Enhancing PV Hosting Capacity of Distribution Feeders using Voltage Profile Design

Jain, Akshay Kumar 06 March 2018 (has links)
Distribution feeders form the last leg of the bulk power system and have the responsibility of providing reliable power to the customers. These feeders experience voltage drops due to a combination of feeder length, load distribution, and other factors. Traditionally, voltage drop was a major concern. Now, due to an ever-increasing PV penetration, overvoltage has also become a major concern. This limits the amount of solar PV that may be integrated. Few solutions exist to improve the voltage profile, where the most common is the use of voltage control devices like shunt capacitors and voltage regulators. Due to a large number of design parameters to be considered, the determination of the numbers and locations of these devices is a challenging problem. Significant research has been done to address this problem, utilizing a wide array of optimization techniques. However, many utilities still determine these locations and numbers manually. This is because most algorithms have not been adequately validated. The validation of a voltage profile design (VPD) algorithm has been presented here. The validation of this algorithm was carried out on a set of statistically relevant feeders. These feeders were chosen based on the results obtained from a feeder taxonomy study using clustering analysis. The algorithm was found to be effective in enhancing the amount of solar PV a feeder may host, while still maintaining all the voltages within the ANSI standard limits. Furthermore, the methodology adopted here may also be used for the validation of other algorithms. / Master of Science / Utilities have the responsibility of providing reliable power supply to their customers. Traditionally, bulk power was generated and transmitted over long distances incurring losses and voltage drops along the way. Now, with the integration of distributed energy resources, particularly solar photovoltaic (PV) generators at the customer locations, overvoltage has also become a problem. This requires adoption of measures which can help in maintaining the voltages within standard limits. Several options exist to compensate for these voltage issues, the most commonly used is voltage control devices like capacitor banks and voltage regulators. However, determining the required numbers of these devices and their appropriate locations is a challenging problem. Even though a number of algorithms have been proposed to give automated solutions to this problem, most utilities still use a manual approach. This is because these algorithms have not been validated on a statistically relevant set of feeders. To solve this issue, the validation of a voltage profile design (VPD) algorithm is presented in this thesis. The ability of this algorithm to enhance the amount of PV that may be connected to a distribution network has been validated on a set of feeders. The feeders were chosen based on the results obtained from clustering analysis, a machine learning concept. The cost effectiveness of this algorithm has also been investigated and significant savings were observed. Furthermore, the methodology adopted here can be easily extended for the validation of other algorithms as well.
2

Quantitative Analysis of Distributed Energy Resources in Future Distribution Networks

Han, Xue January 2012 (has links)
There has been a large body of statements claiming that the large scale deployment of Distributed Energy Resources (DERs) will eventually reshape the future distribution grid operation in numerous ways. However, there is a lack of evidence specifying to what extent the power system operation will be alternated. In this project, quantitative results in terms of how the future distribution grid will be changed by the deployment of distributed generation, active demand and electric vehicles, are presented. The quantitative analysis is based on the conditions for both a radial and a meshed distribution network. The input parameters are on the basis of the current and envisioned DER deployment scenarios proposed for Sweden. The simulation results indicate that the deployment of DERs can significantly reduce the power losses and voltage drops by compensating power from the local energy resources, and limiting the power transmitted from the external grid. However, it is notable that the opposite results (e.g., severe voltage uctuations, larger power losses) can be obtained due to the intermittent characteristics of DERs and the irrational management of different types of DERs in the DNs. Subsequently, this will lead to challenges for the Distribution System Operator (DSO).
3

Estrategias de controle preventivo para a manutenção de margens de segurança com relação a estabilidade de tensão em tempo real / Preventive control strategies for maintaining secure on-line voltage stability margins

