Spelling suggestions: "subject:" leakage"" "subject:" eakage""
491 |
Análise da capacidade seladora de materiais obturadores endodônticos utilizando a técnica de cromatografia líquida de alta eficiência acoplada à espectrometria de massas / Sealing ability of root canal filling materials by high performance liquid chromatography -tandem mass spectrometryAndré Luiz da Costa Michelotto 02 April 2009 (has links)
O objetivo deste estudo foi avaliar, in vitro, a capacidade seladora de três materiais obturadores endodônticos, com a proposição de uma nova forma de quantificação da infiltração e um novo agente traçador, utilizando um sistema semelhante ao do modelo experimental da glicose. Trinta e seis dentes unirradiculares extraídos tiveram as coroas removidas, permanecendo 12 mm das raízes. Os canais radiculares foram instrumentados e obturados com o sistema Epiphany (GE) ou com a condensação lateral da guta-percha e cimentos AH Plus (GA) ou Sealapex (GS). Com o auxílio de um calcador aquecido removeu-se 7 mm de material obturador. Seis espécimes com os canais completamente obturados tiveram as raízes totalmente impermeabilizadas com duas camadas de esmalte de unhas, constituindo o grupo controle negativo. Os espécimes foram separados em dois grupos para a realização de dois experimentos que diferiram quanto ao modo de adaptação do espécime no sistema (cianoacrilato ou resina epóxi). Uma solução de cafeína (pH 6.0) foi forçada no sentido coronário com uma pressão hidrostática de 2.55 kPa em direção apical. A infiltração foi medida em ng/mL, pela concentração de cafeína na solução receptora do reservatório, em intervalos de 10, 30 e 60 dias. Para a quantificação foi utilizada a cromatografia líquida de alta eficiência acoplada à espectrometria de massas (CLAE-EM/EM). Esta técnica apresentou alta sensibilidade e especificidade na quantificação do agente traçador. Em função da limitação dos agentes de vedação (cianoacrilato e resina epóxi) empregados no modelo experimental, não foi emitida conclusões a respeito da capacidade seladora dos materiais obturadores testados. / The objective of this study was to propose a new way to measure infiltration with a new tracing agent by using a system similar to that of the glucose penetration model. Thirty-six single-root extracted teeth had their root canals filled using the Epiphany system or with a lateral condensation of gutta-percha and AH Plus or Sealapex cement. Two experiments were carried out that used a different mode of adapting the specimen within the system (cyanoacrylate or epoxy resin). A caffeine solution (pH 6.0) was forced in a coronary direction with a hydrostatic pressure of 2.55 kPa towards the tooth apex. The infiltration was measured in ng/mL, by the concentration of caffeine in the receptor solution of the apical reserve at intervals of 10, 30, and 60 days. To quantify the measurements, a high-performance liquid chromatography coupled with mass spectrometry (HPLC-MS/MS) was used. This technique showed a high sensitivity and specificity for quantifying the tracing agent. Due to the limitations of the sealing agents (cyanoacrylate and epoxy resin) used in our experimental model, analysis of the sealing ability of the filling materials tested was not performed. It is necessary to carefully validate the principal variables of the systems that assess infiltration in order to standardize studies and give greater credibility to their results.
|
492 |
Simulação elétrica do efeito de dose total em células de memória estática (SRAM)Paniz, Vitor January 2010 (has links)
Nesta dissertação é apresentado o estudo da célula SRAM estática de 6 transistores, com tecnologia CMOS, sendo utilizada em ambiente exposto à radiação. Foi verificado, através de simulação com o Hspice (HSPICE, 2009; KIME, 1998) e com a análise de Monte Carlo, o seu comportamento com relação à dose de ionização total (Total Ionization Dose, TID), a qual altera a tensão de limiar (threshold voltage, Vth) e a corrente de fuga, não sendo utilizada nenhuma técnica de fabricação especial para tolerância à radiação. Na simulação foi observado o comportamento da célula com relação ao tempo de atraso de escrita, à margem de ruído de leitura e ao consumo de energia. As simulações incluem as tecnologias de 130nm e 350nm sendo, portanto, possível comparar os efeitos de radiação citados em ambas, para verificar qual é a mais naturalmente resistente a radiação, verificando se está coerente com resultados divulgados na literatura. Para simular o efeito de dose, altera-se a tensão de limiar (threshold voltage, Vth) com a análise de Monte Carlo e, para a corrente de fuga, adiciona-se uma fonte de corrente entre o dreno e fonte de cada transistor. Os valores de Vth e corrente de fuga foram obtidos nas referências (HAUGERUD, 2005) para a tecnologia 130nm e (LACOE, 1998) para a tecnologia 350 nm. As simulações mostram que o comportamento foi coerente com resultados já conhecidos, em que a tecnologia mais antiga (350nm) tem alterações mais significativas do que a tecnologia mais atual, em relação à TID. / This work presents the study of the static RAM (SRAM) cell with 6 transistor, using CMOS technology, under radiation environment. The electrical behavior of the cell is evaluated using SPICE simulation (HSPICE, 2009; KIME, 1998) and applying Monte Carlo analysis. The effect of total ionization dose is analyzed through the modeling of threshold voltage shifts and leakage currents. The case study processes of this work do not use any special fabrication steps to make the circuit tolerant to radiation. The behavior of the cell related to write propagation time, read noise margin and energy consumption is evaluated through scripts written to support the simulation campaign. The simulations were performed for both 130nm and 350nm technologies, making possible to compare which one is more resistant to radiation. To further explore the dose effect in the case where the radiation does not affect all transistors in exactly the same way, the threshold voltage (Vth) of the transistors is varied randomly in the Monte Carlo analysis. To consider the leakage current, it is added a current source between drain and source of each transistor. The values of Vth and leakage current were obtained in reference (HAUGERUD, 2005) for the 130nm and in reference (LACOE, 1998) for the 350nm technology. The simulations show that the behavior was consistent with results already known, in which the older technology (350nm) is more significant changes then the most current technology, for the TID.
