• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 10
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 738
  • 738
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Análise das tensões em próteses implantossuportadas esplintadas, variando o tipo de conexão protética e a inclinação do implante: estudo pelo método dos elementos finitos tridimensionais não linear

Almeida, Daniel Augusto de Faria [UNESP] 07 August 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-07. Added 1 bitstream(s) on 2016-02-05T18:34:24Z : No. of bitstreams: 1 000857939_20201231.pdf: 286758 bytes, checksum: af58a709e6c3ab93547da6b4ab0656b2 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, este estudo objetivou avaliar a influência da esplintagem e da inclinação de implantes (0º, 17º e 30º) em reabilitações de maxila posterior, na distribuição de tensões pelo método dos elementos finitos tridimensionais não linear. Para isso, foram confeccionados 12 modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Os modelos foram compostos por 3 implantes de hexágono externo (4,1 mm) ou cone morse (4,0 mm) nas regiões: 14 - 10 mm; 15 - 8,5 mm; 16 - 8,5 mm suportando próteses de 3 elementos unitárias ou esplintadas. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 400N axialmente e 200N obliquamente, divididas em cada cúspide das superfícies oclusais. Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho. Os resultados foram importados novamente ao FEMAP 10.2 para visualização e pós-processamento dos mapas de tensão de von Mises e tensão máxima principal. Os resultados... / The performance of an osseointegrated dental implant plays important rule for functional longevity of the rehabilitation. Sometimes, anatomical limitations imply in the positioning of tilted implants that is not considered ideal for prosthetic rehabilitation, generating higher stress concentration around it and leading to cortical bone resorption. To solve these situations, the professional must plan carefully the restoration and to study the connection type of the implant to better adaption for these situations. In this way, this study aimed to evaluate the influence of splinting prostheses and implant inclination (0º, 17º and 30º) in implant-supported prostheses in the posterior region of the maxilla on stress distribution by non-linear 3D finite element analysis. For this, twelve 3D models was confectioned using modeling software SolidWorks 2010 and Rhinoceros 4.0 and software InVesalius. The models constituted of 3 dental implants of external hexagon or morse taper (4,0 mm) at the regions: 14 - 10mm; 15 - 8,5 mm; 16 - 8,5 mm, supporting three-unit prostheses in single and splinting configurations. After modeling, the models were imported to pre- and post-processing software of finite elements FEMAP 10.2 for finite element mesh generation and configuration of restrictions and loading conditions. Axial load of 400N and oblique of 200N were applied divided on each cusp tip of occlusal surface. Next step, it was the analysis configuration on FEMAP 10.2 that was exported to NeiNastran 9.2 to math processing. After, the files of results were imported to FEMAP 10.2 to results visualization and post-processing analysis by plotting von Mises and maximum principal stress maps. The results of bone tissue showed higher stress concentration to inclined implants of external hexagon supporting single crowns under oblique loading. The models with splinted Morse taper... / FAPESP: 11/23884-6
352

Avaliação da influência de diferentes materiais oclusais na confecção de próteses fixas implantossuportadas unitárias com diferentes diâmetros dos implantes osseointegrados: estudo pelo método dos elementos finitos tridimensionais

