minutes. Groups A1 and B1 received pulsed waves, groups A2 and B2 received continuous waves whereas the groups A3 and B3 were sham-exposed. The rats were euthanatized by an overdose of anesthesic 20 days after insemination. The hematocrit, hemoglobin, total leukocytes, and the level of aspartate aminotransferases, alanine transaminase, cholesterol, triglycerides and creatinine were analysed. The dams underwent authopsy for the identification of lesions in the internal organs and removal and weghing of the liver, kidneys and ovaries. The number of resorptions, live, dead and malformed fetuses were counted. The fetal brain, lungs, liver, kidneys and placentae were weighed. The data were processed using the one-way analysis of variance (ANOVA) followed by Dunnett's test. Non parametric data were analyse using the Chi-Square or Kruskal-Wallis tests. The null hyphotesis was reject when p< 0.05. No alterarions were detected on body and maternal organs’ weights, and reproductive performance. The relative weights of heart, liver, kidneys and lungs were higher in group A2. Heart and brain were heavier in group B2, and the weight of placentae decreased in group B1. In conclusion, in the experimental model used, the ultrasound showed no toxic effects on the maternal organism, except for the increased triglyceride levels. The pulsed -wave ultrasound presented no fetal toxic effects on the preimplantation period, but the continuous waves induced an increase on the relative weights of heart, liver, kidneys and lungs. During the implantation period, the pulsedwave ultrasound caused a decrease in placentae weights, and the continuous waves induced an increased on the aboslute weights of fetal brain and heart.
170

Influência do ultra-som na resistência à abrasão e na rugosidade de superfície dos cimentos de ionômero de vidro submetidos à escovação / Influence of the ultrasound in the abrasion resistance and in superficial roughness of the glass ionomer cements submitted to toothbrush

Renata Loureiro Louro 30 March 2007 (has links)
O objetivo deste estudo foi avaliar o desgaste à abrasão decorrente da escovação simulada de cimentos de ionômero de vidro sonificados, por análise da alteração de massa e da textura superficial. Os materiais avaliados foram: Fuji II LC (GC América), Resiglass (Biodinâmica), Vitro Fil LC (DFL), Fuji IX (GC América), Ketac Molar (3M ESPE), Vitro Molar (DFL), Bioglass (Biodinâmica), Vitro Fil (DFL), que foram manipulados conforme instruções do fabricante, constituindo-se no grupo controle, e um grupo submetido ao ultra-som EMS FT-081 DN Mini PIEZON (EMS, Nyon, Geneva, Switzerland), constituindo-se no grupo experimental. Os corpos-deprova foram confeccionados em uma matriz de dente bovino, com um orifício central com dimensões de 5mm de diâmetro e 3mm de espessura. Foram confeccionados 10 corpos-de-prova para cada material e cada grupo (experimental e controle). O teste de simulação da escovação foi realizado numa máquina automática para simulação de escovação (M.N. São Carlos - Brasil). A alteração de massa foi verificada pela diferença entre a massa inicial (antes da escovação) e final (após a escovação), em balança de precisão (cap. 210g, sens. 0,0001g mod. Mark 210A LICiT-Bel/Proc. Italian), com precisão de quatro casas decimais. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 (Hommelwerke, GmbH, Alte Tuttinger Strebe 20. D-7730 VS-Schwenningen). Os resultados obtidos foram submetidos à análise de ANOVA a dois critérios e Tukey (p<0,05). Quanto à perda de massa não houve diferença estatisticamente significante em relação à aplicação do ultra-som (p=0,403). No entanto, houve diferença estatisticamente significante para os diferentes Ionômeros estudados, onde p<0,001, mais precisamente do Resiglass e do Vitro Molar com os demais materiais. No que se refere à alteração de rugosidade houve diferença estatisticamente significante para a condição utilização ou não do ultra-som (p=0,043), mas não para os diferentes materiais estudados, onde p=0,264. A excitação ultra-sônica durante a presa inicial piora a rugosidade de superfície e não apresenta nenhuma influência na perda de peso. / The purpose of this work was to evaluate abrasion resistance, by means of weight loss, and surface roughness (SR) of GIC, using ultrasonic excitation as a command set. The materials tested were Fuji II LC and Fuji IX (GC Corporation), Ketac Molar (3M ESPE), Resiglass and Bioglass (Biodinâmica), Vitro Fil LC, Vitro Molar and Vitro Fil (DFL). Twenty specimens of each GIC brand were evaluated, being half submitted to ultrasound (US) (Piezon - EMS, Switzerland). The materials were placed in bovine tooth matrix (5mm inner diameter and 3mm of thickness). Initial weight was carried out by means of a digital balance (210A LICiT/Italian). The initial SR was quantitatively assessed by measuring the surface roughness using Hommel Tester T1000 (Hommelwerke, Germany) determined by the average of 5 random measurements in each sample. The specimens were submitted to brushing abrasion test. Weight loss and surface roughness, for each specimen were calculated based on the difference between the initial and final weight and surface roughness means, respectively. Weight loss (g) varied between 0,0001 and 0,0090 with US and 0,0001 and 0,0123 without US. Surface roughness (µm) varied between 0,0770 and 0,4330 with US and -0,0270 and 0,3520 without US. The results, analyzed by two way ANOVA and Tukey\'s test (p<0,05), presented statistically significant difference in the surface roughness when the GIC was submitted or not to US (p=0,043) while no statistical difference was observed among the GIC brands (p=0,264). The weight loss presented statistically significant difference between the tested GIC brands (p<0,010), while no influence on the weight loss by the use of US was observed (p=0,403). Ultrasonic excitation during initial cure does not improve surface roughness of GIC, and does not present any influence on weight loss.

Page generated in 0.0532 seconds