• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 10
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 738
  • 738
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Efeitos da radioterapia na obtenção da osseointegração em ratos / Effects of radiotherapy in obtaining osseointegration in rats

Kamezawa, Leonardo Silva Gomes 11 December 2017 (has links)
Submitted by Leonardo Silva Gomes null (drleonardosgomes@gmail.com) on 2018-01-22T00:28:55Z No. of bitstreams: 1 Dissertação corrigida.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-01-23T19:48:52Z (GMT) No. of bitstreams: 1 kamezawa_lsg_me_sjc.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) / Made available in DSpace on 2018-01-23T19:48:52Z (GMT). No. of bitstreams: 1 kamezawa_lsg_me_sjc.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) Previous issue date: 2017-12-11 / A radioterapia é o uso da aplicação de radiação ionizante em áreas específicas, visando tratamento de tumores. Porém, a área irradiada e os tecidos normais circundantes estão sujeitos a danos agudos e crônicos. As injúrias no tecido ósseo variam desde osteopenia até osteorradionecrose e, devido a estas alterações, pacientes irradiados portadores de implantes vêm demonstrando maior taxa de insucesso. O objetivo deste estudo foi avaliar os efeitos da radioterapia, simulando uma dose total de um tratamento radioterápico convencional para pacientes oncológicos, na neoformação óssea e na osseointegração de implantes em fêmures de ratos. Foram utilizados neste estudo 66 ratos que receberam implantes cilíndricos de titânio comercialmente puro (TiCp) nos fêmures direito e esquerdo. Os animais foram divididos em 3 grupos: a) Grupo controle (C): cirurgia de colocação dos implantes (tecido sadio sem irradiação); b) Grupo irradiação precoce (Ip): cirurgia de colocação dos implantes seguido de irradiação após 24h; c) Grupo irradiado (I): irradiação e após 4 semanas, cirurgia de colocação dos implantes. Os animais dos grupos Ip e I foram submetidos a irradiação em 02 sessões de 15 Gy, totalizando a dose de 30 Gy. Os animais foram eutanasiados nos períodos de 2 e 7 semanas após o tratamento. Durante o experimento, os animais foram cuidadosamente monitorados quanto as alterações clínicas. Em cada período, 06 animais foram submetidos à análise histomorfométrica, visando avaliar a neoformação óssea e a interface osso-implante. Os outros 05 animais, dos períodos de 2 e 7 semanas após o tratamento, foram submetidos ao teste de torque reverso para avaliar a força de fixação osso-implante, obtida na osseointegração. Todos os dados foram estatisticamente analisados por meio da análise de variância de 2 fatores para torque reverso, porcentagem de área de formação óssea (BAFO) e porcentagem de superfície de contato osso implante (BIC) com nível de significância a 5%. O teste de Tukey foi realizado para determinação dos grupos homogêneos. A irradiação ionizante influenciou negativamente de maneira estatisticamente significante, retardando o processo de osseointegração, porém, não sendo capaz de inibí-lo. / The radiotherapy is ionizing radiation proceeding in specific areas, aiming at the treatment of tumors. However, the irradiated area and the surrounding normal tissue can develop acute and chronic damage. In bone tissue, injuries ranging from osteopenia to osteroadionecrosis and due to these changes patients irradiated with implants have shown higher failure rate. The objective of this study was to evaluate the effects of radiation, simulating a total dose of a conventional radiotherapy treatment for cancer, bone regeneration and osseointegration of implants in femurs of rats. It was used in this study 66 mice that receive cylindrical implants of commercially pure titanium (cpTi) on the right and left femurs. The animals were divided into 3 groups: a) control group (C): implant placement surgery (control group - healthy tissue without irradiation); b) Group early irradiation (Ip): placement of implants surgery followed by radiation after 24h; c) Group irradiated (I): irradiation and after 4 weeks of surgery implant placement. The animals of the Ip and I groups were subjected to irradiation in a double step at a dose of 15 Gy each, totalizing dose of 30 Gy. The animals were euthanized at periods of 2 and 7 weeks after treatment. During the experiment, the animals were carefully monitored for clinical changes. In each period 06 animals were submitted to histomorphometric analysis, to evaluate the bone formation and boneimplant interface. The other 05 animals, in periods of 2 and 7 weeks after treatment, were submitted to the reverse switch test to evaluate the strength of bone-implant fixation, obtained in osseointegration. All data were statistically analyzed by means of the 2-factor variance analysis for reverse torque, percentage of bone area fraction occupancy (BAFO) and percentage of bone implant contact (BIC) with significance level at 5%. The Tukey test was performed to determine the homogeneous groups. The ionizing radiation influenced negatively in a statistically significant way, delaying the process of osseointegration, but not being able to inhibit it.
332

