• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 11
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 739
  • 739
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea : estudo pelo método dos elementos finitos tridimensionais /

Antenucci, Rosse Mary Falcón. January 2011 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Pedro Yoshito Noritomi / Banca: Paulo Sérgio Perri de Carvalho / Banca: Fellippo Ramos Verri / Banca: Marcelo Ferraz Mesquita / Banca: Pedro Tortamano Neto / Resumo: Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below) / Doutor
382

Avaliação biomecânica de próteses unitárias sobre implantes de hexágono interno em maxila anterior com diferentes tipos de ancoragem óssea e comprimentos de implantes. Estudo pelo método dos elementos finitos 3-D. /

Cruz, Ronaldo Silva. January 2017 (has links)
Orientador: Fellippo Ramos Verri / Banca: Eduardo Piza Pellizzer / Banca: Joel Ferreira Santiago Junior / Resumo: Proposição: A proposta dessa pesquisa foi avaliar a distribuição de tensões em próteses unitárias implantossuportadas de hexágono interno (HI) na região maxilar anterior, variando a técnica de ancoragem óssea (Convencional (C), Bicorticalização (B) e Bicorticalização com elevação do assoalho nasal (BEAN) e as direções de carregamento (0°, 30° e 60°) por análise tridimensional (3D) de elementos finitos. Material e métodos: Três modelos tridimensionais foram simulados com ajuda dos programas Invesalius, Rhinoceros 3D 4.0 e SolidWorks 2011. Cada modelo possuía um bloco ósseo da região anterior do maxilar (osso tipo III) com 10m de altura padrão com um implante (4×8,5 mm (C), 4x10mm (B) e 4x11,5mm (BEAN), suportando uma coroa cimentada metal free. Os modelos foram processados pelos programas FEMAP v.11.0 e NEiNastran 11, utilizando uma força de 178 N em diferentes inclinações (0°, 30°, 60°). Os resultados foram plotados em mapas de tensão de von Mises (TvM), tensão máxima principal (TMxP), Microstrain (με) e Tendência de deslocamento (TD). Resultados: Análise de TvM mostrou aumento da concentração de tensão com o aumento da inclinação da força para os implantes, parafusos de fixação e abutments, com padrão similar de distribuição para os modelos testados. Sob análise de TMxP e με, o tecido ósseo apresentou maiores concentrações de tensões de tração sob cargas oblíquas (30° e 60°) ao redor do pescoço do implante na técnica convencional. Análise de deslocamento mostrou aumento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: CRUZ, R. S. Biomechanical evaluation of unitary prostheses on implants of internal hexagon in anterior maxilla with different types of bone anchorage and implant lengths. Study by the finite element method 3- D. 2017. Dissertation (Masters in Dental Science, Biomaterials concentration area) - Faculty of Dentistry of Araçatuba, Paulista State University, Araçatuba 2017. Proposition: The purpose of this research was to evaluate the stress distribution of single crowns supported by internal hexagon (HI) implants in the anterior region of the maxilla, varying the bone anchoring technique (conventional (C), bicorticalization (B) and bicorticalization with nasal floor elevation (BNFE) at loading directions (0°, 30° and 60°) by three-dimensional (3D) finite elemento analysis. Material and methods: Three 3D models were designed with aid of Invesalius, Rhinoceros 3D 4.0 and SolidWorks 2011 software. Each model contained a bone block of the premaxillary área (type III bone) with 10m of standard height with one implant (4×8, 5mm (C), 4x10mm (B) and 4x11.5mm (BNFE)), supporting a cemented metal free crown. The models were processed by the FEMAP v.11.0 and NEiNastran 11 using load of 178 N at different inclinations (0°, 30°, 60°). Von Mises (TvM), maximum principal stress (TMxP), microstrain (με) and displacement maps (D) were plotted to results analysis. Results: Analysis of TvM showed increased of stress concentration with increasing load inclination for implants, fixation screws and abtments, with similar pattern of distribution for the tested models. Under TMxP and με analysis, bone tissue showed higher traction stress concentrations under oblique loads (30 ° and 60 °) around the implant neck for the conventional technique. Displacement analysis showed increase of inclination tendency similar for all models ... (Complete abstract electronic access below) / Mestre
383

