• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 212
  • 150
  • 15
  • 12
  • 12
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 422
  • 111
  • 68
  • 58
  • 44
  • 39
  • 35
  • 34
  • 34
  • 33
  • 32
  • 31
  • 30
  • 27
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Avaliação do osso alógeno fresco congelado para aumento de rebordo mandibular posterior atrófico. Estudo tomográfico em humanos / Evaluation of fresh frozen bone allograft for atrophic posterior mandible augmentation. Tomographic study in humans

Silva, Erick Ricardo 19 January 2016 (has links)
O aumento ósseo de rebordos mandibulares posteriores atróficos continua sendo um grande desafio para os cirurgiões orais. Sabe-se que o osso alógeno pode ser utilizado para realização de enxertos aposicionais nessa região, com bons resultados clínicos e histomorfométricos, porém não há estudos sobre a manutenção óssea volumétrica desses enxertos em longo prazo. O objetivo deste estudo foi avaliar tomograficamente, por meio de medidas lineares e volumétricas, a dinâmica de manutenção do osso alógeno córtico-medular fresco congelado em bloco na cirurgia de aumento ósseo de rebordos mandibulares posteriores atróficos em humanos. Os pacientes do estudo foram submetidos à realização de enxertos aposicionais de osso alógeno fresco congelado em bloco na região posterior mandíbula. Os blocos foram modelados manualmente, fixados aos leitos receptores com parafusos de titânio de 1,5 x 10,0 mm e recobertos com osso mineral bovino e membrana absorvível de colágeno suíno. Para avaliação do ganho ósseo em altura, espessura e volume, cada paciente foi submetido a exames de tomografia computadorizada de feixe cônico (TCFC) em 03 períodos experimentais: imediatamente após a cirurgia de enxerto (T1); 06 meses após a enxertia, no momento de instalação dos implantes (T2) e 01 ano após a carga funcional protética (T3). Os dados obtidos foram tabulados e submetidos à análise estatística por meio do teste de Kruskal-Wallis seguido do post test de Tukey. Para comparação entre dois grupos, foram empregados os testes t de Student e Mann-Whitney. Foram operados 20 pacientes, 15 mulheres e 05 homens, com idade entre 37 e 64 anos (51,8 ± 7,5 anos), para os quais um total de 50 blocos ósseos foi utilizado. Dos 50 blocos, 8% foram utilizados para aumento ósseo em altura, 50% para espessura e 42% para altura e espessura. O ganho ósseo em altura foi de T1 = 5,15 ± 1,04 mm, T2 = 3,91± 0,94 mm e T3 = 2,92 ± 0,71 mm; em espessura, foi de T1 = 6,42 ± 1,20 mm, T2 = 4,64 ± 1,32 mm e T3 = 4,02 ± 0,71 mm. O ganho ósseo em volume foi de T1 = 1176,62 ± 358,08 mm³, T2 = 785,78 ± 201,16 mm³ e T3 = 689,72 ± 187,45 mm³. Foi observada diferença estátistica entre os três tempos experimentais tanto para altura quanto para espessura. Porém, volumetricamente, não foi possível observar diferença entre T2 e T3. No total, foram instalados 50 implantes (01 implante/bloco), para os quais foi obtida uma taxa de sobrevivência de 96% após 31,75 ± 6,99 meses de acompanhamento pós-operatório. Com base nos resultados obtidos, pode-se concluir que o osso alógeno fresco congelado em bloco constitui uma alternativa viável para cirurgia de aumento de rebordo mandibulares posteriores atróficos, apresentando uma manutenção volumétrica aceitável em longo prazo e permitindo a instalação de implantes com alta taxa de sucesso. / Atrophic posterior mandible bone augmentation remains a major challenge for oral surgeons. It is known that allogenic bone can be used for appositional grafts in this region, with good clinical and histomorphometric results, howerer there are no long term studies on the volumetric bone maintenance of these grafts. The objective of this study was to evaluate tomographically, through linear and volumetric measurements, the dynamic maintenance of corticocancellous fresh frozen allograft bone blocks for atrophic posterior mandible augmentation in humans. The patients of the study were submitted to fresh frozen allograft bone block appositional grafting surgery in the posterior mandible. The blocks were manually shaped, fixed to the recipient bed with 1.5 x 10.0 mm titanium screws and covered with bovine bone mineral and porcine collagen absorbable membrane. For assessment of bone gain in height, thickness and volume, each patient underwent cone beam computed tomography (CBCT) at 03 experimental periods: immediately after grafting surgery (T1); 06 months after grafting, at the implant placement (T2) and 01 year after prosthetic functional loading (T3). Data were tabulated and submitted to statistical analysis using the Kruskal-Wallis test followed by Tukey post test. For comparison between two groups, Student t test and Mann-Whitney were employed. Twenty patients were operated, 15 women and 05 men, aged between 37 and 64 years (5.8 ± 7.5 years), for which a total of 50 bone blocks was used. Of the 50 blocks, 8% were used for bone augmentation in height, 50% in thickness and 42% for both height and thickness. The bone gain in height was 5.15 ± 1.04 T1 = mm, T2 = 3.91 ± 0.94 mm and T3 = 2.92 ± 0.71 mm; while in thickness was T1 = 6.42 mm ± 1.20, 4.64 ± T2 = T3 = 1.32 mm and 4.02 ± 0.71 mm. The bone gain in volume was T1 = 1176.62 ± 358.08 mm³, T2 = 785.78 ± 201.16 mm³ and T3 = 689.72 ± 187.45 mm³. Statistical difference was observed between the three experimental times for both height and thickness. However, volumetrically, no difference was observed between T2 and T3. Fifty implants were installed (01 implant/block), with a survival rate of 96% after 31.75 ± 6.99 months of postoperative follow-up. Based on these results, it can be concluded that the fresh-frozen allograft bone block is a viable alternative for atrophic posterior mandible augmentation, presenting an acceptable long-term volumetric bone maintenance and allowing dental implant installation with high success rates.
322

