41

Análise de técnicas compensatórias de drenagem urbana para atenuação de inundações em uma sub-bacia do rio Jiquiá no Recife

SILVA, Pedro Oliveira da 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T17:39:12Z (GMT). No. of bitstreams: 2 arquivo2468_1.pdf: 6859715 bytes, checksum: b60503e31284676127810a13aebd2c51 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Prefeitura da Cidade do Recife / Há milhares de anos quando do surgimento dos primeiros homens, a população tem apresentado uma taxa de crescimento era limitado até os primeiros anos da era cristã. Ocorre que a partir do inicio desta era, mais precisamente no inicio da idade média, a curva de crescimento populacional começa a apresentar um comportamento exponencial, e maior concentração nas cidades e consequentemente também maior contaminação dos mananciais. No Brasil a partir da década de 1960 as grandes cidades vêem apresentando uma urbanização acentuada que implica em altas taxas de impermeabilização do solo, e este processo vem influenciando diretamente os sistemas de drenagens de varias formas, sendo as inundações umas das principais conseqüências dos impactos causados pela impermeabilização, cujos níveis vêm ao longo dos anos se intensificando devido ao aumento das taxas de impermeabilização do solo, bem como também a ocupação desordenada principalmente das margens dos rios e canais. Neste sentido, o presente trabalho tem o objetivo de simular a partir do modelo hidrológico SWMM (Storm Water Management Model) desenvolvido pela EPA (Enviromental Protection Agency), a utilização de técnicas não convencionais de drenagem pluvial no ambiente urbano, denominadas técnicas compensatórias, que visam atenuar os níveis de inundações, provocadas por chuvas intensas. Para este procedimento foi estudada uma sub-bacia do canal da SANBRA localizado na zona oeste da cidade do Recife, que apresenta transbordamento do canal durante ocorrência de chuvas torrenciais causando inundação da via principal da localidade. Para tal foram elaborados trabalhos em campo para obter informações detalhadas desta sub-bacia, como topografia da área, no que se refere à altimetria, e cadastramento dos sistemas de micro e macro drenagens existentes. Além disso, a definição de parâmetros e variáveis da área de estudo, tais como: a área impermeável e permeável, a partir de análise no local e imagens de orto-fotos, e a taxa de infiltração dentre outros foram obtidas com vistas a alimentar o modelo hidrológico. Buscou-se simular técnicas independentes como reservatório em lotes, reservatórios em setores da sub-bacia ao longo da rede de micro drenagem (on line) e na sub-bacia ao longo do curso do canal aproveitando uma área remanescente para transformá-la numa bacia de detenção. Os resultados corroboraram com os apresentados em literaturas técnicas semelhantes, destacando a bacia de detenção na sub-bacia como a mais eficaz, reduzindo o pico de vazão a 55 % em média; a detenção em setores apresentou eficiência de 28,3 % em média na redução das vazões, já a detenção em lotes obteve melhor eficiência quando os microrreservatórios tem a função de retenção da água de chuva para uma utilização futura, chegando a reduzir as vazões de pico a 83 %. O presente trabalho teve também o objetivo de fornecer subsídios técnicos para o órgão gestor da drenagem urbana da cidade do Recife
42

Análise do comportamento da precipitação e da vazão em bacias hidrográficas Amazônicas

HACHEM, Bruno Penna 14 March 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:18:51Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseComportamentoPrecipitacao.pdf: 2405774 bytes, checksum: 7ea118e16acf671eb4f59ba203b8f810 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-17T14:07:08Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseComportamentoPrecipitacao.pdf: 2405774 bytes, checksum: 7ea118e16acf671eb4f59ba203b8f810 (MD5) / Made available in DSpace on 2017-03-17T14:07:08Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseComportamentoPrecipitacao.pdf: 2405774 bytes, checksum: 7ea118e16acf671eb4f59ba203b8f810 (MD5) Previous issue date: 2016-03-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo desse trabalho foi analisar o comportamento da precipitação e da vazão, em duas Regiões hidrográficas do estado do Pará, no caso Calha Norte e Costa Atlântico Nordeste. Ambas possuem o mesmo regime pluviométrico e as características físicas das bacias são semelhantes, sendo distintas apenas no que se refere ao nível de preservação vegetal e área. Para esse trabalho foram utilizadas 7 estações fluviométricas e 7 pluviométricas na Calha Norte e 6 fluviométricas e 6 pluviométricas na Costa Atlântico Nordeste. Após a coleta dos dados no Hidroweb, os mesmos foram organizados em planilhas do software Microsoft Excel para aplicação dos testes de Mann Kendall e Spearman, os quais afirmaram que não há tendência nas séries analisadas para α de 5%. Foi detectado que a densidade de estações fluviométricas e pluviométricas está baixa, segundo os limites mínimos estabelecidos pela OMM.. A correlação linear de Pearson apresentou-se “forte” entre a precipitação e vazão das áreas estudadas, as quais também sofrem influência dos fenômenos climáticos (El Niño e La Niña). Foi possível considerar que na Região mais preservada o tempo de defasagem entre o máximo da precipitação e o máximo da vazão foi em média de 2 meses, enquanto na região com uma ação antrópica maior esse tempo foi em média de 1 mês. / The aim of this study was to analyze the behavior of precipitation and flow in two river regions of the state of Pará, where Northern Corridor and Coast Northeast Atlantic. Both have the same rainfall and physical properties of the bowls are similar, being different only in regard to level and vegetable preservation area. For this study, we used 7 gauged stations and 7 rainfall in the Northern Corridor and 6 fluviometric 6 and rainfall in Costa Northeast Atlantic. After collecting the data in HIDROWEB, they were organized in Microsoft Excel spreadsheets software for application of Mann Kendall and Spearman tests, which stated that there is no trend in the series analyzed (α=5%). Was detected that the density of fluviometric and rainfall stations is low , according to the thresholds established by WMO. The Pearson correlation coefficients showed up "strong" between precipitation and flow of the areas studied, which also suffer influence of climatic phenomena (El Niño and La Niña). It was possible to consider that in the most preserved region, the time lag between the maximum rainfall and the maximum flow rate averaged two months, while the region with greater human action this time was an average of 1 month.
43

