• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 57
  • 56
  • 34
  • 17
  • 9
  • 5
  • 5
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 217
  • 217
  • 217
  • 75
  • 65
  • 57
  • 55
  • 55
  • 54
  • 54
  • 53
  • 45
  • 44
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Voltametrické a amperometrické stanovení nitrofenolů pomocí borem dopované diamantové filmové elektrody / Voltammetric and Amperometric Determination of Nitrophenols Using Boron-Doped Diamond Film Electrode

Karaová, Jana January 2018 (has links)
Presented Ph.D. Thesis is focused on the use of the boron-doped diamond (BDD) electrodes for voltammetric and amperometric determination of selected nitrophenols: 2-nitrophenol (2NP), 4-nitrophenol (4NP), and 2,4-dinitrophenol (2,4DNP). These compounds are listed as "priority pollutants" by United States Environmental Protection Agency (US EPA) due to their negative impact on living organisms and are mainly used in agriculture as plant growth stimulators. BDD electrodes are used for determination of wide range of electrochemically both reducible and oxidisable organic compounds and have become a popular electrode material thanks to its commercial availability and excellent mechanical and electrochemical properties. A differential pulse voltammetric method was developed for the determination of 2NP, 4NP and 2,4DNP at a BDD film electrode using electrochemical reduction and of 4NP and 2,4DNP using electrochemical oxidation. The method was successfully applied for the direct determination of these compounds in drinking and river water in the concentration range from 4×10-7 to 2×10-5 mol.L-1 . To improve the limit of quantification, a preconcentration by solid phase extraction from 100 mL (drinking and river water) and 1000 mL (drinking water) of water samples was used with limit of determination...
212

Rychlé metody analýzy migrantů z materiálů ve styku s potravinami / Fast methods for analysis of migrants from food-contact materials

Vavrouš, Adam January 2020 (has links)
(AJ) Food contact materials pose a risk to human health due to a variety of contaminants which they can release into food. These compounds, migrants, include aromatic hydrocarbons, dialkyl phthalates, bisphenols, printing ink photoinitiators, and perfluoroalkyl compounds. The determination of all these substances can be expensive and time-consuming since universally applicable analytical approaches are not available nowadays. This work attempted to develop methods for the simultaneous determination of migrants from all of the mentioned groups in paper-based food contact materials and fatty food. A total of 68 contaminants were studied in paper products using liquid chromatography and gas chromatography coupled with tandem mass spectrometry detection. All analytes were isolated simultaneously using the modified "QuEChERS" method. This method demonstrated acceptable recovery and repeatability for most analytes in the validation study; LOQs ranged from 1.3 to 220 µg/kg. Analysis of 132 real paper products confirmed the occurrence of almost all studied analytes, which were often present in complex mixtures and at concentrations up to 628 mg/kg. A total of 41 potential contaminants were monitored in fatty foods by liquid chromatography with tandem mass detection. Contamination of the mobile phase by...
213

Rychlé metody analýzy migrantů z materiálů ve styku s potravinami / Fast methods for analysis of migrants from food-contact materials

Vavrouš, Adam January 2020 (has links)
(AJ) Food contact materials pose a risk to human health due to a variety of contaminants which they can release into food. These compounds, migrants, include aromatic hydrocarbons, dialkyl phthalates, bisphenols, printing ink photoinitiators, and perfluoroalkyl compounds. The determination of all these substances can be expensive and time-consuming since universally applicable analytical approaches are not available nowadays. This work attempted to develop methods for the simultaneous determination of migrants from all of the mentioned groups in paper-based food contact materials and fatty food. A total of 68 contaminants were studied in paper products using liquid chromatography and gas chromatography coupled with tandem mass spectrometry detection. All analytes were isolated simultaneously using the modified "QuEChERS" method. This method demonstrated acceptable recovery and repeatability for most analytes in the validation study; LOQs ranged from 1.3 to 220 µg/kg. Analysis of 132 real paper products confirmed the occurrence of almost all studied analytes, which were often present in complex mixtures and at concentrations up to 628 mg/kg. A total of 41 potential contaminants were monitored in fatty foods by liquid chromatography with tandem mass detection. Contamination of the mobile phase by...
214