Ferreira, Adriana Scheffer Quintela 18 September 2006 (has links)
Orientador: Carlos Alberto de Castro Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-07T10:41:53Z (GMT). No. of bitstreams: 1 Ferreira_AdrianaSchefferQuintela_D.pdf: 931902 bytes, checksum: 723b5bb5e37c4be6978b9a1ba3d8572c (MD5) Previous issue date: 2006 / Resumo: O problema de estabilidade de tensão tem recebido uma atenção crescente dos profissionais que atuam na área de análise e operação de sistemas de potência. O aumento das interligações aliado a operação das redes com altos níveis de carregamento torna mais provável a ocorrência de incidentes que podem levá-las à instabilidade de tensão, culminando com o colapso de tensão e grandes prejuízos à qualidade do fornecimento de energia elétrica. Ações de controle preventivo e/ou corretivo devem ser tomadas para melhorar a segurança de sistemas de potência. Este trabalho de pesquisa aborda a manutenção da segurança de redes com relação à estabilidade de tensão, através do estudo e da implementação de estratégias de controle preventivo, ou seja, que impedem a ocorrência de situações de instabilidade de tensão antes destas efetivamente ocorrerem. Além disso, são propostas filosofias práticas da utilização dos recursos disponíveis para mitigar o colapso de tensão, de maneira que uma margem de segurança com relação à estabilidade de tensão (MSET) apropriada e um perfil de tensão (PT) adequado sejam respeitados. Uma característica importante da metodologia proposta é que o problema de programação não linear a ser resolvido tem pequena dimensão, mesmo para sistemas de grande porte, pois apenas os controles mais eficientes são considerados e o número de restrições é limitado. A inovação consiste em atender uma meta de segurança sem a utilização plena de alguns dos recursos disponíveis, preservando os controles mais sensíveis e os pouco disponíveis para futura utilização em caso de emergências, mesmo após a ocorrência de certas contingências. A valia-se o potencial de utilização do processo proposto no ambiente de operação de redes em tempo real. Objetivou-se desenvolver um algoritmo capaz de identificar ações de controle preventivo apropriadas de forma a serem rapidamente implementadas / Abstract: The voltage stability problem has been receiving a growing attention from the professionals in the area of analysis and operation of power systems. The growth in interconnections along with the networks' operation with high loading levels makes the occurrence of incidents that can lead to voltage instability more likely, culminating with the volt age collapse and serious damages to the quality of the electric power supply. Preventive and/or corrective control actions should be taken to improve the power systems' security. This research work deals with the maintenance of network' security with respect to voltage stability, through the study and implementation of preventive control strategies, that prevent the occurrence of volt age instability situations before those effectively take place. Moreover, practical philosophies for using the available resources to mitigate the volt age collapse are proposed, so that an appropriate volt age stability security margin (VSSM) and an appropriate voltage profile (VP) be respected. An important feature of the proposed methodology is that the resulting nonlinear programming to be solved is small, even for large systems, since only the most effective controls are considered and the number of constraints is limited. The innovation consists of meeting a security target without the full use of some of the available resources. The proposed formulation preserves the most sensitive and the least available controls for future use in case of further emergencies, even after the occurrence of certain contingencies. The potential of use of the proposed process is evaluated in the real time operation environment. The objective was to develop an algorithm capable of identifying appropriate preventive control actions that can be quickly implemented. / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
4

[en] LOSS OF CONTROL AND INADEQUATE VOLTAGE CONTROL ACTION IN THE EVALUATION OF VOLTAGE STABILITY CONDITIONS / [pt] PERDA E INADEQUAÇÃO DO CONTROLE DE TENSÃO NA AVALIAÇÃO DAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO

OSCAR CUARESMA ZEVALLOS 03 February 2015 (has links)
[pt] Esta pesquisa está relacionada à avaliação das condições de estabilidade de tensão em pontos de operação do sistema elétrico. A modelagem de geradores / compensadores síncronos e compensadores estáticos são analisadas. Estabeleceram-se os melhores modelos com controle de tensão ativo e com perda do controle. A questão da adequação do controle de tensão foi tratada através da análise dos elementos da matriz de sensibilidade entre as grandezas controladoras e as tensões controladas. Os índices de estabilidade de tensão foram calculados. Em todos os casos, a perda de controle de tensão tem impacto negativo sobre as condições de estabilidade de tensão. Nos casos com ação de controle inadequada, independe da relação inversa entre grandeza controladora e tensão controlada, um aumento da tensão na barra controlada teve um impacto positivo sobre as condições de estabilidade de tensão, e uma diminuição da tensão na barra controlada teve impacto negativo sobre as condições de estabilidade de tensão. Esse é o resultado esperado também quando a ação de controle é adequada. / [en] This research is related to the evaluation of voltage stability conditions of operating points of the power system. It has been studied the modelling of synchronous generators/synchronous compensators and static var compensators. The best models were established with active voltage control and with loss of control. The issue of voltage control was treated through analysis of the matrix sensitivity elements between the controlling variables and voltages at controlled buses. The voltage stability indexes were evaluated. In all cases, control loss proved to have a negative impact on voltage stability conditions. In cases with inadequate control action, results are non-dependent of the opposed relation between the controlling variable and voltage at controlling bus, an increase on voltage at controlled busbar proved to have a positive impact on voltage stability conditions, and a decrease on voltage at controlled busbar proved to have a negative impact on voltage stability conditions. This is also expected when the control action is appropriate.
5

Obtenção da margem minima de estabilidade de tensão de sistemas eletricos de potencia / Computation of voltage stability margins of power systems

