• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 11
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 739
  • 739
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Análise microbiológica da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados: estudo em cães

Shibli, Jamil Awad [UNESP] 17 April 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-04-17Bitstream added on 2014-06-13T20:17:45Z : No. of bitstreams: 1 shibli_ja_me_arafo.pdf: 739694 bytes, checksum: 57c9b17fc168fc0329fc6f5001a03672 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A microbiota presente na peri-implantite induzida por ligadura, em diferentes superfícies de implantes osseointegrados, foi analisada em 6 cães adultos machos. 36 implantes osseointegrados (9 Ticp: titânio comercialmente puro; 9 TPS: titânio plasma spray; 9 HA: hidroxiapatita; 9 superfícies tratadas com ácidos) foram inseridos e distribuídos igualmente 3 meses após exodontia de todos os pré-molares inferiores. Após um período de 3 meses de osseointegração, os implantes receberam os cicatrizadores. Decorridos 45 dias de cicatrização, amostras peri-implantares foram colhida, utilizando pontas de papel, no período 0 e após a colocação de ligaduras com fio de algodão, nos períodos 20, 40 e 60 dias. A contagem total de microrganismos (CTM) e a proporação de A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermedia, Campylobacter sp, Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, bastonetes anaeróbios Gram-negativos, Streptococcus beta-hemolíticos, Eikenella corrodens e Candida sp. foram analisadas. Não houve diferença da CTM entre as diferentes superfícies (p>0,05). A Pg não foi detectada no tempo 0; nos tempos 20 e 40 foi detectada em 12 implantes (4 Ticp, 4 HA, 2 TPS e 1 Sup. Trat. com ácidos) e no período 60 dias, em 9 (2 Ticp, 3 HA, 2 TPS e 1 Sup. Trat. com ácidos), tendo menor afinidade à superfície tratada com ácidos. Pi foi detectada em 5 implantes (2 Ticp, 2 HA e 1 Sup. Trat. com ácidos) no período 0 e em 100% dos implantes nos demais períodos. Fusobacterium sp. foi detectado em todos os períodos, tendo uma maior afinidade à HA. Streptococcus beta-hemolíticos foi detectado em 6 implantes (3 Ticp, 1 TPS e 2 HA) no período 0 e 30, 26 e 24 implantes respectivamente nos períodos 20, 40 e 60. Campylobacter sp. e Candida sp. foram detectadas em baixas proporções. Os demais microrganismos não... . / The microbiota associated with ligature-induced peri-implantitis, in different dental implants surfaces, was investigated by cultivation on enriched non-selective and various selective solid media, in 6 mongrel dogs. 36 dental implants (9 Ticp: titanium commercially pure; 9 TPS: titanium plasma spray; 9 HA: hidroxiapatite; 9 surfaces acid-etched) were placed in a similar distribution in all dogs 3 months after extraction of all premolars in mandible. Following a healing period of 3 months, healing abutments were installed and 45 days after cotton ligatures were placed and oral-cleaning procedures abolished for 2 months to induce vertical bone loss of about 40%. Microbial samples were with paper points on day of ligature placement and after 20, 40 and 60 days. The total number of cultivable bacteria and proportions of A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermediate, Campylobacter sp., Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, Enteric Gram-negative rods, beta-hemolytic Streptococcus, Eikenella corrodens and Candida sp. were analyzed. No significant microbiological differences were observed among the different surfaces (p>0,05). Pg was not detected in the time 0; already in the times 20 and 40 were detected in 12 dental implants (4 Ticp, 4 HA, 2 TPS and 1 acid-etched surface) and in the period 60 days, in 9(2 Ticp, 3 HA, 2 TPS and 1 acid-etched surface), tends smaller affinity to eh surface with acids-etched surface. Pi was detected in 5 implants (2 Ticp, 2 HA and 1 acid-etched surface) in the period 0 and in 100% of implants in other periods. Fusobacterium sp. was detected in all the periods, tends a larger affinity to HA. Beta-hemolytic Streptococcus was detected in 6 implants (3 Ticp, 1 TPS and 2 HA) in the period 0 and 30, 26 and 24... (Complete abstract, click electronic address below).
102

Influencia do desenho dos implantes endosseos na distribuição de tensões apos aplicação de cargas verticais e obliquas : analise estrutural e fotoelastica / Influence of dental implant design on tensions distribution after vertical and oblique loading : a structural and phtoelactic study