Integridade ambiental de corpos d’água: degradação ambiental, funções ecossistêmicas e perda de serviços ecossistêmicos no baixo São Francisco

Freire, Rafael Rodrigues 27 September 2012 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2013-12-18T13:09:01Z No. of bitstreams: 1 Dissertação Rafael Rodrigues Freire - MAASA - UFBA.pdf: 1905742 bytes, checksum: 8d1722916d61eda0f85c6e156ec2a8cf (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2013-12-18T13:09:13Z (GMT) No. of bitstreams: 1 Dissertação Rafael Rodrigues Freire - MAASA - UFBA.pdf: 1905742 bytes, checksum: 8d1722916d61eda0f85c6e156ec2a8cf (MD5) / Made available in DSpace on 2013-12-18T13:09:14Z (GMT). No. of bitstreams: 1 Dissertação Rafael Rodrigues Freire - MAASA - UFBA.pdf: 1905742 bytes, checksum: 8d1722916d61eda0f85c6e156ec2a8cf (MD5) / Os estudos de definição de hidrogramas ambientais, necessários para amenizar os impactos causados por barramentos, buscam alternativas para conciliar usos e sustentabilidade de recursos naturais, visando à conservação ambiental e a redução de conflitos de usuários. Um dos mecanismos para determinação da vazão ambiental é a metodologia Building Block que é baseada em um processo de interação entre cientistas e comunidades de usos tradicionais, e considera a população extrativista e ribeirinha como uma das fontes de informação para o conhecimento do rio, por estar em contato diário com ele e por depender diretamente do seu estado saudável e da diversidade de sua biota. Esta metodologia prevê, na sua fase inicial, a avaliação do estado da integridade do habitat, a fim de conhecer preliminarmente um retrato dos efeitos das alterações dos processos ambientais, informações que auxiliam na definição do planejamento dos estudos sucessivos e na individuação das localidades mais representativas, selecionadas como pontos amostrais da pesquisa. Contudo, a avaliação da Integridade do Habitat proposta no BBM leva em consideração exclusivamente aspectos ecológicos, mais especificamente de habitat, não considerando os aspectos socioambientais relacionados aos diversos usos de recursos naturais. Isso constitui uma contradição em relação aos objetivos intrínsecos ao conceito de vazão ambiental. Por esta razão, este trabalho teve como objetivo propor um aprimoramento da metodologia BBM, na sua fase inicial de planejamento dos estudos, agregando à ferramenta de definição da integridade do habitat um componente de avaliação socioambiental. Este componente socioambiental foi incorporado através da avaliação da perda de disponibilidade dos serviços ecossistêmicos percebida pelas comunidades extrativistas ribeirinhas. A partir dos relatos de informantes-chaves foram definidos oitos indicadores quali-quantitativos para individuar o estado de perda de recursos naturais e a perda de serviços e funções ecossistêmicas desempenhadas pelo rio. Esses resultados foram comparados com os dados da avaliação da integridade de habitat segundo metodologia BBM, chegando a conclusão de que os dois métodos de avaliação podem chegar a avaliações deferentes sobre o estado de degradação ambiental. Por esta razão é possível afirmar que a avaliação das perdas de funções e serviços ecossistêmicos proveniente da experiência das populações ribeirinhas constitui um conhecimento adicional sobre as complexidades físicas, químicas, biológicas e socioambientais, fundamentais para a decisão de escolha dos sites de amostragens para execução dos estudos da metodologia BBM e que, portanto, deveria ser incorporado à fase inicial de avaliação da Integridade do Habitat dessa metodologia. Para o desenvolvimento desta pesquisa foi escolhido o caso de estudo do baixo curso do rio São Francisco.
44

