• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 82
  • 76
  • 44
  • 40
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 297
  • 128
  • 120
  • 68
  • 66
  • 61
  • 59
  • 58
  • 55
  • 50
  • 46
  • 45
  • 45
  • 42
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Análise da influência de diferentes estratégias de arrefecimento no desempenho e durabilidade de inversores de sistemas fotovoltaicos conectados à rede

Perin, Aryston Luiz January 2016 (has links)
Inversores de sistemas fotovoltaicos são equipamentos de eletrônica de potência que fornecem energia elétrica em corrente alternada (CA) a partir de uma fonte de energia elétrica em corrente contínua (CC), no caso, os módulos fotovoltaicos. Estes inversores quando em operação aumentam sua temperatura. Este aumento de temperatura é indesejável, porém é inerente ao seu funcionamento. Equipamentos eletrônicos possuem um limite seguro de temperatura de operação, acima do qual podem ocorrer instabilidades de operação, redução da vida útil ou até mesmo falha drástica. O conhecimento da eficiência de conversão elétrica e das perdas responsáveis pelo aquecimento é importante para o adequado dimensionamento de inversores quando aplicados em sistemas fotovoltaicos conectados à rede, assim como para o desenvolvimento do inversor como produto. Para proteção, para aumento da vida útil, para maior confiabilidade, para maior estabilidade e para maior segurança de operação de componentes, inversores possuem rotinas em seus algoritmos de controle com estratégias automatizadas dedicadas ao gerenciamento térmico. Estas rotinas de proteção e gerenciamento térmico, sempre quando acionadas, tendem a reduzir a capacidade de conversão de potência do inversor, seja pelo acionamento de um ventilador auxiliar, seja pelo deslocamento do ponto de operação em máxima potência. Fabricantes de inversores tratam deste assunto pelo termo “temperature derating” (em inglês) Esta tese apresenta um estudo relacionado a influência da temperatura sobre o desempenho de inversores fotovoltaicos conectados à rede. Avalia tipos de estratégias de gerenciamento térmico e proteção de uso corrente em inversores comerciais. Apresenta resultados de ensaios experimentais para determinação de parâmetros térmicos característicos dos inversores. Descreve um modelo preditivo da temperatura de operação em regime transiente. A partir da determinação experimental de parâmetros térmicos, o modelo preditivo de temperatura de operação foi implementado no software de simulação dinâmica para dimensionamento e avaliação de sistemas fotovoltaicos FVCONECT, desenvolvido no LABSOL/UFRGS, estando o mesmo apto para simular a operação e estimar perdas anuais de desempenho energético decorrentes das rotinas de gerenciamento térmico, dos seus efeitos e das limitações impostas durante a operação de inversores fotovoltaicos conectados à rede. Um dos resultados da simulação é a evolução da temperatura do inversor, permitindo avaliar a frequência e amplitude dos ciclos térmicos ao qual o inversor é submetido e, consequentemente, determinar uma estimativa para durabilidade do inversor. / Photovoltaic inverters are electronic power devices that provide electrical energy in alternating current (AC) from a source of electrical energy in direct current (DC) - a photovoltaic generator, in this case. Inverters increase their temperature when in operation. This rise in temperature is not desirable, but inherent to its operation. Any electronic equipment has a safe operating temperature limit. When this limit is surpassed, operating instability, life reduction or even drastic failure may occur. The knowledge of the electrical conversion efficiency and the losses responsible for the heating is important for the proper sizing of grid-tie inverters in photovoltaic systems, as well as for the development of the inverter as a product. In order to increase the useful life of the device and its components, for greater reliability, safety, stability and security of operation, inverters have routines in their algorithms of control with automated strategies dedicated to the thermal management. These protection and thermal management routines, whenever activated, tend to reduce the power conversion capacity of the inverter, either by the activation of an auxiliary fan or by the displacement of the operating point at maximum power. Inverter manufacturers address this issue by the term "temperature derating". This thesis presents a methodology to evaluate the influence of the performance of different strategies to avoid excessive temperature of the inverter components on its performance and durability It is also made an evaluation of different thermal management strategies and protection used in commercial inverters. Results of experimental tests for determination of thermal parameters characteristic of the inverters are presented. A predictive model of transient operating inverter temperature is also described. From the experimental determination of thermal parameters, the predictive model of operating temperature was implemented to the FVCONECT, a dynamic simulation software for sizing and evaluation of photovoltaic systems developed in LABSOL / UFRGS. With this modification, the software was able to simulate the operation and estimate losses of energy due to the thermal management routines, their effects and the limitations imposed during the operation of grid-tie inverters. One of the results of the simulation is the evolution of the inverter temperature, allowing to evaluate the frequency and amplitude of thermal cycles to which the inverter is subjected and, as a consequence, an estimate of durability of the inverter.
182

