• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 26
  • 12
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 174
  • 174
  • 63
  • 31
  • 23
  • 20
  • 18
  • 18
  • 16
  • 14
  • 14
  • 14
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Comparing chest X-rays with ultrasound for the prediction of left atrial size at Pretoria Academic hospital

Quinton, Susanna Jacoba January 2007 (has links)
Thesis (MSc. (Faculty of Health Sciences))--University of Pretoria, 2007. / Summary in English and Afrikaans. Includes bibliographical references.
132

Ultrasound and photoacoustic imaging to guide and monitor photothermal therapy

Shah, Jignesh Mukesh, January 1900 (has links)
Thesis (Ph. D.)--University of Texas at Austin, 2008. / Vita. Includes bibliographical references.
133

Pré-eclâmpsia e risco de alterações no ultrassom de crânio de recém-nascidos prematuros /

Giacóia, Glauce Regina Fernandes. January 2015 (has links)
Orientador: Ligia Maria Suppo de Souza Rugolo / Coorientador: Saskia Maria Wiegerinck Fekete / Banca: Celeste Gomez Sardinha Oshiro / Banca: João Cesar Lyra / Resumo: Introdução: Pré-eclampsia (PE) é a complicação médica mais frequente da gestação e os dados são conflitantes quanto ao prognóstico dos filhos de mães com PE. Objetivo: Determinar a prevalência de alterações ao ultrassom de crânio (USc) e os fatores de risco associados, em prematuros de muito baixo peso (PT-MBP) de mães com PE em comparação aos de normotensas. Investigar a influência da restrição do crescimento intrauterino nos achados ultrassonográficos. Métodos: Coorte de PT-MBP nascidos no serviço e internados na UTI neonatal do HC da Faculdade de Medicina de Botucatu-UNESP, de janeiro de 2009 a dezembro de 2013. Excluídos os que não realizaram USc. Foram constituídos 2 grupos de PT-MBP: 1- mães PE e 2- Mães normotensas, que foram comparados quanto às características, gestacionais e neonatais. Desfecho: alterações no USc (hemorragia periintraventricular graus I a IV, e leucomalácia periventricular). Por regressão logística foram avaliados os fatores de risco ou proteção para as alterações no USc. Resultados: Foram estudados 381 PTMBP, sendo 151 de mães pré-eclampticas e 230 de mães normotensas. A prevalência de alterações no USc foi de 39%, sendo menor no grupo PE (30% versus 45%; p=0,007). No grupo PE a idade gestacional foi maior, a restrição do crescimento intrauterino foi muito frequente, e a morbidade neonatal menor. Na regressão logística a PE não foi identificada como fator de risco ou proteção para alterações ultrassonográficas. Também o uso de sulfato de magnésio, a corioamnionite e a restrição do crescimento intrauterino não se associaram com os achados ultrassonográficos. A idade gestacional e o parto cesáreo foram fatores de proteção, e a administração de surfactante, uso de inotrópicos e infecção foram fatores de risco. Conclusão: A prevalência de alterações ao USc foi elevada nos PT-MBP e embora menos frequente no grupo PE, esta doença, bem como a... / Abstract: Background: Preeclampsia (PE) is the most common medical complication in pregnancy, however data on the morbidity and outcome for preterm infants of preeclamptic mothers are conflicting, and few studies address this issue. Objective: To determine the prevalence of cranial ultrasound abnormalities and to identify variables that affect the risk of these abnormalities in very low birthweight infants (VLBW) from preeclamptic and normotensive mothers. To investigate the influence of intrauterine growth restriction on the cerebral ultrasound findings. Methods: A cohort of all inborn VLBW infants admitted to NICU at University Hospital-Botucatu School of Medicine-UNESP from January 2009 to December 2013. Infants who was not assessed by cranial ultrasound screening were excluded. Two groups of infants: 1: Preeclamptic mothers (PE) and 2: Normotensive mothers were compared regarding gestational and neonatal data. Primary outcome: cranial ultrasound abnormalities (intraventricular hemorrhage grades I to IV and periventricular leukomalacia). Logist regression analyses were used to identify risk factors for ultrasound abnormalities. Results: A total of 381 VLBW infants were studied, 151 born to preeclamptic mothers and 230 from normotensives. The prevalence of abnormal ultrasound findings was 39%, with lower rate in PE group (30% vs 45%; p=0,007). In PE group the gestational age was higher, intrauterine growth restriction was very common and neonatal morbidity was lower. PE was not an independent risk or protective factor for cranial ultrasound abnormalities on logistic regression analysis. Antenatal magnesium sulphate therapy, chorioamnionitis and intrauterine growth restriction were not associated with ultrasound findings. Gestational age and cesarean delivery were protective factors, whereas surfactant administration, inotropic use within the first 72 hours of life, and neonatal infection were associated with increased risk of cranial ultrasound ... / Mestre
134