Vazões ambientais em hidrelétricas : Belo Monte e Manso

Souza, Christopher Freire January 2009 (has links)
Impactos sócio-ambientais negativos têm colocado a gestão do meio ambiente e dos recursos hídricos em cheque. Produção econômica intensiva, especialmente onde existem hidrelétricas, tem conduzido à perda de abundância e riqueza de espécies e conseqüente diminuição de produção de serviços ambientais à sociedade. Em contrapartida, avanços científicos em ecologia têm demonstrado que a conservação de regimes hidrológicos é o caminho para conservação de ecossistemas e para manutenção da produção de serviços ambientais. É neste contexto que cresce em importância a ferramenta de vazões ambientais, que tem como propósito compatibilizar interesses dos diferentes setores de produção, ao manter em corpos d’água regimes hidrológicos que produzam melhores resultados sócio-econômicos com menores impactos ambientais. O objetivo desta pesquisa é propor um método para a escolha de vazões ambientais, especialmente em regiões com escassez de informações ecológicas. O método proposto fundamenta-se na relação de influência direta entre conservação de regimes hidrológicos, conservação de ecossistemas e produção de serviços ambientais. Para isto, as alterações de regimes hidrológicos são quantificadas para qualificar o grau de conservação do ambiente e de produção econômica por serviços ambientais. O método consiste em diagnosticar alterações hidrológicas, elaborar potenciais regras de vazões ambientais, simular numericamente sua aplicação e prognosticar seus impactos via estudos de alteração hidrológica e de produção econômica por atividades antrópicas. A aplicação da metodologia foi dividida em dois estudos de casos. No primeiro, foram analisadas vazões ambientais para o projeto de aproveitamento hidrelétrico de Belo Monte, no rio Xingu, que ainda não sofre de alterações significativas do regime hidrológico. O segundo estudo consistiu do estudo do grau e da extensão de alteração do regime hidrológico pelo aproveitamento múltiplo da Usina de Manso, no rio Manso, afluente ao rio Cuiabá que drena ao Pantanal. Como resultado, o método mostrou ser flexível a diferentes configurações de disponibilidade de informação, além de possibilitar a escolha de vazões ambientais de forma transparente, colaborativa e participativa. A confiabilidade do método, no entanto, depende da representatividade das informações hidrológicas e do grau de incertezas quanto à relação entre alteração hidrológica, degradação de ecossistemas e perda de produção econômica, quando dados ecológicos são escassos. / The natural flow paradigm has not been considered in the Brazilian water resources and environmental management systems yet. Environmental flows studies have just been considered by Brazilian scientific community with too few, if any, experimental studies being undertaken. However, such a tool needs to be considered urgently, once environmental flows sustain ecosystem and their environmental services, which are of great importance to society. This thesis aims to propose a method to subsidize environmental flows selection, especially in regions where ecological data is scarce. We have based such method on the direct influential relation between flow regime alteration, ecosystem degradation and environmental services loss, applying hydrologic alteration indices as proxies of ecosystems degradation and environmental services loss. This new method consists on diagnosing hydrologic alteration, developing potential environmental flows rules, numerically simulate them and assessing theirs impacts on hydrologic alteration and economic production by human activities. The method application was split in two case studies in order to use different sets of its techniques. The former study consisted on assessing environmental flows downstream the projected UHE Belo Monte, located in the Xingu river, a tributary to the Amazon river. In this study only one flow station was applied with its “naturalized” flows as a benchmark. The latter study consisted on assessing the degree and extension of APM Manso dam hydrological impacts, located in a tributary to the Brazilian Pantanal. In this study, data from different stations where used as benchmarks. As a result, this hydrological method showed flexibility to work with different information settings, while it could be applied in a transparent, participative and collaborative approach. However, its confidence relies on hydrological data representativity and on the uncertainty over the relation between hydrological alteration, ecosystems degradation and loss of environmental services, when ecological data are scarce.
45

Desempenho de reatores biológicos aeróbios de leito fluidizado inverso na remoçao de carga orgânica

