• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 10
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 738
  • 738
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
391

Influência do Diabetes mellitus e da insulinoterapia na osseointegração. Análise por torque reverso em tíbia de coelhos

Margonar, Rogério [UNESP] 27 February 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-02-27Bitstream added on 2014-06-13T18:57:07Z : No. of bitstreams: 1 margonar_r_me_arafo.pdf: 332219 bytes, checksum: 5fcd2066bcc2dc3968cfd7a3894b4ac3 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A indicação da colocação de implantes dentais osseointegrados (IDO) para pacientes com comprometimento sistêmico, como o Diabetes, permanece controversa. O objetivo deste estudo foi avaliar, por meio do torque reverso, a influência do Diabetes Mellitus e, de seu controle com insulina, sobre a osseointegração ao redor de implantes. Foram utilizados 34 coelhos adultos da raça Nova Zelândia, os quais foram divididos nos seguintes grupos: grupo controle (C), grupo Diabetes (D) e grupo Diabetes controlado (DC). A indução do Diabetes foi realizada por administração endovenosa de Aloxana (115 mg/kg). Os coelhos do grupo DC receberam tratamento com injeção subcutânea de insulina (10 U/ dia) e os demais receberam solução salina (0,9%) pela mesma via. Após 1 semana, realizou-se cirurgia de instalação bilateral de implantes nas tíbias de cada animal. Os níveis glicêmicos foram avaliados periodicamente pelo método enzimático da glicose -oxidase. Após 4, 8 e 12 semanas, os animais foram sacrificados e os implantes removidos, sendo o teste do torque de remoção dos mesmos executado com torquímetro manual. No período de 4 semanas, não houve diferenças estatisticamente significativas (p=0.2) entre os grupos quanto ao valor do torque de remoção dos implantes. Porém, o grupo C apresentou valores estatisticamente superiores em relação aos grupos D e DC nos períodos de 8 (p=0.0001 e p=0.0053, respectivamente) e 12 semanas (p=0.0002 e p=0.001, respectivamente). Os grupos D e DC não apresentaram diferenças entre si em nenhum dos períodos avaliados. Assim, pode-se concluir que o Diabettes Mellitus influenciou negativamente a osseointegração de implantes colocados em tíbias de coelhos e a insulinoterapia não alterou este efeito. / The indication for the placement of osseointegrated dental implants in patients with systemic illness, like diabetes, remains controversial. The purpose of this study was to evaluate, through the removal torque test, the influence of Diabetes Mellitus and its control with insulin, on osseointegration around implants. Thirty four New Zealand adult rabbits were separated in 3 groups: control group (C), diabetes group (D) and controlled diabetes group (CD). Aloxana (115mg/kg) was used in diabetes induction. The CD group received treatment with insulin (10 U/ day) and the others received saline solution (0,9%). After 1 week, implants were placed bilaterally in the tibiae of rabbits. After 4, 8 and 12 weeks, the animals were sacrificed and the implants were removed been the removal torque test performed with the aid of a manual torquimeter. At 4 weeks, there were no significant differences (p=0.2) among groups regarding the value for implants removal torque. However, C group showed statistically greater values than D and CD groups at 8 (p=0,0001 and p=0.0053, respectively) and 12 weeks (p=0.0002 and p=0.001, respectively). The groups D and CD didn't showed any significant differences between each other in any period evaluated. Thus, it may be concluded that Diabettes Mellitus can negatively influence the osseointegration around implants in tibiae of rabbits and insulin therapy did not altered this effect.
392

Desenvolvimento da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados. Análise clínica e radiográfica em cães

