• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 3
  • 1
  • 1
  • Tagged with
  • 83
  • 38
  • 28
  • 22
  • 22
  • 21
  • 19
  • 19
  • 19
  • 19
  • 19
  • 19
  • 18
  • 18
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Estudio teórico-experimental de un ventilador centrífugo de alabes rectos radiales del Laboratorio de Energía - PUCP

Vargas Alayo, Julio 01 March 2013 (has links)
El presente trabajo de tesis de corte experimental, se realizo utilizando un rotor de álabes rectos radiales (Angulo de ingreso del rotor: β1= β2=90°) Debido a la complejidad en tener un procedimiento para este tipo de ventiladores se compararon procedimientos ya que mediante fórmulas no se tiene un resultado claro sobre valor del ancho del rotor de álabes rectos radiales. Lo primero que se hizo fue comparar los resultados hallados en los ensayos del ventilador ubicado en el laboratorio de energía de la universidad, el estudio consistió en hacer una comparación de resultados hallados con fórmulas establecidas para poder confirmar el cumplimiento de sus resultados. Posteriormente se compararon procedimiento planteados por diferentes estudiosos de ventiladores para poder identificar una aproximación que cumpla con el ventilador estudiado y proponerlo como opción de cálculo o aproximación. Finalmente se propuso una opción de trabajo que se aproximó mas al resultado real pero no es una opción de trabajo ya que no se pudo confirmar que sea factible en diferentes casos. Los resultados obtenidos con las teorías de Bohl, eck y Bleier no llegaron a dar un planteamiento exacto para obtener el ancho del rodete pero los resultados obtenidos utilizando estudios de Bohl fueron los más confiables y cercanos.
62

Sistema de climatización para hotel cuatro estrellas ubicado en la ciudad de Lima

Gutiérrez Giraldo, Daniel 13 June 2011 (has links)
El presente proyecto plantea el diseño de un sistema de climatización para un hotel, categoría cuatro estrellas, ubicado en la ciudad de Lima. Dicho hotel posee once pisos y un sótano, dentro de él se encuentran sesenta y ocho habitaciones, una sala de espera, una sala de estar, un bar, un salón principal con dos foyers (vestíbulos), seis salas de reuniones y un comedor con dos halls (vestíbulos). Previamente al desarrollo del proyecto se establecen definiciones relacionadas con los sistemas de aire acondicionado, componentes y accesorios. A su vez se mencionan normas y recomendaciones a seguir para el diseño. El sistema de climatización planteado como solución brindará confort térmico a los huéspedes y personas que hagan uso de las áreas comunes y de servicio del hotel de acuerdo a las recomendaciones del manual ASHRAE HVAC APLICATIONS 2007 Capítulo 5. Este proyecto contempla la instalación de un chiller (enfriador de agua) tipo tornillo refrigerado por aire de 882.6 kW (252 Toneladas de refrigeración), el cual posee dos bombas en su circuito de bombeo. Ambas bombas son de la misma capacidad ya que trabajarán alternadamente, una de las bombas servirá como respaldo de la otra ante alguna falla. La particularidad del sistema propuesto es el uso de un chiller (enfriador de agua) tipo tornillo con flujo de refrigerante variable. De tal manera que se llega a cumplir con los requerimientos de confort para los distintos ambientes el hotel y a la vez se comprueba el ahorro que pueda lograrse en el monto de inversión comparado con los sistemas convencionales que utilizan chillers (enfriadores de agua) tipo scroll refrigerados por aire.
63

Propuesta técnica de mejora del sistema de ventilación principal de una operación minera subterránea polimetálica - 2015

