• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 862
  • 16
  • 16
  • 15
  • 15
  • 11
  • 11
  • 7
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 886
  • 709
  • 587
  • 387
  • 327
  • 313
  • 102
  • 87
  • 80
  • 74
  • 70
  • 67
  • 66
  • 65
  • 64
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Influencia da estrutura celular e da geometria da amostra na taxa de transferencia de massa do processo de desidratação osmotica de banana nanica (Musa cavendishi) e de mamão formosa (Carica papaya L.)

Antonio, Graziella Colato 01 August 2018 (has links)
Orientador: Fernanda Elizabeth Xidieh Murr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-01T15:01:31Z (GMT). No. of bitstreams: 1 Antonio_GraziellaColato_M.pdf: 20605718 bytes, checksum: 362980c93a42ebc82ff465693650061b (MD5) Previous issue date: 2002 / Resumo: Neste trabalho foi estudada a transferência de massa na Banana Nanica (Musa cavendishi) e no Mamão Formosa (Carica papaya 1.) no processo de desidratação osmótica. Foi analisada a influência da geometria e estruturas celulares, para a verificação do mellior desempenho na transferência de massa. A etapa de desidratação osmótica foi conduzida com agitação constante de 80rpm e analisada através de um planejamento experimental fatorial 24-1com 3 repetições no ponto central para cada geometria estudada. As variáveis analisadas foram temperatura (30, 45 e 60°C), concentração da solução de sacarose (45, 55 e 65°Brix), concentração de ácido láctico (O, 0,05, 0,1M), e geometria da amostra (placa plana e cubo). As respostas analisadas foram perda de água, ganho de sólidos e atividade de água. A temperatura foi a variável que mais influenciou na perda de água e ganho de sólidos, seguida da concentração de sacarose da solução. A geometria de placa foi a que mais facilitou a perda de água no processo de desidratação osmótica tanto para a banana quanto para o mamão. O Modelo de Peleg e Azuara ajustaram-se bem os dados experimentais, sendo que os dados de equilibrio de perda de água que mais se aproximaram dos dados experimentais foram os calculado pelo Modelo de Azuara. Pela análise de imagens obtidas através da microscopia eletrônica de varredura foi possível verificar que as células da banana apresentam-se de forma alongada com presença de grânulos de amido e tanino, enquanto que as células do mamão apresentam-se forma oval. A geometria da amostra mostrou ser a variável que mais influenciou nas modificações ocorridas durante o processo de desidratação osmótica de ambas frutas, seguida da temperatura. / Abstract: In this work was studied mass transfer in banana (Musa cavendish) and papaya (Carica papaya L.) in osmotic dehydration process. It was analyzed the influence of geometry and cells structures to verify the best performance in mass transfer. Osmotic dehydration was carried on with constant agitation of 80 rpm and analyzed through a factorial experimental design 24-1with 3 repetitions of central point for each geometry. Analized variables were temperature (30, 45 and 60°C), sucrose concentration (3,5; 4,5 and 5,5 M), lactic acid concentration (O; 0,05 and O,lM) and sample geometry (fIat plate and cube). Analyzed responses were water 1055,solid gain and water activity. Water loss and solid gain were influenced more by temperature and after by sucrose concentration. In osmotic dehydration process, fIat plate geometry facilitated water loss in both banana and papaya. Peleg and Azuara's models fitted well to experimental data, but equilibrium data were better approached when they were calculated by Azuara's model. Analyzing obtained images through electronic microscopy scanning it was possible to verify that banana cells presented elongated shape with starch granules and tanine, while papaya cells presented egg-shaped. The variable that caused more influence in occurred changes during osmotic dehydration was sample geometry and after the temperature. / Mestrado / Mestre em Engenharia de Alimentos
62