Comportamento biomecânico de implantes retos e angulados sobre cargas axiais e não axiais por análise de elementos finitos e extensometria linear /

Tribst, João Paulo Mendes. January 2017 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Alexandre Luiz Souto Borges / Banca: Francisley Ávila Souza / Resumo: Este trabalho buscou estudar as microdeformações geradas ao redor de implantes de hexágono externo durante carregamentos axiais e não axiais, variando-se a angulação dos implantes, utilizando a análise por elementos finitos e a extensometria linear como ferramentas. Inicialmente modelos 3D de diferentes próteses fixas foram construídos a fim de se permitir uma correlação dos resultados encontrados no modelo simplificado com o modelo anatômico e assim validar a geometria da prótese utilizada no estudo. Após a confirmação dos resultados de tensão similar entre as próteses na região dos implantes e do bloco, o modelo da prótese simplificada foi definida como válida. Em seguida, um modelo de bloco de poliuretano foi criado e duplicado. Implantes com conexão de hexágono externo (HE) foram modelados e em um bloco representados perpendiculares à superfície enquanto que em outro bloco foram colocados com inclinação de 17°. Foram modelados também intermediários do tipo mini pilar cônico retos e angulados conforme a inclinação dos implantes. Por último, foi utilizado o modelo de supraestrutura previamente validada para ambos os grupos, na qual a carga foi incidida. Todos os constituintes foram considerados perfeitamente simétricos, sólidos, isotrópicos. Os modelos receberam cargas de 300 N/cm em pontos axiais e não axiais através do software de análise por elementos finitos para se verificar a tensão máxima principal e as microdeformações. Em seguida, através da análise experimental de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:This Work aimed to study the microstrains generated around external hexagon implants during axial and non-axial loads, varying the angulation of the implants, using finite element analysis and linear strain gauge as tools. Initially 3D models of different fixed prostheses were constructed in order to allow a correlation of the results found in the simplified model with the anatomical model and thus validate the geometry of the prosthesis used in the study. After confirming the results of similar stress between the prostheses in the implants and the block region, the simplified prosthesis was defined as valid. After, a polyurethane block model was created and duplicated. Implants with external hexagon connection (HE) were modeled and inserted perpendiculary into one block while in another block, were placed with the inclination of 17 °. Straight and angled mini conical abutments were also modeled according to the inclination of the implants. Finally, the supra-structure previously validated for both groups was used, through which the load was affected. All constituents were considered perfectly symmetrical, solid, and isotropic. The models received a load of 300 N / cm in axial and non-axial points through the finite element analysis software, to verify the maximum principal stress and microstrains. Then, through the experimental analysis of strain-gauge, two polyurethane blocks were prepared and received three HE implants each, as well as respective mini tapered pillars according to the inclination of the installed implants. Then, a metallic superstructure, identical to the computational model, was cast in Ni-Cr and screwed onto the implants with torque of 10 N / cm. The load of 300 N / cm was applied for 10 seconds at axial and non-axial points. To measure the microstrains, four extensometers were glued on the surface of....(Resumo completo, clicar a acesso eletrônico abaixo) / Mestre
384

Corrosão e tribocorrosão de novas ligas Ti35Nb5Zr e Ti35Nb10Zr em saliva artificial /