Santiago Junior, Joel Ferreira [UNESP] 25 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-25Bitstream added on 2014-06-13T19:34:21Z : No. of bitstreams: 1 santiagojunior_jf_me_araca.pdf: 4599975 bytes, checksum: efdcd7bb205ee8146a6d5463f80ff100 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A literatura científica ainda é escassa em relação à influência de diferentes materiais na confecção de próteses fixas implantossuportadas unitárias em relação aos diferentes diâmetros dos implantes osseointegrados na distribuição das tensões; as suas manifestações e repercussões na prática clínica ainda não estão totalmente esclarecidas, sendo a fundamentação científica indispensável. Assim, o objetivo desta dissertação foi avaliar a influência do material de revestimento oclusal na confecção de prótese fixa implantossuportada unitária com diferentes diâmetros de implantes osseointegrados. Para o estudo foram elaborados 08 modelos, representando cada qual uma secção de osso mandibular (osso esponjoso e cortical), com a presença apenas de um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 10 mm (4 modelos) e de 5.00 mm x 10 mm (4 modelos) com coroas de porcelana feldspática, ou de resina acrílica, ou de resina composta ou coroa liga de NiCr. Para confecção dos modelos foram utilizados os programas de desenho assistido: Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEI Nastran® 9.0 (Noran Engineering, Inc, EUA), para geração da malha, aplicação da carga e análise. Os resultados foram visualizados através dos mapas de tensão von Mises de cada modelo proposto, a fim de avaliar as variações individuais da distribuição das tensões no implante e na coroa; no osso os resultados foram visualizados através dos mapas de tensão máxima principal. Na carga axial (200 N), o osso cortical não mostrou grandes diferenças entre todos os modelos e o osso trabecular sofreu um aumento das tensões por tração... / The scientific literature is still scarce about the influence of different veneering materials used in fabricating superstructures for implant-retained fixed prostheses in relation to different implant diameters on stress distribution, and the manifestations and implications in clinical practice were not clarified. The aim of this dissertation was to evaluate the influence of occlusal material for single implant-supported fixed prostheses with different implant diameters. For this study were simulated 8 models, representing a section of the mandibular bone (trabecular and cortical bone) with a single external hexagonal implant (Master Screw, Conexão Sistema de Prótese ltda., Sao Paulo, Brazil) of 3.75 x 10 mm (4 models) and 5.00 mm x10 mm (4 models) with a crown with different occlusal materials: feldspathic porcelain crowns, or acrylic resin or composite resin crown or NiCr alloy. The models were designed using computer-aided design softwares : Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp., Massachusetts, USA). The three-dimensional designs were exported to the finite element program NEI Nastran® 9.0 (Noran Engineering, Inc, USA) for mesh generation, load application and analysis. The results were visualized through von Mises stress maps of each model, to assess individual variations of the stress distribution on the implant and crown; bone results were visualized through maps of maximum principal stress. In axial loading (200 N), cortical bone showed no significant differences in all models,on the trabecular bone the tensile stress increased, with regular implant diameter. For non-axial loads (100 N), the cortical bone, the tensile stress increased significantly on the side common the load application, when it reduced the implant diameter; in the trabecular bone showed seemed stress patterns, although more... (Complete abstract click electronic access below)
353

Estudo de implantes de Ticp com superfícies modificadas por feixe de laser com e sem deposição química de apatitas: análises topográfica, biomecânica e histométrica em coelhos

Queiroz, Thallita Pereira [UNESP] 16 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-16Bitstream added on 2014-06-13T19:01:26Z : No. of bitstreams: 1 queiroz_tp_dr_araca.pdf: 6726778 bytes, checksum: 065d55c84b04f648183adf1b94784bd6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O sucesso da reabilitação com implantes osseointegráveis é dependente de vários fatores, destacando-se as propriedades físico-químicas da superfície, que interferem nas respostas biológicas e conseqüente reparo ósseo da interface osso/implante. O propósito deste estudo foi avaliar as superfícies de implantes de titânio comercialmente puro (Ticp) modificadas por feixe de laser (SL) sem e com deposição de hidroxiapatita pelo método biomimético, sem (SHAST) e com tratamento térmico (SHACT), comparando-as com implantes de superfície modificada por tratamento ácido (SA) e com superfície usinada (SU), empregando-se análises topográfica, biomecânica e histométrica. Quarenta e cinco coelhos receberam 150 implantes, sendo 2 implantes de cada superfície por tíbia. Após 30, 60 e 90 dias, os animais foram submetidos à eutanásia e os implantes localizados superiormente foram expostos, removidos por torque-reverso para análise biomecânica e as superfícies foram analisadas topograficamente. O implante localizado mais inferiormente em cada tíbia foi removido com o tecido ósseo ao redor e processado para obtenção de cortes histológicos não-descalcificados para análise histométrica da extensão linear de contato osso/implante (ELCOI) e da área óssea (AO) entre as espiras da região cortical superior. Aos 30 e 60 dias, os grupos SL, SHAST, SHACT e SA apresentaram valores de torque-reverso estatisticamente superiores (p<0,05) ao torque de SU. Aos 30 dias, os grupos SHAST e SHACT foram estatisticamente superiores ao grupo SA e o grupo SHAST foi superior ao SL. Aos 90 dias a diferença foi observada somente entre SHAST e SU. A análise topográfica revelou diferença estatística significante (p<0,05) entre a rugosidade de SL, SHAST e SHABT quando comparadas com SA e SU. A análise histométrica da ELCOI mostrou... / The success of rehabilitation with dental implants is dependent on several factors, highlighting the physical and chemical properties of the implant surface, which interfere with the biological responses and subsequent bone repair of bone-implant interface. The purpose of this study was to evaluate the surfaces of implants of commercially pure titanium (cp Ti) modified by laser beam (LS) with and without hydroxyapatite deposition by the biomimetic method, without (HAB) and with thermal treatment (HABT) comparing them with implants surface modified by treatment with acid (AS) and machined surface (MS), employing topographical, biomechanics and histometric analysis. Forty-five rabbits received 150 implants (2 implants of each surface in each tibia). After 30, 60 and 90 days, the animals were euthanized and the implants superiorly located were exposed, removed by removal torque for biomechanical analysis and the surfaces were examined topographically. The implant located more inferiorly in each tibia was removed with the bone tissue around and it was processed to obtain non-decalcified histological sections for histometric analysis of the percentage of bone-implant contact (BIC) and bone area (BA) between the threads of higher cortical. At 30 and 60 days, the groups LS, HAB, HABT and AS obtained removal torque values statistically superior (p <0.05) than the removal torque of MS. At 30 days, the HAB and HABT groups were statistically superior to the AS group and HAB was higher than LS. At 90 days, HAB was statistically significant different from MS. The topographical analysis showed statistically significant difference (p <0.05) between the roughness of LS, HAB and HABT when compared with AS and MS. The histometric analysis of BIC showed that LS, HAB and HABT were statistically superior to the AS and MS, in three... (Complete abstract click electronic access below)
354

