• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Efeito solvente orgânicos e ultrassom na remação de bráquetes ortodônticos / Regis Meller Santana ; orientador, Orlando Tanaka ; coorientador, Rodrigo Nunes Rached

Santana, Regis Meller January 2012 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Inclui bibliografias / Objetivos: Avaliar o efeito de géis de solventes orgânicos (acetona 70% e etanol 90%) e de ultrassom na remoção de bráquetes metálicos. Materiais e Métodos: Bráquetes metálicos foram colados com compósito ortodôntico fotopolimerizável (Transbond XT) em 12 / Introduction: To evaluate the effect of organic gel solvents (70% acetone and 90%ethanol) and of ultrasound in the removal of metallic brackets. Methods: Metallic brackets were bonded with light-cured orthodontic composite (Transbond XT) in 120 human bicu
142

Multiferróicos monofásicos a base de Pb(Fe2/3W1/3)O3-PbTiO3: acoplamento magnetoelétrico intrínseco

Fraygola, Bárbara Maraston 25 November 2010 (has links)
Made available in DSpace on 2016-06-02T20:15:22Z (GMT). No. of bitstreams: 1 3342.pdf: 5504646 bytes, checksum: c4f8ff5e8dec83b3c337cd77e6a5f8fd (MD5) Previous issue date: 2010-11-25 / Universidade Federal de Minas Gerais / Multiferroic ceramic solid solutions between the ferroelectric relaxor Pb(Fe2/3W1/3)O3 (PFW) and normal ferroelectric PbTiO3 (PT) [PFW-PT] has been synthesized by a modified B-site precursor method and characterized by X-ray diffraction, differential thermal analysis, dielectric, electric, magnetic and anelastic measurements. A two-stage solid-state reaction turned out to be appropriate for the formation of the majoritary PFW phase as well as PFW-PT solid solutions, with low percentage of spurious phases, high densities, dielectric constant and electric resistivities. Intrinsic relationship between structure, composition, magnetic ordering and dielectric proprieties was discussed. Dielectric properties have been tailored by adding PbTiO3, bringing the ferroelectric transition toward the room temperature, transforming the phase transition from diffuse, typical for ferroelectric relaxors, to a sharp one, characteristic of normal ferroelectrics. Two types of superexchange magnetic interactions and a succession of magnetic transitions with Neel temperatures dependent on the composition were found in the solid solutions. The magnetic ordering at TN1 is expected to vanish with PT addition, for higher amounts of PT to 30 percent. For 12-13%PT, the samples are multiferroic (presenting ferroelectric and antiferromagnetic ordering) below 237K. Anomalies in the temperature dependence of the elastic constants have been observed at TN and TC for all samples, indicating that the magnetoelectric coupling between the ferroelectric and antiferromagnetic orders occurs via strain . The value of the magnetoelectric coefficients η were estimated for all samples, from the measured values of their magnetic susceptibility, dielectric constant, magnetoelastic and electroelastic coefficients. Additionally, an interplay between ferroelectric and ferromagnetic properties of the samples, as well as the influence of the proximity of the temperatures of the establishment of both orderings with intrinsic magnetoelectric coupling coefficient was established. / Ceramicas multiferroicas da solucao solida entre o relaxor Pb (Fe2/3W1/3) O3 (PFW) e o ferroeletrico normal PbTiO3 (PT) [PFW-PT] foram sintetizadas pelo metodo do sitio B modificado e caracterizadas por difracao de raios X , analise termica diferencial, medidas dieletricas, eletricas, ferroeletricas, magneticas e anelasticas. Este metodo resultou adequado para a formacao da fase pura das ceramicas de PFW assim como da solucao solida com PT, com baixissima porcentagem de fases espurias, altas densidades, altas constantes dieletricas e altas resistividades. A adicao de PT aumenta a temperatura de transicao ferroeletrica do PFW puro , levando a amostra de uma transicao com caracteristicas relaxoras (Tc~180K para as amostras de PFW) para uma transicao normal (Tc~320K para as amostras de PFW-30PT). Dois tipos de interacoes magneticas (antiferromagnetica e ferromagnetica fraca) com temperaturas dependentes da composicao foram encontrados na solucao solida. A temperatura de ordenamento antiferromagnetico em TN1 (~350K para o PFW puro) desaparece com a adicao PT, enquanto que a temperatura de transicao a baixas temperaturas (~10K para o PFW puro) aumenta com a adicao de PT ao sistema. Para 12-13% PT, as amostras sao multiferroicas (com ordenamentos ferroeletrico e antiferromagnetico) abaixo de 237K. As relacoes entre a estrutura, composicao, ordenamento magnetico e propriedades dieletricas foram discutidas. Anomalias na dependencia com a temperatura das constantes elasticas foram observadas em TN e TC para todas as amostras, indicando que o acoplamento magnetoeletrico ocorre vai strain . O valor do coeficiente magnetoeletrico intrinseco η foi estimado para todas as amostras, a partir dos valores medidos de susceptibilidade magnetica, constantes dieletricas, coeficientes magnetoelasticos e eletroelasticos. Adicionalmente, uma interrelacao entre as propriedades ferroeletricas e ferromagneticas das amostras, assim como da influencia da proximidade das temperaturas de estabelecimento de ambos os ordenamentos com o coeficiente de acoplamento magnetoeletrico intrinseco foi estabelecida.
143