Análise pelo método de elementos finitos de um implante experimental para mandíbulas com reabsorção severa / Finite element analysis of an experimental implant for mandibles with severe resorption

Echevarría, Eduardo Andrés Borie 24 February 2016 (has links)
A reabsorção óssea mandibular severa é um problema, muitas vezes difícil de ser sanado, devido a largura e altura insuficientes de tecido ósseo, tornando impossível o emprego de implantes convencionais sem realizar qualquer tipo de procedimento para aumento ósseo. Várias técnicas para aumento de rebordo alveolar são empregadas, contudo podem apresentar alguns inconvenientes que dificultam o tratamento. Outra alternativa é a utilização de implantes curtos, mas a disponibilidade óssea pode limitar a utilização dos desenhos convencionais atuais. Assim, o objetivo deste estudo foi avaliar pelo método dos elementos finitos a distribuição de cargas em planejamentos com desenho experimental de implantes, em titânio e zircônia, posicionados na região pré foramen mental em mandíbulas com reabsorção severa e diferentes espessuras de cortical externa (1 e 2mm) e próteses totais fixas implantossuportadas. A mandíbula reabsorvida foi modelada com 12mm de altura, considerando o osso trabecular circundado por 2 mm de osso cortical e 1mm de cortical externa. Posteriormente, foi modelado um implante com geometria prismática e posicionado ao nível do osso, um em cada lado, na região interforaminal. Inicialmente, foi realizado um teste preliminar, simulando aplicação de forças axiais e oblíquas com diferentes direções em implantes de titânio e zircônia e osso cortical com 1mm e 2mm de espessura. Após adequação da geometria do implante, foram realizadas as simulações com as próteses confeccionadas em resina acrílica termopolimerizada apoiadas em uma barra com liga à base de Co-Cr. Foi empregada uma carga resultante dos quatro músculos principais da mastigação. Os implantes e pilares de titânio, e a barra protética foram analisados com tensão equivalente Von Mises, enquanto as tensões perimplantares no osso cortical, na região apical do osso trabecular e nos pilares e implantes de zircônia foram analisadas por tensões máximas e mínimas principais. O deslocamento foi fixado em valores mínimo e máximo para comparação do grau de movimentação entre os modelos. A análise foi realizada por meio da visualização gráfica do mapa de cores. O modelo de titânio com 1 mm de espessura de osso cortical apresentou o menor valor (13,27 MPa) de tensão máxima principal no osso, seguido pelo de 2mm (16,22 MPa) e pelos de zircônia de 1mm (16,94 MPa) e 2mm (18,43 MPa). Já os menores valores de tensão mínima foram evidenciados nos modelos com 1mm de osso cortical de titânio (-28,94 MPa) e zircônia (-33,30 MPa). Modelos com implantes de titânio e zircônia apresentaram valores iguais de deslocamento nas espessuras de 1mm (0,15mm) e 2mm (0,19mm). Pelos valores apresentados conclui-se que todos estão dentro nos limiares fisiológicos, com os implantes de titânio propiciando os menores valores de tensão. / Severe mandibular bone resorption is a problem, often difficult to be treated due insufficient width and height of bone tissue, making it impossible to use conventional implants without performing any procedure for bone augmentation. Several techniques for alveolar ridge augmentation are employed, but may present some drawbacks that hinder the treatment. Another alternative is the use of short implants, but the available bone can limit the use of current conventional designs. Thus, the aim of this study was to evaluate through finite element method the load distribution in plannings with an experimental design of implants, in titanium and zirconia, located in the pre-mental foramen region in mandibles with severe resorption and different external cortical thickness (1 and 2 mm) and complete implant-supported fixed dentures. The resorbed jaw was modeled with 12mm in height, considering the trabecular bone surrounded by an external cortical bone of 2 and 1mm. Subsequently, was modeled an implant with prismatic geometry and located at bone level, one on each side, between the mental foramen region. Initially, a preliminary test was performed simulating the application of axial and oblique forces with different directions over titanium and zirconia implants and with cortical bone thickness of 1mm and 2mm. After adjustment of implant geometry, analyses with prostheses made of heat-polymerized acrylic resin and supported on a Co-Cr framework were performed. It was employed a resultant load of the main four chewing muscles. The titanium implants and abutments and framework were analyzed through equivalent Von Mises stresses, while the stresses in the periimplant cortical bone, at apical region of the trabecular bone and the zirconia implants and abutments were analyzed through maximum and minimum principal stresses. Total deformation was set at minimum and maximum values to compare the degree of movement between the models. The analysis was performed through the graphical visualization of the color map. The model in titanium with 1mm-thick of cortical bone showed the lowest maximum principal stress value (13.27 MPa) at bone, followed by the 2mm-thickness (16.22 MPa) and the zirconia of 1 mm (16.94 MPa) and 2 mm (18.43 MPa). The lowest minimum stress values were observed in models with 1 mm of cortical bone in titanium (-28.94 MPa) and zirconia implants (- 33.30 MPa). Models with titanium and zirconia implants had equal total deformation values in thicknesses of 1mm (0.15 mm) and 2 mm (0.19 mm). By the observed values it may conclude that all models were within the physiological limits, with titanium implants providing the lowest stress values.
323

Comparação da anatomia transversal de mandíbula de indivíduos classe III com e sem fissura labiopalatina por meio de tomografia de feixe cônico / Comparison of transverse dimension of class III mandible with and without cleft lip and palate using conical beam tomography

