Spelling suggestions: "subject:"zirconia (Y-TZP)""
1 |
Influência do método de aplicação do glaze e de sua associação ao ácido fluorídrico na superfície de uma cerâmica Y-TZPMalta, Natália Veloso 09 June 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-01-13T18:22:43Z
No. of bitstreams: 1
nataliavelosomalta.pdf: 1376730 bytes, checksum: cdeb2bd74c09e4792776e296bd5f7f42 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2017-01-31T10:32:11Z (GMT) No. of bitstreams: 1
nataliavelosomalta.pdf: 1376730 bytes, checksum: cdeb2bd74c09e4792776e296bd5f7f42 (MD5) / Made available in DSpace on 2017-01-31T10:32:11Z (GMT). No. of bitstreams: 1
nataliavelosomalta.pdf: 1376730 bytes, checksum: cdeb2bd74c09e4792776e296bd5f7f42 (MD5)
Previous issue date: 2016-06-09 / O objetivo desse estudo foi avaliar, a influência de duas diferentes técnicas de aplicação de glaze (pincél e spray) sobre a morfologia de superfície de uma cerâmica Y-TZP (IPS e.maxR®ZirCAD (IvoclarVivadent) antes e após a aplicação do ácido fluorídrico. Foram confeccionados 20 corpos de prova a partir de 4 blocos cerâmicos de zircônia parcialmente estabilizada por ítria pré-sinterizados, que foram divididos em 5 grupos (n=4) de acordo com o tratamento de superfície recebido: C= controle (nenhum tratamento de superfície); S: glaze spray VITA AKZENT( Vita Zanhfabrik )P/L: glaze pó/líquido VITA AKZENT (Vita Zanhfabrik,) S+HF: S + condicionamento com ácido fluorídrico 10% (HF)(FGM) (1min); P/L + HF: P/L + condicionamento com HF 10% (1min). As amostras forma então submetidas ao seguintes testes: 1) goniometria, para ánalise do ângulo de contato e da energia de superfície; 2) análise dos dados de rugosidade (Ra) por meio de um perfilômetro óptico digital; 3)identificação das fases cristalinas do material pela Difratometria de Raios X; 4) análise dos elementos químicos presentes no material cerâmico por Microscopia e espectrometria por energia dispersiva (EDS); 5) análise da superfície por meio de microscopia eletrônica de varredura (MEV). Os resultados demonstraram que: 1) a superfície das amostras tratadas com o glaze pó/líquido foram as que apresentaram uma camada mais espessa de glaze, com superfícies menos rugosas; 2)o grupo que recebeu o tratamento com o glaze pó/líquido foi o que apresentou a maior energia de superfície (69,83mN/m), e os demais grupos apresentaram elevados valores de ângulos de contato; 3) o tratamento térmico de vitrificação não causou alterações de fases na estrutura da zircônia; 4)As imagens de perfilometria e MEV revelaram um padrão irregular de disposição do glaze após o condicionamento com HF 10%, e um alto conteúdo de sílica foi observado somente nos grupos P/L e P/L + HF. O estudo concluiu que a utilização do glaze pó/líquido pela técnica do pincel promoveu uma maior padronização da camada de glaze e foi método de tratamento de superfície que apresentou uma maior energia de superfície e um maior conteúdo vítreo. Pelas imagens de microscopia, pode-se observar que a aplicação do ácido fluorídrico a 10% criou microretenções sobre a camada de glaze pó-liquido que podem favorecer a adesão a esta superfície. / The present study evaluated qualitatively the influence of two different types of glaze (brush and spray) on the surface of Y-TZP ceramics (IPS e.maxR® ZirCAD (IvoclarVivadent,) before and after use of hydrofluoric acid. Twenty specimens were made from 4 zirconia ceramic blocks partially stabilized by pre-sintered yttria, which were divided into 5 groups (n=5) according to the surface treatment received: C = Zirconia (control) (no surface treatment); S: glaze spray VITA AKZENT; P/L: glaze powder/liquid VITA AKZENT, S+HF: S + etching with hidrofluoridric acid 10% (HF)(FGM) (1min); P/L + HF: P/L + etching with HF 10% (1min).Samples were then subjected to the following tests: 1) Goniometry for analysis of the contact angle and the surface energy ; 2) Analysis of roughness data (Ra) by means of a digital optical profilometer; 3) Identification of the crystalline phases of the material by X-ray diffraction;4) Analysis of the chemical elements present in the ceramic material by microscopy and energy dispersive spectrometry (EDS); 5) analysis of the surface after each surface treatment by means of scanning electron microscopy (SEM).Partial results showed that: 1) The surface of the samples treated with glaze powder/liquid showed a thicker layer of glaze with less rough surfaces; 2) the group receiving treatment with glaze powder/liquid presented higher surface energy (69,83mN/m), while the other groups showed high values of contact angles; 3) thermal treatment of vitrification did not change the phases of zirconia surface; 4) The SEM and profilometry images revealed a glaze irregular pattern layout after etching with 10% HF, and a high silica content was observed only in GP / L and GP / L + HF groups. The study concluded that use of the glaze powder / liquid by brush technique promoted a greater standardization of the glaze layer and this surface treatment method was the one that showed a higher surface energy and a higher glassy content. For microscopy images, it can be seen that the application of hydrofluoric acid 10% created micro retentions on the glaze powder-liquid layer that can promote adhesion to this surface.