Martins, Marilia Compagnoni [UNESP] 26 April 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-04-26Bitstream added on 2014-06-13T20:27:59Z : No. of bitstreams: 1 martins_mc_me_arafo.pdf: 1209084 bytes, checksum: 7b11e93ab4898fd54b0df7617be967e1 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Foram avaliados, clínica e radiograficamente, as reações de quatro diferentes superfícies de implante frente ao desenvolvimento e progressão da peri-implantite: Ticp: titânio comercialmente puro; TPS: titânio revestido com plasma spray de titânio; HA: hidroxiapatita; Ost. Superfícies tratadas com ácidos. Para tanto, foram utilizados seis cães, cujos pré-molares inferiores e superiores foram extraídos. Decorridos 90 dias, os implantes foram aleatoriamente colocados, e iniciou-se o controle químico e mecânico do biofilme bacteriano; após o período de osseointegração (90 dias) foram colocados os conectores, e após 45 dias da colocação dos conectores, iniciou-se a indução da peri-implantite por meio de ligaduras de fio de algodão (suspensão do controle do biofilme bacteriano), e os primeiros exames clínicos (profundidade de sondagem, sangramento à sondagem, índices de placa e sangramento, e mobilidade) e radiográficos (perda óssea) foram realizados. Esses parâmetros foram novamente avaliados após 20, 40 e 60 dias, quando da troca das lidaguras. A análise dos resultados não demonstrou diferença significante entre as superfícies, em nenhum dos parâmetros analisados, com exceção da mobilidade (avaliada pelo PeriotestÒ) e perda óssea, que foram menores nos implantes TPS. Concluiu-se que as superfícies apresentam comportamento semelhante durante a indução da peri-implantite, com exceção no parâmetros mobilidade e perda óssea, que apresentaram os implantes TPS com comportamento superior. / The reactions of four different implant surfaces were evaluated in regard to the development and progression of peri-implantitis: titanium commercially pure (Ticp), titanium plasma spray (TPS) hidroxiapatite coated (HA) and acid attached surfaces (Ost). Six dogs had their premolars extracted. After 90 days, the implants were ramdonly placed and the dogs receive soft diet, chemical and mechanical plaque control; after the osseointegration period (90 days), the healing abutments were placed. After the healing period (45 days), the plaque control was suspended, and cotton ligatures were installed when the first clinical (probing depth, bleeding on probing, plaque index, bleeding index, and mobility) and radiographic (bone loss) exams were taken. These parameters were re-exanimate after 20, 40 and 60 days, when the ligatures were changed. The results did not show significant differences between the surfaces in any parameter observed except for the mobility (evaluated with PeriotestÒ), and bone loss. These two parameters had the TPS surface with the lower rates. It was conclude that the surfaces show similar behavior during the induction of peri-implantitis, except for the mobility and bone loss parameters witch the TPS implants had better behavior.
393

Avaliação da formação óssea em implantes dentários de ratos não diabéticos, diabéticos não controlados e controlados com insulina

