• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 902
  • 584
  • 184
  • 96
  • 46
  • 42
  • 21
  • 18
  • 12
  • 11
  • 8
  • 8
  • 7
  • 7
  • 6
  • Tagged with
  • 2332
  • 775
  • 324
  • 323
  • 312
  • 235
  • 177
  • 148
  • 144
  • 141
  • 140
  • 135
  • 133
  • 123
  • 119
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
701

Excreção de patógenos e inocuidade das carcaças de bovinos alimentados com silagem de grãos úmidos de destilaria

Nunes, Letícia Borges January 2018 (has links)
Orientador: Roberto de Oliveira Roça / Resumo: O objetivo deste estudo foi determinar a excreção de patógenos e inocuidade da carcaça de bovinos alimentados com diferentes níveis de silagem inoculada de grãos úmidos de destilaria desengordurados (WDG). Um total de 100 bovinos machos não castrados, 50% Angus e 50% Nelore, foram divididos aleatoriamente entre quatro dietas (N = 25) compostas por diferentes níveis de silagem de WDG (0, 15, 30 e 45% da matéria seca dietética). Amostras de fezes foram colhidas por meio de suabe da junção reto anal, 15 dias antes do abate, para determinar as ocorrências e quantificação de Escherichia coli produtora de toxina Shiga (STEC), E. coli enteropatogênica (EPEC) e Salmonella spp. por meio da técnica qPCR. Também foram colhidas, 52 dias antes do abate, amostras de fezes de cada animal do piso do curral, logo após defecação, as quais foram submetidas a análises físico-químicas. Logo após o abate, a ocorrência e a contagem de indicadores higiênicos e sanitários, E. coli não patogênica, coliformes totais e bactérias aeróbias mesófilas, assim como, a ocorrência de STEC, EPEC e Salmonella spp., foram determinados a partir de amostras colhidas por meio de esponja da superfície das carcaças das regiões do coxão, flanco, peito e pescoço. Os resultados quantitativos foram submetidos a análises de variância e os dados binários foram submetidos a análises logísticas com razão de chances. Todas as análises estatísticas foram realizadas no software estatístico SAS 9.4 considerando um nível de signifi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to determine the pathogen excretion and carcass safety of cattle fed different levels of inoculated silage from degreased wet distillery grains (WDG). A total of 100 male, 50% Angus and 50% Nelore male bulls were randomly divided into four diets (N = 25) composed of different levels of WDG silage (0, 15, 30 and 45% of dietary dry matter) . Stool specimens were collected by rectal anal junction swab 15 days prior to slaughter to determine the occurrences and quantification of Shiga toxin-producing Escherichia coli (STEC), E. coli enteropathogenic (EPEC) and Salmonella spp. by the qPCR technique. Samples of faeces from each animal on the corral floor were also collected, 52 days before slaughter, immediately after defecation, which were submitted to physical-chemical analysis. Immediately after slaughtering, the occurrence and counting of hygienic and sanitary indicators, non-pathogenic E. coli, total coliforms, and mesophilic aerobic bacteria, as well as the occurrence of STEC, EPEC and Salmonella spp., were determined from samples collected by medium of the surface of the carcasses of the regions of the tail, flank, chest and neck. The quantitative results were submitted to analysis of variance and the binary data were submitted to logistic analyzes with odds ratio. All statistical analyzes were performed in SAS 9.4 statistical software considering a significance level of 5%. The results showed that there was no difference between treatments fo... (Complete abstract click electronic access below) / Doutor
702

Comparação da contaminação microbiana de dois sistemas de encaixe para sobredentaduras mandibulares retidas por implantes. Estudo clínico randomizado / Microbial contamination comparison of two attachment systems for implant retained mandibular overdentures - randomized clinical trial

