111 |
Ventilação natural na construção civil: análise de alternativas para implantação de sistemasSpinelli, Rodrigo 20 August 2015 (has links)
Submitted by FERNANDA DA SILVA VON PORSTER (fdsvporster@univates.br) on 2016-04-12T19:49:22Z
No. of bitstreams: 3
license_text: 22064 bytes, checksum: ef48816a10f2d45f2e2fee2f478e2faf (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
2015RodrigoSpinelli.pdf: 9322349 bytes, checksum: 3464489aab5898a028b17d30c3e31c59 (MD5) / Approved for entry into archive by Ana Paula Lisboa Monteiro (monteiro@univates.br) on 2016-04-14T21:18:45Z (GMT) No. of bitstreams: 3
license_text: 22064 bytes, checksum: ef48816a10f2d45f2e2fee2f478e2faf (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
2015RodrigoSpinelli.pdf: 9322349 bytes, checksum: 3464489aab5898a028b17d30c3e31c59 (MD5) / Made available in DSpace on 2016-04-14T21:18:45Z (GMT). No. of bitstreams: 3
license_text: 22064 bytes, checksum: ef48816a10f2d45f2e2fee2f478e2faf (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
2015RodrigoSpinelli.pdf: 9322349 bytes, checksum: 3464489aab5898a028b17d30c3e31c59 (MD5) / Nos últimos anos tem se ampliada a preocupação com o planejamento adequado da construção civil e o aproveitamento das características climáticas do local onde será executada uma edificação. Com o problema energético surgido nas últimas décadas, os sistemas de climatização artificial, um dos elementos que mais demandam a utilização de energia elétrica, demonstram a necessidade de serem repensados. O objetivo da pesquisa foi de avaliar a viabilidade de utilização de um sistema de climatização natural, com capacidade de resfriamento do ar captado, em protótipos localizados na área de atuação de clima subtropical. Foram executados quatro protótipos com sistemas de ventilação natural, diferentes entre si, porém com materialidade similar a executada comercialmente em larga escala. A pesquisa exploratória desenvolveu-se a partir da medição de dados em quatro protótipos executados para o estudo, localizados na cidade de Lajeado/RS. Foi possível concluir que os sistemas possuem um limite de eficiência, e que para atender de forma adequada padrões de conforto, dependem da análise da influência do entorno próximo (edificações, vegetação, relevo, etc.), análise da utilização de outros elementos de isolamento térmico, elementos construtivos e de climatização natural para se atingir temperatura adequada no interior das edificações para se alcançar níveis de conforto do ambiente construído. / In recent years there has been an increasing concern for the proper planning of construction and the optimal use of climate characteristics of the site where a construction is built. With the emergence of the energy issue in the last few decades, the artificial air conditioning ventilation systems, one of the elements that require the use of electricity, point that needs a rethinking. The purpose this study was to assess the feasibility of using a natural ventilation/cooling system with the capacity of cooling captured air in prototypes located in subtropical climate areas. Four prototypes were built with natural ventilation systems, one different from the other, though all with the same material which was also the one used commercially on a large scale. This exploratory research was based on measuring data of prototypes developed for the study, which were made in the city of Lajeado/RS (Southern Brazil). It was concluded that the systems have a limited efficiency and to meet adequately standards of comfort depend on the analysis of the influence of the immediate surroundings (buildings , vegetation , relief, etc.) , analysis of the use of other insulating elements thermal, structural elements and natural cooling to achieve adequate temperature inside the buildings to achieve comfort levels of the built environment.