Zim, Graziela January 2006 (has links)
Este estudo avaliou a eficiência de reatores biológicos aeróbios de leito fluidizado inverso na remoção de matéria orgânica quando submetidos a diferentes condições operacionais (vazão de recirculação e carga orgânica aplicada). O experimento, em escala de laboratório, foi realizado em três reatores cilíndricos (R1, R2 e R3) com altura total de 2,00 m, diâmetro interno de 0,10 m e volume útil de 15,70 L. Como meio suporte para o desenvolvimento do biofilme foram utilizadas partículas de polipropileno (PP) em volume equivalente a 40% do volume útil do reator. O afluente entrava nos reatores pelo topo e saía pelo fundo e o oxigênio era fornecido através de um aerador poroso. Os reatores R1, R2 e R3 foram operados com vazão de recirculação de 2,50 L/min, 4,00 L/min e 5,50 L/min, respectivamente, durante todo período experimental. Os reatores foram alimentados com esgoto sintético caracteristicamente doméstico e o experimento consistiu de três etapas, conforme a carga orgânica aplicada: Etapa de Menor Carga – 0,70 Kg DQO/m3.dia; Etapa de Carga Intermediária – 1,70 Kg DQO/m3.dia e Etapa de Maior Carga – 3,90 Kg DQO/m3.dia. A vazão de alimentação foi mantida constante durante todo período experimental correspondendo ao TDH de 12 horas.O acompanhamento dos reatores foi realizado com medidas de DQO, sólidos livres (suspensão) e aderidos (biofilme). Foi determinada também a velocidade ascensional das biopartículas no meio líquido, tendo como motivo a identificação das possíveis causas da expansão excessiva ocorrida durante a realização do experimento. Os resultados obtidos demonstraram elevada eficiência de remoção carbonácea em termos de DQO, com médias superior a 93% na etapa de Carga Intermediária e em torno de 90% para a etapa de Maior Carga. Conforme avaliação estatística, não houve evidências de que a vazão de recirculação tenha efeito sobre a eficiência de remoção carbonácea. O aumento da carga orgânica afluente reduziu de forma significativa a eficiência de remoção carbonácea apenas no reator de menor vazão de recirculação. Em relação à quantidade de sólidos voláteis, o aumento da vazão de recirculação resultou em aumento dos sólidos voláteis aderidos, porém não foi identificado efeito sobre a quantidade de sólidos voláteis livres.O aumento de carga aplicada resultou em aumento significativo na quantidade média de sólidos voláteis livres nos reatores. Quanto aos sólidos voláteis aderidos, o acréscimo de carga afluente repercutiu de forma diferente nos três reatores: para a menor vazão de recirculação houve redução na massa de sólidos voláteis aderidos, para a vazão de recirculação intermediária ocorreu aumento da massa de sólidos voláteis aderidos e para a maior vazão de recirculação o aumento da carga aplicada não influenciou a quantidade de sólidos aderidos voláteis presentes no reator. A velocidade ascensional média das biopartículas diminuiu com o aumento da vazão de recirculação, significando que quanto maior a vazão de recirculação maior a densidade das biopartículas. / This study evaluated the efficiency of down flow aerobic fluidized bed reactors for the removal of organic mater submitted to different operational conditions (recirculation flow and applied organic load). The experiment was run on 3 cylindrical lab scale reactors (R1, R2 and R3) with 2 m total height, 0.10 m internal diameter and working volume of 15.70 L. Polypropylene particles were used as the support material for the development of the biofilm occupying 40% of the working volume of the reactors. The influent were applied at the top of the columns and withdraw from the bottom and the oxygen was supplied throughout a porous stone. The reactors R1, R2 and R3 were operated with recirculation flow of 2,50, 4.00 and 5.50 L. min-1, respectively, throughout the experimental work.The reactors were fed with synthetic wastewater similar to sanitary wastewater and the experiment was performed in 3 steps, according to the applied organic loading rate, namely: Lower Load - 0,70 Kg COD/m3.dia; Intermediate Load - 1,70 Kg COD/m3.dia; Higher Load - 3,90 Kg COD/m3.dia. The feeding flow was maintained constant throughout the experiment to obtain HDT equal to 12 hours. The reactors were monitored with conventional parameters such as COD, free suspended solids and attached suspended solids (biofilm). The upflow velocity of the bioparticles in the liquid phase was also determined with the purpose to identify the potential causes of the excessive expansion of the bed observed during the experimental work. The experimental results demonstrated high efficiency of carbonaceous COD removal, with average values above 93 % during the Intermediate Load step and around 90 % for the Higher Load. According to statistical evaluation, the recirculation flow did not provided significant effect upon the carbonaceous organic matter removal. The increase in applied organic load caused a significant decrease only to the reactor operated with the lower recirculation flow. Regarding the amount of volatile solids, the increase of the recirculation flow resulted in the increase of the attached volatile solids, however it was not identified any effect upon the amount of free volatile solids. The increase of applied organic load resulted in significant increase of the amount of the free volatile solids in the reactors. Regarding the attached volatile solids, the increase of applied organic load resulted in misleading behavior of the reactors, as follows: the lower recirculation flow resulted in a reduction of the amount of attached volatile solids; the intermediate recirculation flow resulted in an increase of the attached volatile solids, while it was not observed any significant variation in the amount of attached volatile solids inside the reactor operated with the higher recirculation flow. The average accession velocity of the bioparticles decreased with the increase of the recirculation flow, implying that the recirculation flow resulted in higher values of the bioparticles density.
46