Perez, Miguel Angel Jaimes 18 July 2008 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T23:04:29Z (GMT). No. of bitstreams: 1 Perez_MiguelAngelJaimes_M.pdf: 6909101 bytes, checksum: 41413f644c388e8bd46795ab371670ee (MD5) Previous issue date: 2008 / Resumo: Este estudo teve como objetivo analisar a influência do desenho dos implantes endósseos na distribuição de tensões geradas nos modelos fotoelásticos após aplicação de cargas verticais e oblíquas a 7,5N, em quatro marcas comerciais de implantes endósseos. Foram selecionados doze implantes, divididos em quatro grupos: I.) Máster Conect Cônico1 4,3 x 13 mm; II.)Titamax Ti Medular2 3,75 x 13 mm; III.) Colosso3 RC 4,0 x 13mm; IV.) Bicon Uncoated Implant4 3,5 x 11mm, cada grupo contendo 3 implantes da mesma marca comercial. Através da Microscopia Eletrônica de Varredura foi analisado o desenho estrutural dos implantes. Para a análise da distribuição de tensão foram confeccionados oito modelos em resina fotoelástica com dimensões de 40 mm x 10 mm de base e 30 mm de comprimento. Dois implantes para cada grupo foram posicionados e fixados no interior dos modelos fotoelásticos. Uma vez verificada a ausência de tensões nos oito modelos foram iniciados os ensaios. Quatro modelos dos diferentes grupos receberam cargas verticais e quatro receberam cargas oblíquas de 7,5N. Por meio do polariscópio circular pertencente ao laboratório de Materiais Dentários e Prótese da USP-Riberão Preto, foi possível visualizar as franjas de tensões geradas nos modelos. Cada seqüência foi fotografada, sendo mantida a mesma distância focal em todos os ensaios. Os resultados obtidos foram analisados por grupos. O Grupo I, implante de hexágono interno longo com porção cervical polida, topo das roscas arredondadas, passos das roscas contínuas, espirais angulados e configuração cônica, apresentou concentração das tensões na região apical, quando submetida à carga vertical e oblíqua. O Grupo II, implante de hexágono externo, porção cervical polida, topo das roscas em forma de "v", passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões na região apical, médio e cervical do implante quando submetida à carga vertical e oblíqua. O Grupo III, implante com hexágono interno, porção cervical polida, topo das roscas em forma cônica, passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. O Grupo IV, implante com sistema cone morse, ombro cervical inclinado, platô ou barbatanas, topo do platô quadradas, passos do platô descontinuais, e configuração cilíndrica, distribuiu as tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. Baseado nos resultados obtidos e dentro da metodologia deste estudo conclui-se que: O grupo I, de configuração cônica concentrou a distribuição das tensões em região apical. Os grupo II, III e IV, de configuração cilíndrica, distribuíram as tensões com intensidade e localização similares nos terços apical médio e cervical. O presente estudo evidenciou haver diferenças na distribuição das cargas de um tipo de implante para outro, levando acreditar que essas diferenças possam ter relação com o desenho das roscas e platô. / Abstract: The meaning of this study was analyze on 4 dental implants brands the influence of its thread design on tensions distribution generated thru photoelastic models, after applying a 7.5N load on vertical and oblique directions. Twelve implants, organized in four groups had been selected: I.) Máster Conect Cônico1 4.3 x 13 mm; II.) Titamax Ti Medular2 3.75 x 13 mm; III.) 4,0 Colosso3 RC x 13mm; IV.) Bicon Uncoated Implant4 3.5 x 11mm, being in each group, three dental implants of the same commercial brand. The structural designs of the implants were analyzed with Electronic Microscopy Sweepings. For the tension distribution analysis, eight models had been confectioned in photoelastic resin with 40mm x 10mm base dimensions and 30 mm of length. Two implants of each group had been located and fixed in the interior of photoelastic models. Once verified the absence of tensions in the eight models the analysis were started. Four models of the different groups had received 7.5N load on vertical and four received this same load on oblique direction. By means of the circular polariscope developed in the Dental Materials and Prostheses laboratory the Ribeirão Preto Dental School (USP/RP), it was possible to visualize the tensions fringes generated in the models. Each sequence was photographed, being kept the same focal distance in all the assays. The gotten results had been analyzed by groups. Group I., implants with long internal hexagon and polishing cervical portion, top of rounded off threads, angled steps of continuous threads, spirals and conical configuration, presented tensions concentration on the apical region, when submitted to the vertical and oblique load. Group II, implants with external hexagon, polishing cervical portion, top of threads in form of v, angled steps of continuous threads, spirals and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions of the dental implants, when submitted to the vertical and oblique load. Group III., implants with internal hexagon, polishing cervical portion, top of threads in conical form, steps of threads continuous, spirals angled and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions . Group IV, implants with cone morse system, inclined cervical shoulder, square shaped threads, fin or plateau, angled plateau steps discontinuous, and cylindrical configuration, distributed the tensions on the apical, medial and cervical regions after the application of vertical and oblique loads. Based in the results gotten and respecting the limitations of this study it can be concluding that: Group I. with conical configuration, the tension distributions is concentrated on the apical region. Groups II, III and IV, with cylindrical configuration, had distributed the tensions with similar intensity and localization on the apical, medial and cervical regions. In the present study it is evidenced to have differences in the distribution of loads on the dental implants analyzed, being not evident that these differences have relation with the threads design. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
103

A description of dental implants placed at Tygerberg Oral Health Centre

Mahmoud, Hussein January 2019 (has links)
Magister Scientiae Dentium - MSc(Dent) / Purpose This study analyzed the dental surgical implant therapy in the past 5 years at Tygerberg Oral Health Centre, UWC Dental School, Cape Town, South Africa. The findings of this study serve as a guideline for the estimation of the prevalence in this dental hospital. The importance of this study was to aid in the establishment of the formalized electronic database for dental implant therapy. The data generated will form a foundational basis for future studies that may be conducted in the field of implantology. Methodology A retrospective cross-sectional study was conducted at the Tygerberg Oral Health Centre. The data was collected from the implant dental records for the years 2012-2017. Variables measured included the patient demographics such as age, gender, an implant placed by type, length, width, and anatomical location. Frequencies and means of data were generated using IBM SPSS v20.
104