|
112 |
Perturbações do sono em doentes com limitação crônica ao fluxo aéreoMarchiori, Roseane Cardoso January 1992 (has links)
Este estudo foi realizado prospectivamente, para descrever o quadro polissonográflco de pacientes com limitação crônica ao fluxo aéreo e para testar a hipótese de que a qualidade do sono destes pacientes é semelhante à de pessoas sem pneumopatia mas com queixas de sono perturbado. Foi criado um índice de qualidade do sono, composto por escores atribuídos a cinco variáveis polissonográflcas, totalizando de zero a dez pontos. Foram estudados 22 pacientes consecutivos (16 homens, sete mulheres), portadores de limitação crônica ao fluxo aéreo, com sintomas há mais de três anos, idade mínima de 18 anos. O grupo controle foi composto por 11 pacientes (oito homens, três mulheres), que procuraram o Laboratório do Sono da Santa Casa de Misericórdia, para avaliação de distúrbio do sono. Os pacientes com limitação crônica ao fluxo aéreo tinham idade (média ± um desvio padrão) de 54 ± 16 anos, com variação de 21 a 73 anos: a altura foi de 1,68 ± 0,07 metro, com variação de 1,68 a 1,84 metro: o peso foi de 71 ± 14 quilogramas, com variação de 54 a 108 quilogramas e o índice de massa corporal foi 25,0 ± 3,6 Kg / m2, com variação de 20,4 a 34,0 Kg/m2. A relação VEF1 / CVF foi, em média, 47 ± 18 %, com variação de 24 a 67%. O volume expiratório forçado em um segundo foi, em média, 1,30 ± O,71 litro, com variação de 0,39 a 3,43 litro, o que correspondeu a 39 ± 17 % do previsto, com variação de 12 a 69%. Houve 39 ± 27 % de melhora do VEF1, 15 minutos após o uso de broncodUatador, com variação de 14 a 120 %. Nos pacientes em estudo, a dificuldade em iniciar o sono esteve associada à dificuldade em manter o sono ( p O,Ol), à hipoxemia em vigília (p=0,04), bem como à presença de disritmias respiratórias (p=0,006). A presença de disritmias respiratórias associou-se, também, a uma latência ao sono REM prolongada. A menor percentagem de sono de ondas lentas correlacionou-se com maior número de movimentos corpóreos (p=0,02) e maior número de despertares com mais de cinco minutos (P= 0,03). O índice de qualidade do sono correlacionou-se com a eficiência do sono (p= 0,06) e com a dessaturação durante o sono (p=0,006). Não se observou correlação entre a saturação máxima de oxigênio arterial e o índice de qualidade do sono (p= 0,30). Assim, é difícil prever, pela oximetria da vigília, a qualidade do sono de um paciente com limitação crônica ao fluxo aéreo. Dois dos 22 pacientes com limitação crônica ao fluxo aéreo tiveram o diagnóstico polissonográfico de síndrome da apnéia do sono. Os grupos diferiram quanto aos dados de saturação máxima, média e mínima de oxigênio, sendo que os pacientes com limitação crônica ao fluxo aéreo apresentaram valores inferiores aos dos controles. Houve diferença, também, quanto aos dados de índice de qualidade do sono e percentagem de estágio 1, sendo que os pacientes com limitação crônica ao fluxo aéreo apresentaram mais sono superficial e índice de qualidade do sono inferior aos dos pacientes do grupo controle. As diferenças persistiram mesmo após a remoção dos dois casos com apnéias. Conclui-se que pneumopatas tem sono mais perturbado do que pacientes que consultaram por distúrbio do sono e que esta perturbação é relacionada à hipoxemia noturna.
|
113 |
Respostas respiratórias à hipóxia e hipercapnia de frangos de corte provenientes de ovos incubados em diferentes temperaturas /Capalbo, Aretuza Carregari. January 2013 (has links)
Orientador: Luciane Helena Gargaglioni Batalhão / Coorientador: Lilian Francisco Arantes de Souza / Banca: Lizandra Amoroso / Banca: Mirela Dias Barros / Resumo: A temperatura é um dos requerimentos fisiológicos fundamental para o bom desenvolvimento embrionário de aves. O objetivo do presente estudo foi avaliar o efeito de alterações da temperatura de incubação sobre parâmetros da incubação (perda de peso dos ovos, eclosão e eclodibilidade, bicagem interna, externa e nascimento e avaliação dos neonatos), ventilação (VE), temperatura corporal (TC) e peso do pulmão e peso do coração em condições basais, e após a exposição à hipóxia (10%O2) ou à hipercapnia (7%CO2) de frango de corte. Foram incubados ovos férteis de matrizes da linhagem Cobb®, com 44 semanas de idade, procedentes de incubatório comercial, de acordo com os seguintes tratamentos: ovos incubados em condições normais de temperatura (37,5ºC); com temperatura elevada (38,5ºC) por 10 dias finais de incubação e com temperatura reduzida (36,5ºC) por 10 dias finais da incubação. Durante