Avaliação comparativa do processo de reparo do osso alógeno fresco congelado, em bloco, e do enxerto ósseo autógeno: análise histológica, histométrica e imunoistoquímica em coelhos

Garbin Júnior, Eleonor Álvaro [UNESP] 27 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-27Bitstream added on 2014-06-13T19:41:00Z : No. of bitstreams: 1 garbinjunior_ea_dr_araca.pdf: 1251895 bytes, checksum: 7b31a949d6b870eb13f7eecb1fdb04a6 (MD5) / Com a finalidade de recuperar rebordos alveolares atróficos para posterior reabilitação com implantes osseointegrados, além do enxerto ósseo autógeno, o osso alógeno fresco congelado recentemente tem sido empregado. O objetivo deste estudo foi analisar comparativamente o reparo dos enxertos ósseos autógenos e alógenos congelado em bloco, através de análise histológica, histométrica e imunoistoquímica em coelhos. Material e método: vinte um animais foram anestesiados para a realização da cirurgia experimental onde, na região de ângulo de mandíbula esquerdo foi fixado um bloco ósseo autógeno de 0,8 cm de diâmetro, utilizando-se parafuso, e no lado direito foi fixado, da mesma forma, um bloco ósseo tratado pelo Banco de Tecidos Músculo-Esquelético. Cinco animais de cada grupo foram sacrificados nos períodos de 15, 45, 120 e 180 dias. Os cortes histológicos foram corados pela hematoxilina e eosina e pela técnica de imunoistoquímica para avaliar atividades de reabsorção e neoformação óssea. Resultados: a análise histométrica mostrou não haver diferença estatística entre os grupos em relação à interface óssea leito receptor/enxerto ósseo aos 15 dias, contudo, analisando o bloco enxertado, notou-se maior revascularização, reabsorção e substituição óssea no grupo osso autógeno, fato este comprovado estatisticamente pela análise imunoistoquímica. Nos períodos tardios, o osso autógeno foi substituído em todas as amostras, enquanto no grupo do osso alógeno fresco congelado foi sempre possível encontrar osso desvitalizado junto ao parafuso de fixação. Conclusão: o processo de reparo apresentou maior dinâmica para o grupo enxerto ósseo autógeno em relação ao osso alógeno fresco congelado. A substituição do enxerto autógeno foi completa enquanto... / The autogenous bone graft and the freeze allogenic bone graft have being used to reconstruct atrophic alveolar ridge to allow the use of osteointegrated implants rehabilitation. The aim of this study was to compare the healing process of autogenous and allogenic bone graft using the histological, histometrical, imunoistochemical analyses in rabts. Material and Methods: twenty one animals had surgery done to allow fixation of 0.8 cm diameter of autogenous tibia bone graft on the left mandibular angle, and allogenic tibia bone graft on the right madibular angle. Five animals from each group were sacrificed at 15, 45, 120, and 180 postoperative days. The histological cuts were stained by hematoxilin and eosin and imunohistochemical technique to evaluate the bone formation and resorption. Results: the histometric analyses of bone formation betweem the bone graft interface and mandibular bone showed no statistical difference on the 15 days, but, the graft surface evaluation showed more revascularization, resorption and bone formation on the autogenous bone graft group and it was confirmed statiscialy by the imunoistochemical analyses. On the lastest groups (120 and 180 postoperative days), the autogenous bone was totally replaced but on the allogenic group it was possible to find non vital bone next to the fixation screw. Conclusion: the bone repair showed more dynamic activity on the autogenous graft group and it was totally replaced. The allogenic graft was incorporated but, on the latest sacrificed groups, it was not totally replaced.
355