Caracterização elétrica, dielétrica e anelástica de transições de fase em cerâmicas de Pb (Fe1/2Nb1/2)O3

Fraygola, Bárbara Maraston 20 September 2007 (has links)
Made available in DSpace on 2016-06-02T20:16:42Z (GMT). No. of bitstreams: 1 1700.pdf: 3329271 bytes, checksum: ced6b5fbac85d5a15900ad128f39d9a6 (MD5) Previous issue date: 2007-09-20 / Financiadora de Estudos e Projetos / El Niobato de plomo y hierro Pb(Fe1/2Nb1/2)O3 es un material multiferroico: es ferroeléctrico a temperaturas inferiores a 383K y antiferromagnético a temperaturas inferiores a 143K, presentando propiedades magnetoelétricas abajo de esta temperatura. Existen en la literatura controversias en cuanto al número de transiciones de fases para este material, y en particularmente, sobre la existencia de dos transiciones entre fases ferroeléctricas entre la temperatura de Curie y 250K. En este trabajo fueran medidas la atenuación y la velocidad ultrasónicas, la resistividad eléctrica, el coeficiente piroeléctrico y la permisividad dielétrica en cerámicas de PFN. Las medidas inelásticas presentan anomalías a 353K, 315K, 250K e 172K que pueden asociarse a la transición para-ferroeléctrica, a las dos transiciones de fases entre fases ferroeléctricas propuestas en la literatura, y a la transición para-antiferromagnética. La permisividad dieléctrica solamente registra anomalías en la región de transición para-ferroeléctrica, mientras que el coeficiente piroeléctrico registra el mismo comportamiento que el observado para las constantes elásticas. A través de medidas eléctricas observamos un cambio en la energía de activación alrededor de la temperatura de ordenamiento magnético, mostrando a altas temperaturas un comportamiento diferenciado para muestras sinterizadas por caminos distintos. Correlacionando los resultados en la región de transición de fase paraantiferromagnética proponemos que el acoplamento magnetoelétrico envuelve necesariamente contribuciones elásticas (acoplamiento via strain). Proponemos además que este acoplamiento entre la magnetización y el strain es del tipo piezomagnético. La diferencia en temperaturas en anomalías correspondientes a la transición para-antiferromagnética obtenidas experimentalmente con la temperatura de Neél está prevista en la literatura y está asociada al desorden en la red cristalina. Esta dependencia con el desorden fue comprobada al obtener-se anomalías a temperaturas diferentes en la región de ordenamiento magnético para muestras tratadas térmicamente en atmósfera oxidante. Encontramos una anomalía adicional a 115K, ya reportada anteriormente en medidas magnéticas, asociadas a una nueva transición debida a la interacción magnetoeléctrica. / O Niobato de Ferro e Chumbo 3 2 / 1 2 / 1 ) ( O Nb Fe Pb (PFN) é um material multiferróico: é ferroelétrico a temperatura inferiores a 383K e antiferromagnético a temperaturas inferiores a 143K e apresenta propriedades magnetoelétricas abaixo desta temperatura. Existem também na literatura controvérsias quanto ao número de transições de fase e, particularmente sobre a existência de duas transições de fases entre fases ferroelétricas entre a temperatura de Curie e 250K. Neste trabalho foram medidas a atenuação e a velocidade ultra-sônicas,a resistividade elétrica, o coeficiente piroelétrico e a permissividade dielétrica em cerâmicas de PFN. As medidas anelásticas apresentam anomalias a 353K, 315K, 250K e 172K que podem associar-se á transição para-ferroelétrica, ás duas transições de fase entre fases ferroelétricas propostas na literatura, e á transição para-antiferromagnética. A permissividade dielétrica somente registra anomalias na região de transição para-ferroelétrica, enquanto que o coeficiente piroelétrico registra o mesmo comportamento que as constantes elásticas. Através de medidas elétricas observamos uma mudança na energia de ativação em torno da temperatura de ordenamento magnético, apresentandose a altas temperaturas um comportamento diferenciado para as amostras sinterizadas por vias e temperaturas diferentes. Correlacionando os resultados na região de transição de fase paraantiferromagnética propomos que o acoplamento magnetoelétrico envolve necessariamente contribuições elásticas (via strain). Propomos que o acoplamento entre a magnetização e o strain é um acoplamento do tipo piezomagnético. A diferença em temperatura das anomalias correspondentes a transição paraantiferromagnética obtidas experimentalmente com a temperatura de Neél está prevista na literatura e está associada ao desordem na rede cristalina. Esta dependência foi comprovada ao obter-se anomalias a temperaturas diferentes na região de ordenamento magnético para amostras tratadas termicamente em atmosfera oxidante. Encontramos uma anomalia adicional a 115K, já reportada anteriormente em medidas magnéticas, associada a uma nova transição devida à interação magnetoelétrica.
144