|
493 |
Análise histológica dos tecidos periapicais de dentes de cães como recurso para avaliar a influência dos auxiliares químicos da instrumentação no selamento dos canais radiculares obturados com RealSeal® e expostos ao meio bucalSantos, Regis Burmeister dos January 2010 (has links)
Este estudo, in vivo, visou a avaliar a influência do auxiliar químico no selamento dos canais radiculares obturados com o sistema RealSeal® e preparados para a colocação de pino protético, pela análise da resposta dos tecidos periapicais de dentes de cães. Foram testados os produtos químicos hipoclorito de sódio a 1% e a clorexidina gel a 2%. A pesquisa foi desenvolvida em 6 cães, 10 dentes em cada um deles, num total de 60 dentes e 120 canais divididos em sete grupos, sendo três grupos teste, três grupos controle negativo e um grupo controle positivo. Todos os dentes permaneceram selados por 24 horas após terem sido tratados. Decorrido este prazo, os selamentos provisórios dos dentes pertencentes aos grupos teste e controle positivo foram removidos, permanecendo sem selamento por 90 dias. Os dentes dos grupos controle negativo foram mantidos com selamento durante todo o período experimental, quando os animais foram mortos e suas mandíbulas removidas. O processamento histológico foi realizado com hematoxilina e eosina. A análise histológica, com auxílio de um microscópio óptico, baseou-se na avaliação da situação histológica dos tecidos periapicais. A análise estatística foi realizada a partir do teste não paramétrico de Kruskal-Wallis com localização de diferenças pelos procedimentos de post-hoc, de Mann-Whitney e Willcoxon. O nível de significância considerado adequado foi de 5%. Os grupos experimentais e controle negativo apresentaram menor grau de inflamação dos tecidos periapicais em comparação com o grupo controle positivo no qual se observou, em todos os espécimes, presença de infiltrado polimorfonuclear neutrófilo e/ou eosinófilo, com presença de áreas de formação de abscesso (p=0,001). Como conseqüência das análises descritas foi concluído que os auxiliares químicos da instrumentação do canal, hipoclorito de sódio a 1%, clorexidina gel a 2% e o soro fisiológico, associados ao EDTA a 17%, não interferiram na resposta do tecido periapical, parecendo, também, não terem interferido na imbricação do sistema RealSeal® nas paredes do canal radicular, no período experimental de 90 dias. Pode-se inferir, ainda, que o material obturador remanescente após o preparo para o pino protético foi eficaz na vedação da zona apical do canal radicular, no espaço do tempo experimental. / The aim of this study was to assess the influence of the cleaning protocol on sealing of root canal obturation with RealSeal following post space preparation, by means of periapical tissue response analysis. 1% sodium hypochlorite and 2% chlorhexidine were the tested products. For this purpose, six dogs were used, 10 teeth in each dog, comprising a total of 60 teeth and 120 root canals, were randomly divided into seven groups, being three test groups, three negative controls and a positive control. Following obturation, all teeth were kept totally sealed during 24 hours to allow sealer setting. Then the positive control and the three test groups had their seal removed, and obturation material exposed to the oral environment for 90 days. Negative controls were kept sealed during the whole experimental period. The animals were killed and their mandibles removed. Histological procedures were adopted as to HE staining. Optical histological analysis at magnifications varying from 25x to 400x considered the periapical tissue status at various sites by a blinded senior observer. Non-parametric Kruskal-Wallis and a Mann-Whitney and Willcoxon post-hoc were adopted at α= 0.05. Experimental groups and negative control had lower degree of inflammation when compared with the positive control, which showed consistently neutrophil and eosinophil infiltrates and areas of abscess (p=0.001). Both sodium hypochlorite and chlorhexidine behaved similarly, not interfering with the periapical tissue response. The remaining filling material was efficient to seal the apical portion of the root canal, regardless of the cleaning protocol.