Avaliação do efeito de centrifugado de medula óssea no processo de reparo ósseo ao redor de implantes instalados em tíbia de coelho: análise histológica e histométrica

Betoni Júnior, Walter [UNESP] 25 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-25Bitstream added on 2014-06-13T19:20:07Z : No. of bitstreams: 1 betonijunior_w_dr_araca.pdf: 635815 bytes, checksum: 15db5b7ed9b94b7320e3bc5833b5133e (MD5) / O objetivo deste estudo experimental foi comparar histologicamente o reparo ósseo ao redor de implantes preenchidos por coágulo local com ou sem a associação de centrifugado de medula óssea, por meio de análises histológica e histométrica. Doze coelhos receberam dois implantes osseointegráveis em cada tíbia direita, onde a primeira cortical foi preparada com 5 mm e a segunda, ou cortical inferior, com 3 mm. Os implantes foram estabilizados na cortical inferior com 40 N, sendo um defeito preenchido por coagulo sanguíneo e o outro com coágulo e centrifugado de medula óssea. O sacrifício dos animais foi realizado nos períodos de 7, 21 e 60 dias. As peças foram submetidas a processamento laboratorial de rotina e coradas com vermelho de alizarina e azul de Stevenel. Tanto o grupo coágulo quanto o grupo coágulo e centrifugado de medula, após 60 dias, tiveram seus defeitos preenchidos por tecido ósseo, não apresentando diferença estatística entre os grupos quanto à extensão linear de contato entre tecido ósseo e implante. / The objective of this experimental study was to compare histologically the bone repair around implant filled out by local coagulum with or without association of bone marrow centrifuged through histological and histometric analysis. Twelve rabbits received two implants in the right tibia, where the first cortical it was prepared with 5 mm and the second or lower cortical, with 3 mm. The implants were stabilized in lower cortical with 40 N, being one defect filled out by blood coagulum and the other filled out by blood coagulum and bone marrow centrifuged. The sacrifice of the animals was accomplished in the periods of 7, 21 and 60 days. The pieces were submitted to routine laboratorial process and stained with alizarin red and Stevenel’s blue. Both groups had their defects filled by bone after 60 days, not presenting statistical difference between the groups about the linear extension of contact between bone tissue and implant.
356

Avaliação da osseointegração promovida por implantes jateados por Al2O3: análises histológica e histométrica em cães