Mello, Marina de Almeida Barbosa 22 March 2017 (has links)
A relação entre a anatomia mandibular e a ocorrência de fratura indesejada de mandíbula na osteotomia sagital é alvo de estudos. A literatura mostra a existência de diferentes conformações anatômicas da mandíbula, porém não há estudos nessa área direcionados a indivíduos com fissura labiopalatina. Também não há na literatura estudos que mostrem as diferenças morfológicas da mandíbula relacionadas a secção transversal entre primeiro e segundo molar e sua relação com implicações na cirurgia ortognática. O objetivo do presente estudo foi avaliar a morfologia da região entre primeiro e segundo molar inferior e classificar a prevalência dos tipos mandibulares dentro de cada grupo. Foram realizadas análises e medições das reformatações das tomografias da região de molares, bilateralmente, de indivíduos Classe III, com fissura labiopalatina unilateral (Grupo FLP) submetidos à cirurgia ortognática para recuo mandibular no Hospital de Reabilitação de Anomalias Craniofaciais e de indivíduos Classe III, sem fissura (Grupo Controle) do banco de dados do Departamento de Cirurgia e Estomatologia da Faculdade de Odontologia de Bauru. Foram realizadas duas medidas lineares e uma medida angular. As hemimandíbulas foram classificadas segundo a profundidade da fossa mandibular em: Tipo a - 0 e 1mm; Tipo b - 1,1 e 2mm; Tipo c - 2,1 e 3mm; Tipo d - maior que 3,1mm. Foram analisadas 200 hemimandíbulas no Grupo FLP e 100 no Grupo Controle. Os resultados mostraram que não houve diferença entre os grupos quanto a classificação das mandíbulas segunda a profundidade da fossa, sendo o grupo b o mais prevalente, mas houve diferença em relação a angulação e a altura da mandíbula . Também foi notada uma relação entre a altura da mandíbula e a sua angulação em ambos os grupos. Assim, pode ser observada a grande variação morfológica dessa região, tanto para o grupo com fissura labiopalatina, quanto para o grupo controle. / The relationship between a mandibular anatomy and an occurrence of an undesirable jaw fracture in a sagittal osteotomy is the subject of the studies. The literature shows an existence of different anatomical conformations of the mandible, but there are no studies on the area directed to individuals with cleft lip and palate. There are not in the literature, studies that show a prevalence of mandibular types and the relation of these anatomical variations with orthognathic surgery implications. The objective of the present study was evaluate the morphology of the region between the first and second lower molars and analyze the prevalence of mandibular types within each sample group. Analyzes and measurements of the CT scans were performed bilaterally on Class III patients with unilateral cleft lip and palate (CLP Group) submitted to orthognathic surgery for mandibular retreatment at the Hospital for Rehabilitation of Craniofacial Anomalies and Class III individuals, without Fissure (Control Group) of the database of the Department of Stomatology of the Faculty of Dentistry of Bauru. Two linear measurements and one angular measurement were performed. The half of mandibles were classified according to the depth of the mandibular fossa in: Type a - 0 and 1mm; Type b - 1.1 and 2mm; Type c - 2.1 and 3 mm; Type d - greater than 3.1mm. Two hundred half of mandibles were analyzed in the CLP Group and 100 in the Control Group. The results showed that there was no difference between the groups regarding the classification of the mandibles according to the depth of the fossa, being group b the most prevalent, but there was difference in relation to the angulation and the height of the mandible. It was also noted a relationship between the height of the mandible and its angulation in both groups. Thus, the great anatomical variation of this region can be observed, both for the group with fissure and for the group without fissure.
324

Análise pelo método de elementos finitos de um implante experimental para mandíbulas com reabsorção severa / Finite element analysis of an experimental implant for mandibles with severe resorption