Análise biomecânica de próteses unitárias sobre implante cone Morse em região pré-maxilar variando-se o tamanho do implante e tipo de ancoragem óssea : estudo pelo método dos elementos finitos 3-D /

Oliveira, Hiskell Francine Fernandes e. January 2017 (has links)
Orientador: Fellippo Ramos Verri / Banca: Karina Helga Turcio de Carvalho / Banca: Joel Ferreira Santiago Junior / Resumo: Análise biomecânica de próteses unitárias sobre implante cone Morse em região pré - maxilar variando - se o tamanho do implante e tipo de ancoragem óssea. Estudo pelo método dos elementos finitos 3 - D . [Dissertação]. Araçatuba: Faculdade de Odontologia da Universidade Estadual Paulista; 2017. Resumo Este trabalho teve como objetivo analisar a distribuição das tensões em próteses unitárias implantossuportadas de cone morse, em região de maxila anterior, variando o tipo de ancoragem óssea em colocação convencional, bicorticalizado e bicorticalizado com levantamento de assoalho nasal, com diferentes comprimento s do implante, sendo eles de 8,5, 10 e 11,5mm e diâmetro de 4,0 mm, através do método dos elemen tos fin itos tridimensionais. F oram simulados 3 modelos tridimensionais maxilares da região anterior envolvendo o elemento 11, com auxílio de programas de criação de modelos a partir de tomografias, o InVesalius (CTI, São Paulo, Brasil) e programas de desen ho assistido, o Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) e o SolidWorks 2011 (SolidWorks Corp, USA). Os modelos dos blocos ósseos foram reconstruídos a partir da tomografia computadorizada, com a presença de um implante nas dimensões citadas acima, com coroa livres de metal em zircônia e cimentada s. Os modelos 3D foram exportados para o programa de elementos finitos FEMAP v.11 (Siemens Product Lifecycle Management Software Inc.USA) para dis cretização dos modelos, geração da malha de elementos finitos e análise posterior a processamento no programa NEiNastran 11 (Noran Engineering, Inc., USA). Foram aplicadas cargas de 178N, em ângulo de 0º, 30º e 60º, considerando - se o longo eixo do im plante como referência . Os resultados foram visualizados por meio de mapas de deslocamento, tensão de von Mises, tensão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to analyze the distribution of tensions in morse tapper implants supporting single crowns in the anterior region of maxilla, varying the type of bone anchorage in conventional, bicorticalized and bicorticalized placement with nasal floor elevation, and different lengths of implants (8.5, 10 and 11.5mm) with 4.0 mm of diameter, using the 3D finite element analyses. Three 3-dimensional maxillary models of the anterior region including element #11 were simulated using software InVesalius for CT Scan recomposition (CTI, São Paulo, Brazil) and CAD-software Rhinoceros 3D 4.0 (NURBS Modeling For Windows, USA) and SolidWorks 2011 (SolidWorks Corp, USA). The bone block models were reconstructed from the computed tomography, with the presence of an implant in the dimensions mentioned above, with cemented zirconium metal free crowns. The 3D models were exported to the FEMAP v.11 finite element software (Siemens Product Lifecycle Management Software Inc.) for models discretizadion, mesh generation and post-processing analysis after processing progress in the NEiNastran 11 program (Noran Engineering, Inc ., USA). Loads of 178N were applied at angle of 0º, 30º and 60º, considering the implant long axis as reference. The results were visualized by means of displacement maps, von Mises maps, Max Principal maps and microstrain. Analyzing all stress maps, the bicortical models were the ones that showed with better stress and strain distributions, both in the implant a... (Complete abstract click electronic access below) / Mestre
105

Análise das intercorrências e complicações interferentes na instalação e perda primária dos implantes dentais osteointegráveis - um estudo retrospectivo / Analysis of intercurrences and complications interfering in the placement and primary loss of osseointegratable dental implants a retrospective study

Silva, Alessandro Costa da 09 October 2008 (has links)
Intrinsecamente, todo procedimento cirúrgico apresenta um certo índice de intercorrências e/ou complicações associadas. Hemorragias, infecções, parestesias ou disestesias e perda primária dos implantes são algumas das intercorrências e complicações mais comuns relacionadas a procedimentos cirúrgicos para implantodontia. Este estudo avaliou retrospectivamente o índice de intercorrências e complicações após cirurgia para a instalação de implantes dentais osteointegráveis. Foram avaliados, retrospectivamente, 660 prontuários clínicos de pacientes submetidos à instalação de implantes osteointegráveis no período 8 anos atendidos na Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba - Unicamp. Os resultados demonstraram que houve um maior índice de intercorrências e complicações quando os pacientes eram atendidos por alunos de especialização (p= 0,015) e quando o exame por imagem realizado era somente a radiografia panorâmica convencional (p= 0,011). Os resultados demonstraram também um maior índice de intercorrências e complicações nos pacientes quando estes eram submetidos a procedimentos cirúrgicos de reconstrução óssea alveolar (p< 0,0001). A presença de infecção pós-operatória influenciou significativamente para o aumento no índice de perda primária de implantes (p< 0,0001). / Intrinsically, every surgical procedure presents a certain rate of associated intercurrences and/or complications. Hemorrhages, infections, paresthesias or dysesthesias and primary loss of implants are some of the most common intercurrences and complications related to surgical procedures in implant dentistry. This study conducted a retrospective evaluation of the rate of intercurrences and complications related to patients submitted to osseointegratable dental implant placement. A retrospective evaluation was made of 660 clinical record charts of patients submitted to osseointegratable dental implants in the period of 8 years, attended in the Oral and Maxillofacial Surgery Department of Piracicaba Dental School - Unicamp. The results showed that there was a higher rate of intercurrences and complications when patients were attended by residents (p= 0.015) and when the panoramic radiograph was the only preoperative image exam requested (p= 0.011). The results also showed a higher rate of intercurrences and complications in patients when they were submitted to surgical procedures of alveolar bone reconstruction (p< 0.0001). The presence of post-operative infection had a significant influence on the increase in the primary loss of implants (p< 0.0001).
106

