• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Complexo miointimal das carótidas comum e interna de portadores de esquistossomose mansônica hepatoesplênica: avaliação com eco- Doppler colorido

Valença Guimarães, André January 2006 (has links)
Made available in DSpace on 2014-06-12T16:29:12Z (GMT). No. of bitstreams: 2 arquivo5723_1.pdf: 2050447 bytes, checksum: f4653c7869a9fd0f400956f436231c78 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / O objetivo do estudo foi avaliar a espessura do complexo miointimal (IMT) das carótidas comum e interna, num grupo de portadores de esquistossomose hepatoesplênica (EHE) não tratados cirurgicamente (EHE-NO), noutro grupo já submetido a cirurgia para descompressão do sistema porta por esplenectomia e ligadura da veia gástrica esquerda e comparar com um grupo de volutários de condições sócio-econômico-ambientais similares, não portadores de esquistossomose (controle). Utilizando um aparelho de ultra-som Doppler de 7,5MHz foram mensurados os IMT de três grupos de voluntários, de ambos os gêneros, com idades que variaram de 20 a 60 anos, sendo avaliados os IMT máximos, IMT médios, IMT mínimos e seus desvios-padrão, das carótidas comuns e internas e feitas as comparações entre os grupos e suas associações com fatores de risco: idade, hipertensão arterial e tabagismo. Os resultados mostraram que não houve diferença significante na média dos IMT, entre os lados direito e esquerdo e nem entre os grupos. Nos pacientes tratados cirurgicamente, assim como nos indivíduoscontrole confirmou-se a associação, já conhecida, com os fatores de risco para aterosclerose (idade, hipertensão arterial e tabagismo). Contudo, não se observou este comportamento nos pacientes não operados, permitindo sugerir que a EHE sem tratamento cirúrgico possa conferir alguma proteção contra a aterogênese em seres humanos
72

Desempenho da ultra-sonografia na avaliação dos linfonodos axilares em mulheres com cancer de mama

