• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 9
  • 9
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

LCA och LCC av olika isoleringsmaterial i en träbaserad väggkonstruktion / LCA and LCC of different thermal insulation materials in a wood-based wall

Fetahagic, Adi, Pantzar, Henrik January 2018 (has links)
Syfte: Syftet med arbetet var att utföra en jämförelse av olika isoleringsmaterial i en träbaserad väggkonstruktion genom LCA och LCC och att sedan skapa ett beslutsunderlag vid val av isoleringsmaterial. Tidigare forskning kring koldioxidutsläpp för olika byggmaterial finns. Däremot är det inte vanligt att dessa studeras tillsammans med ekonomiska aspekter. Målet med arbetet var att genomföra en LCA- och LCC-jämförelse av mineralull och andra typer av isoleringsmaterial i en träbaserad väggkonstruktion och genom resultatet skapa beslutsunderlag vid val av isoleringsmaterial. Detta bryts ner i tre frågeställningar: (1) Vilket isoleringsmaterial ger minst koldioxidbelastning med förutsättningen att tjockleken på isoleringsmaterialet ger samma u-värde i en väggkonstruktion? (2) Vilket isoleringsmaterial har lägst LCC med förutsättningen att tjockleken på isoleringsmaterialet ger samma u-värde i en väggkonstruktion? (3) Hur kan LCA- och LCC-resultat sammanvägas för att skapa beslutsunderlag för val av isoleringsmaterial? Metod: För att besvara ovan nämnda frågeställningar genomförs en litteraturstudie, fallstudie med livscykelanalys och livscykelkostnadsanalys samt dokumentanalys. Resultat: Fyra olika isoleringsmaterial i en träbaserad väggkonstruktion studerades med hänsyn till koldioxidutsläpp och livscykelkostnader. Materialåtgång och u-värde beräknades för väggkonstruktionen. Funktionell enhet för analyserna är 1 kvadratmeter av väggkonstruktionen med ett u-värde på först 0,164 W/m2K och sedan 0,106 W/m2K. Det material som leder till lägst koldioxidutsläpp för väggkonstruktionen är i första hand cellulosa och därefter träfiber, mineralull och sist polyuretan. Det material som leder till lägst kostnader för väggkonstruktionen är i första hand mineralull, cellulosa, träfiber och sist polyuretan. Konsekvenser: Arbetet visar att val av isoleringsmaterial kan sänka koldioxidutsläpp under produktionsfasen utan att medföra höga kostnader. Det visar även att val av isoleringsmaterial blir än mer relevant när energisnåla byggnader ska produceras där u-värde för väggkonstruktionen ligger runt 0,11 W/m2K då detta innebär större isoleringstjocklekar totalt för väggen. För att minska koldioxidutsläpp utan att nämnvärt höja kostnaden bör organiska isoleringsmaterial väljas. Begränsningar: Arbetet behandlar ej klimatpåverkan från husets energi- eller uppvärmningssystem. För att få samma förutsättningar för de valda isoleringsmaterialen måste samma u-värden i väggkonstruktionen uppnås. Arbetet avser hela livscykeln från vagga till grav i en LCA och LCC, dock har utsläpp genererade av transport utelämnats i analyserna. Enbart de termiska och miljömässiga egenskaperna hos isoleringsmaterialen kommer att beaktas. I fallstudien beaktas en träbaserad yttervägg av ett flerbostadshus med trästomme. / Purpose: The aim of this thesis is to perform a comparison of different insulation materials in a wood-based wall structure through LCA and LCC analysis, and then tocreate a decision base for the selection of insulation material. Previous research oncarbon dioxide emissions for various building materials has been done. On the otherhand, it is not common for these to be studied together with economic aspects. The aimof the work is to perform an LCA and LCC comparison of mineral wool and other types of insulation material in a wood-based wall structure and through the result create decision basis in the selection of insulation material. This is investigated by three questions: (1) Which insulation material emits the lowest amount CO2-equivalents, considering that the thickness of the insulation material has the same u-value in a wall structure? (2) Which insulation material leads to lowest LCC, considering that the thickness of the insulation material gives the same u-value in a wall structure? (3) How can LCA and LCC results together create decision bases for choosing insulation materials? Method: In order to answer the above questions a literature study, case study with lifecycle analysis and life cycle cost analysis and document analysis is conducted. Findings: Four different insulation materials in a wood-based wall structure were studied concerning carbon dioxide emissions and life cycle costs. Material utilization and u-value were calculated for the wall structure. Functional unit for the analyses is 1 square meter of the wall structure with a u-value of 0.166 W/m2K and 0.107 W/m2K. The material that leads to the lowest carbon dioxide emissions for the wall structure is cellulose, wood fibre, mineral wool and lastly polyurethane. The material that leads tothe lowest cost of the wall structure is mineral wool, cellulose, wood fibre and lastly polyurethane. Implications: The work shows that the choice of insulation materials can reduce carbondioxide emissions during the production phase without incurring excessive costs. It alsoshows that the choice of insulation materials becomes even more relevant when energy efficient buildings are to be produced where the u-value of the wall structure is around 0.11 W/m2K, as this means larger insulation thicknesses in total for the wall. In orderto reduce CO2 emissions without significantly increasing costs, organic insulation materials should be chosen. Limitations: The work does not address climate impact from the house's energy or heating system. To get the same conditions for the selected insulation materials, thesame u-values in the wall structure must be achieved. The work concerns the entire lifecycle from cradle to grave in an LCA and LCC, however, emissions generated bytransport have been omitted in the analyses. Only the thermal and environmental properties of the insulation materials are treated. The case study considers a wood-based exterior wall of a multi-story building.
2