Avaliação clinica, radiografica e microscopica de implantes endoosseos

Joly, Julio Cesar 29 May 2002 (has links)
Orientador : Antonio Fernando Martorelli de Lima / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T16:28:19Z (GMT). No. of bitstreams: 1 Joly_JulioCesar_D.pdf: 2169800 bytes, checksum: e5dd2662391b2be270fdf0a22cc9c1ce (MD5) Previous issue date: 2002 / Resumo: Este estudo avaliou as alterações clínicas, radiográficas e microscópicas de implantes de dois e um estágios. Para avaliação clínica e radiográfica foram selecionados implantes de transmucoso com 2,8 mm (grupo I) e 1,8 mm (grupo 11) de comprimento. Os parâmetros índice de Placa (IPI), índice de Sangramento OS}, Profundidade de Sondagem (PS), Nível da Margem Gengival (NMG), Nível Clínico de Inserção relativo (NCI-r) e Densidade Óptica (DO) foram obtidos no carregamento protético (4 meses) e 12 meses após-a implantação. O parâmetro radiográfico Nível Ósseo (NO) foi obtido na colocação dos implantes, 4 e 12 meses após a implantação. Para avaliação em microscopia eletrônica de varredura foram selecionados implantes de dois estágios revestidos com fosfato de cálcio (RBM) e implantes de um estágio revestidos com plasma de titânio (TPS). Os dados foram avaliados por análise de variância e pelo teste t pareado de Student para comparação entre os tempos e os grupos experimentais. Os resultados mostraram diferença significativa (P < 0,05) entre os tempos experimentais para os parâmetros PS, NCI-r e NO. Entre os grupos I e 11 houve diferença significativa para o NCI-r (P < 0,05), entretanto, não houve diferença significativa nos parâmetros IPI, IS, PS, NMG, DO e NO (P > 0,05). Não houve diferença significativa (P > 0,05) na extensão da fenda entre os sistemas de um e dois estágios. Os tratamentos proporcionaram diferentes características de superficiais. Os dois sistemas mostraram que há fenda entre os componentes do implante. A reabsorção óssea perimplantar ocorreu antes da aplicação da carga para a adaptação dos tecidos perimplantares e manutenção do espaço biológico, independente do comprimento do transmucoso / Abstract: This study evaluated clinical and radiographic changes produced by one-stage implants with different smooth portion lengths, as well as the gap microscopic aspects in both two- and one-stage implants. The sites were randomly assigned into group I: treated with 2.8 mm smooth neck portion implants (n=6) and group 11: treated with 1.8 mm smooth neck portion implants (n=6). The parameters Plaque Index (PU), 81eeding Index (BI), Probing Oepth (PO), Gingival Margin Level (GML), relative Clinical Attachment Level (r-CAL) and Optic Oensity (00) were measured in the loading (4 months) and 12 months after implant placement. The radiographic parameter Osseous Level (OL) was measured in the implant placement, in the loading and 12 months after. Two-stage implants coated with RBM and one-stage implants coated with TPS were evaluated by scanning electron microscopy. Analysis of variance and the paired Student-t test was applied to detect difference over time and between groups. The results showed significant differences (P < 0.05) between the evaluation periods for PO, r-CAL and OL. Between groups I and 11 was significant differences (P < 0.05) for r-CAL, however, no significant differences were found for PII, 81, PO, GML, 00 and OL. No significant differences (P > 0.05) were found regarding the gap extension between two- and one-stages systems. The treatments produced different surface roughness. Independently of system, there are gaps between the implants components. Bony loss occurred previous loading to support the soft tissues and maintain the biologic width irrespective of the smooth portion length / Doutorado / Periodontia / Doutor em Clínica Odontológica
63

Avaliação da união composito/dentina em função do tempo de condicionamento acido e sistema de união em dentes deciduos

