• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 26
  • 7
  • 6
  • 5
  • 5
  • 4
  • 1
  • Tagged with
  • 119
  • 119
  • 28
  • 16
  • 14
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Quantitative assessment of bone quality using image guided failure analysis

Green, Richard January 2012 (has links)
Bone quality influences bone strength with important consequences for osteoporosis, fracture risk and dental implant success. Whilst imaging that is capable of capturing bone structure in 3D is becoming more common, quantitative clinical measures of bone quality rely on bone quantity, not structure. If bone quality could be more accurately measured, and the influence of bone architecture better understood, strength may be better predicted. This thesis presents methods for making structural comparisons between successive micro-CT images of loaded bone and explores the limitations of these. I present a novel method to detect where damage occurs in loaded rat vertebrae based on multiscale rigid registration and difference measures. Together these methods represent a quantitative approach to image guided failure analysis. Time-lapsed micro-CT images of 14 successively loaded rat vertebrae were acquired and damaged regions found using these. Using a random forest classifier I tested whether the damaged regions could be predicted by several commonly used structural measures (bone area and volume), three-dimensional texture measures (co-occurrence matrices and fractal dimension) and a more novel type of architectural measure (based on the structure tensor). A combination of parameters was able to predict damage regions with specificities in the range 70-90% and sensitivities of 60-70%.Using ovariectomised rats as a model of osteoporosis I have performed a pilot experiment to investigate how changes in bone quality might effect our results. The wider applicability of my methods are demonstrated by applying them to dental cone beam images of healthy and osteoporotic patients.
42

Phenotype characterization of lung structure in inbred mouse strains using multi modal imaging techniques

Namati, Jacqueline Thiesse 01 May 2009 (has links)
Research involved in modeling human lung disease conditions has provided insight into disease development, progression, and treatment. In particular, mouse models of human pulmonary disease are increasingly utilized to characterize lung disease conditions. With advancements in small animal imaging it is now possible to investigate the phenotypic differences expressed in inbred mouse strains in vivo to investigate specific disease conditions that affect the lung. In this thesis our aim was to generate a comprehensive characterization of the normative mouse lung phenotypes in three of the most utilized strains of mice, C57BL/6, A/J, and BALB/c, through imaging techniques. The imaging techniques that we utilized in this research included micro-CT, a custom Large Image Microscope Array (LIMA) system for 3D microscopy, and classical histology. Micro-CT provided a non-destructive technique for acquiring in vivo and fixed lung images. The LIMA 3D microscopy system was utilized for direct correspondence of the gold standard histology images as well as to validate the anatomical structures and measurements that were extracted from the micro-CT images. Finally, complete lung histology slices were utilized for assessment of the peripheral airspace structures that were not resolvable using the micro-CT imaging system. Through our developed imaging acquisition and processing strategies we have been able to successful characterize important phenotypes in the mouse lung that have not previously been known as well as identify strain variations. These findings will provide the scientific community with valuable information to be better equipped and capable of pursuing new avenues of research in investigating pulmonary disease conditions that can be modeled in the mouse.
43