Souza, Augusto César Rodrigues de [UNESP] 22 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-22Bitstream added on 2014-06-13T20:50:46Z : No. of bitstreams: 1 souza_acr_me_botfm.pdf: 6369001 bytes, checksum: 63be15adf0a9bd8020957c4c744eb8d5 (MD5) / Universidade Estadual Paulista (UNESP) / O diabetes mellitus é considerado hoje, um problema de saúde pública mundial. Na odontologia está associado à doença periodontal, aumentando as chances de perda do elemento dental nos pacientes diabéticos. Implantes dentários são cada vez mais utilizados em pacientes parcialmente ou totalmente edêntulos para reposição dessas perdas. Estudos experimentais, para viabilizar o tratamento dentário de diabéticos através de implantes são cada vez mais freqüentes. Dada a relevância do tema, ainda existem lacunas no estudo da osseointegração de implantes em animais diabéticos. Por isso, visando dar sequência a esses estudos experimentais já existentes, esse estudo foi delineado para avaliação da osseointegração de implantes dentários em animais normais, diabéticos e diabéticos tratados com insulina, utilizando parâmetros adicionais nunca antes avaliados. O presente estudo teve como objetivo avaliar a formação óssea ao redor de implantes dentários em ratos diabéticos aloxânicos controlados com insulina, em relação a ratos não diabéticos e diabéticos não controlados. Foram avaliados 72 ratos da raça Wistar, machos, sadios ao exame clínico, pesando entre 200 e 300g, distribuídos em três grupos experimentais de 24 animais cada, sendo um grupo controle normal (GC), um grupo diabético sem tratamento (GD) e um grupo diabético tratado com insulina (GI). Os animais receberam os implantes dentários no fêmur direito e foram avaliados em três momentos pós-operatórios (7º, 14º e 21ºdias), onde foram analisadas a evolução clínica (peso corporal e diurese), exames laboratoriais (glicemia de jejum, hemoglobina glicosilada e insulina sérica). Em cada um dos momentos mencionados os animais foram sacrificados e retirado o fêmur com o implante, sendo espécimes de 4 animais utilizados para análise ultraestrutural das fibras colágenas, à microscopia... / Diabetes mellitus is nowadays a public health problem worldwide. In dentistry is associated with periodontal disease, increasing the possibilities of tooth loss in diabetic patients. Dental implants are been commonly used in patients partially or completely edentulous to replace these losses. Experimental studies, to enable the dental treatment of diabetics through implants are becoming more frequent. Despite the relevance of the issue , there are still gaps in the study of osseointegration of implants in diabetic animals . Therefore, in order to fulfill some of these questions, this study was designed to evaluate the osseointegration of dental implants in normal, diabetic and diabetic treated with insulin animals, using additional parameters never studied before. This study aimed to evaluate bone formation around dental implants in alloxan diabetic rats without treatment, controlled with insulin, and non diabetic rats. Materials and Methods: 72 Wistar rats, male, healthy at clinical examination, weighing between 200 and 300g were divided into three experimental groups of 24 animals each, a normal control group (CG), an untreated diabetic group (DG) and a diabetic group treated with insulin (IG). The animals received dental implants in the right femur and were assessed at three post-operative moments (7, 14 and 21 days), which analyzed clinical (body weight and diuresis) and laboratorial parameters (fasting glucose, hemoglobin glycosylated and serum insulin). In each of the mentioned moments the animals were sacrificed and the femur with the implant was removed, and four specimens of animals used for ultrastructural analysis on scanning electron microscopy, and another 4 to hystopathological examination by light microscopy method HE staining. Induction of diabetes was made by intravenous injection of alloxan 2% in a single dose of 42mg/kg. Were included in the experiment only animals... (Complete abstract click electronic access below)
394

Influência da técnica cirúrgica guiada para implantes sobre o aquecimento ósseo, a viabilidade celular imediata e a deformação de fresas após osteotomia para implantes