Influência do tipo de fundição e uso de retificação na interface pilar/cilindro protético na adaptação marginal e tensão peri-implantar sobre conexão protética tipo Micro-Unit

Gonçalves, Marianna Cavalheiro [UNESP] 24 September 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-09-24Bitstream added on 2014-06-13T20:37:52Z : No. of bitstreams: 1 goncalves_mc_me_sjc.pdf: 588689 bytes, checksum: bc38a4736e89f0a9df85bafce423c010 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo neste estudo foi avaliar, in vitro, a adaptação marginal por meio da microscopia óptica, de cilindros pré-fabricados de Co-Cr comparados com cilindros calcináveis fundidos em Ni-Cr pelo método convencional e pela fundição por indução, com e sem o uso de retificadores e analisar por meio da extensometria a tensão ao redor do implante gerada com o uso destes componentes parafusados sobre os pilares tipo Micro-Unit. Foram utilizados 36 cilindros tipo Micro-Unit subdivididos em 3 grupos: G1 (controle) - 12 cilindros pré-fabricados de Co-Cr; G2 - 12 cilindros calcináveis fundidos pelo método convencional em liga de níquel-cromo (Ni-Cr); G3 - 12 cilindros calcináveis fundidos pelo método de indução em liga de Ni-Cr. Para todos grupos foram realizadas as leituras no microscópio óptico com um aumento de 200 vezes e realizada a mensuração da tensão pela extensometria. Na análise microscópica foram realizadas quatro leituras para cada face do octógono no qual o implante estava instalado. A extensometria foi realizada durante o aperto do parafuso, com torquímetro eletrônico, do cilindro em questão após o implante estar devidamente posicionado sobre o aparato que garantia que o torque era gerado sem nenhuma influencia do operador. Posteriormente, os cilindros dos grupos 2 e 3 foram retificados formando dois sub-grupos: G2b e G3b, os quais foram novamente analisados em microscópio óptico e na extensometria. Os valores de média e desvio padrão encontrados na desadaptação marginal nos grupos foram:... / The main point of this study was to evaluate, in vitro, the marginal misfit using the optical microscopy Co-Cr cylinders prefabricated compared with abutment cylinders cast in Ni-Cr conventional casting and by induction, with and without use of rectifiers and analyzed with strain gages around the implant generated with the use of these components bolted on the Micro-Unit abutments. 36 micro-unit cylinders were divided into 3 groups: G1 (control) - 12-pre-fabricated Co-Cr cylinders, G2 - 12 cylinders copings cast with conventional nickel-chromium (Ni-Cr)alloy, G3 - 12 cylinders copings cast method of induction in the Ni-Cr. For all groups were performed measurements at optical microscope with an increase of 200 times (200x) and performed the strain gages measurement. In the microscopic analysis were performed four readings for each side of the octagon in which the implant was installed. The gage was carried out during tightening of the screw with an electronic torque wrench drum in question after the implant to be properly positioned on the apparatus that guarantees that the torque was generated without any influence of the operator. Thereafter, the cylinders in groups 2 and 3 were rectified to form two sub-groups: G3B and G2b, which were further, analyzed using an optical microscope and the strain gages. The mean value and standard deviation found in the marginal discrepancy in the groups were: ... (Complete abstract click electronic access below)
333

Avaliação da influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões: estudo pelo método dos elementos finitos tridimensionais