Systemic POMC Overexpression Increases Visceral Fat Accumulation in Mice

Tang, Chia-Hua 16 February 2011 (has links)
Proopiomelanocortin (POMC) is a polypeptide precursor with 241 amino acid residues which undergoes extensive post-translational modification to yield a range of smaller, biological active peptides including £\-, £] -, £^-melanocyte-stimulating hormone (£\-MSH, £]-MSH, £^-MSH )¡A£]-endorphin (£]-EP) and adrenocorticotrophic hormone (ACTH). POMC-derived peptides play important roles in appetite and energy homeostasis. Recently, the peripheral POMC system is under active investigation to delineate their pathogenic roles in metabolic diseases such as Cushing¡¦s syndrome and obesity. In the present study, we utilized adenovirus gene delivery system to achieve systemic POMC overexpression in adult C57/BL6 mice for at least 30 days. Subsequently, the plasma and abdominal adipose tissue of mice were collected and analyzed by biochemical assays and weight determination respectively. POMC overexpression did not increase in the food uptake and body weight. These results imply that local POMC gene delivery induced the visceral fat accumulation and altered the metabolism in mice. It was observed that systemic POMC overexpression significantly elevated the triglyceride and the cholesterol levels in mice. However, POMC gene delivery also induced elevated plasma glucose concentration at weeks 1-4 and evoked glucose tolerance in mice at week 4. Interestingly, insulin resistance was readily detected in POMC-transduced in mice at as early as week 1. Besides, Micro-CT scanning and histological studies demonstrated that the visceral fat was significantly increased in POMC over-expressing mice compared with control animals. These data indicate that hepatic POMC gene delivery causes systemic ACTH rise and insulin resistance, which recapitulates the clinical features of Cushing¡¦s syndrome. In summary, POMC gene delivery induces systemic POMC overexpression and results in visceral fat accumulation and insulin resistance, which may facilitates a mice model for Cushing¡¦s-like metabolic syndrome.
44

Hydrogel therapy for re-synostosis based on the developmental and regenerative changes of murine cranial sutures

Hermann, Christopher Douglas 23 May 2012 (has links)
Craniosynostosis is the premature fusion of one or more cranial sutures in the developing skull. If left untreated, craniosynostosis can result in developmental delays, blindness, deafness, and other impairments resulting from an increase in the intracranial pressure. In many cases, the treatment consists of complex calvarial vault reconstruction with the hope of restoring a normal skull appearance and volume. Re-synostosis, the premature re-closure following surgery, occurs in up to 40% children who undergo surgery. If this occurs, a second surgery is needed to remove portions of the fused skull in an attempt to correct the deformities and/or relieve an increase in intracranial pressure. These subsequent surgeries are associated with an incredibly high incidence of life threatening complications. To address this unmet clinical need we have developed strategies to delay the post-operative bone growth in a clinically relevant murine model of re-synostosis. The overall objective of this thesis was to develop a hydrogel based therapy to delay rapid bone regeneration in a murine model of re-synostosis. The overall hypothesis was that delivery of key BMP inhibitors involved in regulating normal suture development and regeneration will delay the rapid bone growth that in seen in a pediatric murine model of re-synostosis. The overall approach is to use micro-computed tomography (µCT) to determine the time course of suture fusion and to identify genes associated with key developmental time points, to develop a pediatric specific mouse model that displays rapid re-synostosis, and lastly to develop a hydrogel based therapy to delay the re-synostosis of this cranial defect.
45

Data acquisition for modeling and visualization of vascular tree

Mondy, William Lafayette 01 June 2009 (has links)
Data can be acquired from tissue's vascular structure and used for modeling and visualization. To acquire data from a vascular tree, we make its structure available for the gathering of data by separating it from the structures of surrounding tissues, which includes the capillary structure. The capillary structure contains important information, but, because of its size, is the most difficult to acquire data from. In this work, we look at methods for contrasting the vascular structure from surrounding tissues, and focus on the use of corrosion casting for this procedure. We collected image data using micro-computer tomography (micro-CT) and converted data into stereolithography models. Models were imported into computer aided design (CAD) software, which was used to further process the models in order to ensure that the necessary structures were in place for the recreation of the capillary structures' relationship to targeted cell systems. Recreating the cell system-capillary system relationship is the reason building this model is so important. It is this relationship that we seek to model so that, in the future, we can create designs that guide the fabrication of three-dimensional (3D) scaffolding, which mimic capillary patterns with supportive structure that serve as an extracellular matrix for 3D tissue engineering. This method had been designed to enhance a variety of therapeutic protocols including, but not limited to, organ and tissue repair, systemic disease mediation and cell/tissue transplantation therapy.
46

Methods for reduced platen compression (RPC) test specimen cutting locations using micro-CT and planar radiographs