Eduardo Andrés Borie Echevarría 24 February 2016 (has links)
A reabsorção óssea mandibular severa é um problema, muitas vezes difícil de ser sanado, devido a largura e altura insuficientes de tecido ósseo, tornando impossível o emprego de implantes convencionais sem realizar qualquer tipo de procedimento para aumento ósseo. Várias técnicas para aumento de rebordo alveolar são empregadas, contudo podem apresentar alguns inconvenientes que dificultam o tratamento. Outra alternativa é a utilização de implantes curtos, mas a disponibilidade óssea pode limitar a utilização dos desenhos convencionais atuais. Assim, o objetivo deste estudo foi avaliar pelo método dos elementos finitos a distribuição de cargas em planejamentos com desenho experimental de implantes, em titânio e zircônia, posicionados na região pré foramen mental em mandíbulas com reabsorção severa e diferentes espessuras de cortical externa (1 e 2mm) e próteses totais fixas implantossuportadas. A mandíbula reabsorvida foi modelada com 12mm de altura, considerando o osso trabecular circundado por 2 mm de osso cortical e 1mm de cortical externa. Posteriormente, foi modelado um implante com geometria prismática e posicionado ao nível do osso, um em cada lado, na região interforaminal. Inicialmente, foi realizado um teste preliminar, simulando aplicação de forças axiais e oblíquas com diferentes direções em implantes de titânio e zircônia e osso cortical com 1mm e 2mm de espessura. Após adequação da geometria do implante, foram realizadas as simulações com as próteses confeccionadas em resina acrílica termopolimerizada apoiadas em uma barra com liga à base de Co-Cr. Foi empregada uma carga resultante dos quatro músculos principais da mastigação. Os implantes e pilares de titânio, e a barra protética foram analisados com tensão equivalente Von Mises, enquanto as tensões perimplantares no osso cortical, na região apical do osso trabecular e nos pilares e implantes de zircônia foram analisadas por tensões máximas e mínimas principais. O deslocamento foi fixado em valores mínimo e máximo para comparação do grau de movimentação entre os modelos. A análise foi realizada por meio da visualização gráfica do mapa de cores. O modelo de titânio com 1 mm de espessura de osso cortical apresentou o menor valor (13,27 MPa) de tensão máxima principal no osso, seguido pelo de 2mm (16,22 MPa) e pelos de zircônia de 1mm (16,94 MPa) e 2mm (18,43 MPa). Já os menores valores de tensão mínima foram evidenciados nos modelos com 1mm de osso cortical de titânio (-28,94 MPa) e zircônia (-33,30 MPa). Modelos com implantes de titânio e zircônia apresentaram valores iguais de deslocamento nas espessuras de 1mm (0,15mm) e 2mm (0,19mm). Pelos valores apresentados conclui-se que todos estão dentro nos limiares fisiológicos, com os implantes de titânio propiciando os menores valores de tensão. / Severe mandibular bone resorption is a problem, often difficult to be treated due insufficient width and height of bone tissue, making it impossible to use conventional implants without performing any procedure for bone augmentation. Several techniques for alveolar ridge augmentation are employed, but may present some drawbacks that hinder the treatment. Another alternative is the use of short implants, but the available bone can limit the use of current conventional designs. Thus, the aim of this study was to evaluate through finite element method the load distribution in plannings with an experimental design of implants, in titanium and zirconia, located in the pre-mental foramen region in mandibles with severe resorption and different external cortical thickness (1 and 2 mm) and complete implant-supported fixed dentures. The resorbed jaw was modeled with 12mm in height, considering the trabecular bone surrounded by an external cortical bone of 2 and 1mm. Subsequently, was modeled an implant with prismatic geometry and located at bone level, one on each side, between the mental foramen region. Initially, a preliminary test was performed simulating the application of axial and oblique forces with different directions over titanium and zirconia implants and with cortical bone thickness of 1mm and 2mm. After adjustment of implant geometry, analyses with prostheses made of heat-polymerized acrylic resin and supported on a Co-Cr framework were performed. It was employed a resultant load of the main four chewing muscles. The titanium implants and abutments and framework were analyzed through equivalent Von Mises stresses, while the stresses in the periimplant cortical bone, at apical region of the trabecular bone and the zirconia implants and abutments were analyzed through maximum and minimum principal stresses. Total deformation was set at minimum and maximum values to compare the degree of movement between the models. The analysis was performed through the graphical visualization of the color map. The model in titanium with 1mm-thick of cortical bone showed the lowest maximum principal stress value (13.27 MPa) at bone, followed by the 2mm-thickness (16.22 MPa) and the zirconia of 1 mm (16.94 MPa) and 2 mm (18.43 MPa). The lowest minimum stress values were observed in models with 1 mm of cortical bone in titanium (-28.94 MPa) and zirconia implants (- 33.30 MPa). Models with titanium and zirconia implants had equal total deformation values in thicknesses of 1mm (0.15 mm) and 2 mm (0.19 mm). By the observed values it may conclude that all models were within the physiological limits, with titanium implants providing the lowest stress values.
325

Estudo biomecânico comparativo de sistemas de fixação de 2,0-mm locking e convencionais em fraturas de ângulo em mandíbulas de cordeiro sob esforços em três eixos no espaço / Comparative biomechanical study of locking and conventional 2,0-mm fixation systems on angle fractures in sheep\'s mandibles under stresses on three axes in space

Saavedra, Milton de Siqueira Ferreira Anzaloni 23 February 2017 (has links)
O objetivo deste trabalho foi avaliar comparativamente a rigidez vertical, horizontal e de resistência à ruptura, com liberdade de movimentos em três eixos no espaço, de mandíbulas fixadas com sistemas 2,0-mm locking e convencionais com uma ou duas placas, em fraturas unilaterais no ângulo mandibular. Vinte mandíbulas de cordeiro, submetidas a osteotomia reproduzindo fraturas, foram divididas em três grupos: F1PC - placa convencional em linha oblíqua; F2PC - duas placas convencionais de modo monoplanar; FL - placa de sistema locking 2,0mm em linha oblíqua. Foi utilizada máquina de ensaio universal, onde foi acoplado suporte metálico com rodas para as mandíbulas. O sistema foi analisado em três diferentes momentos: pré-osteotomia com mandíbulas hígidas e pós-osteotomia/fixação e resistência à ruptura. Os valores de rigidez foram submetidos a análise de variância (p<0,005). Os valores de rigidez vertical (p< 0,0001), horizontal (p= 0,0005) e resistência a ruptura (p= 0,0001) entre pré e pósosteotomia/ fixação apresentaram uma diminuição significante. Na comparação entre os grupos, houve diferença significante para a rigidez vertical (p= 0,009) e o grupo F2PC apresentou maior rigidez. Na comparação entre os grupos, não houve diferença significante para a rigidez horizontal e para resistência a ruptura. Foi concluído que para rigidez vertical, horizontal e resistência a ruptura os valores de pós-osteotomia/fixação foram significantemente menores, o sistema de fixação com duas placas convencionais mostrou maior resistência quanto à rigidez vertical que os demais sistemas e não houve diferença estatisticamente significante na comparação entre os grupos quanto a rigidez horizontal e resistência a ruptura. / The objective of this work was to evaluate the vertical, horizontal and tensile rigidity with freedom of movement in three axes in space, of mandibles fixed with 2.0-mm locking and conventional systems with one or two plates, in unilateral fractures in the Angle of the mandible. Twenty mandibles of lamb, submitted to osteotomy and reproducing fractures, were divided into three groups: F1PC - conventional oblique line; F2PC - two conventional single-mode boards; FL - 2.0mm locking system plate in oblique line. A universal test machine was used, where metal support was coupled with wheels for the jaws. The system was analyzed in three different moments: pre-osteotomy with healthy mandibles and post-osteotomy / fixation and resistance to rupture. The stiffness values were submitted to analysis of variance (p <0.005). The values of vertical rigidity (p <0.0001), horizontal (p = 0.0005) and resistance to rupture (p = 0.0001) between pre and post osteotomy / fixation showed a significant decrease. In the comparison between the groups, there was a significant difference for vertical stiffness (p = 0.009) and the F2PC group presented greater stiffness. In the comparison between the groups, there was no significant difference for horizontal rigidity and for resistance to rupture. It was concluded that for post-osteotomy / fixation values were significantly lower for vertical, horizontal and tensile rigidity, the fixation system with two conventional plates showed greater resistance to vertical rigidity than the other systems and there was no statistically significant difference in comparison between the groups for horizontal rigidity and resistance to rupture.
326

