• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 6
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 15
  • 12
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Comparison of RF Heating in ASDEX Upgrade and ITER

Blennå, Axel, Kalldas, Mark January 2022 (has links)
The increased effects of global warming have been a driving force to further research and develop sustainable energy sources, such as fusion. In this study, two different fusion devices are compared in terms of ion cyclotron resonance heating (ICRH)of plasma. The two devices are the tokamaks ASDEX Upgrade and not yet built ITER. To make the comparison, ICRH was simulated in the two tokamaks using the FEMIC code. ASDEXUpgrade was simulated with a deuterium plasma and ITER was simulated both with a deuterium and a deuterium-tritium plasma. In all scenarios a 3% minority species concentration,consisting of helium-3, was introduced. The obtained results showa higher and more centered wave absorption in ITER, compared to ASDEX Upgrade. This is mainly due to the size difference of the tokamaks. The smaller plasma radius of ASDEX Upgrade allowed for more wave reflection in the plasma, resulting in standing waves that formed eigenmode patterns. For simulationsin ITER, the waves were absorbed before they could be reflected in the plasma. Instead of standing waves and eigenmode patterns,the waves behaved as beams, propagating in a narrow region of the plasma. This indicates that ITER is more effective in terms of ICRH, as the absorption is greater and more focused to the center, minimizing power losses to the surroundings. / De ökade konsekvenserna av den globala uppvärmningen har varit en drivkraft för fortsatt forskning och utveckling av hållbara energikällor, bland annat fusion. I den här studien jämförs två olika fusionsanläggningar med avseende på joncyklotronresonansuppvärmning (ICRH) av plasma. De två anläggningarna är tokamakerna ASDEX Upgrade och ännu inte byggda ITER. För att göra jämförelser simulerades ICRH i de två tokamakerna med hjälp av FEMIC-koden. ASDEX Upgrade simulerades med ett deuteriumplasma och ITER simulerades med både ett deuteriumoch ett deuterium-tritiumplasma. För alla scenarier introducerades en 3% minoritetskoncentration av helium-3. Resultaten visar en högre och mer centrerad vågabsorption i ITER jämfört med ASDEX Upgrade. Detta beror framför allt på storleksskillnaden mellan tokamakerna. Den kortare plasmaradien av ASDEX Upgrade tillät mer reflektion i plasmat, vilket resulterade i stående vågor som bildade egenmodsmönster. För simuleringar i ITER absorberades vågorna innan de kunde reflekteras i plasmat. I stället för stående vågor och egenmodsmönster uppförde vågorna sig som strålar som propagerade över en smal region i plasmat. Det här indikerar att ITER är mer effektiv med avseende på ICRH, då absorptionen re och mer centrerad, vilket minimerar effektförluster till omgivningen. / Kandidatexjobb i elektroteknik 2022, KTH, Stockholm
62

Data Rate Upgrade of the DFCS Waveform

Walthall, David 10 1900 (has links)
International Telemetering Conference Proceedings / October 26-29, 1992 / Town and Country Hotel and Convention Center, San Diego, California / New tracking/control system requirements demand that the present DFCS/GRDCUS/MTACS data link bit rate be increased. A possible method for achieving this increase is to select two additional 31-bit chip code patterns that are orthogonal to the present chip codes, and to each other. This method will not require any more bandwidth than the present 10 MHZ used. This method suggest that each of the four chip code patterns are assigned a two bit value ie: 00, 01, 10, 11. At present, the two correlated chip codes represent data in a pulse position method. No data is contained in which of the two chip codes actually correlated. This new method suggest each of the four chip code patterns will still perform the pulse position modulation and provide two additional bits of data. These additional two bits of data will up the data rate of the link by 100 percent.
63

Původní rating před oznámením změny ratingu a rozdílný vliv zvýšení a snížení ratingu na akcie společnosti / Does the Role of the Rating Prior to the Announcement Explain Different Influence of Credit Rating Downgrades and Upgrades on Stock Prices?