Avaliação histológica e histomorfométrica do comportamento ósseo em relação à profundidade da linha marginal de cimentação de próteses sobre implantes Cone Morse: estudo experimental em cães / Histologic and histomorphometric evaluation of bone behavior in relation to the depth of the line of marginal cementation on Morse taper implants: experimental study in dogs

Stancari, Fernanda Herrera 18 May 2015 (has links)
A utilização dos implantes cone morse muito favorece a estética peri-implantar e seu uso em conjunto com próteses cimentadas favorece ainda mais a estabilidade do sistema, simplificando também os procedimentos protéticos. O presente estudo histológico e histomorfométrico utilizou os implantes cone morse com o intuito de avaliar o comportamento tecidual com relação à posição da margem da cimentação protética em relação ao tecido ósseo quando se faz o uso próteses cimentadas. Foram utilizados quatro cães, os quais tiveram todos os pré-molares inferiores extraídos numa primeira fase cirúrgica. Após três meses, realizou-se a segunda fase cirúrgica, na qual foi realizada a técnica da carga imediata, com a instalação dos implantes juntamente com os pilares protéticos. Foram instalados vinte e quatro implantes numa profundidade de 3 mm infra óssea e eles foram igualmente divididos entre os grupos Controle e Experimental. Os pilares protéticos utilizados foram do tipo munhão universal e apresentavam diferentes alturas transmucosas iguais a 1.5 mm, 3.5 mm, e 5.5 mm. Isto fez com que a margem da cimentação se posicionasse a 1.5 mm infra óssea, a 0.5 mm supra óssea e a 2.5 mm supra óssea. No grupo Controle, foi realizada a instalação dos implantes e dos pilares protéticos somente. No grupo Experimental, foi realizada a instalação dos implantes, dos pilares protéticos e, sobre estes, foram cimentados cilindros de alumina. Os animais permaneceram sobre controle de placa durante 10 semanas subsequentes a instalação dos implantes, sendo este o tempo final do experimento através da realização da eutanásia. As amostras foram preparadas para análise histológica e avaliação dos tecidos peri-implantares. A região de interesse foi medida através da distância entre a margem do pilar protético e a porção mais coronal da crista óssea peri-implantar. Foram utilizados os testes estatísticos ANOVA a três critérios com medidas repetidas e teste de Tukey com o nível de significância de p < 0.05. Os resultados mostraram que não houve diferenças estatisticamente significantes entre os grupos Controle e Experimental (p = 0.2764) e que os pilares de 1.5 mm mostram menos perda óssea comparada aos outros pilares, considerando que a distância média da remodelação óssea foi menor neste grupo (0.6859 mm) comparada com os pilares de 3.5 mm (1.2917 mm) e 5.5 mm (1.0823 mm). Conclui-se que não há influência da profundidade da margem da cimentação protética no comportamento da crista óssea e que a utilização de diferentes alturas dos pilares protéticos não parece alterar o tecido ósseo marginal ao redor dos implantes Cone Morse. / The use of Morse taper implants has increased because of some positive features. Cemented crowns can be extensively used, taking advantage of the system connection stability, also simplifying the prosthetic procedures. The present histological and histomorphometric study used Morse taper implants with the purpose of evaluating bone behavior with respect to the cementation margin position of the prosthetic crown. Four dogs had all premolars extracted at a first surgical procedure. After three months, there was a second surgical procedure with simultaneous installation of implants and abutments, submitted to immediate load. Twenty four implants were installed 3 mm below the bone level and they were equally divided between Control and Experimental groups. The universal post abutments used had three different transmucosal heights, 1.5 mm, 3.5 mm and 5.5 mm. Thus there were implants with the level of the cementation margin positioned 1.5 mm below the bone level, as well as 0.5 mm and 2.5 mm above the bone level. In the Control group, installation of implants and abutments only was performed. In the Experimental group immediately after the placement of implants and abutments alumina cylinders were cemented. The animals were kept on plaque control for 10 weeks after implant placement and then euthanized. Samples were prepared for histological analysis and evaluation of peri-implant tissues. The region of interest was measured by the distance between the prosthetic margin of the abutment to the most coronal peri-implant bone crest. ANOVA test at three criteria with repeated measures and Tukey test with a significance level of p < 0.05 were applied. The results showed no statistically significant differences between Control and Experimental groups (p = 0.2764). The 1.5 mm abutments presented less bone loss compared to all other abutments tested, because the distance average of bone remodelation was shorter in this group (0.6859 mm) compared to the 3.5 mm abutment (1.2917 mm) and the 5.5 mm one (1.0823 mm). Conclusion: There is no influence of the depth of prosthetic marginal cementation on the behavior of bone crest and the use of different transmucosal heights of abutments does not seem to change the marginal bone surrounding morse taper implants.
107