Análise comparativa de incertezas em métodos para estimação de freqüências de vazões máximas diárias com incorporação de variação climática em bacias do medio rio Uruguai

Failache Gallo, Nicolás January 2007 (has links)
O presente trabalho apresenta metodologias para aprimorar a estimativa de freqüências de vazões diárias máximas extremas na bacia de rio Quaraí e de 13 bacias do médio rio Uruguai, no Brasil e Uruguai. Inicialmente foram ajustados, para os dados de cada bacia, e utilizando máxima verossimilhança, os parâmetros da distribuição GEV e seu caso particular Gumbel. Utilizando a função de Deviança foi testada em cada caso, com um nível de significância de 95%, a conveniência de utilizar o modelo GEV (3 parâmetros) em lugar do modelo Gumbel (2 parâmetros). Também foram analisados os valores e as incertezas de vazões de 25, 50 e 100 anos de período de retorno calculados com as duas distribuições. O resultado obtido foi que é satisfatório utilizar o modelo de Gumbel. Posteriormente, foi proposto um novo modelo a partir da distribuição de Gumbel. Este modelo supõe uma dependência linear do parâmetro de posição μ com as temperaturas de superfície do oceano SST (μ(t)=a+b.SST(t)). Novamente os parâmetros a, b e σ foram estimados mediante máxima verossimilhança. Foram utilizados os dados de reconstrução das SST dos oceanos disponíveis desde o ano 1854 para todo o planeta em células de 2 graus. Para cada célula de temperaturas de superfície do oceano Pacífico foi testada, para cada bacia, utilizando a função de Deviança, a significância de supor b≠0. A região compreendida entre os 14ºN, 12ºS, 79ºO e 149ºO, é a que apresenta maior significância de que o modelo proposto (supondo b≠0) consiga um melhor ajuste dos dados. O seja a probabilidade calculada de ocorrer as vazões observadas é maior se são consideradas as SST, além disso, pode se dizer que o teste efetuado indica que é maior o ganho de incorporar as SST do que agregar um novo parâmetro ao modelo. Em 12 bacias o modelo ajustado prevê que com o aumento da SST os períodos de retorno de vazões extremas diminuem, resultado coerente com o obtido por diversos autores para as precipitações e vazões médias e extremas em escala de tempo mensal ou anual. No trabalho foram analisadas três técnicas para determinar os intervalos de confiança dos parâmetros e as vazões ajustadas: a técnica que utiliza a curvatura do logaritmo da função de máxima verossimilhança e duas técnicas de bootstrap. As técnicas de bootstrap foram implementadas para determinar intervalos de confiança nos parâmetros ou diretamente nas vazões. As duas técnicas resultaram similares, mas no modelo proposto com as SST os intervalos de confiança somente puderam ser obtidos a partir da técnica de bootstrap diretamente nas vazões. / This work presents methods for improving estimates of the frequency of occurrence of extreme values of annual daily flows in the basin of the R. Quaraí and 13 other basins in the middle of the R. Uruguai catchment. For each basin, the three parameters of the Generalized Extreme Value (GEV) distribution were estimated by maximum likehood, together with the two parameters of the Gumbel distribution, a special case of the GEV distribution. Using the Deviança function, the hypothesis that the Gumbel distribution (2 parameters) gave an adequate fit to the distribution was tested against the alternative GEV (3 parameters), using a 5% significance level. Values of annual maxima with return periods 25, 50 and 100 years, and their errors, were then analyzed for the two distributions. Results showed that the Gumbel distribution fitted adequately. A new model was then tested using the Gumbel distribution, in which the position parameter was a linear function of sea surface temperature SST (μ(t)=a+b.SST(t)). The parameters a, b and the dispersion parameter σ were again estimated by maximum likelihood. The reconstructed series of global SST extending back to 1854 was used with a grid size of 2 degrees. For each cell in the Atlantic Ocean, a Deviança function was calculated and the hypothesis b=0 was tested for each basin. The ocean region showing strongest evidence against the hypothesis b=0 lay between 14ºN, 12ºS, 79ºW and 149ºW, showing that the fit of the Gumbel distribution to the observed annual maxima is better when they are related to SST, so that is then preferable to use the Gumbel with SSTs than to use the extra parameter of the GEV distribution. In 12 basins the fitted model showed that as SST increases, the return period of extreme flows decreases. This agrees with results obtained by other authors for rainfall and mean and extreme flows at the monthly and annual time scales. Three methods were compared for evaluating confidence intervals for model parameters and fitted flows: these were a method using curvature of the log-likehood function, and two bootstrap methods. The bootstrap methods were used to determine the confidence intervals of parameters or of flows directly. The two methods gave similar results, but in the model which includes SST, confidence intervals could only be calculated by the bootstrap method directly for flows.
47

Operação do conjunto bomba centrífuga, motor de indução trifásico e conversor de freqüência visando a eficiência no uso da energia elétrica / Operation set centrifugal pump, three-phase induction motor and frequency converter aimed at efficient use of electricity