Lemmon, Heber 30 September 2004 (has links)
This study looks at improving reduced platen compression (RPC) specimen preparation procedures by developing a better method for locating the ideal RPC specimen on each bone. These improvements are aimed at decreasing the amount of time required to complete an RPC analysis and improving the quality of the obtained results. High-resolution micro-CT scans are used to gain a better understanding of rat long bone anatomy by quantifying the location, shape, and orientation of the growth plate, primary spongiosa, and secondary spongiosa. Micro-CT analysis shows that there are easily identifiable external landmarks on the anterior side of both tibias and femurs that identify the end of the growth plate and the point at which the top of an ideal RPC specimen should be located. The landmarks are the most proximal tip of the patellar surface for the femur and the base of the tibial tuberosity for the tibia. This study also analyzes the effect of variations in the actual RPC specimen location from the ideal location and the effect of different platen sizes on test results using BMD as a surrogate for mechanical properties. The analysis shows that the BMD increases as the target RPC specimen location approaches the growth plate and decreases on moving away from the growth plate. The study also indicates that consistency is necessary when obtaining RPC specimens to avoid error due to variation from the specified landmark. Additionally, the BMD decreased as the diameter of the platen is reduced. Choosing platen size then becomes a trade off between testing the greatest amount of cancellous bone possible and potentially higher load sharing by the cortical shell with larger platen sizes as well as the risk of compressing cortical bone during the test.
47

Effects of geometric and material property changes on the apparent elastic properties of cancellous bone

LIEVERS, WILLIAM BRENT 24 April 2009 (has links)
Osteoporosis is a disease characterized by reduced bone mass and reduced bone quality. This deterioration manifests itself in osteoporotic fractures at skeletal sites containing large proportions of cancellous bone (ie. forearm, hip, spine). Given the costs associated with these fractures, improvements in our ability to model and predict the behaviour of cancellous bone would be of great financial and social benefit to society. This thesis makes contributions in three areas within the much larger goal of developing a comprehensive model for describing the mechanical behaviour of cancellous bone. Since the accuracy of model predictions can only be as good as the test data against which it is compared, the effect of experimental artifacts introduced by specimen geometry is examined for cored samples. The apparent elastic modulus of cancellous bone is found to be relatively insensitive to specimen (or gauge) length, such that it can be reduced below the recommended 2:1 aspect ratio without introducing detectable artifact. Conversely, apparent modulus is found to be much more sensitive to specimen diameter. The role of water is also examined. Dehydration at room temperature was found to increase the apparent elastic modulus by roughly 14%. This net increase results from the competing effects of an increased tissue modulus and a decreased bone volume fraction due to shrinkage. Finally, preliminary work is presented which attempts to relate micro-CT voxel intensity and locally measured nanoindentation moduli, in order to provide an experimental basis for assigning heterogeneous material properties to finite element method (FEM) models. / Thesis (Ph.D, Mechanical and Materials Engineering) -- Queen's University, 2009-04-24 14:28:17.772
48