Analyse d’hormones stéroïdiennes par spectrométrie de masse dans les eaux du robinet, de surface et les eaux usées

Goeury, Ken 02 1900 (has links)
Il apparaît au grand jour que de nombreuses substances telles que les perturbateurs endocriniens sont introduites quotidiennement dans l’environnement. Ces molécules organiques bien souvent d’origine anthropique peuvent être employées dans d’innombrables circonstances : pharmaceutique, médecine, agriculture, cosmétique, agroalimentaire pour citer quelques exemples. Parmi ce large panel de composés, se trouvent les hormones stéroïdiennes. Un certain nombre de maladies et de modifications aussi bien comportementales que physiologiques tant chez l’humain que sur la faune aquatique sont attribuées à l’usage et aux rejets chroniques de ces perturbateurs endocriniens. Il est donc indispensable de développer une approche portée sur la prévention et l’étude des niveaux de contamination selon un seul maître-mot : précaution. Dans ce contexte, ce projet de doctorat visait à développer de nouvelles méthodes de détection des hormones stéroïdiennes à niveau ultra-trace dans diverses matrices environnementales. La sélection des composés ciblés dans ce projet s’est basée sur la nouvelle liste de perturbateurs endocriniens prioritaires de l’agence de protection de l’environnement des États-Unis (US EPA), récemment élargie à d’autres classes de substances dont le bisphénol A. Les méthodes analytiques ont été développées non seulement dans l’eau du robinet (EPA 539), mais également dans d’autres matrices plus complexes (eaux de surface, eaux usées). Commune à l’ensemble des procédures testées, la phase de validation analytique a permis de vérifier la conformité avec les exigences de performance de l’EPA. La première méthode mise au point repose sur une pré-concentration rapide de l’échantillon par extraction sur phase solide en ligne (on-line SPE) couplée à la chromatographie liquide à ultra-haute performance (UHPLC) et à la spectrométrie de masse en tandem (MS/MS). La méthode validée présente de nombreux avantages—reproductibilité, automatisation, temps d’analyse minimal, logistique réduite et surtout des limites de détection de 0,10 ng·L-1 à 7,5 ng·L-1 selon les différentes matrices étudiées. Cette méthode apparaît particulièrement adaptée pour la détection des hormones dans les eaux usées, en lien avec les plus fortes concentrations attendues. Cependant, il est apparu pertinent d’améliorer encore la sensibilité des méthodes dans certains contextes, notamment dans le cadre des iv analyses d’eau de surface, compte tenu des critères de qualité applicables. La principale modification fut apportée au niveau de l’extraction et de la purification des échantillons. Amendée à la faveur des différentes matrices, l’étape d’extraction par SPE hors-ligne automatisée (off-line SPE) a permis d’atteindre des limites de détection adéquates variant de 0,010 ng·L-1 à 6,0 ng·L-1 dépendamment de la matrice et du composé. Un aspect original de cette étude a consisté à étudier de façon plus systématique les facteurs de robustesse de la méthode lorsque soumise à certaines variations, tant au niveau de l’analyse instrumentale (phases mobiles, volume d’injection) que des protocoles (emploi de différents agents de conservation, par exemple). L’analyse de la phase dissoute ne saurait être suffisante pour comprendre le devenir environnemental des perturbateurs endocriniens dans les milieux aquatiques, notamment leur distribution. Dans cette optique, la phase particulaire en suspension dans la colonne d’eau (SPM) fut également étudiée après optimisation et validation de la méthode d’extraction. Les limites de détection obtenues étaient comprises entre 0,10 ng/g et 3,0 ng/g, un degré de performance adéquat au regard des teneurs attendues dans l’environnement. De telles méthodes ne trouveraient pas de fondement si elles n’étaient