Bedoya Bedoya, Duvier Rolando 08 October 2007 (has links)
Orientadores: Carlos Alberto de Castro Junior, Luiz Carlos Pereira da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-08T23:29:31Z (GMT). No. of bitstreams: 1 BedoyaBedoya_DuvierRolando_M.pdf: 801505 bytes, checksum: 8566b9558e25c36e418f2d8d82398e68 (MD5) Previous issue date: 2007 / Resumo: Este trabalho apresenta uma nova e rápida metodologia para calcular a margem mínima de estabilidade de tensão de sistemas de potência. O cálculo da margem de estabilidade de tensão (MET) é normalmente requerido no planejamento e operação dos sistemas de potência. Usualmente, a carga é incrementada em uma direção predefinida baseada em históricos ou previsão da demanda (por exemplo, com fator de potência constante, seguido por um incremento proporcional nos MW da geração) até que o ponto de máximo carregamento (PMC) seja obtido. O cálculo da margem mínima METm, permite obter a pior direção de incremento de carga. Além disso, podem se apresentar situações onde incrementos de carga imprevistos em uma barra ou área conduzam a uma margem menor, arriscando a operação do sistema em modo seguro. O objetivo deste trabalho é apresentar uma metodologia nova e eficiente, do ponto de vista computacional, para obter a METm e a correspondente direção que é equivalente à pior direção de incremento de carga. Esta informação, com a margem que usualmente é calculada, permite que os operadores do sistema tomem medidas preventivas de controle para retornar ou manter o sistema em modo de operação seguro. Adicionalmente, é apresentado um estudo de áreas críticas para identificar as regiões ou barras que mais estão contribuindo a perda de estabilidade de tensão. É possível encontrar a melhor ação de controle, como corte de carga ou compensação reativa / Abstract: This work presents a new and fast method for computing the minimum voltage stability margin of electric power systems. The computation of the voltage stability margin (VSM) is often required for the planning and operation of power systems. Usually, loads are increased along a predefined direction, which can be estimated based on historical data or load forecast (e.g. with constant power factor, followed by a proportional MW generation increase) up to the system's maximum loading point is reached. The computation of the minimum VSM (mVSM) allows obtaining the load increase worst scenario. Also, situations may occur where variations from the predefined load increase direction, as for example, an unexpected load increase at some bus or area, may result in smaller VSM, taking the system to an insecure operating state. The aim of this work is to propose a new and fast method to compute the mVSM? and the corresponding load increase direction for which it occurs. This information, along with the usual VSM, allows operators to take measures like preventive control actions to move the system to securer operating points. Also a general study of critical areas is shown in order to identify the weakest region and bus that are contributing to the loss of voltage stability. It is possible to _nd the best control actions, like load curtailment or reactive compensation / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
6

Logica nebulosa e tecnica de otimização particle swarm aplicados ao controle de tensão e de potencia reativa / Fuzzy logic and particle swarm optimization for reactive power and voltage control

Canoas, Ana Carolina Garcia 16 May 2008 (has links)
Orientador: Carlos Alberto Favarin Murari / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T08:34:49Z (GMT). No. of bitstreams: 1 Canoas_AnaCarolinaGarcia_D.pdf: 790052 bytes, checksum: bdc65cd1e622b5ffa74f95691e03751e (MD5) Previous issue date: 2008 / Resumo: Devido ao crescente aumento da demanda de energia elétrica e ao retardo de investimento na expansão dos sistemas e energia elétrica (SEE), a operação destes sistemas está cada vez mais próxima de seus limites operacionais, contribuindo para maior complexidade dos SEE. Neste sentido, para satisfazer as rígidas condições de operação, um gerenciamento do perfil de tensão e fluxo de potência tem se tornado cada vez mais importante para as concessionárias, de modo a aumentar a segurança operacional dos sistemas e otimizar o uso de fontes de potência reativa, visando suprir aos consumidores energia dentro de determinados padrões de qualidade e confiabilidade. o objetivo principal desta pesquisa é o desenvolvimento de metodologias com o objetivo de monitorar o perfil de tensão, mantendo-o dentro dos limites operativos, visando não perder a qualidade de fornecimento de energia elétrica. O primeiro método trata-se de uma ferramenta de auxílio à tomada de decisão dos operadores nos centros de controle, baseada em um conjunto de regras nebulosas, o qual é a base do sistema de inferência fuzzy (ou nebulosa) que por sua vez se fundamenta na teoria de conjuntos nebulosos. Considerando que o problema de controle de tensão e de potência reativa apresenta características de natureza não-linear e que envolve variáveis de controle contínuas e discretas, foi desenvolvido um segundo método, o qual utiliza lógica nebulosa em conjunto com a técnica de otimização particle swarm. Este método mostra a possibilidade de incorporar lógica nebulosa em algoritmos baseados em busca, possibilitando a redução das perdas do sistema, satisfazendo as restrições de operação, e garantindo que o perfil de tensão mantenha-se dentro dos limites operativos com uma melhor utilização das fontes de potência reativa / Abstract: Due to the growing electrical power demand and the lag of transmission system infrastruc ture, the operation of transmission systems approaches to its limits and increases the complexity of the system operation. ln this context, in order to satisfy the more rigid operating conditions, managing voltage profile and power flow in a more effective way becomes very important to the power companies that have the aim of enhancing the operating conditions and optimiz ing reactive power sources to provide the consumers with an adequate quality and reliability standards. The main objective of this research work is the development of methodologies for monitoring the volt age profile in order to keep it within operating limits and preserving the quality of the energy being served. The first method consists of a tool for helping decision making by system operators in control centres. This method is based on a set of fuzzy rules, which are the base of a fuzzy inference system. Considering that the voltage and reactive power control present nonlinear characteristics and mixed continuous and discrete variables, a hybrid meta-heuristic method based on fuzzy system and particle swarm optimization has been developed. The fuzzy system has been incorporated into swarm intelligence to provide operational point that allows reduction of system losses while satisfies the operationallimits, volt age constraints and the best utilisation of reactive power / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
7