Almeida, Daniel Augusto de Faria [UNESP] 21 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-21Bitstream added on 2014-06-13T19:58:21Z : No. of bitstreams: 1 almeida_daf_me_araca.pdf: 686399 bytes, checksum: 50ad249856d1640af8c25dd2dcb4adb5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento e uso de intermediários angulados, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, o propósito do presente estudo foi analisar a influência da angulação dos implantes com diferentes tipos de conexão protética na distribuição de tensões, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados seis modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco ósseo e a presença de um implante (4,0x10 mm) com diferentes angulações (0º, 17º e 30º) e tipos de conexão (Hexágono externo e cone morse), com coroa metalo-cerâmica. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (quatro para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho... / The biomechanical behavior of an osseointegrated dental implant plays an important role in the longevity. The anatomical limitations sometimes require the placement of implants with angles outside the considered ideal for prosthetic rehabilitation, with higher stress concentration and resorption in cortical bone around the implant. Thus, in some situations, the professional should planning careful the treatment and use the abutment, analyzing the prosthetic connection which best fits the clinical situation. Therefore, the purpose of this study was to analyze the influence of the implant angulation with different types of prosthetic connection on the stress distribution, by three-dimensional finite element method. Six three-dimensional models were made with the aid of the graphical modeling and SolidWorks 2010 Rhinoceros 4.0 and InVesalius.Each model was composed of a bone blockwith an implant (4.0 x 10 mm) with different angulations (0, 17 and 30) and connection types (Hexagon external and Morse taper) with metal-ceramic crown. After generation of the geometries, the models were imported into the pre-and post-processing finite element FEMAP 10.2, where we generated finite element meshes, boundary and loading conditions. The load was applied axial 200N and 100N obliquely to the occlusal surface of crowns. This total load was divided between the cusps (four for the axial load and two oblique lingual to the load). Then, the analysis was generated in and exported 10.2 FEMAP software for calculation in finite element program NeiNastran version 9.2, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and maximum principal stress. The maps for... (Complete abstract click electronic access below)
334

Influência da carga oclusal parafuncional em próteses implantossuportadas, variando-se a proporção coroa/implante e o sistema de conexão protética: estudo pelo método dos elementos finitos tridimensionais

Torcato, Leonardo Bueno [UNESP] 05 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-05Bitstream added on 2014-06-13T19:58:23Z : No. of bitstreams: 1 000738205.pdf: 11748078 bytes, checksum: f498d70af73bd4b59e43f830c28ec206 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A condição de carga tem sido considerada o fator mais importante para a manutenção em longo-prazo da osseointegração e sucesso do tratamento reabilitador, portanto, é essencial otimizar a distribuição da carga mastigatória no complexo implante-coroa-parafuso. A proposta do presente estudo foi analisar, através do método dos elementos finitos tridimensionais, a influência do carregamento oclusal parafuncional, da proporção coroa/implante e da conexão protética (hexágono externo, hexágono interno e cone-morse) na distribuição das tensões em próteses unitárias implantossuportadas. Foram confeccionados cinco modelos tridimensionais com o auxílio de um scanner 3D MDX-20 e dos programas de modelagem gráfica: Rhinoceros 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks 2010 (SolidWorks Corp, Massachusetts, USA). Cada modelo foi composto por um bloco ósseo proveniente da região molar mandibular, por um implante dentário (Conexão Sistema de Prótese Ltda, São Paulo, Brasil) e por coroa metalocerâmica com diferentes alturas: 10, 12.5 e 15 mm. Os modelos tridimensionais foram exportados para o programa de elementos finitos FEMAP 10.1 (Noran Engineering, Inc., EUA), para estabelecimento das condições de contorno e geração da malha de elementos finitos. Aplicou-se uma carga funcional (200 N axial e 100 N oblíqua), bem como uma carga parafuncional (1000 N axial e 500 N oblíqua). A carga axial foi dividida em 4 pontos, localizados nas vertentes internas das cúspides, enquanto que a carga oblíqua foi dividida em 2 pontos, os quais localizaram-se nas vertentes internas das cúspides linguais. Os resultados foram visualizados por meio dos mapas de Tensão de von Mises e mapas de Tensão Máxima Principal. O carregamento parafuncional e o aumento da proporção coroa/implante induziram um aumento da área de distribuição e da magnitude das tensões no... / The load condition has been considered the most important factor for the long-term osseointegration maintenance and for the rehabilitation treatment success, then, it is essential to optimize the masticatory loading distribution on the implant-crown-screw complex. The purpose of this study was to analyze, through the 3D finite element method, the influence of parafunctional occlusal loading, the crown/implant ratio and the prosthetic connection (external hexagon, internal hexagon and morsetaper) on stress distribution in implant-supported single prostheses. Five 3D models were created with the aid of a 3D scanner MDX-20 and the graphical modeling softwares: Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks 2010 (SolidWorks Corp., Massachusetts , USA). Each model was composed of a bone block from the mandibular molar region, a dental implant (Conexão Sistema de Prótese Ltda, São Paulo, Brazil) and a metal-ceramic crown with different heights: 10, 12.5 and 15 mm. The 3D models were exported to the finite element software FEMAP 10.1 (Noran Engineering, Inc., USA) to have the boundary conditions established and the finite element meshes generated. A functional load (200 N axial and 100 N oblique) and a parafunctional load (1000 N axial and 500 N oblique) were applied on the occlusal surface of the crowns. The axial load was divided in four points located in the internal slope of the cusps, while the oblique load was divided into two spots, which were located in the internal slopes of the lingual cusps. The results were visualized through von Mises Stress and Maximum Principal Stress maps. The parafunctional load and the increased crown/implant ratio caused an increase in the distribution area and of the magnitude of the stresses in the implant (hexagon region, platform and first thread) and screw (neck). The conical internal connection ...
335

