• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 1
  • Tagged with
  • 31
  • 31
  • 27
  • 27
  • 18
  • 10
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Parâmetros oftálmicos em cachorro-do-mato (Cerdocyon thous, Linnaeus, 1766)

Renzo, Roberta [UNESP] 19 November 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-11-19. Added 1 bitstream(s) on 2016-04-01T18:00:54Z : No. of bitstreams: 1 000860264.pdf: 11975335 bytes, checksum: 933d99aa32827700877c6ba0ecab0dd4 (MD5) / Cachorros-do-mato (Cerdocyon thous) figuram entre os animais selvagens mais assistidos em centros de reabilitação, tornando imperioso ampliarem-se conhecimentos sobre parâmetros morfofisiológicos próprios à espécie. Na presente pesquisa, avaliaram-se as condições oftálmicas de 16 cachorros do mato (n=32 olhos). No estudo clínico, avaliaram-se oito indivíduos, sob contenção química, à teste lacrimal de Schirmer I (TLS I), à tonometria digital de aplanação (PIO), à microscopia especular de não contato (espessura corneal, densidade, área e hexagonalidade celulares endoteliais corneais), à ultrassonografia em modos A e B (biometria, notadamente o diâmetro axial, a profundidade das câmaras anterior e vítrea, e a espessura da lente) e à eletrorretinografia (amplitudes e tempos implícitos de ondas a e b, nas fases escotóptica e fotóptica). Córneas, colhidas post mortem, de outros oito animais, foram avaliadas à histologia, quanto às espessuras da córnea e do epitélio, e aos parâmetros de birrefringência (que informam sobre agregação e orientação) de fibras lamelares colágenas estromais, empregando-se morfometria, luz polarizada e software de análise de imagens. Parâmetros de birrefringência foram quantificados como níveis de cinza médio (GA). Em relação ao TLS I e a PIO, verificaram-se valores médios de 13,37±0,94 mm e 10,43±0,96 mmHg, respectivamente. A espessura corneal média foi de 0,53±0,01mm. Relativamente às células endoteliais corneais, os valores médios de densidade e de área foram, respectivamente, de 2.850,38±137,28 cell/mm2 e de 389,00±0,17 μm2. O valor médio de hexagonalidade foi 60,06±4,66 %. Em relação à biometria, verificaram-se valores de 15,93±0,28 mm para diâmetro axial, de 3,29±0,14 mm para profundidade de câmara anterior, de 6,02±0,11 mm para espessura da lente e de 6,61±0,21 mm para profundidade da câmara vítrea. À eletrorretinografia, na fase... / Crab-eating foxes (Cerdocyon thous) are one of the wild animals most attended in rehabilitation centers, making it imperative to extend current knowledge of morphophysiological parameters specific to the species. This study assessed the ophthalmic conditions of 16 crab-eating foxes (n=32 eyes). Eight individuals were clinically assessed, under chemical restraint, by the Schirmer tear test I (STT I), digital applanation tonometry (IOP), non-contact specular microscopy (corneal thickness, density, area and corneal endothelial cell hexagonality), ultrasound in A and B modes (biometrics, particularly axial diameter, anterior and vitreous chamber depths and lens thickness) and electroretinography (amplitudes and implicit times of a- and b-waves, in scotopic and photopic phases). Corneas, collected post mortem from another eight individuals, were evaluated histologically to determine cornea and epithelium thickness and the birefringence parameters (data regarding aggregation and orientation) of lamellar collagenous stromal fibers, using morphometry, polarized light and image analysis software. Birefringence parameters were quantified as gray average (GA) values. Regarding the STT I and IOP, mean values of 13.37±0.94 mm and 10.43±0.96 mmHg were respectively verified. The mean corneal thickness was 0.53±0.01 mm. The mean density and area values of corneal endothelial cells were respectively 2850.38±137.28 cell/mm2 and 389.00±0.17 μm2. The mean value for hexagonality was 60.06±4.66 %. Concerning biometrics, the following mean values were verified: axial diameter, 15.93±0.28 mm; anterior chamber depth, 3.29±0.14 mm; vitreous chamber depth, 6.61±0.21 mm; and lens thickness, 6.02±0.11 mm. Electroretinography in the low amplitude scotopic phase showed values for mean amplitude and b-wave implicit time (20 min adaptation) of 87.33±5.36 μV and 73.10±1.12 ms, respectively. In the high amplitude scotopic phase, the mean amplitude value ...
22