Caldo-Teixeira, Angela Scarparo 05 May 2003 (has links)
Orientador : Regina Maria Puppin Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T08:28:15Z (GMT). No. of bitstreams: 1 Caldo-Teixeira_AngelaScarparo_M.pdf: 8636792 bytes, checksum: 7efc21de1fc884cb85703ee162977186 (MD5) Previous issue date: 2003 / Resumo: Este estudo teve por objetivo avaliar a resistência da união à microtração, o padrão de fratura obtido após o ensaio mecânico e a região da união compósito/dentina, em função de tempos de condicionamento ácido (7, 15 e 20s) e sistemas de união (Single Bond-SB; Prime & Bond 2.1 - P&B2.1; One Up Bond F-OUP e Clearfil SE Bond-CSE). Foram selecionados 138 molares decíduos, hígidos, extraídos por indicações ortodônticas, de crianças na faixa etária de 4 a 9 anos. Para o ensaio de resistência da união à microtração, foram selecionados 48 dentes, aleatoriamente distribuídos em 3 grupos de acordo com o tempo de condicionamento ácido e subdivididos em 4 subgrupos de acordo com o sistema de união, sendo (n=20): G1- 7s + SB; G2- 15s + SB; G3-20s + SB; G4- 7s + P&B2.1; G5- 15s + P&B2.1; G6- 20s + P&B2.1; G7- 7s + OUP; G8- 15s + OUP; G9- 20s + OUP; G10- 7s + CSE; Gll- 15s + CSE; G12- 20s + CSE. Os dentes foram transversalmente cortados na superfície oclusal, planificados até a obtenção de área plana em dentina. Os procedimentos de união foram realizados de acordo com a distribuição dos grupos, e a superfície restaurada com compósito odontológico Filtek Z250. Em seguida, as amostras foram cortadas nos sentidos vestíbulo-lingual e mésio-distal, para obtenção de corpos-de-prova com área de secção de aproximadamente 1mm2. Após o armazenamento por 24h, os corpos-de-prova foram submetidos ao ensaio de microtração em máquina de ensaio universal (Instron) à velocidade de O ,5mm/min. Os dados foram submetidos à Análise de Variância e ao teste de Tukey). Após o ensaio mecânip,p,fodos os corpos-de-prova foram analisados quanto ao tipo de fratura em Microscópio Estereoscópico (X25) e, os compósito/dentina foram selecionados 90 dentes, distribuídos e tratados como descrito anteriormente, exceto que apenas um corte no sentido vestíbulo-lingual foi realizado, para posterior preparo para análise em MEV. As fotomicrografias foram analisadas segundo os escores: O - ausência de camada híbrida e prolongamentos resinosos; 1 - ausência de camada híbrida e presença de prolongamentos resinosos; 2 - presença de camada híbrida e ausência de prolongamentos resinosos, e 3 - presença de camada híbrida e prolongamentos resinosos. Os dados obtidos foram submetidos à análise estatística (Teste de Kruskal-Wallis). De acordo com os resultados pôde-se concluir que: 1 - A diminuição no tempo de condicionamento ácido (7s) não interferiu nos valores de resistência da união compósito/dentina, para todos os sistemas de união utilizados neste estudo; 2 - Houve correlação negativa, apenas, entre a interação P&B2.1*tempo de condicionamento; 3 - A análise do padrão de fratura demonstrou maior predominância de falhas mistas para todos os grupos, exceto P&B 2.1, cujas falhas encontradas para os tempos de 7 e 15s foram adesivas e para o tempo de 20s coesiva em compósito; 4 - Quanto ao aspecto morfológico da união compósito/dentina pôde-se observar que a formação de camada híbrida e prolongamentos resinosos mostrou relação direta com o sistema de união utilizado / Abstract: The aim of this study was to evaluate the micro-tensile bond strength, the failure sites obtained after the test, and the resin/dentin interface, in different etching times (7, 15, and 20s) and with different bond systems (Single Bond-SB; Prime & Bond 2.1- P&B2.1; One Up Bond F-OUP e Clearfil SE Bond-CSE). 138 sound extracted primary teeth were selected. For the micro-tensile bond strength, 48 teeth were selected and randomly distributed into 3 groups, according to etching time, and subdivided into 4 subgroups, according to bond systems as follows (n=20): G1- 7s + SB; G2- 15s + SB; G3- 20s + SB; G4- 7s + P&B2.1; G5- 15s + P&B2.1; G6- 20s + P&B2.1; G7- 7s + OUP; G8- 15s + OUP; G9- 20s + OUP; G1Q- 7s + CSE; Gll- 15s + CSE; G12- 20s + CSE. The teeth were obliquely cut on the occlusal surface and flatenned until dentin area was reached. The bonding procedures were carried out according to groups, and the restorative procedure was carried out using the resin composite Filtek Z250. Next, the samples were sectioned in buccal-lingual and mesio-distal orientations, to obtain samples of about lmm2. The samples were stored in distilled water at 3-rC for 24h, and then submitted to micro-tensile bond strength in a Universal Testing Machine (Instron) with a crosshead speed of 0.5mm/min. The data were submitted to ANOV A and Tukey's test (p<0.05). The failure sites obtained after the test were observed, for failure type, in stereoscope microscopy of 25X magnification, and the representative failures of each group were observed in Scanning Electron Microscopy (SEM). 90 teeth were selected for the analysis of resin composite/dentin. The teeth were distributed and treated as previously described, except that just one. The photomicrographs were analyzed according to scores: o - absence of hybrid layer and resin tags; 1- absence of hybrid layer and presence of resin tags; 2 - presence of hybrid layer present and absence of resin tags, and 3 -presence of hybrid layer and resin tags. The data obtained were submitted to Kruskal-Wallis's testo According to the results it could be concluded that: 1 -the decrease in etching time (7s) did not interfere in bond values, for ali bond systems used; 2- there was negative correlation, solely, between P&B2.1*etching time interaction; 3 - the pattern of failure analysis showed major predominance of mixed failures for ali groups tested, except P&B 2.1, where failures for 7 and 15s were adhesives and for the 20s were composite cohesive; 4 - the resin composite/dentin area showed that the formation of hybrid layer and resin tags showed direct relation with the bond system used. / Mestrado / Materiais Dentarios / Mestre em Ciências
64