Avaliação da influência da inclinação das cúspides e da direção das cargas oclusais na distribuição das tensões em próteses implanto-suportadas: estudo através do método dos elementos finitos tridimensionais

Antenucci, Rosse Mary Falcón [UNESP] 31 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-31Bitstream added on 2014-06-13T18:58:13Z : No. of bitstreams: 1 antenucci_rmf_me_araca.pdf: 2213262 bytes, checksum: b726ffb6f49b3b045219b744f81c80b9 (MD5) / Apesar do uso do implante dental ser um procedimento clínico largamente utilizado, não esta isento de complicações mecânicas, que podem produzir falha nas próteses ou nos implantes. Portanto, é essencial otimizar a distribuição da carga mastigatória através das próteses e destas para os implantes e osso suporte. O propósito do presente estudo foi realizar uma análise pelo método dos elementos finitos tridimensionais para avaliar a influência da inclinação das cúspides e direção das cargas oclusais na distribuição das tensões em próteses implanto-suportadas. Foram elaborados 5 modelos mandibulares com o auxilio dos programas de desenho assistido Rhinoceros® 3D 3.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA) e com o auxílio de um scanner 3D MDX-20 (Roland DG, São Paulo, Brasil); por meio destes simularam-se um bloco de osso mandibular (osso cortical e osso esponjoso), com a presença de um implante unitário de 3,75x10 mm (Conexão Master Screw, São Paulo, Brasil) com coroa metalo-cerâmica com 3 diferentes inclinações das cúspides (10°, 20° e 30°). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEiNastran® 9.0 (Noran Engineering, Inc., EUA), para determinação das regiões, incorporação das propriedades de cada material, geração da malha e análise. Foi aplicada uma carga oblíqua (45°) de 200 N, fracionada em 2 pontos (100 N) nas vertentes triturantes das cúspides vestibulares da coroa metalo-cerâmica e posteriormente uma carga axial (0°) de 200 N, distribuida em 4 pontos (50 N) nas v ertentes internas da coroa metalo-cerâmica. Os resultados foram visualizados por meio dos mapas de tensão de von Mises e mostraram que os valores mais altos de tensão para o implante foram no modelo de 30° de in clinação das cúspides... / Although, osseointegrated implant is a clinical procedure longer used. It is not trouble-free. Therefore, is essential optimizing the occlusal loading through the prostheses to implants and supporting bone. A Threedimensional (3D) finite element analysis was performed to evaluate the influence of cuspal inclination and occlusal loading direction on stress distribution in implant-supported prostheses. Three-dimensional finite element models were simulated by means of Rhinoceros® 3D 3.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA) programs and the scanner 3D MDX-20 (Roland DG, São Paulo, Brazil). A mandibular section of bone with an implant and its superstructures were simulated in this study. A 1-piece 3.75 x 10 mm screw-shape (Conexão Master Screw, São Paulo, Brazil) dental implant system, embedded in trabecular bone with 1 mm of cortical bone surrounding and crown with 3 different cuspal inclinations (10°, 20° and 30°). Three-dimensional models were transferred to the NEiNastran® 9.0 (Noran Engineering, Incorporation, USA.) software, in which, material properties were incorporated and mesh and analysis generated. Oblique loading (200 N) was applied on chewing surfaces of buccal cuspid. After, vertical loading (200 N) was applied on internal surfaces of the cuspids. According to the results, it was observed, higher stress values was showed in the model with 30° of c uspal inclination; in cortical bone the higher stress was showed in the model with 10° of cuspal inclination. Oblique and axial loading produce maximum stress concentrations at the point of load application. It was concluded that: An increasing in the cuspal inclination increased stress in the osseointegrated implant and decreased the stress in cortical bone and Oblique loading increased the general stress in 100% in relation to axial loading.
336