Parâmetros oftálmicos em espécimes de Cuniculus paca criadas em cativeiro

Balthazar da Silveira, Camila Pinho [UNESP] 18 July 2014 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-18Bitstream added on 2015-04-09T12:47:48Z : No. of bitstreams: 1 000814940.pdf: 597654 bytes, checksum: 4531976d9302ffa42846aedaf30f93a5 (MD5) / Conhecimentos gerados a partir de estudos específicos são necessários para a abordagem frente às diferentes afecções oftálmicas. Variações nos parâmetros oftálmicos entre as espécies podem ocorrer, notadamente para as espécies selvagens. Para tanto, estudaram-se alguns parâmetros oftálmicos em 13 indivíduos de espécimes de Cuniculus paca, quantificando-se a produção lacrimal, avaliando-se a bactérias da microbiota conjuntival, a pressão intraocular e o endotélio corneal. Empregou-se o Teste Lacrimal de Schirmer, a tonometria de , e a microscopia especular de não contato para avaliação das variáveis. A microbiota conjuntival foi avaliada por meio de cultura “Brain Heart Infusion” (BHI) e “Polimerase Chain Reaction” (PCR) investigando-se a presença dos microorganismos Staphylococcus aureus, Staphylococcus spp., Streptococcus spp. e Pseudomonas spp. Ao teste lacrimal de Schirmer I, os resultados foram, na média, 4,10±0,44 mm/min, não houve diferença significativa entre os olhos direito e esquerdo (p = 0,8275). A média da PIO foi de 6,34 ± 0,43 mmHg, sem diferença significativa entre os olhos direito e esquerdo (p= 0,9314). O exame oftálmico revelou conjuntiva bulbar pigmentada em coloração marrom-azulada, cílios verdadeiros, apenas em pálpebra superior e pontos lacrimais superior e inferior, além de íris com coloração marrom, pupila circular e vestígio da membrana nictitante. Encontraram-se retinas anangióticas. Identificou-se que 100% dos indivíduos foram positivos para as bactérias Staphylococcus spp. e Streptococcus spp, 80% para Pseudomonas spp e todos foram negativos para Staphylococcus aureus. As médias e erro padrão, no que concerne à espessura corneal foram de 0,353 ± 0,010 mm. Quanto à área foram de 486,30 ± 9,56 μm2; à densidade de células endoteliais, foram de 2083,15 ± 42,47 céls/mm2 e em relação à hexagonalidade, de 67,07 ± 3,30 %. Com os resultados obtidos ... / Knowledge generated through specific studies is necessary for an approach about ophthalmic affections. Ophthalmic parameter variations may occur between species, specially regarding feral ones. Therefore, some ophthalmic parameters were studied in 13 Cuniculus paca individuals. Lacrimal production was quantified, corneal endothelium, intraocular pressure and also bacterial presence at the conjunctival microbiota were evaluated. Schirmer’s tear test, applanation tonometry and non-contact specular microscopy were employed in order to evaluate the variables. Conjunctival microbiota was evaluated through Brain Heart Infusion (BHI) culture and Polimerase Chain Reaction (PCR), so the presence of Staphylococcus aureus, Staphylococcus spp., Streptococcus spp. and Pseudomonas spp. microorganisms was investigated. Schirmer’s test I results were 4.10±0.44 mm/min, and there has been no significant difference between right and left eyes (p = 0.8275). IOP average range was 6.34 ± 0.43 mmHg, with no significant difference between right and left eyes (p= 0.9314). Ophthalmic examination revealed (blue/brown) pigmented bulbar conjunctiva, real eyelashes (only at superior eyelid), superior and inferior lacrimal points, brown iris, round pupil and nictitating membrane vestige. Anangiotic retinas were found. 100% of the individuals tested positive for Staphylococcus spp. and Streptococcus spp., 80% for Pseudomonas spp. and all of them tested negative for Staphylococcus aureus. Averages and standard errors, concerning corneal thickness were 0.353 ± 0.010 mm; regarding to area: 486.30 ± 9.56 μm2; referring to endothelial cells density: 2083.15 ± 42.47 cells/mm2; and relating to hexagonality: 67.07 ± 3.30%. The results obtained allow the conclusion that parameters set through this study might be used as reference to future ones, and also contribute to ophthalmopathy treatment and species preservation
23

Biometria ocular ultrassonográfica e dopplerfluxometria das artérias oftálmica interna e central da retina em macaco-prego (Sapajus spp)