|
494 |
Detecção de vazamentos em tubulações atraves de metodo acustico e da analise de transientes de pressão / Leak detection in pipelines through acoustic method and pressure transient analysisSousa, Elisangela Orlandi de 27 February 2007 (has links)
Orientador: Sandra Lucia da Cruz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-08T04:57:11Z (GMT). No. of bitstreams: 1
Sousa_ElisangelaOrlandide_M.pdf: 2598884 bytes, checksum: 7421959dcef02a5096290563b5f4500e (MD5)
Previous issue date: 2007 / Resumo: Redes de tubulação são sistemas complexos de dutos utilizados no transporte de fluidos a longas distâncias. Um pequeno vazamento em uma tubulação pode provocar grandes perdas de produtos e sérios danos ao meio ambiente até serem detectados. Com o propósito de prevenir vazamentos em tubulações, várias técnicas são relatadas na literatura. Este trabalho descreve o desenvolvimento e teste de uma técnica de detecção de vazamento de gás em tubulação baseada no método acústico e na análise de transientes de pressão gerados a partir do vazamento. Transientes de pressão e o ruído sonoro gerado pelo vazamento foram detectados e analisados em uma tubulação operando sem e com escoamento contínuo de gás (ar) em várias condições de operação. O trabalho experimental utilizou um vazo de pressão de 34,5 litros e uma tubulação com 60 m de comprimento e ½¿ de diâmetro. A pressão de operação variou de 2 a 7 kgf/cm2. Vazamentos de várias magnitudes foram simulados através de um orifício localizado na tubulação cujo diâmetro variou entre 0,4 mm a 5 mm. O microfone e o transdutor de pressão foram instalados no vaso de pressão ou na tubulação para detectar a ocorrência de vazamento, ambos conectados a um computador PC através de um conversor ADA. O sinal gerado pelo microfone foi amplificado e passou por um banco de filtros passa faixa sendo transformado em três sinais com amplitudes independentes, cada uma com uma faixa de freqüência específica de 1kHz, 5kHz e 9kHz. O programa de aquisição de dados foi escrito em linguagem C para ler e processar os dados. Os resultados experimentais mostraram que é possível detectar vazamentos em tubulações através do método acústico. A análise dos sinais de amplitude para freqüências diferentes mostrou que o ruído sonoro gerado pelo vazamento depende da magnitude do vazamento e da pressão na tubulação. Em todos os experimentos a ocorrência de vazamento foi prontamente detectada pelo microfone enquanto as mudanças nos perfis de transientes de pressão não eram sempre significativas para detectar o vazamento / Abstract: Pipeline networks are complex systems of ducts used in the fluid transportation through long distances. Even small leaks in a pipeline can lead to great losses of product and serious damages to the environment before it could be detected. With the purpose of preventing leakage in pipelines, various techniques have been reported in the literature. This work describes the development and test of a gas leak detection technique in pipelines based on an acoustic method and on the analysis of pressure transients generated by the leak. Pressure transients and the noise generated by leakage have been detected and analysed in a pipeline operating with and without continuous flow of gas (air) under various operation conditions. The experimental setup made use of a 34,5 liters pressure vessel and a 60 m long, ½¿ in diameter pipeline. The operational pressure varied from 2 to 7 kgf/cm². Leakages of various magnitudes were simulated through an orifice located in pipeline whose diameter varied from 0,4 mm to 5,0 mm. A microphone and a pressure transducer were installed either in the pressure vessel or in the pipeline to detect leak occurrence, both being connected to a PC computer through an ADA converter. The signal generated by the microphone was amplified and also passed through a bank of band pass filters being transformed into three signals with independent amplitude, each one with a band of specific frequency of 1 kHz, 5 kHz and 9 kHz. The data acquisition software was written in C language to read and process all data. The experimental results showed that it is possible to detect leaks in pipelines based on acoustic method. The analysis of the signal amplitude for different frequencies showed that the noise signal generated by leakage depend on both leak magnitude and pressure in the pipeline. In all experiments leak occurrence was readily detected by the microphone while the changes in pressure transient profiles were not always significant to detect the leak / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química
|
495 |
Efeito de retenções adicionais na microinfiltração e formação de microfendas na margem gengival de restaurações de classe II extensas, feitas com resina composta: avaliação antes e após ciclagem mecânica / Effect of additional retention in microleakage and gap formation in gingival margin of class II resin restorations: evaluation before and after mechanical cyclingSérgio Kiyoshi Ishikiriama 11 October 2006 (has links)