Portilla Salazar, Renzo Eyreem, Velarde Macukachi, Bryan Pier 15 March 2018 (has links)
El siguiente estudio propone la optimización del sistema de ventilación principal de una minera polimetálica ubicada a 4500 msnm, la cual no cuenta con un modelo computacional actualizado que le permita llevar el control operativo de los flujos de aire circulantes dentro de su red subterránea. La metodología a desarrollar incluye la recolección de data específica (mediciones en campo de las condiciones termo ambiental del flujo de aire en mina), diagnóstico de condiciones actuales y propuestas de optimización. La simulación computacional fue realizada utilizando el software de ventilación VentSim Visual 4. El estudio busca cumplir con todos los requisitos y parámetros normados en el Reglamento de Seguridad Minera DS 024-2016-MEM (MEM, 2016) En la optimización, se evalúan dos alternativas de mejora; primero mediante la construcción de dos ductos “raise borer” principales de gran diámetro y longitud que aseguren la demanda de aire en la profundización de la veta principal, que es, a largo plazo, el futuro de la mina; segundo mediante la eficiencia en el uso de energía de los ventiladores principales mediante la optimización de la demanda de aire de acuerdo al requerimiento total de mina considerando la alternativa de uso de variadores de frecuencia de voltaje en los ventiladores principales de extracción, que tienen una capacidad de extracción de 300 000 CFM. Estas optimizaciones logran reducir el costo operativo en más del 60%, dando un margen de ahorro de más de US$ 200 000 anuales y reduciendo la cantidad de agentes químicos en el aire en un 30%.
64

Diseño de sistema de extracción de emisiones de gases de combustión de biomasa bajo condiciones controladas

Mas Bautista, Ronald Eduardo 25 November 2011 (has links)
El presente trabajo consiste en el diseño de un sistema de extracción de gases de combustión bajo condiciones controladas (velocidad y temperatura), con la finalidad de acondicionar los gases de combustión de la quema de la leña, bosta y yareta para la identificación y cuantificación de las emisiones según normas internacionales. Este sistema se instalará en el Laboratorio de Energía de la Pontificia Universidad Católica del Perú. El diseño de este sistema de extracción se basa en el método 5G de la Agencia del Medio Ambiente de los Estados Unidos de Norteamérica (EPA), que se centra en los procedimientos para la medición del material particulado de estufas estáticas. Esto se complementa con las recomendaciones la Sociedad Americana Gubernamental de la Industria Higiénica (ACGIH), Asociación Americana de Calefacción, Refrigeración y Aire Acondicionado (ASHRAE), Asociación Nacional de Contratistas de Fabricación en Láminas de Metal para Aire Acondicionado (SMACNA), entre otros. Las condiciones nominales de operación del sistema son las siguientes: capacidad de extracción de la mezcla de gases (aire con gases de combustión) 0,27m3/s, temperatura de la mezcla de gases al ingreso del sistema es de 76°C. Estas condiciones se alcanzan cuando en la estufa estática se quema 4.7 kg/hr de combustible (leña). El sistema de extracción cuenta con tres zonas: (i) zona inicial, (ii) zona de estabilización, y (iii) zona de medición. Cada una de ellas cumple con una tarea predeterminada para llevar a cabo el proceso de medición. Las dimensiones de los ductos y accesorios (longitud y diámetro) se estimaron en base a la velocidad recomendada de operación considerando el flujo de extracción de gases obtenido. Los diámetros de los ductos y sus longitudes se encuentran entre 150 mm a 300 mm, y 250 mm a 3030 mm, respectivamente. Así mismo las dimensiones de las chimeneas se obtuvieron después de analizar las condiciones externas (edificaciones contiguas) al Laboratorio de Energía, siendo la altura obtenida de 21,5m. Esta altura garantizaría la correcta dispersión al medio ambiente de los gases de combustión, evitando así la contaminación de los edificios con estos mismos. Sin embargo obtener esta altura no será posible debido a las condiciones en la infraestructura del Laboratorio. Se calcularon las pérdidas de presión en la zona de medición, logrando obtener una caída de presión de 66,59mmH2O, este procedimiento se realizó para realizar la selección del ventilador a usar en esta zona con la finalidad de obtener un control permanente sobre la velocidad del flujo de gases en el interior del sistema de extracción. Finalmente se realizó un cuadro comparativo para las dos propuestas económicas presentadas por las empresas Tecnitemp EIRL e Ingeniería Industrial Arana EIRL para la fabricación del sistema de extracción, siendo la empresa Ingeniería Industrial Arana la que ofrece una mejor propuesta económica para realizar este trabajo.
65