Ribeiro, Ana Lúcia Roselino. January 2012 (has links)
Resumo: O sucesso dos implantes dentários em longo período depende da interação do biomaterial com o ambiente bucal, a qual envolve reações eletroquímicas, resistência mecânica e desgaste mecânico. Com o intuito de melhorar a resistência mecânica e à corrosão do titânio (Ti), elementos de liga são adicionados, sendo a liga Ti6Al4V a mais comum. Porém, o vanádio e o alumínio são considerados potencialmente tóxicos. Portanto, nos últimos anos, esforços vêm sendo feitos para o desenvolvimento de novas ligas de Ti ultra resistentes e biocompatíveis, a partir do sistema TiNbZr. Assim, o objetivo desse trabalho foi avaliar a corrosão e tribocorrosão das novas ligas Ti35Nb5Zr e Ti35Nb10Zr em saliva artificial a 37°C comparadas à liga comercial Ti6Al4V. Testes de potencial de circuito aberto com o tempo (Ecorr) e espectroscopia de impedância eletroquímica (EIS) foram realizados em função do tempo (0-216h). Testes de tribocorrosão em função de cargas aplicadas (50mN-1N) foram realizados tanto em Ecorr como em potencial anódico aplicado. Como resultados, todas as ligas exibiram aumento de Ecorr com o tempo, indicando crescimento e estabilização do filme passivo. Os experimentos de EIS indicaram que a liga Ti35Nb10Zr possui resistência à corrosão ligeiramente maior que a liga Ti6Al4V, assim como melhor comportamento tribocorrosivo quando realizado com baixa carga. Portanto, o filme passivo formado na liga Ti35Nb10Zr possui melhor resistência à corrosão e ao desgaste devido à presença de Nb2O5 e ZrO2. Porém, o metal base da liga Ti6Al4V apresentou menor desgaste mecânico. Concluindo, a liga de Ti35Nb10Zr é candidata promissora a ser utilizada na fabricação de conjuntos implantes-componentes protéticos. / Abstract: The long-life success of dental implants relies on the interaction between the biomaterial and oral environment, always involving electrochemical reactions, mechanical stresses and mechanical wear. In order to improve the mechanical strength and corrosion resistance of titanium (Ti), alloying elements are added to it, the most common alloy being Ti6Al4V. However, vanadium and aluminum are known to be toxic. Therefore, in last years, efforts are being made towards the development of new high resistant and biocompatible titanium alloys, namely from the TiNbZr system. Therefore, the aim of this work was to assess the corrosion and tribocorrosion behavior of new Ti35Nb5Zr and Ti35Nb10Zr in artificial saliva at 37°C, in comparison with the commercial Ti6Al4V alloy. Open circuit potential (Ecorr) and electrochemical impedance spectroscopy (EIS) experiments were carried in function of time (0-216h). Tribocorrosion tests were performed at different applied loads (50mN to 1N) both at Ecorr and anodic applied potential. In general, all alloys exhibited an increase of Ecorr with the immersion time, indicating the growth and stabilization of the passive film. The EIS results indicated that Ti35Nb10Zr alloy exhibited slightly better corrosion resistance than Ti6Al4V. Just as better tribocorrosion behavior at low applied loads. Therefore, the passive film formed on Ti35Nb10Zr alloy had better mechanical strength and corrosion resistance due to Nb2O5 e ZrO2. However, the bulk metal of Ti6Al4V suffered less mechanical wear. Concluding, Ti35Nb10Zr alloy appear as promising candidate for dental implant-abutment sets manufacturing. / Orientador: Luís Geraldo Vaz / Coorientador: Luís Augusto Sousa Marques da Rocha / Banca: Maria da Glória Chiarello de Mattos / Banca: Danilo Luiz Flumignan / Banca: Márcio Luiz dos Santos / Banca: Joni Augusto Cirelli / Doutor
385

Avaliação do efeito de centrifugado de medula óssea no processo de reparo ósseo ao redor de implantes instalados em tíbia de coelho : análise histológica e histométrica /