Modelagem de cargas não lineares e rede de energia elétrica para simulação de sistemas fotovoltaicos conectados à rede

Pufal, Ricardo Augusto January 2012 (has links)
Os inversores utilizados no sistema fotovoltaico conectados à rede (SFCR) devem apresentar uma forma de onda senoidal nos seus terminais de saída. Monitoram regularmente a qualidade de energia da rede elétrica aos quais estão conectados, de maneira a só gerarem energia se a rede estiver com tensão. Dependendo do inversor, da potência que ele está desenvolvendo em relação à sua potência nominal, da rede ao qual está conectado e das características da carga que ele alimentará, podem ser apresentadas distorções na rede de energia em relação à forma de onda senoidal pura, tanto a nível de tensão como a nível de corrente elétrica. Não é incomum os dispositivos que são conectados a redes apresentarem-se como geradores de harmônicos, principalmente os eletrônicos. Estas distorções, conhecidas na literatura como distorções harmônicas, afetam o desempenho dos inversores quando ligados a redes elétricas. Nestas redes, como pode haver distorções significativas. Os parâmetros elétricos que os inversores se baseiam para obter as características da rede a qual estão conectados,devido a estas distorções, podem fazer com que os mesmos se desconectem. O inversor também se desconectará automaticamente da rede ao perceber a ocorrência de variação acentuada da rede ou a falta dela; a esse sistema, dá-se a denominação antiilhamento. Portanto, é de bastante importância que se consiga reproduzir teoricamente o comportamento das cargas e das redes elétricas, nas quais os inversores serão conectados para que seja possível estudá-los quando interligados às diferentes cargas. Entretanto, devido ao inversor ser também um equipamento eletrônico baseado em fonte chaveada para “remontar” a onda senoidal, o mesmo também acaba introduzindo uma deformação tanto na tensão como na corrente da rede elétrica ao qual está conectado, e esta deformação é também significativa em SFCR de grande porte (instalação de geração fotovoltaica com grande número de inversores). Assim, este trabalho visa implementar a modelagem de cargas não lineares (degradadoras da qualidade de energia) para serem aplicadas em simulações de inversores de SFCR, com aplicação especial no parâmetro “cargas” do programa para computadores FVCONECT desenvolvido pelo Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul. / It is known that the inverters used in photovoltaic systems connected to mains power (SFCR), when connected to the power grid, should provide a sinusoidal waveform at its output terminals. The photovoltaic systems inverters regularly monitor the power grid quality they are connected to, so they generate power only if the grid of the Concessionaire or external power grid presents voltage. Depending on the inverter, on the power that it develops over the same rated power, on the power grid it is connected to and on the characteristics of the load that it also feeds, it is possible to occur certain distortions on the power grid compared to pure sine waveform, in terms of voltage or even in terms of electric current. The devices connected to grid commonly present themselves as harmonic generators. The loads cause large distortions in the power grid causing disorders occur both voltage and current in a distribution line or power circuit. These distortions, commented in the literature as harmonic distortions, greatly affect the inverters performance when connected to power grids. On these grids, as it is possible to identify significant distortions, the parameters for pairing the power grid, in which the inverters are based, can turn them into disconnection. The inverter automatically disconnects from the grid if for some reason the grid stops powering the power grid - such system is called anti-islanding. Therefore, it is important to theoretically reproduce the behavior of power grids which the inverters are connected to, in order to study them. However, due to the fact that the inverter is also a switched source-based electronic equipment to "reassemble" the sine wave, it provides a deformation not only on the voltage but also on the power grid current which it is connected to, being this deformation also significant in large SFCR (photovoltaic generation facility with large numbers of inverters). In this sense, the present work aims to implement the modeling of nonlinear loads (which can degrade the power quality) in SFCR inverters simulations, based on the special application of loads parameters from the FVCONECT software, developed by the Solar Energy Laboratory, Federal University of Rio Grande do Sul.
183