|
2 |
Avaliação da influência de diferentes tratamentos de superfície na resistência de união ao cisalhamento entre zircônia Y-TZP e o cimento resinoso / Influence of different surface treatments on shear bond strength between zirconia Y-TZP and resin cementMaeda, Fernando Akio 12 September 2012 (has links)
OBJETIVOS:1a etapa: validar teste de cisalhamento utilizando um novo dispositivo de padronização através da comparação dos valores de resistência de união (RU) entre a zircônia com dois tratamentos de superfície e um cimento resinoso, aos resultados obtidos com testes de cisalhamento convencional e microcisalhamento; 2a etapa: avaliar o efeito dos primers metálicos à base de MDP por meio da RU entre zircônia Y-TZP e diferentes tipos de cimentos resinosos (de ativação química, duais e auto-adesivo); 3a etapa: avaliar o efeito de dois lasers Nd:YAG e Er:YAG e do jateamento com óxido de alumínio (JAT) na superfície da zircônia Y-TZP antes da sua sinterização final e da abrasão triboquímica mais silano (controle positivo) após a sinterização final, por meio da resistência à flexão (RF), rugosidade superficial (RS) e RU; 4a etapa: avaliar a estabilidade da união entre a zircônia e um cimento resinoso com um primer à base de MDP e de um laser de alta potência após a termociclagem. Os tratamentos superficiais utilizados nesta etapa foram escolhidos com base nos resultados da 2a e 3a etapas. MATERIAL E MÉTODOS: para os testes de RU foram confeccionados corpos de prova de Y-TZP com dimensões 6x6x3mm, e para o teste de RF 2,5x4,5x20 mm. Para 1a etapa os tratamentos de superfície foram JAT+Signum Ziconia Bond (SZB Heraeus), abrasão triboquímica foi realizada Rocatec (ROC 3M Espe), o silano utilizado foi RelyX Ceramic Primer (3M Espe) e os cimentos resinosos: Panavia F (Kuraray), NX3 (Kerr), seT (SDI), Multilink (Ivoclair). Durante a 3a etapa a abrasão triboquímica foi realizada ROC, o laser Nd:YAG (Power Laser ST6, Lares Research - 1,2W, 10 Hz) e Er:YAG (Kavo Key II, KaVo Co. - 120 mJ, 6 Hz). O teste de cisalhamento com dispositivo de padronização foi o método de avaliação da RU utilizado para as 2a, 3a e 4a etapas. Os dados dos testes de RU, RG foram analisados pela ANOVA e Tukey (=0,05) e RF por Kruskall-Wallis (=0,05). RESULTADOS: 1a etapa: pelo teste de microcisalhamento os materiais se comportaram da seguinte forma: JAT+SZB>ROC>CO, sendo que para os outros dois testes de cisalhamento o seguinte ranqueamente foi obtido: JAT+SZB=ROC>CO. 2a etapa: o SZB apresentou maiores valores de RU para todos os cimentos quando comparados aos grupos controle. O ZP aumento os valores para o cimento Panavia F e NX3. Já o AP aumentou os valores para o cimento seT. 3a etapa: para o teste de RU o JAT e Er:YAG resultaram em valores similares ao ROC, sendo que Nd:YAG resultou em maiores valores comparado ao ROC. Quando avaliados por RS: Nd:YAG>Er:YAG>JAT>ROC; já para RF: ROC>JAT=Nd:YAG= Er:YAG. 4a etapa: Após o teste de cisalhamento os seguinte ranqueamento foi obtido: Nd:YAG 24h>Nd:YAG termociclado=SZB 24h>SZB termociclado. CONCLUSÕES: Uma vez que o teste de cisalhamento com dispositivo de padronização mostrou resultados similares ao teste de cisalhamento convencional pode ser um método viável para avaliação da RU. O tratamento com Nd:YAG antes da sinterização final se mostrou efetivo nos valores de RU. / OBJECTIVES: first stage: validate shear test using a new device for standardized by comparing the values of bond strength (BS) with conventional shear test and microshear test, between zirconia and a resin cement with two surface treatments. Second stage: evaluate the effect of metal primers based on MDP by BS between YTZP and different types of resin cements. Third stage: evaluate Y-TZP surface treatments effect of two lasers (Nd:YAG and Er:YAG) and two sandblasting procedures, with Al2O3 (JAT) before final sintering and tribochemical slicatization after the final sintering, through the flexural resistance (FR) surface roughness (SR) and BS. Fourth stage: evaluate the bonding stability between zirconia and resin cement using a MDP-based primer or a high power laser, after thermal cycling. MATERIAL AND METHODS: BS Y-TZP specimens were prepared with dimensions of 6x6x3mm, and for FS test with 2,5x4,5x20 mm. In the first stage the surface treatments of the specimens were JAT+ Signum Ziconia Bond (SZB - Heraeus), tibochemical silicatization using Rocatec (ROC - 3MEspe) and control (CO - without treatment). In the second stage the primers used were Alloy-Primer (AP - Kuraray), SZB, Z-Prime Plus (ZP - Bisco), and the resin cements: Panavia F (Kuraray), NX3 (Kerr), set (SDI), Multilink (Ivoclair). During the third stage the tribochemical silicatization was perfomed using ROC. The shear bond strength device standardized was used to evaluate the BS of second, third and fourth stage. Test data for BS, SR were analyzed by ANOVA and Tukey test ( = 0.05) and FS by Kruskall-Wallis test ( = 0.05). RESULTS: first Stage: the microshear test groups behave as follow: JAT+SZB> ROC>CO, and for the other two shear tests following the ranking were obtained: JAT+SZB=ROC>CO. Second stage: the SZB showed higher BS for all cements when compared to control groups. The ZP values increased for Panavia F and NX3. AP values increased only for the seT cement. Third stage: BS values for JAT and Er:YAG were similar to ROC, and Nd:YAG was higher compared to the ROC. When evaluated by SR: Nd:YAG> Er:YAG>JAT> ROC, while for FS: ROC> JAT = Nd:YAG = Er:YAG. Fourth stage: after the shear test the following ranking was obtained: Nd:YAG 24h> Nd:YAG thermocycled = SZB 24h> SZB thermocycled. CONCLUSIONS: shear bond strength test with standardized device showed similar result to the conventional shear bond strength, and it can be considered a viable method for evaluating the BS. Treatment with Nd:YAG before the final sintering was effective in BS.