Experimental investigation of two-phase flow properties of small core samples

Olafuyi, Olalekan Adisa, Petroleum Engineering, Faculty of Engineering, UNSW January 2008 (has links)
This thesis presents an experimental investigation of two-phase flow properties of porous rock samples having different scales ranging from micro-CT imaging to conventional core plug scales. Advances in micro-CT imaging of porous materials provide the opportunity to extract representative networks from the images. This improves the predictive capability of porescale network models to predict multiphase flow properties. However, all these predictions need to be validated with laboratory data. Micro-CT imaging is currently limited to small sample sizes, having bulk volumes of the order of 0.1 cm??. Conventional core plugs, however, have sizes several orders of magnitude larger than that (bulk volumes of 10 cm?? or larger). The aim of this thesis is to investigate the scale effect on laboratory data and to provide reliable experimental data which can be used to test the predictive value of microCT based network models. Berea and Bentheim sandstones and Mount Gambier carbonate were used in the experiments. The core samples were thoroughly cleaned in order to obtain strongly, uniform water-wet conditions. Simple well-characterized fluid systems were chosen in the experiments: Air-brine fluid-system for drainage capillary pressure, resistivity index and spontaneous imbibition experiments while oil-brine fluid-system for wettability and relative permeability measurements. Drainage capillary pressure, resistivity index, relative permeability and spontaneous imbibition measurements were made on the cores having bulk volumes ranging from 0.1 to 12 cm??. Previous studies have shown that experiments at this scale are still lacking. The wettability was tried to keep strongly water-wet for all experiments. The experimental results show that the measurements of drainage capillary pressure, and resistivity index and spontaneous imbibition on small core samples, having similar scales as micro-CT imaging can be made accurately in the laboratory. The measurement of relative permeability remains challenging. This thesis concludes that commonly used homogeneous rock types (Berea and Bentheim sandstones and Mt. Gambier carbonate) can be considered to be sufficiently homogeneous from the pore to core scale based on the two-phase flow properties examined in this study. Hence, laboratory data taken from these rocks using conventional core plugs can be used to calibrate micro-CT based network models for multiphase flow properties.
49

Micro computed tomography assessment of tumor size in breast cancer compared to histopathological examination

Sarraj, Wafa Mowafak 12 March 2016 (has links)
PURPOSE: The purpose of this study was to assess the ability of Micro Computed Tomography (Micro CT) to measure primary tumor size in breast lumpectomy specimens, as compared to the histopathological measurement. METHODS: This was a diagnostic study involving women who were scheduled to have breast lumpectomy surgery at the Massachusetts General Hospital (MGH) Department of surgery from June 2011 - September 2011. Those who met the study eligibility criteria were recruited to participate in the study. The study was approved by the MGH Institutional Review Board (IRB). All the participants provided consent prior to their participation in the study. The lumpectomy specimens of 45 subjects were scanned by Micro CT scan for no longer than 15 minutes, they were then delivered to the gross pathology lab for processing via the standard pathological protocol. Later on, the maximum dimension of the invasive breast tumor was obtained from the Micro CT image and was compared to the corresponding pathology report for each subject. RESULTS: We found that Micro CT tends to overestimate the breast malignant tumor size. However, there were few differences in T-stage classification between Micro CT and pathology. Overall, Micro CT demonstrated good agreement with pathological tumor size and staging. For Invasive ductal carcinoma, Micro CT showed a substantial agreement with pathological tumor size and staging. However, Micro CT showed no agreement with pathological tumor size and staging for invasive lobular carcinoma. CONCLUSIONS: Micro CT is a promising modality in measuring and staging the invasive ductal carcinoma.
50

Avaliação volumétrica da obturação dos canais radiculares realizada com diferentes cimentos e técnicas, por meio de microtomografia / Volumetric evaluation of root canal fillings performed with different sealers and techniques through microtomography