Avaliações 'in vitro' dos efeitos produzidos por agentes clareadores contendo peroxido de carbamida

Cavalli, Vanessa, 1977- 27 February 2003 (has links)
Orientador : Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T14:28:59Z (GMT). No. of bitstreams: 1 Cavalli_Vanessa_M.pdf: 3427869 bytes, checksum: 0a7fc94176769fa8298b0cff32a42ec8 (MD5) Previous issue date: 2003 / Resumo: A valorização e os beneficios proporcionados pelos procedimentos estéticos não invasivos, tomaram o clareamento dental com a utilização do peróxido de carbamida, o tratamento estético comumente realizado em pacientes. O destaque obtido por sua eficiência, simplicidade e segurança, potencializaram a comercialização de diferentes concentrações do agente oxidante, disponíveis tanto para a realização da técnica caseira ou noturna, ou em consultório, sob supervisão direta profissional. Entretanto, dúvidas surgiram a respeito de possíveis efeitos adversos provocados pelo peróxido de carbamida na superficie dental e suas conseqüências. Portanto, essa tese teve como objetivos: 1) analisar a micromorfologia superficial do esmalte após a utilização de peróxido de carbamida em baixa_ concentrações; 2) avaliar os efeitos de diferentes concentrações de peróxido de carbamida na rugosidade superficial do esmalte humano e examinar as alterações morfológicas da superficie clareada; 3) observar a ação de géis de alta concentração de peróxido de carbamida na rugosidade superficial e susceptibilidade à pigmentação do esmalte humano; 4) investigar os efeitos das concentrações 10%, 15%, 16% e 20% de peróxido de carbamida na resistência à tração do esmalte clareado e suas características morfológicas e 5) quantificar a resistência de união de um compósito resinoso na superficie do esmalte tratado com diferentes concentrações de peróxido de carbamida, 24 horas, 1, 2 e 3 semanas após o clareamento. Baseado nas metodologias experimentais adotadas, concluiu-se que o esmalte humano submetido ao tratamento clareador com peróxido de carbamida apresenta alteração micromorfológica superficial, e a severidade das modificações é proporcional à concentração do gel. Quando a superficie do esmalte foi submetida a maiores concentrações do gel clareador, houve aumento da rugosidade e maior susceptibilidade à pigmentação. A resistência à tração do esmalte clareado foi menor que a do substrato não tratado, e a resistência de união do compósito resinoso foi significantemente diminuída na superfície desse, quando clareado com peróxido de carbamida em concentrações de 10% a 20%. Entretanto, os valores de união foram semelhantes àqueles do esmalte não clareado, quando o procedimento adesivo foi realizado 21 dias após o clareamento / Abstract: The regards and benefits produced by non-invasive esthetic procedures, brought carbamide peroxide dental bleaching in a commonly esthetic treatment carried out on patients. The appeal based on its efficiency, simplicity and safety, has increased the commercialization of different concentrations of the oxidyzing agent, available either for at-home bleaching techniques, or for in-office bleaching procedures, under diret professional supervisiono However, uncertainties conceming possible side effects promoted by carbamide peroxide on enamel surface and their consequences have been raised. Therefore, the aim of this thesis were to: 1) analyze human enamel superficial micromorphology after the application of low concentrations of carbamide peroxide; 2) evaluate the effects of different concentrations of carbamide peroxide on human enamel surface roughness and examine the morphological alterations of the bleached surface; 3) observe the action of high concentrated carbamide peroxide gels on surface roughness and staining susceptibility of human enamel; 4) investigate the effects of 10%, 15%, 16% and 20% carbamide peroxide concentrations on the ultimate tensile strength of bleached enamel and surface morphological characteristics and 5) evaluate the bond strength of composite resin to enamel treated with different carbamide peroxide concentrations, 24 hours, 1, 2 and 3 weeks after bleaching. Based on the adopted experimental methodologies, it was concluded that human enamel submitted to carbamide peroxide treatment presented altered surface morphology, and the severity of the modifications were proportional to gel concentration. Enamel surface presented increased roughness and elevated staining susceptibility when submitted to high-concentrated bleaching solutions. The ultimate. tensile strength of bleached enamel was lower than the untreated substrate and the bond strength of composite resin was significantly reduced on the enamel surface when enamel surface was treated with 10% to 20% carbamide peroxide. Nevertheless, bond strengths reached values similar to untreated enamel, when the adhesive procedure was perfonned 21 days after bleaching / Mestrado / Dentística / Mestre em Clínica Odontológica
65