Ultrassonografia para bloqueios periféricos em crianças : revisão sistemática e metanálise de ensaios clínicos randonizados /

Cabral, Lucas Wynne. January 2015 (has links)
Orientador: Norma Sueli Pinheiro Modolo / Coorientador: Regina Paolucci El Dib / Banca: Eliana Marisa Ganem / Banca: Lais Helena Navarro e Lima / Banca: Eneida Maria Vieira / Banca: José Fernando Amaral Meletti / Resumo: Introdução: acredita-se que a anestesia regional guiada por ultrassonografia (USG) pode melhorar a eficácia dos bloqueios de nervos periféricos e reduzir as complicações na população pediátrica, porém essa hipótese ainda não foi previamente testada de forma quantitativa. Objetivo: a proposta desta revisão sistemática de ensaios clínicos randomizados (ECR) foi avaliar se o uso da ultrassonografia em pediatria melhoraria a taxa de sucesso dos bloqueios e reduziria o índice de complicações comparativamente a outros métodos tradicionais de localização de nervos. Métodos: a pesquisa sistemática, extração dos dados, avaliação crítica e análise conjunta dos dados seguiram as recomendações para a realização de revisões sistemáticas propostas pela Colaboração Cochrane e pela declaração PRISMA. A estratégia de busca incluiu as bases CENTRAL, EMBASE, Medline e Lilacs. A última pesquisa foi realizada em novembro de 2014. O risco relativo (RR) e a diferença média (DM), com seus respectivos intervalos de confiança de 95% (IC 95%), foram calculados utilizando-se o programa estatístico Revman para dados dicotômicos e contínuos, respectivamente. Resultados: onze ensaios clínicos randomizados, publicados entre 2004 e 2013, perfazendo um total de 634 pacientes, cumpriram os critérios de inclusão. A qualidade metodológica foi considerada moderada. Houve um pequeno benefício da ultrassonografia na taxa de sucesso (RR 1,19; IC 95% 1,07-1,32) que foi variável de acordo com a região anatômica avaliada, associado a uma redução na necessidade de analgesia no pós-operatório com o uso da ultrassonografia (RR 0,2; IC 95% 0,11-0,34). Apenas uma complicação foi reportada nos estudos incluídos. Uma punção vascular em um paciente do grupo controle durante realização do bloqueio ílio-inguinal/ílio-hipogástrico (II/IH). Conclusão: existe moderada evidência de que a ultrassonografia quando utilizada para... / Abstract: Background: it has been suggested that ultrasound-guided regional anesthesia could improve the blockade efficacy and decrease complication rates in the pediatric population, but this hypothesis has not previously been adequately tested in a quantitative manner. Aim: the purpose of this systematic review of randomized clinical trials (RCT) is to assess whether the use of ultrasonography in the pediatric population has advantages over any other method of nerve location, such as the anatomical landmark-based technique, paraesthesia or use of an electrical nerve stimulator. Methods: the systematic search, data extraction, critical appraisal and pooled analysis were performed according to the Cochrane Handbook and PRISMA guidelines. The search strategy included the CENTRAL of the Cochrane Library, Medline, EMBASE, and Lilacs. The date of the last search was November 5, 2014. The relative risk (RR), mean difference (MD) and their corresponding 95% confidence intervals (95% CIs) were calculated using the Revman statistical software for dichotomous and continuous outcomes, respectively. Results: eleven randomized, clinical, controlled trials (published between 2004 and 2013) with a total 634 patients met the inclusion criteria. The methodological quality of the included studies was considered regular. There was a slight benefit of ultrasound to the success rate (RR 1.19, 95% CI 1.07 to 1.33), which was variable according to the anatomical region studied and a more important reduction of the analgesia requirement in the postoperative period with the use of ultrasound for peripheral nerve blocks (RR 0.2, 95% CI 0.11-0.34). There was only one complication reported (blood vessel puncture in one control group). Conclusions: there is moderate evidence that the use of ultrasound-guided peripheral nerve block in children reduces the number of patients requiring additional analgesia in the postoperative period and ... / Doutor
135