Diseño de un sistema de climatización en aula CAD-CAE

Kutsuma Ogata, Martín Javier 31 October 2011 (has links)
El presente trabajo tuvo como finalidad proponer un sistema de climatización de aire, con el fin de mejorar las condiciones de trabajo en el Laboratorio CAD-CAE y los espacios contiguos (INACOM y oficina). Para esto se analizaron las condiciones previas a la instalación del sistema, recopilándose información trascendente, como las condiciones climáticas. Posteriormente, se establecieron las condiciones ideales, para luego especificar las condiciones que deseadas en el lugar. En el segundo capítulo se refiere a la evaluación de cargas térmicas. Se obtuvo que el 42% de la carga térmica se debe a la fenestración, el 36% por cargas internas, el 8% de la carga es transferida del exterior por las superficies, el 9% se debe a la carga de ventilación y por último el 5% es por infiltración de aire al ambiente acondicionado. Luego en la segunda parte del capítulo, se determinó que es necesario un equipo que extraiga 22.37kW de carga de enfriamiento del laboratorio, 5.22kW del INACOM y 6.29kW de la oficina. Además este debe renovar el aire con una frecuencia de 1.34m3/s en el laboratorio, 0.4 m3/s y 0.6 m3/s en el INACOM y la oficina respectivamente. En el tercer capítulo se seleccionaron los equipos de acuerdo a lo establecido en el capítulo anterior, empleándose manuales, así como catálogos e información complementaria que permita la adecuada selección del equipamiento. Finalmente detallo una evaluación económica referente al costo del sistema seleccionado (US$14,296.70 inc. IGV) y se estableció una comparación con el equipo actual que funciona en dicho establecimiento el cual está sobredimensionado según la capacidad de sus equipos.
66

Instalación de ventilación de laboratorios con extracción de gases

Flores Morales, Allan Walter 13 June 2011 (has links)
La industria minera actual hace uso de diversos procesos químicos y mecánicos para la extracción y refinamiento del mineral explotado, por lo que es fundamental la investigación de este tipo de procesos en un laboratorio. La gran mayoría de estos procesos originan desechos, tales como gases, humos, y vapores, etc., los cuales pueden ser peligrosos si son manejados de manera irresponsable, por lo que se hace necesario su tratamiento. La Especialidad de Ingeniería de Minas se encuentra implementando dos nuevos laboratorios para uso tanto académico como de servicio; estos nuevos ambientes son: el Laboratorio de Hidrometalurgia y el Laboratorio de Pirometalurgia. Estos nuevos laboratorios harán uso de diversos procedimientos metalúrgicos por lo que será necesario implementar un sistema de extracción de sustancias y desechos peligrosos, de tal manera que no se ponga en riesgo la salud de los operarios encargados de hacer los ensayos. Además será necesario tratar estas sustancias luego de ser extraídas de tal manera que puedan ser eliminadas al ambiente con el mínimo de contaminantes. Para este propósito fue necesario investigar acerca de los procesos desarrollados en los laboratorios, los contaminantes emitidos, las posibles soluciones de diseño y los costos del equipo e instalación a utilizar para los fines antes mencionados. Basándose en estas premisas se procedió a diseñar un sistema de extracción compuesto de ductos y accesorios de extracción, asi como de 12 campanas de diversos tamaños (dependiendo de la fuente de contaminación), dos ventiladores de 1.37m3/s con 439,7Pa y 1.16m3/s con 416.87Pa y dos lavadores de gases tipo torre empacada de Ø1.6 y Ø 1.7 de 5 metros de altura con empaque super italox de 1” de plastico, con los cuales se lograría garantizar una eficiencia de 95% de absorción para la concentración de SO2 presente en los gases extraídos. El Costo de la instalación asciende a $42,199 dolares americanos más IGV, el cual incluye el diseño, los materiales y equipos, la instalación del sistema y la obra civil adicional propia del montaje.
67