pas employées à l’analyse d’échantillons réels. C’est pourquoi, pour chaque méthode développée, une série d’échantillons d’eau a été analysée pour toutes les matrices étudiées. La quantification des hormones stéroïdiennes a permis de rendre compte des niveaux de concentrations retrouvés dans l’environnement. Une étude saisonnière d’un cours d’eau a également été réalisée durant quatre saisons (hiver, printemps, été et automne) afin d’évaluer les éventuelles variations saisonnières en termes d’occurrence et de concentration. / It is now admitted that many substances such as endocrine disruptors are released daily into the environment. This process can be of natural origin but is predominantly linked to human activity. Endocrine disruptors originate from numerous fields: medicine, agriculture, cosmetics, and the food industry, to name a few. Steroid hormones belong to this wide array of compounds. A significant number of human diseases and behavioral and physiological changes in both humans and aquatic life have been attributed to the use and chronic release of these endocrine disruptors. The effects of such a cocktail of substances are difficult to understand and evaluate. To date, the synergistic mechanisms or the potential cumulative effects are not well known. It remains essential to develop an approach focused on the prevention and the study of contamination levels with one key word in mind: precaution. In this context and aiming to detect steroid hormones in tap water, surface water and wastewater at trace levels, new analytical methods have been developed within the framework of this project. The first method developed is based on high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS / MS). LC-MS/MS hyphenation involved using an electrospray ionization source at atmospheric pressure with heating element (H-ESI). Pre-concentration and purification of the samples were executed by on-line solid phase extraction (on-line SPE). The validated method presents several advantages: reproducibility, automation, minimum analysis time, reduced logistics and above all, detection limits ranging from 0.10 ng·L-1 to 7.5 ng·L-1 considering the different matrices studied. The second approach proposed herein is based on the development of an analysis method allowing lower detection limits compared to the previous workflow. The same detection method was used, but a modification was made to the sample extraction and purification. Allowing for greater pre-concentration than online SPE, manual SPE (off-line SPE) was used in this method. Depending on the particular matrix, the extraction step allowed to reach adequate detection limits for the analysis of environmental aqueous samples: 0.010 ng·L-1 up vi to 6.0 ng·L-1 from the matrix-free sample to the most complex matrices. The use of an automated system also made it possible to make the extraction step robust and reproducible. The analysis of the dissolved phase of water samples cannot be sufficient to understand and comprehensively assess the contamination of aquatic environments. The particulate phase in suspension in the water column (SPM) was also studied. The extraction method was optimized and validated. Coupled with the previous method of analysis, it was possible to quantify the steroid hormones attached to suspended materials. The obtained detection limits ranged from 0.10 ng/g to 3.0 ng/g dry weight. For each developed method, dissolved phase samples were analyzed for all the studied matrices (tap water, surface water and wastewater). Quantification of steroid hormones allowed the comprehension of concentration levels found in the environment under usual discharge conditions in multiples matrices. A seasonal study of a watercourse was also carried out during the winter, spring, summer and fall seasons to observe possible seasonal variations in terms of occurrence and concentration.
215