Influência das variáveis morfológicas em modelos fotoelásticos com implantes submetidos à carga axial

Silva, Cristina Ramos da [UNESP] 06 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-06Bitstream added on 2014-06-13T20:18:39Z : No. of bitstreams: 1 silva_cr_me_araca.pdf: 1526600 bytes, checksum: 974b60587fa9ef9081e6506ff887d371 (MD5) / Este trabalho teve como objetivo analisar, em 12 modelos fotoelásticos, com alturas e espessuras diferentes, se a aplicação de uma força axial de 100N sobre os implantes resultaria em alteração na morfologia da reflexão fotoelástica. Na análise fotoelástica, os modelos foram colocados em um Polariscópio para a observação das franjas isocromáticas. A formação destas franjas se fez pela aplicação de uma carga axial de 100N, dirigida ao ponto central do cicatrizador posicionado sobre o implante medindo 10mm x 3,75mm (Conexão, Sistemas de Próteses, Brasil). A tensão resultante de cada modelo fotoelástico foi monitorada e registrada fotograficamente e, subsequentemente vista através do programa gráfico Phothoshop 7.0. Para análise qualitativa, foi mensurada a área abaixo do ápice do implante, envolvendo a faixa verde da franja de segunda ordem de cada modelo através do programa Image Tool. A partir da confrontação do tamanho dessas áreas, definiu-se a performance gerada por cada corpo de prova, frente à carga axial aplicada. Resultados: houve alteração do tamanho da área analisada quando variaram a altura e a espessura dos modelos fotoelásticos. Observamos que quando os modelos foram observados em grupo, o grupo III (altura de 30mm) apresentou menor área. Significância: a morfologia do corpo de prova pode influenciar de forma direta no resultado de pesquisas com modelos fotoelásticos e isto pode levar à 16 interpretações incorretas, portanto, não se pode comparar resultado de corpo de prova com tamanhos e formas diferentes. / This study aimed to analyze in 12 photoelastics models with heights and different thicknesses if the application of an axial force of 100N on implants result in changes in the morphology of photoelastic reflection. For the photoelastic analysis the models were placed in a reflection polariscope for the observation of fringes patterns isochromatics. The formation of these fringes was done by applying an axial load of 100 N, addressed to the central point of healed positioned on the implant measuring 10mm x 3.75 mm (Conexão, Sistemas de Próteses - Brasil). The tension resulting from each photoelastic model was monitored and recorded photographically and subsequently seen through the chart Phothoshop 7.0. For qualitative analysis measured the area below the apex of the implant involving and the fringe of the green belt of the second order of each model through the Image Tool. From the comparison of the size of these areas we define the performance generated by each body of evidence, at the axial load applied. We can see that change in the size of the listening area where several analyzed height and thickness of the models under study. Results: There was variation in the size of the area where several analyzed height and thickness of the photoelastics models. We observed that when the models were observed in group, group III (height 30mm) showed a lower area. Significance: The morphology of the samples can to influence an important role in the direct result of research with photoelastic models and this can lead to 19 incorrect interpretations, so we can not compare the result of samples with different size and shape.
337

Análise fotoelástica da distribuição de tensões em próteses implantossuportadas cimentadas ou parafusadas em implantes de hexágono externo, interno ou cone-morse