Este estudo laboratorial comparou a microinfiltração marginal e formação de microfendas em restaurações de classe II extensas, feitas com resina composta com margens situadas em dentina/cemento, utilizando diferentes tipos de retenções adicionais na caixa proximal. Cavidades padronizadas MOD extensas foram confeccionadas em 40 terceiros molares humanos, os quais foram divididos em 4 grupos de acordo com a retenção adicional confeccionada na caixa proximal: (G1) sem retenção adicional - controle; (G2) canaletas verticais nas paredes vestibular e lingual; (G3) orifícios na parede gengival e (G4) canaleta horizontal na parede gengival. Todos os grupos foram restaurados pela técnica incremental, com sistema adesivo (Prime Bond NT - Dentsply) e resina composta híbrida (QuiXfil - Dentsply). Todos os dentes restaurados foram imersos em corante com aplicação simultânea de cargas contínuas (forças variando entre 1kg e 17kg). Moldagens da margem gengival restaurada foram realizadas antes e após a ciclagem mecânica e réplicas de resina epóxica foram obtidas e analisadas em microscópio eletrônica de varredura para avaliação das microfendas marginais. Após as moldagens, todos os dentes foram seccionados para análise da microinfiltração marginal. Todas as micrografias da margem gengival e imagens dos cortes seccionados foram analisados quantitativamente no programa Image Tools (UTHSCSA). Os valores para microinfiltração foram submetidos a análise de variância e teste de Tukey (p< ou = 0,05). As extensões das fendas antes e após a ciclagem mecânica foram comparadas pelo teste \'t\'\' de Student. Também foi realizada uma análise de correlação entre a extensão das microfendas e microinfiltração marginal (teste de correlação de Pearson). Todos os grupos com retenção adicional (G2=11,59, G3=7,11 e G4=1,57) apresentaram microfendas significantemente menos extensas que o grupo controle sem retenção (G1=42,43) (p< ou = 0.05). Resultados similares foram obtidos para a análise de microinfiltração (G1= 82,84; G2=64,73; G3=45,42; G4=3,09), com diferenças significantes entre todos os grupos (p< ou = 0,05). Todos os grupos apresentaram aumento na extensão das fendas após a aplicação de cargas contínuas, com exceção do grupo da canaleta horizontal (grupo 4). Este tipo de retenção adicional apresentou os melhores resultados em ambos os parâmetros. Os resultados mostraram uma tendência a correlação entre os dois parâmetros estudados. Segundo os resultados, as retenções adicionais podem melhorar a adaptação marginal e minimizar a microinfiltração em restaurações de classe II extensas, feitas com resina composta. / This in vitro study compared marginal leakage and gap formation in resin composite class II cavities with gingival margin in cementum, using 3 different additional retention in proximal box. Standardized large MOD cavities, with gingival margins in cementum, were prepared in forty extracted human molars and divided into 4 groups according to the retention in proximal box: (G1) no retention; (G2) vertical grooves in buccal and lingual walls; (G3) pins in gingival wall; and (G4) horizontal grooves in gingival wall. All groups were restored with the incremental technique, using hybrid resin composite (QuiXfil - Dentsply) and bonding agent (Prime Bond NT - Dentsply). All restored teeth were immersed in dye with simultaneous mechanical loading (alternated loading between 1kg and 17kg). Impressions of gingival margins were made before and after mechanical loading and epoxic resin replicas were evaluated in scanning electron microscope for gap formation. After the impressions, all teeth were seccioned for microleakage evaluation. All SEM photomicrographs and seccioned teeth images were analysed with Image Tools (UTHSCSA) software for a quantitative analysis of both parameters. Microleakage data were evaluated by ANOVA and Tukey\'s test. Gap extension before and after mechanical loading were evaluated by Student\'s t test. A correlation analysis was made between gap extension and microleakage (Pearson\'s correlation test). All groups with additional retention (G2=11,59, G3=7,11 e G4=1,57) showed fewer gap formation than control group (G1=42,43) (p< or = 0.05). Similar results were found for microleakage tests (G1= 82,84; G2=64,73; G3=45,42; G4=3,09), with significant differences between all groups (p< or = 0,05). All groups presented an increase in gap extension after loading, with exception to group with gingival retention grooves (G4). This group (G4) showed the best results in both parameters (p< or = 0.05).The results showed a tendency for correlation between the parameters. According the results, additional retention may improve marginal adaptation and minimize leakage in large class II resin composite restorations.