Ponzoni, Daniela [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:41:00Z : No. of bitstreams: 1 ponzoni_d_dr_araca.pdf: 781446 bytes, checksum: 6716157527edd6e5ca653e94715b65fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A formação de uma interface osseointegrada é mais previsível quando osso denso e saudável está em contato com a superfície do implante no momento da instalação. Porém, a colocação de implantes imediatos após exodontia apresenta inúmeras vantagens, entre elas a preservação da arquitetura óssea e gengival dos processos alveolares, além da diminuição do tempo cirúrgico. A utilização de uma superfície modificada proporciona um maior contato ósseo com o implante; baseado em princípios biológicos. A proposta deste trabalho é avaliar qualitativa e quantitativamente a interface entre osso e os implantes de titânio, jateados por Al2O3 instalados imediatamente após exodontias, em cães. Os implantes foram instalados nos alvéolos de pré-molares mandibulares bilateralmente em quatro cães. Foram instalados quatro implantes para cada animal (4mm de diâmetro e 10mm de comprimento) do Sistema Colosso (Emfils®), sendo dois de cada lado da mandíbula. Os animais foram sacrificados aos 120 dias pós-operatórios. As peças foram desmineralizadas, e os implantes removidos. Três implantes foram perdidos, três fibrointegrados e dez osseointegrados. A análise quantitativa foi realizada considerando-se cinco roscas apicais e o fundo do implante. A análise histológica mostrou tecido ósseo saudável em fase de maturação em íntimo contato com os implantes osseointegrados. Na análise histométrica, observou-se um contato ósseo de 76% nos implantes osseointegrados. / An osseointegrated interface could be predictable when dense and healthy bone is in contact with the titanium implant surface at the moment of implant insertion. However, immediate implantation after exodontia presents numerous advantages, among them, maintenance of bone and gingival architecture and decrease of operative time. The use of an implant with modified surface favors bone contact, according to biological principles. This study aims to evaluate the interface between bone and Al2O3 blasted titanium implants installed in 4 dogs immediately after bilateral exodontias of mandibular premolars. Four Emfils® implants (Sistema Colosso - 4mm diameter; 10mm length), 2 per side, were used in each dog. Animals were sacrificed after 120 days of surgery and the samples removed. Bone was decalcified and the implants removed. Three implants were lost, 3 had fibrointegration and 10 osseointegrated. Histological analysis showed a healthy tissue in process of maturation interfacing osseointegrated implants. Quantitative analysis was focused in 5 apical threads and the bottom of the implants. It was shown a contact of 76% between bone and the implants. Osseointegration was achieved around Al2O3 blasted titanium implants installed immediately after exodontias.
357

Membrana reabsorvível com enxerto ósseo autógeno ou BoneCeramic em rebordos atróficos em implante de titânio: estudo histométrico em cães

Hayacibara, Roberto Masayuki [UNESP] 26 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-26Bitstream added on 2014-06-13T21:04:27Z : No. of bitstreams: 1 hayacibara_rm_dr_araca.pdf: 434924 bytes, checksum: c828c6276d51f994ba5eee35c4019f18 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Propósito: O objetivo deste estudo foi avaliar histometricamente as alterações ósseas dimensionais, que ocorrem em rebordo atróficos induzidos experimentalmente, com a colocação de implante e enxerto ósseo autógeno ou grânulos de hidroxiapatita/fosfato β-tricálcio (BC) associados à membrana reabsorvível (MR). Materiais e Métodos: Defeitos ósseos foram criados após a extração dos 3 e 4 pré-molares mandibulares de cinco cães beagle. Após 3 meses, foram colocados 2 implantes em cada lado da mandíbula, dentro do rebordo atrófico, resultando em aproximadamente 6mm de superfície exposta do implante. Três grupos de tratamento foram distribuídos aleatoriamente: sem tratamento, MR + Osso autógeno (OA), MR + grânulos de hidroxiapatita/fosfato β-tricálcio. Após 4 meses, os cães foram sacrificados e foi realizada análise histométrica para avaliação de contato osso implante (COI) e ganho ósseo vertical (GOV). As médias de COI e GOV dos três grupos foram comparadas pelo teste de Tukey ao nível de significância de 5%. Resultados: Em 4 meses, o tratamento com MR+OA mostrou COI (%): 26.41 ± 4.90 e GOV (%): 16.06 ± 11.83. O grupo com MR+BC obteve COI (%): 15.16 ± 2.40 e GOV (%): 7.45 ± 9.84 e o grupo A mostrou COI (%): -0.23 ± 0.50 e GOV (%): -1.09 ± 8.99. O grupo MR+OA mostrou regeneração óssea maior (COI e GOV) que o grupo MR+BC e o grupo A (p<0.05). O grupo MR+BC obteve regeneração óssea maior (COI) que o grupo A (p<0.05). Conclusão: Concluiu-se que em rebordos atróficos: (i) tratamento com MR+OA aumenta a regeneração óssea, incluindo ganho ósseo vertical e contato osso implante; (ii) ocorre perda óssea na ausência de técnicas regenerativas / Purpose: The objective of this study was to evaluate histometric bone dimensional changes that occur in atrophics defects induced experimentally by placing the implant and autogenous bone graft or hydroxyapatite/β-tricalcium phosphate granules (BC) associated with reabsorbable membrane (RM). Material and Methods: A defect was created after the extraction of three four mandibular premolars of five beagle dogs. After 3 months, 2 implants were placed on each side of the mandible, within the atrophics defects, resulting in approximately 6 mm exposed surface of the implant. Three treatment groups were randomly assigned to: untreated control, RM + autogenous bone, RM + hydroxyapatite /β-tricalcium phosphate granules. After four months, the dogs were sacrificed and histometric analysis was performed to evaluate bone implant contact (BIC) and vertical bone gain (VBG). Mean BIC and VBG in the three groups were compared by Tukey test at a significance level of 5%. Results: In 4 months, treatment with RM + autogenous bone showed BIC (%): 26.41 ± 4.90 and VBG (%): 16.06 ± 11.83. The group RM + BC showed BIC (%): 15.16 ± 2.40 and VBG (%): 7.45 ± 9.84 and the A group obtained BIC (%): -0.23 ± 0.50 and VBG (%): - 1.09 ± 8.99. The RM + autogenous bone group showed greater bone regeneration (BIC and VBG) that RM + BC group and A group (p <0.05). The group received RM + BC greater bone regeneration (BIC) than the A group (p <0.05). Conclusion: We conclude that in atrophics defects: (i) RM + autogenous bone treatment increases bone regeneration, including vertical bone gain and bone implant contact, (ii) bone loss occurs in the absence of regenerative techniques
358