Pinheiro, Marília Lamenha Lins 30 May 2018 (has links)
A colonização e proliferação de micro-organismos periodontopatogênicos na gengiva marginal aos implantes dentários, assim como ao redor de seus componentes protéticos, pode representar riscos à saúde dos tecidos peri-implantares, à semelhança do que ocorre com os tecidos periodontais. O objetivo deste estudo foi identificar e quantificar 32 espécies microbianas de biofilmes coletados das superfícies de dois sistemas de encaixe para sobredentaduras retidas por implantes: um esférico (Retentive Anchor, Institut Straumann AG, Suíça - RA) e um cilíndrico (Locator, Zest Anchors Inc., CA-USA - Loc), das próteses, implantes e sulcos peri-implantares, ao longo do tempo. Os biofilmes analisados foram coletados em um estudo randomizado envolvendo 24 pacientes portadores de prótese total superior e sobredentadura inferior retida por dois implantes com sistemas de encaixe esférico RA (n= 12) ou cilíndrico Loc (n= 12). Amostras de biofilme foram coletadas de sete sítios para cada implante, nos períodos: após a instalação de novos encaixes (baseline), assim como aos 3 e 12 meses subsequentes. A identificação e quantificação das espécies microbianas foram realizadas por meio da técnica de hibridização DNA-DNA Checkerboard. Os resultados foram submetidos à análise não paramétrica de modelo misto ANOVAF, e matriz de covariância não estruturada para cada tratamento, com nível de significância de 0.05, posteriormente ajustado por Benjamini-Hochberg false discovery rate (FDR). Considerando-se todos os sítios e períodos investigados em conjunto e as 32 espécies bacterianas investigadas, apenas a S. constellatus foi encontrada em maior abundância nos biofilmes associados ao sistema RA. A análise sítio-específica revelou maior prevalência das espécies S. constellatus e P. micra na rosca do componente macho do encaixe esférico RA e da espécie S. sanguinis na superfície externa do componente macho do encaixe cilíndrico Loc. De modo geral, pôde-se concluir que os sistemas de encaixe para retenção de sobredentaduras RA e Loc são colonizados por microbiotas com perfis semelhantes, embora esses sistemas exerçam influência seletiva sobre o padrão de colonização das espécies bacterianas S. constelatus, P. micra e S. sanguinis / The colonization and proliferation of periodontopathogenic microorganisms in the dental implants marginal gingiva, as well as around their prosthetic components, may represent risks to the health of the peri-implant tissues, similar to what occurs with the periodontal tissues. The objective of this study was to identify and quantify 32 microbial species of biofilms collected from the surfaces of two attachment systems for implant retained mandibular overdentures: one spherical (Retentive Anchor, Institut Straumann AG, Switzerland - RA) and one cylindrical (Locator, Zest Anchors Inc., CA-USA - Loc), of prostheses, implants and peri-implant sulcus, over time. The biofilms analyzed were collected in a randomized study involving 24 patients with superior complete dentures and inferior overdenture retained by two implants with spherical attachment RA (n = 12) or cylindrical Loc (n = 12) systems. Biofilm samples were collected from seven sites of each implant, at the periods: after new attachments installation (baseline), as well at the next 3 and 12 months. The microbial species identification and quantification were carried out using DNA-DNA Checkerboard hybridization technique. The results were submitted to the mixed model non-parametric analysis \"ANOVAF\" and non-structured covariance matrix for each treatment, with 0.05 significance level, later adjusted by \"Benjamini-Hochberg\" false discovery rate (FDR). Considering all the sites and periods investigated together and the 32 bacterial species investigated, only S. constellatus was found in greater abundance in the biofilms associated to the RA system. The site-specific analysis revealed a higher prevalence of S. constellatus and P. micra species on the male component of the RA spherical attachment and of S. sanguinis species on the outer surface of the male component of the cylindrical Loc attachment. In general, it can be concluded that the overdenture attachment systems RA and Loc are colonized by microbiotas with similar profiles, although these systems exert a selective influence on the colonization pattern of S. constelatus, P. micra and S. sanguinis bacterial species
703

Vliv stromů na kontaminaci půdy 137Cs / The influence of trees on contamination of soil with 137Cs

TRNKOVÁ, Michaela January 2019 (has links)
Nuclear weapons testing in the atmosphere and accidents in nuclear energy facilities in the last 50 years caused significant contamination of the environment. Half-life of certain leaked radionuclides is several decades and therefore they are still present in today's environment. That is the reason why there is still on going monitoring of radiation situation in the Czech Republic in order to determine the behaviour and kinetics of anthropogenic radionuclides in the environment and the severity of radiological impact on humans. The results of this monitoring serve to review the radiation situation, observe long-term trends and last but not least to gain new knowledge that could facilitate the management od radiological emergencies. The aim of this thesis was to measure the content of 137Cs in soils under and around leafy tree crowns in the area affected by radiation fall and to find out whether the tree's crown has an effect on the distribution of 137Cs in the soils below them. To this end, a research question has been set: Do tree crowns affect the distribution of cesium in the soils below them? For better intelligibility, the introduction of the thesis is devoted to information about ionizing radiation, basic terms and quantities in the field of ionizing radiation, sources of radionuclide contamination, especially the Chernobyl nuclear power plant accident, environmental and population contamination, and elements important for the practical part of this work. The theoretical part is followed by research methodology. The soil samples were collected under five leafy trees of the Walnut species that met the set criteria for collection. Under each tree, samples were taken in three directions at an angle of 120° always at the trunk, in the middle of the crown, at the edge of the crown and outside the crown. Thus, 12 samples per tree, a total of 60 samples. Dry and purified soil samples were measured by semiconductor gamma spectrometry which determined 137Cs radionuclide mass activity values as well as naturally occurring radionuclide40K. Graphs were generated from the measured values. Despite the frequent deviations that may be caused by natural phenomena or human activities, it was found out that tree crowns affect the distribution of 137Cs in the soils below them.
704