|
496 |
Calibração de modelos de redes de distribuição de água para abastecimento considerando vazamentos e demandas dirigidas pela pressão / Water distribution network calibration model considering leakage and head-driven demandsAlexandre Kepler Soares 27 March 2003 (has links)
No Brasil, são comuns sistemas de distribuição de água para abastecimento com elevados índices de perdas, nos quais parcela significativa das denominadas perdas físicas é devida às perdas por vazamento. Dessa maneira, o controle efetivo das perdas por vazamento e do comportamento do sistema sob as mais diversas condições operacionais é de fundamental importância, não só do ponto de vista financeiro, no que diz respeito ao desperdício da água bombeada e quimicamente tratada, mas principalmente da preservação deste recurso natural. Com o objetivo de se ter um maior conhecimento do comportamento real de uma rede de distribuição de água, técnicas de calibração, incluindo modelos para avaliação de perdas por vazamentos, vêm sendo propostas. Tais modelos devem considerar a relação pressão x vazamento, bem como a dependência pressão x demanda, face aos diferentes níveis de pressão atuantes em um sistema de distribuição de água. O presente estudo visa o desenvolvimento de uma rotina computacional que considere as perdas por vazamento e a dependência das demandas com a pressão, acoplada ao simulador hidráulico EPANET (ROSSMAN, 2000), utilizando dados de rede hipotética com vistas à calibração em termos das rugosidades absolutas, demandas, diâmetros, cotas topográficas e parâmetros do modelo de vazamentos, bem como a localização de componentes hidráulicos na rede. Para tanto, utilizam-se modelos inversos resolvidos com o suporte da tecnologia dos Algoritmos Genéticos (AGs) e procedimento híbrido (AGs e Método Simplex NELDER & MEAD, 1965) / Brazils water distribution systems usually present a high percentage of so-called physical losses, of which a significant portion is caused by leakage. Therefore, it is of fundamental importance, not only from the financial standpoint in terms of the pumped and chemically treated water but also particularly from that of the preservation of this natural resource, to effectively control leakage and the systems behavior under several operational conditions. In order to gain a better understanding of the real behavior of a water distribution network, several calibration techniques, including models to evaluate leakage, have been proposed. Those models normally consider the correlation between pressure and leakage, as well as the interdependence of pressure and demand in response to the varying levels of pressure in a water distribution system. The present study seeks to extend these models through the development of a computational routine based on leakage and on pressure-dependent demand, in conjunction with the hydraulic simulator EPANET (ROSSMAN, 2000), using the data from a hypothetical network to calibrate the absolute roughness and diameter of pipes, demands and elevations of nodes and the parameters of the leakage model, as well as the location of hydraulic components in the network. To this end, inverse models are used based on the technology of Genetic Algorithms (GA) and the hybrid procedure (GA and Simplex Method - NELDER & MEAD, 1965)
|
497 |
Estudo dos parâmetros do decaimento do cloro residual em sistema de distribuição de água tratada considerando vazamento / Study of the residual decay parameters in water distribution systems with leakageSérgio Ricardo Toledo Salgado 15 February 2008 (has links)
O uso do cloro como desinfetante em sistemas de água para abastecimento é prática comum nas estações de tratamento de água. Introduzido durante o processo de tratamento, o cloro participa de diversas reações com compostos de naturezas orgânicos e inorgânicos no interior das tubulações. Tais reações ocorrem na massa líquida e junto às paredes das tubulações e são responsáveis pelo decaimento do cloro ao longo das redes. Visualizando a modelagem como uma ferramenta eficiente para gerenciar o cloro residual em sistemas de distribuição de água, muitos estudos foram realizados e reportados pela literatura, assumindo que os efeitos de decaimento de cloro podem ser bem representados pelos coeficientes kb e kw. Entretanto, a determinação de valores para parâmetros em questão não é uma tarefa fácil, devido à complexidade dos sistemas enfocados em termos da diversidade de materiais das tubulações e mananciais (superficiais e subterrâneos). No Brasil, apesar de legislação recente estabelecer limites restritivos para o cloro na água potável (após desinfecção, a concentração de cloro deve observar a concentração mínima de 0,5 mg/L, sendo o mínimo nível aceito em sistemas de distribuição de 0,2 mg/L e o máximo de 2,0 mg/L), poucos estudos enfocam a avaliação dos parâmetros de decaimento. Esta pesquisa apresenta a aplicação de um modelo inverso elaborado para determinar a ordem para o modelo de decaimento do cloro e os valores globais e/ou locais para o kb e o kw. Sendo programado com o suporte do simulador de EPANET 2 (toolkit) e os algoritmos genéticos como ferramenta de otimização, implementado através da biblioteca de GAlib C++. Os estudos foram realizados em dois sistemas reais da distribuição da água em que foram considerados parâmetros globais e parâmetros específicos da qualidade. Para a investigação da determinação de parâmetros de decaimento de cloro em sistemas de distribuição com vazamento em função da pressão, foi adotada uma rede hipotética com três fontes de cloro. Esse sistema permitiu a calibração e a validação do modelo, assim como a avaliação da influência hidráulica na determinação dos resultados de qualidade de água. / The use of chlorine as disinfectant in water supply systems has been a common practice adopted by the water industry. Introduced during the treatment process, chlorine participates in several reactions with compounds of organic and inorganic nature inside the pipes. Such reactions that occur in the bulk and the wall of the pipes are responsible for chlorine decay along the networks. Visualizing the modeling as an efficient tool to manage the chlorine residual in water distribution systems, many studies have been conducted and reported by the literature, assuming that the chlorine decay effects can be well represented by the decay coefficients kb and kw. However, the determination of values for theses parameters is not an easy task, due to the complexity of the focused systems in terms of pipe materials and water supply sources diversity (surface water and groundwater). In Brazil, instead of recent legislation stating more strict limits for chlorine in drinking water (after disinfection, chlorine concentration has to observe the minimum concentration of 0.5 mg/L, being the minimum accepted level in the distribution system of 0.2 mg/L and the maximum of 2.0 mg/L), few studies focus on the evaluation of the decay parameters. This research reports the application of an inverse model built to determine the order for chlorine decay model and the global and/or local values for kb and kw. It is codified with the support of EPANET 2 (Toolkit) simulator and technology of genetic algorithms as optimization tool, which is implemented by using the GAlib C++ library. The studies were conducted on two real water distribution systems considering both global and specific quality parameters. A hypothetical network with three sources of chlorine was studied too, admitting leakage as pressure function. This system permitted both calibration and validation of the model as well as the evaluation of hydraulic calibration influence on the water quality results.