|
3 |
Influência do envelhecimento hidrotérmico e da fadiga mecânica na resitência à flexão em cerâmicas de zircônia YTZ-PMota, Yasmine Appes 26 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-02-11T17:37:47Z
No. of bitstreams: 1
yasmineappesmota.pdf: 3142094 bytes, checksum: f48a3614a163468ff68dfebd6bb44c3d (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-02-26T12:05:50Z (GMT) No. of bitstreams: 1
yasmineappesmota.pdf: 3142094 bytes, checksum: f48a3614a163468ff68dfebd6bb44c3d (MD5) / Made available in DSpace on 2016-02-26T12:05:50Z (GMT). No. of bitstreams: 1
yasmineappesmota.pdf: 3142094 bytes, checksum: f48a3614a163468ff68dfebd6bb44c3d (MD5)
Previous issue date: 2014-08-26 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo avaliou a influência do envelhecimento hidrotérmico e da fadiga mecânica sobre a resistência à flexão de cerâmicas de zircônia YTZ-P. Foram confeccionados discos (ISO 6872, diâmetro: 12 mm e espessura: 1,2 mm) a partir de blocos de cerâmicas de zircônia parcialmente estabilizadas por ítria (Emax ZirCAD e ICE Zirkon Translucent) pré-sinterizados. Posteriormente, os discos foram divididos em quatro grupos (n=10) de acordo com o tratamento realizado: 1- controle (sem envelhecimento); 2- ciclagem mecânica (2 x 106 e carga de 200 N); 3- autoclave (134ºC, 24 horas, 2 bar); autoclave (134ºC, 24 horas, 2 bar) mais ciclagem mecânica (2 x 106 e carga de 200 N). Para determinar a quantidade e a profundidade de possíveis transformações de fase da zircônia (te-mo) induzida pela ciclagem mecânica e/ou pela autoclave, foi realizada a análise de difração de Raios X. A microscopia de força atômica foi utilizada para mensurar a rugosidade da superfície das amostras. O tamanho médio dos grãos foi quantificado por meio de microscopia eletrônica de varredura. Em seguida, todas as amostras foram submetidas ao ensaio de resistência à flexão biaxial (ISO 6872) em máquina de ensaio universal (EMIC, V=1 mm/min). Após ensaio de flexão, os dados obtidos (MPa) foram submetidos à Análise de Variância (2 fatores) e ao teste de Tukey (5%). Os resultados demonstraram que os valores de resistência à flexão biaxial das amostras controle Emax ZirCAD e ICE Zirkon foram de 779,961±114,065a MPa e 716,502±185,732a MPa, respectivamente. A ciclagem mecânica não alterou os valores de resistência à flexão das cerâmicas Emax ZirCAD (719,706±130,781a MPa) e ICE Zirkon (743,961±119,150a MPa). Após o envelhecimento em autoclave houve um aumento da resistência à flexão das cerâmicas Emax ZirCAD (848,07±75,859b MPa) e ICE Zirkon (936,47±120,907b MPa). As médias de resistência para os grupos autoclave/ciclagem Emax ZirCAD (867,26±49,301b MPa) e ICE Zirkon (865,51±108,893b MPa) foram semelhantes aos seus respectivos grupos autoclave. Adicionalmente, os grupos autoclave e autoclave mais ciclagem mecânica foram os que exibiram as maiores porcentagens de transformação de fase da zircônia de tetragonal para monoclínica, profundidade de transformação de fase e maiores valores de rugosidade média. O estudo concluiu que a ciclagem mecânica não influenciou significativamente os valores de resistência à flexão das duas cerâmicas estudadas, porém a degradação em baixa temperatura em autoclave aumentou os valores de resistência à flexão biaxial. As duas cerâmicas analisadas exibiram comportamentos semelhantes frente aos tratamentos realizados. / This study evaluated the influence of different aging methods on the biaxial flexural strength in YTZ-P zirconia ceramics. Discs specimes (12 mm, thickness: ISO 6872, diameter 1.2 mm) were made from blocks of partially yttria-stabilized zirconia ceramics (Emax ZirCAD and Zirkonzah) pre sintered. Subsequently, the discs were divided into four groups (n = 10) according to the treatments performed: 1 - control (no aging); 2 - mechanical cycling (2 x 106 and load 200 N); 3 - autoclave (134°C, 24 hours, 2 bar); autoclave (134°C, 24 hours, 2 bar) with mechanical cycling (2 x 106 and 200 N). To determine the percentage and depth of possible zirconia transformations (te-mo) induced by mechanical cycling and/or autoclave, the analysis of X-ray diffraction was performed. The atomic force microscopy was used to measure surface roughness. The average grain size was measured by scanning electron microscopy. After, all specimens were tested for biaxial flexural strength (ISO 6872) in a universal testing machine (EMIC). The data were submitted to statistical tests ANOVA and Tukey (5%). The results showed that values of biaxial flexure strength of control samples Emax ZirCAD and ICE Zirkon were 779.961 ± 114.065a MPa and 716.502 ± 185.732 a MPa, respectively. Mechanical cycling did not altered the values of flexural strength of ceramics Emax ZirCAD (719.706 ± 130.781a MPa) and ICE Zirkon (743.961 ± 119.150 a MPa). After aging in autoclave there was an increase in flexural strength of ceramics Emax ZirCAD (848.07 ± 75.859b MPa) and ICE Zirkon (936.47 ± 120.907 b MPa). The average strengths for the groups autoclave/mechanical cycling ZirCAD Emax (49.301 MPa ± 867.26 b) and ICE Zirkon (108.893 ± 865.51 b MPa) were similar to their respective groups autoclave. Additionally, autoclave and autoclave/mechanical cycling groups exhibited the highest percentages phase transformation of tetragonal to monoclinic, phase transformation depth and higher values of roughness. The study concluded that mechanical cycling did not significantly altered the values of flexural strength of two ceramics studied, but degradation in low temperature in autoclave increased the values of biaxial flexure strength. Both ceramics analyzed exhibited similar behavior to the treatments performed.