Dinâmica da geração e fluxo de chorume em aterro sanitário de pequeno porte a partir de monitoramento geofísico /

Helene, Livia Portes Innocenti. January 2019 (has links)
Orientador: César Augusto Moreira / Resumo: Aterros sanitários de resíduos sólidos são a forma de disposição final adequada mais utilizada no mundo devido a suas vantagens operacionais. O processo de instalação, no entanto, exige o desenvolvimento de diversos sistemas tecnológicos a fim de garantir uma disposição de resíduos segura em termos ambientais e de saúde pública. Ainda assim, a contaminação do ambiente subterrâneo pelos produtos da degradação dos resíduos sólidos (chorume) é recorrente. Diante dessas ocorrências, é necessário investigar a área com o objetivo de encontrar as falhas nos sistemas do aterro responsáveis pela contaminação; propor projetos de remediação e monitoramento. Este trabalho aplicou o método geofísico da eletrorresistividade em uma vala de resíduos de um aterro sanitário de pequeno porte com o intuito de diagnosticar a presença de chorume no aquífero e detectar possíveis imperfeições no sistema de impermeabilização. Adicionalmente, por meio de um monitoramento temporal do parâmetro resistividade, entender a dinâmica da geração e fluxo do chorume na área do aterro. Para tanto, o levantamento geofísico contou com 12 linhas de tomografia elétrica, adquiridas durante um período de 3 anos (2016, 2017 e 2018). Para complementar os resultados o método do potencial espontâneo foi aplicado na área no ano de 2018 com o objetivo de adicionar informações a respeito do estágio de degradação dos resíduos sólidos. Os resultados do parâmetro resistividade elétrica são apresentados em seções 2D e modelos de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Landfills are the most widely used destination in the world for municipal solid waste due to their operational advantages. The installation, however, requires the development of several technological systems in order to ensure a safe and environmentally correct disposal of waste. Nevertheless, the contamination of the subsurface by leachate is recurrent. In view of these occurrences, it is necessary to investigate the area in order to find the faults in the landfill systems responsible for the contamination; propose projects for remediation and monitoring of the area. Therefore, this project predicted the application of the resistivity method in order to diagnose the sources of contamination and to detect possible point of percolation through the geomembrane. By means of a temporal monitoring the present project aimed to understand the leachate generation and flow in the landfill area. For this purpose, the geophysical survey consisted of 12 electrical tomography lines, acquired during a three-year acquisition period (2016, 2017 and 2018). To complement the results, the self-potential method was applied in the area in the year 2018 with the purpose of adding information about the solid waste degradation stage. The results of the resistivity parameter are presented in 2D sections and 3D visualization models with discussions for the superficial level of acquisition, for the geomembrane level (-4m) and for the aquifer level (-10m). The analysis over the years allowed the identif... (Complete abstract click electronic access below) / Doutor
705

Estudo da resposta IP de solos argilosos contaminados por hidrocarbonetos e chorume / A study on the IP response from clayey soils contaminated by hydrocarbons and inorganic co mpounds.