Avaliação da incorporação de enxertos ósseos homógenos em humanos: análises histológica e imunoistoquímica

Abla, Marcelo Sabbag [UNESP] 27 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-27Bitstream added on 2014-06-13T19:22:10Z : No. of bitstreams: 1 abla_ms_dr_araca.pdf: 493211 bytes, checksum: 7b996be2b8e49d11e130d4903e67a50b (MD5) / O osso homógeno fresco congelado tem sido utilizado no intuito de substituir o osso autógeno. No entanto as suas propriedades de osteoindução e até mesmo osteocondução não estão bem conceituadas na literatura científica. Esse trabalho teve por objetivo avaliar amostras de tecido ósseo homógeno enxertados em humanos através das análises qualitativas histológica e imunoistoquímica. Para tal, dez pacientes previamente selecionados foram submetidos à cirurgia de reconstrução de defeitos ósseos em espessura, usando enxerto ósseo homógeno em bloco fresco congelado estabilizado e fixado por meio de parafusos bicorticais. Após período de integração de seia meses foi realizado procedimento de reabertura para instalação dos implantes osseointegráveis. Neste momento cirúrgico, amostras do enxerto ósseo foram removidas por meio de broca trefina. As amostras foram fixadas em formol 10%, levadas ao processamento para corte descalcificado em parafina e coradas por hematoxilina e eosina. Realizou-se processamento imunoistoquímico para a expressão da enzima Caspase 3. As lâminas foram levadas à microscopia óptica para realização das análises histológica e imunoistoquímica qualitativas. Os resultados mostraram tecido ósseo não vital, com poucas áreas de deposição de osso neoformado sobre a matriz amorfa, presença de infiltrado inflamatório com áreas de osteomielite e imunomarcação expressiva da enzima Caspase 3. Diante da metodologia empregada e dos resultados obtidos concluiu-se que o enxerto homógeno apresentou somente a propriedade biológica de osteocondução durante a fase de incorporação de seis meses / Allogeneic bone has been used fresh frozen in order to replace bone autograft. However, the properties of osteoinduction and osteoconduction are not even well-regarded in the scientific literature. This work aimed to evaluate samples of homogenous bone grafts in humans by qualitative histological analysis and immunohistochemistry. For this ten pre-selected patients underwent surgical reconstruction of bone defects in thick, homogenous bone graft using fresh frozen block stabilized and fixed by bicortical screws. After integration period of six months reopening procedure was performed for installation of osseointegrated implants. At this surgical time bone graft samples were removed by means of drill trephine. The samples were fixed in formalin 10%, taken to court for processing decalcified paraffin, and stained with hematoxylin and eosin. Immunohistochemistry was performed processing for the expression of the enzyme Caspase 3. The slides were brought to light microscopy to carry out the qualitative histology and immunohistochemistry. The results showed non-vital bone tissue, with few areas of deposition of new bone formation on the amorphous matrix, presence of chronic inflammatory infiltrate with areas of osteomyelitis, and immunostaining expressive of the enzyme Caspase 3. Given the methods employed and the results obtained it was concluded that the graft showed only a homogenous biological property of osteoconduction, during the incorporation of six months
359