a incubação foi observado que a temperatura não afetou eclosão e eclodibilidade. A perda de peso foi maior nos animais incubados em temperatura quente e menor em temperatura fria. A temperatura não influenciou na qualidade dos pintainhos, contudo, ovos incubados em temperatura quente apresentaram redução no tempo de nascimento diferente da temperatura fria que prologa o tempo. Após a eclosão, os animais foram mantidos à temperatura 37,5ºC no 10º e 20º dias de idade e foram avaliados os parâmetros respiratórios e peso do pulmão e coração. Os animais de 10 dias incubados em temperatura fria apresentaram maior resposta ventilatória à hipóxia do que animais incubados em temperatura quente, o que não ocorreu nos animais de 20 dias. Em hipercapnia houve diferença entre os tratamentos tantos em animais de 10 e 20 dias, sendo que animais incubados em temperatura fria apresentaram maior resposta ventilatória com 10 dias e 20 dias comparados ao controle. A hipóxia causou ... / Abstract: The physiological requirements, like temperature, are essential for adequate embryonic development of birds. The aim of this study was to evaluate the effect of changes in temperature on incubation and hatching parameters (eggs' weight loss, hatch and hatchability, internal and external pipping and birth and evaluation of newborns), ventilation (VE), body temperature (Tc) and weight of lungs and heart of broilers in basal conditions and after exposure to hypoxia (10%O2) or hypercapnia (7%CO2). Fertile eggs were incubated arrays Cobb® with 44 weeks old, coming from commercial hatchery, according to the following treatments: eggs incubated at normal temperature (37.5°C), high temperature (38.5°C) and reduced temperature (36.5°C) at 10 final days of incubation. It was observed during incubation that the temperature did not affect hatchability and hatching. The weight loss was greater in animals incubated in high temperature and smaller in warm temperature. The temperature did not affect the quality of the chicks; however, incubated eggs in high temperature decreased the time of birth and cold temperature prolong that time. After hatching, the animals were kept at thermoneutral temperature and between 10 and 20 days old respiratory parameters, the weight of heart and lungs were assessed. Animals of 10 days old incubated in cold temperature had higher ventilatory response to hypoxia than animals incubated in warm temperature, which did not occur in animals of 20 days old. In hypercapnia, there was no difference between treatments in animals of 10 and 20 days old, whereas animals incubated in cold temperature had higher ventilatory response in 10 days and 20 days old compared to control. Hypoxia caused a decrease in Tc in all groups, but the fall was lower at 30 min in animals incubated in warm temperature. Hypercapnia Tc caused to the animals 10 days of age. The weight of lungs and heart ... / Mestre
|
114 |
Efeitos do óxido nitroso e do tipo de ventilação sobre a lactatatemia, glicemia e hemograma, em leitões anestesiados com propofol /Silva, Helen Roberta Amaral da. January 2016 (has links)
Orientador: Newton Nunes / Banca: Vivian Fernanda Barbosa / Banca: Roberto Thiesen / Resumo: Avaliaram-se os efeitos de diferentes concentrações do óxido nitroso (N2O) e oxigênio, sobre os índices de lactato sérico, glicemia e características do hemograma, em suínos anestesiados com propofol e mantidos em ventilação espontânea ou controlada a pressão associada ou não à PEEP. Para isso, 48 animais machos ou fêmeas, foram distribuídos aleatoriamente em seis grupos, denominados, GN10 (FiO2 a 90% e N2O a 10%), GA10 (FiO2 a 90% e ar comprimido a 10%), GN30 (FiO2 a 70% e N2O a 30%), GA30 (FiO2 a 70% e ar comprimido a 30%), GN50 (FiO2 a 50% e N2O a 50%) e GA50 (FiO2 a 50% e ar comprimido a 50%). Empregou-se, como medicação pré-anestésica azaperona (2 mg/kg por via intramuscular), indução anestésica com propofol (dose efeito) bem como manutenção anestésica (0,5 mg/kg/min). Após a intubação o traqueotubo foi acoplado ao aparelho de anestesia inalatória para fornecimento das misturas de gases preconizadas para cada grupo. Após 100 minutos da indução anestésica, foi administrado por via intravenosa rocurônio (0,6 mg/kg IV), seguido de infusão contínua (0,6 mg/kg/hora) e inciou-se a ventilação controlada a pressão (15 cmH2O). A primeira amostra sanguínea foi coletada 20 minutos decorridos da aplicação da azaperona e imediatamente antes da indução anestésica (M0). Após 40 minutos, nova amostra de sangue foi obtida (M1), seguida de mais três colheitas decorridos 100, 175 e 220 minutos da indução da anestesia, tempos estes que coincidiram com o início da ventilação mecânica (M2), i... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effects of different concentrations of nitrous oxide (N2O) and oxygen, on seric level of lactate, glycemia and hematological dynamic, in propofol-anesthetized pigs under spontaneous breathing or in pressure-controlled ventilation with or without PEEP. For this, forty eight animals, males or females, were randomly divided into six groups: GN10 (FiO2 = 90% and N2O = 10%), GA10 (FiO2 = 80% and air = 10%), GN30 (FiO2 = 70% and N2O = 30%), GA30 (FiO2 = 70% and air = 30%), GN50 (FiO2 = 50% and N2O = 50%), GA50 (FiO2 = 50% and air = 50%). Azaperone was administered (2.0 mg/kg IM) as premadication. The induction was performed with propofol at sufficient doses to endotracheal intubation and for the maintenance of anesthesia, the same anesthesic were used (0.5 mg/kg/min). After 100 minutes of the induction, were administered rocuronium (0.6 mg/kg IV) followed by continuous infusion (0.6 mg/kg/h) and started mechanical ventilation (15 cmH2O). Were coleted blood samples in the first moment (M0), twenty minutes after azaperone administration. After forty minutes new blood sample were obtained (M1), followed by three more harvest past 100, 175 and 220 minutes after anesthesia induction (M2, M3 and M4 respectively). The samples were condition in microtubes with sodium fluoride or EDTA. Repeated measures analyses of variance was the statistical method used to evaluate pair wise comparisons of mean were mode, using Tukey's procedure. A P value <0,05 was considered significant. Among the main changes were between groups and moments in HT, RBC, HGB, platelets, WBC, EOS, NS, Lymph, glucose blood and lactate / Mestre
|
115 |
Diferentes concentrações de óxido nitroso ou oxigênio, em suínos anestesiados com propofol e mantidos em ventilação controlada à pressão /Carneiro, Rodrigo Lima. January 2016 (has links)
Orientador: Newton Nunes / Coorientador: João Moreira da Costa Neto / Coorientador: Patrícia Cristina Ferro Lopes / Banca: Vivian Fernanda Barbosa / Banca: Danielli Parrilha de Paula / Banca: Roberto Thiesen / Banca: Paola Castro Moraes / Resumo: Avaliaram-se os efeitos de diferentes concentrações do óxido nitroso (N2O) e da fração inspirada de oxigênio (FiO2) sobre a hematose, os parâmetros cardiorrespiratórios, intracranianos e o índice biespectral, em suínos anestesiados com propofol e mantidos em ventilação controlada a pressão. Para tanto, foram utilizados 48 suínos da raça Large White, machos ou fêmeas, distribuídos aleatoriamente em seis grupos: GN10(FiO2 = 0,9 e N2O = 0,1), GA10 (FiO2 = 0,9 e ar comprimido = 0,1), GN30(FiO2 = 0,7 e N2O = 0,3), GA30(FiO2 = 0,7 e ar comprimido = 0,3), GN50(FiO2 = 0,5 e N2O= 0,5), GA50 (FiO2 = 0,5 e ar comprimido = 0,5). Para todos os suínos, empregou-se como medicação pré- anestésica azaperona (2 mg/Kg) administrada pela via intramuscular. O propofol foi utilizado para indução e manutenção anestésicas (0,5 mg/Kg/min). Após a intubação orotraqueal, a sonda de Magill foi acoplada ao aparelho de anestesia inalatória equipado com ventilador volumétrico/pressométrico, para o fornecimento das misturas gasosas nas concentrações preconizadas para cada grupo. Após 100 minutos da indução anestésica foi administrado bolus, por via intravenosa, de rocurônio (0,6 mg/Kg) seguido por infusão contínua do mesmo fármaco (0,6 mg/Kg/h). Continuamente, iniciou-se a ventilação controlada ciclada a pressão (15 cmH2O) ajustada de maneira a permitir leitura de capnometria entre 35 e 45 mmHg. As observações das variáveis foram realizadas 100 minutos após a indução da anestesia (M0) e em intervalos de 15 ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The effects of different concentrations of nitrous oxide (N2O) and fraction of inspired oxygen (FiO2) on hematosis, cardiorespiratory and intracranial parameters and bispectral index were evaluated in pigs anesthetized with propofol and maintained with pressure-controlled ventilation. Forty-eight Large White pigs, male or female, were randomly assigned into six groups:GN10 (FiO2 = 0.9 and N2O = 0.1), GA10 (FiO2 = 0.9 and compressed air = 0.1), GN30 (FiO2 = 0.7 and N2O = 0.3), GA30 (FiO2 = 0.7 and compressed air = 0.3), GN50 (FiO2 = 0.5 and N2O = 0.5) GA50 (FiO2 = 0.5 and compressed air = 0.5). Azaperone (2 mg/Kg) was used as standard pre-anesthetic medication and Propofol was used to induce and maintain anesthetic state (0.5 mg/Kg/min). Following endotracheal intubation, the