Ustra, Andréa Teixeira 28 June 2013 (has links)
A tese de doutoramento apresenta uma pesquisa que teve como objetivo principal estudar a resposta IP gerada pela contaminação de solos argilosos por compostos orgânicos e inorgânicos. Ensaios de campo e laboratório foram realizados para investigar a sensibilidade do método IP à mudanças na propriedades petrofísicas provocadas pela contaminação. Um experimento controlado investigou o efeito IP gerado em amostras coletadas em torno de um aterro de resíduos urbanos, saturadas por diferentes concentrações de chorume, coletado no próprio local. Os resultados mostram um aumento do efeito IP em amostras ricas em CaCO3, observado mesmo para altas concentrações de chorume. Um segundo experimento controlado investigou o efeito do teor e tipo de argila e da salinidade na resposta IP. Misturas de esferas de vidro e diferentes teores de caulinita e montmorilonita foram saturadas por soluções de diferentes concentrações de NaCl. Os resultados obtidos mostram que o efeito da concentração de sais na resposta IP depende do teor de tipo de argila, sendo esse último dominante em relação ao efeito da salinidade. A concentração de sais e o teor de argila atuam de forma acoplada, intensificando o efeito IP. Em um terceiro experimento, a sensibilidade da resposta IP a presença de tolueno foi investigada. Misturas de areia e montmorilonita foram artificialmente contaminadas por diferentes concentrações de tolueno. Os resultados desse experimento mostram que o efeito desse contaminante na resposta IP é pequeno. Ainda assim, foi possível observar uma dependência da resposta IP com a concentração de tolueno que muda com o tempo, provavelmente devido a mudanças interfaciais químicas após a adição de tolueno. Com o objetivo de estudar o efeito da biodegradação do tolueno em solos argilosos na resposta IP gerada, duas colunas compostas de uma mistura de areia e caulinita, artificialmente contaminadas por tolueno, foram preparadas. Um fluxo de água subterrânea coletada em uma área contaminada foi estabelecido em uma das colunas (ativa), enquanto que uma solução de água deoneizada e NaCl foi estabelecido na outra (controle). A resposta IP das duas colunas foi monitorada por um período de quatro meses e nenhuma mudança na resposta elétrica das colunas que indicasse a ocorrência de biodegradação do tolueno foi observada. Os dados geoquímicos comprovam que não houve mudanças significativas durante o período do monitoramento, mesmo embora a presença de bactérias anaeróbicas vivas tenha sido verificada tanto na solução de entrada como na solução de saída da coluna ativa. Uma possível explicação para o tolueno não ter sido biodegradado de forma eficiente é a sua alta concentração na colunas. O último estudo realizado consiste na utilização do método IP para a investigação de uma área contaminada por BTEX (benzeno, tolueno, etil-benzeno e xileno). A contaminação ocorreu devido a derrames acidentais de quantidade não estimada de solventes no solo não impermeabilizado. O ensaio de campo revela uma zona de anomalia, caracterizada por baixas resistividade e cargabilidade e aumento da cargabilidade normalizada. Amostras de solo foram coletadas na área e tiveram suas propriedades elétricas medidas em laboratório. O contraste elétrico observado em campo não foi observado em laboratório, sugerindo que variações do teor de umidade podem estar contribuindo para a anomalia geofísica observada em campo. O teor de argila, bactérias totais e propriedades magnéticas foram medidas em diversas amostras coletadas na área. Os resultados dessas análises mostram que a distribuição do teor de argila não explica a anomalia observada. Entretanto, a população microbiana encontrada foi cinco ordens de magnitude maior na zona de anomalia. As propriedades magnéticas mostram que as amostras coletadas na zona da anomalia são mais ricas em magnetita. Os estudos realizados nessa pesquisa mostram que a resposta IP observada em estudos ambientais é afetada por propriedades petrofísicas como o teor de argila, teor de umidade, mineralogia e propriedades químicas do fluido dos poros. Entretanto a variação natural dessas propriedades também é esperada em ambientes dinâmicos. Consequentemente, isolar a contribuição de mudanças dessas propriedades devido a contaminação é uma tarefa complexa. / This PhD Thesis presents a research that aimed to study the IP response from soils contaminated by organic and inorganic compounds. Field surveys and laboratory experiments were conducted to investigate the sensibility of the IP method to changes in petrophysical properties due to contamination. A controlled experiment investigated the IP effect generated in soil samples collected around an urban waste disposal site, saturated by the leacheate generated at the site. The results show an IP effect increase on samples rich in CaCO3, observed even for high contaminant concentrations in the saturation solution. A second experiment investigated the effect of clay type and content and salinity on the IP response. Glass beads with varying concentration of kaolin and bentonite mixtures were synthesized and saturated by solutions with varying salt concentration. The results of this experiment show that the effect of salinity on the IP response depends upon clay type and content, being the clay effect dominant over the salinity effect. The effects of ionic concentration and clay content on the IP effect are coupled, enhancing the IP response. In a third experiment, the IP sensibility to toluene contamination is investigated. Sand and montmorillonite mixtures were artificially contaminated with varying toluene concentrations. The results show that the toluene effect on the IP response is small. Even though, there is an IP response dependency on toluene concentration that changes with time, probably due to interfacial chemical properties changes after the addition of toluene. With the purpose of studying the effect of toluene biodegradation on the IP response, two columns were packed with a sand and kaolinite mixture, artificially contaminated with toluene. A contaminated groundwater solution flux was established in one column (active), and a NaCl and deoneized water solution flux was established on the other column (control). The IP response from both columns was monitored for a period of four months. No significant changes in the electrical properties of these columns that could indicate toluene biodegradation was observed. Geochemical data confirmed that no significant changes occurred during the monitoring period, even though live anaerobic microorganisms were verified in the active column inflow and outflow. One possible explanation for the inefficiency in degrading toluene is its high concentration in the columns. The last study presented is a BTEX (benzene, toluene, ethyl benzene and xylene) contaminated area investigated with the IP method. The contamination events took place due to accidental spills directly into the soil, where the exact amount of contaminant disposed is unknown. The geophysical survey revealed an IP response anomaly, characterized by low resistivities and chargeabilities and normalized chargeability enhancement. Soil samples were collected at the site and its electrical properties were measured in the laboratory. The electrical contrast observed in the field was not observed in the laboratory, suggesting that moisture content could be contributing to the geophysical anomaly observed at the field. Clay content, total bacteria and magnetic properties were measured for some of the collected samples. The results show that the clay content distribution in the area does not explain the geophysical response observed. However, the microbial population was found to be over five orders of magnitude higher in the anomaly zone. Magnetic properties of the samples show that the anomaly zone is richer in magnetite. These studies show that the IP response observed in environmental studies is affected by petrophysical properties such as clay content, moisture content, mineralogy and pore fluid chemical properties. However, natural changes of these properties are also expected in dynamic environments. The isolation of the contribution of soil contamination to changes of these properties is a complex task.
706