Análise clínica e de marcadores biológicos no fluido do sulco peri-implantar correlacionando-os à mucosa ceratinizada ao redor de implantes dentários / Clinical and biological markers analysis in peri-implant fluid and correlation with the keratinized mucosa around dental implants

Souza, Andréia Pereira de 10 February 2017 (has links)
Uma faixa adequada de mucosa ceratinizada (MC) é importante para garantir condições mínimas necessárias para o estabelecimento da homeostasia do periodonto de proteção. Frente à infecção bacteriana, os tecidos periodontais e peri-implantares desenvolvem uma resposta imune inflamatória local, resultando na produção e liberação de diversos mediadores inflamatórios que podem ser encontrados no fluido do sulco gengival e peri-implantar. Entretanto, é escassa a literatura acerca dos níveis desses mediadores em sítios peri-implantares considerando a faixa de MC. Assim, o objetivo deste trabalho foi avaliar a associação entre a quantidade e qualidade da MC peri-implantar e parâmetros clínicos e a qualidade da resposta imune através da análise da concentração de mediadores inflamatórios (IL-1, IL-4, IL-6, IL-8, MIP-1, TNF- e VEGF) presentes no fluido peri-implantar humano antes (T1) e depois (T2) da raspagem subgengival, através de imunoensaio. Parâmetros clínicos avaliaram índice de placa (IP), supuração a sondagem (S), profundidade de sondagem (mesial-PSM, centro-PSC e distal-PSD), índice de sangramento (mesial-ISM, centro-ISC e distal-ISD), nível de inserção relativo (NIR), largura (LMC) e espessura (EMC) da MC na face vestibular. Amostras de fluido sulcular foram coletadas e analisadas. Os implantes foram divididos em grupos de acordo com a faixa de MC (G12mm e G2>2mm) e espessura de MC (GA11mm e GB1>1mm; GA21,5mm e GB2>1,5mm). Foram avaliados 20 pacientes (11 homens e 9 mulheres) com idade entre 40 e 80 anos (53,45±10,32), que apresentaram 42 implantes (G1=25 e G2=17). Os resultados clínicos demonstraram diferença estatística significativa apenas entre T1 e T2 dentro do G1 para IP (T1=56% e T2=16%) e ISM (T1=68% e T2=40%). Foi observada diferença estatística entre G1 e G2 apenas para IL-1 em T2 (G1=9,77pg/ml±12,44 e G2=30,13pg/ml±32,29). Intra-grupos, todas as citocinas aumentaram significativamente, mas apenas no G2, demonstrando diferença de reatividade entre grupos. Quanto à espessura da MC (GA1=6 e GB1=36), resultados clínicos revelaram diferença inter-grupos para ISC em T2 (GA1=16,67% e GB1=61,11%) e intra-grupos para IP no GB1 (T1=52,78% e T2=27,78%). Houve aumento significativo no GB1 para todas as citocinas, exceto VEGF, assim como para IL-1 no GA1. Quando a amostra foi redistribuída em GA2=24 e GB2=18, os resultados clínicos indicaram diferença estatística inter-grupos para PSC em T2 (GA2=2,58mm±1,06 e GB2=3,11mm±1,02) e intra-grupos para IP (T1=62,5% e T2=20,83%) e PSC (T1=2,92mm±1,18 e T2=2,58mm±1,06) no GA2 e para ISM (T1=55,56% e T2=27,78%) no GB2. Intra-grupos observou-se aumento significativo para todas as citocinas no GA2 exceto VEGF, assim como IL-8 no GB2. Conclui-se que as diferenças clínicas apresentadas tenderam a evidenciar a importância da MC principalmente após o preparo inicial e, além disso, uma faixa de MC maior que 2mm influenciou os níveis dos mediadores inflamatórios avaliados após a raspagem subgengival. Adicionalmente, a falta de diferença estatística significativa na comparação entre grupos com diferentes espessuras de MC, bem como tal diferença ora no grupo espesso ora no grupo fino quando se adotam diferentes valores de corte (1mm ou 1,5mm respectivamente), demonstra resultados inconclusivos, ressaltando a importância de novas pesquisas para responder esta questão. / An adequate keratinized mucosa (KM) width is important to ensure minimal conditions necessary to establish protect periodontium homeostasis. When a bacterial infection occurs, periodontal and peri-implant tissues develop a local inflammatory immune response that results in production and release of several inflammatory mediators that may be found in gingival crevicular and in peri-implant fluids. However, there is a lack of literature concerning about the levels of these mediators in peri-implant sites considering KM width. The aim of this study was to evaluate the association between KM peri-implant quantity and quality and clinical parameters and immune response quality by analyzing the inflammatory mediators concentration (IL-1, IL-4, IL-6, IL-8, MIP-1, TNF- and VEGF) present in human peri-implant fluid before (T1) and after (T2) subgingival scaling, by immunoassay. Clinical parameters evaluated plate index (PI), probing suppuration (S), probing depth (mesial-PDM, center-PDC and distal-PDD), bleeding index (mesial-BIM, center-BIC and distal-BID), relative attachment level (RAL), keratinized mucosa width (KMW) and thickness (KMT) on the buccal face. Sulcular fluid samples were collected and analyzed. The implants were divided in groups according KM width (G12mm and G2>2mm) and KM thickness (GA11mm and GB1>1mm, GA21,5mm and GB2>1,5mm). Twenty patients (11 men and 9 women) aged 40 to 80 years (53,45±10,32) were evaluated, with 42 implants (G1=25 and G2=17). Clinical results showed a significant statistical difference only between T1 and T2 within G1 for PI (T1=56% and T2=16%) and BIM (T1=68% and T2=40%). Statistical difference was observed between G1 and G2 only for IL-1 in T2 (G1=9,77pg/ml±12,44 and G2=30,13pg/ml±32,29). Intra-groups, all cytokines increased significantly, but only in G2, showing reactivity difference between groups. As to KM thickness (GA1=6 and GB1=36), clinical results revealed intergroup differences for BIC in T2 (GA1=16,67% and GB1=61,11%) and intra-groups for PI in GB1 (T1=52,78% and T2=27,78%). There was a significant increase in GB1 for all cytokines except VEGF, as well as for IL-1 in GA1. When the sample was redistributed in GA2=24 and GB2=18, clinical results indicated statistical inter-group differences for PDC in T2 (GA2=2,58mm±1,06 and GB2=3,11mm±1,02) and intra-groups for PI (T1=62,5% and T2=20,83%) and PDC (T1=2,92mm±1,18 and T2=2,58mm±1,06) in GA2 and for BIM (T1=55,56% and T2=27,78%) in GB2. Intra-groups were observed significantly increase for all cytokines in GA2 except VEGF, as well as IL-8 in GB2. Concluded that clinical differences presented tended to show the KM importance principally after the initial preparation and, in addition, KM width greater than 2mm influenced the inflammatory mediators levels evaluated after subgingival scaling. Additionally, the absence of significant statistic difference between groups when comparing the keratinized mucosa thickness, as well as this difference sometimes in the thick group or in the thin group when different court values was adopted (1mm or 1,5mm respectively), show inconclusive results, emphasizing the importance of new research that may answer this question.
108