Santos, Pâmela Letícia dos [UNESP] 22 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-22Bitstream added on 2014-06-13T20:50:50Z : No. of bitstreams: 1 santos_pl_me_araca.pdf: 11429192 bytes, checksum: d6972580cfad1fbdb5b39c5833a3da0b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste trabalho foi avaliar o efeito da osteotomia para implantes, seguindo o protocolo de cirurgia guiada comparando-o com a clássica, sobre o aquecimento tecidual, bem como verificar o desgaste das fresas por microscopia eletrônica de varredura e a viabilidade celular imediata. Para isso foram utilizadas tíbias de 20 coelhos, divididos em 2 grupos – GRUPO CONTROLE (GC) e GRUPO GUIADA (GG) - os quais foram divididos em 5 subgrupos (G): G0, GI, G2, G3, G4, que corresponderam às fresas sem uso e as utilizadas 10, 20, 30 e 40 vezes, respectivamente. Cada animal recebeu 10 seqüências de osteotomias, sendo 5 de cada grupo, aleatoriamente em cada tíbia, na velocidade de 1600 r.p.m, e por meio de irrigação externa. A oscilação térmica tecidual durante cada fresagem foi quantificada por meio de termopares. As brocas foram analisadas por microscopia eletrônica de varredura (MEV) e a quantificação da deformação das fresas foi realizada por meio do software ImageLab 2000. As áreas osteotomizadas foram coletadas, processadas para inclusão em parafina, e submetidas ao processamento imunoistoquímico para a expressão das proteínas osteoprotegerina (OPG), Receptor Ativador do Fator Nuclear k (RANKL), osteocalcina (OC) e caspase 3(cas 3). Os dados obtidos por meio da análise térmica foram submetidos ao teste de Mann-Whitney (p=0,05), já os valores de deformação das brocas foram submetidos ao teste t. O aquecimento ósseo no GG foi estatisticamente maior do que no GC. Na análise por meio do MEV, não houve diferença estatística entre os grupos, mas verificou-se que a deformação foi progressiva de acordo com a maior utilização das fresas. Na análise da viabilidade celular, não houve diferença... / The purpose of this study was to evaluate the effect of osteotomy for implants, following the protocol guided surgery comparing it with the classical, tissue heating, check the wear of the drills by scanning electron microscopy, and cell viability. For such purpose, the tibia of 20 rabbits were divided into 2 groups - Control Group (CG) and GUIDED GROUP (GG) - which were divided into five subgroups (G): G0, GI, G2, G3, G4, which corresponded to the cutters without used and used 10, 20, 30 and 40 times respectively. Each animal received 10 sequences osteotomies, 5 in each group randomly in each tibia at a speed of 1600 rpm, and through external irrigation. The tissue thermal oscillation during each milling was measured using thermocouples. The drills were analyzed by scanning electron microscopy (SEM), and quantification of the deformation of the cutters was performed using the software ImageLab2000. Osteotomized areas were collected, processed for paraffin, and subjected to immunohistochemical processing for the protein expression of osteoprotegerin (OPG), Receptor Activator of Nuclear Factor k (RANKL), osteocalcin (OC) and caspase 3 (cas 3). The data obtained by thermal analysis were tested using the Mann-Whitney test (p = 0.05), the strain values of the drills were tested using parametric t-test. Results in the heating bone in the GG was statistically higher than in CG. In the analysis by means of SEM, it was found that deformation was progressive in accordance with the increased use of milling drills. In the analysis of cell viability, no statistical difference when comparing each protein, OPG, RANKL and CASPASE-3, between groups. In the comparison between the OC and GG GC, there was a statistically significant difference. According to the... (Complete abstract click electronic access below)
395

Avaliação da deformação, perda de massa e rugosidade das fresas, após osteotomia para implantes osseointegrados, com diferentes tipos de metais