Schmidlin Júnior, Celso Rogério 03 November 2006 (has links)
SCHMIDLIN JÚNIOR, C. R. Operação do conjunto bomba centrífuga, motor de indução trifásico e conversor de freqüência visando a eficiência no uso da energia elétrica. 2006. 119 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2006. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-06-08T14:38:00Z No. of bitstreams: 1 2006_dis_crschmidlinjúnior.pdf: 1842220 bytes, checksum: 6a20ad6bd1195abf59a5536f6c9d4c0c (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-20T18:52:42Z (GMT) No. of bitstreams: 1 2006_dis_crschmidlinjúnior.pdf: 1842220 bytes, checksum: 6a20ad6bd1195abf59a5536f6c9d4c0c (MD5) / Made available in DSpace on 2016-07-20T18:52:42Z (GMT). No. of bitstreams: 1 2006_dis_crschmidlinjúnior.pdf: 1842220 bytes, checksum: 6a20ad6bd1195abf59a5536f6c9d4c0c (MD5) Previous issue date: 2006-11-03 / This work aims to experimentally quantify, in LAMOTRIZ, the reduction of the active power required by the drive of a centrifugal pump that opts for the operation according to the outflow reduction method by speed variation instead the one that uses strangulation valve. Moreover, aims to develop a mathematical model that is capable to previously determine the consumption of electric energy of a pumping system that operates according to any one of these two methods of outflow reduction. / Este trabalho visa, por meio de ensaios realizados no LAMOTRIZ, quantificar a redução da potência ativa requerida pelo elemento acionador de uma bomba centrífuga que opta pela operação segundo o método de redução de vazão via variação de velocidade ao invés do que usa válvula de estrangulamento. Ainda, objetiva desenvolver um modelo matemático que seja capaz de determinar previamente o consumo de energia elétrica de um sistema de bombeamento que opere segundo qualquer um desses dois métodos de redução de vazão.
48

Caracterização hidrogeológica de bacias hidrográficas do semiárido baiano através de técnicas de geoprocessamento / Hydrogeological characterization of watersheds in the semi arid baiano using GIS techniques