Rodas, Natália Rodrigues [UNESP] 04 August 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:33:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-08-04. Added 1 bitstream(s) on 2015-06-18T12:48:08Z : No. of bitstreams: 1 000831444_20171201.pdf: 50291 bytes, checksum: cebfcf8082b999b88432c5da81ea1dec (MD5) Bitstreams deleted on 2017-12-01T14:40:41Z: 000831444_20171201.pdf,. Added 1 bitstream(s) on 2017-12-01T14:41:31Z : No. of bitstreams: 1 000831444.pdf: 463372 bytes, checksum: 5e0074216ce198fab9293c8d306977e7 (MD5) / O trabalho teve por objetivo avaliar as variáveis biométricas do bulbo ocular utilizando a ultrassonografia ocular modos A e B, bem como realizar a dopplerfluxometria das artérias oftálmica interna e central da retina em macacos-prego. Foram avaliados 18 animais (36 olhos) de macacos-prego (Sapajus spp.) mantidos em cativeiro, sendo 10 fêmeas e 8 machos, clinicamente sadios. As mensurações (em mm) da câmara anterior (D1), espessura da lente (D2), câmara vítrea (D3) e comprimento axial do bulbo ocular (D4) foram feitas, bem como a dopplerfluxometria das artérias oftálmica interna e central da retina, representada por velocidade de pico sistólico (VPS), diastólica final (VDF), ambas em cm/s, índice de resistividade (IR) e de pulsatilidade (IR). As mensurações biométricas médias encontradas no exame ocular ultrassonográfico modo B e modo A foram; Modo B: D1= 2,79 ± 0,19; D2= 3,25 ± 0,22; D3= 10,17 ± 0,48; D4=16,23 ± 0,50; Modo A: D1= 2,16 ± 0,16; D2=3,12 ± 0,14; D3=11,12 ± 0,27; D4= 16,38 ± 0,34. Na dopplerfluxometria da artéria oftálmica interna, os seguintes valores médios das variáveis dopplerfluxométricas foram obtidos: IR=0,71± 0,03; IP=1,30 ± 0,15; VPS=36,89 ± 10,57; VDF=10,52 ± 3,21; e para a artéria central da retina: IR=0,56 ± 0,04; IP=0,81 ± 0,09; VPS= 21,47 ± 7,23; VDF= 9,95 ± 3,31. Os valores de referência de normalidade obtidos poderão auxiliar no diagnóstico de doenças oculares em macacos-prego, bem como poderão ser utilizados em estudos futuros com a presente espécie / This study aimed to evaluate the ocular biometric variables using ocular ultrasound A mode and B mode and dopplerfluxometry of the the internal ophthalmic and central retinal arteries. Were evaluated 18 animals (36 eyes) of capuchin monkeys in captivity, 10 females and 8 males, clinically healthy. Measurements of the anterior chamber (D1), lens thickness (D2), vitreous chamber (D3) and axial length of the eyeball (D4) were performed, as well as the dopplerfluxometry of the internal ophthalmic and central retinal arteries, represented by peak systolic velocity (PSV), end diastolic velocity (EDV), resistivity index (RI) and pulsatility index (PI). The biometric measurements averages found in ocular ultrasonography B mode and A mode were : B mode: D1= 2,79 ± 0,19; D2= 3,25 ± 0,22; D3= 10,17 ± 0,48; D4=16,23 ± 0,50; A mode: D1= 2,16 ± 0,16; D2=3,12 ± 0,14; D3=11,12 ± 0,27; D4= 16,38 ± 0,34. In the dopplerfluxometry of the internal ophthalmic, average values of the variables obtained were: RI=0,71± 0,03; PI=1,30 ± 0,15; PSV=36,89 ± 10,57; EDV=10,52 ± 3,21; and the central retina artery were: RI=0,56 ± 0,04; PI=0,81 ± 0,09; PSV= 21,47 ± 7,23; EDV= 9,95 ± 3,31. Reference values obtained may aid in the diagnosis of eye diseases in capuchin monkeys, and may be used in future studies with this species
24

Parâmetros oftálmicos em cães adultos da raça Shih Tzu

Kobashigawa, Karina Kamachi [UNESP] 17 January 2014 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-17Bitstream added on 2014-11-10T11:58:32Z : No. of bitstreams: 1 000790841.pdf: 1403465 bytes, checksum: 13018455b5c4c9f88bfd51854fffb6ec (MD5) / Afecções da superfície ocular são frequentes em cães braquicefálicos, pela maior exposição do bulbo do olho e por suas intercorrências. Dentre as raças comumente acometidas, tem-se a Shih Tzu, cujos parâmetros oftálmicos não são conhecidos em sua plenitude e foram, em parte, avaliados nesta pesquisa. Sob contenção física, empregou-se o teste lacrimal de Schirmer, o de ruptura do filme lacrimal, a estesiometria, a biomicroscopia com lâmpada em fenda, a microscopia especular de não contato, a flaremetria a “laser”, a tonometria de aplanação, a ecografia e a oftalmoscopia. Foram estudados 48 olhos em 24 indivíduos machos ou fêmeas, com idades variando entre dois a quatro anos e peso entre cinco a 10 Kg, provenientes de canil de criação. Aos dados aplicou-se a estatística descritiva. Relativamente às médias e aos erros padrão, encontraram-se, quanto ao teste lacrimal de Schirmer, 26,145±0,803 mm/min e à ruptura do filme lacrimal, 13,668±0,538 s. À estesiometria, encontraram-se 2,395±0,071 cm. À biomicroscopia, observaram-se 70,83% dos olhos com entrópio de canto medial, 42% apresentaram pelos em carúncula medial, 33% distiquíase, 27% mácula e 13% melanose corneal. Médias e erros padrão, no que concerne à densidade de células endoteliais, foram de 2221,591±20,161 céls/mm2. Quanto à hexagonalidade, foram de 63,770±1,805 %; quanto à área, foram de 451,895±4,179 mm2; e em relação à espessura corneal, de 0,490±0,007 mm. À flaremetria a “laser”, encontraram-se 1,720±0,216 PC/ms e à tonometria, 16,118±0,460 mmHg. As médias e os erros padrão, à ultrassonografia, foram de 20,255±0,134 mm para diâmetro axial horizontal, de 6,624±0,031 mm para espessura da lente, de 4,064±0,109 mm para profundidade da câmara anterior e de 9,565±0,054 mm para a da vítrea O padrão observado à oftalmoscopia não divergiu do já reportado em indivíduos de ... / Ocular surface diseases are often diagnosed in brachycephalic dogs, since their eyes are more exposed. Among the most commonly affected breeds, Shih Tzu dogs are part listed and this breed’s ophthalmic standards are not totally known. In this study ophthalmic standards of this breed were partly studied under physical restraint. Schirmer tear test, break up time test, aesthesiometry, biomicroscopy, non contact specular microscopy, laser flaremetry, applanation tonometry, ultrasonography and ophthalmoscopy were carried in 48 eyes of 24 male and female dogs, with ages from two to four years, weighing between five and 10 kg. All dogs were from a breeding kennel. Descriptive statistics was applied to the data. Mean and standard error for Schirmer tear test was 26.145±0.803 mm/min, for break up time test was 13.668±0.538 s, for aesthesiometry was 2.395±0.071 cm. When evaluated with biomicroscopy 70.83% of the eyes showed medial entropion, 42% showed caruncle trichiasis, 33% distichiasis, 27% corneal opacity and 13% corneal melanosis. Mean and standard error for endothelial cell density was 2221.591±20.161cells/mm2, for endothelial cell hexagonality was 63.770±1.805 %; for endothelial cell area was 451.895±4.179 mm2; for central corneal thickness was 0.490±0.007 mm, for laser flaremetry was 1.720±0.216 PC/ms, for applanation tonometry was 16.118±0.460 mmHg, for axial lenght was 20.255±0.134 mm, for lens thickness was 6.624±0.031 mm, for anterior chamber was 4.064±0.109 mm and for vitreous chamber was 9.565±0.054 mm. Ophthalmoscopy findings were not different from previous reports in other breeds. According to the results obtained, ophthalmic Shih Tzu standards did not differ from reports in other breeds, except for break up time and Cochet-Bonnet aesthesiometry
25