Pré-eclâmpsia e risco de alterações no ultrassom de crânio de recém-nascidos prematuros / Pre-eclampsia and risk of cerebral ultrasound abnormalities in preterm infants

Giacóia, Glauce Regina Fernandes [UNESP] 26 February 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:23:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-26. Added 1 bitstream(s) on 2015-12-10T14:29:43Z : No. of bitstreams: 1 000848644.pdf: 897471 bytes, checksum: c19f5ecc788d0375e93aee6bd4e968f6 (MD5) / Introdução: Pré-eclampsia (PE) é a complicação médica mais frequente da gestação e os dados são conflitantes quanto ao prognóstico dos filhos de mães com PE. Objetivo: Determinar a prevalência de alterações ao ultrassom de crânio (USc) e os fatores de risco associados, em prematuros de muito baixo peso (PT-MBP) de mães com PE em comparação aos de normotensas. Investigar a influência da restrição do crescimento intrauterino nos achados ultrassonográficos. Métodos: Coorte de PT-MBP nascidos no serviço e internados na UTI neonatal do HC da Faculdade de Medicina de Botucatu-UNESP, de janeiro de 2009 a dezembro de 2013. Excluídos os que não realizaram USc. Foram constituídos 2 grupos de PT-MBP: 1- mães PE e 2- Mães normotensas, que foram comparados quanto às características, gestacionais e neonatais. Desfecho: alterações no USc (hemorragia periintraventricular graus I a IV, e leucomalácia periventricular). Por regressão logística foram avaliados os fatores de risco ou proteção para as alterações no USc. Resultados: Foram estudados 381 PTMBP, sendo 151 de mães pré-eclampticas e 230 de mães normotensas. A prevalência de alterações no USc foi de 39%, sendo menor no grupo PE (30% versus 45%; p=0,007). No grupo PE a idade gestacional foi maior, a restrição do crescimento intrauterino foi muito frequente, e a morbidade neonatal menor. Na regressão logística a PE não foi identificada como fator de risco ou proteção para alterações ultrassonográficas. Também o uso de sulfato de magnésio, a corioamnionite e a restrição do crescimento intrauterino não se associaram com os achados ultrassonográficos. A idade gestacional e o parto cesáreo foram fatores de proteção, e a administração de surfactante, uso de inotrópicos e infecção foram fatores de risco. Conclusão: A prevalência de alterações ao USc foi elevada nos PT-MBP e embora menos frequente no grupo PE, esta doença, bem como a... / Background: Preeclampsia (PE) is the most common medical complication in pregnancy, however data on the morbidity and outcome for preterm infants of preeclamptic mothers are conflicting, and few studies address this issue. Objective: To determine the prevalence of cranial ultrasound abnormalities and to identify variables that affect the risk of these abnormalities in very low birthweight infants (VLBW) from preeclamptic and normotensive mothers. To investigate the influence of intrauterine growth restriction on the cerebral ultrasound findings. Methods: A cohort of all inborn VLBW infants admitted to NICU at University Hospital-Botucatu School of Medicine-UNESP from January 2009 to December 2013. Infants who was not assessed by cranial ultrasound screening were excluded. Two groups of infants: 1: Preeclamptic mothers (PE) and 2: Normotensive mothers were compared regarding gestational and neonatal data. Primary outcome: cranial ultrasound abnormalities (intraventricular hemorrhage grades I to IV and periventricular leukomalacia). Logist regression analyses were used to identify risk factors for ultrasound abnormalities. Results: A total of 381 VLBW infants were studied, 151 born to preeclamptic mothers and 230 from normotensives. The prevalence of abnormal ultrasound findings was 39%, with lower rate in PE group (30% vs 45%; p=0,007). In PE group the gestational age was higher, intrauterine growth restriction was very common and neonatal morbidity was lower. PE was not an independent risk or protective factor for cranial ultrasound abnormalities on logistic regression analysis. Antenatal magnesium sulphate therapy, chorioamnionitis and intrauterine growth restriction were not associated with ultrasound findings. Gestational age and cesarean delivery were protective factors, whereas surfactant administration, inotropic use within the first 72 hours of life, and neonatal infection were associated with increased risk of cranial ultrasound ...
136