Jales, Rodrigo Menezes, 1975- 30 August 2005 (has links)
Orientador: Emilio Francisco Marussi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-05T02:39:10Z (GMT). No. of bitstreams: 1 Jales_RodrigoMenezes_M.pdf: 1089775 bytes, checksum: f88eb720b9e6032407ba3a3d6c84e5df (MD5) Previous issue date: 2005 / Resumo: Introdução: a avaliação clínica tem baixo desempenho na previsão do envolvimento linfonodal em mulheres com câncer da mama. Assim, a dissecção axilar é necessária para o estadiamento patológico. A ultra-sonografia tem sensibilidade superior à mamografia e ao exame físico na avaliação linfonodal axilar. Objetivos: Avaliar o desempenho de diversas características ultra-sonográficas morfológicas (12) e Doppler (7) na detecção de metástases linfonodais em mulheres com câncer de mama. Métodos: Foram incluídas 181 axilas, de 179 mulheres, entre janeiro e dezembro de 2004. Os exames ultra-sonográficos foram realizados com transdutor linear em tempo real (TOSHIBA- Power Vision-6000 - modelo SSA-370A). Para o estudo de parâmetros morfológicos foram utilizadas freqüências entre 7,5 e 12 megahertz (Mhz). Para os parâmetros Doppler foi utilizada a freqüência de 5Mhz. Subseqüentemente, as pacientes foram submetidas à axilectomia dos níveis I, II e III (158) ou à técnica do linfonodo sentinela (23). Para a análise dos dados utilizaram-se estatística descritiva e árvore de decisão. Resultados: Ao exame ultra-sonográfico foi identificado pelo menos um linfonodo axilar em 173 (96%) exames. O exame histológico detectou metástase linfonodal em 87 mulheres (48%). As melhores sensibilidades dos critérios morfológicos foram encontradas com o volume do linfonodo (62%), diâmetro antero-posterior (62%) e local do centro ecogênico (56%). Embora a especificidade da invasão da gordura adjacente (100%), regularidade das margens (92%) e da ecotextura do parênquima (99%) tenham sido elevadas, a sensibilidade destes parâmetros foi muito baixa. Nenhum critério do Doppler alcançou 50% de sensibilidade. A árvore de decisão selecionou a localização do centro ecogênico, ecotextura do parênquima e regularidade das margens como melhor associação de parâmetros. Conclusão: O desempenho da ultra-sonografia na detecção de metástases nos linfonodos axilares foi desapontador na detecção de metástases linfonodais axilares em mulheres com câncer de mama / Abstract: Introduction: The clinical evaluation is not accurate to predict the lymph node involvement in woman with breast cancer. Therefore, the axillary dissection is necessary to the pathological stagement. The ultrasonography is more sensitive than palpation and mammography in the detection of metastatic lymph nodes. Objective: To evaluate the role of ultrasonographic features, morphologic (12) and Doppler (7), in the detection of lymph node metastases in breast cancer patients. Methods: 181 axillas from 179 women were included. The ultrasonographic examinations were performed with real-time linear probe (TOSHIBA- Power Vision-6000 - model SSA-370A). Morphologic parameters were studied with a frequency of 7.5-12 Mega-hertz (Mhz). To Doppler parameters, a frequency of 5Mhz was used. Subsequently, the women were submitted to axillary dissection of levels I, II and III (158) or to the sentinel lymph node technique (23). Descriptive statistics and tecision tree were used to analyze the data. Results: At least one lymph node was detected in 173 (96%) by ultasonographic exams. Histologic examination detected lymph node metastases in 87 women (48%). The best sensitivity among the morphologic features were found with the volume (62%), the antero-posterior diameter (62%) and fatty hilum placement (56%). Beside the specificity of the extra capsular invasion (100%), border regularity (92%) and cortex echogenicity (99%) were high, the sensitivity of these features were to low. None of the Doppler features reached 50% of sensitivity. The decision tree test selected the ultrasonographic features: fatty hilum placement, border regularity and cortex echogenicity as the best parameters association. Conclusion: The role of axillary ultrasonography in the detection of axillary lymph node metastases in woman with breast cancer was disappointing / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
73

Avaliação ultra-sonografica do diagnostico e tratamento da displasia do desenvolvimento do quadril