Parâmetros oftálmicos em diferentes espécies de cervídeos brasileiros mantidos em cativeiro

Crivelaro, Roberta Martins [UNESP] 16 January 2014 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-16Bitstream added on 2014-11-10T11:58:32Z : No. of bitstreams: 1 000790850.pdf: 44012970 bytes, checksum: e9db0e5d90e54a75807c00e53994eee2 (MD5) / Cervídeos da fauna brasileira, muitos dos quais sob risco de extinção, não estão livres de afecções oculares. O conhecimento sobre os parâmetros oftálmicos é particularmente importante, notadamente para o diagnóstico e a terapêutica das oftalmopatias que os acometem. Foram avaliadas a produção lacrimal, empregando-se o teste da lágrima de Schirmer; a pressão intraocular, pela tonometria digital de aplanação; a biometria ocular, à ultrassonografia; a biometria craniana, à paquimetria; e as condições da retina, pela eletrorretinografia. Estudaram-se e compararam-se as espécies Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Blastocerus dichotomus, Odocoileus virginianus e Ozotoceros bezoarticus, livres de afecções oftálmicas. Valores de Schirmer mostraram-se menores que os referidos para animais domésticos e selvagens e não diferiram entre as espécies avaliadas. Valores de pressão intraocular não diferiram das de animais de famílias semelhantes já estudadas. Diferenças entre as espécies foram encontradas relativamente à PIO, estando o maior valor com o O. bezoarticus (19 mmHg) e o menor com o M. nemorivaga (5 mmHg). Animais que habitam áreas de vegetação predominantemente densa exibiram córneas mais espessas. Animais que habitam áreas de vegetação predominantemente aberta, exibiram córneas mais delgadas. Relativamente à espessura da lente e ao comprimento axial do olho, espécies com olhos de maior tamanho foram as de áreas de vegetação fechada e espécies com olhos de menor tamanho corresponderam às de vegetação aberta. A eletrorretinografia não apontou diferenças entre as espécies / Brazilian deer, some of which are at risk of extinction, are not free from ophthlamic lesions. Knowledge about ophthalmic parameters is particularly important, especially for diagnostics and therapeutics of ophthalmopaties that can affect them. At this study, tear production, measured with Schirmer tear test, introcular pressure, measured with applanation tonometry, ocular biometry, measured from ultrasonographic images, head biometry, using a caliper rule, and retina conditions, by electroretinography, were evaluated. Several adult captive deer, from eight different species (Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Blastocerus dichotomus, Odocoileus virginianus e Ozotoceros bezoarticus), free from ophthalmic lesions, were studied and compared. Tear production did not differ between studied species and were lower than values in domestic and other wild animals. Intraocular pressure were similar to other animal from resembling families. IOP data showed differences between species, where the highest values were found in O. bezoarticus (19 mmHg), and the lowest in M. nemorivaga (5 mmHg). Corneal thickness was higher in animals living in areas with dense vegetation, while lower values were found in animals who live in areas with open vegetation. The same correlation could me made when looking at lens thickness and axial lenght, where species with bigger eyes live in areas with dense vegetation, while species with smaller eyes live in areas with open vegatation. Electroretinography did not show differences between species
26