Estudo dos impactos de um sistema fotovoltaico conectado à rede elétrica utilizando análises QSTS / Study of a grid-connected photovoltaic system impacts using QSTS analysis

Bastos, Camila Bianka Silva 27 February 2015 (has links)
Made available in DSpace on 2016-12-12T20:27:38Z (GMT). No. of bitstreams: 1 Camila Bianka Silva Bastos.pdf: 1963598 bytes, checksum: bee88eacc3f6e3c327425297316a691d (MD5) Previous issue date: 2015-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This dissertation presents a study of the operation of two different three-phase grid-connected test-grids with the connection of a 1MWp photovoltaic system. Two analysis methods are used to evaluate the impacts of this photovoltaic systeM, these methods being conventional static analysis and the analysis known as Quasi-Static Time-Series Analysis. Despite the fact that all grids have unique characteristics, it is important to use test-grids, which simulate the real grid characteristics, to analyze the kinds of problems that can occur and then look for alternatives, if necessary. The impacts evaluated are related to the system losses, minimized with the allocation study of the generation on the grid, voltage profile and tap position curve, when automatic load tap changers are used. It was verified that the photovoltaic system interconnection point is the most influenced one after its connection to the grid. The Quasi-Static Time-Series Analysis allow the correct evaluation of the load-generation interaction, running the time series power flow through estimated data for the load and irradiance curves during 168 hours. The conventional static analysis only considers critical operation conditions, like minimum and maximum load, and no generation or maximum generation, and does not evaluate different case scenarios that occur in reality. The photovoltaic systems can bring many advantages to the electric systems, like the improvement on the final consumer voltage profile, line losses reduction, and also environmental impacts reduction. However, with the increase of distributed photovoltaic generation on the electrical grid, it s necessary to be aware of the impacts that this may cause by performing interconnection studies. / Esta dissertação apresenta um estudo da operação de uma rede teste trifásica de média tensão com a interligação de um sistema fotovoltaico de 1,0 MWp. Dois métodos de análise são utilizados para avaliar os impactos deste sistema fotovoltaico, sendo estes métodos as análises estáticas convencionais eas análises conhecidas como Quasi-Static Time-Series Analysis. Apesar de cada rede elétrica apresentar características únicas, é importante a utilização de sistemas testes, que simulam as características de sistemas reais, para analisar que tipos problemas podem surgir e então buscar alternativas, se necessário. Os impactos avaliados se referem às perdas no sistema, minimizadas com a correta alocação da geração, perfil de tensão e curva de posição do tap, no caso de transformador com comutação automática de tap. Contata-se que o ponto de conexão do sistema fotovoltaico é o mais influenciado pela sua conexão à rede. As análises QSTS possibilitam avaliar corretamente a iteração entre carga e geração, efetuando o fluxo de potência consecutivo através de dados estimados para as curvas de carga e de irradiância solar ao longo de 168 horas. Já as análises convencionais consideram apenas condições críticas de operação, como por exemplo, carga leve ou nominal e geração nula ou máxima, não avaliando então diferentes cenários de operação que ocorrem na prática. Os sistemas fotovoltaicos podem trazer muitos benefícios aos sistemas elétricos, como melhoria do perfil de tensão de atendimento ao consumidor, redução de perdas nas linhas, além da redução nos impactos ambientais. Entretanto, com o aumento de geração fotovoltaica distribuída na rede, é necessário estar atento aos impactos que isto pode causar através de estudos de interconexão.