Microarchitecture osseuse et adiposité médullaire de la mandibule : étude expérimentale chez la ratte adulte ovariectomisée / Bone microstructure and bone marrow adiposity in the mandible : experimental study in the adult ovariectomiezed rat model

Coutel, Xavier 19 November 2018 (has links)
L’ostéoporose est une maladie fréquente et généralisée du squelette qui se caractérise par une perte de masse osseuse et des altérations de la structure des os. Ces variations des propriétés osseuses, observées à diverses échelles et associées à une augmentation du contenu adipeux de la moelle, témoignent d’une plus grande fragilité du squelette. Ces modifications sont cependant différentes en fonction du site. Cette variation du contenu adipeux médullaire, rapportée notamment dans les os longs du squelette appendiculaire, semble jouer un rôle crucial dans la survenue de l’ostéoporose. Néanmoins, ces altérations ostéo-médullaires, aussi bien quantitatives que qualitatives, sont controversées et peu documentées au niveau des maxillaires, la mandibule en particulier. Le but de notre étude est d’évaluer, au cours du vieillissement et dans un modèle d’ostéoporose (ratte adulte ovariectomisée), les relations entre les variations du contenu adipeux médullaire et la microarchitecture osseuse en site mandibulaire en comparaison avec un site de référence, le tibia. La microarchitecture osseuse, la quantité et la répartition du contenu adipeux médullaire après marquage au tétroxyde d’osmium ont été analysées par microtomographie à rayons X dans la mandibule dentée (os alvéolaire) et non dentée (condyle). Au cours du vieillissement, aucune altération des paramètres osseux et médullaires n’a été mise en évidence. En revanche, le déficit hormonal en oestrogènes induit par ovariectomie conduit à une perte osseuse plus marquée (+35%) dans le tibia que dans la mandibule, associée à des modifications microarchitecturales et adipeuses médullaires site-spécifiques. En effet, en comparaison avec le tibia, un faible contenu adipeux (<10% de moelle) est retrouvé dans le secteur denté (alvéolaire) ainsi que non denté (condyle). A la différence du tibia, au sein duquel un effet de « clustering » des adipocytes est observé à la surface osseuse trabéculaire, le contenu adipeux mandibulaire est réparti de manière homogène dans les espaces médullaires avec très peu de contact avec la surface osseuse trabéculaire. En conclusion, nos résultats indiquent une perte osseuse modérée dans la mandibule par rapport au tibia associée à une augmentation du contenu adipeux médullaire tardive dont la répartition au sein des espaces médullaires n’est pas modifiée à la différence du tibia. Nous émettons l’hypothèse qu’une activité de remodelage et des sollicitations biomécaniques différentes puissent expliquer les spécificités physiopathologiques observées en site mandibulaire. D’autres études seront nécessaires pour préciser l’impact de telles modifications sur la qualité osseuse à l’échelle moléculaire et élémentaire, ainsi que pour préciser les mécanismes de dialogues entre les ostéoblastes et les adipocytes. / Osteoporosis is a common disease of the skeleton characterized by a loss of bone mass and changes in bone structure. These variations in bone properties, observed at various scales and associated with an increase in the bone marrow adipose tissue (BMAT) content, indicate a greater fragility of the skeleton in a site-specific manner. This variation in the BMAT content, reported in some skeletal sites, seems to play a crucial role in the occurrence of osteoporosis. Nevertheless, these bone and marrow alterations, both quantitative and qualitative, are controversial and still poorly documented in the jaw bones, the mandible in particular.The aim of our study was to investigate, during aging and in a rodent model of osteoporosis (adult ovariectomized rat), the relationships between the changes in the bone microstructure, the marrow fat content and its distribution in the mandibular site in comparison with a reference site, the tibia. The bone microstructure, the bone marrow fat content and its distribution after osmium tetroxide staining were analyzed by a specific X-ray microfocus tomography approach in the mandible in the teeth-bearing area (alveolar bone) and in the condyle. During aging, neither bone nor bone marrow alterations have been observed. In contrast, estrogen deficiency did lead to more important bone loss (+35%) in the tibia than in the mandible associated with site-specific microstructural and BMAT modifications. Indeed, in comparison with the tibia, a low BMAT content (<10% of marrow volume) was found in the alveolar bone as well as in the condyle. Compared to tibia which reveals a clustering of the marrow adipocytes at the trabecular bone surface, the mandibular BMAT content was homogeneously distributed and located further away with almost no contact with the trabecular bone surface. In conclusion, our results indicate a moderate bone loss in the mandible compared to the tibia associated with an increase in the BMAT content whose distribution within the marrow spaces is not modified in contrast to tibia. We hypothesize that a differential bone turn-over rate, biomechanical stress may explain in part the mandibular physiopathological specificities reported. Further studies will be needed to precise the impact of such alterations on bone quality at the molecular and elemental level, as well as to depict the mechanisms of dialog between osteoblasts and adipocytes.
327