Imunomarcação da óxido nítrico sintase induzível e da metaloproteinase-9 em úlceras corneais químicas de coelhos (Oryctolagus cuniculus - Linnaeus, 1758), tratadas com cetorolaco de trometamina

Lima, Tiago Barbalho [UNESP] 28 February 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-28Bitstream added on 2014-06-13T18:56:32Z : No. of bitstreams: 1 lima_tb_me_jabo.pdf: 771997 bytes, checksum: 40a70c69fd98451018e80c0fa212d383 (MD5) / Estudaram-se os efeitos do cetorolaco de trometamina à 0,5%, sem conservante, quanto ao tempo de epitelização, a alterações clínicas, histológicas (HE), sobre expressão da Óxido Nítrico Sintase induzível (iNOS) e da Metaloproteinase-9 (MMP-9) na ceratite ulcerativa causada por álcali em coelho. Doze olhos foram tratados (GT) com o fármaco e outros 12 com solução salina (GC), imediatamente à ocorrência das úlceras e a cada 6 horas. Decorridas 24h, seis córneas (n=6) de cada grupo foram colhidas (primeiro momento). As demais (n=6), o foram após a reepitelização (segundo momento). Em ambos os momentos, avaliaram-se o infiltrado inflamatório e as condições do epitélio neoformado (HE). Por imunoistoquímica, a imunomarcação de iNOS e de MMP-9 foi avaliada. A média do tempo de epitelização no GT foi de 55 horas. No GC, ele foi de 44 horas (p<0,05). Às 24 h, as córneas do GT apresentaram menor exsudação inflamatória (p<0,01), comparativamente ao GC. No segundo momento, o GT mostrou discreta exsudação inflamatória (p>0,05) e camada epitelial simples. O GC mostrou maior estratificação no epitélio neoformado. A média de imunomarcação de iNOS em células do estroma foi maior em GT, no primeiro e segundo momentos, comparativamente a GC (p>0.05). No segundo momento, a região central expressou mais iNOS, comparativamente à periférica, tanto em GT (p<0,01), quanto em GC (p<0,05). No epitélio, não se observaram diferenças significativas dos escores de imunomarcação de iNOS entre os grupos e os momentos (p=0.69). Os escores de imunomarcação para MMP-9, no epitélio, foram menores em GT, comparativamente a GC (p=0,69). A média de imunomarcação de MMP-9 em células do estroma, no segundo momento, foi maior na região central, comparativamente à periférica (p=0.32). Não houve correlação entre a... / We studied the effects of ketorolac tromethamine at 0.5% without preservative, about the time of epithelialization, the clinical, histological (HE) on the expression of inducible Nitric Oxide Synthase (iNOS) and metalloproteinase-9 (MMP -9) in ulcerative keratitis in rabbits caused by alkali. Twelve eyes were treated (GT) to the drug and 12 with saline (GC), immediately to the occurrence of ulcers and every 6 hours. After 24h, six corneas (n = 6) of each group were harvested (first moment). The other (n = 6), were after reepithelialization (second time). In both instances, we evaluated the inflammatory infiltrate and conditions of the newly formed epithelium (HE). For immunohistochemistry, immunostaining of iNOS and MMP-9 was assessed. The average time of epithelialization in GT was 55 hours. In the GC, it was 44 hours (p <0.05). At 24 h, the corneas of GT showed lower inflammatory exudation (p <0.01) compared to the CG. In the second phase, the GT revealed mild inflammatory exudation (p> 0.05) and simple epithelial layer. The GC showed greater stratification in the newly formed epithelium. The average immunostaining of iNOS in stromal cells was higher in GT, the first and second moments compared to control group (p> 0.05). In the second step, the central region expressed more iNOS compared to peripheral in both TG (p <0.01) and in control group (p <0.05). In the epithelium, there were no significant differences in scores of iNOS immunostaining between groups and time (p = 0.69). The scores of immunostaining for MMP-9 in the epithelium were lower in GT compared to GC (p = 0.69). The average immunostaining of MMP-9 in stromal cells, the second time was greater in the central region as compared to the peripheral (p = 0.32). There was no correlation between the immunostaining of iNOS and MMP-9 as well as the quantity... (Complete abstract click electronic access below)
27

Imunomarcação da óxido nítrico sintase induzível e da metaloproteinase-9 em úlceras corneais químicas de coelhos (Oryctolagus cuniculus - Linnaeus, 1758), tratadas com cetorolaco de trometamina /