Anatomical and mechanical features of palm fibrovascular bundles / ヤシ植物繊維維管束の解剖学的ならびに力学的特徴に関する研究

Zhai, Shengcheng 24 September 2013 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(農学) / 甲第17904号 / 農博第2027号 / 新制||農||1018(附属図書館) / 学位論文||H25||N4800(農学部図書室) / 30724 / 京都大学大学院農学研究科森林科学専攻 / (主査)教授 杉山 淳司, 教授 矢野 浩之, 教授 髙部 圭司 / 学位規則第4条第1項該当 / Doctor of Agricultural Science / Kyoto University / DFAM
3

Effect of Floor Slabs and Floor Beams on Static and Dynamic Behaviour of Shear Wall Structures

Biswas, Jayanta K. 11 1900 (has links)
<p>This thesis studies the effect of-floor slabs on the static and dynamic behaviour of the shear wall structure. A single component has been analysed using the 'Matrix Transfer' technique along with Vlaspv's thin walled elastic beam theory. Experimental verification was done on a small scale plexiglas eight storey model in the form of a channel section for both static and dynamic loading. The thesis also deals with the ·analysis of the nonplanar shear walls coupled through floor beams subjected to static loading. The continuum approach along with Vlasov's theory h&s been used in the analysis. Experimental verification was done on a small scale plexiglas model in the form of two equal angles connected by eight floor beams at equal spacing.</p> / Thesis / Master of Engineering (ME)
4

Dynamic Simulation Of Shaking Table Tests For A Shear-wall Building Having Torsion

Nazirzadeh, Saeideh 01 February 2012 (has links) (PDF)
Simulating the non-linear response of reinforced concrete (RC) buildings subjected to a sequence of input earthquake records, is an extremely complex concern in the field of the Earthquake Engineering. Buildings with no symmetry in plan have much more complicated behavior under earthquake effects than symmetric buildings. Torsional irregularity in plan is the main topic of many current researches. In previous decades, considerable amount of numerical and experimental studies have been conducted, but more researches are needed in order to confirm a better understanding of the concept of seismic behavior of these structures. In this study modeling and analyses efforts to simulate the experimental response of a scaled three dimensional reinforced concrete shear wall structure tested on a shaking table, are presented. The model structure is a &frac14 / scale of a three story reinforced concrete building that has torsion due to plan irregularity and layout of structural walls. In order to simulate response quantities measured for the specimen tested on a shaking table, a series of non-linear time history analyses were performed. This structure subjected to AZALEE shaking table tests in Saclay, France under the project of &ldquo / SMART 2008&rdquo / which was led by CEA (Atomic energy agency). The model building was tested under a set of bi-directional synthetic and real ground motions that have varying intensities, peak ground accelerations ranging from 0.1g to 1g. Ground motions were applied sequentially to the specimen, starting with the one having the smallest intensity. Displacements and accelerations measured at different locations on the plan at third story were compared with the numerically computed values in order to check the validity of the Finite Element Model that has been obtained in ANSYS ver.12.1.
5