Silva, Edivam José da January 2009 (has links)
SILVA, Edivam José da. Caracterização hidrogeológica de bacias hidrográficas do semiárido baiano através de técnicas de geoprocessamento. 2009. 154 f. Dissertação (Mestrado em engenharia agrícola)- Universidade Federal do Ceará, Fortaleza-CE, 2009. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-17T18:15:02Z No. of bitstreams: 1 2009_dis_ejsilva.pdf: 5998431 bytes, checksum: c32a63b48bb499629a3c3ad3b9d04e47 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-07-21T20:09:43Z (GMT) No. of bitstreams: 1 2009_dis_ejsilva.pdf: 5998431 bytes, checksum: c32a63b48bb499629a3c3ad3b9d04e47 (MD5) / Made available in DSpace on 2016-07-21T20:09:43Z (GMT). No. of bitstreams: 1 2009_dis_ejsilva.pdf: 5998431 bytes, checksum: c32a63b48bb499629a3c3ad3b9d04e47 (MD5) Previous issue date: 2009 / For the adoption of water resources management in dry regions where water availability is limited, knowledge of the different processes of the hydrological cycle is needed, especially the precipitation and flow. Therefore, techniques of GIS are essential in studies of hydrological modeling. The study on maximum flow in a watershed is important because the same act on soil erosion, flooding in urban and rural areas, hydraulic works, among others. The Salitre basin is located in the State of Bahia, Brazil, and its Pacui sub-basin is fully inserted in the Campo Formoso municipio. With a drainage area of 987.74 km2, it is one of the main drainage sub-basin of Salitre river. Hence, the objective of this work was to characterize physiographically the Pacui sub-basin, estimate peak flow by USDA-SCS and Dooge methods, and estimate the hourly evapotranspiration in the sub-basin using the algorithm SEBAL (Surface Energy Balance Algorithms for Land) and images from Landsat 7 - ETM. The Global Mapper software was used for the analysis of land numerical model (SRTM). The ENVI 4.3 software was used for georeferencing of data from topographic maps of SUDENE, and the Arcmap 9.2 software was used for watershed delineation. The time of concentration was determined by USDA and Dooge methods. To determine the radiation balance images from the INPE (National Institute for Space Research) were used and processed by Arcmap ® software, within algorithm SEBAL was developed. The basin presented low slope and then tends to reduce the flood peak because of the low speed runoff. ArcHidro proved to be an effective tool in the delineation of river basins and the generation of drainage network and compared with those obtained by maps from SUDENE. The algorithm SEBAL proved to be an agile and efficient tool in evapotranspiration estimation. The use of SRTM provided information of parameters as surface albedo, incident long-wave and shortwave radiations, pixel to pixel. Lower rates of hourly evapotranspiration (<0.15 mm.h-1) were recorded in areas of exposed soils, and higher rates were found in irrigated areas and vegetation, expressing the sensitivity of algorithm SEBAL on evapotranspiration estimation in watershed scale. / Para a adoção de uma gestão adequada dos recursos hídricos tendo como unidade de planejamento a bacia hidrográfica, o conhecimento dos diferentes processos do ciclo hidrológico se faz necessário, notadamente da precipitação, do escoamento e da evapotranspiração. Portanto, técnicas de geoprocessamento são imprescindíveis nos estudos de modelagem hidrológica a nível de bacias hidrográficas. O estudo sobre o escoamento superficial, em uma bacia hidrográfica é importante pelo fato do mesmo atuar sobre a erosão do solo, inundações em áreas rurais e urbanas, obras hidráulicas, entre outros. A bacia do rio Salitre esta localizada no Estado da Bahia, e a sub-bacia do rio Pacui esta inserida totalmente no município de Campo Formoso, com área de drenagem de 987,74 km2, constituindo umas das principais subbacias de drenagem para o rio Salitre. Nesse contexto, objetivou-se caracterizar fisiograficamente a sub-bacia rio Pacui e bacia do rio Salitre, analisar a estimativa de vazão de pico pelos métodos de SCS-USDA e de Dooge, e estimar a evapotranspiração horária na bacia do rio Pacui utilizando-se o algoritmo SEBAL (Surface Energy Balance Algorithms for Land) e imagens do Landsat 7 – ETM. Utilizou-se os softwares Global Mapper, para análises do modelo numérico do terreno (SRTM), ENVI 4.3, para georeferenciamento dos dados tendo como base as cartas topográficas da SUDENE e do software ArcMap 9.2 para delimitação automática de bacias. O tempo de concentração foi determinado pelos métodos USDA e de Dooge. Para determinar o balanço de radiação utilizou-se de imagem da região obtida junto ao INPE (Instituto Nacional de Pesquisas Espaciais) e processadas na ferramenta álgebra de mapa no software ArcMap® onde foi desenvolvido o algoritmo SEBAL. A bacia apresenta baixa declividade, portanto tende a uma redução dos picos de descargas devido à baixa velocidade de escoamento superficial. A extensão ArcHidro mostrou-se uma ferramenta eficaz na delimitação de bacias e na geração de rede drenagem, comparando com as obtidas pelas cartas da DSG/SUDENE. O algoritmo SEBAL mostrou-se uma ferramenta ágil e eficiente na estimativa da evapotranspiração. A utilização do SRTM proporcionou ganhos de informações nos parâmetros albedo da superfície, radiação de ondas longas incidente, radiação de onda curtas incidente, pixel a pixel. Menores taxas de evapotranspiração horária (< 0,15 mm.h-1) foram registradas em áreas de solos expostos e as maiores nas áreas irrigadas e vegetação no geral, expressando a sensibilidade do algoritmo SEBAL na estimativa da evapotranspiração em escala de bacias hidrográficas.
49

Vulnerabilidade de reservatórios em rios de alta variabilidade em um cenário de mudanças climáticas / Vulnerability of resevoirs in rivers of high variability in a scene of climate change