Avaliação do tecido mamário em mulheres na pós-menopausa usuárias de isoflavona da soja

Delmanto, Armando [UNESP] 30 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-30Bitstream added on 2014-06-13T18:47:00Z : No. of bitstreams: 1 delmanto_a_dr_botfm.pdf: 571026 bytes, checksum: 2efa82a630b3a102bd0c2beed1370eec (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Avaliar o efeito da isoflavona da soja sobre o tecido mamário em mulheres na pós-menopausa. Trata-se de estudo clínico, prospectivo, randomizado, duplo-cego, placebo controlado, envolvendo 80 mulheres na pós-menopausa com sintomas vasomotores, idade entre 45 a 70 anos, acompanhadas no Ambulatório de Climatério e Menopausa da Faculdade de Medicina de Botucatu-Unesp, de janeiro de 2005 a dezembro de 2006. Na randomização, 40 pacientes receberam 100 mg isoflavona da soja/dia (duas cápsulas de 125 mg de extrato seco de glicine Max) e 40 pacientes placebo (duas cápsulas de lactose) durante 10 meses. A densidade mamária (DM) foi avaliada pela mamografia e o parênquima mamário pela ultrassonografia de mamas no início e após dez meses de seguimento. Para análise estatística foram utilizados o teste t-Student, ANOVA, teste de Mann-Whitney e teste do Qui-Quadrado. Na comparação das características clínicas iniciais entre os grupos de usuárias de isoflavona e placebo, não houve diferenças significantes, com valores médios de idade de 55,1±6,0 e 56,2±7,7 anos, tempo de menopausa de 6,6±4,8 e 7,1±4,2 anos e IMC de 29,7±5,0 e 28,5±4,9 kg/m2, respectivamente (p>0,05). Concluíram o estudo 32 pacientes sob isoflavona e 34 sob placebo. Na comparação da densidade mamográfica entre os momentos inicial e final, não houve diferença estatisticamente significativa. Na avaliação do parênquima mamário pela ultrassonografia, não houve diferença entre os grupos. Na comparação entre os momentos dentro de cada grupo, não foram constatadas diferenças significativas nos parâmetros da mamografia e ultrassonografia. No período de 10 meses, o uso de isoflavona de soja não modificou o tecido mamário, avaliado pela mamografia e ultrassonografia, em mulheres na pós-menopausa / To evaluate the effect of soy isoflavone on breast tissue in postmenopausal women. This study is a prospective, randomized, double-blind, placebo-controlled trial involving 80 postmenopausal women with vasomotor symptoms, aged 45-70 years, followed in Climacteric and Menopause Clinic of the Botucatu Medical School-UNESP, from January 2005 to December 2006. At randomization, 40 patients received 100 mg of soy isoflavone/day (two capsules of 125 mg standardized soy extract, Glicine max) and 40 patients, placebo (two capsules of lactose) for 10 months. The breast density was evaluated by mammography and breast parenchyma by ultrasound, at baseline and after ten months of follow-up. The Student t-test, ANOVA, Mann-Whitney and Chi-Square were used in the statistical analysis. In comparison of baseline clinical characteristics between the isoflavone and placebo groups, there were no significant differences, with mean age of 55.1 ± 6.0 and 56.2 ± 7.7 years, duration of menopause 6.6 ± 4.8 and 7.1 ± 4.2 years and BMI 29.7 ± 5.0 and 28.5 ± 4.9 kg/m2, respectively (p> 0.05). Concluded the study, 32 patients on isoflavone and 34 in the placebo group. In comparison in mammographic density (MD) between moments, baseline and final, there was no difference statistically significant. In the evaluation of breast parenchyma by ultrasound, there was no difference between groups. In comparing the moments within each group, there were no significant differences in the parameters of mammography and ultrasound. In 10 months, the use of soy isoflavone did not affect breast tissue, as assessed by mammography and ultrasound, in postmenopausal women
137