Sedlář, Jan January 2015 (has links)
The thesis examines whether the role of credit rating prior to the announcement of credit rating change is the neglected factor explaining in large extent the paradox investigated in prior papers that downgrades influence the stock prices of company but upgrades not. It is motivated by the notion that credit rating changes from low credit rating classes influence the stock price of company more distinctively than changes from higher credit rating classes and there is proportionally more downgrades from low credit rating classes than upgrades. The large sample of credit rating changes including proportionally more upgrades from low credit rating classes than downgrades is collected and the results suggesting the influence of downgrades on stock prices of company and any influence of upgrades persist. Furthermore when controlled for credit rating prior to the announcement of credit rating change, magnitude of credit rating change, crossing the investment-speculative barrier, credit rating changes within and across credit rating categories, consecutive credit rating changes in the same direction and industry sector of issuer all the results are consistent with the original conclusions proposing significant stock price reaction to announcements of credit rating downgrades and no stock price response to...
64

Characterization of γ-rays at MAST

Blom, Erik January 2019 (has links)
The γ-ray characterizing possibility of the neutron collimated flux monitor (in short, Neutron Camera) at the Mega Ampere Spherical Tokamak (MAST) is explored. Typically used to monitor neutron emission, the Neutron Camera has excellent neutron/γ-ray discrimination properties and thus presents the opportunity to measure spatially and temporally resolved γ-ray emission - a possibility of an additional fusion diagnostics method with already existing equipment. An Online Data Analysis (ODA) code was used to analyze the data on γ-rays from several plasma discharges with similar plasma parameters. A high statistics temporal distribution of the γ-ray emission and a lower statistics spatial distribution were analyzed. However, the low energy resolution and range for the Neutron Camera γ-ray measurements revealed few conclusive results on the origin of the higher energy γ-rays. Detection systems with higher energy resolution and range are suggested for an extensive analysis of γ-ray emission at MAST Upgrade.
65

產品過時恐懼與購買間隔對智慧型手機置換決策之研究 / Fear of Obsolescence and Purchase Interval: A Study of Smartphone Replacement Decisions

鄭綦成, Cheng, Chi Cheng Unknown Date (has links)
自從智慧型手機普及以來,儼然已經成為每個人生活的必需品。根據資策會的報告,2014年臺灣智慧型手機的普及率已達65.4%,且每年都快速地攀升。正因為有如此龐大的需求和商機,智慧型手機廠商不斷地針對產品進行升級,提升產品的技術規格、增加許多令人眼睛為之一亮的創新功能、改善外型款式讓手機更加新潮時尚⋯⋯,也因為智慧型手機市場有如此多的選擇,消費者越來越容易產生產品過時恐懼,導致智慧型手機的平均換機時間越來越短,不再像以往一樣使用到損壞為止。 本研究即以智慧型手機為例,透過文獻回顧擬定假說後,再以實證資料分析新奇追求、從眾行為及獨特性需求三種消費者行為特性對產品過時恐懼的影響;產品過時恐懼對消費者智慧型手機相對持有時間比的影響;新奇追求及相對持有時間比對智慧型手機產品升級意願的影響,以及相對持有時間比對智慧型手機品牌面置換決策(再購買意願、轉換意願)的影響。 本研究所得到之研究結論如下: 1. 新奇追求、從眾行為及獨特性需求越強,皆會使消費者心理性過時恐懼越強 2. 消費者的從眾行為越強,其經濟性過時恐懼越強 3. 心理性過時恐懼及技術性過時恐懼越強會使相對持有時間比越大 4. 消費者的新奇追求程度越高,則產品升級意願越高 5. 消費者的相對持有時間比越大,則產品升級意願也越高
66

Dificuldades para a atualização de versão do sistema ERP R/3 da SAP: estudo de caso em empresa do segmento de bebidas