Analise quimica e topografica da superficie de implantes de titanio comercialmente puro atraves de espectroscopia de fotoeletrons excitada por raios-X (XPS) e microscopia eletronica de varredura (MEV)

Sardinha, Sandra de Cassia Santana 08 January 2003 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:59:55Z (GMT). No. of bitstreams: 1 Sardinha_SandradeCassiaSantana_D.pdf: 6778496 bytes, checksum: 6e85b28fae3ec96602b176bd2bbce76d (MD5) Previous issue date: 2003 / Resumo: Este trabalho teve como objetivo analisar, química e topograficamente, a superfície de implantes de titânio comercialmente puro, utilizados atualmente na Odontologia. Foram selecionados oito implantes das seguintes marcas comerciais: Conexão - Sistema de Próteses; Lifecore - Biomedical; AS Technology e S - Serson Internacional. As amostras apresentavam tratamento de superfície, através das técnicas de ataque ácido (Conexão) e plasma sprayde titânio (Lifecore-Biomedical; AS Technology e S - Serson International), sendo divididas em quatro grupos, contendo dois implantes do mesmo lote de cada fabricante. As análises foram realizadas através de Espectroscopia de Fotoelétrons Excitada por Raios-X (XPS) e Microscopia Eletrônica de Varredura (MEV). Os resultados da análise química mostraram os elementos titânio (Ti), oxigênio (O), silício (Si), zinco (Zn), alumínio (AI) e carbono (C). O estudo através do MEV revelou a topografia rugosa da superfície e uniformidade entre as roscas dos implantes. Pode-se concluir, deste modo, que houve impurezas na superfície dos implantes, que todas as amostras apresentaram rugosidade de superfície, mas que há necessidade de outros trabalhos que relacionem a presença desses compostos e sua interferência na osseointegração / Abstract: The aim of this study was to analyze the chemical and topography of the surface of currently utilized implants of commercially pure titanium. A total of eight implants were studied (Conexão - Sistema de Próteses, Lifecore Biomedical, AS Technology, and S - Serson International). Ali samples had treatment of surface. The samples were divided into four groups, containing two implants from the same lot of each manufacturer. The analysis of the samples was performed utilizing spectroscopy and electromicroscopy. Results showed predominance of the elements of titanium, oxygen, zinc, aluminum, silicon, and carbon in ali samples studied. The electromicroscopy showed the rough topography of the surface and uniformity between the implants. In conclusion, there were impurities in the surface of the implants. However, further studies are required to investigate the relationship between these chemical components in the surface of implants and their influence in the process of bony integration / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
66

Avaliação da alteração dimensional, resistencia ao impacto e morfologia de fratura da resina acrilica para microondas polimerizada em ciclo alternativo

Faot, Fernanda 23 March 2004 (has links)
Orientador: Renata Cunha Matheus Rodrigues Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T23:50:31Z (GMT). No. of bitstreams: 1 Faot_Fernanda_M.pdf: 6708746 bytes, checksum: 4a7e71f63273a71d6f27c36a33d30baa (MD5) Previous issue date: 2004 / Mestrado / Protese Dental / Mestre em Clínica Odontológica
67