Construção e caracterização do campo acústico de transdutores ultra-sônico piezoelétrico de polarização variável

Moreira, Danilo Conti 23 October 2008 (has links)
Made available in DSpace on 2016-06-02T20:16:44Z (GMT). No. of bitstreams: 1 2172.pdf: 3848393 bytes, checksum: 7a8baaabd76fb4d68c01f2456a6427ab (MD5) Previous issue date: 2008-10-23 / Universidade Federal de Sao Carlos / This work was motivated on the great technological and commercial interest of ultrasonic transducer, capable to generate diffraction controlled ultrasonic beams in the frequency range of kHz up to MHz. As a solution, in this work we proposed the construction of Bessel-like transducers, which have the polarization of the piezoelectric constituent element with a Bessel function profile. As a comparative result, conventional transducers were also built. The conventional modes of vibration, thickness and radial, were characterized, aiming to estimate the potential of these transducers for applications in diagnosis, such as: non-destructive tests or medicalultrasonography. The transducers were based on a poled niobium doped PZT ferroelectric ceramics, with disk shape. The polarization profile, of the concentric electroded rings, of the Bessel-like transducer followed the Bessel function (Jo) profile. The characterizations were based on electromechanical and acoustics techniques for the emission, reception and emissionreception (pulse-echo) modes. To the acoustic characterizations (acoustic field) transducers receivers (hydrophones) were also constructed and calibrated as a function of the frequency, to present a linear response in the frequency range for each transducer. The electromechanical characterization provided the impedance spectrum of the vibration modes, and their respective harmonics, for the transmitters and receivers transducers. The characterization of the transducers acoustic field, for both modes, thickness and radial, has shown that on the Bessel-like transducers the diffraction of the central beam can be controlled and/or reduced, if compared with the conventional, or uniform poled transducer. However, the experimental verification of radial mode pattern of the conventional transducer (in the fundamental mode or in each of its harmonics), showed a natural Bessellike transducer behavior, with a typical Bessel polarization profile. Exploring the radial mode can provide a lower frequency of operation (if compared with the thickness mode), allowing one increase of the penetration depth, besides a decreasing on the ultrasound Rayleigh beam distance, with good collimation and good resolutions. The results of this study shown that ultrasonic transducer with non uniform polarization pattern, especially those of Bessel type, are promising materials for applications in ultrasonic piezoelectric transducers, exploring as well the radial mode as the thickness vibration modes. / O desenvolvimento deste trabalho foi motivado pela necessidade do mercado em transdutores ultra-sônicos, capazes de gerar feixes ultra-sônicos com difração controlada, para se trabalhar com freqüências tanto da ordem de kHz quanto na faixa dos MHz. Uma solução encontrada para suprir essa carência foi a construção de transdutores do tipo Bessel , em que a polarização do elemento piezoelétrico apresenta um perfil que segue uma função de Bessel. Neste trabalho foram construídos e caracterizados transdutores ultra-sônicos do tipo Bessel e convencional, para os modos de vibração espessura e radial, visando estimar o potencial dos transdutores para aplicações em diagnose (ensaios não destrutivos ou ultrasonografia em medicina). Construiu-se um transdutor utilizando discos cerâmicos ferroelétricos de PZT dopado com nióbio, com polarização uniforme e outro com polarização variável. O perfil da polarização não uniforme seguiu o perfil de uma função de Bessel (Jo), em anéis concêntricos pintados nas faces da cerâmica. Os transdutores construídos foram caracterizados pelas técnicas eletromecânica e acústica, em regime de emissão, recepção e de emissão-recepção (pulso-eco). Para as caracterizações de campo acústico transdutores receptores (hidrofones) foram construídos e adequados para obter boa linearidade nas freqüências de operação dos transdutores. A caracterização eletromecânica forneceu o espectro de impedância para os modos de vibração e seus respectivos harmônicos dos transdutores emissores e receptores. A caracterização do campo acústico dos transdutores, tanto para o modo de espessura quanto radial, permitiu verificar que os transdutores Bessel permitem diminuir ou controlar a difração do lóbulo central, quando comparados a um transdutor com polarização convencional ou uniforme do elemento piezoelétrico Relevante, todavia foi a verificação experimental de que transdutor convencional, quando excitado no modo radial (no modo fundamental ou em um dos seus harmônicos), comporta-se como um transdutor Bessel natural , assumindo naturalmente as características condizentes a esse perfil de polarização. A excitação no modo radial pode proporcionar uma freqüência de operação inferior (àquela do modo de espessura), aumentando a profundidade de penetração e diminuindo a distância de Rayleigh do feixe ultra-sônico, com boa colimação e boas resoluções. Os resultados decorrentes deste trabalho evidenciam claramente que transdutores ultra-sônicos com polarização não uniforme, em particular os do tipo Bessel, apresentam potencial para utilização em transdutores ultra-sônicos piezoelétricos com difração controlada, que explorem tanto o modo de vibração radial quanto o de espessura do elemento piezoelétrico.
145