Pacheco, Elisa Maria de Brito, 1961- 23 June 1997 (has links)
Orientador: Rubens Marcondes Pereira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-22T07:58:12Z (GMT). No. of bitstreams: 1 Pacheco_ElisaMariadeBrito_D.pdf: 6480056 bytes, checksum: 9be71280f4ad8869ad3383c28ae1564e (MD5) Previous issue date: 1997 / Resumo: No período de abril de 1990 a julho de 1993 foi realizado um estudo prospectivo de 225 lactentes com suspeita clínica de displasia do desenvolvimento do quadril (DDQ). OS correspondentes 450 quadris foram avaliados por exames clínicos, radiológicos e ultra-sonográficos. O objetivo deste trabalho foi avaliar os métodos de Graf, Harcke e Morin quanto à sua sensibilidade, especificidade e acurácia no diagnóstico de DDQ, definir a confiabilidade dos critérios ultra-sonográficos para indicação do tratamento, assim como a eficácia destes métodos no seguimento das crianças em tratamento. O diagnóstico referente à articulação coxo-femoral usado como teste padrão fundamentou-se em critérios clínicos, radiológicos e evolutivos, sendo os quadris divididos em 3 grupos: normal, displásico e/ou subluxado e luxado. Os grupos com quadris normais e os displásicos e/ou subluxados foram subdivididos em diagnósticos de certeza, de segurança e de probabilidade. Foram analisados os valores de sensibilidade, especificidade, proporção de falsos positivos e acurácia para os diversos pontos de corte no exame ultra-sonográfico pelos métodos de Graf, Harcke e Morin, separadamente. Comparando-se os resultados, constatou-se que o melhor método ultra~sonográfico para o diagnóstico de DDQ foi o de Graf, sendo o critério de maior confiabilidade para indicação do tratamento o ângulo alfa (ângulo do teto acetabular ósseo). Considerando-se o ponto de corte no nível IIa( +), o método de Graf obteve uma sensibilidade de 100% e uma especificidade de 96,6% par" os diagnósticos de certeza, 87,5% e 96,4% para os diagnósticos de certeza e de segurança e 87,5% e 93,8% para os de certeza, de segurança e de probabilidade. Através do método de Graf não foi possível estabelecer um critério definido para diferenciar a imaturidade fisiológi,cà do quadril e o quadril displásico incipiente, que necessita de tratamento. No método de Harcke o melhor ponto de corte foi obtido ao se classificar os quadris cuja única alteração era a instabilidade como normais. O valor de sensibilidade foi de 100% e o de especificidade 95,8% para os diagnósticos de certeza, 80% e 96,4% para os diagnósticos de certeza e de segurança e 80% e 96,6% para os de certeza, de segurança e de probabilidade. No método de Morin, considerando-se como normais os quadris com a porcentagem de cobertura da cabeça femoral pelo teto acetabular ósseo maior ou igual a 44%, o valor de sensibilidade foi de 93,3% e o de especificidade 76,2% para os diagnósticos de certeza, 79,2% e 77,9% para os diagnósticos de certeza e de segurança, e 79,2% e 74,8% para os de certeza, de segurança e de probabilidade. Quanto ao controle ultra-sonográfico do quadril da criança tratada com alças de Pavlik, o método de Harcke é eficaz para a comprovação da sua redução, e o método de Graf para a avaliação da melhora morfológica do mesmo. Nas crianças com gesso pélvico-podálico, a ultra-sonografia não foi eficaz na avaliação da redução do quadril pela dificuldade de se identificar pontos anatõmicos que permitissem estabelecer a posição da cabeça femoral e do acetábulo, sendo preferível a tomografia computadorizada / Abstract: This prospective study was performed from April 1990 to July 1993. Two hundred and twenty five infants clinically suspected of developmental dysplasia of the hip (DDH) were examined, comprising 450 single hip studies. All hips were subjected to clinical, radiographic and ultrasonographic exams. The purpose was to determine the sensitivity, specificity, and accuracity of Oraf's, Harcke's and Morin's techniques in the diagnosis of DDH, to define the reliability of the ultrasound cri teria for treatment indication, and the efficacy of these techniques in the evaluation of the infants during treatment. The gold standard was based on clínical and radiographic examinations. The hips were classified in 3 groups: normal, dysplasic andJor subluxation and dislocated. The hips classified as normal and dysplasic andJor subluxation were further divided in definite, safety and probability diagnosis. The sensitivity, specificity, false-positive ratio and accuracity were analysed for the various cutting points in the ultrasonographic exam, according to the Oraf's, Harcke's and Morin's techniques, separatedly. Comparing the results, it was proven that the most adequate ultrasonographic technique for the diagnosis of DDH is the Oraf' s technique, being the alpha angle (acetabular inclination angle), the most reliable criteria for treatment indication. Considering the cutting point in the leveI of type IIa( +), the Oraf's technique reached 100% of sensitivity and 96,6% of specificity for the definite diagnosis; 87,5% and 96,4% for the definite and safety diagnosis I~nd finally 87,5% and 93,8% for the definite, safety and probability diagnosis. Through Oraf' s technique, it was not possible to establish a definite criteria in order to distinguish the phisiologic. immaturity of the hip and minor dysplasia of acetabular development, which Ileé'ds treatment. Using Harcke's technique, the Best cutting point was achieved when classifying the hips with isolated instability as normal. The sensitivity value was 100% and the specificity value was 95,8% for the definite diagnosis; 80,0% and 96,4% for the definite and safety diagnosis and finally 80,0% and 96,6% for the definite, safety and probability diagnosis. Using Morin's technique, considering as normal the hips with the percentage of coverage of the femoral head by the bony acetabulum greater or equal to 44%, the sensitivity value was 93,3% and the specificity value was 76,2% for the definite diagnosis; 79,2% and 77,9% for the definite and safety diagnosis and finally 79,2% and 74,8% for the definite, safety and probability diagnosis. Regarding the ultrasonographic control of the infant' s hip treated with the Pavlik harness, Harcke's technique is efficient for ensuring its reduction, and Graf' s technique for evaluating its morphologic improvement. In the infants placed in spina casts, ultrasonography was not efficient m evaluating the hip's reduction due to difficulties in the identification of anatomic landmarks of the femoral head and the acetabulum, so the preference should be for computed tomography / Doutorado / Doutor em Medicina
74