Avaliação da influência da osteoporose induzida em ratas, e seu tratamento com alendronato e estrógeno, sobre o tecido ósseo ao redor de implantes

Giro, Gabriela [UNESP] 17 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-17Bitstream added on 2014-06-13T19:22:56Z : No. of bitstreams: 1 giro_g_dr_arafo.pdf: 2606543 bytes, checksum: ec3040a973d9fcf21be5856e46e14736 (MD5) / O presente projeto teve como objetivo avaliar a influência da deficiência de estrógeno, e as implicações dos tratamentos com alendronato e estrógeno, sobre o tecido ósseo ao redor de implantes. Para isso foram realizados dois estudos distintos, visando elucidar as questões em torno desse tema. No primeiro estudo, foram utilizadas ratas Wistar, com idade aproximada de 60 dias, submetidas à colocação de um implante na metáfise tibial com o objetivo de avaliar a influência da deficiência estrogênica e dos tratamentos com alendronato e estrógeno sobre o tecido ósseo em implantes que já se encontravam osseointegrados. Os resultados mostraram efeitos deletérios da referida deficiência, com diminuição da força de torque necessária para remoção dos implantes, menor quantidade de osso em contato com a superfície e área de osso entre as roscas, aumento nos marcadores de remodelação óssea e menor taxa de aposição mineral no período avaliado. Por outro lado, os animais que receberam a administração do alendronato apresentaram os melhores resultados para todas as análises realizadas, apesar do tecido ósseo mostrar-se mais compacto e sem sinais de remodelação. Concluiu-se que a deficiência estrogênica decorrente da ovariectomia (OVX) acarretou alterações sistêmicas, como perda de massa óssea, e alterou as características do tecido ósseo ao redor dos implantes. Esse quadro pôde ser revertido com os tratamentos instituídos, tendo o alendronato apresentado os melhores resultados. O segundo estudo visou avaliar os efeitos da deficiência de estrógeno e de diferentes dosagens de alendronato, sobre implantes instalados na maxila de ratas e, portanto, sob influência da carga mastigatória. Nesse estudo foram avaliadas também as implicações da instalação de implantes em animais que estavam sob terapia... / This study aimed the evaluation of the influence of bone mass loss and its therapies on bone tissue around osseointegrated implants. For that reason two major projects were conducted. First of all, two implants were placed in 66 female rats tibiae. The animals were assigned to 5 groups: control (CTL), sham, ovariectomy (OVX), oestrogen (EST) and alendronate (ALE). While CTL was sacrificed 60 days after implant placement, other groups were subjected to ovariectomy or sham surgery according to group and euthanized after 90 days. Blood and urine samples were collected at sacrifice day for osteocalcin and deoxypyridinoline quantification. Densitometry of femur and lumbar vertebrae were performed in order to evaluate rats’ skeletal impairment. One implant was subjected to the removal torque test, while the remaining one was referred to non-decalcified sections and analysed by fluorescent and light microscopy for analyses of mineral apposition rate (MAR), eroded and osteoclastic surfaces, bone to implant contact (BIC), and bone area fraction occupancy (BAFO). The results of this study showed that OVX presented significantly lower values for all parameters analysed compared to other groups. ALE increased bone mineral density and the removal torque of the implants, but also reduced osteocalcin and deoxypyridinoline concentrations, MAR, osteoclastic and eroded surfaces, and no difference was in BIC and BAFO relative to SHAM. EST and CTL showed similar results to SHAM for measurements. The results lead the authors to conclude that oestrogen deficiency exerted a negative influence on bone tissue around implants, while oestrogen replacement therapy and alendronate were effective against its effects. Although alendronate therapy maintained the amount of bone tissue around implants, studies evaluating bone turnover kinetics ... (Complete abstract, click electronic access below)
360