A New Conception of Multilevel Inverter for UPS Application / Uma nova concepÃÃo de inversor multinÃvel para aplicaÃÃo em UPS

Lincoln Moura de Oliveira 23 November 2009 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / This work deals with the theoretical analysis, design methodology and laboratory implementation of a 3kVA on-line mode Uninterruptible Power Supply (UPS) composed by a multilevel inverter based on a transformer with multiple secondaries and an active power factor correction input stage composed by a diode rectifier in series with a boost converter.The main motivation for this study is to assess the benefits of multilevel inverters in low power (<10kVA) applications. A 3kVA Uninterruptible Power Supply (UPS) with output and input voltage of 220V and 60Hz, has been implemented. Simulation and experimental results for a single phase prototype are conducted to validate the proposed idea. The utilization of low frequency operation inverters promotes low EMI, lower switches stresses, very low commutation losses and consequently higher efficiency. The multilevel converter here used isolates the load from the grid due to the multi-windings transformer intrinsic to the topology. The on-line mode of the UPS (no battery mode) has been implemented. Simulation and experimental results for a single-phase prototype are presented to validate the proposed converter. The UPS presented an efficiency of 90% / Este trabalho apresenta a anÃlise teÃrica, metodologia de projeto e implementaÃÃo do modo rede de um sistema ininterrupto de energia (UPS) na configuraÃÃo on-line, utilizando um inversor multinÃvel e um prÃ-regulador com correÃÃo de fator de potÃncia. O inversor baseia-se num transformador que opera em baixa freqÃÃncia com mÃltiplos secundÃrios isolados, em que a tensÃo multinÃvel na saÃda à formada atravÃs da combinaÃÃo dos enrolamentos secundÃrios do transformador por chaves de potÃncia estÃticas operando em baixa freqÃÃncia. O prÃ-regulador à composto por uma ponte completa de diodos em sÃrie com um conversor boost. A motivaÃÃo para este estudo consiste em avaliar os benefÃcios da utilizaÃÃo de inversores multinÃveis em baixas potÃncias (<10kVA) em UPS, com Ãnfase nos rendimentos das topologias. A utilizaÃÃo do inversor multinÃvel operando em baixa freqÃÃncia garante menores Ãndices de EMI, menores esforÃos de tensÃo e corrente nos semicondutores da estrutura, desprezÃveis perdas por comutaÃÃo e consequentemente maior rendimento. A estrutura utilizada possui ainda a caracterÃstica de garantir isolamento galvÃnico da rede elÃtrica com a carga atravÃs da utilizaÃÃo do transformador intrÃnseco desta topologia. O prÃregulador possui uma topologia que garante facilidade de implementaÃÃo e alto rendimento. O modo rede de um sistema ininterrupto de energia de 3kVA com tensÃo de entrada e saÃda de 220V e 60Hz, foi implementado. As simulaÃÃes e os resultados experimentais para um protÃtipo monofÃsico sÃo apresentados para a validaÃÃo da estrutura. O rendimento mÃximo obtido para o protÃtipo foi de 90%.
184

Modelagem de cargas não lineares e rede de energia elétrica para simulação de sistemas fotovoltaicos conectados à rede