Betoni Júnior, Walter. January 2008 (has links)
Orientador: Pedro Felício Estrada Bernabé / Banca: Idelmo Rangel Garcia Júnior / Banca: Osvaldo Magro Filho / Banca: Vinicius Canavarros Palma / Banca: Ariel Lenharo / Resumo: O objetivo deste estudo experimental foi comparar histologicamente o reparo ósseo ao redor de implantes preenchidos por coágulo local com ou sem a associação de centrifugado de medula óssea, por meio de análises histológica e histométrica. Doze coelhos receberam dois implantes osseointegráveis em cada tíbia direita, onde a primeira cortical foi preparada com 5 mm e a segunda, ou cortical inferior, com 3 mm. Os implantes foram estabilizados na cortical inferior com 40 N, sendo um defeito preenchido por coagulo sanguíneo e o outro com coágulo e centrifugado de medula óssea. O sacrifício dos animais foi realizado nos períodos de 7, 21 e 60 dias. As peças foram submetidas a processamento laboratorial de rotina e coradas com vermelho de alizarina e azul de Stevenel. Tanto o grupo coágulo quanto o grupo coágulo e centrifugado de medula, após 60 dias, tiveram seus defeitos preenchidos por tecido ósseo, não apresentando diferença estatística entre os grupos quanto à extensão linear de contato entre tecido ósseo e implante. / Abstract: The objective of this experimental study was to compare histologically the bone repair around implant filled out by local coagulum with or without association of bone marrow centrifuged through histological and histometric analysis. Twelve rabbits received two implants in the right tibia, where the first cortical it was prepared with 5 mm and the second or lower cortical, with 3 mm. The implants were stabilized in lower cortical with 40 N, being one defect filled out by blood coagulum and the other filled out by blood coagulum and bone marrow centrifuged. The sacrifice of the animals was accomplished in the periods of 7, 21 and 60 days. The pieces were submitted to routine laboratorial process and stained with alizarin red and Stevenel's blue. Both groups had their defects filled by bone after 60 days, not presenting statistical difference between the groups about the linear extension of contact between bone tissue and implant. / Doutor
386

Osteogênese sobre titânio com nanotopografia /

Schwartz Filho, Humberto Osvaldo. January 2011 (has links)
Orientador: Resemary Adriana Chierici Marcantonio / Banca: Eduardo Hochuli Vieira / Banca: José Eduardo Cezar Sampaio / Banca: Fábio André dos santos / Banca: Sergio Luis Scombatti de Souza / Resumo: Os objetivos deste estudo foram avaliar a influência da nanotopografia de superfícies de titânio no processo de osteogênese por meio de avaliação histológica do contato osso-implante, em ratos, sob efeito da inalação forçada da fumaça de cigarro; Avaliar a osteogênese e a expressão de citocinas em cultura de células primárias sobre discos de titânio com nanotopografia; E avaliar o efeito morfológico e molecular da incorporação da laminina-1 (LN-1) em superfícies com nanotopografia, em coelhos. Implantes e discos de titânio foram especialmente produzidos e submetidos a diferentes métodos para a obtenção de superfícies: usinada, micro e nanotopografia. As superfícies foram devidamente caracterizadas quanto a sua topografia, morfologia e química. Os resultados mostraram que: a nanotopografia é capaz de aumentar o contato osso-implante (BIC) mesmo na presença da inalação intermitente da fumaça de cigarro, e foi capaz de reduzir, porem não totalmente, seus efeitos deletérios e uma menor formação óssea; A nanotopografia de titânio pode ter papel importante no processo de mineralização da matriz extracelular e na modulação da expressão de citocinas; E que a incorporação de LN-1 a superfície de titânio com nanotopografia demonstrou favorecer uma maior expressão de importantes genes envolvidos na cascata da osseointegração. / Abstract: The aims of this study were to evaluate the influence of nanotopography of titanium surfaces in the process of osteogenesis by means of histological assessment of bone-implant contact, in rats, under the effect of forced inhalation of cigarette smoke; To assess the osteogenesis process and the expression of cytokines in primary cell culture on titanium disks with nanotopography; And evaluate morphological and molecular the effect of incorporation of laminin-1 (LN-1) surfaces with nanotopography, in rabbits. Implants and titanium disks were specially produced and submitted to different methods for obtaining surfaces with turned, micro and nanotopography. The surfaces have been properly characterized as its topography, morphology and chemistry. The results showed that: nanotopography is able to increase bone-implant contact (BIC) even in the presence of intermittent inhalation of cigarette smoke, and was able to reduce, although not entirely, their harmful effects and a lower bone formation; Nanotopography may play a important role in mineralization process and in cytokine expression.; And the incorporation of LN-1 on titanium surface with nanotopography favor a higher expression of important genes involved in the cascade of osseointegration. / Doutor
387

Influência da carga oclusal parafuncional em próteses implantossuportadas, variando-se a proporção coroa/implante e o sistema de conexão protética : estudo pelo método dos elementos finitos tridimensionais /