ESTUDIO DE LA RUTA CELULAR JAK2/STAT3 COMO POTENCIAL INHIBIDOR EN EL MODELO DE FIBROSIS PULMONAR

Hernández Ribes, Gracia 16 May 2016 (has links)
[EN] Idiopathic pulmonary fibrosis (IPF) is the pulmonary disease with higher incidence and worse prognosis. Recent evidence suggests that cucurbitaceae, selective inhibitors of the JAK2/STAT3 pathway, may improve the pathogenesis of IPF, as anti-inflammatory and antioxidative properties have been confirmed in other diseases. However the role in IPF is unknown. Two pharmacological models were investigated in the present study. In the preventive model, Wistar rats were instilled intratracheally with a single dose of bleomycin (BLM)(3.75 U/kg; n=12) to induce lung injury. CuI (20mg/kg/day; n=6) or CuI vehicle (control and IPF group) was administered intraperitoneally daily for 21 days. The therapeutic model was exactly the same starting CuI administration on day 7 until day 21. Animal evolution together with the ventilation-perfusion ratio was controlled through CT/SPECT imaging. Cellular count and characterization was performed in broncoalveolar lavage (BAL) together with the total protein content and the IL-6 and IL-13 concentration in BAL and lung tissue. Hematoxilin-eosin and masson trichrome stains allowed the study of the lung's tissue histology. TGF-ß1, CTGF, COL1A and ET-1 gene and protein expression were both measured by real time PCR and WB as pulmonary vascular remodeling markers. P-STAT3, P-SMAD3 and P-JAK2 proteins were determined by protein and immunohistochemistry quantification. Finally, JAK2 and STAT3 expression and distribution was studied in lung tissue of fibrotic patients with pulmonary hypertension. CT/SPECT quantification showed reduction of the fibrotic areas in the CuI treated group by reestablishing the air space in the lungs back to day 0 levels for the preventive and the therapeutic model. Furthermore, ventilation/perfusion correlation was restored in the therapeutic model after administrating CuI during 14 days. Hematoxilin-eosine stains demonstrated how the group treated pharmacologically presented an improvement in the lung tissue architecture, reversing vascular remodeling and right heart hypertrophy. Masson trichrome stain revealed a reduction of the collagen deposits. Ashcroft score, used to determine the severity of pulmonary fibrosis, was measured and diminished significantly in the CuI treated group. The results showed a gene and protein overexpression of TGF-ß1, CTGF, COL1A and ET-1 in BLM relative to Control rats. This was counteracted with CuI treatment which reduced the expression back to control. In terms of immunohistochemistry, the results demonstrated a decrease in the COL1A deposits in the treated group versus the absence of treatment group. Protein and immunohistochemistry analysis of JAK2, STAT3 and SMAD3 demonstrated an overexpression in bleomycin rats while the protein expression was inhibited in the CuI treated group. In accordance to the results obtained, the immunohistochemistry analysis of the lung parenchyma in patients with pulmonary hypertension related to pulmonary fibrosis showed and overexpression of the phosphorylated forms of JAK2 and STAT3, lacking its expression in healthy lung tissue. The preventive and therapeutic administration of JAK2/STAT3 inhibitor can be a potential treatment for pulmonary fibrosis, as it improves the parameters related to the disease. / [ES] La fibrosis pulmonar idiopática (FPI) es la enfermedad pulmonar con mayor incidencia y peor pronóstico. Estudios recientes sugieren que la familia de las cucurbitaceae, inhibidores selectivos de la ruta JAK2/STAT3, pueden mejorar la patogénesis de la enfermedad, al haberse confirmado sus propiedades antinflamatorias y antioxidantes en otras enfermedades. Sin embargo se desconoce su papel en FPI. En el presente trabajo se estudiaron dos modelos farmacológicos. En el modelo preventivo las ratas Wistar fueron instiladas con una dosis única de bleomicina intratraqueal (BLM)(3.75 U/kg; n=12) para inducir las lesión pulmonar. Durante 21 días se administró CuI (20mg/kg/día; n=6) o vehículo de CuI (control y grupo FPI) por vía intraperitoneal. El modelo curativo se diferencia del preventivo en el comienzo de la administración farmacológica a los 7 días de inducir la enfermedad. El seguimiento de la evolución animal y el ratio de ventilación-perfusión se realizó mediante las técnicas de imagen TC/SPECT. Se realizó el recuento y caracterización de las células totales extravasadas en lavado broncoalveolar (LBA) así como el contenido de proteína total y la concentración de IL- 6 e IL-13 en LBA y tejido pulmonar. Las tinciones de hematoxilina-eosina y masson tricrómico permitieron el estudio de la histología del tejido pulmonar. Se determinó la expresión génica y proteica de TGF-ß1, CTGF, COL1A y ET-1 mediante las técnicas de real time PCR y WB como marcadores de remodelado vascular. Las proteínas P-STAT3, P-SMAD3 y P-JAK2, fueron determinadas mediante cuantificación proteica e inmunohistoquimia. Por último se estudió la expresión y distribución de JAK2 y STAT3 en tejido de pacientes con fibrosis pulmonar e hipertensión pulmonar. La cuantificación de las imágenes TC/SPECT mostraron una reducción de las áreas fibróticas en el grupo tratado con CuI. El tratamiento farmacológico permitió el restablecimiento del