Pufal, Ricardo Augusto January 2012 (has links)
Os inversores utilizados no sistema fotovoltaico conectados à rede (SFCR) devem apresentar uma forma de onda senoidal nos seus terminais de saída. Monitoram regularmente a qualidade de energia da rede elétrica aos quais estão conectados, de maneira a só gerarem energia se a rede estiver com tensão. Dependendo do inversor, da potência que ele está desenvolvendo em relação à sua potência nominal, da rede ao qual está conectado e das características da carga que ele alimentará, podem ser apresentadas distorções na rede de energia em relação à forma de onda senoidal pura, tanto a nível de tensão como a nível de corrente elétrica. Não é incomum os dispositivos que são conectados a redes apresentarem-se como geradores de harmônicos, principalmente os eletrônicos. Estas distorções, conhecidas na literatura como distorções harmônicas, afetam o desempenho dos inversores quando ligados a redes elétricas. Nestas redes, como pode haver distorções significativas. Os parâmetros elétricos que os inversores se baseiam para obter as características da rede a qual estão conectados,devido a estas distorções, podem fazer com que os mesmos se desconectem. O inversor também se desconectará automaticamente da rede ao perceber a ocorrência de variação acentuada da rede ou a falta dela; a esse sistema, dá-se a denominação antiilhamento. Portanto, é de bastante importância que se consiga reproduzir teoricamente o comportamento das cargas e das redes elétricas, nas quais os inversores serão conectados para que seja possível estudá-los quando interligados às diferentes cargas. Entretanto, devido ao inversor ser também um equipamento eletrônico baseado em fonte chaveada para “remontar” a onda senoidal, o mesmo também acaba introduzindo uma deformação tanto na tensão como na corrente da rede elétrica ao qual está conectado, e esta deformação é também significativa em SFCR de grande porte (instalação de geração fotovoltaica com grande número de inversores). Assim, este trabalho visa implementar a modelagem de cargas não lineares (degradadoras da qualidade de energia) para serem aplicadas em simulações de inversores de SFCR, com aplicação especial no parâmetro “cargas” do programa para computadores FVCONECT desenvolvido pelo Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul. / It is known that the inverters used in photovoltaic systems connected to mains power (SFCR), when connected to the power grid, should provide a sinusoidal waveform at its output terminals. The photovoltaic systems inverters regularly monitor the power grid quality they are connected to, so they generate power only if the grid of the Concessionaire or external power grid presents voltage. Depending on the inverter, on the power that it develops over the same rated power, on the power grid it is connected to and on the characteristics of the load that it also feeds, it is possible to occur certain distortions on the power grid compared to pure sine waveform, in terms of voltage or even in terms of electric current. The devices connected to grid commonly present themselves as harmonic generators. The loads cause large distortions in the power grid causing disorders occur both voltage and current in a distribution line or power circuit. These distortions, commented in the literature as harmonic distortions, greatly affect the inverters performance when connected to power grids. On these grids, as it is possible to identify significant distortions, the parameters for pairing the power grid, in which the inverters are based, can turn them into disconnection. The inverter automatically disconnects from the grid if for some reason the grid stops powering the power grid - such system is called anti-islanding. Therefore, it is important to theoretically reproduce the behavior of power grids which the inverters are connected to, in order to study them. However, due to the fact that the inverter is also a switched source-based electronic equipment to "reassemble" the sine wave, it provides a deformation not only on the voltage but also on the power grid current which it is connected to, being this deformation also significant in large SFCR (photovoltaic generation facility with large numbers of inverters). In this sense, the present work aims to implement the modeling of nonlinear loads (which can degrade the power quality) in SFCR inverters simulations, based on the special application of loads parameters from the FVCONECT software, developed by the Solar Energy Laboratory, Federal University of Rio Grande do Sul.
185

âUma Proposta de Projeto Para Inversor MultinÃvel em Cascata AssimÃtrico com 63 NÃveis na TensÃo de SaÃda e OperaÃÃo em Baixa FrequÃnciaâ / "Design Proposition For a 63 Levels Output Voltage Asymmetric Multilevel Cascaded Inverter at low Frequency Operation"

