• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 18
  • 5
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 59
  • 59
  • 17
  • 16
  • 15
  • 15
  • 12
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Análise experimental e analítica da fissuração de pavimentos de concreto continuamente armados em clima tropical. / Experimental and analytical analysis of continuously reinforced concrete pavements cracking in tropical weather.

Andréia Posser Cargnin 23 November 2016 (has links)
Os primeiros estudos sobre pavimentos de concreto continuamente armados (PCCA) foram desenvolvidos em zonas cujo clima característico é o temperado (EUA, Holanda e Bélgica), não se tendo estudos técnicos acerca do comportamento do pavimento em ambiente tropical. A premissa de funcionamento do PCCA está baseada na não execução de juntas de retração, obrigatórias em pavimentos de concreto simples (PCS), ou seja, as fissuras devido à retração do concreto ocorrem aleatoriamente, sendo controladas pela elevada taxa de armadura longitudinal disposta longitudinalmente ao longo de toda a extensão do pavimento. Como essa armadura não possui função estrutural, pois é colocada acima da linha neutra da placa, no banzo comprimido, sua função é manter as fissuras fortemente apertadas, garantindo suavidade ao rolamento e elevada transferência de carga (LTE), a qual ocorre pelo intertravamento dos agregados nas faces fissuradas, proporcionando assim um pavimento de alta durabilidade e que dispende baixíssimos custos com manutenção. No Brasil, a primeira experiência com PCCA teve início no ano de 2010, quando foram construídas quatro seções de 50 m de extensão cada, consideradas curtas em comparação aos 400 m de extensão de um PCCA rodoviário que podem ser alcançados ao final de um dia de trabalho. O monitoramento contínuo de tais seções mostrou haver uma diferença muito significativa de comportamento, comparado aos PCCA tradicionais, no que tange o tempo decorrido para estabelecimento do padrão de fissuração (a primeira fissura surgiu um ano após a construção), bem como espaçamento médio entre as fissuras, devido à curta extensão das placas e a inexistência de um sistema de ancoragem nas extremidades. Assim, para melhor compreender o comportamento de pavimentos de concreto com armadura contínua com padrões condizentes à realidade rodoviária em ambiente tropical, em janeiro de 2016, foi construído no campus da Universidade de São Paulo o primeiro PCCA de longa extensão do Brasil, com 200 m de comprimento. Foram empregados quatro diferentes tipos de concreto, variando o tipo de cimento e o tipo de agregado, bem como foram empregados aço galvanizado e aço comum. Para entender o comportamento do pavimento sob as condições climáticas brasileiras foram realizados três estudos: levantamento de fissuras (espaçamento e abertura), modelagem analítica do espaçamento entre fissuras através de modelos de previsão de retração em concreto e testes com FWD para avaliação da eficiência de transferência de carga (LTE) entre as fissuras. A análise do padrão de fissuração mostrou que o desenvolvimento das fissuras aconteceu conforme a literatura técnica, tendo início na primeira semana após a concretagem e atingindo aproximadamente 60% do número total de fissuras antes do primeiro mês. As seções centrais possuem o maior número de fissuras, pois estão ancoradas pelas seções de extremidade, onde o surgimento das fissuras é mais lento por conta da falta de ancoragem. As aberturas das fissuras mostraram-se maiores nas posições com aço galvanizado devido à menor aderência aço-concreto nesse caso, em comparação às posições com aço comum. O modelo de previsão de retração no concreto que melhor se aproximou do espaçamento médio desenvolvido em campo foi o modelo do Eurocode 2, com diferenças em torno de 30%, aproximadamente. As análises de LTE mostraram um desempenho muito satisfatório, apesar de a LTE nas regiões com aço galvanizado ter resultado menor do que a LTE nas regiões com aço comum. / The first studies on continuously reinforced concrete pavements (CRCP) were developed in areas in which the typical weather is temperate (United States, Netherlands and Belgium), with no technical studies carried out in tropical weather. CRCP structural premise is based on a slab without construction joints which are required in jointed plain concrete pavements (JPCP); i.e., CRCP cracks due to concrete shrinkage occur randomly being controlled by the high longitudinal reinforcement percentage, positioned longitudinally along the pavement length. As the longitudinal reinforcement has no structural role, because it is placed above the slab neutral axis, in the compression zone, its main function is to keep cracks strongly tight, ensuring a smooth ride and high load efficiency transfer (LTE) at cracks, which occurs through aggregates interlocking, thereby providing a highly durable pavement with low maintenance costs. The first experience with CRCP in Brazil started in 2010, when four experimental sections were constructed. Each section is 50 meters long, short when compared to the traditional CRCP that can extend for over 400 meters providing that concrete pouring does not stop. Continuous monitoring of these sections has shown that the short CRCP behaves differently from traditional CRCP, regarding the time taken for the cracking pattern full development (the first crack was visible on the surface one year after the construction), as well as average cracking space due to the slab\'s short extension and lack of anchorage. Therefore, in order to fully analyze the behavior of a traditional CRCP under tropical weather, in January 2016, the first long extension CRCP in Brazil was built, at the University of São Paulo campus, with 200 meters length. Four types of concrete were applied in the construction, varying cement and aggregate type. Galvanized and ordinary steel were used as well. To analyze the pavement behavior under Brazilian climatic conditions, three studies were carried out: cracks surveys (spacing and width), analytical modeling crack spacing through shrinkage prediction models and Falling Weight Deflectometer testing to evaluate the crack\'s load transfer efficiency (LTE). Cracking pattern analysis has shown cracks development consistent with technical literature. The first cracks appeared during the first week after concrete placement and, before the first month, about 60% of the total cracks number had developed. Central sections presented greatest number of cracks as they are anchored by the outer sections, where cracking occurs slower due to the lack of anchorage. Cracks width was higher in areas with galvanized steel due to the weaker steel-concrete bond, when compared to areas with common steel. The shrinkage prediction model for concrete that better approached the average field crack spacing was the Eurocode 2, with mean difference of 30%. LTE analysis has shown a quite satisfactory performance, even though LTE in areas with galvanized steel is lower than LTE in areas with common steel.
42