Modelos de implosão de bolhas esféricas para sonoluminescência

Xavier, Christine Fernandes 21 December 2000 (has links)
Orientador: Roberto Antonio Clemente / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin" / Made available in DSpace on 2018-07-27T10:17:15Z (GMT). No. of bitstreams: 1 Xavier_ChristineFernandes_D.pdf: 1987811 bytes, checksum: c93687e4e77aad2b24119978aedca0f2 (MD5) Previous issue date: 2000 / Resumo: Os processos de relaxação associados aos graus de liberdade vibracional, de dissociação e ionização em bolhas de gás diatômicos e monoatômicos em SBSL (sonoluminescência de uma única bolha) são analisados através da elaboração de modelos hidrodinâmicos apropriados onde o efeito da condução térmica na interface bolha-líquido é incluído de maneira auto-consistente. Simulações numéricas dos diversos processos de relaxação permitiram caracterizar a dinâmica de tais bolhas, além de permitir a obtenção dos valores associados às frações dissociadas e ionizadas dos gases no interior da cavidade. Em conexão com a análise do processo de ionização, um modelo para a emissão de radiação em SBSL é construído, suas conseqüências sendo analisadas e discutidas. O efeito da condução térmica na interface bolha líquido é também considerado / Abstract: We analyze, under appropriate hydrodynamical models, the processes of relaxation associated to vibrational degrees of freedom, dissociation and ionization of diatomic and monoatomic gas bubbles in the sonoluminescence phenomena. Numerical simulations allowed to characterize the dynamics of such bubbles and to infer values for dissociated and ionized fractions of gases that are present inside the cavity. In connection to an analysis of ionization process, we have constructed a model for the emission of SBSL (single bubble sonoluminescence) radiation whose main features are discussed. The effect of thermal conduction at the bubble-liquid interface is also considered. / Doutorado / Física / Doutor em Ciências
75

Interface gestual ultrassonica

Mendes, Gilberto 28 July 2018 (has links)
Orientador : Furio Damiani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T01:35:01Z (GMT). No. of bitstreams: 1 Mendes_Gilberto_M.pdf: 1308250 bytes, checksum: 688e2fb1966c3eb16ba52233feb5805b (MD5) Previous issue date: 1999 / Mestrado
76