Avaliação do método de propagação da onda ultrassônica na determinação da profundidade de fissura em concreto

Glauber Beirão de Souza 13 December 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os avanços conseguidos no Brasil na qualidade das estruturas de concreto armado foram significantes a partir de 2003, quando a NBR 6118 (Projeto de Estrutura de Concreto Procedimento) passou a considerar a Durabilidade como parâmetro e assim estabelecer os requisitos básicos exigíveis para o projeto de estruturas de concreto simples, armado e protendido. As estruturas de concreto armado passaram a ser projetadas tendo em vista a necessidade de atender não somente a estabilidade estrutural, mas também ao caráter de durabilidade, um requisito fundamental e imprescindível para a viabilidade da solução estrutural. Procedimentos de execução e aplicação dos concretos ineficazes tornam inevitáveis o surgimento das fissuras tornando-as frequentes. Avaliar as fissuras no concreto através de técnicas não destrutíveis está sendo cada vez mais comum no âmbito da engenharia de avaliações. Este trabalho se propõe a estudar a utilização do ultrassom, ensaio não destrutível, na avaliação das fissuras superficiais e suas profundidades, ferramenta que possibilita ao engenheiro avaliar o concreto e realizar previsões de sua vida útil. Para isso os experimentos foram realizados em laboratório. Foram utilizados corpos de prova prismáticos com fissuras de 3,3 cm, 4,4 cm, 9,1 cm e 10,5 cm de profundidade avaliados pelos modelos de Bungey (1989), BS EM 12504-4 (2004) e Bungey (1989) adaptado pelo autor. / The advances made in Brazil in the quality of reinforced concrete structures were significant since 2003, when NBR 6118 - (Concrete Structure Project - Procedure) started to consider Durability as a parameter and thus to establish the basic required requirements for the project Of simple, reinforced and prestressed concrete structures. Reinforced concrete structures are now designed to meet not only structural stability but also durability, a fundamental and indispensable requirement for the viability of the structural solution. Procedures for the execution and application of ineffective concretes make it inevitable that cracks will emerge making them frequent. Evaluating cracks in concrete through non-destructible techniques is becoming increasingly common in engineering appraisals. This work intends to study the use of ultrasound, a non-destructible test, in the evaluation of surface cracks and their depths, a tool that allows the engineer to evaluate the concrete and make predictions of its useful life. For this the experiments were carried out in the laboratory. The prismatic specimens with cracks of 3.3 cm, 4,4 cm, 9,1 cm and 10,5 cm of depth were evaluated using the Bungey (1989), BS EM 12504-4 (2004) and Bungey ( 1989) adapted by the author.
146

Efeito do ultra-som pulsado de baixa intensidade sobre fêmur de ratas ovariectomizadas.