Valentim, Onivaldo Aparecido 05 March 2010 (has links)
Made available in DSpace on 2016-06-02T19:51:43Z (GMT). No. of bitstreams: 1 2979.pdf: 2470713 bytes, checksum: cb66cbd2392299db2bc5224246b85d95 (MD5) Previous issue date: 2010-03-05 / Many companies which adopted ERP systems in the past are frequently reluctant tostart new projects to upgrade the technology to newer versions. The decision is difficult due to thelong time of the project, the amount of financial investments and internal workforcerequired for the job, which are usually similar to the original ERP implementation. This work has asproposal a research and analisys of the apparently large demand of resources necessary to upgradethe versions of ERP R/3 systems. Firstly, a review in literature is made to present the arquitecture,characteristics and concepts of modules and funcionalities of these ERPs systems. It is alsoincluded the study of the life cicle of ERPs systems and its interfaces with legacy systems. Insequence, the versions upgrade subject is explored, where this author suggests that upgrade ofversions gives new life to ERPs systems and discuss how the suppliers share the ERP´s market andfinally explore the kinds of upgrades available for these systems. After these studies, twoquestionnaires are made to obtain data. This research is a Unique Case study type and has asobjective to describe the behavior of critic factors of implementation during an upgrade of ERPsystems, verifying if the demands are justified. / As empresas que necessitam fazer atualizações em seus sistemas ERP SAP R/3questionam os tempos, os valores e a utilização dos recursos humanos e estruturais solicitados parafazer estas atualizações. As demandas necessárias se aproximam aos de uma implementação. Estetrabalho tem como proposta a pesquisa e análise das dificuldades para atualizar as versões dosistema ERP R/3 da SAP. Inicialmente uma revisão bibliográfica é feita para dimensionar aabrangência dos sistemas ERPs e apresentar um referencial teórico de conceitos sobre os sistemas degestão empresarial; sobre a arquitetura e as características dos sistemas ERPs; sobre os conceitos demódulos e funcionalidades que estão diretamente relacionados a estes sistemas; sobre a evolução eciclo de vida destes sistemas; sobre a integração que estes sistemas têm com os sistemas legados. Nasequência é explorado o assunto atualização de versão, onde o autor sugere que as atualizações deversões dão sobrevida aos sistemas ERPs; a participação do mercado dos fornecedores de sistemasERPs; e as formas utilizadas para se atualizar o sistema ERP R/3 da SAP. Com base na pesquisa enos assuntos explorados são gerados os instrumentos de coleta de dados. Para execução destetrabalho realizou-se um estudo de caso único com objetivos descritivos visando analisar se algunsdos fatores críticos de implementação de sistemas ERPs se comportam da mesma forma naatualização de versão, justificando as demandas.
67

Reconstruction des photons et recherche d’un second boson de Higgs dans le canal di-photon au sein de l’expérience CMS au LHC / Photon reconstruction and search for a second Higgs boson in the diphoton channel with CMS experiment at LHC

Courbon, Benoit 18 October 2016 (has links)
Une particule compatible avec le boson de Higgs du modèle standard de la physique des particules a été découverte au grand collisionneur de hadrons (LHC) en juillet 2012 par les expériences Atlas et CMS. A ce jour, l'ensemble des mesures des couplages de ce boson de Higgs sont compatibles avec ceux prédits par le modèle standard. Toutefois le modèle standard possède des limitations et d'autres théories, telles la supersymétrie, ont été bâties afin de pallier à ces manques. Certaines de ces théories prédisent en particulier un secteur scalaire enrichi avec la présence de bosons de Higgs additionnels.D'un point de vue expérimental, le canal de désintégration du boson de Higgs en deux photons offre une signature claire et permet d'explorer le secteur de Higgs avec une grande précision. Les travaux présentés dans cette thèse ont été effectués dans le cadre de l'expérience CMS au LHC.La première partie est dédiée à l'étude de la reconstruction expérimentale des photons. Tout d'abord, une méthode de correction en énergie des photons est exposée. Puis des prospectives concernant l'évolution de la qualité de leur reconstruction avec le vieillissement du détecteur sont présentées.La deuxième partie fait l'objet de la recherche d'un second boson de Higgs de basse masse(en dessous de 110 GeV) dans le canal di-photon. Les résultats complets obtenus avec le jeu de données collecté en 2012, ayant fait l'objet d'une publication officielle, sont tout d'abord présentés. Les premiers résultats obtenus avec le jeu de données collecté en 2015 sont enfin introduits / A particle compatible with the Standard Model Higgs boson has been discovered at the Large Hadron Collider (LHC) in July 2012 by Atlas and CMS experiments. All the couplings measurements are so far compatible with those predicted by the Standard Model. However, this model is not able to address several fundamental physics issues and theories beyond the Standard Model, such as supersymmetry, have been proposed to address these questions. Some of them predict an extended Higgs sector with additional scalar or pseudoscalars at low mass.On the experimental point of view, the diphoton decay channel provides a clear signature and allows us to explore the Higgs sector with high precision.The studies presented in this thesis have been performed using the data collected by CMS at the LHC.The first part of the document is dedicated to photon reconstruction studies. First, a photon energy correction method is presented. Then, photon reconstruction performance is assessed in the context of the Phase I and Phase II detector upgrades, in high luminosity conditions.The second part of the document is dedicated to the search for an additional light Higgs boson (with a mass below 110 GeV) in the diphoton channel. First, the official results corresponding to the full 2012 dataset are exposed. Finally, results corresponding to 2015 data are presented
68