|
4 |
Caracterização cristalográfica superficial e da resistência à flexão biaxial de cerâmica Y-TZP translúcida submetida à vários tratamentos de superfícieBittar, Breno Fortes 14 August 2017 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2017-12-20T11:21:00Z
No. of bitstreams: 1
brenofortesbittar.pdf: 2144210 bytes, checksum: e81cc0440d6624e220a83357474498f4 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-12-22T11:56:27Z (GMT) No. of bitstreams: 1
brenofortesbittar.pdf: 2144210 bytes, checksum: e81cc0440d6624e220a83357474498f4 (MD5) / Made available in DSpace on 2017-12-22T11:56:27Z (GMT). No. of bitstreams: 1
brenofortesbittar.pdf: 2144210 bytes, checksum: e81cc0440d6624e220a83357474498f4 (MD5)
Previous issue date: 2017-08-14 / Este estudo avaliou a influência da pigmentação extrínseca na degradação hidrotérmica e resistência à flexão biaxial de cerâmica de zircônia Y-TZP (InCoris TZI – Sirona – EUA) submetidas a diversos tipos de tratamento de superfície. Foram confeccionados discos seguindo a norma ISO 6872 (12x1,2 mm) a partir de blocos de zircônia Y-TZP pré-sinterizados. As amostras foram pigmentadas (InCoris TZI Coloring Liquid A3,5 – Sirona – EUA) pela técnica da imersão por 5 minutos. Foram, então, separadas em grupos de acordo com o critério de se receberam (P), ou não (S), pintura extrínseca (n=60) e posteriormente, de acordo com o tipo de tratamento de superfície a que foram submetidas (n=15): 1 – (C) controle (sem tratamento de superfície); 2 – (R) Rocatec®; 3 – (G) Glazeamento; 4 – (GA) Glazeamento e condicionamento com ácido fluorídrico 10%. Duas amostras adicionais foram, também, analisadas via (1) perfilômetro ótico, para se determinar a influência dos tratamentos de superfície na rugosidade superficial; (2) análise em difração de raio-X (DRX) para se avaliar possíveis transformações de fase; (3) espectrometria por energia dispersiva (EDS) para se avaliar a composição química das amostras; e (4) microscopia eletrônica de varredura (MEV) para caracterização superficial e quantificação do tamanho médio dos grãos. As amostras foram submetidas à ciclagem mecânica (1,2x106, carga de 200N e frequência de 3.8Hz) e ensaio de resistência à flexão biaxial (1mm/min e célula de 1000kg até a fratura catastrófica). A análise dos dados obtidos pela perfilometria permitem afirmar que a pigmentação extrínseca e os tratamentos superficiais empregados alteraram de forma significativa a rugosidade superficial. A análise do DRX permite concluir que o subgrupo SR sofreu alteração de fase T → M (3,5%) e o subgrupo PR apresentou fase cúbica. A análise dos dados permite afirmar que, no grupo S, o tratamento de superfície influenciou de maneira estatisticamente significante a resistência à flexão biaxial (p=0,014), sendo que o subgrupo SR apresentou maior resistência (642,8±112,1 MPa) e o grupo SGF, a menor (542,9±80,96 MPa). O mesmo não ocorre em P, onde não foi observado diferenças estatisticamente significantes (p=0,113). Desta forma, é possível afirmar que a pigmentação extrínseca promove alterações na estrutura do material analisado. / This study evaluated the influence of extrinsic pigmentation on the hydrothermal degradation and biaxial flexural strength of zirconia ceramics Y-TZP (InCoris TZI - Sirona - USA) submitted to several surface treatments. Discs-shape specimens (ISO 6872 - 12x1.2 mm) were prepared from pre-sintered Y-TZP zirconia blocks. The specimens received pigmentation (InCoris TZI Colouring Liquid A3,5 – Sirona – USA) by immersion technique for 5 minutes. Then they were separated into groups according to the criteria of whether they received (P) or not (N), extrinsic pigmentation (n = 60) and then according to the surface treatment they were submitted to (n = 15): 1 - (C) control (as sintered); 2 - (R) Rocatec®; 3 - (G) Glaze; 4 - (GA) Glaze and conditioning with 10% hydrofluoric acid. Two additional samples were also analyzed via (1) optical profilometer to determine the influence of surface treatments on surface roughness; (2) X-ray diffraction (XRD) analysis to evaluate possible phase transformations; (3) dispersive energy spectrometry (EDX) to evaluate the chemical composition of the samples; And (4) scanning electron microscopy (SEM) for surface characterization and quantification of the mean grain size. The samples were submitted to mechanical cycling (1.2x106, 200N load and 3.8Hz) and biaxial flexural strength test (1mm / min and 1000kg cell until catastrophic fracture). The analysis of the data obtained by the profilometer allows to state that the extrinsic pigmentation and the surface treatments employed significantly altered the surface roughness. The XRD analysis allows to conclude that the subgroup SR underwent T → M phase change (3.5%) and the subgroup PR presented also cubic phase. Data analysis allowed us to state that, in the N group, the surface treatment had a statistically significant influence on biaxial flexural strength (p = 0.014), and the SR subgroup presented higher resistance (642.8 ± 112.1 MPa) and the SGF group, the lowest (542.9 ± 80.96 MPa). The same does not occur in P, where no statistically significant differences were observed (p = 0.113). Thus, it is possible to conclude that the extrinsic pigmentation promotes changes in the structure of the analyzed material.