Sistema ultra-sonico para medida volumetrica

Silva, Isaias Ferreira da 28 July 2018 (has links)
Orientador: Carlos Alberto dos Reis Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T14:25:31Z (GMT). No. of bitstreams: 1 Silva_IsaiasFerreirada_M.pdf: 4466930 bytes, checksum: ad46dce85a289d4ec4bb0692137830e9 (MD5) Previous issue date: 1999 / Resumo: Um método inovador para a medida do volume de um líquido dentro de um recipiente fechado é proposto. A motivação deste trabalho é a aplicação do método para a medida do volume de combustível dentro de um tanque de automóvel. Este método se baseia no fenômeno de reverberação sonora que relaciona o tempo de decaimento da intensidade do som dentro de um ambiente com o seu volume. Este tempo, conhecido como tempo de reverberação, está associado ao volume vazio dentro do recipiente, ao material com o qual é feito e ao tipo de líquido que este recipiente contém. Sendo conhecido o volume total do recipiente, determina-se o volume de líquido presente. Para determinar a relação existente entre o tempo de reverberação e o volume de líquido é necessário conhecer as características acústicas do sistema; para isto foram realizados experimentos em um recipiente metálico de dimensões semelhantes as de um tanque automotivo, utilizando-se água como líquido cujo volume deve ser medido. Como fonte sonora utiliza-se um transdutor de ultra-som ao qual se aplicam pulsos de excitação periódica. O resultado destes experimentos têm confirmado a validade do método proposto / Abstract: An innovative method to measure the liquid volume inside an enc1osure container is proposed. The motivation for this research work has been the development of a system to measure the fuel volume in an automotive fuel tank. This method is based on the reverberation phenomenon, which relates the sound power time decay in a vessel with its volume. By measuring this time, which is known as reverberation time, the empty volume inside the enc1osurecan be determined. Once the total volume is known the liquid volume is found. The reverberation time is dependent on the empty volume inside the enclosure, the material properties of the vessel and the liquid inside the enclosure. The acoustical characteristics of the system are determined by several experiments with a metallic enclosure, whose dimensions are approximately the same as those an automotive fuel tank. The sound source is an ultrasonic transducer excited by periodic bursts. Experimental results have confirmed the validity of the proposed method / Mestrado / Eletronica e Comunicações / Mestre em Engenharia Elétrica
77

Sistema ultra-sonico para auxilio ao diagnostico da osteoporose

Maia, Joaquim Miguel 29 July 2018 (has links)
Orientador : Eduardo Tavares Costa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T01:42:21Z (GMT). No. of bitstreams: 1 Maia_JoaquimMiguel_D.pdf: 5619008 bytes, checksum: 5ebc4069e04b7e41fbe6ff2f845e826e (MD5) Previous issue date: 2001 / Doutorado
78

Validação da curva dos valores normais do indice de liquido amniotico por idade gestacional para a predição de situações perinatais adversas

Machado, Maria Regina Marrocos 29 July 2018 (has links)
Orientador : Jose Guilherme Cecatti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-29T01:35:24Z (GMT). No. of bitstreams: 1 Machado_MariaReginaMarrocos_D.pdf: 2277265 bytes, checksum: 9785844a20fc3cb549e5559193e942bc (MD5) Previous issue date: 2001 / Doutorado
79