|
498 |
Microinfiltração coronária em dentes tratados endodonticamente correlacionado ao material restaurador provisório: estudo in vitro / Coronal microleakage in endodontic treated teeth correlated to temporary filling material: an in vitro studyMotta, Magno Linhares da 21 May 2009 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-10T14:17:09Z
No. of bitstreams: 1
magnolinharesdamotta.pdf: 787435 bytes, checksum: f1496aa1318e46521eaae35e86890c8d (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-10-11T15:53:30Z (GMT) No. of bitstreams: 1
magnolinharesdamotta.pdf: 787435 bytes, checksum: f1496aa1318e46521eaae35e86890c8d (MD5) / Made available in DSpace on 2016-10-11T15:53:30Z (GMT). No. of bitstreams: 1
magnolinharesdamotta.pdf: 787435 bytes, checksum: f1496aa1318e46521eaae35e86890c8d (MD5)
Previous issue date: 2009-05-21 / Este trabalho avaliou a microinfiltração marginal em materiais restauradores provisórios utilizados em Endodontia, em diferentes períodos de tempo (3 e 7 dias). Foram utilizados 120 dentes humanos unirradiculares, que após tratamento endodôntico foram separados aleatoriamente em 6 grupos (n=20), de acordo com o material restaurador provisório utilizado: Grupo 1: Vidrion R, Grupo 2: IRM, Grupo 3: Provisory, Grupo 4: Dentalville,, Grupo 5: guta percha e Super Bonder (controle positivo) e Grupo 6: apenas bolinha de algodão (controle negativo). Após a restauração os dentes foram impermeabilizados com esmalte de uso cosmético e submetidos à termociclagem por 500 ciclos (0+/- 5 º C e 55 +/- 5º C). Em seguida foram imersos em solução de azul de metileno 2% por 3 e 7 dias, sendo seccionados longitudinalmente e examinados por lupa estereoscópica com aumento de 40x. Os resultados foram submetidos ao testes estatísticos Mann Whitney e Kruskal Wallis, mostrando resultados significativos quando se utilizou o material Dentalville por um período de 3 dias (p<0,001). Após 7 dias, apenas o grupo 5 (controle positivo) não apresentou microinfiltração marginal, não havendo diferenças estatisticamente significativas entre os demais grupos. Pode-se concluir que o material restaurador provisório Dentalville apresentou menores índices de microinfiltração quando utilizado por um período de 3 dias, comparado aos demais materiais avaliados. / This study evaluated the marginal microleakage in temporary filling materials used in Endodontics, in different time intervals (3 and 7 days). One hundred and twenty uniradicular human teeth comprised the sample of this study. After endodontic treatment they were randomly divided into 6 groups (n=20) according to the temporary restoring material used: Group 1: Vidrion R, Group 2: IRM, Group 3: Provisory, Group 4: Dentalville, Group 5: Gutta percha and Super Bonder (positive control), and Group 6: cotton balls (negative control). After restoration the teeth were were impermeabilized with a nail varnish and submitted to thermocycling with 500 cycles (0+/- 5°C e 55 +/- 5°C). Subsenquently, the teeth were immersed in 2% blue methylene solution for 3 and 7 days, longitudinally sectioned and examined by means of a stereoscopic lens with magnification of 40x. The Mann Whitney and Kruskal Wallis tests were applied for statistical analysis. The results were statistically significant for the Dentalville material at the time interval of 3 days (p<0.001). After 7 days only group 5 (positive control) did not show marginal microleakage, and there was no significant differences between the other groups. It may be concluded that Dentalville temporary restoring material showed the smallest indexes of microleakage at time interval of 3 days when compared to the other materials evaluated.