Preparação e caracterização de compositos de celulose e oxido de antimonio

Toledo, Eduardo Aparecido 25 July 2018 (has links)
Orientador: Yoshitaka Gushikem / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-25T13:41:56Z (GMT). No. of bitstreams: 1 Toledo_EduardoAparecido_D.pdf: 2174447 bytes, checksum: 68f3a1bc3ddab00cb6e4b3de1cbb2da5 (MD5) Previous issue date: 1998 / Resumo: Neste trabalho foi desenvolvida uma metodologia para a preparação de compósitos de matrizes celulósicas ( a-celulose e acetato de celulose) com óxidos de antimônio (llI) e (V). Este método consiste na inserção de um precursor do óxido que submetido à hidrólise fornece o óxido desejado. Este método mostrou-se reprodutível e os compósitos formados apresentaram-se estáveis. Observou-se que a presença destes óxidos nas matrizescelulósicas altera suas propriedades físicas e químicas. No caso do compósito a-celulose/Sb2O3 observou-se que podem ser formadas duas distintas fases cristalinas, cúbica ou ortorrômbica, dependendo do método de hidrólise do precursor do óxido. Para os compósitos a-celulose/Sb2O5 mostrou-se que há presença apenas do antimônio (V) na matriz, o que permitiu sua transformação em FeSbO4. Esta fase de antimonato de ferro foi caracterizada por XPS e espectroscopia Mössbauer / Abstract: This work describes a methodology for the preparation of composites among cellulosic matrix ( a.-cellulose and cellulose acetate) with antimony (III) and (V) oxides. This method is based upon the insertion of a precursor in the matrix which is hydrolysed to oxide form. This method was reproductible and the composites formed were stable. The presence ot these oxides in the matrix changed their physical and chemical properties. For a-celulose/Sb2O3 composite it was observed the formation of two different crystalline structures, cubic and orthorombic, depending on employed hydrolysis method. For a-celulose/Sb2O5 composites it was detected the unique presence of antimony (V) which permited the formation of FeSbO4 phase. This antimonate phase was characterized by XPS and Mössbauer spectroscopy / Doutorado / Quimica Inorganica / Doutor em Ciências
68

Caracterização de compositos altamente energeticos por analise termica

Pinheiro, Glaci Ferreira Martins 24 April 1999 (has links)
Orientadores: Lucia Helena Innocentini Mei, Vera Lucia Lourenço / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-25T14:50:45Z (GMT). No. of bitstreams: 1 Pinheiro_GlaciFerreiraMartins_M.pdf: 3644774 bytes, checksum: ff7ec1bdc65ea452359f4df2c68b9271 (MD5) Previous issue date: 1999 / Resumo: Compósito altamente energéticos preparados com as nitraminas cíclicas HMX e RDX e ligante poliuretânico foram caracterizados por DMA, TMA, DSC, MEV. Verificou-se o efeito da granulometria, tipo e teor de carga, agente de cura e escala de processo nas propriedades termomecânicas e na decomposição dos compósitos. O DMA demonstrou alta sensibilidade para avaliar pequenas variações na formulação sendo o mais indicado para avaliar a temperatura de tansição vítrea. Pelo TMA foi avaliado o coeficiente de expansão térmica linear e pelo DSC a decomposição térmica dos compósitos. A análise microscópica permitiu relacionar resultados, obtidos através das diversas técnicas, com a morfologia dos compósitos. As melhores condições de processabilidade foram obtidas com mistura bimodal e distribuição de diâmetros mais aberta em cada faixa. Pequenas variações na distribuição granulométrica das cargas se refletiram nas propriedades finais dos compósitos e demonstraram ser influenciadas pelas características da carga. Observou-se que o ligante tem influência significativa no processo de decomposição das nitraminas. Os resultados obtidos mostraram que técnicas de análise térmica e de microscopia eletrônica de varredura são apropriadas para o estudo de composições energéticas devido a pequena quantidade necessária de amostra e rapidez dos ensaios, associada a grande sensibilidade dos equipamentos... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Highly energetic composites containing the cyclic nitramines HMX and RDX dispersed in a polyurethane matrix were prepared and characterized by DMA, TMA, DSC and SEM. It was evaluated the effects of type, particle size and content of the fillers, as well as the curing agent and batch size on the thermomechanical properties and decomposition process of the composites. DMA analyses showed to be very sensitive to evaluate small variations in the formulation, so it was used to determine the glass transition temperature of the compositions. The thermal expansion coefficient was obtained by TMA and the thermal decomposition by DSC. The microscopic analysis allowed to correlate results obtained through the several techniques with the morphology of the composites. The best processing conditions were obtained with bimodal mistures containing a wider particle size distribution in each range. Small variations in the particle size distribution of the fillers were reflected in the final properties of the composites. The thermomechanical properties presented good repetivity for all the composites and showed to be affected by the characteristics of the fillers. It was observed that the binder has a significant influence in the decomposition process of the nitramines. The obtained results showed that the thermal analysis and the scanning eletronic microscopic techniques are appropriate the study of energetic compositions due to the small amount of the samples required, high speed of the measuring associated to the sensitivity of the equipments... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Química
69