Torcato, Leonardo Bueno. January 2013 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Marcelo Ferraz Mesquita / Banca: Fellippo Ramos Verri / Resumo: A condição de carga tem sido considerada o fator mais importante para a manutenção em longo-prazo da osseointegração e sucesso do tratamento reabilitador, portanto, é essencial otimizar a distribuição da carga mastigatória no complexo implante-coroa-parafuso. A proposta do presente estudo foi analisar, através do método dos elementos finitos tridimensionais, a influência do carregamento oclusal parafuncional, da proporção coroa/implante e da conexão protética (hexágono externo, hexágono interno e cone-morse) na distribuição das tensões em próteses unitárias implantossuportadas. Foram confeccionados cinco modelos tridimensionais com o auxílio de um scanner 3D MDX-20 e dos programas de modelagem gráfica: Rhinoceros 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks 2010 (SolidWorks Corp, Massachusetts, USA). Cada modelo foi composto por um bloco ósseo proveniente da região molar mandibular, por um implante dentário (Conexão Sistema de Prótese Ltda, São Paulo, Brasil) e por coroa metalocerâmica com diferentes alturas: 10, 12.5 e 15 mm. Os modelos tridimensionais foram exportados para o programa de elementos finitos FEMAP 10.1 (Noran Engineering, Inc., EUA), para estabelecimento das condições de contorno e geração da malha de elementos finitos. Aplicou-se uma carga funcional (200 N axial e 100 N oblíqua), bem como uma carga parafuncional (1000 N axial e 500 N oblíqua). A carga axial foi dividida em 4 pontos, localizados nas vertentes internas das cúspides, enquanto que a carga oblíqua foi dividida em 2 pontos, os quais localizaram-se nas vertentes internas das cúspides linguais. Os resultados foram visualizados por meio dos mapas de Tensão de von Mises e mapas de Tensão Máxima Principal. O carregamento parafuncional e o aumento da proporção coroa/implante induziram um aumento da área de distribuição e da magnitude das tensões no ... / Abstract: The load condition has been considered the most important factor for the long-term osseointegration maintenance and for the rehabilitation treatment success, then, it is essential to optimize the masticatory loading distribution on the implant-crown-screw complex. The purpose of this study was to analyze, through the 3D finite element method, the influence of parafunctional occlusal loading, the crown/implant ratio and the prosthetic connection (external hexagon, internal hexagon and morsetaper) on stress distribution in implant-supported single prostheses. Five 3D models were created with the aid of a 3D scanner MDX-20 and the graphical modeling softwares: Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks 2010 (SolidWorks Corp., Massachusetts , USA). Each model was composed of a bone block from the mandibular molar region, a dental implant (Conexão Sistema de Prótese Ltda, São Paulo, Brazil) and a metal-ceramic crown with different heights: 10, 12.5 and 15 mm. The 3D models were exported to the finite element software FEMAP 10.1 (Noran Engineering, Inc., USA) to have the boundary conditions established and the finite element meshes generated. A functional load (200 N axial and 100 N oblique) and a parafunctional load (1000 N axial and 500 N oblique) were applied on the occlusal surface of the crowns. The axial load was divided in four points located in the internal slope of the cusps, while the oblique load was divided into two spots, which were located in the internal slopes of the lingual cusps. The results were visualized through von Mises Stress and Maximum Principal Stress maps. The parafunctional load and the increased crown/implant ratio caused an increase in the distribution area and of the magnitude of the stresses in the implant (hexagon region, platform and first thread) and screw (neck). The conical internal connection ... / Mestre
388

Avaliação da precisão e distribuição de tensões em próteses fixas sobre implantes de hexágono externo obtidas por diferentes sistemas CAD-CAM /