Samuel Jo de Mesquita 11 February 2011 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / "Este trabalho apresenta um estudo dos inversores multinÃveis em cascata usando cÃlulas H-bridge na configuraÃÃo assimÃtrica usando transformador de mÃltiplos secundÃrios. Ele demonstra equaÃÃes para o cÃlculo da freqÃÃncia das cÃlulas para o inversor operando com as configuraÃÃes binÃria e ternÃria, bem como o projeto completo do transformador toroidal com nÃcleo laminado. Este trabalho define a melhor freqÃÃncia de operaÃÃo do transformador que possibilita reduÃÃo no tamanho se comparado a operaÃÃo em 60 Hz. Ele tambÃm aborda uma metodologia para o cÃlculo das perdas nas cÃlulas do inversor as quais sÃo Ãteis para o cÃlculo tÃrmico do inversor." / This dissertation proposes a design of a cascaded multilevel inverter using H-bridge cells in asymmetric configuration and a multiple secondary transformer. Equations for determining the frequency operation of each cell with binary and ternary configurations, as well as the complete design of toroidal transformer with laminated core. This work proposes also the optimal operating frequency of the transformer that enables reduction in core size, when compared to 60 Hz operation. It is also discussed a methodology for calculate the losses in the cells of the inverter, which are useful to determine the thermal behavior of the inverter.
186

Design and implementation of a multilevel active power filter for more electric aircraft variable frequency systems = Aplicação de filtros ativos multiníveis em sistemas elétricos de aeronaves em regime de frequência variável / Aplicação de filtros ativos multiníveis em sistemas elétricos de aeronaves em regime de frequência variável

Guerreiro, Joel Filipe, 1988- 25 August 2018 (has links)
Orientador: José Antenor Pomilio / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T18:11:11Z (GMT). No. of bitstreams: 1 Guerreiro_JoelFilipe_M.pdf: 10178060 bytes, checksum: 342fb378bb2d1fd88084a0360e541d24 (MD5) Previous issue date: 2014 / Resumo: Filtros Ativos de Potência Aeronáuticos (FAPA) são geralmente utilizados para melhoria da Qualidade da Energia em Sistemas Elétricos de Potência Aeronáuticos (SEPA). Os FAPA compensam os harmônicos de corrente, aumentam o fator de potência e minimizam os efeitos de cargas desbalanceadas. Este trabalho apresenta o desenvolvimento, simulação e implementação de um FAPA pra um SEPA avançado de velocidade e frequência variável. O SEPA é muito diferente dos sistemas elétricos residenciais e industriais, nesses sistemas a frequência pode variar de 360 Hz a 800 Hz, além do mais a carga se reconfigura repetidamente. Deste modo, uma estratégia avançada de filtragem ativa é necessária para SEPAs, O FAPA proposto neste trabalho é composto por um inversor multinível do tipo cascata assimétrica, o algoritmo de controle é implementado utilizando a teoria da potência conservativa e a sincronia do FAPA com o SIPA é realizada por meio de um algoritmo PLL com filtro de Kalman. Um protótipo trifásico é implementado para validar ambos o FAPA e as simulações / Abstract: Aircraft Active Power Filters (AAPFs) are most commonly used to improve energy quality in Aircraft Electrical Power Systems (AEPS by means of mitigating current harmonics, improving the source power factor and minimizing the effects of unbalanced loads. This work presents the design, simulation and implementation of a Multilevel AAPF for a Variable Speed Variable Frequency (VSVF) advanced aircraft electric power system. The AEPS is very different than the residential and industrial power systems, in these systems, the frequency may vary between 360 Hz and 800 Hz, and the load dynamics is often modified. For aircraft purposes an enhanced filtering technique is required. The proposed AAPF topology is composed by an Asymmetrical Multilevel Inverter (AMI), controlled by the Conservative Power Theory (CPT) and synchronized by a Kalman Filter Phase-Locked Loop (KF-PLL). A three phase AAPF prototype was implemented in order to investigate the proper system operation and accurateness to the simulations / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
187