Avaliação da rugosidade radicular produzida por instrumentos sonicos, ultrasonicos, manuais e rotatorios : estudo "in vitro"

Martins, Eleonora de Oliveira Bandolin 22 November 1999 (has links)
Orientadores: Antonio Wilson Sallum, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T20:17:36Z (GMT). No. of bitstreams: 1 Martins_EleonoradeOliveiraBandolin_M.pdf: 7956484 bytes, checksum: f7f49506511d11e364f455a2fe8cf344 (MD5) Previous issue date: 1999 / Resumo: O objetivo deste trabalho é avaliar, in vitro, o grau de rugosidade radicular deixado pelos vários tipos de instrumentos utilizados durante o processo de instrumentação radicular. Foram selecionados 90 dentes unirradiculares, extraídos de pacientes que manifestaram periodontite avançada.. Em seguida, eles foram divididos aleatoriamente em 9 grupos experimentais (dez dentes por grupo), instrumentados com: grupo 1 - curetas Gracey; grupo 2 - aparelho sônico; grupo 3 - aparelho ultrasônico; grupo 4 - ponta diamantada extrafina, em caneta de alta-rotação; grupo 5 - ponta diamantada extrafina, em caneta de baixa-rotação; grupo 6 - broca carbide multilaminada de 12 lâminas, em caneta de alta-rotação; grupo 7 - broca carbide multilaminada de 12 lâminas, em caneta de baixa rotação; grupo 8 - broca carbide multilaminada de 30 lâminas, em caneta de alta-rotação; e, grupo 9 - broca carbide multilaminada de 30 lâminas, em caneta de baixa-rotação. Em seguida, foram confeccionadas amostras de cada raiz, as quais foram submetidas à análise rugosimétrica, obtendo-se a "porcentagem de redução de rugosidade por grupo" ( GR ). Estes dados foram submetidos à anális~ estatística. Foram também realizadas fotomicrografias em estereomicroscópio triocular e microscópio eletrônico de varredura para ilustrar a topografia da superficie radicular. Os resultados mostraram que as rugosidades foram diminuídas significantemente após a instrumentação em todos os grupos (45,16%). As brocas de 12 lâminas (67,75%) e a de 30 lâminas (65,02%) em alta-rotação mostraram valores maiores de porcentagem de redução de rugosidade e não diferiram estatisticamente entre si. Os grupos de ponta diamantada extra-fma em baixa-rotação (49,86%) e curetas (48,74%) não diferiram estatisticamente entre si, mas mostraram valores estatisticamente menores de porcentagem de ,redução de rugosidade em relação aos grupos seis e oito. Os grupos de diamantadas extra-fina em alta-rotação (40,90%) e 12 lâminas em baixa-rotação (39%) não diferiram estatisticamente entre si, mas mostraram valores estatisticamente menores de porcentagem de redução de rugosidade em relação ao grupos cinco e um. Os grupos de 30 lâminas em baixa-rotação (34,61%) e aparelho ultrasônico (33,33%) não diferiram estatisticamente entre si, mas mostraram valores estatisticamente menores porcentagem de redução de rugosidade radicular em relação aos grupos quatro e sete. O grupo de aparelho sônico (27,27%) mostrou o menor valor de porcentagem de redução de rugosidade, diferindo estatisticamente de todos os grupo / Abstract: The aim of this study was to evaluate in vitro the roughness degree generated for several instruments used for root planing. It were seleeted 90 teeth extracted from patients that had advaneed periodontal disease. Then, they were randomly divided into nine groups (ten teeth per group), sealed with several instruments: group 1: hand eurette; group 2: sonie sealer; group 3: ultrasonie sealer; group 4: fine grit diamond bur and high-speed handpieee; group 5: fine grit diamond bur and low-speed handpieee; group 6: 12 lamina bur and high-speed handpieee; group 7: 12 lamina bur and low-speed handpieee; group 8: 30 lamina bur and high-speed handpieee; group 9: 30 lamina bur and low-speed handpieee. After, it was made specimens from the roots that was taking step in the perfilometer, taking the "degree of roughness of the root" (Gr). It was take photomierographs in optieal mieroseopy and seanning eleetron mieroseopy to illustrate the roots surfaees. It was made a statistieal data analysis. The results showed that in alI groups the percent roughness deereased after instrumentation (45,16%). The 12 lamina (67,75%) and 30 lamina (65,02%) bur with high-speed showed the hig!1est values ofredueing ofroughness and didn't show signifieant differenee eaeh others. The fine grit diamond bur with 10w-speed handpieee (49,86%) and euretts (48,74%) groups didn't show signifieanee differenee eaeh other, but showed lower values than the six and eight groups. The fine grit diamond bur with high-speed handpieee(40,90%) and 12 lamina bur with low-speed handpieee (39%) didn't show differenee eaeh other, but showed values signifieant lower than the tive and one groups. The 30 lamina bur with low-speed handpieee (34,61 %) and ultrasonie (33,33%) didn't show signifieant differenee eaeh other, but showed signifieant lower values than the four and seven groups. The sonie sealer (27,27%) showed the signifieant lowest value of redueing of rougeess / Mestrado / Periodontia / Mestre em Clínica Odontológica
70