Avaliação do potencial de aplicação do processo de irradiação na redução da população de Salmonella sp. inoculada em hambúrguer de carne de frango: aspectos sensoriais e vida-de-prateleira / Evaluation of the application potential of the irradiation process in the reduction of the Salmonella sp. population inoculated in chicken meat hamburger: sensorial aspects and shelf-life

Vieira, Vanessa dos Santos 15 July 2005 (has links)
A preocupação constante com a inocuidade e a qualidade dos alimentos irradiados, aliada à tendência de se estudar os aspectos sensoriais desses alimentos, foram a motivação para o desenvolvimento deste trabalho que teve como objetivos verificar os efeitos da radiação ionizante produzida pelo 60Co na sobrevivência de Salmonella sp em hambúrgueres de carne de frango congelados e verificar a aceitação do produto irradiado durante o seu período de estocagem. Amostras de hambúrguer de carne de frango congelados, inoculados com quatro cepas diferentes de Salmonella sp foram expostos a níveis de radiação com doses variando entre O e 3,5 kGy para verificação da sobrevivência da população de Salmonella sp presente. Amostras não inoculadas e irradiadas com doses de 0,5 e 7 kGy foram submetidas à avaliação sensorial por painel não treinado, pelo período de 120 dias, com o intuito de se verificar o decaimento da qualidade do produto. Os valores D10 encontrados para Salmonella sp variaram entre 1,02 e 1,32 kGy, portanto, as doses de 5 e 7 kGy, utilizadas nas fases seguintes do experimento, seriam suficientes para reduzir a população de Salmonella sp no produto em 5-6 ciclos logarítmicos. A exposição às doses de 5 e 7 kGy não afetou as características sensoriais do produto. A vida de prateleira do hambúrguer de carne de frango congelado e irradiado com doses de 5 e 7 kGy foi de, no mínimo, 120 dias, ou seja, igual à do produto não irradiado. / Safety and quality of irradiated foods are still of great concern to researchers and consumers, in general. The aims of this research were to study the effects of ionizing radiation from 60Co on the population of Salmonella sp inoculated in frozen chicken meat patties as well as on their sensory characterisitcs during the storage period. Samples of frozen chicken meat patties, inoculated with a pool of four strains of Salmonella sp, were exposed to irradiation doses varying from 0 to 3.5 kGy in order to determine their sensitivity (D10). Non inoculated samples of frozen chicken meat patties exposed to 5 and 7 kGy and a non inoculated and non irradiated sample were submitted to sensory evaluation by a non-trained panel. 010 values varied from 1.02 to 1.32 kGy Samples exposed to 5 and 7 kGy did not showed appreciable changes during the storage period of 120 days. Therefore, irradiation can be applied to chicken meat patties in order to improve their safety during a storage period of, at least, 120 days.
707

Avaliação da eficiência de uma zona alagadiça (wetland) no controle da poluição por metais pesados: o caso da Plumbum em Santo Amaro da Purificação/BA. / Investigation on the wetland efficiency for the control pollution of heavy metals: the specific case of "Plumbum" at Santo Amaro da Purificação/Bahia.