Magill tube was coupled to an anesthesial equipped with a special fan which was able to control pressure/ volume of the gas mixture for each studied group. After 100 minutes of anesthetic induction, an intravenous bolus of rocuronium (0.6 mg/Kg) was administered, followed by continuous infusion of the same drug (0.6 mg/Kg/h). Then mechanical ventilation using cycled pressure (15 cmH2O) was adjusted in order to allow capnometry readings in between 35 and 45 mmHg. The observations of the variables were performed 100 minutes after anesthetic induction (M0) and at 15 minute intervals (M15 to M75). Data were subjected to two-way and one-way analysis of variance (ANOVA) followed by Bonferroni correction (p<0.05... (Complete abstract click electronic access below) / Doutor
|
116 |
Comparação da umidade e temperatura dos gases inalados com alto ou baixo fluxo de gases frescos e com ou sem permutador de calor e umidade em anestesia pediátrica /Bicalho, Gustavo Prosperi. January 2013 (has links)
Orientador: José Reinaldo Cerqueira Braz / Banca: Regina Helena Garcia Martins / Banca: David do Nascimento Junior / Banca: Luiz Marcelo Sá Malbouisson / Banca: Flora Margarida Barra Bisinotto / Resumo: O valor mínimo de umidade absoluta (UA) mais frequentemente considerado para prevenção dos efeitos deletérios de gases secos sobre o epitélio das vias aéreas durante anestesia é de 20 mg H2O/L. Como as crianças possuem menor volume minuto, a umidificação dos gases no sistema ventilatório circular pode ser menor na criança que no adulto. O permutador de calor e umidade (PCU) é dispositivo utilizado para umidificar e aquecer adicionalmente os gases inalados durante a ventilação artificial. Com o objetivo de avaliar as propriedades de umidificação de sistema ventilatório circular durante anestesia pediátrica, realizou-se estudo para comparar a temperatura e umidade dos gases inalados com baixo ou alto fluxo de gases frescos (FGF) e com ou sem PCU no circuito ventilatório. Quarenta crianças foram alocadas aleatoriamente em um de quatro grupos segundo a ventilação pulmonar com sistema circular com baixo (1L/min) ou alto (3L/min) FGF sem PCU (grupos 1L e 3L) ou com PCU (grupos PCU1L e PCU3L). A temperatura e UA dos gases inalados foram mensuradas durante 80 minutos após a conexão do paciente ao circuito ventilatório. As médias da temperatura do gás inalado foram maiores nos grupos que utilizaram PCU (PCU1L: 30,3 ± 1,1°C; PCU3L: 29,3± 1,2oC) quando comparadas às dos grupos que não utilizaram PCU (1L: 27,0 ± 1,2°C; 3L: 27,1 ± 1,5oC) (p < 0,0001). As médias de UA dos gases inalados foram maiores nos grupos com PCU em relação aos grupos sem PCU e maiores nos grupos de baixo FGF que nos grupos de alto FGF [(PCU1L: 25 ± 1 mg H20/L) > (PCU3L: 23 ± 2 mg H20/L) > (1L: 17 ± 1 mg H20/L) > (3L: 14 ± 1 mg H20/L)] (p<0,0001). Em sistema ventilatório circular pediátrico, o uso de alto ou baixo FGF não propicia umidificação mínima necessária dos gases inalados para redução do risco de desidratação das vias aéreas. A adição de PCU no circuito ventilatório aumenta a umidade ... / Abstract: An inhaled gas absolute humidity (AH) of 20 mg H2O.L-1 is the minimum value most considered as the threshold necessary for preventing the deleterious effects of dry gas on the epithelium of the airways during anesthesia. Because children have small minute ventilation, we hypothesized that the humidification of a circle breathing system is lower in children compared with adults. A heat and moisture exchanger (HME) is a device that can be used to further humidify inhaled gases during anesthesia. In order to evaluate the humidifying properties of a circle breathing system during pediatric anesthesia we compared the temperature and humidity of inhaled gases under low or high fresh gas flow (FGF) conditions and with or without an HME in the breathing circuit. Forty children were randomly allocated into one of four groups according to the ventilation of their lungs by a circle breathing system with low (1L.min-1) or high (3L.min-1) FGF without an HME (1L and 3L groups) or with an HME (HME1L and HME3L groups). The temperature and AH of inhaled gases were measured for 80 minutes after connecting the patient to the breathing circuit. The mean inhaled gas temperature was higher in HME groups (HME1L: 30.3 ± 1.1°C; HME3L: 29.3 ± 1.2°C) compared with no-HME groups (1L: 27.0 ± 1.2°C; 3L: 27.1 ± 1.5°C) (P < 0.0001). The mean inhaled gas AH was higher in HME than no-HME groups, and higher in low-flow than high-flow groups [(HME1L: 25 ± 1 mg H2O.L-1) > (HME3L: 23 ± 2 mg H2O.L-1) > (1L: 17 ± 1 mg H2O.L-1) > (3L: 14 ± 1 mg H2O.L-1)] (P < 0.0001). In a pediatric circle breathing system, the use of neither high nor low FGF provides the minimum humidity level of the inhaled gases thought to reduce the risk of dehydration of airways. Insertion of an HME in the breathing circuit increases the humidity and temperature of the inhaled gases, bringing them close to physiological values. Therefore, the association of ... / Doutor