Elkvalitetsundersökning av solcellsanläggningarna på Sundsvalls sjukhus

Hallin, Mattias January 2017 (has links)
Landstinget Västernorrland har i dagsläget installerat cirka 2600 kvadratmeter solpaneler på sina sjukhus i länet. Planer finns att utöka detta ytterligare. Eftersom solenergin står för en växande andel av elförsörjningen på dessa sjukhus, så väcks frågan om detta kommer ha någon negativ påverkan på dessa sjukhus elkvalitet.   Syftet med arbetet är undersöka om elkvaliteten i inmatningspunkterna för solcellsanläggningarna ligger inom gränsvärdena specificerade enligt EIFS 2013:1 för allmän distribution, samt om någon negativ på-verkan kan påvisas från solcellernas elproduktion. Resultatet visade att samtliga punkter i föreskriften EIFS 2013:1 för elkvalitet uppfylldes.   Det gick inte att påvisa att produktionen från solcellerna hade någon direkt negativ påverkan på sjukhusets elkvalitet i mätpunkterna som undersöktes. Denna slutsats kunde stödjas av att de psykiatriska avdelningar visade god elkvalitet, trots att den installerade effekten solceller är ungefär dubbelt så stor där som på det centrala sjukhuset.   Montagevinkeln för solpanelerna undersöktes också, och enligt en simulering som utfördes i PVGIS, så visade det sig att den optimala vinkeln för en enskild solpanel på den aktuella breddgraden är 44 grader. Det behövs dock ytterligare undersökningar för att konstatera om denna vinkel är fördelaktig för samtliga anläggningar på sjukhus-området. Rapporten visar också att de 15:e och 8:e relativa övertonerna har mät-värden som ligger relativt nära gällande gränsvärden. För att upprätt-hålla elkvaliteten på sjukhuset under alla förhållanden, så bör en under-sökning genomföras för att lokalisera de största faktorerna till störningskällorna. / The County Council of Västernorrland has as of today, installed around 2600 square meters of solar panels on their hospitals. There are already plans in place to expand this even further in the future. With ever in-creasing share of their total energy usage being supplied from solar power, the question arises if this will have any negative impact on the electrical power quality at these hospitals.   The purpose of this study is to determine if the electrical power quality is currently within the limits defined by the Swedish regulation EIFS 2013:1, and if the production of electrical power from these smaller photovoltaic plants have any negative effect on the power quality at the measured grid feed-ins. The results showed that the power quality on all measured points passed the requirements for the regulation EIFS 2013:1.   Also, no clear evidence of any negative side effects on the power quality, caused by electrical power production from the solar panels could be determined. This was supported by the measured power quality being better at the psychiatric departments, despite the installed nameplate capacity being about twice as high as on the main hospital building.   The mounting angle of around 15 degrees was found not to be optimal for a single solar panel at the latitude where the installations are located. A simulation ran found the optimal angle to be 44 degrees. Despite this, more investigations are needed to determine if a higher angle is advantageous to all the installations on the investigated hospital area. Lastly, the report showed some reason to be concerned about the 15th and 8th relative harmonics, as they both had measured values being close to the regulation limits. In order to improve power quality in the future, and avoid exceeding regulation limits, it is therefore recommended that an investigation is performed to determine the largest sources of 15th and 8th relative harmonics.
188

Study On DC-Link Capacitor Current In A Three-Level Neutral-Point Clamped Inverter

Gopalakrishnan, K S 07 1900 (has links) (PDF)
Three-level diode-clamped inverter is being widely used these days. Extensive research has been carried out on pulse width modulation (PWM) strategies for a three-level inverter. The most widely used PWM strategies are sine-triangle pulse width modulation (SPWM) and centered space vector pulse width modulation (CSVPWM). The influence of these PWM strategies on the DC-link capacitor current and voltage ripple is studied in this thesis. The sizing of the DC capacitor depends on value of the maximum RMS current flowing through it. In this work, an analytical expression for capacitor RMS current is derived as a function of operating conditions like modulation index, power factor angle of the load and peak load current. The worst case current stress on the capacitor is evaluated using the analytical expression. The capacitor RMS current is found to be the same in SPWM and CSVPWM schemes. The analytical expression is validated through simulations and experiments on a 3kVA MOSFET based three-level inverter. Harmonic analysis of the capacitor current is helpful in better evaluation of capacitor power loss. Therefore, harmonic analysis of the capacitor current is carried out, using the techniques of geometric wall model and double Fourier integral for SPWM and CSVPWM schemes. The theoretical predictions are validated through experiments. The capacitor RMS current is divided into low-frequency RMS current (where low frequency component is defined as a component whose frequency is less than half the switching frequency) and high-frequency RMS current. The capacitor voltage ripple is estimated analytically for SPWM and CSVPWM schemes, using the low-frequency and high-frequency capacitor RMS current. The voltage ripples due to SPWM and CSVPWM schemes are compared. It is found that the voltage ripple with SPWM is higher than that with CSVPWM. A simplified method to estimate the capacitor power loss, without the requirement of FFT analysis of capacitor current, is proposed. The results from this simplified method agree reasonably well with the results from the detailed method. A space vector based modulation scheme is proposed, which reduces the capacitor RMS current at high power factor angles. However, the proposed method leads to higher total harmonic distortion (THD) than CSVPWM. Simulation and experimental results, comparing CSVPWM and the proposed PWM, are presented.
189