Lima, Tiago Barbalho. January 2013 (has links)
Orientador: José Luiz Laus / Coorientador: Alexandre Pinto Ribeiro / Banca: Cristiane dos Santos Honsho / Banca: Ana Lúcia Abreu Silva / Resumo: Estudaram-se os efeitos do cetorolaco de trometamina à 0,5%, sem conservante, quanto ao tempo de epitelização, a alterações clínicas, histológicas (HE), sobre expressão da Óxido Nítrico Sintase induzível (iNOS) e da Metaloproteinase-9 (MMP-9) na ceratite ulcerativa causada por álcali em coelho. Doze olhos foram tratados (GT) com o fármaco e outros 12 com solução salina (GC), imediatamente à ocorrência das úlceras e a cada 6 horas. Decorridas 24h, seis córneas (n=6) de cada grupo foram colhidas (primeiro momento). As demais (n=6), o foram após a reepitelização (segundo momento). Em ambos os momentos, avaliaram-se o infiltrado inflamatório e as condições do epitélio neoformado (HE). Por imunoistoquímica, a imunomarcação de iNOS e de MMP-9 foi avaliada. A média do tempo de epitelização no GT foi de 55 horas. No GC, ele foi de 44 horas (p<0,05). Às 24 h, as córneas do GT apresentaram menor exsudação inflamatória (p<0,01), comparativamente ao GC. No segundo momento, o GT mostrou discreta exsudação inflamatória (p>0,05) e camada epitelial simples. O GC mostrou maior estratificação no epitélio neoformado. A média de imunomarcação de iNOS em células do estroma foi maior em GT, no primeiro e segundo momentos, comparativamente a GC (p>0.05). No segundo momento, a região central expressou mais iNOS, comparativamente à periférica, tanto em GT (p<0,01), quanto em GC (p<0,05). No epitélio, não se observaram diferenças significativas dos escores de imunomarcação de iNOS entre os grupos e os momentos (p=0.69). Os escores de imunomarcação para MMP-9, no epitélio, foram menores em GT, comparativamente a GC (p=0,69). A média de imunomarcação de MMP-9 em células do estroma, no segundo momento, foi maior na região central, comparativamente à periférica (p=0.32). Não houve correlação entre a... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: We studied the effects of ketorolac tromethamine at 0.5% without preservative, about the time of epithelialization, the clinical, histological (HE) on the expression of inducible Nitric Oxide Synthase (iNOS) and metalloproteinase-9 (MMP -9) in ulcerative keratitis in rabbits caused by alkali. Twelve eyes were treated (GT) to the drug and 12 with saline (GC), immediately to the occurrence of ulcers and every 6 hours. After 24h, six corneas (n = 6) of each group were harvested (first moment). The other (n = 6), were after reepithelialization (second time). In both instances, we evaluated the inflammatory infiltrate and conditions of the newly formed epithelium (HE). For immunohistochemistry, immunostaining of iNOS and MMP-9 was assessed. The average time of epithelialization in GT was 55 hours. In the GC, it was 44 hours (p <0.05). At 24 h, the corneas of GT showed lower inflammatory exudation (p <0.01) compared to the CG. In the second phase, the GT revealed mild inflammatory exudation (p> 0.05) and simple epithelial layer. The GC showed greater stratification in the newly formed epithelium. The average immunostaining of iNOS in stromal cells was higher in GT, the first and second moments compared to control group (p> 0.05). In the second step, the central region expressed more iNOS compared to peripheral in both TG (p <0.01) and in control group (p <0.05). In the epithelium, there were no significant differences in scores of iNOS immunostaining between groups and time (p = 0.69). The scores of immunostaining for MMP-9 in the epithelium were lower in GT compared to GC (p = 0.69). The average immunostaining of MMP-9 in stromal cells, the second time was greater in the central region as compared to the peripheral (p = 0.32). There was no correlation between the immunostaining of iNOS and MMP-9 as well as the quantity... (Complete abstract click electronic access below) / Mestre
28

Biometria ocular ultrassonográfica e dopplerfluxometria das artérias oftálmica interna e central da retina em macaco-prego (Sapajus spp) /