Vliv parametrů odpružení a tlumení na jízdní vlastnosti vozidla / The Effect of Springing and Damping Parameters on Vehicle Handling

Kopca, Filip January 2017 (has links)
The thesis describes function and characteristics of spring and damper, their particular way and margin of influence on vehicle behavior in selected riding maneuvers. The goal is to maintaining maximal grip, control, and achieve predictable vehicle handling.
43

Mechanical-Empirical Performance of U.S. 50 Joint Sealant Test Pavement

Sander, Jason Andrew 08 October 2007 (has links)
No description available.
44

Lateral response of stiff column-supported shallow foundations

Rivera Rojas, Alfonso Jose 15 May 2019 (has links)
The mechanisms that control the lateral response of stiff column-supported shallow foundations, resulting from the application of horizontal load on shallow foundations supported by stiff columns, are uncertain. Stiff columns constructed in soft clayey soil have been used to support retaining walls and in such cases, the lateral thrust applied behind these geotechnical structures is a source of horizontal loading. For seismic events, stiff columns constructed in soft clayey soil have been used to support shallow foundations subjected to horizontal load coming from the upper structure of buildings. Due to its practical applications, it has become important to understand the consequences of subjecting a shallow foundation supported by stiff columns to horizontal load by identifying the factors that control the lateral response of such systems. A series of centrifuge tests were carried out to examine the lateral response of stiff column-supported shallow foundations. The experimental trends suggested that the thickness of the coarse-granular mattress placed above the soil-column composite, called the Load Transfer Platform (LTP), controlled the lateral capacity and the overall lateral response of these systems. A numerical study using the finite element method confirmed the experimental trends. A parametric analysis was conducted with the purpose of investigating the influence of different geometry-based and material-based variables in the lateral response of these systems. The results of the parametric analysis further confirmed the importance of the thickness of the LTP in controlling the lateral response. The parametric results also emphasized the contribution of other variables to this lateral response, and these variables included the undrained shear strength of the soft clayey soil around the stiff columns, the stiff column diameter, and the spacing of the stiff columns after they are constructed in the soft clayey soil. / Doctor of Philosophy / Ground improvement is the process of improving the properties of weak soils. In practice, there are several ways to accomplish the ground improvement of weak soils. One way is to use stiff columns. Stiff columns are solid cylinders that are constructed in the weak soil in order to produce a stiff and strong soil-column composite capable of better supporting the square-shaped foundations of structures. Under horizontal load, there is uncertainty on the factors that control the lateral behavior of the stiff columns when used for the support of the square-shaped foundations of structures. An experimental and numerical approach was used to determine these factors and to understand their influence in the lateral behavior of such systems. The findings showed that the controlling factors of this lateral behavior included the thickness of a sand layer placed above the stiff columns, the diameter of the stiff columns, the spacing of the stiff columns after they are constructed in the weak soil, and the strength of the soil around the stiff columns. These findings will aid in improving the design of stiff columns used for the support of square-shaped foundations of structures subjected to horizontal load.
45