Sartori, Elisa Mattias [UNESP] 13 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-13Bitstream added on 2014-06-13T19:30:04Z : No. of bitstreams: 1 sartori_em_me_araca.pdf: 1981097 bytes, checksum: 108176df6308fa34d3c4ef0f7ea4c265 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: Avaliar comparativamente, em costela bovina, a deformação, a rugosidade e a perda de massa, de três diferentes tipos de tratamento de superfície de fresas, utilizadas em osteotomias, para instalação de implantes osseointegráveis. Materiais e método: Foram utilizadas 25 costelas bovinas e 3 tipos de fresas helicoidais de 2.0 mm e 3.0 mm para osteotomias para instalação de implantes (Fresa de aço (G1), Fresa com revestimento de filme de Carboneto de Tungstênio em Matriz de Carbono (G2) e Fresa de Zircônia (G3)), que foram subdivididas em 5 subgrupos: 1 – fresas sem uso e 2, 3, 4 e 5 correspondente ao número de perfurações 10, 20, 30 e 40, respectivamente. Todas as fresas foram submetidas a medidas de rugosidade (Ra, Rz e Rmáx), massa (gramas) e análise em microscópio eletrônico de varredura (MEV) antes e após uso. Os dados foram tabulados e submetidos a análise estatística através do Teste de Kruskal-Wallis e, quando encontrada diferença estatisticamente significante, ao Teste de Dunn. Resultados: Houve perda de massa em todos os grupos (G1, G2 e G3), sendo essa redução de forma gradual, conforme o número de perfurações realizadas (1, 2, 3, 4 e 5). Mas esta diferença não foi estatisticamente significante (P<0,05). Ao analisarmos os testes de rugosidade o G3 apresentou aumento de Ra, Rz e Rmáx (P<0,05) em relação ao G2. E um aumento de Ra em relação ao G1. Não houve diferença estatisticamente significante (P<0,05) entre G1 e G2. Na análise por microscopia eletrônica de varredura (MEV) foram observadas áreas de deformação em todas as amostras de 2.0 mm, com perda de substratos, sendo o G3 o que mais apresentou essas características. Conclusão: As fresas de Zircônia de 2.0 mm apresentaram maior perda de substratos e desgaste por abrasão, na região de corte. Apresentaram... / Purpose: Evaluate comparativily, in bovine ribs, the deformation, rugosity and loss of mass, in three different types of bur covering, used in dental implants osteotomy. Materials and methods: Twenty five (25) bovine ribs and three (3) types of helical burs of 2.0 mm and 3.0 mm for dental implant bed preparation had been used (Stell Bur (G1), Tungsten Carbid inCarbon Matriz Bur (G2) and Zirconia Bur (G3)), that they had been subdivided in five sub-groups: 1 – bur without use and 2, 3, 4 and 5 correspondent to the number of perfurations: 10, 20, 30 and 40, respectively. All burs had been measure in rugosity tests (Ra, Rz and Rmax), mass (gram) and scanning electron microscope (SEM) analisys before and after use. The data had been tabulated and submitted to statistical analysis through Kruskal-Wallis Test and, when significant statistical differnces were found, to Dunn Methods Test. Results: Loss of mass where found in all groups (G1, G2 and G3), being this reduction in gradual form as the number of carried through perfurations (1, 2, 3, 4 and 5). But this difference was not statistical significant (P<0,05). When analyzing the rugosity tests the G3 presented increase of Ra, Rz and Rmax (P<0,05) in relation to G2. And a increase of Ra in relation to G1. It did not have significany statistical difference (P<0,05) between G1 and G2. In the scanning electron microscope (SEM) analysis it was observed in all the 2.0 mm samples plastic deformation and drill wear, having been G3 what more it presented these characteristics. Conclusion: The 2.0 mm Zirconia burs had presented major consuming and drill wear in the cutting area. They had presented, also, an increase of rugosity related to G1 and G2. There was no significant statistical differences... (Complete abstract click electronic access below)
396

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four / In vitro analysis of the accuracy of splinting impression techniques using all-on-four system

Pimentel, Gustavo Henrique Diniz [UNESP] 15 October 2014 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-15. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000874738.pdf: 3429941 bytes, checksum: f0746f3294aca82e94682f551d6b7ae5 (MD5) / O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar in vitro a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema All-on-four). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate in vitro the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating All-on-four system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
397