Classificação de peças estruturais de madeira atraves do ultra-som

Bartholomeu, Andre 31 July 2018 (has links)
Orientador: Raquel Gonçalves / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-31T15:04:01Z (GMT). No. of bitstreams: 1 Bartholomeu_Andre_D.pdf: 4677253 bytes, checksum: aeb6c4fb1290cb31a9118f38c8000130 (MD5) Previous issue date: 2001 / Resumo: No Brasil, país que detém uma das maiores reservas florestais do planeta, a madeira é um material de construção cuja utilização ainda requer muita tecnologia, tanto no que se refere aos procedimentos de processamento quanto na aplicação. Um dos problemas enfrentados pela indústria madeireira é que o material madeira não é submetido à classificação e, portanto, não há certificação de qualidade nem tampouco de segurança quanto às suas propriedades mecânicas. Sendo assim, não se conhece, de maneira segura, as características da madeira e, portanto, seu emprego fica à mercê do empirismo. A Norma brasileira "Projeto de Estruturas de Madeira" - NBR 7190/97 prevê a caracterização de lotes de madeira através do ensaio de compressão paralela às fibras em corpos-de-prova de dimensões 0,05 x 0,05 x 0,15 m e classifica as peças segundo classes de resistência. Entretanto, a execução de tais ensaios nem sempre é possível, para o consumidor final ou para a indústria madeireira de transformação, perpetuando o problema do desconhecimento efetivo das características mecânicas da madeira produzida elou adquirida. O objetivo deste trabalho foi avaliar a existência de correlação entre resultados obtidos utilizando um método de ensaio não-destrutivo (END) - ultra-som - com aqueles obtidos por métodos tradicionais de obtenção de valores de resistência e rigidez em peças de madeira de dimensões nonnatizadas e de dimensões estruturais (ensaios estáticos destrutivos). Após ser verificada a correlação, em uma segunda etapa buscou-se propor um método de classificação de peças estruturais de madeira, através da velocidade de propagação de ondas longitudinais. Para atingir os objetivos citados, foram realizados ensaios estáticos de compressão paralela às fibras em corpos-de-prova normatizados pela NBR 7190/97; ensaios à flexão estática em vigas de dimensões estruturais de dimensões 0,06 x 0,12 x 2,00 m, normatizados pela ASTM, e, também, ensaios utilizando equipamento de ultra-som. Os ensaios utilizando equipamento de ultra-som foram sempre realizados nas mesmas peças submetidas ao ensaio destrutivo, para que se pudesse correlacionar os resultados de maneira mais precisa, uma vez que a madeira, até mesmo dentro da mesma árvore, apresenta grande variabilidade de características. Três espécies foram utilizadas no trabalho: duas dicotiledôneas, Cupiúba (Goupia glabra) e Eucalipto Citriodora (Eucalyptus citriodora) e uma conífera, Pinus elliottii (Pinus elliottii). Tanto os corpos-de-prova de dimensões normatizadas, quanto as vigas de dimensões estruturais, foram ensaiadas em dois teores de umidade: saturadas e secas ao ar (aproximadamente 12%). Os resultados obtidos demonstraram, estatisticamente, que o ultra-som pode ser utilizado como ferramenta para avaliar as propriedades mecânicas da madeira das três espécies estudadas, nos dois teores de umidade, bem como nos dois tipos de peça (vigas e corpos-de-prova) avaliados. Particularmente para as vigas de dimensões estruturais, as correlações entre a velocidade de propagação das ondas na direção longitudinal e o módulo de elasticidade à flexão estática foram altamente significativas, o que permitiu a proposição de faixas de velocidade associadas à classificação de peças estruturais que, na prática, permite que se associe a velocidade de propagação em peças recém-desdobradas e com alto teor de umidade, às propriedades mecânicas na condição seca ao ar. Dessa maneira, ficou evidenciado que o ensaio por ultra-som, por ser de fácil execução, de baixo custo e não-destrutivo, constitui -se numa tecnologia que pode ser transferida à indústria madeireira podendo ser, portanto, um instrumento imprescindível para o futuro da utilização da madeira no Brasil / Abstract: In Brazil, a country that retains one of the biggest forest reserves in the planet, wood is a building material whose utilization still requires a lot of technology, considering the processing procedures or application. One important problem that wood industry faces is that this material has not grading and there is neither quality certification nor safety on mechanical properties of the pieces. Thus, its characteristics are not surely known and their use are based on empiricism. The Brazilian Standard for Wood Structures Design NBR 7190/97 foresees the characterization of wood lots through compression tests parallel to grain in specimens with dimensions 0,05 x 0,05 x 0,15 m and the grading method of pieces by strength classes. However to realize these tests is not an easy task to the final costumer or to the wood industry, perpetuating the ignorance problem of the actual mechanical characterists of the producedlacquired wood. The purpose of this research was to evaluate the existence of correlation between the results of a nondestructive test (ultrasound) and the results of traditional static methods used to obtain strength and rigidity values in normalized size and structural size pieces of wood. Afier that, this research proposed a grading method for structural size pieces of wood through the longitudinal ultrasound wave velocity. To reach the proposals, static tests of compression parallel to grain in specimens normalized by NBR 7190/97 were realized; bending tests in structural size beams according to ASTM and, ultrasound tests as well. To correlate the results with more accuracy, the ultrasound tests were rea1izedin the same pieces used in the destructive tests because wood presents large variability of characteristics inside the same piece. Three species were studied in this research : two hardwoods - Cupiúba (Goupia glabra) and Eucalyptus Citriodora (Eucalyptus citriodora) and one softwood - Pinus elliottii (Pinus elliottii). AlI the pieces, in normalized size and structural size, were tested in two moisture contents: satured and air-dried. The results show, statiscal1y, that ultrasound can be used as a good tool to evaluate the mechanical properties of wood in two sizes (beams and specimens) and the two moisture contents utilized. Specially for structural size beams, the correlations were highly significant between the longitudinal ultrasound wave velocity and the bending static Young' s modulus and they waited for the opportunity to create velocity bands associated to structural size beams grading. For practical purposes, these bands permit the association of wave velocities in newly-sawed beams of satured wood with air-dried meehanical properties in these pieees. Thus, it is evident that, through a simple, 10weost and nondestruetive test, this teehnology ean be transfelTedto wood industry and beeome an indispensable tool to the future of wood use in Brazil / Doutorado / Construções Rurais / Doutor em Engenharia Agrícola
80