Caractérisation de détecteurs à plaques résistives de verres de basse résistivité en vue de la mise à niveau de CMS / Characterisation of low resistivity glass resistive plate chambers for the CMS upgrade

Lagarde, François 20 October 2017 (has links)
La mise à niveau du détecteur CMS (Upgrade Phase-2) en 2024 prévoit l'installation de nouveaux détecteurs à plaques résistives (RPC) dans les 2 secteurs les plus externes et les plus vers l’avant (RE3/1 et RE4/1) des bouchons. Des RPC en verre de basse résistivité (GRPC) ont été proposées afin d'instrumenter ces secteurs où le flux de particules sera de l’ordre du kHz/cm², valeurs pour lesquelles les RPC actuelles de CMS ne sont pas efficaces. Cette thèse porte sur l'étude et la caractérisation de ces GRPC, de leur électronique de lecture associée et de leur résistance aux irradiations. Deux méthodes de production de chambres de taille moitié des chambres finales à partir de pavages de verres de taille maximale 32*30cm² ont été élaborées et testées. Un nouveau circuit électronique (PCB) à bandes de détection non segmentées en êta et lues par des puces dédiées (PETIROC2A) est également présenté. Il permet grâce à des chronomètres numériques (TDC) de 25 picosecondes de résolution, une précision de l'ordre du centimètre sur la mesure de la position du passage des particules le long des bandes. Cette thèse décrit ces nouveaux dispositifs et présente les résultats obtenus avec ceux-ci lors de tests en faisceaux auprès des accélérateurs PS et SPS du CERN ainsi qu'au Gamma Irradiation Facility (GIF++). Cette étude montre que le verre de basse résistivité, bien que supportant les flux de particules, n'est pas la meilleure solution pour l'environnement de CMS car il nécessite un mélange gazeux différent pour fonctionner. Cependant, la nouvelle électronique a prouvé son adéquation à cet environnement et est maintenant considérée comme l'option privilégiée pour la mise à niveau de CMS / The installation of new resistive plate chamber detectors (RPCs) in the 2 most remote sectors (RE3 / 1 and RE4 / 1) of the CMS End-Caps is planned during the Phase-2 CMS upgrade in 2024. Glass Resistive Plate Chambers (GRPC) with low resistivity glass as electrodes have been proposed to equip these sectors. These detectors should sustain these zones' particle rate. The aim of this Thesis is to study and characterise these detectors, their associated readout electronics and their behaviour under radiations.Two ways of building half size chambers by tesselation of glass plates with maximal size 32*30cm² have been developped. A new PCB with strips readout read by dedicated ASICs (PETIROC2A) without eta segmentation is also described. It allows, thanks to a 25 ns time-resolution TDC to estimate the particle crossing position on the strip with a resolution of the order of cm. This manuscript describes all these devices and discusses the devices' performance measured in beam tests done at the CERN PS and SPS accelerator and at the Gamma Irradiation Facility (GIF++). This study shows that the low resistivity glass, though able to sustain the particule rate, is not the best option for the CMS upgrade. On the contrary, the tested electronic has been proven to fit the CMS upgrade requirements and is now considered as the baseline of the CMS End-Caps RPC upgrade project
69

Study of long-term sustained operation of gaseous detectors for the high rate environment in CMS / Etude du fonctionnement à long terme de détecteur gazeux pour l'environnement à haut flux de CMS