|
117 |
Estudo do efeito do sistema sobre a operação de ventiladores. / Study of the system effect on the operation of fans.Böhme, Gustavo Silveira 15 April 2013 (has links)
Efeito do sistema é o nome dado ao decréscimo no desempenho do ventilador que surge quando a instalação deste no sistema não é feita de forma que seja permitido o desenvolvimento completo do escoamento nos trechos de duto em sua entrada ou saída. Esse efeito, muitas vezes não levado em conta durante o dimensionamento de ventiladores associados a sistemas de movimentação de ar, pode causar a insuficiência na vazão de ar ou na pressão requerida para um determinado processo ou objetivo. Este trabalho analisa, para um determinado caso de efeito do sistema, a influência dos parâmetros envolvidos no processo para se melhor compreender este fenômeno. É escolhida para o procedimento experimental, a faixa de velocidades de escoamento em que os dados de fatores do efeito do sistema variam em maior grau nas referências bibliográficas. A metodologia aplicada nos ensaios experimentais é baseada em bibliografias que estudaram diferentes formas de efeito do sistema. Os equipamentos utilizados no processo são escolhidos de forma a atender os fatores restritivos existentes no Laboratório de Instrumentação em Mecânica dos Fluidos da Escola Politécnica da Universidade de São Paulo. Os valores de fator do efeito do sistema obtidos experimentalmente são comparados com os da bibliografia, sendo encontradas diferenças que variam entre 0% e 58%. São buscadas formas de estimar o impacto de cada uma das variáveis envolvidas. O estudo apresentado aqui é de importância para a indústria, devido ao fato de que diferenças de até 200% surgem entre os cálculos de perda de carga que contabilizam o efeito do sistema e aqueles que não contabilizam. / System effect is the name given to the performance decrease of the fan that takes place when the installation of the fans in the system is in a form where the complete development of the flow is not possible to occur in the duct regions in the entrance and exit of the fan. This effect is frequently not considered during the dimensioning of ventilation systems and the selection of the fan for a given process or purpose, which may lead to deficiency in the flow and pressure values when compared to the requirements. The influence of each involved parameter was analyzed in this project for a specific case of system effect in order to better comprehend this phenomenon. The range of airflow speeds chosen for the experimental procedures defined was the one that differed the most in the bibliography. The methodology applied in the experiments was based on bibliography that studied different forms of system effect. The equipment used in the process was chosen to attend to the restrictive factors existent in the Laboratório de Instrumentação em Mecânica dos Fluidos from the Escola Politécnica da Universidade de São Paulo. The values of system effect obtained experimentally were compared to the bibliography, and differences between 0% and 58% were found. A way to estimate the impact of each involved variable was studied. The study present here is quite important to the industry, due to the fact that differences of up to 200% can be found between losses calculations that consider the system effect and those which do not.
|
118 |
Ventilação em blocos habitacionais : qualidade do ar e economia energética. Comparação entre sistemas de extração centralizados e independentesVaz João Henrique da Cunha January 2012 (has links)
Tese de mestrado. Mestrado Integrado em Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2012
|
119 |
Análise experimental da variação da humidade relativa em compartimentosMelão, Daniel Branco January 2009 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Construções Civis). Faculdade de Engenharia. Universidade do Porto. 2009
|
120 |
Aplicação do método de Monte Carlo em simulações higrotérmicas de edifícios.Fonte, Pedro Duarte Pereira Carvalhido Ribeiro da January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2010
|
Page generated in 0.0554 seconds