Avaliação ultrassonográfica hepática ao modo-B, dúplex e tríplex Doppler de cães com sobrepeso e obesos / B-mode, duplex and triplex Doppler sonography of the liver in overweight and obese dogs

Belotta, Alexandra Frey [UNESP] 09 February 2015 (has links) (PDF)
Made available in DSpace on 2015-08-20T17:09:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-09. Added 1 bitstream(s) on 2015-08-20T17:26:41Z : No. of bitstreams: 1 000840460.pdf: 1102877 bytes, checksum: 17858856958860c6204534d00c080571 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O atendimento de cães com sobrepeso e obesos na rotina clínica de animais de companhia tem sido cada vez mais frequente. O objetivo do presente estudo foi avaliar as alterações hepáticas parenquimatosas e hemodinâmicas, por meio da ultrassonografia bidimensional e Doppler, em três grupos de cães com diferentes escores de condição corporal - G1 (peso ideal/controle), G2 (sobrepeso) e G3 (obesos) -, sem doenças hepáticas por outras causas de base. Houve correlação positiva entre o G3 e os seguintes fatores: aumento da ecogenicidade do parênquima hepático, aumento das dimensões hepáticas, hiperlipidemia, e morfologia anormal da onda da veia hepática (VH). Diferença significativa na velocidade média do fluxo portal (Vméd.VP) foi observada entre G1 (17,23 ± 3,7cm/s) e G3 (13,66 ± 2,56cm/s), no volume do fluxo portal (VFVP) entre G1 (32,69 ± 11,86mL/min/kg) e G2 (19,58 ± 7,68mL/min/kg) e entre G1 e G3 (15,22 ± 8mL/min/kg), no índice hepatorrenal entre G2 (1,1 ± 0,29) e G3 (1,28 ± 0,22), nos níveis séricos de fosfatase alcalina (FA) entre G1 e G3, de gama glutamiltransferase (GGT) entre G1 e G2 e de colesterol entre G1 e os demais grupos. Não houve diferença significativa no índice de congestão portal (ICP), no índice de resistividade da artéria hepática (IRAH), no diâmetro e área da veia porta e nos níveis séricos de alanina aminotransferase (ALT) e triglicérides, entre os grupos. Concluiu-se que a obesidade pode levar ao desenvolvimento de alterações parenquimatosas e hemodinâmicas no fígado de cães / Veterinary care of overweight and obese dogs in small animal clinical sciences has become increasingly common. The aim of the present study was to investigate, using two dimensional and Doppler sonography, parenchymal and hemodynamic changes in three groups of dogs, according to body score condition (G1, ideal body weight/control; G2, overweight; G3, obese), without hepatic diseases due to other causes. A positive correlation was found between G3 and the characteristics described below: increased liver echogenicity, hepatomegaly, hiperlipidemia and abnormal hepatic vein Doppler waveform pattern. There was statistical difference in the mean portal blood flow velocity between G1 (17,23 ± 3,7cm/s) and G3 (13,66 ± 2,56cm/s), in the portal blood flow between G1 (32,69 ± 11,86mL/min/kg) and G2 (19,58 ± 7,68mL/min/kg) and between G1 and G3 (15,22 ± 8mL/min/kg), in the hepatorenal index between G2 (1,1 ± 0,29) and G3 (1,28 ± 0,22), in serum levels of alkaline phosphatase (ALP) between G1 and G3, in levels of gamma glutamyltranspeptidase (GGT) between G1 and G2 and in levels of cholesterol between G1 and the other groups. There was no statistical difference in the portal vein congestion index, hepatic artery resistance index, portal vein diameter and area and on serum levels of alanine aminotransferase (ALT) and triglycerides between the groups. It was concluded that obesity may be responsible for the development of parenchymal and hemodynamic changes in dog's liver
138

Ultrassonografia para bloqueios periféricos em crianças: revisão sistemática e metanálise de ensaios clínicos randonizados / Ultrasound guided nerve blockade in children : a meta-analysis of randonized clinical trials