Análise comparativa de técnicas de moldagem para próteses implantossuportadas

Amaral, Ângela Líbia Chagas [UNESP] 20 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-20Bitstream added on 2014-06-13T18:58:44Z : No. of bitstreams: 1 amaral_alc_me_arafo.pdf: 1042757 bytes, checksum: 04d3deeb31a2a6595b470bc935ceb48d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposta: A proposta deste estudo in vitro foi avaliar 3 técnicas de moldagem (Cônico, Hélice e Unido com barra) para próteses implantossuportadas. Materiais e métodos: Um modelo mandibular em latão contendo 4 análogos de implantes e uma estrutura metálica foram confeccionados. Foram utilizados 2 materiais de moldagem: Silicona de polimerização por adição (Express STD, 3M ESPE) e Silicona de polimerização por condensação (Zetaplus/Oranwash, Zermack). Seis grupos foram formados pela combinação entre cada material e técnica de moldagem. Um total de 30 modelos foram fabricados (5 modelos por grupo) e 120 valores de fendas foram analisados (1 valor de fenda para cada análogo de implante). Resultados: Para o material Express, os valores médios de fenda foram: 164,40 μm (Cônico), 97,90 μm (Hélice) e 127,79 μm (Unido). Para o material Zetaplus/Oranwash, os valores médios de fenda foram: 219,37 μm (Cônico), 118,57 μm (Hélice) e 78,50 μm (Unido). Houve uma diferença estatística significante entre o Cônico e a Hélice para o material Express (p<.05). Quando o material avaliado foi o Zetaplus/Oranwash, todos os grupos foram diferentes estatisticamente entre si (p<.05). Conclusões: Os melhores resultados foram alcançados para a Hélice e para Unido quando o material avaliado foi o Express. Para o Zetaplus/Oranwash, a melhor técnica foi o Unido, seguida da Hélice e do Cônico. / Purpose: The purpose of this in vitro study was to evaluate 3 impression techniques (tapered impression copings, squared modified impression copings, and squared impression copings splinted with bur and acrylic resin) for implant-supported prosthesis. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutments analogs and a framework were fabricated. Addition silicone – Express – and condensation silicone – Zetaplus/Oranwash - impression materials were tested. Six groups were formed by combining each material and impression technique. Five casts were made per group for a total of 30 casts and 120 gap values (1 gap value for each implant-abutment analog). Results: With the Express impression material, the mean gap values were 164.40 μm for the tapered group, 97.90 μm for squared modified group and 127.79 μm for squared splinted group. With the Zetaplus/Oranwash impression materials, the mean gap values were 219.37 μm for the tapered group, 118.57 μm for squared modified group and 78.50 μm for squared splinted group. There was significantly difference between tapered impression technique and squared modified impression technique (P<.05), when the material was Express. When the material was the condensation silicone, all groups had significantly difference among themselves (P<.05). Conclusions: The best results were achieved for squared modified impression technique and squared splinted impression techniques, when the impression material was Express. For condensation silicone, the best technique was squared splinted group, followed by squared modified group, and tapered group.
398

Avaliação da eficácia do extrato de óleo insaponificável de abacate e soja na osseointegração em ratos com artrite induzida /