Mello, Caroline Cantieri de. January 2017 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Fellippo Ramos Verri / Banca: José Vitor Quinelli Mazaro / Banca: Ricardo Alexandre Zavanelli / Banca: Joel Ferreira Santiago Junior / Resumo: Os sistemas CAD-CAM tem sido responsáveis por automatizar a produção odontológica, otimizando o tempo e tornando este processo cada vez mais viável. Objetivo: O objetivo deste trabalho foi mensurar as desadaptações marginais vertical (DMV) e horizontal positiva (DMHP) e negativa (DMHN) de PPF de zircônia confeccionadas por diferentes sistemas CAD-CAM e por um método convencional, e analisar pelo MEF-3D (método dos elementos finitos tridimensionais) a influência das desadaptações no comportamento biomecânico das estruturas protéticas. Além disso, confeccionar uma revisão sistemática e meta-análise comparando os estudos da literatura que tenham avaliado a desadaptação marginal de próteses e componentes protéticos implantossuportados confeccionados pelos sistemas CAD-CAM e pelo método convencional da fundição por cera perdida. Materiais e Métodos: Quarenta infraestruturas (n=10) foram confeccionadas (G1: Cerec Bluecam, G2: iTero, G3: 3Series, G4: Ni-Cr), e randomizadas para mensuração das desadaptações. Os resultados encontrados foram submetidos à análise de variância (ANOVA), com nível de significância à 5%. Os valores médios de DMV de cada grupo foram utilizados para a confecção de 6 modelos pelo MEF-3D, submetidos à aplicação de forças axiais e oblíquas. Os resultados foram visualizados através de mapas de tensão Von Mises. A revisão sistemática foi desenvolvida de acordo com o PRISMA e registrada na plataforma PROSPERO (CRD42017055685). Resultados: Os resultados ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: CAD - CAM systems in dentistry automate production, thus optimizing time and making the process even more convenient. Purpose : The aim of this study was to measure vertical (VMD) and positive (PHMD) and negative horizontal ( N HMD) marginal discrepancy of FPD frameworks made by different CAD - CAM systems (zirconia Y - TZP) and conventional method (cast), and to analyze by FEA - 3D the biomechanical performance of implant - prosthesis misfit. In addition, to do a systematic review and m eta - analysis comparing studies in the literature that have evaluated the marginal misfit of prostheses and implant - supported prosthetic components made by the CAD - CAM systems and the conventional method of lost - wax casting. Material and Methods: Forty fram eworks (n=10) were fabricated (G1: Cerec Bluecam, G2: iTero, G3: 3Series, G4: Ni - Cr ) and were randomized, to measure the misfits. The results were submitted to analysis of variance (ANOVA), with significance level at 5%. The average values of DMV of each g roup were used to make six models using FEA - 3D, applying axial and oblique loads. The results were analyzed using maps of Von Mises stresses, for each model. The systematic review was developed according to PRISMA statement and was register in the PROSPERO (International prospective register of systematic reviews) ( CRD42017055685). Results: The results of chapter 1 were: the conventional method showing the lowest values of vertical misfit compared to CAD - CAM systems (p<0.05). The CAD - CAM systems showing low est values of PHMD (p=0.014) and the conventional method did not present values of NHMD. In the biomechanical analysis, the oblique loading concentrated a greater amount of stresse s than the axial loading, in all situations evaluated. The fit models presen ted the most favorable biomechanical performance compared...(Complete abstract electronic access below) / Doutor
389

Efeito da altura da união implante/componente protético sobre os tecidos periimplantares: estudo clínico e radiográfico em cães