Avaliação da resistência à flexão de mini-implantes desenvolvidos para ancoragem esquelética do aparelho de Herbst - Estudo em Minipig br1 / Flexure resistance evaluation of mini implants prototypes developed for Herbst appliance anchorage Study in Minipig br1

Batista, Klaus Barretto dos Santos Lopes 23 April 2010 (has links)
Um efeito colateral indesejável do uso do aparelho de Herbst é a vestibularização excessiva dos incisivos inferiores que pode estar relacionada à retração gengival, à perda óssea marginal e à reabsorção radicular. A ancoragem esquelética do aparelho de Herbst poderia evitar estes problemas. O objetivo do presente estudo foi o de avaliar, em Minipigs br1, a resistência à flexão de protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst, comparar a resistência dos protótipos entre as duas regiões escolhidas para inserção e avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Após o cálculo do tamanho da amostra, 13 protótipos de mini-implantes foram colocados nas regiões posterior da maxila e anterior da mandíbula de três Minipigs br1, após terem sido mortos. Corpos de prova contendo os protótipos de mini-implantes inseridos em osso foram submetidos a uma força de flexão por engastamento simples utilizandose uma máquina universal de ensaios mecânicos Instron, calculando-se a média e o desvio padrão para cada região. Com o objetivo de comparar a resistência dos protótipos entre as regiões de inserção foi utilizado o Teste t de Student para duas amostras não pareadas. O teste de hipótese foi realizado para cada região para avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Para fins de comparação foram consideradas forças ortopédicas acima de 1,0 kgf. O nível de significância adotado foi P < 0,05. Os protótipos de miniimplantes apresentaram resistência à força de flexão de 13,86 kgf (DP = 2,3) para a região posterior da maxila e 20,55 kgf (DP = 5,2) para a região anterior da mandíbula. Houve diferença estatisticamente significativa entre as duas regiões com relação à força de resistência dos mini-implantes (P = 0,015), sendo que a resistência maior foi na região anterior da mandíbula. A hipótese de que os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas foi confirmada para as regiões posterior da maxila e anterior da mandíbula. Os autores concluíram que, em Minipigs br1, os protótipos de mini-implantes desenvolvidos para a ancoragem do aparelho de Herbst foram capazes de resistir a forças entre 13,86 e 20,55 kgf, sendo estatisticamente mais resistentes na região anterior da mandíbula e capazes de suportar forças ortopédicas. / An undesirable tooth movement resulting from use of the Herbst appliance is the excessive proclination of the anterior mandibular teeth, which is commonly associated with gingival recession, marginal bone loss, and root resorption. Skeletal anchorage of the Herbst appliance could prevent these problems. The present study was designed to evaluate, in Minipigs br1, the flexure resistance of prototype miniimplants developed for Herbst appliance anchorage, to compare the prototype resistance between the regions in which the mini-implants were placed, and to test the hypothesis that these mini-implant prototypes can withstand orthopedic forces. After calculation of sample size, 13 mini-implant prototypes (2 mm in diameter x 10 mm long) were inserted in the posterior region of the maxilla and the anterior region of the mandible, in three recently killed minipigs. The specimens were submitted to a single cantilever flexure test using an Instron testing machine. Mean and standard deviation were calculated for each region. To compare the resistance of the prototypes between the sites of mini-implant insertion, a 2-Sample Students t test was calculated. The test was carried out individually for each region, to evaluate if the prototype mini-implants developed for Herbst appliance anchorage could withstand orthopedic forces. Orthopedic forces above 1.0 kgf were considered. The level of significance was set at P < 0.05. The prototype mini-implant showed a flexure strength of 13.86 kgf (SD = 2.3) for the posterior region of the maxilla, and 20.55 kgf (SD = 5.2) for the anterior region of the mandible. A significant statistically difference was found in the resistance of the prototypes between the two regions (P = 0.015). The hypothesis that the prototype mini-implants can withstand orthopedic forces was confirmed. The authors concluded that, in Minipigs br1, the prototype mini-implants developed for Herbst appliance anchorage could resist forces from 13.86 to 20.55 kgf, were statistically more resistant in the anterior region of the mandible, and were capable of withstanding orthopedic forces.
109