Albertin, Lucélia Maria 16 August 2007 (has links)
Made available in DSpace on 2016-06-02T19:22:01Z (GMT). No. of bitstreams: 1 TeseLMA.pdf: 1012618 bytes, checksum: 882e8e832674ec1fc042027fce7b4959 (MD5) Previous issue date: 2007-08-16 / Universidade Federal de Sao Carlos / Osteoporosis is a metabolic disease characterized by the damage of the bone strength due to the integration of bone density, expressed by the quantity of mineral material by bone area and volume, and the bone quality related to bone architecture, remodeling and mineralization. It is a disease that induces bone fragility and fracture spinal column and in the femur, where trabecular bone are predominant. The osteoporotic fractures are responsible by great morbidity and mortality, therefore representing a great public health problem. Studies with alternative non pharmacological treatments have been proposed and one of them is the pulsed ultrasound with low intensity (US). It is well known its osteogenic effect as a mechanical stimulus in isolates cells and bone fractures. However, these effects are not completely explained in the osteoporosis. Also, studies with aim to avoid the osteopenia with mechanical stimulus as US are rare. Therefore, the present study had the objective to analyze the effect of US (30 mw/cm2 SATA, 200µs pulse width, 1 KHz of frequency of repetition and frequency of 1.5 MHz) in femur of rats. The ovariectomized Wistar rats were used as animal model of experimental osteoporosis. Biomechanical, physical and histomorphometric parameters were analyzed. The treatment began 24h after ovariectomy, 5 days/week, during 8 weeks. Female rats with 4 months of age were divides in 6 experimental groups: US 30 and US 20 - OVX rats US stimulated during 30 and 20 minutes; Sham 30 and Sham 20 OVX rats US sham stimulated; Intact 30 and Intact20 intact rats US sham stimulated. The efficacy of the osteopenia model induced by ovariectomy was demonstrated by the physical, biomechanical and histomorphometric parameters. These parameters also showed that US was not efficiency to avoid the bone microarchiteture deterioration induced by castration. / A osteoporose é uma doença metabólica que se caracteriza pelo comprometimento da resistência óssea, conseqüência da integração de dois fatores: a densidade óssea expressa pela quantidade de material mineral por área ou volume ósseo e a qualidade óssea relativa a arquitetura, remodelamento e mineralização óssea com conseqüente aumento da fragilidade óssea e susceptibilidade a fraturas. As fraturas osteoporóticas são freqüentes no punho, na coluna tóraco-lombar e no fêmur, isto é, em áreas do esqueleto com predomínio de osso trabecular. Elas determinam grande morbidade e mortalidade, com repercusões sócioeconômicas, sendo assim um grande problema de saúde pública. Estudos têm sido elaborados propondo tratamentos alternativos, não farmacológicos, dentre eles o ultra-som pulsado de baixa intensidade que já tem estabelecido seu efeito osteogênico, como estímulo mecânico, em células isoladas e fraturas ósseas. Porém, em osteoporose estes efeitos não estão totalmente esclarecidos, como também são escassos os estudos com o objetivo de evitar a osteopenia através de estímulos mecânicos tais como o ultra-som. Para tanto, o presente estudo teve como objetivo analisar a atuação do ultra-som pulsado de baixa intensidade (30mw/cm2- SATA, largura de pulso de 200µs, freqüência de repetição e 1,0 KHz e freqüência de 1,5 MHz) em fêmur de ratas Wistar ovariectomizadas (OVX), utilizadas como modelo de osteoporose experimental, através da análise de parâmetros biomecânicos, físicos e histomorfométricos. O tratamento iniciou 24 h após a ovariectomia por 5 dias/semana com a duração de 30 e 20 minutos durante 8 semanas. Ratas Wistar com 4 meses de idade foram divididas em 6 grupos experimentais: Grupos US 30 e US 20 ratas OVX que receberam estimulação ultrassônica durante 30 e 20min. respectivamente; Grupo Sham 30 e Sham 20 ratas OVX estimuladas por 30 e 20 min. respectivamente porém, com o aparelho de ultra-som desligado; Grupo Intacto 30 e Intacto 20 ratas não ovariectomizadas, estimuladas por 30 e 20 min respectivemente, com o aparelho de ultra-som desligado. A eficácia do modelo de osteopenia induzida pela ovariectomia ficou demonstrada através da análise das propriedades biomecânicas, físicas e histomorfométricas. Esta investigação evidenciou também a não atuação do ultra-som pulsado de baixa intensidade evitando mudanças da microarquitetura dos ossos osteopênicos.
147

EFEITO DO ULTRA-SOM NA ATIVIDADE DE ENZIMAS AMILOLÍTICAS E SOBRE A EFICIÊNCIA DE HIDRÓLISE DE AMIDO DE MANDIOCA / EFFECT OF ULTRASOUND IN AMYLOLYTIC ENZYMES ACTIVITY AND ON EFFICIENCY OF HYDROLYSIS OF CASSAVA STARCH