Paula, Wagner Nunes de [UNESP] 28 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-28Bitstream added on 2014-06-13T20:36:52Z : No. of bitstreams: 1 paula_wn_me_arafo.pdf: 549135 bytes, checksum: 1cd91d5b53b64bec46b8e5ace0efab34 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar as alterações dos tecidos periimplantares, ao redor de implantes instalados em diferentes profundidades em relação à crista óssea, e sob protocolos de reabilitação protética convencional e imediato. Cinco cães receberam trinta implantes, três por hemi-mandíbula (seis por cão), na região dos quatro pré-molares inferiores que foram extraídos 90 dias antes. Cada região foi divida pelos subgrupos convencional (protocolo convencional, instalação da prótese 120 dias após os implantes) e imediato (protocolo imediato, instalação da prótese 1 dia após a cirúrgia de implantes). Os implantes foram inseridos em três profundidades diferentes: ao nível (ao nível do rebordo ósseo), -1 mm (1 mm apicalmente à crista óssea) e -2 mm (2 mm apicalmente à crista óssea). Após acompanhamento por 45 dias da reabilitação instalada foi realizada avaliação clínica e radiográfica e, os dados foram analisados estatisticamente (p< 0.05). A posição do tecido marginal (PTM) não foi alterada pelo protocolo de instalação, e sim pelo nível de inserção da junção implante-conector protético (JIC) em relação a crista óssea (BC). A reabsorção da BC em função do nível de inserção de JIC foi relativamente uniforme para os diferentes grupos. Estes achados sugerem cautela ao posicionar a JIC de implantes apicalmente à BC. / The aim of the present study was to evaluate changes in tissues around dental implants inserted in different levels in relation to crestal bone (BC) under early and delayed loading conditions. Thirty implants were inserted in five mongrel dogs were used in this study, from which, the lower premolars were removed, and 90 days after, in one side, three dental implants were inserted (Delayed subgroup, implants installed 120 days before loading) in three different levels in relation to crestal bone (Bone Level, Minus1 and Minus2 groups), and three implants were inserted on remain ridge (Early subgroup, implants were loaded 48 hours after installed). The metallic prostheses were installed in both sides and preserved for 45 days. The clinical and radiographic analyses were performed. Data was submitted to statistics, under a 5% level of significance. The load conditions did not interfered on the position of marginal soft tissues (PTM), those changes evaluated because of the insert level of the implant-abutment junction (JIC) in to BC. The BC resorption was similar in all types of insertion levels of the implants. The present finds suggest caution on insertion of the implant in an apical position level in relation to BC.
390

Índice de sucessos de implantes osseointegráveis que receberam carga imediata unitária: avaliação clínica de curto período em humanos

Ribeiro, Fernando Salimon [UNESP] 27 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-27Bitstream added on 2014-06-13T20:57:38Z : No. of bitstreams: 1 ribeiro_fs_me_arafo.pdf: 126598 bytes, checksum: 8ba8de70ef22ae37dbd2b5dbe93ca194 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi comparar, em curto período de tempo, o índice de sucesso de implantes osseointegráveis unitários submetidos à carga imediata, colocados imediatamente após a exodontia, com implantes colocados em rebordos cicatrizados. Foram examinados 71 pacientes consecutivos totalizando 91 implantes, sendo 48 realizados em clínica privada e 43 em cursos de especialização em implantodontia, entre dezembro de 2001 a dezembro de 2003. Sessenta e três implantes foram instalados em alvéolos e 28 em rebordos. Os critérios utilizados para avaliar o índice de sucesso foram os descritos por Albrektsson e Zarb (1993). Após o período de avaliação, 87 implantes examinados enquadravam-se dentro dos critérios de sucesso (95,6%). Dos quatro implantes perdidos, três haviam sido colocados em alvéolos (índice de sucesso de 95,2%) e um, em rebordo (96,4%). A diferença entre os índices de sucesso dos dois grupos não foi estatisticamente significante (p=0,76, teste Qui-quadrado). Podemos concluir, dentro das limitações deste estudo, que o carregamento imediato de implantes unitários, seja colocado em alvéolo ou rebordo, representa uma alternativa terapêutica com alta previsibilidade, comparado aos resultados encontrados na literatura para implantes seguindo o protocolo convencional de dois estágios cirúrgicos. / The aim of this study was to evaluate, in a short period of time, the success rate of immediate loading of single-tooth implants: immediate versus non-immediate implantation. Seventy-one patients were examined, totalizing 91 implants, which 48 implants were placed in private practice office and 43 were placed in dental school, between December 2001 and December 2003. Sixty-one implants were placed in fresh extraction sites, and 28 were placed in healed sites. Criteria to evaluate success rate were previously described by Albrektsson and Zarb (1993). After follow-up evaluation, 87 implants fulfilled the success rate criteria (95,6%). Four implants were lost, and among these, three were placed in fresh extraction sites (success rate 95,2%), and one placed in healed sites (success rate 96,4%). Rates of success between both groups was not statistically significant (p=0,76, Qui-square test). Within the limitation of the present study, it could be concluded that single-tooth osteointegrated implants submitted to immediate loading, in immediate and non-immediate implantation, represent a therapeutic alternative with high predictability, compared to the conventional protocol.

Page generated in 0.0585 seconds