Anjos, José Ângelo Sebastião Araujo dos 24 February 2003 (has links)
Esta pesquisa teve o objetivo de avaliar a eficiência de uma zona alagadiça (wertland) que ocorre nas dependências de uma usina situada em Santo Amaro da Purificação, Bahia, como medida de controle da contaminação proveniente de um barramento de escória contaminada por metais pesados. Inicialmente, foi proposto um levantamento anual com amostragens semanais das águas pluviais e superficiais da zona alagadiça, com o intuito de avaliar a eficiência da zona alagadiça, por meio do levantamento das concentrações dos metais oriundos dos processos de lixiviação e/ou solubilização da escória nos seus pontos de entrada e saída do sistema alagado e, concentrações e potencial disponibilidade dos metais retidos nos sedimentos da zona alagadiça. Foram selecionados os seguintes parâmetros: para as águas pluviais o pH e o volume da chuva; para as águas superficiais as concentrações dos metais Chumbo (Pb), Cádmio (Cd), Zinco (Zn), Cobre (Cu), Alumínio (Al), Manganês (Mn), Ferro (Fe), Magnésio (Mg) e Cálcio (Ca) e os parâmetros de suporte pH, Eh, condutividade, Oxigênio Dissolvido (OD) e temperatura. Para o solo e sedimento da zona alagadiça as concentrações dos metais Pb, Cd, Zn e Cu e, determinação por análise por extração seqüencial do total removido pelo sistema nas suas diversas fases e a potencial disponibilidade dos metais pesados. Todavia, uma modificação da estratégia de pesquisa teve que ser feita em função de uma decisão judicial que determinou o recobrimento da escória e do ponto de entrada da zona alagadiça. Em função do ocorrido, a pesquisa foi dividida em três etapas considerando os levantamentos efetuados antes, durante e depois do recobrimento. Os dados levantados nos cinco meses antes do recobrimento mostraram que os metais cádmio, chumbo, cobre e zinco estão sendo retidos pela zona alagadiça e, que este sistema foi eficiência de 100% para os metais cobre e zinco, 82% para o chumbo e 73% para o cádmio. Os parâmetros de suporte que influenciam a remoção destes metais foram o pH, entre neutro a alcalino, e Eh, na faixa de oxidação das águas superficiais, além da alta capacidade de troca catiônica da montmorilonita presente no sedimento. Quanto ao potencial de disponibilidade dos metais, cádmio, chumbo e zinco apresentam valores elevados, enquanto o cobre encontra-se preferencialmente concentrado na fase residual. A segunda etapa do levantamento realizada durante o recobrimento da escória demonstrou que ocorreu pouca migração dos metais da zona alagadiça, embora a empresa não tenha obedecido as normas técnicas para o recobrimento da escória. Na terceira etapa foi realizado levantamento na saída da zona alagadiça e da drenagem próxima ao rio Subaé. As análises levantadas demonstraram a grande disponibilidade do cádmio no sistema alagado, este mecanismo foi acionado a partir da erosão do solo contaminado disposto sobre a escória e a grande solubilidade do cádmio. Desta forma pode-se conclui que as zonas alagadiças estão sendo eficientes na retenção dos metais. A redução de sua área é indesejável, pois tende a diminuir sua eficiência, como sistema de controle da poluição das águas superficiais, recomenda-se a construção de nova zona alagadiça a jusante da existem. / A lead ore smaller which operated from 1960 to 1993 in Santo Amaro da Purificação, Bahia State, disposed of 490,000 tons of slag in a landfill situated in the situated in the industrial site. Earthworks formed a man-made wetland downstream of the slag landfill, which acted as a metal retaining systems, thus preventing further water pollution. This research aimed at investigating the efficiency of this wetland as a water pollution control system. The research plan scheduled weekly samplings of rainfall, rainwater pH and water runoff in two points corresponding to the input and the output of the wetland for determination of metals concentration (Pb, Cd, Cu, Zn, Al, Mn, Fe, Mg, Ca), as well as water pH, Eh, conductivity, temperature and dissolved oxygen (OD). In addition, soil and sediment in the wetland were sampled and analyzed for Pb, Cd, Zn and Cu by sequential extraction methods. However, a Court ruling following a lawsuit for environmental damage led to the slag being covered by clayish soil weeks after sampling began. As a consequence, the point where waters entered the wetlands has been covered. Hence, sampling in this point has been discontinued and a new sampling point was established downstream of the wetland, at a point where its waters flow into a river. Results showed that before cover-up, Pb, Cd, Cu and Zn were being retained in the wetland at rates reaching 100% for Cu and Zn, 82% for Pb and 73% for Cd. After cover-up, Cd was being released into the waters. Sequential extraction showed that only Cu is not available for leaching, since it is mostly concentrated in the insoluble phase. On the other hand, Pb, Cd and Zn are potentially available, thus could re-enter other media if wetland is disturbed. The wetland acts as an efficient device for retaining metals because of near neutral water pH, oxidizing water Eh, and the existence of montmorillonite clay in the sediments, which features high cationic exchange capacity. It is concluded that this involuntary wetland has been working, as an efficient system for water pollution control. The reduction in its size, due to the cover-up activities, is undesirable. Hence, a new constructed wetland is proposed downstream of the existing one. Then, we can end that the wetland of Plumbum this being efficient in the control of the metals, from when interferences anthropogenetic that maximize the capacity of support of this system don’t happen.
708

Medição, predição e análise de partículas aéreas em salas cirúrgicas. / Measurement, prediction and analysis of airborne particles in surgical rooms.