Paula, Luiz Guilherme Freitas de. January 2016 (has links)
Orientador: Rosemary Adriana Chiérici Marcantonio / Resumo: Este estudo avaliou a influência da utilização do extrato de óleo insaponificável de abacate e soja (ASU) na osseointegração de implantes em animais saudáveis e com artrite. Foram utilizados implantes de titânio com 4 mm de comprimento x 2.2 mm de diâmetro, instalados nas tíbias dos ratos. No estudo 1, trinta ratos foram divididos aleatoriamente em três grupos: ASU1: administração de ASU a partir de 7 dias antes da colocação do implante; ASU2: administração de ASU começando no dia da colocação do implante, e CTL: administração de solução salina. Em todos os animais, um implante de titânio foi colocado em cada uma das tíbias. Todos os animais receberam ASU ou solução salina por sonda gástrica diariamente durante 60 dias até o sacrifício. Osseointegração foi avaliada por análise de densidade óssea radiográfica; biomecânica; histologia descritiva; imuno-histoquímica para BMP­2, TGF­β1, e osteocalcina; e avaliação histomorfométrica de contato osso­implante (BIC) e fração de área mineralizada do osso dentro das roscas do implante (BAFO). ASU1 e ASU2 apresentaram maior expressão de BMP­2 e TGF­β1 em comparação com CTL (P<0,05). Na análise histomorfométrica, os grupos ASU1 e ASU2 apresentaram valores significativamente mais elevados BIC somente na região de osso cortical, quando comparado com o CTL (P <0,05). No estudo 2, 120 animais foram divididos randomicamente em quatro grupos: CTR- Animais saudáveis que ingeriram soro; ASU- Animais saudáveis que ingeriram ASU; ART- Animais com ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the influence of the administration of avocado/soybean unsaponifiables (ASU) on implant osseointegration in healthy and arthritis animals. Titanium implants were used with 4 mm length x 2.2 mm diameter, installed in the tibiae of rats. In study 1, thirty rats were randomly divided into three groups: ASU1: ASU administration from 7 days prior to implant placement; ASU2: ASU administration beginning on the day of implant placement, and CTL: saline solution administration. In all animals a titanium implant was placed in each of the tibia. All animals received ASU or saline by gavage every day for 60 days until the sacrifice. Osseointegration was evaluated by analysis of radiographic and biomechanical bone density; descriptive histology, immunohistochemistry for BMP2, TGFβ1, and osteocalcin, and histomorphometric evaluation ossoimplante contact (BIC) and mineralized area fraction of the bone into the threads of the implant (BBT). ASU1 ASU2 and showed increased expression of TGF-β1 and BMP-2 compared to CTL (P <0.05). The histomorphometric analysis, ASU1 and ASU2 groups showed significantly higher values BIC only in the cortical bone region, as compared to the CTL (P <0.05). In study 2, 120 animals were randomly divided into four groups: CTR- Healthy animals who consumed saline solution; ASU- Healthy animals that consumed ASU; ART- Animals with arthritis who consumed saline solution; ART/ASU- Animals with arthritis who consumed ASU. The solutions were administ... (Complete abstract click electronic access below) / Doutor
399

Análise das tensões em próteses implantossuportadas esplintadas, variando o tipo de conexão protética e a inclinação do implante : estudo pelo método dos elementos finitos tridimensionais não linear /

Almeida, Daniel Augusto de Faria. January 2015 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Fellippo Ramos Verri / Banca: Humberto Gennari Filho / Banca: Paulo Renato Junqueira Zuim / Banca: Joel Ferreira Santiago Júnior / Banca: Regina Tamaki / Resumo: O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, este estudo objetivou avaliar a influência da esplintagem e da inclinação de implantes (0º, 17º e 30º) em reabilitações de maxila posterior, na distribuição de tensões pelo método dos elementos finitos tridimensionais não linear. Para isso, foram confeccionados 12 modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Os modelos foram compostos por 3 implantes de hexágono externo (4,1 mm) ou cone morse (4,0 mm) nas regiões: 14 - 10 mm; 15 - 8,5 mm; 16 - 8,5 mm suportando próteses de 3 elementos unitárias ou esplintadas. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 400N axialmente e 200N obliquamente, divididas em cada cúspide das superfícies oclusais. Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho. Os resultados foram importados novamente ao FEMAP 10.2 para visualização e pós-processamento dos mapas de tensão de von Mises e tensão máxima principal. Os resultados... / Abstract: The performance of an osseointegrated dental implant plays important rule for functional longevity of the rehabilitation. Sometimes, anatomical limitations imply in the positioning of tilted implants that is not considered ideal for prosthetic rehabilitation, generating higher stress concentration around it and leading to cortical bone resorption. To solve these situations, the professional must plan carefully the restoration and to study the connection type of the implant to better adaption for these situations. In this way, this study aimed to evaluate the influence of splinting prostheses and implant inclination (0º, 17º and 30º) in implant-supported prostheses in the posterior region of the maxilla on stress distribution by non-linear 3D finite element analysis. For this, twelve 3D models was confectioned using modeling software SolidWorks 2010 and Rhinoceros 4.0 and software InVesalius. The models constituted of 3 dental implants of external hexagon or morse taper (4,0 mm) at the regions: 14 - 10mm; 15 - 8,5 mm; 16 - 8,5 mm, supporting three-unit prostheses in single and splinting configurations. After modeling, the models were imported to pre- and post-processing software of finite elements FEMAP 10.2 for finite element mesh generation and configuration of restrictions and loading conditions. Axial load of 400N and oblique of 200N were applied divided on each cusp tip of occlusal surface. Next step, it was the analysis configuration on FEMAP 10.2 that was exported to NeiNastran 9.2 to math processing. After, the files of results were imported to FEMAP 10.2 to results visualization and post-processing analysis by plotting von Mises and maximum principal stress maps. The results of bone tissue showed higher stress concentration to inclined implants of external hexagon supporting single crowns under oblique loading. The models with splinted Morse taper... / Doutor
400