Vanessa Lessa Cavalcanti de Araujo 21 January 2014 (has links)
O sucesso do tratamento endodôntico está associado não só com a limpeza e a instrumentação do sistema de canais radiculares (SCR), mas com a capacidade de selamento do material obturador principalmente do terço apical. O objetivo do presente estudo in vitro foi analisar o volume de guta-percha e de cimento endodôntico no milímetro apical das obturações, utilizando diferentes cimentos e técnicas de condensação. Para tanto, 64 incisivos centrais superiores foram preparados com instrumentos rotatórios de NiTi até o diâmetro cirúrgico #60.02, e então distribuídos aleatoriamente em quatro grupos. Para cada um usou-se um cimento diferente, a saber: Endofill, Sealer 26, AH Plus e Sealapex. E para cada cimento utilizado, metade dos dentes foi obturada pela técnica de condensação lateral ativa (n=8), e a outra metade, pela técnica da condensação lateral passiva (n=8). Feitas as obturações, os dentes foram submetidos ao exame tomográfico com o uso do microtomógrafo SkyScan 1174 v2. As imagens foram reconstruídas pelo programa NRecon e em seguida foi avaliado o parâmetro tridimensional do volume de cimento e guta-percha no milímetro apical, por meio do programa CTan. A análise de variância a dois critérios para o volume de guta-percha demonstrou haver diferença estatisticamente significante para o fator de variação Cimento endodôntico (p>0,05). Por meio do teste Tukey, observou-se que o grupo obturado com o Sealer 26 apresentou maior volume de guta-percha no milímetro apical do comprimento de trabalho quando comparado ao Endofill que se apresentou com menor volume. Já a análise de variância para o volume de cimento endodôntico demonstrou haver diferença estatisticamente significante para o fator de variação Cimento endodôntico (p<0,05), Técnica obturadora (p<0,05) e pelas interações dos fatores (p<0,05). O teste Tukey para o fator de variação Cimento endodôntico demonstrou que o grupo obturado com o Sealapex apresentou menor volume de cimento no milímetro estudado quando comparado ao grupo obturado com AH Plus e Sealer 26, que evidenciaram maior volume de cimento. Em relação ao fator de variação Técnica obturadora, a condensação lateral ativa apresentou menor volume de cimento comparada técnica passiva. Pode-se concluir que o maior volume de guta-percha foi encontrado nos dentes obturados com o cimento endodôntico Sealer 26, semelhantes aos obturados com Sealapex e AH Plus, independentemente da técnica de condensação. O menor volume de cimento endodôntico foi encontrado no grupo obturado com Sealapex, semelhante ao grupo obturado com o Endofill. Em relação à técnica obturadora, a condensação lateral ativa apresentou menor volume de cimento quando comparada à passiva. / The success of endodontic treatment is associated not only with the cleaning and the instrumentation of the root canal system (RCS) but also with the sealing ability mainly in the apical third of the filling material. The aim of this in vitro study was to analyze the volume of gutta-percha and sealer in the apical millimeter of the fillings, using different obturation technique and sealers. For that purpose, 64 maxillary central incisors were prepared with NiTi rotary instruments until the surgical diameter of #60.02, and then divided randomly into four groups. For each group, different sealers were used, such as Endofill, Sealer 26, AH Plus and Sealapex. And for each sealer used, half the teeth were obturated using an active lateral condensation technique (n=8), and the other half by passive lateral condensation technique (n=8). After the fillings procedures, samples were examined by SkyScan 1174 v2 micro-CT. Images were reconstructed by NRecon software, and then the dimensional parameter of the volume of sealer and gutta-percha at the apical millimeter was evaluated through the CTan program. The ANOVA Two-Way results for the analysis of the volume of guttapercha showed a statistically significant difference for endodontic sealer factor (p>0,05). The Tukey test showed that the group filled with Sealer 26 had higher volume of gutta-percha at the apical millimeter of working length when compared to that of the Endofill, which presented lower volumes. However, the ANOVA Two-Way analysis for the volume of sealer, showed a statistically significant difference for the endodontic sealer factor (p<0.05), obturation technique (p<0.05) and between the interactions of the factors (p<0.05). The Tukey test for the Sealer endodontic variation factor showed that the group filled with Sealapex had the lowest volume of sealer in the studied millimeter when compared to the group filled by AH Plus and Sealer 26, which had the highest volume of sealer. Regarding the filling technique variation factor, the active lateral condensation technique showed lower sealer volume than passive. It can be concluded that the higher volume of gutta-percha was found in teeth filled with sealer Sealer 26, similar to Sealapex and AH Plus, regardless of the technique of condensation. The lowest volume of sealer was found in the group filled with Sealapex, similar to the group filled with Endofill. Regarding the obturation technique, the active lateral condensation technique showed lowest volume of sealer than the passive.

Page generated in 0.0445 seconds