Pereira, Marcelo Luiz 10 October 2008 (has links)
Os sistemas de condicionamento de ar exercem função importante em uma sala cirúrgica, que é proteger a ferida cirúrgica e os equipamentos estéreis dos microrganismos carreados pelo ar. Essa proteção é feita pelo controle simultâneo da movimentação e distribuição do ar, da temperatura, da umidade, da filtragem, das infiltrações de ar de outros setores, entre outros. Esses são fatores que afetam diretamente a quantidade de partículas aéreas presentes em uma sala cirúrgica. Dentro deste contexto, no presente trabalho foi desenvolvido um modelo matemático para predição da concentração de partículas em salas cirúrgicas e para determinação da importância relativa dos fatores que interferem na geração e remoção dessas partículas. O modelo proposto baseia-se no balanço de massa para o cálculo da concentração de partículas, que foi aplicado e validado com os dados obtidos em salas cirúrgicas com diferentes tipos de sistemas de condicionamento de ar. Nessas salas cirúrgicas foram realizadas medições de variáveis ambientais considerando diferentes situações que normalmente ocorrem na rotina de salas cirúrgicas. Para cada uma das condições analisadas, é proposto um determinado conjunto de parâmetros relativos ao ambiente, ao sistema de condicionamento de ar e às concentrações de partículas provenientes das diversas fontes, que são utilizados como dados de entrada no modelo. O modelo que está sendo proposto também pode ser utilizado como uma importante ferramenta para auxiliar na análise específica dos fatores que afetam tanto a geração como a remoção de partículas. / Air conditioning systems exert an important function in surgical rooms, to protect the surgical wound and the sterile equipments from airborne infected particles. This protection is achieved by means of a simultaneous control of the movement and distribution of the air, of the temperature, of the humidity, of the filtering, of air infiltrations from other sections etc. Those factors directly affect the amount of airborne particles present in a surgical room. Within this context, the present work aimed to develop a mathematical model for the prediction of particle concentrations in surgical rooms and for the determination of the relative importance of the factors that interfere in the generation and removal of those particles. The proposed model, based on mass balance for the calculation of the particle concentrations, has been applied and validated with the data obtained from different types of air conditioning systems in which the measurements were carried out, as well as with different conditions that commonly occur in the routine of surgical rooms. For each one of these conditions, a certain group of relative parameters is proposed to the environment, to the air conditioning system, and to the concentrations of particles originated from the different sources, which are used as input data to the model. The proposed model can also be used as an important tool to aid in the specific analysis of the factors that affect both particle generation and removal.
709

Efeito da adição de Lactobacillus rhamnosus em queijos Minas frescal sobre as contagens de Staphylococcus aureus e Listeria monocytogenes / Effect of Lactobacillus rhamnosus on growth of Staphylococcus aureus and Listeria monocytogenes in cheese

Prezzi, Lígia Eleonor 31 October 2014 (has links)
O objetivo deste estudo foi avaliar o efeito inibitório de Lactobacillus rhamnosus sobre as contagens de Staphylococcus aureus e Listeria monocytogenes, aspergidos isoladamente ou em combinação sobre a superfície de queijo Minas Frescal, durante armazenamento por 21 dias a 7ºC. O delineamento consistiu em esquema fatorial 2x2x2, sendo 8 tratamentos com 4 repetições. As características físico-químicas (pH, atividade de água, umidade, teor de gordura, proteína e perfil de textura) foram determinadas nos queijos dos tratamentos sem adição de L. rhamnosus ou contendo este probiótico (T1 e T2, respectivamente). Verificaramse as contagens de L. rhamnosus, S. aureus e L. monocytogenes nos queijos de todos os tratamentos nos dias 1, 7, 14 e 21 de armazenamento. Foram também analisados os percentuais de sobrevivência dos microrganismos submetidos a condições de simulação do trato gastrointestinal (TGI) utilizando ensaios in vitro. Não houve efeito significativo (P>0,05) entre os parâmetros físico-químicos dos queijos dos tratamentos T1 e T2. As contagens de L. rhamnosus aumentaram (P<0,05) em todos os tratamentos a partir do dia 7 de armazenamento, estabilizando ao redor de 108 UFC/g, sendo que a presença concomitante de L. monocytogenes e/ou S. aureus nos queijos não influenciou a contagem de L. rhamnosus. L. rhamnosus diminuiu em cerca de 1 ciclo log as contagens de L. monocytogenes, e não exerceu efeito inibitório sobre S. aureus após 21 dias. S. aureus não sobreviveu ao teste de simulação ao TGI. No entanto, L. rhamnosus e L. monocytogenes apresentaram percentuais de sobrevivência entre 74,6% a 86,4%, e entre 75,8% a 94,1%, respectivamente. Os resultados demonstraram que a adição de L. rhamnosus não alterou as características físico-químicas dos queijos Minas frescal, porém exerceu efeito inibitório sobre L. monocytogenes, mas nenhum efeito sobre S. aureus. A utilização de L. rhamnosus como probiótico apresenta um potencial para inibição de L. monocytogenes na fabricação de queijos Minas frescal. São necessários estudos sobre os mecanismos envolvidos na competição entre as bactérias por substratos no alimento, bem como sua sobrevivência nas condições do TGI em ensaios in vivo. / The aim of this study was to evaluate the effects of Lactobacillus rhamnosus on growth of Staphylococcus aureus and Listeria monocytogenes in Minas frescal cheese during 21 days of storage at 7ºC. The experimental design was totally randomized, in a 2x2x2 factorial arrangement with 8 treatments and 4 replicates per treatment. Physical chemical parameters such as pH, moisture, water activity, fat, protein and texture profile analysis were carried out in cheeses where no microorganism were inoculated (T1) and in the cheeses inoculated with the probiotic bacteria, L. rhamnosus (T2). The counts of L. rhamnosus, S. aureus and L. monocytogenes were examined on days 1, 7, 14, 21 of storage. Survival percentage of the bacteria after exposure to simulated gastrointestinal conditions was studied in vitro. Statistical analysis indicated that there were no significant differences (P>0,05) among the means of the physical chemical parameters analyzed in treatments 1 and 2. From day 7 on, the counts of L. rhamnosus increased (P<0,05) in all treatments, stabilizing and reaching up to 108 CFU/g. It was noticed that the concurring presence of L. monocytogenes and/or S. aureus in the cheese samples did not show influence in the counts of the probiotic bacteria. The L. rhamnosus caused about 1 log cycle reduction in the counts of L. monocytogenes, but showed no inhibitory effect on S. aureus at the end of the period of storage. S. aureus did not survive the exposure to simulated gastrointestinal conditions. However, L. rhamnosus and L. monocytogenes showed survival percentages varying from 74,6% to 86,4%, and from 75,8% to 94,1%, respectively. The results showed that the addition of L. rhamnosus had no influence on the physical chemical characteristics of the Minas frescal cheese and no inhibitory effect on S. aureus, nevertheless demonstrated inhibitory effect on L. monocytogenes. The addition of probiotic strains of L. rhamnosus in Minas frescal cheese represents potential for L. monocytogenes inhibition. It is essential to carry out studies on the mechanisms involved in the competition for substrate by bacteria, as well as their survival to simulated gastrointestinal conditions in in vivo experiments.
710