Tonella, Bianca Piccolotto [UNESP] 27 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-27Bitstream added on 2014-06-13T20:58:52Z : No. of bitstreams: 1 tonella_bp_me_araca.pdf: 2631898 bytes, checksum: e7d82ae183b139909ee981ffa14e2112 (MD5) / Os aspectos biomecânicos do implante osseointegrado são fundamentalmente diferentes daqueles do dente natural, que é circundado pelo ligamento periodontal. A possibilidade de transferência de sobrecarga ao implante, e deste ao osso, pode exceder o limite fisiológico e provocar falha da reabilitação ou até mesmo a perda da osseointegração. Portanto, é essencial otimizar a distribuição da carga mastigatória através das próteses e destas para os implantes e osso suporte. A avaliação biomecânica da geometria do implante e do sistema de retenção protético torna-se fundamental, visto que os implantes foram desenvolvidos para suportarem forças durante sua função. O estudo das tensões entre as estruturas de suporte e implantes tem sido realizado para prevenir falhas da estrutura protética ou do próprio implante. Assim, nosso trabalho teve como objetivo a realização de dois capítulos, sendo que o primeiro capítulo analisa a distribuição das tensões nos diferentes tipos de implantes, hexágono externo, hexágono interno e cone-morse, em relação aos sistemas de retenção protética, parafusadas ou cimentadas, em próteses parciais fixas implantossuportadas de três elementos. O segundo capítulo aborda a distribuição de tensões nas próteses parciais fixas implantossuportadas unitárias e de três elementos, usando implantes de hexágono externo, interno e cone-morse. Foram construídos modelos fotoelásticos em resina PL-2 (Vishay Measurements Group, Inc Raleigh, N.C. USA), com implantes de 4,00 x 10 mm (Conexão Sistema de Prótese Ltda- São Paulo- SP - Brasil). A saber foram construídos para: 1) próteses parciais fixas implantossuportadas de três elementos com dois implantes, situados na região segundo pré-molar e segundo molar, e 2) modelos com implantes unitários. As próteses foram construídas de forma padronizada... / The biomechanical aspects of an implant are fundamentally different from those of a natural tooth, which is surrounded by a periodontal ligament. The possibility of transferring the overload to the implant, and then to the bone, may exceed the physiological limit and cause failure of rehabilitation or even loss of osseointegration. Therefore, it is essential to optimize the distribution of the chewing load through the prostheses and from them to the implants and support bone. The biomechanical evaluation of the implant’s geometry and prosthetic retained system becomes essential, since the implants were developed to withstand forces during their function. The study of the stress between the structures of support and implants have been done to prevent failures of the prosthesis structure or of the implant. Thus, our work aimed at the achievement of two studies, being the first chapter the analysis of stress distribution on different types of implants: external hexagon, internal hexagon and morse taper, compared to retained prosthesis systems: screwed and cemented in 3-FDP. The second chapter discusses the distribution of stress between dental implant single tooth and 3-FDP, taking into account the different types of connection of the implant. Photoelastic models were built in PL-2 resin (Vishay Measurements Group, Inc Raleigh, NC USA) with 4.00 x 10 mm implants (Conexao Sistema de Protese Ltda- Sao Paulo- SP - Brazil). Models were built for: 1.) fixed partial dentures of three elements with two implants, located in the second pre-molar and on the region of the second molar, and 2) models with dental implants single tooth. The prostheses were constructed in a standardized way with Ni-Cr alloy (Fit Cast-SB Plus - without Beryllium, Talladium do Brasil, Curitiba-PR-Brazil). A circular polariscopy was used and a Universal Testing Machine (EMIC DL-3000) applied axial... (Complete abstract click electronic access below)
338

Avaliação da formação óssea em implantes dentários de ratos não diabéticos, diabéticos não controlados e controlados com insulina /