Análise da transferência de carga em estacas cravadas em argila mole à partir de provas de carga dinâmica de energia crescente / Load transfer analysis in driven piles in soft clay from increasing energy dynamic loading tests

Balech, Jean 31 March 2000 (has links)
A utilização de métodos de análise apoiados na Teoria da Equação da Onda, a partir da instrumentação de medidas dinâmicas, como controle do comportamento de estacas, tem evoluído continuamente nos últimos anos. Após importantes considerações sobre a prova de carga dinâmica de energia crescente e o mecanismo de transferência de carga, procedem-se análises CAPWAP em um caso real de obra com o objetivo de analisar o comportamento do sistema estaca-solo perante a aplicação de níveis crescentes de energia. São apresentados nesta dissertação, os resultados do comportamento de vários sistemas isolados estaca-solo em maciço de argila mole, submetidos à prova de carga dinâmica de energia crescente. São feitas análises de: transferência de carga, atrito lateral local, quake da ponta, tensões dinâmicas e correlação entre prova de carga estática e dinâmica. / The use of analysis methods to control pile behavior employing the Stress-Wave Theory from results of dynamic pile driving measurements has evolved in recent years. After important considerations about the increasing energy dynamic loading test and the load transfer mechanism, CAPWAP analyses are proceed in a pilework with objective of analyzing the behavior of the pile-soil system before the application of growing levels of energy. Therefore, they are presented in this dissertation, the results of the behavior of several isolated pile-soil systems in soft clay formation, submitted to the dynamic loading test of growing energy. Among the analyses, load transfer diagrams, local friction, quake, dynamic tensions, and the correlation between static and dynamic loading test are presented.
46

Análise do comportamento de estacas metálicas cravadas na bacia de Taubaté através de provas de carga dinâmica de energia crescente / Analysis of the behavior of steel piles driven in Taubaté basin by dynamic loading test with increasing energy

Ávila, Igor Adolfo de 21 November 2001 (has links)
Neste trabalho estudou-se o comportamento de estacas metálicas, do tipo perfil soldado, cravadas na formação Tremembé, na Bacia de Taubaté, em São Paulo. A formação Tremembé é cosntituída por folhelhos pirobetuminosos, cujo mineral predomiante é a montmorilonita. Foram analisados os resultados de provas de carga dinâmica de energia crescente em 14 estacas, sendo que, em todas elas, sistema estaca-solo foi levado à ruptura. Por meio da análise de 101 golpes, examinou-se o comportamento estático, segundo o modelo CAPWAPC, e o comportamento dinâmico do sistema. O comportamento estático foi investigado com base na aplicabilidade das fórmulas dinâmicas para a previsão de resistência. O mecanismo de transferência de carga foi estudado mediante a identificação de formas típicas de curvas de resistência estática mobilizadas pelo fuste e pela ponta, para o caso analisado. O comportamento dinâmico foi investigado na análise da ruptura e pós ruptura do sistema, pela aplicação do Princípio de Hamilton ao impacto do martelo. Verificou-se que o mecanismo de transferência de carga do sistema estaca-solo foi fortemente influenciado pela variabilidade das camadas de solo atravessadas pelo elemento estrutural de fundação. A quebra da estrutura do folhelho pelo processo de cravação também interferiu na transferência de carga. Constatou-se a aplicabilidade do repique como instrumento de controle de cravação de estacas metálicas. / In this work the behavior of steel piles driven in Tremembé formation, in the Taubaté Basin, São Paulo was studied. The Tremembé formation is constituted by bituminous shale, which predominant mineral clayey component is the mo ntmorillonite. The dynamic loading tests results with increasing energy in 14 piles were analyzed, with all of the tests taken to system rupture. Through the analysis of 101 blows it was studied the static behavior, according to the CAPWAPC model, and the dynamic behavior of the system. The use of the dynamic and semi-empiric static formula for resistance prediction was evaluated. The load transfer mechanisms were studied by pattern form of mobilized static resistance curves by the shaft and toe. The application of Hamilton\'s principle to hammer impact allowed to analyze the failure and post failure of the pile-soil system. It was observed that the pile-soil load transfer mechanism was strongly influenced by the resistance variability of crossed soil layers by the structural element of foundation. The material break during the driving process also interfered in load transfer mechanism. The use of rebound as instrument of steel pile driving control shows reliable.
47