Cabral, Lucas Wynne [UNESP] 26 February 2015 (has links) (PDF)
Made available in DSpace on 2016-07-01T13:10:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-26. Added 1 bitstream(s) on 2016-07-01T13:14:07Z : No. of bitstreams: 1 000864068.pdf: 1262302 bytes, checksum: 4c6431d5e7e0e90796d45aa103531bb2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Introdução: acredita-se que a anestesia regional guiada por ultrassonografia (USG) pode melhorar a eficácia dos bloqueios de nervos periféricos e reduzir as complicações na população pediátrica, porém essa hipótese ainda não foi previamente testada de forma quantitativa. Objetivo: a proposta desta revisão sistemática de ensaios clínicos randomizados (ECR) foi avaliar se o uso da ultrassonografia em pediatria melhoraria a taxa de sucesso dos bloqueios e reduziria o índice de complicações comparativamente a outros métodos tradicionais de localização de nervos. Métodos: a pesquisa sistemática, extração dos dados, avaliação crítica e análise conjunta dos dados seguiram as recomendações para a realização de revisões sistemáticas propostas pela Colaboração Cochrane e pela declaração PRISMA. A estratégia de busca incluiu as bases CENTRAL, EMBASE, Medline e Lilacs. A última pesquisa foi realizada em novembro de 2014. O risco relativo (RR) e a diferença média (DM), com seus respectivos intervalos de confiança de 95% (IC 95%), foram calculados utilizando-se o programa estatístico Revman para dados dicotômicos e contínuos, respectivamente. Resultados: onze ensaios clínicos randomizados, publicados entre 2004 e 2013, perfazendo um total de 634 pacientes, cumpriram os critérios de inclusão. A qualidade metodológica foi considerada moderada. Houve um pequeno benefício da ultrassonografia na taxa de sucesso (RR 1,19; IC 95% 1,07-1,32) que foi variável de acordo com a região anatômica avaliada, associado a uma redução na necessidade de analgesia no pós-operatório com o uso da ultrassonografia (RR 0,2; IC 95% 0,11-0,34). Apenas uma complicação foi reportada nos estudos incluídos. Uma punção vascular em um paciente do grupo controle durante realização do bloqueio ílio-inguinal/ílio-hipogástrico (II/IH). Conclusão: existe moderada evidência de que a ultrassonografia quando utilizada para... / Background: it has been suggested that ultrasound-guided regional anesthesia could improve the blockade efficacy and decrease complication rates in the pediatric population, but this hypothesis has not previously been adequately tested in a quantitative manner. Aim: the purpose of this systematic review of randomized clinical trials (RCT) is to assess whether the use of ultrasonography in the pediatric population has advantages over any other method of nerve location, such as the anatomical landmark-based technique, paraesthesia or use of an electrical nerve stimulator. Methods: the systematic search, data extraction, critical appraisal and pooled analysis were performed according to the Cochrane Handbook and PRISMA guidelines. The search strategy included the CENTRAL of the Cochrane Library, Medline, EMBASE, and Lilacs. The date of the last search was November 5, 2014. The relative risk (RR), mean difference (MD) and their corresponding 95% confidence intervals (95% CIs) were calculated using the Revman statistical software for dichotomous and continuous outcomes, respectively. Results: eleven randomized, clinical, controlled trials (published between 2004 and 2013) with a total 634 patients met the inclusion criteria. The methodological quality of the included studies was considered regular. There was a slight benefit of ultrasound to the success rate (RR 1.19, 95% CI 1.07 to 1.33), which was variable according to the anatomical region studied and a more important reduction of the analgesia requirement in the postoperative period with the use of ultrasound for peripheral nerve blocks (RR 0.2, 95% CI 0.11-0.34). There was only one complication reported (blood vessel puncture in one control group). Conclusions: there is moderate evidence that the use of ultrasound-guided peripheral nerve block in children reduces the number of patients requiring additional analgesia in the postoperative period and ...
139

Análise comparativa de técnicas de compressão aplicadas a imagens médicas usando ultrassom