Développement et évaluation d’une méthode LC-MS/MS pour l’analyse de résidus de tir en criminalistique/Development and assessment of a LC-MS/MS method for the analysis of gunshot residues in criminalistics

Laza, Désiré 16 February 2007 (has links)
Ce travail de thèse rentre dans le cadre d’un projet de recherche appliquée mené à l’Institut National de Criminalistique et de Criminologie s’intitulant « développement d’un système intégral de détection et d’identification de résidus de tir » visant à doter le laboratoire de balistique chimique d’un outil performant pour la recherche et la caractérisation des résidus de tir aussi bien inorganiques qu’organiques. Comme nous l’expliquons dans le chapitre 1, l’analyse des résidus de tir est aujourd’hui essentiellement basée sur la mise en évidence par microscopie électronique à balayage des particules métalliques provenant de l’amorce. Cette pratique a des limites. Introductif, ce chapitre met en lumière la relation entre criminologie et criminalistique, donne un aperçu de la classification des armes et décrit les relations entre les armes de poing, les munitions, les résidus de tir et la criminalistique. La motivation de l’analyse de résidus organiques et plus particulièrement des stabilisants pour poudres propulsives y est aussi expliquée. Le but principal de ce travail étant le développement d’une méthode d’analyse des stabilisants par spectrométrie de masse en tandem couplée à la chromatographie liquide à haute performance (LC-MS/MS), ce premier chapitre aborde de façon détaillée le principe de fonctionnement d’un spectromètre de masse quadripolaire, qu’il soit avec simple quadripôle ou en tandem, et traite avec une attention particulière les aspects relatifs à la production d’ions, l’acquisition des données et la détection des ions. Le chapitre 2 est consacré aux résultats et discussions. Comme point de départ de tous les travaux ultérieurs, l’optimisation du fonctionnement du spectromètre et plus particulièrement la détermination des « ions précurseurs » et des « ions produits » y est traitée en détails. De plus, l’étude de la fragmentation des ions précurseurs y occupe une place prépondérante et conditionne l’établissement d’une méthode de détection et d’acquisition des données. Dans ce même chapitre sont successivement traités la mise au point de la méthode chromatographique pour l’analyse des stabilisants par LC-MS/MS, le couplage LC-MS/MS, la collecte et préparation des échantillons, dont l’extraction sur phase solide (SPE). Disposant des procédures de traitement des échantillons et d’une méthode LC-MS/MS, il nous a été possible de mener l’étude de faisabilité de l’analyse des stabilisants dans les échantillons prélevés sur les mains d’un tireur. Cette étude fait l’objet d’une proposition de publication jointe en annexe. Pour être exploitable en criminalistique, ce travail est complété par une étude sur les fréquences d’observation des stabilisants pour poudres propulsives sur les mains des non-tireurs. L’ensemble des résultats nous permet de dresser un bilan et proposer des perspectives décrites dans le chapitre 3. A cet égard, nous proposons de poursuivre les essais relatifs aux tests de persistance des résidus de stabilisant sur les mains des tireurs et d’entamer une étude sur la caractérisation des résidus de tir de la nitrocellulose. Du point de vue de l’exploitation des acquis de ce travail, nous suggérons que les méthodes et procédures développées soient mises à l’épreuve dans les affaires nécessitant l’analyse des prélèvements effectués sur les vêtements d’un suspect ou d’une victime. Cette mise à l’épreuve permettra de comparer l’efficacité de la méthode LC-MS/MS à celle de la technique SEM/EDX habituellement utilisée. Le chapitre 4 est consacré aux matériels et méthodes détaillant notamment les procédures de collectes et de traitement des échantillons, les paramètres de fonctionnement du spectromètre de masse et les méthodes analytiques. <br> <br> This thesis deals with a research project entitled "Development of an integral system of detection and identification of gunshot residues”, carried out at the Belgian National Institute of Criminalistics and Criminology (NICC). This project aims at providing the Laboratory of Chemical Ballistics, a powerful tool to detect and identify organic gunshot residues. For instance, the analyses of gunshot residues is presently performed mainly for characterizing metallic particles originating from the primer, using scanning electron microscopy coupled to energy dispersive X-ray microanalysis (SEM-EDX). However this technique has its limits and the goal of the thesis was the development of a method for the analysis of the stabilizers (and their derivatives) present in propellant powders with the use of tandem mass spectrometry coupled to high performance liquid chromatography (LC-MS/MS). The introduction highlights the relations between Criminology and Criminalistics; it gives an outline of the classification of weapons, and describes how handguns, ammunitions, gunshot residues and Criminalistics can be linked when investigating criminal cases. The motivation of the analysis of organic gunshot residues and in particular the propellant powder stabilizers is also explained. Chapter 1 deals in detail with the working principle of a quadrupole mass spectrometer, whether it is with a single quadrupole or composed of a tandem mass spectrometer. Important aspects connected with the ion production, the data acquisition and the ion detection are also considered. Chapter 2 presents the results and discussions. It begins with the optimization of the operating conditions of the spectrometer, and focuses more specifically on the determination of “precursor ions" and "daughter ions”. The study of the precursor ion is more important because it is required for the choice of parameters involved in the data acquisition mode. The development of a liquid chromatography (LC) method and the procedures for collecting and preparing the samples are explained. Moreover, Chapter 2 summarizes the results of a feasibility study of the analyses of stabilizers in samples collected from the hands of a shooter. This study was published in a peer reviewed journal [1]. A complementary study on the frequencies of observation of stabilizers on the hands of non-shooter persons is reported at the end the Chapter. The results allow also proposing perspectives which are described in Chapter 3. In this respect, the characterization of nitrocellulose residues and the study of the persistence of stabilizer residues on the hands of shooters should be undertaken. From the practical point of view, the developed methods and procedures should be tested in real cases which involve the analyses of the samples taken from the clothing of suspects and/or victims. These tests should allow an assessment of the LC-MS/MS method compared to the efficiency of the SEM/EDX technique currently used. Chapter 4 is dedicated to the materials and methods; the sample collection and treatment procedures, as well as the working parameters of the mass spectrometer and the analytical methods are explained in detail. [1]. Désiré Laza, Ph.D.; Bart Nys, Ph.D.; Jan De Kinder, Ph.D.; Andrée Kirsch - De Mesmaeker, Ph.D.; and Cécile Moucheron, Ph.D. Development of a Quantitative LC-MS/MS Method for the Analysis of Common Propellant Powder Stabilizers in Gunshot Residue. J. Forensic Sci, July 2007, Vol. 52, N° 4, 842-850.
216