espacio aéreo pulmonar hasta valores control en ambos modelos estudiados. El grupo con tratamiento farmacológico restauró el ratio de ventilación/perfusión tras administrar CuI durante 14 días. Las tinciones de hematoxilina eosina revelaron como el grupo animal tratado farmacológicamente presenta una mejora de la histología pulmonar, revirtiendo el remodelado vascular y la hipertrofia del ventrículo derecho. La tinción de masson tricrómico mostró una disminución de los depósitos de colágeno. Se determinó el valor de Ashcroft, evaluador del grado de fibrosis pulmonar, que descendió significativamente en el grupo tratado con CuI. Los resultados presentan una sobrexpresión génica y proteica de TGF-ß1, CTGF, COL1A y ET-1 en los grupos de bleomicina frente a las ratas control. Dicha condición fue revertida mediante el tratamiento con CuI que restableció los valores a niveles control. Los análisis proteicos e inmunohistoquíimicos de JAK2, STAT3 y SMAD3 revelaron una sobreexpresión en las ratas con bleomicina mientras que la expresión proteica fue inhibida en el grupo tratado con CuI. En consonancia con los resultados obtenidos, el análisis inmunohistoquímico del parénquima pulmonar de pacientes con FPI e HP asociada muestran una sobreeexpresión de las formas fosforiladas de JAK2 y STAT3 frente a la ausencia de expresión en tejido pulmonar sano. La administración curativa y preventiva de un inhibidor de la ruta JAK2/STAT3 puede ser un potencial tratamiento para la fibrosis pulmonar, ya que mejora parámetros indicativos de la patología. / [CA] La fibrosi pulmonar idiopàtica (FPI) és la enfermetat pulmonar amb major incidència i pitjor pronostic. Estudis recents suggereixen que la família de les cucurbitàcies, Inhibidors selectius de la ruta JAK2 / STAT3, poden millorar la patogènesi de la malaltia, en haver-se confirmat les seues propietats antiinflamatòries i antioxidants En altres patologies. No obstant això es desconeix el seu paper en FPI. En el present treball es van estudiar 2 models farmacològics. En el model preventiu les rates Wistar foren instilades amb una dosi única de bleomicina intratraqueal (BLM) (3,75 U / kg; n = 12) per a induir les lesions pulmonars. Durant 21 dies es va administrar CuI (20 mg / kg / dia, n = 6) o Vehicle de CuI (control i grup FPI) per vía intraperitoneal. El model curatiu es diferència del preventiu en el començament de l'administració farmacológica als 7 dies d'induir l'enfermetat. El seguiment de l'evoluciò dels animals i el ratio de Ventilació-perfusió es va realitzar mitjançant tècniques d'imatge TC/SPECT. Es realitzà el recompte i caracterització de les cèl·lules totals extravasades en el llavat broncoalveolar (LBA). Així com el contingut de proteina total i la concentració d'IL-6 i IL-13 en LBA i teixit pulmonar. Les tincions d'hematoxilina-eosina i tricròmic de Masson van permetre l'estudi de la histologia del teixit pulmonar. Es va determinar l'expressió gènica i proteica de TGF-ß1, CTGF, COL1A i Et-1 mitjançant tècniques de PCR en temps real i WB com marcadors de remodelat vascular. Les proteïnes P-STAT3, P-SMAD3 i P-JAK2, varen ser determinades mitjançant quantificació proteica i inmunohistoquimia. Per últim se estudià l'expressió i distribució de JAK2 i STAT3 en teixit de pacients amb fibrosi pulmonar e hipertensió pulmonar. La quantificació de les imatges TC/SPECT mostraren una reducció de les àrees fibrótiques en el grup tractat amb CuI. El tractament farmacològic permet el restabliment de l'espai aeri pulmonar fins valors de control en els dos models estudiats. El grup amb tractament farmacològic va restaurar el ratio de ventilació/perfusió tras administrar Cul durant 14 dies. Les tincions d'hematoxilina eosina van revelar com el grup animal tractat farmacològicament presenta una Millora de la histologia pulmonar, revertint el remodelat vascular i la hipertròfia del ventricle dret. La tinció de tricròmic de Masson va mostrar una disminució dels dipòsits de col·lagen. Es va determinar el valor d'Ashcroft, avaluador del grau de fibrosi pulmonar, que va baixar significativament a el grup tractat amb CuI. Els resultats presenten una sobreexpressió gènica i proteica de TGF-ß1, CTGF, COL1A i Et-1 en els grups de bleomicina en comparacióa les rates control. Aquesta condició va ser revertida mitjançant el tractament amb CuI que va restablir els valors fins a nivel dels control. A nivell immunohistoquímic els resultats mostren una disminució dels dipòsits de COL1A en el grup tractat comparativament al grup sense tractament. Els anàlisi proteics i inmunohistoquíimics de JAK2, STAT3 i SMAD3 van revelar una sobreexpressió en les rates amb bleomicina mentre que l'expressió proteica va ser inhibida en el grup tractat amb CuI. D'acord amb els resultats obtinguts, l'anàlisi immunohistoquímic del parènquima pulmonar de pacients amb FPI i HP associada mostren sobreeexpresió de les formes fosforilades de JAK2 i STAT3 davant l'absència d'expressió en teixit pulmonar sa. La administració curativa i preventiva d'un inhibidor de la ruta JAK2 / STAT3 pot ser un potencial tractament per la fibrosi pulmonar, ja que millora paràmetres indicatius de la patologia. / Hernández Ribes, G. (2016). ESTUDIO DE LA RUTA CELULAR JAK2/STAT3 COMO POTENCIAL INHIBIDOR EN EL MODELO DE FIBROSIS PULMONAR [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/64087
68