|
5 |
Avaliação da influência de diferentes tratamentos de superfície na resistência de união ao cisalhamento entre zircônia Y-TZP e o cimento resinoso / Influence of different surface treatments on shear bond strength between zirconia Y-TZP and resin cementFernando Akio Maeda 12 September 2012 (has links)
OBJETIVOS:1a etapa: validar teste de cisalhamento utilizando um novo dispositivo de padronização através da comparação dos valores de resistência de união (RU) entre a zircônia com dois tratamentos de superfície e um cimento resinoso, aos resultados obtidos com testes de cisalhamento convencional e microcisalhamento; 2a etapa: avaliar o efeito dos primers metálicos à base de MDP por meio da RU entre zircônia Y-TZP e diferentes tipos de cimentos resinosos (de ativação química, duais e auto-adesivo); 3a etapa: avaliar o efeito de dois lasers Nd:YAG e Er:YAG e do jateamento com óxido de alumínio (JAT) na superfície da zircônia Y-TZP antes da sua sinterização final e da abrasão triboquímica mais silano (controle positivo) após a sinterização final, por meio da resistência à flexão (RF), rugosidade superficial (RS) e RU; 4a etapa: avaliar a estabilidade da união entre a zircônia e um cimento resinoso com um primer à base de MDP e de um laser de alta potência após a termociclagem. Os tratamentos superficiais utilizados nesta etapa foram escolhidos com base nos resultados da 2a e 3a etapas. MATERIAL E MÉTODOS: para os testes de RU foram confeccionados corpos de prova de Y-TZP com dimensões 6x6x3mm, e para o teste de RF 2,5x4,5x20 mm. Para 1a etapa os tratamentos de superfície foram JAT+Signum Ziconia Bond (SZB Heraeus), abrasão triboquímica foi realizada Rocatec (ROC 3M Espe), o silano utilizado foi RelyX Ceramic Primer (3M Espe) e os cimentos resinosos: Panavia F (Kuraray), NX3 (Kerr), seT (SDI), Multilink (Ivoclair). Durante a 3a etapa a abrasão triboquímica foi realizada ROC, o laser Nd:YAG (Power Laser ST6, Lares Research - 1,2W, 10 Hz) e Er:YAG (Kavo Key II, KaVo Co. - 120 mJ, 6 Hz). O teste de cisalhamento com dispositivo de padronização foi o método de avaliação da RU utilizado para as 2a, 3a e 4a etapas. Os dados dos testes de RU, RG foram analisados pela ANOVA e Tukey (=0,05) e RF por Kruskall-Wallis (=0,05). RESULTADOS: 1a etapa: pelo teste de microcisalhamento os materiais se comportaram da seguinte forma: JAT+SZB>ROC>CO, sendo que para os outros dois testes de cisalhamento o seguinte ranqueamente foi obtido: JAT+SZB=ROC>CO. 2a etapa: o SZB apresentou maiores valores de RU para todos os cimentos quando comparados aos grupos controle. O ZP aumento os valores para o cimento Panavia F e NX3. Já o AP aumentou os valores para o cimento seT. 3a etapa: para o teste de RU o JAT e Er:YAG resultaram em valores similares ao ROC, sendo que Nd:YAG resultou em maiores valores comparado ao ROC. Quando avaliados por RS: Nd:YAG>Er:YAG>JAT>ROC; já para RF: ROC>JAT=Nd:YAG= Er:YAG. 4a etapa: Após o teste de cisalhamento os seguinte ranqueamento foi obtido: Nd:YAG 24h>Nd:YAG termociclado=SZB 24h>SZB termociclado. CONCLUSÕES: Uma vez que o teste de cisalhamento com dispositivo de padronização mostrou resultados similares ao teste de cisalhamento convencional pode ser um método viável para avaliação da RU. O tratamento com Nd:YAG antes da sinterização final se mostrou efetivo nos valores de RU. / OBJECTIVES: first stage: validate shear test using a new device for standardized by comparing the values of bond strength (BS) with conventional shear test and microshear test, between zirconia and a resin cement with two surface treatments. Second stage: evaluate the effect of metal primers based on MDP by BS between YTZP and different types of resin cements. Third stage: evaluate Y-TZP surface treatments effect of two lasers (Nd:YAG and Er:YAG) and two sandblasting procedures, with Al2O3 (JAT) before final sintering and tribochemical slicatization after the final sintering, through the flexural resistance (FR) surface roughness (SR) and BS. Fourth stage: evaluate the bonding stability between zirconia and resin cement using a MDP-based primer or a high power laser, after thermal cycling. MATERIAL AND METHODS: BS Y-TZP specimens were prepared with dimensions of 6x6x3mm, and for FS test with 2,5x4,5x20 mm. In the first stage the surface treatments of the specimens were JAT+ Signum Ziconia Bond (SZB - Heraeus), tibochemical silicatization using Rocatec (ROC - 3MEspe) and control (CO - without treatment). In the second stage the primers used were Alloy-Primer (AP - Kuraray), SZB, Z-Prime Plus (ZP - Bisco), and the resin cements: Panavia F (Kuraray), NX3 (Kerr), set (SDI), Multilink (Ivoclair). During the third stage the tribochemical silicatization was perfomed using ROC. The shear bond strength device standardized was used to evaluate the BS of second, third and fourth stage. Test data for BS, SR were analyzed by ANOVA and Tukey test ( = 0.05) and FS by Kruskall-Wallis test ( = 0.05). RESULTS: first Stage: the microshear test groups behave as follow: JAT+SZB> ROC>CO, and for the other two shear tests following the ranking were obtained: JAT+SZB=ROC>CO. Second stage: the SZB showed higher BS for all cements when compared to control groups. The ZP values increased for Panavia F and NX3. AP values increased only for the seT cement. Third stage: BS values for JAT and Er:YAG were similar to ROC, and Nd:YAG was higher compared to the ROC. When evaluated by SR: Nd:YAG> Er:YAG>JAT> ROC, while for FS: ROC> JAT = Nd:YAG = Er:YAG. Fourth stage: after the shear test the following ranking was obtained: Nd:YAG 24h> Nd:YAG thermocycled = SZB 24h> SZB thermocycled. CONCLUSIONS: shear bond strength test with standardized device showed similar result to the conventional shear bond strength, and it can be considered a viable method for evaluating the BS. Treatment with Nd:YAG before the final sintering was effective in BS.