Merlin, Jérémie 25 April 2016 (has links)
Le spectromètre à muons de CMS doit permettre l'identification rapide et efficace des muons produits lors des collisions proton-proton au LHC. Cependant, à cause d'un environnement de détection extrême, seules les chambres à pistes cathodiques équipent actuellement les bouchons de CMS. Cette faiblesse dans le système de détection pourrait devenir problématique après l'amélioration du LHC. L'augmentation du taux de particules dans les bouchons va dégrader les performances du système de déclenchement L1 ainsi que l'efficacité de sélection des phénomènes physiques intéressants. Le but du programme d'amélioration de CMS est de maintenir le taux de déclenchement L1 tout en gardant une efficacité de sélection maximale. La collaboration CMS GEM propose d'équiper les régions vacantes des bouchons avec des détecteurs basés sur la technologie d'amplification des électrons dans un gaz (GEM), appelés GE1/1. Le sujet de thèse proposé par la collaboration CMS GEM a pour but de justifier le choix de la technologie GEM pour l'amélioration de CMS. Trois projets ont été suivis pendant la thèse. La première partie du projet de thèse consistait à mesurer précisément les caractéristiques fondamentales et les performances de détection des détecteurs triple-GEM produit par la technique simple-masque. Ces éléments sont essentiels pour s'assurer que les détecteurs GE1/1 pourront fonctionner en toute sécurité dans l'environnement des bouchons de CMS. Le deuxième projet consistait à prouver que les excellentes performances des détecteurs GE1/1 ne vont pas se dégrader pendant leur utilisation dans CMS. Cette étape comprend l'étude du fonctionnement à long terme des détecteurs GE1/1, en particulier le phénomène de vieillissement, qui inclue tous les processus physiques et chimiques qui provoquent la dégradation graduelle et permanente des performances de détection. Plusieurs tests de vieillissement ont été menés dans des zones d'irradiations spécifiques au CERN pour reproduire un minimum de 10 ans de fonctionnement réel dans l'environnement de CMS après la montée en puissance du LHC. Enfin, les excellentes propriétés mesurées lors de la phase de R&D ont permis de valider la technologie triple-GEM, qui fut ensuite approuvée par la collaboration CMS et le comité du LHC. La production de 144 grands détecteurs GE1/1 sera partagée entre différents sites de production à travers le monde. Le troisième projet de thèse fut donc le développement des principales étapes du contrôle qualité nécessaire pour assurer une production uniforme et une même qualité pour tous les détecteurs GE1/1. / The muon system of CMS aims to provide an efficient and fast identification of the muons produced in the proton-proton collisions. However, the forward region of the end-caps is only instrumented with Cathode Strip Chambers. This lack of redundancy will be problematic after the high-luminosity upgrade of the LHC (HL-LHC), for which the increase of the background rate would degrade the Level-1 trigger performance and thus the selection of interesting physics channels. The goal of the CMS muon upgrade is to maintain the L1 trigger rate with maximum selection efficiency in order to fully exploit the HL-LHC. The CMS GEM Collaboration has proposed to instrument the vacant highetaregion of the muon end-caps with Gas Electron Multiplier (GEM) detectors, called GE1/1chambers.The Ph.D. subject proposed by the CMS GEM Collaboration aims to demonstrate that the GE1/1technology is the most suitable choice for the upgrade of the muon end-caps. Three main researchprojects were conducted in this context. The first project included the precise measurement of the fundamental characteristics and the detection performance of the triple-GEM detectors produced with the single-mask technique. Those characteristics are essential to ensure that the detectors can operate in the forward region of CMS. The second project was focused on the long-term operation of GE1/1 detectors, in particular the study of the aging phenomenon, which includes all the processes that lead to a significant and permanent degradation of the performance of the detectors. Several aging tests were performed at the CERN irradiation facilities to prove that the GE1/1 chambers can operate during at least 10 yearsat HL-LHC without suffering from performance losses. The excellent properties measured during the R&D phase led to the approval of the GE1/1 project by the CMS Collaboration. The third project, conducted in the framework of the mass production,consisted of developing of the main steps of the Quality Control of the GE1/1 chambers.
70