Estudio de la aplicación de un sistema de climatización con rueda desecante en la selva del Perú

Mendoza Acosta, José Raúl 13 August 2024 (has links)
Los sistemas de climatización por desecantes han surgido como alternativas eco amigables en comparación a los equipos de aire acondicionado tradicionales. Estos sistemas se caracterizan por utilizar desecantes (sólidos o líquidos) que mediante la adsorción retiran humedad del aire. Adicionalmente, pueden emplear fuentes de energía residual o renovable como la solar. No obstante, en la actualidad hay una limitante en el desempeño del sistema al generar bajos valores de COP. Por ello, se desarrolló un estudio de la aplicación de estos sistemas alternativos a una región tropical del Perú, como es Iquitos. En primer lugar, se investigó el estado del arte de los sistemas HVAC basados en desecantes y se identificó los parámetros más relevantes en la operación de la rueda desecante. Seguidamente, se determinó las condiciones ambientales a evaluar, así como las de confort térmico, y se propuso dos arreglos posibles para dichas características. Estos arreglos son sistemas de doble etapa debido a la alta temperatura y humedad presente en la región tropical peruana. Posteriormente, se realizó simulaciones de los arreglos propuestos a diferentes niveles de temperatura de regeneración, y se determinó que el sistema TSDCS-V basado en el ciclo Pennington es el óptimo para la región de Iquitos. El análisis fue en base, principalmente, al coeficiente de desempeño (COP) logrado. Finalmente, se evaluó la propuesta final en un caso estudio comparándolo a una unidad convencional de aire acondicionado. Los resultados demostraron que, desde la perspectiva energética, los sistemas tradicionales son más eficientes puesto que los alternativos presentan aún limitantes tecnológicas. Además, desde la perspectiva ambiental se comprobó que se puede reducir la huella de carbono si ambos sistemas trabajan en conjunto. Incluso, si se empleara fuentes de calor residual o solar para la regeneración, se reduciría considerablemente el consumo energético y, por ende, las emisiones de CO2.
69