|
6 |
Influência de diferentes tratamentos de superfície sobre a adaptação marginal e resistência de união entre coroas Y-TZP e um material análogo à dentinaAntunes, Monize Carelli Felipe 09 March 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-04T17:19:33Z
No. of bitstreams: 1
monizecarellifelipeantunes.pdf: 3029600 bytes, checksum: 8f67d08272a23a5ae00bcc9865b95fc8 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-07T03:23:14Z (GMT) No. of bitstreams: 1
monizecarellifelipeantunes.pdf: 3029600 bytes, checksum: 8f67d08272a23a5ae00bcc9865b95fc8 (MD5) / Made available in DSpace on 2015-12-07T03:23:14Z (GMT). No. of bitstreams: 1
monizecarellifelipeantunes.pdf: 3029600 bytes, checksum: 8f67d08272a23a5ae00bcc9865b95fc8 (MD5)
Previous issue date: 2015-03-09 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo avaliou o efeito de diferentes tratamentos de superfície na resistência de união e adaptação marginal entre uma coroa de cerâmica Y-TZP e um material análogo à dentina. Foram confeccionadas 40 bases de um material resinoso análogo à dentina (NEMA grade G-10) para originar preparos padronizados. Estes foram usinados para simular um dente preparado para coroa total com término em chanfro, paredes de 6 graus de convergência e anatomia radicular. A porção radicular foi coberta com poliéter (Impregum - 3M ESPE) e incluída em poliuretano (F16 - Axson). Quarenta coroas cerâmicas IPS emax ZirCAD (Ivoclar - Vivadent) foram fabricadas pelo sistema CAD/CAM. Para o tratamento de superfície foram realizadas a silicatização, aplição de primer para zircônia e duas técnicas de vitrificação, sendo que estas representaram os grupos teste. As coroas foram aleatoriamente divididas em 4 grupos (n=10), conforme o tratamento de superfície: GS (Glaze Spray VITA AKZENT), condicionamento com ácido fluorídrico a 10% (HF) (1 min) + silanização (RelyX Ceramic Primer - 3M ESPE); GP (Glaze Pó/Líquido VITA AKZENT), condicionamento com HF a 10% (1 min) + silanização (RelyX Ceramic Primer - 3M ESPE); P: aplicação do primer (Signum Zirconia Bond - Heraeus Kulzer) e RS: jateamento com partículas de óxido de alumínio revestidas por sílica 30 μm (Rocatec Soft® 3M ESPE ) (silicatização) + silanização (RelyX Ceramic Primer - 3M ESPE). Em seguida, realizou-se a cimentação das coroas com o cimento autoadesivo Rely X U200 (3M ESPE), seguindo as recomendações do fabricante. Todas as amostras de cada grupo foram submetidas à ciclagem termomecânica (TC) (2.000.000 ciclos – 100 N, 4 Hz, 5 ºC – 55 ºC, tempo de permanência 60 s), com um pistão de aço inoxidável (Ø=4mm) no centro da superfície oclusal. Para avaliação da desadaptação marginal entre a coroa cimentada e o G-10, realizou-se a análise por estereomicroscópio (EM) (40x), fazendo-se 8 aferições para cada amostra e, por microscópio eletrônico de varredura (MEV). Para determinação da resistência a tração, foi realizado o ensaio mecânico numa máquina de ensaio universal (célula de carga de 1000 Kgf, v= 1mm/min) até o descolamento da coroa. Os dados de desadaptação marginal obtidos foram analisados estatisticamente (Teste Kruskal Wallis e de Dunn: p ˂ 0,05) e os dados de resistência de união foram analisados pelo teste Anova (um fator) e de Tukey (p ˂ 0,05). Os resultados de desadaptação marginal (média e desvio padrão) foram os seguintes GS (48,69±19,90ª μm); GP (65,48±42,57ª μm); P (156,0±113,3c μm) e RS (96,05±62,98b μm). Os resultados de resistência de união foram: GP (470,5±104,1ª μm); GS (416,8±170,2ª μm); P (342,1±109,7ab μm) e RS (208,9±110,0b μm). Através do estudo realizado concluiu-se que os grupos que tiveram menor desadaptação marginal foram GS e GP; os valores de resistência de união dos grupos GP e GS foram estatisticamente superiores aos valores de resistência de união do grupo RS e semelhante aos valores encontrados para grupo P. / This study evaluated the effect of different surface treatments on the bond strength and marginal adaptation from a Y-TZP ceramic crown and a material similar to dentin. Were made 40 bases in a similar resinous material to dentin (NEMA G-10 grade) to give standardized preparations. These were machined to simulate a tooth prepared for full crown in bevel, walls of 6 degrees of convergence and root anatomy. The root portion was covered with polyether (Impregum - 3M ESPE) and included in polyurethane (F16 - Axson). Forty crowns IPS emax ZirCAD (Ivoclar - Vivadent) were fabricated by CAD / CAM system. For the surface treatment were carried out silica coating, application of primer to zirconia and two glazing techniques, and these test groups represented. The crowns were randomly divided into 4 groups (n = 10), as the surface treatment: GS (VITA Akzent Glaze Spray), etching with hydrofluoric acid 10% (HF) (1 min) + silanization (RelyX Ceramic Primer - 3M ESPE ); GP (Glaze Powder / Liquid VITA Akzent), etching with HF 10% (1 min) + silanization (RelyX Ceramic Primer - 3M ESPE); P: primer (Signum Zirconia Bond - Heraeus Kulzer) and RS: sandblasting with aluminum oxide particles coated with silica 30 microns (Rocatec SOFT® 3M ESPE) (silica coating) + silanization (RelyX Ceramic Primer - 3M ESPE). Then was held the cementation of crowns with the self-adhesive cement Rely XU200 (3M ESPE), following the manufacturer's recommendations. All samples from each group were submitted to thermomechanical cycling (TC) (2,000,000 cycles - 100 N, 4 Hz, 5° C - 55° C, residence time 60 sec) with a stainless steel piston (= Ø 4mm) the center of the occlusal surface. Then the analysis by stereomicroscope (MS) (40x) and scanning electron microscope (SEM) to evaluate the marginal leakage between the cemented crown and the G-10 was held. To determine the tensile strength, the mechanical test was performed in a universal testing machine (load cell of 1000 kgf, v = 1 mm / min) until the detachment of the crown. Data marginal misfit obtained were analyzed statistically (Kruskal Wallis and Dunn: p ˂ 0.05) and bond strength data were analyzed by ANOVA (one factor) and Tukey (p ˂ 0.05). The results of marginal leakage (mean and standard deviation) were as follows GS (48.69 ± 19,90ª μm); GP (65.48 ± 42,57ª μm); P (156.0 ± 113,3c μm) and RS (96.05 ± 62,98b μm). The results of bond strength were: GP (470.5 ± 104,1ª μm); GS (416.8 ± 170,2ª μm); P (342.1 ± 109,7ab μm) and RS (208.9 ± 110,0b μm). Through the conducted study showed that the groups that had less marginal discrepancy were GS and GP; values of bond strength of GP and GS groups were statistically superior to the values of bond strength of the RS group and similar to values found for group P.
|
7 |
Efeito de diferentes tratamentos de superfície na resistência de união de um cimento resinoso à zircôniaScaffa, Polliana Mendes Cándia 13 March 2009 (has links)
As ceramicas a base de zirconia (Y-TZP) apresentam propriedades mecanicas superiores as das demais ceramicas odontologicas. Entretanto, o aumento do conteudo cristalino modificou suas caracteristicas de adesao a cimentos resinosos, tornando necessario o desenvolvimento de metodos mais efetivos de uniao a estes materiais. Este trabalho in vitro pretende, portanto, avaliar a influencia de diferentes tratamentos de superficie e de diferentes agentes de uniao na resistencia ao cisalhamento entre uma zirconia estabilizada por itrio e um agente cimentante autoadesivo (RelyX U100®/3M ESPE). Para tal, cilindros de PROCERA® Allzircon receberam como tratamento de superficie jateamento com oxido de aluminio (Al2O3 - 50 m) ou jateamento com o sistema Rocatec. Sobre a superficie tratada dos cilindros foram aplicados, de acordo com os diferentes grupos experimentais, o sistema adesivo Clearfil SE Bond® (Kuraray Co.), e os primers Metal Zirconia Primer (Ivoclar Vivadent) e Alloy Primer (Kuraray Co.) e, finalmente, o cimento resinoso adotado. Cada especime foi, entao, submetido ao teste de cisalhamento (0,05 mm/min), por meio da acao de uma alca de fio ortodontico passando o mais próximo possivel da interface adesiva. A analise de variancia a um criterios (ANOVA) e o teste de Tukey (p<0,05) mostraram que a realizacao do tratamento de superfície aumentou os valores de resistencia de uniao entre a ceramica e o cimento resinoso. O jateamento com o sistema Rocatec (15,33 MPa) apresentou valores significantemente maiores que o jateamento com Al2O3 (11,93 MPa). A aplicacao dos agentes de uniao resultou em uma maior resistencia adesiva, sendo que o sistema adesivo Clearfill SE Bond (17,07 MPa) teve um comportamento estatisticamente superior aos demais materiais. Entre os primers, o Metal Zirconia Primer (11,26 MPa) apresentou maior valor de resistencia de uniao que o Alloy Primer (10,01 MPa). Portanto, a associacao de um tratamento superficial com um agente de união e valida, ja que promoveu os maiores valores de resistencia adesiva. / Yttrium-stabilized tetragonal zircon polycrystal (Y-TZP) ceramics show better mechanical properties than other dental ceramics. However, the high crystalline content modified their adhesiveness to resin cements, making it extremely necessary to develop a more effective adhesive strategy between them. This in vitro study intends to evaluate the influence of different surface treatments and different bond agents on the shear bond strength between a Y-TZP and self-adhesive resin cement. PROCERA® Allzircon cylinders (3.5 mm in diameter) received a surface airborne abrasion treatment with 50 m aluminum-oxide (Al2O3) particles or with the Rocatec system. According to the experimental groups, the adhesive system Clearfil SE Bond® (Kuraray Co.), and the primers Metal Zirconia Primer (Ivoclar Vivadent) and Alloy Primer (Kuraray Co.) were applied on the treated surface of the cylinders, before the application of the adopted resin cement (RelyX U100®/3M ESPE). Each specimen was submitted to the shear bond strength test (0.5 mm/min), by the action of an orthodontic stainless steel ligature wire (0.5 mm in diameter) loop, wrapped around the resin cement, as close as possible to the adhesive interface. One way-ANOVA and Tukey´s post hoc tests (p<0.05) revealed that surface treatment increased bond strength between the ceramic and the resin cement. Silica coating with the Rocatec system (15.33 MPa) showed significantly higher values than airborne abrasion with Al2O3 (11.93 MPa). Application of all bond agents improved shear bond strength: adhesive system Clearfil SE Bond (17.07 MPa) showed better performance than the other evaluated materials, and Metal Zirconia Primer (11.26 MPa) showed higher bond strength values than Alloy Primer (10.01 MPa). Therefore, the association of a surface treatment with a bond agent is suitable, once it resulted in higher values of adhesive strength.