Cysne, Andréa Pereira 27 July 2007 (has links)
CYSNE, A. P. Vulnerabilidade de reservatórios em rios de alta variabilidade em um cenário de mudanças climáticas. 2007. 93 f. Dissertação (Mestrado em Engenharia Civil: Recursos Hídricos) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2007. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-04-19T19:40:57Z No. of bitstreams: 1 2007_dis_apcysne.pdf: 713205 bytes, checksum: bcefc0688187046bb0193d7de19bf4bd (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-04-22T14:29:59Z (GMT) No. of bitstreams: 1 2007_dis_apcysne.pdf: 713205 bytes, checksum: bcefc0688187046bb0193d7de19bf4bd (MD5) / Made available in DSpace on 2016-04-22T14:29:59Z (GMT). No. of bitstreams: 1 2007_dis_apcysne.pdf: 713205 bytes, checksum: bcefc0688187046bb0193d7de19bf4bd (MD5) Previous issue date: 2007-07-27 / It is much talked nowadays about the possible climatic changes as a result of the gas emission on the atmosphere. Although it is not a common agreement, a great part of the scientific community believe that an elevation of the measured global temperature will occur, which can provoke, for example, a medium increase on the ocean levels. Associated to this, there is also a consensus that significant transformations will happen on the pluvial and evaporation regimen around the world. However, the quantification of these changes, on specific locations, is still needed more studies, which can allow more conclusive evaluations about the theme. With that been said, this study tried to put some light on this theme, and considering some scenarios of alteration on the precipitation patterns and evaporation (considering liquid evaporation = E-P) it was evaluated the impact of these climatic changes in reservoirs yield at Northeast Semi-Arid of Brazil. whose rivers present high coefficient of variation of the annual emanations. It was observed that in rivers less variable – CV equal to 0,6 and 0,8 – it is necessary that the net evaporation EL increase 60% so that the reservoir can lose about 10% of its regularized outflow. But for rivers with high variability – CV equal to 1,4 and 1,6 – the net evaporation – would need a increase of just 30% so that the reservoir could be the object of the same reduction. It was concluded that, as most of the half-barren northeast’s reservoirs are located on rivers that present variation coefficients of the annual emanations in lathe of 1,2 to 1,6 , a greater attention should be given to these, since it showed sensible enough to the climatic variations. / Fala-se hoje muito sobre as possíveis mudanças climáticas como resultado das emissões de gases na atmosfera. Embora não seja de comum acordo, grande parte da comunidade científica acredita que acontecerá uma elevação na temperatura média global, o qual pode provocar, por exemplo, um aumento médio nos níveis dos oceanos. Associada a isto, há também um consenso de que haverá significativas transformações no regime pluvial e de evaporação em várias partes do planeta. Entretanto, a quantificação dessas mudanças, em locais específicos, ainda necessitam de mais estudos, os quais permitirão avaliações mais conclusivas a respeito do tema. Sendo assim, o presente trabalho procurou jogar um pouco de luz neste tema e, considerando alguns cenários de alteração nos padrões de precipitação e evaporação (considerando a evaporação líquida = E-P), avaliou os impactos destas mudanças climáticas na vazão regularizada de reservatórios no Nordeste semi-árido, cujos rios apresentam altos coeficiente de variação dos deflúvios anuais. Observou-se que em rios menos variáveis – CV iguais a 0,6 e 0,8 – é necessário que a lâmina líquida (EL) aumente 60% para que o reservatório perca cerca de 10% de sua vazão regularizada. Já para rios de maior variabilidade - CV iguais a 1,4 e 1,6 – a lâmina líquida precisaria de um aumento de apenas 30%, para que o reservatório fosse objeto desta mesma redução. Concluiu-se, portanto, que como a maioria dos reservatórios do Nordeste semi-árido localiza-se em rios que apresentam coeficientes de variação dos deflúvios anuais em torno de 1,2 a 1,6, uma atenção maior deverá ser dada aos mesmos, uma vez que se mostraram bastante sensíveis as variações climáticas.
50

Análise Comparativa da Medição de Vazão em Flare Por Tecnologia Ótica e Pitometria Utilizando Túnel de Vento

SILVA, F. C. 25 July 2012 (has links)
Made available in DSpace on 2016-08-29T15:32:57Z (GMT). No. of bitstreams: 1 tese_5788_Versão para Impressão - Felipe Carvalho da Silva.pdf: 4212685 bytes, checksum: b568855df9c318d051ea61a286599fbb (MD5) Previous issue date: 2012-07-25 / Com os recentes descobertas da indústria petrolífera brasileira relacionadas às reservas no pré-sal, a tecnologia de medição de vazão está sendo re-avaliada, tendo em vista as grandes concentrações de CO2 encontradas nessas reservas. Uma tecnologia que possui níveis de precisão semelhantes aos obtidos com os medidores de vazão utilizados atualmente e que possui as características de independência com relação à composição e propriedades termodinâmicas dos gases é a tecnologia de medição de vazão por velocimetria óptica (OFM). O presente trabalho se dedica a estudo experimental, de comparação das leituras de velocidade entre tubo de Pitot e medidor de vazão por velocimetria óptica. Para isso foi efetuada qualificação e quantificação dos perfis de velocidades dentre as configurações possíveis de escoamento no túnel de vento, propondo metodologia de uso de retificadores de fluxo e amortecimento das leituras obtidas com o tubo de Pitot, e análises de leituras realizadas com o sensor óptico visando avaliar os efeitos de instalação do dispositivo nos resultados obtidos. Os resultados indicam que medidores de vazão ópticos por tempo de trânsito, para níveis médios e altos de velocidade, podem fornecer leitura coesa da vazão mesmo estando num desalinhamento do até ±5º, apesar de constar no manual de instalação do fabricante, garantia destes resultados do medidor quando num desalinhamento de, no máximo, até 2%. Com relação ao efeito intrusivo do sensor óptico nas leituras simultâneas com o tubo de Pitot, percebe-se, em geral, que a partir de aproximadamente Re>&#61472;205x103, o efeito intrusivo desta influência foi suprimido por outros efeitos. Por fim, temos que para uma devida caracterização do escoamento por meio de pitometria, para comparação com a medição Laser, e alcançar satisfatórios resultados com o tubo de Pitot foi necessário fazer-se uso de dispositivos específicos de retificadores de fluxo e de amortecimento (dumping) dos valores medidos. Palavras-chave: medidor de vazão por velocimetria óptica (OFM), Laser two focus (L2F), pitometria, Pré-sal.