Zimbico, Acácio José 18 March 2014 (has links)
CAPES / A área de compressão de imagem é de grande importância para aplicações médicas. As técnicas de compressão têm sido muito estudadas por permitirem representar de forma eficiente os dados, reduzindo o espaço necessário para armazenamento e minimizando a demanda na transmissão através de canais de comunicação. A técnica de compressão JPEG usa a transformada discreta de cossenos bidimensional e as técnicas Joint Photographic Experts Group 2000 (JPEG2000), Set Partitioning in Hierarchical Trees (SPIHT) e Embedded Zerotree Wavelet (EZW) usam a Transformada Wavelet bidimensional. Neste trabalho, uma análise comparativa é feita usando as métricas Mean Squared Error (MSE), Peak Signal to Noise Ratio (PSNR), Cross Correlation (CC) e Structural Similarity (SSIM) assim como uma avaliação indireta de esforço computacional através do tempo de processamento. A análise usando a técnica de compressão JPEG usando blocos de tamanhos diferentes permite concluir sobre a influência da frequência central dos transdutores ultrassônicos nos detalhes da imagem assim como concluir que o uso de blocos de tamanho 8x8 e 16x16 pixeis tem o melhor desempenho que o uso de blocos de menos tamanho. Adicionalmente, ao avaliar matrizes de quantização alternativas propostas por Hamamoto, Veraswamy e Abu para a técnica de compressão JPEG introduzem melhorias na qualidade da imagem de ultrassom reconstruída quando comparadas a matriz de quantização tradicional considerada taxa de compressão constante na comparação. Para técnicas usando a transformada wavelet foi possível observar o impacto significativo na qualidade da imagem de ultrassom reconstruída em função dos filtros utilizados. Finalmente, pode-se concluir que o algoritmo JPEG2000 apresenta o melhor desempenho em relação à qualidade de imagem e ao tempo de processamento quando comparado com os algoritmos JPEG, SPIHT e EZW. / The area of image compression is of great importance for medical applications. Compression techniques have been studied for allowing to efficiently representing the data, reducing the required storage space and minimizing the demand on transmission through communication channels. The JPEG compression technique uses a two-dimensional discrete cosine transform and techniques Joint Photographic Experts Group 2000 (JPEG2000), Set Partitioning in Hierarchical Trees (SPIHT) and Embedded Zerotree Wavelet (EZW) use the two-dimensional wavelet transform. In this work, a comparative analysis is made using the metrics Mean Squared Error (MSE), Peak Signal to Noise Ratio (PSNR), Cross Correlation (CC) and Structural Similarity (SSIM) as well as an indirect assessment of computational effort through time processing. The analysis using the JPEG compression technique using blocks of different sizes allows us to conclude on the influence of the center frequency of the ultrasonic transducers in the details of the image so as to conclude that the use of blocks of size 8x8 and 16x16 pixels has better performance than the use of note less size. Additionally, in evaluating alternative quantization matrices proposed by Hamamoto, Veraswamy and Abu for JPEG compression technique is concluded that these introduce improvements in the quality of reconstructed ultrasound image when compared to traditional matrix quantization considered that given compression rate in comparison. Techniques for using the wavelet transform have been possible to observe a significant impact on the quality of the ultrasound image reconstructed on the basis of the filters used. Finally, it was concluded that the JPEG2000 algorithm has the best performance with respect to image quality and processing time compared with JPEG, EZW and SPIHT algorithms.
140