|
499 |
Avaliação da interação entre as diferentes substâncias químicas auxiliares utilizadas em endodontia e seus efeitos nas etapas do tratamento endodôntico / Evaluation of the interaction among different chemical auxiliary substances used in endodontics and their effects on the steps of endodontic treatmentPrado, Maíra do, 1983- 21 August 2018 (has links)
Orientador: Brenda Paula Figueiredo de Almeida Gomes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T19:11:01Z (GMT). No. of bitstreams: 1
Prado_Mairado_D.pdf: 14853217 bytes, checksum: f86be389a870042c299930884a318e11 (MD5)
Previous issue date: 2012 / Resumo: Introdução: O objetivo do presente trabalho foi avaliar a interação entre as diferentes substâncias químicas auxiliares, utilizadas em endodontia, e seus efeitos nas etapas do tratamento endodôntico. Métodos: Soluções de hipoclorito de sódio (NaOCl) a 0,16%, 1%, 2,5% e 5,25%, clorexidina 2% solução e gel, EDTA 17%, ácido cítrico 10% e ácido fosfórico 37% foram utilizadas isoladamente ou associadas entre si na proporção 1:1. As mesmas foram analisadas quimicamente por espectrometria de massa; e microbiologicamente pelo método de difusão em ágar, contra diferentes patógenos. Adicionalmente, foram avaliados onze protocolos de irrigação em relação à formação de smear layer química por microscopia eletrônica de varredura. Por fim, foram avaliados 9 protocolos de irrigação associados a dois diferentes sistemas de obturação, guta-percha/ AH Plus e Resilon/ Real Seal SE, em relação à microinfiltração coronária e à resistência de união da dentina aos materiais obturadores. Resultados: O NaOCl, em todas as concentrações, associado à clorexidina em ambas as formulações, levou à formação de precipitado, assim como a associação entre a clorexidina e o EDTA e entre clorexidina e solução salina. Todas as associações avaliadas apresentaram algum grau de inibição contra os patógenos testados. Irrigação intermediária, com 10 mL de água destilada, entre as soluções de NaOCl e clorexidina, não foram capazes de inibir a formação de smear layer química, assim como irrigações com EDTA e ácido cítrico. Dos diferentes protocolos de irrigação avaliados, aqueles que apresentaram uma irrigação final com solução de clorexidina 2% tiveram níveis reduzidos de microinfiltração coronária. Em relação à resistência de união à dentina, no sistema obturador guta-percha/AH Plus, os grupos em que se utilizou as associações NaOCl/ácido fosfórico e clorexidina/EDTA apresentaram maiores valores de resistência de união, ao passo que no sistema Resilon/Real Seal SE, os maiores valores foram encontrados nos grupos clorexidina/ácido fosfórico. A utilização da clorexidina como irrigante final não afetou negativamente os sistemas obturadores avaliados. Conclusões: A interação entre as substâncias químicas auxiliares pode levar à formação de precipitados. As diferentes substâncias químicas auxiliares, quando associadas, possuem atividade antimicrobiana. Irrigações intermediárias entre as diferentes substâncias químicas auxiliares são necessárias para reduzir ou até mesmo impedir a formação de precipitados, visualizados na superfície dentinária como uma smear layer química. Durante o preparo químicomecânico, as diferentes substâncias químicas auxiliares geram modificações na superfície dentinária que influenciam na microinfiltração coronária e na resistência de união dos sistemas obturadores guta-percha/AH Plus e Resilon/Real Seal SE / Abstract: Introduction: The aim of the present study was to evaluate the interaction among different chemical auxiliary substances used in endodontics and their effects on different steps of endodontic treatment. Methods: 0.16%, 1%, 2.5% and 5.25% sodium hypochlorite solutions (NaOCl), 2% chlorhexidine solution and gel, 17% EDTA, 10% citric acid, 37% phosphoric acid, distilled water, and saline solution were used both associated with each other (1:1 ratio) and not associated. The solutions were chemically examined with mass spectrometry. They were microbiologically examined using the Agar Diffusion Method, against different pathogens. In addition, eleven protocols were analyzed in regards to chemical smear layer with scanning electron microscopy. Finally, nine irrigation protocols (associated with two filling systems, i.e. gutta-percha/AH Plus and Resilon / Real Seal SE) were examinated regarding coronal microleakage and were examined as well regarding their bond strength with dentin. Results: NaOCl, at all concentrations, associated with both chlorhexidine formulations, led to precipitate formation, similar to the association between chlorhexidine/EDTA, and the chlorhexidine/saline solution association. All associations had some degree of inhibition against the evaluated pathogens. Intermediate flush, with 10 mL of distilled water, between NaOCl and chlorhexidine did not inhibit chemical smear layer formation, similar to intermediate flushes with EDTA and citric acid. Among the different irrigation protocols that were evaluated, when final flush with 2% chlorhexidine was present, the lowest levels of coronal microleakage were found. Regarding the bond strength to dentin, in the gutta-percha/AH Plus system, the groups with NaOCl/phosphoric acid and chlorhexidine/EDTA associations showed higher bond strength values. In the Resilon/Real Seal SE system, the highest values were found in the chlorhexidine/phosphoric acid groups. The use of chlorhexidine as a final flush did not negatively affect the filling systems evaluated. Conclusions: The interaction among the auxiliary chemical substances may lead to precipitate formation. The association between the different substances has antimicrobial activity. Intermediate flushes are necessary to reduce or even avoid the formation of chemical smear layer on the dentin surface. During the chemo-mechanical preparation, the various auxiliary chemical substances used do modify the dentine surface. These modifications have influence in the coronal microleakage and in the bond strength of the filling systems gutta-percha/AH Plus and Resilon / Real Seal SE / Doutorado / Endodontia / Doutora em Clínica Odontológica
|
500 |