Analysis of the Demonstrator Readout of the Liquid-Argon Calorimeter at the ATLAS Detector

Hils, Maximilian 22 October 2020 (has links)
Die laufenden Aufrüstungsarbeiten des Large Hadron Colliders haben das Ziel, die Luminosität der Teilchenkollisionen zu erhöhen. Die erhöhte Luminosität liefert zwar neue Möglichkeiten für Präzisionsmessungen und Teilchensuchen, stellt aber gleichzeitig eine große Herausforderung an die beteiligten Experimente. Aus diesem Grund wird auch der ATLAS-Detektor aufgerüstet. Der Fokus ist dabei, eine hohe Effizienz des Triggers sicherzustellen, der die interessanten Physikereignisse in Echtzeit auswählt. Dafür wird das Flüssig-Argon-Kalorimeter des ATLAS-Detektors mit einer neuen Ausleseelektronik ausgerüstet. Um die Funktionsfähigkeit zu testen, wurde ein Demonstrationsaufbau der zukünftigen Ausleseelektronik installiert und von 2014 bis 2018 parallel zur ATLAS- Datennahme betrieben. In dieser Arbeit werden die Daten, die mit dem Aufbau aufgezeichnet wurden, analysiert. Die neue Ausleseelektronik erlaubt es, komplexere Algorithmen zur Erkennung von Signal- und Untergrundereignissen zu nutzen. Es handelt sich dabei um Variablen zur Beschreibung der Form von elektromagnetischen und hadronischen Teilchenschauern im Flüssig-Argon-Kalorimeter. Die Effizienz dieser Variablen wird untersucht. Dabei wird nach Kombination mehrerer Variablen eine Untergrundunterdrückung hadronischer Jets von 75 % bei einer Elektronenerkennungseffizienz von 90 % erreicht. Die zukünftige, erhöhte Luminosität führt dazu, dass sich bei Teilchenkollisionen die Zahl der Ereignisse, die sich sowohl zeitlich als auch räumlich überlappen, erhöht. Der Effekt dieser Überlappereignisse hat Auswirkungen auf die Energierekonstruktion. Daher wird eine Untersuchung der Überlappereignisse durchgeführt, um eine möglichst genaue Kenntnis über diese zu erhalten. Für die Rekonstruktion aus den Signalen der im Detektor deponierten Energie stehen verschiedene digitale Signalfilter zur Auswahl. Die Performanz hinsichtlich der Signalerkennung dieser Algorithmen wird überprüft. Es zeigt sich, dass neue digitale Signalfilter zwar den Effekt des zeitlichen Überlapps von Detektorpulsen reduzieren, jedoch sehr sensitiv auf die genaue Pulsmodellierung sind. / The ongoing upgrade activities at the Large Hadron Collider aim for an increase of the luminosity in the particle collisions. The increased luminosity delivers new capabilities for precision measurements and searches for signatures of new physics. At the same time, challenges arise for the experiments. For this reason, the ATLAS detector is upgraded. The focus is on maintaining the high efficiency of the trigger that selects interesting physics events in real-time. Therefore, the Liquid-Argon calorimeter of the ATLAS detector is upgraded with new readout electronics. To evaluate the performance, a demonstrator readout was installed and operated in parallel to the data taking of the main readout between 2014 and 2018. In this thesis, the data recorded with the demonstrator is analyzed. The new readout electronics allow more sophisticated algorithms to distinguish between signal and background events. They are based on variables that describe electromagnetic and hadronic showers. The proposed shower-shape variables are studied concerning their trigger efficiency and background rejection power. With a combination of the shower-shape variables, a background rejection power of 75 % for hadronic jets is achieved while keeping the electron trigger efficiency at 90 %. The increase in luminosity will lead to an increase in in-time and out-of-time pile-up effects. These have an impact on the energy reconstruction. Therefore, pile-up events are investigated, to gain precise knowledge about their effects. For the energy reconstruction of the detector signals, different digital filter algorithms are available. The signal detection efficiency of these algorithms is examined. While new filter algorithms are capable of reducing the effect of out-of-time pile-up, they depend greatly on the correct phase of the pulse shape.

Page generated in 0.0545 seconds