Análise morfológica da cabeça da mandíbula por tomografia computadorizada de feixe cônico em Indivíduos jovens com ou sem Síndrome de Down

Pereira, Alexandre Miranda 25 March 2013 (has links)
Submitted by Fabíola Silva (fabiola.silva@famerp.br) on 2016-07-26T15:07:30Z No. of bitstreams: 1 alexandremirandapereira_dissert.pdf: 2691507 bytes, checksum: 59310c2c32ff23d4dc858c5d7bf68dd8 (MD5) / Made available in DSpace on 2016-07-26T15:07:30Z (GMT). No. of bitstreams: 1 alexandremirandapereira_dissert.pdf: 2691507 bytes, checksum: 59310c2c32ff23d4dc858c5d7bf68dd8 (MD5) Previous issue date: 2013-03-25 / The Tempormandibular joint (TMJ) is considered to be the most complex of the human body. It is classified as synovial, and then presents capsule and articular disc, membrane, synovial fluid and ligaments. Particularly, TMJ is a form of connection between the mandibular condyle (face) and temporal bone (skull), which generates a mechanically stable joint component. There are currently few studies concerning the study of TMJ in patients with Down syndrome (DS) (trisomy 21). The aim of this study is to morphologically analyze the mandibular condyle by means of Cone Beam Computed Tomography (CBCT) in young individuals with or without SD. After ethical approval, 23 patients were allocated (male or female and aged between 18 and 20 years), 10 patients with SD (study group) and 13 young people without such Syndrome. Morphological analysis (size and shape in three-dimensional approach) of the mandibular condyle was bilaterally determined by i-CAT Cone Beam Tomography (cone beam ®) imaging detector. The classification of the shape and size of the mandibular condyle was obtained by visualizations of coronal and sagittal planes, as well as by mandibular points. The statistical analyzes included determining the frequency of occurrence for the parameters considered above, with the use of Fisher's exact test, as well as estimating the average continuous quantitative variables by Student's t test. The average size of the mandibular condyle in the control group, left and right sides was 9.71 mm and 9.58 mm in sagittal analysis, while in the Group with Down syndrome was 10.15 mm and 9.97 mm. In coronal analysis the average size of the mandibular condyle, left and right sides, in the control group was 15.59 mm and 15.49 mm, while in the group with Down syndrome was 14.53 mm and 15.12 mm. Cone Beam Computed Tomography (CBCT) is a excellence imaging method employing reduced amount of radiation in a single measurement, low cost and versatility for image reconstruction. In the morphological analysis of the mandibular condyle of young people with or without Down syndrome detected by Cone Beam CT by sagittal and coronal visualizations, there were no significant changes of shape (round and straight) nor size (distance between the extreme anteroposterior and mediolateral mandibular points) comparing both groups. It is suggested that the continued growth potential of the mandibular condyle by temporomandibular joint cartilage remodeling can justify the results. Using tomographic additional incidences associated with a larger sample size could definitively corroborate the findings of this study. / A Articulação Tempormandibular (ATM) é considerada a mais complexa do corpo humano. Classificada como sinovial, e assim apresenta cápsula e disco articulares, membrana e líquido sinoviais e ligamentos. Particularmente, ATM é uma forma de ligação entre a cabeça da mandíbula (face) e o osso temporal (crânio), o que gera um componente articular mecanicamente estável. Há, no momento, escassos estudos referentes ao estudo da ATM em pacientes com Síndrome de Down (SD) trissomia do 21. O objetivo do presente estudo é analisar morfologicamente a cabeça da mandíbula por meio de Tomografia Computadorizada (TC) de Feixe Cônico em indivíduos jovens, portadores ou não, de SD. Após anuência ética, foram alocados 23 jovens (sexo masculino ou feminino e idade entre 18 e 20 anos), 10 portadores de SD (grupo de estudo) e 13 jovens sem a referida Síndrome. Avaliação morfológica (tamanho e forma em abordagem tridimensional) da cabeça da mandíbula foi determinada bilateralmente por tomógrafo i-CAT do tipo feixe cônico (cone beam®) com detector de imagem. A classificação da forma e do tamanho da cabeça da mandíbula foi obtida pelas visibilizações nos planos coronal e sagital, bem como pela mensuração da distância entre os pontos mandibulares extremos anteroposterior e médio-lateral. Análise estatística compreendeu determinação das frequências de ocorrência para os parâmetros acima considerados, com o emprego do Teste Exato de Fisher, bem como a estimativa da média das variáveis quantitativas contínuas pelo Teste t de Student. A média do tamanho da cabeça da mandíbula do Grupo Controle, do lado direito e esquerdo, em análise sagital foi de 9,71mm e 9,58mm, sendo que no Grupo com Síndrome de Down foi de 10,15mm e 9,97mm. Em análise coronal a média do tamanho da cabeça da mandíbula, lado direito e esquerdo, no Grupo Controle foi de 15,59 mm e 15,49 mm, enquanto que no Grupo com Síndrome de Down foi de 14,53 mm e 15,12 mm. Tomografia Computadorizada (TC) de Feixe Cônico é método de imagem de excelência que emprega reduzida quantidade de radiação em tomada única, a baixo custo e com versatilidade para reconstrução de imagens. Na análise morfológica da cabeça da mandíbula de jovens com ou sem Síndrome de Down por TC de Feixe Cônico por visibilização sagital e coronal, não foram encontradas alterações significantes de formato (arredondado e reto) e nem de tamanho (distância entre os pontos mandibulares extremos anteroposterior e médio-lateral) na comparação de ambos os grupos. Sugere-se que o contínuo potencial de crescimento da cabeça da mandíbula por remodelação da cartilagem da Articulação Temporomandibular possa justificar os resultados encontrados. Uso de incidências tomográficas adicionais, associadas a um maior tamanho amostral, poderiam corroborar em definitivo os achados do presente estudo.
328