Análise do comportamento de estacas metálicas cravadas na bacia de Taubaté através de provas de carga dinâmica de energia crescente / Analysis of the behavior of steel piles driven in Taubaté basin by dynamic loading test with increasing energy

Igor Adolfo de Ávila 21 November 2001 (has links)
Neste trabalho estudou-se o comportamento de estacas metálicas, do tipo perfil soldado, cravadas na formação Tremembé, na Bacia de Taubaté, em São Paulo. A formação Tremembé é cosntituída por folhelhos pirobetuminosos, cujo mineral predomiante é a montmorilonita. Foram analisados os resultados de provas de carga dinâmica de energia crescente em 14 estacas, sendo que, em todas elas, sistema estaca-solo foi levado à ruptura. Por meio da análise de 101 golpes, examinou-se o comportamento estático, segundo o modelo CAPWAPC, e o comportamento dinâmico do sistema. O comportamento estático foi investigado com base na aplicabilidade das fórmulas dinâmicas para a previsão de resistência. O mecanismo de transferência de carga foi estudado mediante a identificação de formas típicas de curvas de resistência estática mobilizadas pelo fuste e pela ponta, para o caso analisado. O comportamento dinâmico foi investigado na análise da ruptura e pós ruptura do sistema, pela aplicação do Princípio de Hamilton ao impacto do martelo. Verificou-se que o mecanismo de transferência de carga do sistema estaca-solo foi fortemente influenciado pela variabilidade das camadas de solo atravessadas pelo elemento estrutural de fundação. A quebra da estrutura do folhelho pelo processo de cravação também interferiu na transferência de carga. Constatou-se a aplicabilidade do repique como instrumento de controle de cravação de estacas metálicas. / In this work the behavior of steel piles driven in Tremembé formation, in the Taubaté Basin, São Paulo was studied. The Tremembé formation is constituted by bituminous shale, which predominant mineral clayey component is the mo ntmorillonite. The dynamic loading tests results with increasing energy in 14 piles were analyzed, with all of the tests taken to system rupture. Through the analysis of 101 blows it was studied the static behavior, according to the CAPWAPC model, and the dynamic behavior of the system. The use of the dynamic and semi-empiric static formula for resistance prediction was evaluated. The load transfer mechanisms were studied by pattern form of mobilized static resistance curves by the shaft and toe. The application of Hamilton\'s principle to hammer impact allowed to analyze the failure and post failure of the pile-soil system. It was observed that the pile-soil load transfer mechanism was strongly influenced by the resistance variability of crossed soil layers by the structural element of foundation. The material break during the driving process also interfered in load transfer mechanism. The use of rebound as instrument of steel pile driving control shows reliable.
48

Análise da transferência de carga em estacas cravadas em argila mole à partir de provas de carga dinâmica de energia crescente / Load transfer analysis in driven piles in soft clay from increasing energy dynamic loading tests