Polyfunkční dům v Uherském Hradišti / Multifunctional building in Uherské Hradiště

Maňásková, Kristýna January 2014 (has links)
The subject of diploma thesis is the construction of technical project documentation for building realization - Multifunctional building in the town of. The object has three floors with residential attic and basement garage. The land is in the city center Uherské Hradiště and This is a building in the vacant space between existing objects. Construction is rectangular in shape, roofed with a gable roof and is designed from traditional building materials.
6

Beziehung zwischen Struktur und Bruchzähigkeit von Holzzellwänden / Relation between structure and toughness of wood cell walls

Maaß, Mona-Christin 30 June 2020 (has links)
No description available.
7

Collapse Experiments and Assessment of Masonry Wall Buildings

Li, Kai January 2017 (has links)
No description available.
8

Användning av högpresterande betong i husbyggnader : Materialförsök och modellering

Latif Aref, Harzin, Eliassi, Nabaz January 2015 (has links)
Idag är intresset för högpresterande betong (HPB) växande runt om världen då fördelarna är många, eftersom slankare, tätare, starkare och lättare konstruktioner kan tillverkas.   Detta examensarbete handlar om materialförsök och modellering för en typ av HPB som ska användas i husbyggnation. Arbetet inleddes med materialförsök i färskt tillstånd, där god gjutbarhet och konsistens eftersträvades. Utgångspunkten var från ett grundrecept med två olika ballastsorter (slaggballast med flygaska och krossballast från asfaltindustrin med silikastoft), vilka namngavs till pilotförsök 1 och pilotförsök 2. Vidare valdes pilotförsök 1 att provas i hårdnat tillstånd då det visades att det var mer ekonomiskt lönsam eftersom ballasten inte behövde siktas, lägre vct tillhandhölls och att flygaskan som användes i pilotförsök 1 är billigare än silikastoft som användes i pilotförsök 2. Resultaten efter 28 dygn för de materialförsök som utfördes i hårdnat tillstånd var: Tryckhållfasthet; 141,9 MPa Draghållfasthet; 7,0 MPa Böjdraghållfasthet; 10,0 MPa Elasticitetsmodul; 46,4 GPa Krympning efter 56 dygn; 0,5 ‰ Samtliga försök utfördes enligt svenska standarder (SS).   Dessutom vidareutvecklas och förbättrades ett redan arkitektoniskt gestaltat Attefallshus ur ett konstruktions- och hållbarhets perspektiv, där fokus låg på transport- och produktionsförutsättningar. Det resulterade i att horisontella avstyvningar tillades i väggelementen för att öka styvheten och minska risken för brott under transport och produktion. Huset är tänkt att produceras med prefabriceringsteknik. Avslutningsvis modellerades ett oarmerat väggelement i FE-programmet Abaqus under linjärt elastiskt tillstånd. Vid modelleringen användes de materialparametrar som erhölls från materialförsöken.  Det resulterade i att deformationer, spänningar samt knäcknings- och bucklingsanalys kunde redas ut. Väggelementen i huset klarar normenliga laster enligt modelleringen. / Nowadays the interest for high-performance concrete (HPC) is growing around the world as the benefits are many, for example slender, denser, stronger and lighter structures can be manufactured.   This thesis is about material and design experiments for a type of HPC to be used in building construction. The work began with materials experiments in the fresh state, where good workability and consistency were tried to be obtained. The starting point was from a basic recipe with two different aggregate types (slag aggregates with fly ash and crushed aggregates from the asphalt industry with silica fume), which were named as the pilot test 1 and the pilot test 2. Furthermore pilot test 1 was elected to be tested in hardened state as it turned out to be more economically profitable, had a lower vct, and that the flyash was cheaper than the silica fume used in the pilot test 2. The results after 28 days when the materials experiments were carried out in the hardened state were: Compressive strength; 141,9 MPa Tensile strength; 7,0 MPa Flexural strength; 10,0 MPa Modulus of elasticity; 46,4 GPa Shrinkage after 56 days; 0,5 ‰ All experiments were performed according to Swedish standards SS.   Moreover, an existing architecturally portrayed Attefallshus was further developed and improved from a design and a strength perspective that mainly focused on transport and production. It resulted in the horizontal stiffeners to be installed in the wall elements to increase rigidity and reduce the risk of breakage during shipment and production. The house is intended to be built with prefabrication technology. Finally the unreinforced wall elements were modeled in the FE program ABAQUS under linear elastic condition. During modeling the material parameters obtained from material tests were used in the model. Consequently, strain, stress and buckling analysis could be made. The wall sections in the house met the norm loads according to the model.
9