|
8 |
Efeito de diferentes tratamentos de superfície na resistência de união de um cimento resinoso à zircôniaPolliana Mendes Cándia Scaffa 13 March 2009 (has links)
As ceramicas a base de zirconia (Y-TZP) apresentam propriedades mecanicas superiores as das demais ceramicas odontologicas. Entretanto, o aumento do conteudo cristalino modificou suas caracteristicas de adesao a cimentos resinosos, tornando necessario o desenvolvimento de metodos mais efetivos de uniao a estes materiais. Este trabalho in vitro pretende, portanto, avaliar a influencia de diferentes tratamentos de superficie e de diferentes agentes de uniao na resistencia ao cisalhamento entre uma zirconia estabilizada por itrio e um agente cimentante autoadesivo (RelyX U100®/3M ESPE). Para tal, cilindros de PROCERA® Allzircon receberam como tratamento de superficie jateamento com oxido de aluminio (Al2O3 - 50 m) ou jateamento com o sistema Rocatec. Sobre a superficie tratada dos cilindros foram aplicados, de acordo com os diferentes grupos experimentais, o sistema adesivo Clearfil SE Bond® (Kuraray Co.), e os primers Metal Zirconia Primer (Ivoclar Vivadent) e Alloy Primer (Kuraray Co.) e, finalmente, o cimento resinoso adotado. Cada especime foi, entao, submetido ao teste de cisalhamento (0,05 mm/min), por meio da acao de uma alca de fio ortodontico passando o mais próximo possivel da interface adesiva. A analise de variancia a um criterios (ANOVA) e o teste de Tukey (p<0,05) mostraram que a realizacao do tratamento de superfície aumentou os valores de resistencia de uniao entre a ceramica e o cimento resinoso. O jateamento com o sistema Rocatec (15,33 MPa) apresentou valores significantemente maiores que o jateamento com Al2O3 (11,93 MPa). A aplicacao dos agentes de uniao resultou em uma maior resistencia adesiva, sendo que o sistema adesivo Clearfill SE Bond (17,07 MPa) teve um comportamento estatisticamente superior aos demais materiais. Entre os primers, o Metal Zirconia Primer (11,26 MPa) apresentou maior valor de resistencia de uniao que o Alloy Primer (10,01 MPa). Portanto, a associacao de um tratamento superficial com um agente de união e valida, ja que promoveu os maiores valores de resistencia adesiva. / Yttrium-stabilized tetragonal zircon polycrystal (Y-TZP) ceramics show better mechanical properties than other dental ceramics. However, the high crystalline content modified their adhesiveness to resin cements, making it extremely necessary to develop a more effective adhesive strategy between them. This in vitro study intends to evaluate the influence of different surface treatments and different bond agents on the shear bond strength between a Y-TZP and self-adhesive resin cement. PROCERA® Allzircon cylinders (3.5 mm in diameter) received a surface airborne abrasion treatment with 50 m aluminum-oxide (Al2O3) particles or with the Rocatec system. According to the experimental groups, the adhesive system Clearfil SE Bond® (Kuraray Co.), and the primers Metal Zirconia Primer (Ivoclar Vivadent) and Alloy Primer (Kuraray Co.) were applied on the treated surface of the cylinders, before the application of the adopted resin cement (RelyX U100®/3M ESPE). Each specimen was submitted to the shear bond strength test (0.5 mm/min), by the action of an orthodontic stainless steel ligature wire (0.5 mm in diameter) loop, wrapped around the resin cement, as close as possible to the adhesive interface. One way-ANOVA and Tukey´s post hoc tests (p<0.05) revealed that surface treatment increased bond strength between the ceramic and the resin cement. Silica coating with the Rocatec system (15.33 MPa) showed significantly higher values than airborne abrasion with Al2O3 (11.93 MPa). Application of all bond agents improved shear bond strength: adhesive system Clearfil SE Bond (17.07 MPa) showed better performance than the other evaluated materials, and Metal Zirconia Primer (11.26 MPa) showed higher bond strength values than Alloy Primer (10.01 MPa). Therefore, the association of a surface treatment with a bond agent is suitable, once it resulted in higher values of adhesive strength.
|
Page generated in 0.0333 seconds