Rodas, Natália Rodrigues. January 2014 (has links)
Orientador: Cláudia Valéria Seullner Brandão / Banca: Maria Jaqueline Mamprim / Banca: Zara Bortolini / Resumo: O trabalho teve por objetivo avaliar as variáveis biométricas do bulbo ocular utilizando a ultrassonografia ocular modos A e B, bem como realizar a dopplerfluxometria das artérias oftálmica interna e central da retina em macacos-prego. Foram avaliados 18 animais (36 olhos) de macacos-prego (Sapajus spp.) mantidos em cativeiro, sendo 10 fêmeas e 8 machos, clinicamente sadios. As mensurações (em mm) da câmara anterior (D1), espessura da lente (D2), câmara vítrea (D3) e comprimento axial do bulbo ocular (D4) foram feitas, bem como a dopplerfluxometria das artérias oftálmica interna e central da retina, representada por velocidade de pico sistólico (VPS), diastólica final (VDF), ambas em cm/s, índice de resistividade (IR) e de pulsatilidade (IR). As mensurações biométricas médias encontradas no exame ocular ultrassonográfico modo B e modo A foram; Modo B: D1= 2,79 ± 0,19; D2= 3,25 ± 0,22; D3= 10,17 ± 0,48; D4=16,23 ± 0,50; Modo A: D1= 2,16 ± 0,16; D2=3,12 ± 0,14; D3=11,12 ± 0,27; D4= 16,38 ± 0,34. Na dopplerfluxometria da artéria oftálmica interna, os seguintes valores médios das variáveis dopplerfluxométricas foram obtidos: IR=0,71± 0,03; IP=1,30 ± 0,15; VPS=36,89 ± 10,57; VDF=10,52 ± 3,21; e para a artéria central da retina: IR=0,56 ± 0,04; IP=0,81 ± 0,09; VPS= 21,47 ± 7,23; VDF= 9,95 ± 3,31. Os valores de referência de normalidade obtidos poderão auxiliar no diagnóstico de doenças oculares em macacos-prego, bem como poderão ser utilizados em estudos futuros com a presente espécie / Abstract: This study aimed to evaluate the ocular biometric variables using ocular ultrasound A mode and B mode and dopplerfluxometry of the the internal ophthalmic and central retinal arteries. Were evaluated 18 animals (36 eyes) of capuchin monkeys in captivity, 10 females and 8 males, clinically healthy. Measurements of the anterior chamber (D1), lens thickness (D2), vitreous chamber (D3) and axial length of the eyeball (D4) were performed, as well as the dopplerfluxometry of the internal ophthalmic and central retinal arteries, represented by peak systolic velocity (PSV), end diastolic velocity (EDV), resistivity index (RI) and pulsatility index (PI). The biometric measurements averages found in ocular ultrasonography B mode and A mode were : B mode: D1= 2,79 ± 0,19; D2= 3,25 ± 0,22; D3= 10,17 ± 0,48; D4=16,23 ± 0,50; A mode: D1= 2,16 ± 0,16; D2=3,12 ± 0,14; D3=11,12 ± 0,27; D4= 16,38 ± 0,34. In the dopplerfluxometry of the internal ophthalmic, average values of the variables obtained were: RI=0,71± 0,03; PI=1,30 ± 0,15; PSV=36,89 ± 10,57; EDV=10,52 ± 3,21; and the central retina artery were: RI=0,56 ± 0,04; PI=0,81 ± 0,09; PSV= 21,47 ± 7,23; EDV= 9,95 ± 3,31. Reference values obtained may aid in the diagnosis of eye diseases in capuchin monkeys, and may be used in future studies with this species / Mestre
29

Parâmetros oftálmicos em espécimes de Cuniculus paca criadas em cativeiro /

Balthazar da Silveira, Camila Pinho. January 2014 (has links)
Orientador: José Luiz Laus / Banca: Fabrício Singaretti de Oliveira / Banca: Cristiane dos Santos Honsho / Resumo: Conhecimentos gerados a partir de estudos específicos são necessários para a abordagem frente às diferentes afecções oftálmicas. Variações nos parâmetros oftálmicos entre as espécies podem ocorrer, notadamente para as espécies selvagens. Para tanto, estudaram-se alguns parâmetros oftálmicos em 13 indivíduos de espécimes de Cuniculus paca, quantificando-se a produção lacrimal, avaliando-se a bactérias da microbiota conjuntival, a pressão intraocular e o endotélio corneal. Empregou-se o Teste Lacrimal de Schirmer, a tonometria de , e a microscopia especular de não contato para avaliação das variáveis. A microbiota conjuntival foi avaliada por meio de cultura "Brain Heart Infusion" (BHI) e "Polimerase Chain Reaction" (PCR) investigando-se a presença dos microorganismos Staphylococcus aureus, Staphylococcus spp., Streptococcus spp. e Pseudomonas spp. Ao teste lacrimal de Schirmer I, os resultados foram, na média, 4,10±0,44 mm/min, não houve diferença significativa entre os olhos direito e esquerdo (p = 0,8275). A média da PIO foi de 6,34 ± 0,43 mmHg, sem diferença significativa entre os olhos direito e esquerdo (p= 0,9314). O exame oftálmico revelou conjuntiva bulbar pigmentada em coloração marrom-azulada, cílios verdadeiros, apenas em pálpebra superior e pontos lacrimais superior e inferior, além de íris com coloração marrom, pupila circular e vestígio da membrana nictitante. Encontraram-se retinas anangióticas. Identificou-se que 100% dos indivíduos foram positivos para as bactérias Staphylococcus spp. e Streptococcus spp, 80% para Pseudomonas spp e todos foram negativos para Staphylococcus aureus. As médias e erro padrão, no que concerne à espessura corneal foram de 0,353 ± 0,010 mm. Quanto à área foram de 486,30 ± 9,56 μm2; à densidade de células endoteliais, foram de 2083,15 ± 42,47 céls/mm2 e em relação à hexagonalidade, de 67,07 ± 3,30 %. Com os resultados obtidos ... / Abstract: Knowledge generated through specific studies is necessary for an approach about ophthalmic affections. Ophthalmic parameter variations may occur between species, specially regarding feral ones. Therefore, some ophthalmic parameters were studied in 13 Cuniculus paca individuals. Lacrimal production was quantified, corneal endothelium, intraocular pressure and also bacterial presence at the conjunctival microbiota were evaluated. Schirmer's tear test, applanation tonometry and non-contact specular microscopy were employed in order to evaluate the variables. Conjunctival microbiota was evaluated through Brain Heart Infusion (BHI) culture and Polimerase Chain Reaction (PCR), so the presence of Staphylococcus aureus, Staphylococcus spp., Streptococcus spp. and Pseudomonas spp. microorganisms was investigated. Schirmer's test I results were 4.10±0.44 mm/min, and there has been no significant difference between right and left eyes (p = 0.8275). IOP average range was 6.34 ± 0.43 mmHg, with no significant difference between right and left eyes (p= 0.9314). Ophthalmic examination revealed (blue/brown) pigmented bulbar conjunctiva, real eyelashes (only at superior eyelid), superior and inferior lacrimal points, brown iris, round pupil and nictitating membrane vestige. Anangiotic retinas were found. 100% of the individuals tested positive for Staphylococcus spp. and Streptococcus spp., 80% for Pseudomonas spp. and all of them tested negative for Staphylococcus aureus. Averages and standard errors, concerning corneal thickness were 0.353 ± 0.010 mm; regarding to area: 486.30 ± 9.56 μm2; referring to endothelial cells density: 2083.15 ± 42.47 cells/mm2; and relating to hexagonality: 67.07 ± 3.30%. The results obtained allow the conclusion that parameters set through this study might be used as reference to future ones, and also contribute to ophthalmopathy treatment and species preservation / Mestre
30