Problem i högt fuktbelastade byggnader : Riskbedömning med hjälp av WUFI / Problems in buildings with high moisture load : Risk assessment using WUFI

Wong, Katilla, Bergh, David January 2012 (has links)
Många av Sveriges badhus byggda i slutet av 1900-talet börjar idag visa tecken på kraftiga fuktskador på grund av extrema inomhusklimat. Denna rapport förklarar den allmänna problematiken kring högt fuktbelastade byggnader och berör det fuktskadade badhuset Aquarena i Katrineholm.  Extrem noggrannhet krävs vid montering av ångspärr i en konstruktion, speciellt vid högt invändigt fukttillskott. Optimal placering av fuktspärren i konstruktionens varmare del innebär att fukt aldrig tillåts kondensera och därmed minimeras risken för fuktskador och negativa konsekvenser. Verkligheten visar också att om kunskaper om fukt och fuktskador prioriteras redan i ett tidigt stadium under projektering kan många hundratusentals kronor sparas. Beräkningar av fukttransport har gjorts för tidigare ytterväggskonstruktion i Aquarena (den som drabbats av skador) och nybyggd ytterväggskonstruktion (nyframtagen till återuppbyggnaden) i datorprogrammet WUFI Pro 4.2 och analyserats i WUFI Bio 3.0.  Beräkningarna visar att den tidigare väggkonstruktionen får de skador som undersökningar av den visat och att skadorna hade kunnat undgås om genomförningar i ångspärren hade utförts på ett korrekt sätt.  Vi har med beräkningar inte kunnat bevisa att alla delar i den nybyggda ytterväggskonstruktionen kommer fungera perfekt. Främst beror osäkerheten i beräkningar utförda i WUFI på att beräkningsmodellen inte är färdigutvecklad. Osäkerheter beror också på otillräcklig kännedom av egenskaper hos de simulerade materialen. Beräkningar för den nyframtagna väggkonstruktionen visar dock entydigt på bättre resultat än för den tidigare väggkonstruktionen. Det finns därför anledning att vidare utreda vilka värden på fukt och temperatur som kommer att råda över de närmaste åren. Detta bland annat för att senare kunna korrigera beräkningsmodellen efter verkligheten. / Many of Sweden's public indoor swimming pools built in the late 1900’s are beginning to show signs of excessive moisture damage due to extreme indoor climate. This report explains the general problem of high moisture-loaded buildings and involves the moisture-damaged public indoor swimming pool Aquarena in Katrineholm. Extreme care is required when assembling the moisture barrier in a structure, especially with high internal moisture content. Optimal placement of the moisture barrier in the warmer parts of the construction means that moisture is never allowed to condense, thus minimizing the risk of moisture damage and negative consequences. Reality also shows that if risks of moisture and moisture damages are assessed early in the planning process, amounts in the range of hundreds of thousands of Swedish crowns can be saved. Calculations of moisture transport have been made for the previous exterior wall structure (the one that suffered damage) and new exterior wall structure the (new design for the reconstruction) using the computer program WUFI Pro 4.2 and analyzed in WUFI Bio 3.0. Calculations show that the old exterior wall structure in Aquarena would have been able to withstand moisture damage and damages due to moisture if joints and transitions in the moisture barrier had been correctly performed.  Calculations have not proven that all elements of the newly built wall design will work perfectly. The main reason for uncertainty in calculations when using WUFI is that the calculation model is not fully developed. Uncertainty is also due to insufficient knowledge of properties of the simulated materials. However, calculations show unambiguously better results than the previous wall construction. It is therefore necessary to further investigate what values of humidity and temperature will exist over the next few years to be able to later on correct the calculation model after reality.

Page generated in 0.0587 seconds