Avaliação da resistência e módulo de elasticidade de osso mineralizado e desmineralizado pelos testes de microtração / Evaluation of the resistance and modulus of elasticity of bone mineralized and desmineralized for the tests of microtensile

Sanada, Jefferson Tomio 28 March 2007 (has links)
A perda do osso alveolar como resultado de doença periodontal ou secundariamente à cirurgia são fontes de inúmeras complicações para os cirurgiões dentistas, e a solução para tal problema se baseiam em procedimentos regenerativos. A regeneração é feita através de enxertos ósseos que estabelecem um arcabouço para a reparação tecidual, aumentando os tecidos ósseos nos defeitos resultantes de trauma ou cirurgias, preenchendo os alvéolos após extração para preservar a altura e espessura do rebordo alveolar e aumentando e/ou reconstruindo o rebordo alveolar. Estes procedimentos são realizados através da utilização de enxertos autógenos, alógenos, aloplásticos ou xenogênicos, tendo cada um suas características e indicações. Com o desenvolvimento dos implantes osseointegrados, viu-se a necessidade de manter uma boa quantidade e qualidade óssea. Este projeto tem como objetivo avaliar a resistência a tração e módulo de elasticidade do osso mineralizado e desmineralizado de calvária de ratos, a fim de determinar padrões iniciais (máximos e mínimos) para comparações com possíveis biomateriais de preenchimento de osteoindução e osteocondução. Foram utilizados 24 animais divididos em 2 grupos. O grupo 1 (n=12): módulo de elasticidade sendo que utilizaremos as duas parietais do animal, possibilitando 24 espécimes, subdividido em mineralizado (n=12) e desmineralizado (n=12). O grupo 2 (n=12): microtração, sendo que 12 hemicalvária foram utilizado para o sub-grupo desmineralizado e as outras 12 hemicalvária para o sub-grupo mineralizado. Após a morte dos animais, os espécimes serão coletados e tratados de acordo com o subgrupo (mineralizado e desmineralizado). Os testes foram realizados numa máquina de teste universal (Vitrodyme, V1000). As médias de resistência a tração do mineralizado foi 129,814 ± 34,921 MPa e o desmineralizado foi 18,547 ± 3,682 MPa. Para o módulo de elasticidade obtivemos os valores de 1377,792 ± 208,331 MPa para o grupo mineralizado e 49,669 ± 11,204 MPa para o grupo desmineralizado, ao compararmos o módulo de elasticidade e resistência a tração entre os subgrupo desmineralizado e mineralizado observa-se uma diferença estatisticamente significante para o grupo mineralizado (p<0,001). Conclui-se que o teste de microtração pode ser utilizado para avaliar as propriedades mecânicas nesse modelo experimental biológico. / The loss of the alveolar bone as resulted of periodontal illness or second to the surgery is sources of innumerable complications for the surgeons dentists, and the solution for such problem if it bases on regenerative procedures. Regeneration is made through bone grafts that establish one scaffold for the tecidual repairing, increasing bone fabrics in the resultant defects of trauma or surgeries, filling the alveolous after extraction to preserve the height and thickness of the alveolar rigde and being increased and/or reconstructing the alveolar rigde. These procedures are carried through the use of autogenous, alografts, aloplastic or xenogenics grafts, having each one its characteristics and indications. With the development of the osseointegrated implants, it was seen necessity to keep a good amount and bone quality. This project has as objective to evaluate the resistance the traction and modulus of elasticity of the mineralized bone and desmineralized.of calvarium of rats, similar to determine initial standards (maximum and minimum) for comparisons with possible biomateriais of fulfilling of osteoinduction and osteoconduction. 24 animals divided in 2 groups had been used. Group 1 (n=12): modulus of elasticity being that we will use the two parietals of the animal, having made possible 24 specimens, subdivided in mineralized (n=12) and desmineralized (n=12). Group 2 (n=12): microtraction, being that 12 hemi-calvarium had been used for 12 the desmineralized sub-group and the others hemi-calvarium for the mineralized sub-group. After the death of the animals, the specimens will be collected and treated in accordance with the sub-group (mineralized and desmineralized). The tests had been carried through in a machine of universal test (Vitrodyme, V1000). The resistance averages the traction of the mineralized one was mineralized 129,814 ± 34.921 MPa and the desmineralized one was 18,547 ± 3,682 MPa. For the modulus of elasticity we got values of 1377,792 ± 208.331 MPa for the mineralized group and 49,669 ± 11,204 MPa for the desmineralized group, when comparing the resistance and modulus of elasticity the traction between the desmineralized and mineralized sub-group observes a estatistical significant difference for the mineralized group (p<0,001). Concluded that the microtraction test can be used to evaluate the mechanical properties in this biological experimental model.
110