Avaliação da opacidade da cápsula posterior, após facoemulsificação e implante de lente intraocular modificada com plasma de flúor ou polietilenoglicol com coelhos /

Sereno, Maria Guadalupe. January 2012 (has links)
Orientador: Cláudia Valéria Seuller Brandão / Coorientador: Antônio Carlos Lotelli Rodrigues / Banca: José Joaquim Titon Ranzani / Banca: Silvana Artioli Schellini / Banca: Georgia Nadalini Rodrigues / Banca: Cláudia Helena Pellizzon / Resumo: A opacidade de cápsula posterior (OCP) é a complicação tardia mais comum após remoção da catarata por facoemulsificação e constitui uma nova barreira à passagem da luz. A modificação superficial das lentes intraoculares (LIOs) e tratamento por plasma vêm sendo estudados, com o intuito de aumentar a biocompatibilidade das mesmas e induzir menor proliferação celular com a posterior manifestação da OCP. O presente estudo teve por objetivo avaliar e comparar a OCP, bem como as variáveis clínico-oftalmológicas após facoemulsificação e implante de lente intraocular (LIO), modificada com plasma de flúor (SF6) ou de polietilenoglicol (PEG), em coelhos. Foram constituídos quatro grupos, de 10 animais cada. Todos os coelhos foram submetidos à facoemulsificação, sendo este o único procedimento no grupo GF; os animais do GL receberam o implante de LIOs hidrofílicas sem tratamento; no GP foram implantadas LIOs tratadas com plasma de flúor, e no GPeg LIOs polimerizadas com plasma de polietilenoglicol. Após o procedimento cirúrgico, foi feita a avaliação macroscópica e semiquantitativa da OCP, opacidade de cápsula anterior (OCA) e fimose capsular, pela lâmpada de fenda, bem como foi mensurada a pressão intraocular (PIO) e analisada espessura corneal e endotélio por microscopia especular. Adicionalmente, foi realizada a fotodocumentação digital por retroiluminação da cápsula posterior foram analisadas quanto à OCP, utilizando-se o software POCOman (Posterior Capsule Opacification Manual), até as doze e 24 semanas do pós-operatório, nos momentos de avaliação precoce e tardia respectivamente. Na avaliação clínica oftalmológica e do endotélio da córnea não houve diferença significativa entre os grupos. A OCP foi menos intensa nos grupos tratados por plasma, na biomicroscopia. O GF apresentou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Intraocular lenses surface modification and plasma treatment are being studied, in order to increase the biocompatibility and induce less cell proliferation with the later manifestation of posterior capsule opacification (PCO). The present study aimed to evaluate and compare the PCO, as well as clinical and ophthalmological variables after phacoemulsification and intraocular lens implantation (IOL), modified with fluoride (SF6) plasma or poly (ethylene) glycol (PEG), in rabbits. Four groups with 10 animals each were constituted. All rabbits were submitted to phacoemulsification, being this the only procedure in GF group; the GL animals received the implant of hydrophilic IOLs; GP received fluoride plasma treated IOLs, and GPeg poly (ethylene glycol) plasma-polymerized IOLs. After the surgical procedure, the PCO macroscopic evaluation was made of the OCP, anterior capsule opacification (OCA) and capsular phimosis by slit-lamp, as well as was measured the intraocular pressure (IOP) and analyzed corneal thickness and endothelium by specular microscopy. Additionally, digital photographs by backlight of posterior capsule were analysed as to the OCP, using the software POCOman (Posterior Capsule Opacification Manual), until the 12 and 24 postoperative weeks in early and late evaluation respectively. In clinical assessing eye cornea and endothelium there was no significant difference between the groups. To slit lamp exam PCO was less intense in the groups treated by plasma. The GF had the highest rates of anterior capsule opacity and capsular phimosis in relation to groups with IOL. POCOman, was not evidenced in effect in reducing the PCO in the group treated by Fluoride in relation to non treated. The implant of IOLs treated with plasma does not promote inflammatory eye signs and endothelial additionally changes, demonstrating... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0973 seconds