Leães, Eloisa Xavier 27 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Ethanol production from cassava undergoes two-stage hydrolysis and fermentation. The starch hydrolysis may be made of acidic or enzymatic way, the latter presents the greatest advantages. In the production of starch hydrolysates by enzymatic conversion enzymes represent a high cost, so the study of new technologies aimed at increasing the efficiency of amylolytic enzymes is of paramount importance to reduce process costs. This study aimed to evaluate the influence of ultrasound on enzymatic hydrolysis of cassava fresh and characterization of the enzymes α-amylase (Liquozyme® SC DS) and glucoamylase (Spirizyme® Fuel) used in the reactions. We determined the temperature and optimum pH, kinetic parameters and thermal stability of enzymes by the hydrolysis of soluble starch, using a water bath and ultrasonic bath. Results showed a small increase in enzyme activities when treated individually during the experiments with ultrasound compared to those made only with the bath under the same conditions of temperature and pH at the time of 30 minutes. The hydrolysis reactions of fresh cassava with both enzymes simultaneously, showed that the use of ultrasound caused a significant increase in the release of total reducing sugars, 24.64 to 64.48% higher compared to the conventional method used in the temperature conditons of 55°C, pH 5.5, and equal amounts of substrate and enzymes. This way the use of ultrasound may reduce the cost of ethanol production using cassava as a carbohydrate source, and a promising technology to be used. / A produção de etanol a partir de mandioca passa por duas fases, a hidrólise e a fermentação. A hidrólise do amido pode ser feita de forma ácida ou enzimática, sendo a última a que apresenta maiores vantagens. Na produção de hidrolisados de amido por conversão enzimática as enzimas representam um alto custo, portanto o estudo de novas tecnologias visando o aumento da eficiência das enzimas amilolíticas é de suma importância para redução de custos do processo. Este trabalho objetivou a avaliação da influência do ultra-som na hidrólise enzimática de mandioca in natura e a caracterização das enzimas α-amilase (Liquozyme® SC DS) e glicoamilase (Spirizyme® Fuel) utilizadas nas reações. Foram determinadas a temperatura e pH ótimo, parâmetros cinéticos e termo-estabilidade das enzimas através de reações de hidrólise de amido solúvel comercial, com utilização de banho-maria e banho de ultra-som. Os resultados mostraram um pequeno aumento nas atividades das enzimas quando tratadas individualmente durante os experimentos com ultra-som em relação aos realizados somente com o banho-maria, nas mesmas condições de temperatura e pH, no tempo de 30 minutos. Já as reações de hidrólise da mandioca in natura com as duas enzimas simultaneamente, mostraram que o uso do ultra-som provocou um aumento significativo na liberação de açúcares redutores totais, de 24,64 a 64,48% maior em relação ao método convencional utilizado, nas condições de temperatura 550C, pH 5,5 e mesmas quantidades de substrato e enzimas. Desta forma o uso do ultra-som pode reduzir os custos de produção de etanol utilizando-se a mandioca como fonte de carboidratos, sendo uma tecnologia promissora a ser utilizada.
148

Avaliação radiográfica e ultra-sonográfica do aparato podotroclear dos cavalos da raça Quarto de Milha acometidos pela síndrome do navicular