Avaliação de próteses metalocerâmicas unitárias implantossuportadas carregadas imediatamente na região posterior: estudo prospectivo de 6 meses / Evaluation of immediately loaded implant-supported metal ceramic crowns in the posterior region: prospective 6 months follow-up study

Machado, Camila Moreira 06 August 2018 (has links)
O objetivo deste estudo clínico prospectivo foi avaliar próteses metalocerâmicas unitárias implantossuportadas imediatamente carregadas na região posterior, instaladas com contato oclusal em máxima intercuspidação. Dezenove pacientes com perdas unitárias posteriores foram selecionados para receber implantes unitários imediatamente carregados com coroas metalocerâmicas. Todos os implantes foram inseridos com torque de inserção mínimo de 32 N.cm. e as coroas foram instaladas 4 dias após a instalação dos implantes. Os parâmetros avaliados foram: (1) sobrevida dos implantes, (2) tecido mole peri-implantar (índice de placa modificado - IPM, profundidade de sondagem - PS, índice de sangramento periimplantar - ISP e nível de inserção relativo - NIR) (3) prótese (Critério USPHS modificado), (4) avaliação radiográfica (perda óssea peri-implantar - POP) e (5) correlação do torque de inserção com perda óssea peri-implantar. Os períodos de avaliação foram: 9 dias (T1), 30 dias (T2) e 6 meses após a instalação do implante (T3). Concordância inter-examinadores (CIC) foi calculada para todos os parâmetros avaliados. A taxa de sucesso dos implantes foi de 100%; a taxa de sucesso da prótese foi de 89,5%, sendo observadas 2 complicações relacionadas com afrouxamento dos parafusos protéticos. As médias do IPM, PS, ISP NIR foram respectivamente: 0,21 ± 0,63, 1,71 ± 0,45, 0,53 ± 0,77, 10,56 ± 1,19, 1,54 ± 0,35 no tempo T2 e 0, 0, 1,36 ± 0,37, 10,55 ± 0,97 no tempo T3. Na comparação dos tempos, somente PS e ISP diminuíram significantemente de T2 para T3 (p = 0,006 e p = 0,015, respectivamente). As médias do nível ósseo peri-implantar nos tempos T1 e T3 foram de 1,54 ± 0,35 e 0,47 ± 0,76, respectivamente, com diferenças estatisticamente significantes encontradas entre os dois períodos de avaliação. CIC foi considerado excelente para todos os parâmetros avaliados ( 0,75). Dentro das limitações do estudo, os resultados sugerem que a carga imediata de implantes unitários posteriores restaurados com coroas metalocerâmicas com contato oclusal em máxima intercuspidação é uma opção viável de tratamento. Entretanto, pesquisas futuras devem ser conduzidas para a validação de tal protocolo a médio/longo prazos. / The purpose of this prospective clinical study was to evaluate implant-supported metal ceramic crowns immediately loaded in the posterior region, installed with occlusal contact at maximum intercuspation. Nineteen patients with posterior singleunit edentulous spaces were selected to receive implants immediately loaded with metal ceramic crowns. All implants were inserted with minimum insertion torque of 32 N.cm. and crowns were installed 4 days after implantation. The parameters evaluated were: (1) survival of the implants; (2) peri-implant soft tissue (modified plaque index - MPI and probing depth PD, peri-implant bleeding index PBI and relative insertion level RIL; (3) prostheses (modified USPHS criteria); (4) radiographic evaluation (peri-implant bone loss PBL) and (5) insertion torque correlation with peri-implant bone loss. The evaluation periods were: 9 days (T1), 30 days (T2) and 6 months after implant placement (T3). Inter-examiner agreement (IEA) was calculated for all parameters. The success rate of implants was 100%; the success rate of the prostheses was 89.5%, with 2 complications related to loosening of the prosthetic screws. The means of the MPI, PD, PBI, RIL were, respectively: 0.21 ± 0.63, 1.71 ± 0.45, 0.53 ± 0.77, 10.56 ± 1.19, 1.54 ± 0, 35 at T2 and 0, 0, 1.36 ± 0.37, 10.55 ± 0.97 at T3. In the comparison of evaluation time points, only PD and PBI decreased significantly from T2 to T3 (p = 0.006 and p = 0.015, respectively). Peri-implant bone level means at T1 and T3 times were: 1.54 ± 0.35 e 0.47 ± 0.76, respectively, with statistically significant differences between the two evaluation time points. IEA was considered excellent for all evaluated parameters ( 0,75). Within the limitations of the study, the results suggest that the immediate loading of posterior single implants restored with metal ceramic crowns with occlusal contact in maximal intercuspation is a viable treatment option. However, future research should be conducted to validate this protocol in the medium/long term.

Page generated in 0.0375 seconds