Nanoencapsulação de curcumina em polímeros biodegradáveis/biocompatíveis

Buzanello, Rosana Aparecida da Silva 25 March 2013 (has links)
CAPES; CNPq / A curcumina tem potencial para substituir corantes artificiais considerados nocivos à saúde humana, contudo sua aplicação industrial se torna um desafio devido à sua sensibilidade frente a agentes externos e sua baixa solubilidade em água. O processo de nanoencapsulação em polímeros biodegradáveis e biocompatíveis é uma alternativa promissora para viabilizar a utilização da curcumina. Neste trabalho, a técnica de miniemulsificação/evaporação do solvente foi utilizada para obtenção de nanopartículas de polímeros biodegradáveis/biocompatíveis (poli(L-ácido lático) (PLLA) e Eudragit S100 (poli(metacrilato de metila-co-ácido metacrílico)) contendo curcumina. Um planejamento fatorial completo (2k) para quatro variáveis experimentais foi realizado a fim de avaliar o diâmetro médio e índice de polidispersão de tamanhos das nanopartículas de PLLA sem adição da curcumina. Os resultados demonstram a existência de interações complexas entre as variáveis avaliadas e que, de um modo geral, a polidispersão de tamanhos é menos sensível às mudanças nas condições experimentais do que o diâmetro médio. A metodologia de quantificação por espectrofotometria UV-Vis foi avaliada quanto às figuras de mérito em relação à linearidade, especificidade, exatidão, precisão e limites de detecção e quantificação. Os estudos de validação possibilitaram garantir com segurança os resultados obtidos para os valores de recuperação percentual e de eficiência de encapsulação da curcumina nas nanopartículas. Para a nanoencapsulação da curcumina, foi avaliada a influência da concentração de curcumina, do tipo de surfatante e dos polímeros encapsulantes (PLLA e Eudragit S100) sobre a morfologia das nanopartículas, eficiência de encapsulação e a recuperação percentual, parâmetro este que mede a perda de curcumina durante o processo de encapsulação. A adição de curcumina acima de 3%massa levou a menores recuperações percentuais, contudo sem prejudicar a eficiência de encapsulação. O uso de lecitina de soja, um surfatante biocompatível, levou a eficiências de encapsulação superiores do que quando comparado com o lauril sulfato de sódio. Da mesma forma, a recuperação de curcumina diminuiu quando foi utilizado Eudragit S100 em comparação ao PLLA, possivelmente devido à baixa interação entre os grupos polares de ácido metracrílico e a curcumina. As análises de espectroscopia de infravermelho e de calorimetria diferencial de varredura sugeriram que a curcumina foi encapsulada no interior das nanopartículas e se encontram dispersas na matrix polimérica em sua forma amorfa. O processo de miniemulsificação/evaporação do solvente se mostrou uma técnica robusta para a obtenção de nanopartículas contendo curcumina já que altos valores de eficiência de encapsulação foram encontrados para diferentes condições experimentais. / Curcumin can potencially substitute synthetic dyes considered harmful to human health. However, its susceptibility to external agents and very low water solubility turn its industrial application into a challenge. The nanoencapsulation of curcumin in biocompatible, biodegradable polymers is a promising alternative to enable the use of curcumin. In this work, the miniemulsification/solvent evaporation technique was used to obtain nanoparticles composed by biodegradable/biocompatible polymers (poly(L-lactic acid) (PLLA) and Eudragit S100 (poly(methyl methacrylate-co-methacrylic acid)) containing curcumin. A full factorial experimental design (2k) to four variables was carried to evaluate the Z-average diameter and polydispersity index of PLLA nanoparticles without curcumin. Results demonstrated the existence of complex relationships between the experimental variables and also that the polidispersion index is less sensitive to the change in the experimental conditions than the particles diameter. The methodology for quantification by UV-Vis spectrophotometry was evaluated in respect to the figures of merit: linearity, specificity, accuracy, precision and limits of detection and quantification. Curcumin recovery and the encapsulation efficiency can be safely determined by this methodology. The curcumin nanoencapsulation was studied and the influence of curcumin concentration, type of surfactant and the encapsulant polymers (PLLA and Eudragit S100) on the nanoparticles morphology, encapsulation efficiency and curcumin recovery (defined as the lost of curcumin during the encapsulation process) were evaluated. The addition of curcumin above 3%weight led to low recovery values but there was no effect on the encapsulation efficiency. The use of soybean lecithin a biocompatible surfactant led to encapsulation efficiencies higher than when sodium lauryl sulfate was used. Similarly, the curcumin recovery decreased when Eudragit S100 were used probably due to the low interaction between the polar groups of methacrylic acid and curcumin. Infrared spectroscopy and differencial scanning calorimetry strongly suggested that curcumin was encapsulated within the nanoparticles and is dispersed in the polymer matrix in as amorphous state. Results demonstrated that miniemulsification/solvent evaporation is a robust technique to obtain nanoparticles containing curcumin since high encapsulation efficiencies were achieved for different experimental conditions.

Page generated in 0.0869 seconds