Avaliação do crescimento mandibular e desenvolvimento dentário em crianças com má oclusão de Classe II, Divisão 1, naturais e induzidos pelo tratamento ortopédico com o Bionator de Balters

Pinto, Paulo Roberto dos Santos [UNESP] 27 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-27Bitstream added on 2014-06-13T19:20:03Z : No. of bitstreams: 1 pinto_prs_dr_arafo.pdf: 1147214 bytes, checksum: f6c2e1b004c27589634b2b9982a04229 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Introdução: O presente trabalho foi consubstanciado em três capítulos como se seguem: Capítulo I - Crescimento mandibular e desenvolvimento dentoalveolar no tratamento da Classe II, divisão 1, com bionator de Balters em função da maturidade esquelética; Capítulo II - Influência da época de tratamento, no processo de crescimento e desenvolvimento mandibular e dentoalveolar, durante a correção da má oclusão de Classe II, divisão 1, com a utilização do bionator de Balters e, 3- Influência do Bionator de Balters no processo de crescimento e desenvolvimento mandibular e dentoalveolar, durante a correção da má oclusão de Classe II, divisão 1. Material e Método: Na realização dos três capítulos do trabalho, foram utilizadas telerradiografias laterais em 45 graus de crianças Classe II divisão 1, com retrusão mandibular acompanhadas sem tratamento ou durante o tratamento com o aparelho bionator de Balters. Superposições mandibulares orientadas por referências fixas e estáveis representadas por implantes metálicos de tântalo inseridos na região anterior e posterior do corpo da mandíbula foram utilizadas para avaliação das mudanças no crescimento da mandíbula (corpo, ramo e base) e mudanças na erupção dos dentes decíduos e permanentes. Capítulo I: Foram avaliados 3 grupos de crianças Classe II divisão 1, dois tratados pelo período de um ano com o aparelho bionator de Balters (Grupo 1: 6 crianças com 7 a 8 anos e Grupo 2: 10 crianças com 9 a 10 anos) e um sem tratamento (Grupo controle: 7 crianças com 8 a 9 anos). Capítulo II - Foram avaliados 4 grupos em diferentes tempos de tratamento: Grupos 1 e 2, pacientes com idades esqueléticas variando de 7 a 8,5 anos de idade (10pacientes) e dos 9,3 aos 10,7 anos (10pacientes) respectivamente, tratados por 1 ano com o bionator de Balters. Grupos 3 e 4, pacientes com idades esqueléticas variando... / Introduction: The actual study was structured in three chapters. Chapter I: Mandibular growth and dentoalveolar development in the treatment of the Class II division 1 malocclusion with the bionator of Balters according to the skeletal maturation. Chapter II: Influence of the bionator of Balters treatment phase, in the process of mandibular and dentoalveolar growth and development, during the correction of the Class II, division 1 malocclusion. Chapter III: Evaluation of the Bionator of Balters influence in the mandibular and dentoalveolar growth and development process, during the correction of Class II division 1 malocclusion. Material e Method: It was used in the three chapters, lateral 45 degree cephalometric radiographs of Class II division 1 children with mandibular deficiency, followed without treatment or during the treatment with the orthopedic appliance bionator of Balters. Mandibular superposition using tantalun metallic implants as fixed and stable references positioned in the anterior and posterior mandibular body were used for evaluation of the growth modifications of the mandible (condyle, ramus and base of the mandible) and of the eruption changes of the deciduous and permanent teeth. Chapter I: Three groups of children with Class II division 1 malocclusion were evaluated. Two of them were treated for one year with the bionator of Balters appliance in different skeletal ages (Group 1: 6 children 7 to 8 years old and Group 2: 10 children 9 to 10 years old) and the other one was followed without treatment (Control Group: 7 children 8 to 9 years old). Chapter II: Four groups of children with Class II division 1 treated with the bionator of Balters were evaluated: Groups 1 and 2 – Patients with skeletal age ranging from 7 to 8,5 years(10patients) and 9,3 to 10,7 years(10patients) respectively, treated for the first year with the appliance... (Complete abstract click electronic access below)
329

Uso de osso alógeno córtico-medular fresco congelado em bloco para aumento posterior de mandíbula atrófica: estudo clínico, histológico e histomorfométrico em humanos / Cortico-cancellous fresh frozen allografts bone blocks for augmentation of atrophic posterior mandible: clinical, histological and histomorfometric study in humans