Avaliação da influência de métodos de descontaminação após contaminação com sangue em diferentes momentos do processo adesivo / Evaluation of the influence of decontamination methods after contamination with blood in different moments during the dentin adhesive processDamé, Josiane Luzia Dias 23 June 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1
Dissertacao_joziane_luzia_dias_dame.pdf: 564053 bytes, checksum: dd7e96465f7bec29457bc90946463293 (MD5)
Previous issue date: 2006-06-23 / Contamination while restoration procedures are carried out is mentioned in literature as a very frequent event, besides that, there are only a few papers which value this contamination influence in adhesion and possible decontamination methods to be carried out under such an occurrence. So, the aim of this study was to evaluate the influence of decontamination protocols upon dye leakage and push-out bond strength of a dentin adhesive system. It was used a hundred thirty five bovine incisors, which had their labial surface ground to obtain a flat dentine surface where standardized cylindrical cavities were made and they were divided in three groups: A) control without contamination (n = 15); B) contamination prior to the adhesive light activation (Adper Single Bond 2 3M ESPE) (n = 60) and C) contamination after the light activation (n = 60). After the contamination the cavities were divided (n = 15)
according to the protocol used: 1) absorbent paper; 2) water; 3) conditioning with phosphoric acid or 4) sodium hypochlorite at 10%. The cavities were restored with the composite (Filtek Z250 3M ESPE), applied to only one increment. After 24
hours the restorations were polished and the specimens were subjected to thermal cycling (500 cycles/5o C a 55oC/30s). The exposure of the stained margins was done through the use of 2% methylene blue dye (pH = 7.0) and digital measurement of the restorations. The specimens cavity floor was ground, exposing the restoration, and they were submitted to the extrusion test (push out) in a universal testing machine. To statistics analysis it was used ANOVA according to two criteria (moment and protocol) and Tukey s test. In the marginal sealing evaluation there was significant
statistics in the moment factor (p<0.001) and also in the interaction moment x protocol (p<0.008). The percentage average of stained margins found after light activation was statistically higher than the ones found prior to the light activation (p<0.001). In group B the conditioning protocol showed a percentage average of stained margins statistically higher than the water group (p<0.003), and the paper
and hypochlorite groups demonstrated intermediate values. Comparing to group C protocols, it was not detected significant differences. Relating to the extrusion resistance, only the moment factor was statistically significant (p<0.001), while group B values were statistically higher (p<0.05) than the group C ones (5.32+3.03 and 3.4+1.92 MPa respectively). All protocols demonstrated resistance values similar to the control values. Higher resistance values were related to lower values of stained margins. It was concluded that blood contamination after light activation of the adhesive system had an adverse effect in the sealing ability of composite restorations and the different decontamination protocols generally produced similar results / A contaminação durante a realização de procedimentos restauradores é citada na literatura como um evento muito freqüente, apesar disso, poucos são os trabalhos que avaliam a influência desta contaminação na adesão e possíveis métodos de descontaminação a serem realizados frente a sua ocorrência. Assim, este trabalho teve como objetivo avaliar a influência dos métodos de descontaminação no selamento marginal e na resistência à extrusão de um sistema adesivo dentinário. Foram utilizados 135 incisivos bovinos, que tiveram a face vestibular desgastada expondo-se dentina, onde foram confeccionadas cavidades circulares padronizadas.
Estas foram distribuídas em três grupos: A) controle, sem contaminação (n = 15); B) contaminação previamente à fotoativação do adesivo (Adper Single Bond 2 - 3M ESPE) (n = 60) e C) contaminação após a fotoativação (n = 60). Após a
contaminação as cavidades foram divididas (n = 15) de acordo com o método utilizado: 1) papel absorvente; 2) água; 3) condicionamento com ácido fosfórico ou 4) hipoclorito de sódio a 10%. As cavidades foram restauradas com o compósito (Filtek Z250 - 3M ESPE), aplicando-se um único incremento. Após 24h as restaurações foram polidas e os espécimes submetidos à ciclagem térmica (500 ciclos/5°C a 55°C/30s). O selamento marginal foi avaliado utilizando-se o corante azul de
metileno a 2% (pH = 7,0) seguido da digitalização das restaurações. Os espécimes foram desgastados pela face lingual expondo a restauração, e submetidos ao ensaio de extrusão (push out) em uma máquina de ensaios mecânicos. Para a análise estatística foram utilizados ANOVA segundo dois critérios (momento x método) e Teste de Tukey. Na avaliação do selamento marginal houve significância estatística para o fator momento (p<0,001) e também para interação momento X método (p=0,008). O nível médio de margens coradas encontradas após a fotoativação foi estatisticamente superior ao encontrado previamente a fotoativação (p<0,001).
Dentro do Grupo B o método condicionamento demonstrou uma média de margens coradas estatisticamente superior ao grupo água (p<0,003), e os grupos papel e hipoclorito demonstraram valores intermediários. Para as comparações entre métodos dentro do Grupo C não foram detectadas diferenças significativas. Em relação à resistência à extrusão, apenas o fator momento demonstrou ser estatisticamente significante (p<0,001), sendo os valores do Grupo B estatisticamente superiores (p<0,05) aos do Grupo C (5,32±3,03 e 3,4±1,92 MPa respectivamente). Todos os métodos demonstraram valores de resistência similares ao controle. Maiores valores de resistência foram relacionados a menores valores de margens coradas. Concluiu-se que a contaminação com sangue após a fotoativação do sistema adesivo teve um efeito adverso na capacidade de selamento de restaurações de compósito e os diferentes métodos de descontaminação geralmente produziram resultados similares
|
Page generated in 0.0419 seconds