Diseño general de un módulo de vivienda sostenible con materiales eficientes / General design of a sustainable housing module with efficient materials

Herrera Navas, Marcela Berenice, Oyola Matta, Carlos Alberto 19 August 2019 (has links)
Un gran porcentaje de las viviendas construidas en Latino América son producto de la autoconstrucción, es decir, no cuentan con estudios preliminares, licencias de construcción, supervisión profesional, son construidas con materiales inadecuados, presentan deficiencia estructural y están ubicadas en zonas no aptas para la construcción. Esto genera peligro a la población, a pesar de que se realice mediante procesos constructivos convencionales sugeridos y asistidos por los maestros de obra. En los primeros meses de 2017, se registraron intensas lluvias debido al Fenómeno del Niño Costero, y se generaron importantes daños en viviendas y carreteras en la Costa de Latino América. Las obras de reconstrucción no se han realizado y existe una gran cantidad de familias damnificadas que esperan acceder a una vivienda segura. En la presente investigación se desarrolló la propuesta de un diseño general de vivienda modular sostenible basado en la Construcción Vernácula a través del uso de materiales eficientes como la caña, la madera, la fibra paja y el barro. / A large percentage of homes built in Latin America are the result of the self-construction, which in most cases means, they do not have preliminary studies, building permits, professional supervision, are built with inadequate materials have structural deficiency and are located in unsuitable areas for construction; despite the fact that it is carried out through conventional constructive processes suggested and assisted by the construction masters it still generates danger to the population. In the first months of 2017, intense rains were recorded due to the El Niño Coastal Phenomenon, and significant damage was caused to homes and roads in the Latin American Coast. The reconstruction works has not been carried out and there are many families affected who hope to access safe housing. In the present investigation the proposal of a general design of sustainable modular housing based on Vernacular Construction was developed with efficient materials such as cane, wood, straw fiber and mud. / Trabajo de investigación
70

Diseño del sistema de ventilación mecánica y aire acondicionado para las áreas de biocontención de tuberculosis del Hospital Maria Auxiliadora - Lima

Diaz Padilla, Milton Williams January 2016 (has links)
El documento digital no refiere un asesor / Publicación a texto completo no autorizada por el autor / Diseña un sistema de ventilación mecánica y aire acondicionado para las áreas de biocontención de tuberculosis del Hospital María Auxiliadora que cumpla los estándares de la OMS (Organización Mundial de la Salud) en el Manual de Bioseguridad en el Laboratorio de Tuberculosis y afines, así también en la Norma UNE 100713 de Instalaciones de Acondicionamiento de Aire en Hospitales y la Norma ASHRAE 170-2008 de Ventilación de Instalaciones en Centros de Salud. Para el desarrollo de este trabajo se toma como base los planos de arquitectura de las áreas de biocontención de tuberculosis, realizando posteriormente los cálculos y criterios para definir la cantidad de aire necesaria que se necesita suministrar y extraer de estos ambientes y evitar la contaminación cruzada con un balance de flujos de aire entre salas. El aire suministrado deberá pasar previamente por un banco de filtros los cuales garantizarán la adecuada limpieza del mismo. / Trabajo de suficiencia profesional

Page generated in 0.0635 seconds