Souza, Augusto César Rodrigues de. January 2011 (has links)
Resumo: O diabetes mellitus é considerado hoje, um problema de saúde pública mundial. Na odontologia está associado à doença periodontal, aumentando as chances de perda do elemento dental nos pacientes diabéticos. Implantes dentários são cada vez mais utilizados em pacientes parcialmente ou totalmente edêntulos para reposição dessas perdas. Estudos experimentais, para viabilizar o tratamento dentário de diabéticos através de implantes são cada vez mais freqüentes. Dada a relevância do tema, ainda existem lacunas no estudo da osseointegração de implantes em animais diabéticos. Por isso, visando dar sequência a esses estudos experimentais já existentes, esse estudo foi delineado para avaliação da osseointegração de implantes dentários em animais normais, diabéticos e diabéticos tratados com insulina, utilizando parâmetros adicionais nunca antes avaliados. O presente estudo teve como objetivo avaliar a formação óssea ao redor de implantes dentários em ratos diabéticos aloxânicos controlados com insulina, em relação a ratos não diabéticos e diabéticos não controlados. Foram avaliados 72 ratos da raça Wistar, machos, sadios ao exame clínico, pesando entre 200 e 300g, distribuídos em três grupos experimentais de 24 animais cada, sendo um grupo controle normal (GC), um grupo diabético sem tratamento (GD) e um grupo diabético tratado com insulina (GI). Os animais receberam os implantes dentários no fêmur direito e foram avaliados em três momentos pós-operatórios (7º, 14º e 21ºdias), onde foram analisadas a evolução clínica (peso corporal e diurese), exames laboratoriais (glicemia de jejum, hemoglobina glicosilada e insulina sérica). Em cada um dos momentos mencionados os animais foram sacrificados e retirado o fêmur com o implante, sendo espécimes de 4 animais utilizados para análise ultraestrutural das fibras colágenas, à microscopia... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Diabetes mellitus is nowadays a public health problem worldwide. In dentistry is associated with periodontal disease, increasing the possibilities of tooth loss in diabetic patients. Dental implants are been commonly used in patients partially or completely edentulous to replace these losses. Experimental studies, to enable the dental treatment of diabetics through implants are becoming more frequent. Despite the relevance of the issue , there are still gaps in the study of osseointegration of implants in diabetic animals . Therefore, in order to fulfill some of these questions, this study was designed to evaluate the osseointegration of dental implants in normal, diabetic and diabetic treated with insulin animals, using additional parameters never studied before. This study aimed to evaluate bone formation around dental implants in alloxan diabetic rats without treatment, controlled with insulin, and non diabetic rats. Materials and Methods: 72 Wistar rats, male, healthy at clinical examination, weighing between 200 and 300g were divided into three experimental groups of 24 animals each, a normal control group (CG), an untreated diabetic group (DG) and a diabetic group treated with insulin (IG). The animals received dental implants in the right femur and were assessed at three post-operative moments (7, 14 and 21 days), which analyzed clinical (body weight and diuresis) and laboratorial parameters (fasting glucose, hemoglobin glycosylated and serum insulin). In each of the mentioned moments the animals were sacrificed and the femur with the implant was removed, and four specimens of animals used for ultrastructural analysis on scanning electron microscopy, and another 4 to hystopathological examination by light microscopy method HE staining. Induction of diabetes was made by intravenous injection of alloxan 2% in a single dose of 42mg/kg. Were included in the experiment only animals... (Complete abstract click electronic access below) / Orientador: Erika Veruska Paiva Ortolan / Coorientador: Carlos dos Reis Pereira de Araújo / Banca: César Tadeu Spadella / Banca: César Augusto Magalhães Benfatti / Mestre
339

Influência da colocação de enxerto de tecido conjuntivo ao redor de implantes instalados em áreas estéticas : estudo clínico controlado e randomizado /

Lazzari, Thiago Rodrigues. January 2017 (has links)
Orientador: Maria Aparecida Neves Jardini / Coorientador : Sergio Lopes / Banca: Mauro Pedrine Santamaria / Banca: Luciana Machion Shaddox / Resumo: Os implantes dentários têm sido utilizados desde meados da década de 50, e inúmeros estudos garantem a confiabilidade para sua utilização, dessa forma o implante tem se tornado uma prática comum entre os cirurgiões dentistas. À medida que sua utilização vem crescendo, suas complicações também aumentaram, principalmente quando instalados em áreas estéticas, onde há deficiência de tecido conjuntivo perimplantar. O objetivo deste estudo clínico controlado randomizado foi avaliar o aumento do volume de tecido conjuntivo perimplantar em implantes instalados em áreas estéticas com a utilização de enxerto de tecido conjuntivo. Para este estudo, foi utilizada uma amostra de 42 indivíduos com necessidade de implantes em áreas estéticas, onde o grupo teste (n=20) recebeu enxerto de tecido conjuntivo sobre os implantes e o grupo controle (n=22) recebeu apenas o implante dental sem a colocação de enxerto de tecido conjuntivo. Para análise do aumento do tecido perimplantar foram realizadas medidas clínicas no baseline, trans-operatório e pós-operatório de 4 meses. Após 4 meses o grupo teste apresentou diferença significativa no aumento de tecido conjuntivo, uma média 3,35±1,08mm / 3,62±1,08mm na vestibular e sobre o rebordo respectivamente, quando comparado ao grupo controle 2,08±0,62mm/ 2,51±0,53mm na vestibular e sobre o rebordo respectivamente. Houve diferença significativa na diminuição da deiscência óssea vestibular para o grupo teste uma média de 0,4±0,8mm contra 1,0±0,8mm do grupo ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Dental implants have been used since 1950, and as numerous studies ensure reliability for its use, they implant have become a common practice among dentists. However, complications have also risen from its increased application, especially when they are installed in esthetic areas, where there is deficiency of periimplant soft tissue. The purpose of this randomized controlled trial was to evaluate the increase in volume periimplantar soft tissue esthetic areas with the use of connective tissue graft. Individuals in need of implants in esthetic areas were included, and divided in two groups: test group (n = 20) received a tissue graft over the implants and the control group (n = 22) received only dental implant without the connective tissue graft placement. For the analysis of periimplantar tissue augmentation, baseline, trans-operative and postoperative measurements were performed. After 4 months, the test group presented a significant difference in mean connective tissue augmentation, with 3.35 ± 1.08 mm in the vestibular area and 3.62 ± 1.08 mm on the ridge when compared to the control group, with 2.08 ± 0 62 mm in the vestibular area and 2.51 ± 0.53mm on the ridge. There was a significant difference in the reduction of vestibular bone dehiscence for the test group, with a mean of 0.4 ± 0.8 mm versus 1.0 ± 0.8 mm in the control group (p <0.05). There was no significant difference in pain reported by patients and the amount of post-operative analgesics ingested taken. It can be concluded that after 4 months the use of connective tissue graft test group resulted in an increase in connective tissue volume, decreased vestibular bone dehiscence with similar amount of postoperative pain than the control group(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
340