Avaliação da profundidade de penetração de ondas longitudinais criticamente refratadas / Avaliation of the penetration depth of critically refracted longitudinal waves

Fraga, Ricardo dos Santos 26 February 2007 (has links)
Orientador: Auteliano Antunes dos Santos Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-11T09:56:38Z (GMT). No. of bitstreams: 1 Fraga_RicardodosSantos_M.pdf: 5203547 bytes, checksum: b694c735f82895b84c9dd31aa8738fc7 (MD5) Previous issue date: 2007 / Resumo: Na medição de tensões residuais com ultra-som, é necessário conhecer a profundidade de propagação da onda. Sem isso, é impossível definir onde a tensão está sendo medida. Neste trabalho, procurou-se uma relação entre características físicas de transdutores piezoelétricos (freqüência de vibração) e a profundidade de penetração de ondas longitudinais criticamente refratadas (ondas Lcr). Primeiramente buscou-se uma base teórica que sinalizasse alguma relação entre a freqüência destas ondas e a profundidade na qual as mesmas se propagam. Depois de definida a teoria, foi estabelecida um procedimento experimental para comprovação prática. Para isto, foi utilizado um tipo de material metálico (aço API 5L X70) no qual ondas longitudinais criticamente refratadas foram excitadas com três diferentes níveis de freqüência (2,25; 3,5 e 5 MHz). Depois das medições realizadas no material, rasgos com diferentes profundidades foram usinados nas amostras metálicas e novamente ondas Lcr foram excitadas nos três níveis de freqüência definidos anteriormente. Os resultados foram comparados e uma relação entre profundidade de penetração e freqüência do transdutor pôde ser obtida. Para qualquer das freqüências, a profundidade de propagação esteve entre 1 e 2 comprimentos de onda / Abstract: This investigation describes a model which permits evaluating the local properties during the process of wax formation. To achieve this objective it was necessary to know the local heat and mass transfer coefficient and hence solve the flow, heat and humidity fields. The solution is based upon converting the fields function in terms of the vorticity and stream function. Once the local heat and mass transfer coefficients are determined a two stage model for the wax formation was used to determine the growth rate of the wax layer. The results were then compared with existing numerical and experimental results and good agreement were found. Additional results were obtained to demonstrate the variation of wax density, temperature field and wax thickness. These results were analyzed and commented. The results obtained from this investigation are important in future studies in wax formation as well as in the energy optimization of the dewaxing process / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica

Page generated in 0.0798 seconds