VARREDURA A LASER APLICADA NA RECONSTRUÇÃO 3D DE BENS MATERIAIS DO PATRIMÔNIO HISTÓRICO DE IGARASSU E OLINDA

ANDRADE, Henrique José Lins Ferreira de 14 September 2012 (has links)
Submitted by João Arthur Martins (joao.arthur@ufpe.br) on 2015-03-03T19:31:00Z No. of bitstreams: 2 Dissertacao_Versao_Definitiva_Henrique Jose Lins Ferreira de Andrade.pdf: 7026241 bytes, checksum: c852dc881bdb41715a053e5b7688ef44 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-03T19:31:00Z (GMT). No. of bitstreams: 2 Dissertacao_Versao_Definitiva_Henrique Jose Lins Ferreira de Andrade.pdf: 7026241 bytes, checksum: c852dc881bdb41715a053e5b7688ef44 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-09-14 / CAPES / Como determinadas formas arquitetônicas inseridas no espaço físico no presente, poderiam ser reconstruídas no futuro? A reconstrução tridimensional (3D) de determinado objeto permite sua melhor visualização e assimilação. Todavia, isso só se faz possível quando há precisão nas informações coletadas. Dentre as diversas técnicas existentes para obter estas informações, a varredura a laser mostra-se adequada para determinadas situações. O presente trabalho tem por objetivo mostrar as potencialidades da técnica de varredura a laser adequada ao levantamento de bens materiais do patrimônio histórico de Igarassu/PE e Olinda/PE. Inicialmente com os objetos de estudo definidos [Igreja e Recolhimento do Sagrado Coração de Jesus (Igarassu), Igreja dos Santos Cosme e Damião (Igarassu) e Igreja do Antigo Convento de Nossa Senhora do Carmo de Olinda (Olinda)], foram realizadas varreduras a laser em campo das fachadas principais destas igrejas e depois foi efetuado o processamento destes dados obtidos através de programas computacionais específicos. Os resultados obtidos através da varredura a laser, ou seja, reconstruções tridimensionais das fachadas dos objetos de estudo foram comparados com medições em campo e elevações das fachadas destas igrejas elaboradas por profissionais de Arquitetura. Com isso pode-se constatar algumas vantagens e desvantagens da técnica de varredura a laser para a documentação do patrimônio histórico. Portanto, este trabalho pode servir como base para área de projeto de preservação de sítios e monumentos históricos, devido à necessidade de se documentar os objetos de forma rápida e precisa

Page generated in 0.0505 seconds