Comportamento mecânico de implantes modificados na região de ápice : análise pelo método de elementos finitos, fotoelasticidade, torque de inserção e frequência de ressonância /

Sciasci, Plínio. January 2017 (has links)
Orientador: Luís Geraldo Vaz / Resumo: A proposta deste estudo foi analisar o comportamento mecânico e a distribuição de forças de diferentes geometrias de ápice em implantes cilíndricos por meio de método de elementos finitos (MEF), fotoelasticidade, torque de inserção e frequência de ressonância. Foram usinados quatro tipos de implantes: sem corte apical (A), com corte apical bi-partido (B), corte apical tri-partido (C), corte apical quadri-partido (D) e um quinto (grupo controle) implante Titamax Ti Ex (Neodent, Curitiba, Paraná, Brasil) (E), todos com dimensões (4,1 X 11,0 mm) de plataforma hexagonal externa. Para o ensaio fotoelástico, blocos de acrílico (30X30X10mm) com um implante foram copiados com Borracha Silicone. Dentro de cada molde de silicone foi vertido resina fotoelástica semi-fexível. Para o ensaio fotoelástico duas situações foram simuladas: aplicação de carga axial de 1 kgf e em outro momento aplicação do torque de 10 N.cm. As fotografias realizadas no polariscópio circular foram transferidas para um computador para leitura dos parâmetros fotoelásticos no software powerpoint (Office 2010). Para o estudo de elementos finitos, o desenho dos implantes foram reproduzidos em CAD (computer Aided design) através do software Autodesk Inventor® (versão 2015, São Paulo, Brasil) e o bloco ósseo tipo IV de dimensões (2X2X2cm) foram posteriormente processados pelo software Rhinoceros v5.0 SR8 (McNeel North America, Seattle, WA, USA). As simulações foram executadas pelo software (Ansys Workbench 10.0, Swanso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to analyze the mechanical behavior and force distribution of five different implant designs using finite element method (FEM), photoelasticity, insertion torque and resonance frequency of different geometric modifications proposed for the apex region Of cylindrical implants. Four types of implants were machined: without apical cut (A), with a two-part apical cut (B), apical tri-split cut (C), apical cut quadri-split (D) and fifth group was composed by Titamax Ti Ex Neodent all with dimensions (4.1 X 11.0 mm). For the photoelastic test, acrylic blocks (30X30X10mm) with implant installed were copied with Blue ASB-10 Silicone Rubber (Polipox). Inside each silicone mold was poured semi-flexible photoelastic resin (Polipox). A titanium UCLA prosthetic intermediate was screwed onto the implant and a dental crown on (Ni-Cr) was fixed on the set. For the photoelastic test two situations were simulated: application of axial load of 1 kgf and torque of 10 N.cm. The photograph and the reading of the photoelastic parameters were performed in a circular polariscope. For the finite element study, the computerAided design (CAD) implants and a Type IV human bone block of dimensions (2X2X2cm) were processed by the software Rhinoceros v5.0 SR8 (McNeel North America, Seattle, WA, USA) At the Renato Archer Information Technology Center (CTI, Campinas, São Paulo - Brazil). The mechanical properties of the implant (titanium grade II) and normal bone type IV were obtai... (Complete abstract click electronic access below) / Doutor

Page generated in 0.1193 seconds