Influência do tipo de fundição e uso de retificação na interface pilar/cilindro protético na adaptação marginal e tensão peri-implantar sobre conexão protética tipo Micro-Unit/

Gonçalves, Marianna Cavalheiro. January 2009 (has links)
Orientador: Lafayette Nogueira Júnior / Banca: Eduardo Shigueyuki Uemura / Banca: Alfredo Mikail Mesquita / Resumo: O objetivo neste estudo foi avaliar, in vitro, a adaptação marginal por meio da microscopia óptica, de cilindros pré-fabricados de Co-Cr comparados com cilindros calcináveis fundidos em Ni-Cr pelo método convencional e pela fundição por indução, com e sem o uso de retificadores e analisar por meio da extensometria a tensão ao redor do implante gerada com o uso destes componentes parafusados sobre os pilares tipo Micro-Unit. Foram utilizados 36 cilindros tipo Micro-Unit subdivididos em 3 grupos: G1 (controle) - 12 cilindros pré-fabricados de Co-Cr; G2 - 12 cilindros calcináveis fundidos pelo método convencional em liga de níquel-cromo (Ni-Cr); G3 - 12 cilindros calcináveis fundidos pelo método de indução em liga de Ni-Cr. Para todos grupos foram realizadas as leituras no microscópio óptico com um aumento de 200 vezes e realizada a mensuração da tensão pela extensometria. Na análise microscópica foram realizadas quatro leituras para cada face do octógono no qual o implante estava instalado. A extensometria foi realizada durante o aperto do parafuso, com torquímetro eletrônico, do cilindro em questão após o implante estar devidamente posicionado sobre o aparato que garantia que o torque era gerado sem nenhuma influencia do operador. Posteriormente, os cilindros dos grupos 2 e 3 foram retificados formando dois sub-grupos: G2b e G3b, os quais foram novamente analisados em microscópio óptico e na extensometria. Os valores de média e desvio padrão encontrados na desadaptação marginal nos grupos foram: ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The main point of this study was to evaluate, in vitro, the marginal misfit using the optical microscopy Co-Cr cylinders prefabricated compared with abutment cylinders cast in Ni-Cr conventional casting and by induction, with and without use of rectifiers and analyzed with strain gages around the implant generated with the use of these components bolted on the Micro-Unit abutments. 36 micro-unit cylinders were divided into 3 groups: G1 (control) - 12-pre-fabricated Co-Cr cylinders, G2 - 12 cylinders copings cast with conventional nickel-chromium (Ni-Cr)alloy, G3 - 12 cylinders copings cast method of induction in the Ni-Cr. For all groups were performed measurements at optical microscope with an increase of 200 times (200x) and performed the strain gages measurement. In the microscopic analysis were performed four readings for each side of the octagon in which the implant was installed. The gage was carried out during tightening of the screw with an electronic torque wrench drum in question after the implant to be properly positioned on the apparatus that guarantees that the torque was generated without any influence of the operator. Thereafter, the cylinders in groups 2 and 3 were rectified to form two sub-groups: G3B and G2b, which were further, analyzed using an optical microscope and the strain gages. The mean value and standard deviation found in the marginal discrepancy in the groups were: ... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0713 seconds