Peixoto, Cintia Iolanda Coutinho [UNESP] 12 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-12Bitstream added on 2014-06-13T18:58:44Z : No. of bitstreams: 1 peixoto_cic_me_botfmvz.pdf: 358514 bytes, checksum: 57b69ef642aa731df448cd7ffc6de07f (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo deste estudo foi avaliar as alterações do aparato podotroclear dos cavalos da raça Quarto de Milha acometidos pela doença do navicular utilizando o acesso transcuneal. Foram utilizados 22 animais oriundos da região de Botucatu e Bauru-SP. Estes animais foram submetidos ao exame radiográfico e ultra-sonográfico. No exame radiográfico foi observada a presença de invaginação sinovial de diferentes tipos, além calcificação da bursa podotroclear e tendão flexor digital profundo, entesiófitos, osteófitos e alteração do limite córtico-medular. No exame ultra-sonográfico observou-se alterações da bursa podotroclear, aderência e irregularidades nos bordos do tendão flexor digital profundo, diminuição do coxim digital, calcificação do ligamento sesamóide distal ímpar e irregularidade da superfície flexora do osso sesamóide distal. Todos os animais que apresentavam alteração radiográfica e também apresentaram alteração no exame ultra-sonográfico compatível com a doença do navicular. O exame ultra-sonográfico utilizando o acesso transcuneal foi um método prático e eficiente para avaliação das lesões do aparato podotroclear dos eqüinos, sendo um método complementar ao exame radiográfico. / The objective of this study was to evaluate the podotrochlear apparatus using a transcuneal approach in American Quarter horses suffering from navicular disease. 22 horses from the area of Botucatu and Bauru in São Paulo were evaluated. On those patients, radiographic and ultrasonographic evaluations were performed. On radiograph, different kinds of synovial invaginations, calcifications of the podotrochlear bursa and deep digital flexor tendon, enthesiophytes, osteophytes, and alterations in the cortical-medullary margin were observed. On the ultrasound scans, alterations of the podotrochlear bursa, adherences and irregularities at the surface of the deep digital flexor tendon, diminution of the digital cushion, calcifications of the impar distal sesamoideal ligament, and irregularities of the flexor surface of the distal sesamoid bone were observed. Radiographic and ultrasonographic alterations compatible with navicular disease were present in all of the patients. Ultrasonography using transcuneal approach was a practical and efficient method for evaluating podotrochlear apparatus injuries in equine, thus being a complementary method to radiography.
149

Avaliação de parâmetros ultra-sônicos utilizados na caracterização de tecidos ósseos / Assessment of Ultrasonics Parameters Utility in Customization of Bone Tissues.

Paulo Sérgio de Matos 27 July 2006 (has links)
A transmissão do ultra-som no organismo humano tem sido objeto de estudos a várias décadas, com a finalidade de promover diagnóstico. Recentemente tem sido usada para avaliar a densidade óssea e poder diagnosticar precocemente o aparecimento da osteoporose e prever o risco de fratura. Nesse trabalho foi desenvolvido um sistema capaz de gerar, receber e amplificar sinais ultra-sônicos para a avaliação da velocidade do som e atenuação em função da freqüência (BUA). A técnica usada foi a de transmissão do sinal ultra-sônico, com acoplamento por gel de ultra-som e por água (tanque acústico), que consiste no uso de dois transdutores, um para transmissão e outro para recepção, sendo a amostra posicionada entre eles. Devido ao alto índice de dispersão nas medidas ultra-sônicas, será buscado um material de referência, o qual deve possuir características tanto de velocidade do som e atenuação em função da freqüência, parecidas com a do osso (calcâneo), que será usado para calibração do equipamento e para o acompanhamento da medida óssea. Foram utilizados os parâmetros ultra-sônicos para avaliação da consolidação óssea (em tíbias de carneiro) em diferentes períodos e nos diversos tipos de fraturas. O sistema foi caracterizado em termos de temperatura e reprodutibilidade utilizando diferentes materiais. Medidas no calcâneo de voluntários, de velocidade e atenuação em função da freqüência, independente de associações patológicas, mostrou resultados compatíveis com os encontrados na literatura. Foram feitas diversas análises, com pequenas mudanças nas condições geométricas, de sinal e freqüência dos transdutores, para observar sua influência sobre as medidas de atenuação e velocidade. Isto com a finalidade de tentar relacionar as variações nas medidas de atenuação obtidas por diferentes autores. / Ultrasound transmission in human bodies has been studied for several decades in order to facilitate diagnosis. It has also been used to evaluate bone density and to diagnose early osteoporosis and future fracture risks. For this study, a system to generate, receive and amplify ultrasonic signs for speed of sound assessment and broad band ultrasound attenuation (BUA) was developed. Transmission of ultrasonic signals was performed by coupling using ultrasound gel and water (acoustic tank) and the sample placed between two transducers, one for transmission and the other for reception. Due to the high rate of the dispersion of ultrasonic measures, some reference material having the characteristics of the speed of sound and broad band ultrasound attenuation, similar to the heel bone that will be used for equipment calibration and follow-up of bone measure will have to be found. Ultrasonic parameters were used to evaluate bone consolidation (tibia of a sheep), in different periods and several kinds of fractures. Temperature and reproducibility using different materials were used to customize the system. Measures of volunteers\'s heel bone speed and broad band ultrasound attenuation showed results consistent with the ones from literature. Several analyses with little changes in geometric, signal and transducer frequency conditions were performed in order to observe their influence on attenuation and speed measures. Those steps were carried out in order to try to relate the variations in attenuation measures to those obtained by other authors.
150

Desenvolvimento de um \"phantom\" para treinamento de biopsia de mama guiada por ultra-som / Phantom for Breast Biopsy Training Guided by Ultrasound