Biocompatibilidade in vitro em amostras densas e porosas de titânio-35nióbio submetidas a tratamento biomimético

Andrade, Dennia Perez de [UNESP] 29 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-29Bitstream added on 2014-06-13T19:23:22Z : No. of bitstreams: 1 andrade_dp_dr_sjc.pdf: 981103 bytes, checksum: 368bc6b13475a5629a9213ad35edf3ea (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Titânio (Ti) é um dos melhores biomateriais para a confecção de implantes cirúrgicos, porém, estudos com novas ligas de Ti e variações da topografia visam otimizar os resultados da osseointegração. O objetivo deste estudo in vitro foi avaliar a biocompatibilidade de amostras densas e porosas da liga titânio- 35nióbio submetidas ou não ao tratamento biomimético, comparadas a amostras de Ti puro grau 2. As amostras foram divididas em 6 grupos (G): a) G1- Ti denso; b) G2 - Ti poroso; c) G3 – Ti poroso tratado; d) G4 - Ti-35Nb denso; e) G5 - Ti-35Nb poroso; f) G6 - Ti-35Nb poroso tratado. Células osteogênicas obtidas da calvária de ratos recémnascidos foram plaqueadas sobre as amostras e a adesão celular foi avaliada após 4 e 24 horas, enquanto a proliferação celular foi avaliada em 1, 3, 7 e 10 dias. A viabilidade foi avaliada em 1, 3, 7 e 10 dias. Para os demais testes as células foram cultivadas por 7, 10 e 14 dias. Após 14 dias, as culturas foram coradas com vermelho de Alizarina S para detecção dos nódulos de mineralização. As amostras foram caracterizadas por espectroscopia por dispersão de energia (EDS), difração de raio X (DRX), análise metalográfica e de rugosidade. Os dados da análise metalográfica foram submetidos ao teste de Kruskal Wallis e os dados das análises celulares foram comparados pelos testes Kruskal Wallis, Mann-Whitney e T-Student, (p<0,05). O EDS demonstrou a presença de íons sódio, fósforo, magnésio e cálcio nas amostras tratadas de ambos os grupos. O DRX demonstrou a presença dos metais titânio e nióbio na liga teste. A análise metalográfica demonstrou que as amostras porosas apresentavam poros interligados, com morfologia variada e a análise pelo rugosímetro demonstrou... / Titanium (Ti) is one of the best biomaterials for surgical implants fabrication. Studies with new titanium alloys and varied surface topographies seek for improved osseointegration results. The aim of the present in vitro study was to evaluate dense and porous titanium- 35 niobium alloys, submitted or not to biomimetic treatment in comparison to degree 2 pure titanium specimens. Specimens were divided into 6 groups (G): a) G1 – dense Ti; b) G2 – porous Ti; c) G3 – treated porous Ti; d) G4 – dense Ti-35Nb; e) G5 – porous Ti-35Nb and f) G6 – treated porous Ti-35Nb. Osteogenic cells from newborn rats calvarium were plated over the samples and cell adhesion assessed after 4 and 24 hours. Cell proliferation and viability were assessed at 1, 3, 7 and 10 days. Cells were cultured for 7, 10 and 14 days for further testings. Cell cultures were stained with Alizarin Red S after 14 days for mineralization nodules detection. Specimens were characterized by means of Energy Dispersion Spectrophotometry (EDS), X-Ray Diffraction (XRD), metallographic and profilometer analyses. Metallographic data were submitted to Kruskal Wallis, while cell analyses were assessed with Kruskal Wallis, Mann-Whitney and T-Student tests (P<0.05). EDS results detected the presence of sodium, phosphor, magnesium and calcium ions in treated specimens from both groups. XRD showed the presence of titanium and niobium for the test alloy. Metallographic analysis revealed interconnected pores and varied morphology within the porous specimens. Greater rugosity was detected by the profilometer analysis within the dense alloy specimens. In vitro tests revealed similar biocompatibility of Ti- 35Nb and degree 2 pure Ti. Porosity did not interfere, but in some scenarios improved alloy biocompatibility. The biomimetic treatment favor greater production... (Complete abstract click electronic access below)

Page generated in 0.2135 seconds