Spolupráce mezi statickým měničem a sítí v ostrovním provozu / Cooperation between the inverter and grids in island operation

Urant, Tomáš January 2018 (has links)
This thesis deals with the creation of models of non-volatile sources connected to the power system using power converters and their connection by filter or a transformer. Furthermore, the thesis will deal with the study of the problem of connecting a large number of these sources. Another area of interest is to determine the conditions under which these sources can be used to restore network voltage after a previous outage. In the PSCAD program we will create inverter models (6 pulse, 12 pulse and one phase). In the next step, a network model will be created, where the individual sources will be connected and, in the end, we will simulate the situations. The output of the thesis is to determine the behavior of the largest number of static sources in the system and thus to contribute to the knowledge about the possibilities of safe and stable operation of non-volatile energy sources in the power system.
190

Jämförelse av datakomprimeringsalgoritmer för sensordata i motorstyrenheter / Comparison of data compression algorithms for sensordata in engine control units

Möller, Malin, Persson, Dominique January 2023 (has links)
Begränsad processor- och minneskapacitet är en stor utmaning för loggning avsensorsignaler i motorstyrenheter. För att kunna lagra större mängder data i dessakan komprimering användas. För att kunna implementera komprimering imotorstyrenheter krävs det att algoritmerna klarar de begränsningar som finnsgällande processorkapaciteten och ändå kan producera en godtagbarkomprimeringsgrad.Denna avhandling jämför komprimeringsalgoritmer och undersöker vilken ellervilka algoritmer som är bäst lämpade för detta ändamål. Detta i syfte att förbättraloggning och därmed effektivisera felsökning. Detta gjordes genom att utveckla ettsystem som kör olika komprimeringsalgoritmer på samplad sensordata frånmotorstyrenheter och beräknar komprimeringstid och komprimeringsgrad.Resultaten visade att delta-på-delta-komprimering presterade bättre än xorkomprimering för dessa data. Delta-på-delta presterade betydligt bättre gällandekomprimeringsgrad medan skillnaderna i komprimeringstid mellan algoritmernavar marginella. Delta-på-delta-komprimering bedöms ha god potential förimplementering i loggningssystem för motorstyrenheter. Algoritmen bedöms somväl lämpad för loggning av mindre tidsserier vid viktiga händelser, för merkontinuerlig loggning föreslås fortsatta studier för att undersöka hurkomprimeringsgraden kan förbättras ytterligare. / Limited processor and memory capacity is a major challenge for logging sensorsignals in engine control units. In order to be able to store larger amounts of data,compression can be used. To successfully implement compression algorithms inmotor control units, it is essential that the algorithms can effectively handle thelimitations associated with processor capacity while achieving an acceptable level ofcompression.This thesis compares compression algorithms on sensor data from motor controlunits in order to investigate which algorithm(s) are best suited to implement forthis application. The work aims to improve the possibilities of logging sensor dataand thus make the troubleshooting of the engine control units more efficient. Thiswas done by developing a system that performs compression on sampled sensorsignals and calculates the compression time and ratio.The results indicated that delta-of-delta compression performed better than xorcompression for the tested data sets. Delta-of-delta had a significantly bettercompression ratio while the differences between the algorithms regardingcompression time were minor. Delta-of-delta compression was judged to have goodpotential for implementation in engine control unit logging systems. The algorithmis deemed to be well suited for logging smaller time series during important events.For continuous logging of larger time series, further research is suggested in orderto investigate the possibility of improving the compression ratio further.

Page generated in 0.0526 seconds