Rafael Rodrigues Dias 30 May 2014 (has links)
Rebordos residuais atróficos em região posterior da mandíbula são um desafio clínico para a instalação de implantes. Dentre as várias técnicas utilizadas para resolver este desafio, o enxerto onlay de osso autógeno - geralmente coletado da crista ilíaca -, enxertos interposicionais, distração óssea e lateralização do nervo alveolar inferior são os mais executados. Entretanto, referidas técnicas expuseram desvantagens, tais como a morbidade, aumento do tempo de cirurgia e custos. Como alternativa, o uso de enxerto alógeno pode ser considerado, uma vez que existem inúmeras vantagens, como na redução do tempo cirúrgico, grande disponibilidade óssea e diminuição significativa da morbidade. O presente estudo trata da avaliação de forma clínica, histológica e histomorfométrica de enxerto de osso alógeno fresco congelado no aumento ósseo da região posterior mandibular, permitindo, dessa forma, a instalação de implantes dentários. Dezesseis hemi-mandíbulas de 12 pacientes (4 pacientes tratados bilateralmente) demonstrando atrofia alveolar crítica eram tridimensionalmente reconstruídas por meio de enxertos alógenos de blocos ósseos frescos congelados córtico-medulares provenientes da epífise distal do fêmur. Um total de 30 blocos foram fixados com parafusos de titânio de 1,5mm, cobertos com osso bovino mineral e membrana de colágeno. Após seis meses, procedeu-se a instalação dos implantes e biópsias ósseas, colhidas através de trefinas e enviadas para análise histológica e histomorfométrica . Na sequência incluíram-se amostras de osso em parafina, preparadas com hematoxilina e eosina ou, em resina para usar uma técnica de corte de trefinas, com vermelho de alizarina e coloração com azul de Stevenel. Realizaram-se tomografias computadorizadas de feixe cônico logo após o procedimento de enxerto ósseo e no pós-operatório de 6 meses, anteriormente à colocação do implante (6 meses após a enxertia). Os implantes dentários foram observados até a reabilitação protética. Foram utilizados os testes estatísticos de Kruskal-Wallis e pós-teste Tukey. Distribuiram-se os blocos entre 9 pacientes do sexo feminino e três do sexo masculino, com idade entre 37 e 64 anos (média de 50,9 ± 8,3 anos). Cada hemi-mandíbula recebeu de 1 a 3 blocos (1,9 ± 0,7 blocos), sob anestesia local. O ganho ósseo em espessura pós operatória imediata foi de 6,3 ±1,4 mm e tardia de 4,5 ± 1,3mm, em altura o ganho pós operatório imediato foi de 4,8 ± 1.6mm e tardio de 2,6mm ± 2mm. Quatro blocos demonstraram pequena deiscência da ferida 15-21 dias após a cirurgia, tratados com a remoção de necrose dos tecidos moles seguido de terapia tópica com bochecho de clorexidina 0,12% e clorexidina gel 2% duas vezes ao dia, até o fechamento total. Um total de 30 implantes foi instalado com acompanhamento de 15 à 28 meses (19,8 ± 4 meses). No decorrer do primeiro ano perdeu-se apenas um implante. A taxa de sobrevivência dos implantes foi de 96,66%. Por sua vez, exames de histologia exibiram osso neoformado em contato com o osso residual do enxerto alógeno, e tecido conjuntivo. Não houveram evidências de infiltrado inflamatório. A análise histomorfométrica mostrou 18,9 ± 8,1 % de osso neoformado, 32,5 ± 14,8% de enxerto ósseo alógeno residual e 48,6 ± 14,9% de tecido conjuntivo. Os enxertos alógenos frescos congelados em blocos se comportaram como um arcabouço para osteocondução e permitiram neoformação óssea adequada. Ele pode ser considerado uma alternativa viável para a reconstrução de rebordos residuais mandíbulares atróficos na região posterior, permitindo a instalação de implantes e reabilitação protética funcional. / Residual bone ridge atrophy in the posterior mandible is a clinical challenge for dental implants placement. Among several techniques used to solve this situation, onlay autogenous bone graft usually harvested from the iliac crest, interposicional grafts, bone distraction and nerve lateralization are the most performed. However these techniques present some disadvantages such as morbidity, increased surgical time and costs. As an alternative, the use of allograft can be considered. There are advantages such as reduction of surgical time, lots quantity of bone and decreased morbidity. The aim of present the study was to evaluate clinical, histological an histomorphometrical aspects of fresh frozen bone allograft used to augment atrophic posterior mandible bone ridges to allow placement of dental implants. Sixteen hemi-mandibles of 12 patients (4 patients treated bilaterally) presenting critical alveolar atrophy were three-dimensionally reconstructed using cortico-cancellous fresh frozen allograft bone blocks deriving from distal femoral head. A total of 30 blocks were fixed with titanium 1.5mm screws and covered with particulate bovine bone mineral and collagen membrane. After six months, implants were inserted and bone biopsies were harvested and sent for histological and histomorphometric analysis. Bone samples were either embedded in paraffin, prepared for hematoxylin and eosin staining procedure or in resin to use a sawing and grinding technique, prepared for alizarin red and Stevenel\'s blue staining. Computed cone beam tomography scans were taken both at immediate postoperative bone grafting and previously to implant placement (6 months after grafting). Dental implants were observed after prosthetic rehabilitation. Kruskal-Wallis and post test Tukey statistical tests were used. Thirty blocks were distributed between 9 female and 3 male patients, aged between 37 and 64 years (mean 50.9 ± 8.3 years). Each hemi-mandibles received 1 to 3 blocks (1,9 ± 0,7 blocks) under local anesthesia. The immediate postoperative thickness bone gain s was 6.3 ± 1.4 mm and of 4.5 ± 1.3 mm 6 months after grafting. Post-operative bone height gain was 4.8 ± 1.6 mm and 2.6 ± 2 mm at 6 months. Four blocks presented small wound dehiscence 15 to 21 days after surgery, treated with necrotic soft tissue removal followed by chlorhexidine 0.12% irrigation, and local gel 2% twice a until total closure. A total of 30 implants were installed with follow-up from 15 to 28 months (mean 19,8 ± 4 months) . One implant was lost within the first year. Implant survival rate was 96.66%. Histology demonstrates newly formed vital bone in contact to residual acellular allograft bone, and connective tissue. There was no evidence of inflammatory infiltrate. The histomorphometric analysis showed 18,9 ± 8,1 % of newly formed bone, 32,5 ± 14,8 % allograft residual bone and 48,6 ± 14,9 % of connective tissue. The fresh frozen allografts behaved as a scaffold for osseoconductivity and allowed proper bone formation. It can be considered a viable alternative for reconstruction of atrophied mandible in the posterior region, allowing the installation of implants and functional loading
330

Stability of transverse expansion in the mandibular dental arch

Housley, Jeffrey A., January 2002 (has links) (PDF)
Thesis--University of Oklahoma. / Includes bibliographical references (leaves 83-85).

Page generated in 0.1106 seconds