Jean Balech 31 March 2000 (has links)
A utilização de métodos de análise apoiados na Teoria da Equação da Onda, a partir da instrumentação de medidas dinâmicas, como controle do comportamento de estacas, tem evoluído continuamente nos últimos anos. Após importantes considerações sobre a prova de carga dinâmica de energia crescente e o mecanismo de transferência de carga, procedem-se análises CAPWAP em um caso real de obra com o objetivo de analisar o comportamento do sistema estaca-solo perante a aplicação de níveis crescentes de energia. São apresentados nesta dissertação, os resultados do comportamento de vários sistemas isolados estaca-solo em maciço de argila mole, submetidos à prova de carga dinâmica de energia crescente. São feitas análises de: transferência de carga, atrito lateral local, quake da ponta, tensões dinâmicas e correlação entre prova de carga estática e dinâmica. / The use of analysis methods to control pile behavior employing the Stress-Wave Theory from results of dynamic pile driving measurements has evolved in recent years. After important considerations about the increasing energy dynamic loading test and the load transfer mechanism, CAPWAP analyses are proceed in a pilework with objective of analyzing the behavior of the pile-soil system before the application of growing levels of energy. Therefore, they are presented in this dissertation, the results of the behavior of several isolated pile-soil systems in soft clay formation, submitted to the dynamic loading test of growing energy. Among the analyses, load transfer diagrams, local friction, quake, dynamic tensions, and the correlation between static and dynamic loading test are presented.
49

Reconfiguration Algorithms For Distribution Automation

Rao, Kavalipati S Papa 08 1900 (has links) (PDF)
No description available.
50

[pt] DIMENSIONAMENTO DE ESTOQUES DE TRANSFORMADORES EM SISTEMAS DE POTÊNCIA CONSIDERANDO FALHAS REPARÁVEIS E CATASTRÓFICAS / [en] SIZING OF TRANSFORMER STOCKS IN POWER SYSTEMS CONSIDERING REPAIRABLE AND CATASTROPHIC FAILURES

VENUS LIRIA SILVA MENDES 20 August 2020 (has links)
[pt] Transformadores de subestações de distribuição requerem uma atenção especial pelos altos custos, longos tempos de reposição e por impactarem, quando falham, diretamente na confiabilidade da rede, provocando assim a interrupção de inúmeros usuários. Em geral, as subestações são projetadas com transformadores em paralelo, de forma que a carga pico possa ser atendida ainda que um transformador do grupo esteja avariado. No entanto, esta solução requer investimentos elevados. Uma alternativa consiste no compartilhamento de estoques de transformadores reservas e subestações móveis. O dimensionamento dos estoques deve ser feito com cautela, pois, um grande número de equipamentos pode aumentar desnecessariamente os custos de investimento, e um estoque insuficiente pode diminuir a confiabilidade do sistema e aumentar seus custos operacionais. Esta dissertação apresenta duas metodologias para o dimensionamento do estoque, o método de Markov e a simulação Monte Carlo, os quais são comparados quanto aos seus resultados e características quando aplicados a um mesmo sistema. Ambos os modelos foram utilizados para dimensionar o estoque para falhas do tipo catastróficas e reparáveis, separadamente. O método probabilístico baseado na simulação Monte Carlo foi aplicado a um grupo de transformadores da classe 115 kV e 15 MVA, visando demonstrar a capacidade da metodologia de encontrar soluções condizentes do ponto de vista técnico e econômico. / [en] Substation distribution transformers require special attention for their high costs, long replacement times and for impacting, when they fail, directly on the reliability of the electric network, thus causing the interruption of several costumers. In general, substations are designed with transformers in parallel, so that the peak load can be met even if a transformer in the group is damaged. However, this solution requires high investments. An alternative is to share stocks of spare transformers and mobile substations. Stock sizing should be done with caution, as a large number of equipment can unnecessarily increase investment costs, and insufficient stock can decrease system reliability and increase operating costs. This dissertation presents two methods for stock dimensioning based on Markov modeling and on Monte Carlo simulation, which are compared in terms of their results and characteristics when applied to the same system. Both models were used to scale the stock for catastrophic and repairable failures, separately. The probabilistic method based on the Monte Carlo simulation was applied to a group of 115 kV and 15 MVA class transformers, aiming to demonstrate the method s ability to find solutions that are technically and economically compatible.

Page generated in 0.0634 seconds