O impacto do uso do solo na contaminação por agrotóxicos das águas superficiais de abastecimento público / The impact of land use in the contamination of the superficial waters of public supply by pesticides

Veiga, Denise Piccirillo Barbosa da 05 May 2017 (has links)
Introdução: A qualidade e quantidade das águas superficiais estão diretamente relacionadas com as atividades econômicas presentes nas bacias hidrográficas e seus níveis de preservação. O aumento no uso de agrotóxicos pode contribuir para a contaminação do solo e da água, sobretudo em bacias hidrográficas agrícolas. A prevenção da contaminação dos mananciais é essencial para garantir a qualidade da água e diminuir os riscos à saúde humana, para tanto é preciso identificar como o uso e a ocupação do solo impactam os recursos hídricos, sua qualidade e seu equilíbrio hidrológico. Objetivo: Caracterização ambiental de duas bacias de mananciais de abastecimento público de forma a identificar áreas vulneráveis quanto à contaminação de agrotóxicos. Método: Aplicação do modelo hidrológico SWAT para caracterização da bacia e para simulação do ciclo hidrológico. Divisão da bacia hidrográfica em subbacias de acordo com o predomínio da ocupação do solo. Trabalho de campo para identificação de fontes pontuais de contaminação. Resultados: Foi verificado o impacto do uso e ocupação do solo no balanço hídrico das bacias. O escoamento superficial foi um dos principais meios de contaminação dos corpos dágua e esteve relacionado a presença de vegetação. Áreas de maior preservação apresentaram menor escoamento superficial enquanto àquelas com predomínio de agricultura e de solo exposto apresentaram valores maiores. A partir desses dados foram identificadas as áreas prioritárias para melhor gestão do uso de agrotóxicos por apresentarem potencial de contaminação dos corpos dágua. Conclusão: O modelo SWAT e as ferramentas de geoprocessamento se mostraram adequadas para a caracterização do uso do solo e os resultados fornecem subsídios para melhoria das ações de vigilância da qualidade da água nos municípios / Introduction: The surface waters quality and quantity are directly related to the economic activities present in the river basins and their levels of preservation. The increase in the use of pesticides can contribute to the contamination of soil and water, especially in agricultural watersheds. Preventing the contamination of water sources is essential to guarantee water quality and reduce risks to human health. Therefore, it is necessary to identify how the land use impacts water resources, their quality and their hydrological balance. Objective: Environmental characterization of two watersheds of public supply sources in order to identify vulnerable areas for the contamination of pesticides. Method: Application of the SWAT hydrological model for basin characterization and simulation of the hydrological cycle. Division of watershed in subbasins according to the predominance of the land use. Fieldwork to identify point sources of contamination. Results: The impact of land use and occupation on the water balance of the watersheds was verified. Surface runoff was one of the main means of contamination of water bodies and was related to the presence of vegetation in the area. Areas of greater preservation presented lower surface runoff while those with predominance of agriculture and exposed soil showed higher values. Priority areas for better use of agrochemicals were identified because they present potential for contamination of water bodies. Conclusion: The SWAT model and spatial tools were adequate for the characterization of land use and the results provide subsidies for the improvement of water quality monitoring actions in municipalities

Page generated in 0.049 seconds