Silvio Leão Vieira 09 September 2005 (has links)
Neste estudo foi realizada a caracterização das propriedades acústicas e a construção de um protótipo de phantom de mama para treinamento de biópsia guiada por ultra-som. Uma importante propriedade deste phantom é a capacidade de ser reconstruído termicamente após ter sido perfurado durante treinamento e/ou sofrido algum dano mecânico. Para tanto, foi desenvolvido um sistema de reciclagem especialmente para o phantom. Dentre os materiais avaliados, a parafina gel apresentou-se estável, nas condições experimentais propostas, tais como, temperatura ambiente entre 22 e 26oC, densidade de 0,85 g/cm3 para a amostra com concentração de 4%, a qual é inferior a do tecido mole ( 1g/cm 3), sendo então empregada em estudos seguintes. O material simulando tecido foi obtido adicionando microestrutura espalhadora (pó de vidro) à substância parafina gel. A caracterização do material foi realizada por duas técnicas de medidas acústicas; a primeira usando o modo amplitude (modo-A) e a segunda o modo brilho (modo-B). O coeficiente de atenuação, para o modo-A, observado para este material, numa faixa de freqüência dos ultra-sons diagnósticos (entre 1 e 10 MHz) foi de 0,75 dB/cm/MHz, equivalente ao indicado pela literatura para tecido biológico mole. A velocidade do som avaliada foi de 1431,2 m/s a uma temperatura de 22oC. Esse valor de velocidade está abaixo da velocidade média do tecido mamário, que é de 1510 m/s, estando mais próximo daquele encontrado para a gordura, 1470 m/s. A atenuação no modo brilho foi estudada comparando-se as diversas atenuações relativas das imagens fornecidas pelas amostras, estando inversamente correlacionadas com a atenuação encontrada no modo amplitude. A velocidade do som também foi avaliada por essa técnica obtendo-se um valor médio de 1416,1 m/s para as amostras estudadas. Partículas espalhadoras sólidas de 45 - 75 µm de diâmetro permitiram que os níveis de espalhamento se aproximassem do tecido mole humano. O phantom simula uma mama em posição de supino, apresentando um diâmetro de 12 cm e uma altura de 6 cm. No seu interior foram inseridas estruturas sólidas e viscosas, tais como cera de carnaúba e mel de abelha, Apis mellifera, e também a própria parafina gel, com 10% de micro esferas de vidro, representando \"tumores\" e \"massas císticas\", as quais são de cores diferentes para facilitar a identificação após serem aspiradas. / The main aim of work was the construction and characterization of acoustics proprieties of a prototype of phantom for the training of the breast biopsy guided by ultrasound. An important property of this phantom is its capacity of being thermically rebuilt after punctuated during the training and/or suffered any mechanic damage. For this purpose, a recycling system was developed especially for the phantom. Among the materials available for this study, the paraffin gel was shown to be stable for the proposed experimental conditions, such as room temperature between 22 and 26oC, a density of 0.85 g/cm3 for the sample with a concentration of 4%, which is inferior to the density of the soft tissue (~ 1g/cm3), therefore becoming the materials used in the following experiments. The material which simulates the tissue was obtained by the addition of solid particles of glass to the paraffin gel. Two acoustic measurement techniques were used to characterization of the material. For the first technique amplitude mode (mode-A) was applied and for the second brightness mode (mode-B) was applied. In a frequency range of diagnostic ultrasounds (between 1 and 10 MHz), the attenuation coefficient for mode-A was of 0.75 dB/cm/MHz, equivalent to the one indicated by the soft tissue literature. The sound speed was of 1431.2 m/s at a temperature of 22oC. This velocity is lower than the average velocity for the breast tissue, which is of 1510 m/s, there being closer to the velocity for fat, i.e., 1470 m/s. The attenuation of the brightness mode was studied through the comparison of various relative attenuations of the images given by the samples, being inversely correlated to the attenuation found in the amplitude mode. The speed of the sound was also evaluated by that technique being obtained a medium value of 1416.1 m/s for the studied samples. Solid particles of glass of 45-75 µm of diameter allowed the level of scattering to be close to the one the human soft tissue. The phantom simulates a breast in the supine position, with a 12 cm diameter and 6 cm height. Solid and viscose structures were inserted in its interior as honey of Apis mellifera and the carnauba wax, and also the own paraffin gel, with 10% micro glass spheres, representing \"cystic masses\" and \"tumors\", each with a different coloration to facilitate the identification after their removal.

Page generated in 0.0829 seconds