Développement des méthodes bio analytique pour l’analyse quantitative et qualitative des peptides et protéines marqués par le couplage de la chromatographie et la spectrométrie de masse / Development of bio-analytical methods for the quantitative and qualitative analysis of labelled peptides and proteins via hyphenation of chromatography and mass spectrometry

Holste, Angela Sarah 24 February 2014 (has links)
Cette thèse est le résultat d’une cotutelle entre l'Université de Pau et des Pays de l'Adour (UPPA) à Pau, en France et l'Université Christian Albrecht (CAU) à Kiel, en Allemagne. Dans le cadre de cette collaboration internationale, des méthodes bio-analytiques sont développées pour analyser quantitativement et qualitativement des peptides et protéines marquées par le couplage de la chromatographie avec la spectrométrie de masse. Les peptides et les digestats des protéines sont marquées selon un protocole optimisé par des lanthanides en utilisant des composés à base de DOTA. La séparation des peptides est réalisée par IP-RP-nanoHPLC. Des données complémentaires sont acquises par MALDI-MS pour l'identification et par ICP-MS pour la quantification. Dans ce contexte, une étape de pré-nettoyage en ligne est développée et mise en œuvre dans le protocole de séparation par nanoHPLC. Cette étape permet l'élimination efficace des réactifs appliqués en excès et ainsi la diminution du bruit de fond lié à la présence de métaux lors des analyses par ICP-MS. Les données obtenues sont alors plus facile à interpréter, la sensibilité des signaux des peptides n’étant par ailleurs pas modifié. L'extraction en phase solide (SPE) appliquée comme alternative entraîne des pertes importantes de peptides et peut être considérée comme inadaptée pour l'analyse quantitative. Des additifs pour éluants de nanoHPLC, tels que l'EDTA et le HFBA sont testés et jugés non bénéfiques pour l'analyse des échantillons peptidiques normaux. HFBA peut être reconsidéré pour une application spéciale sur des peptides très hydrophiles. Des peptides marqués sont développés. Leur utilisation en quantité connue pourrait permettre la quantification rapide et simple d'un échantillon de digestat à faible complexité. De plus, cet ensemble de peptides permet la superposition fiable des chromatogrammes, et ainsi de comparer des données complémentaires obtenues par l’analyse d’échantillon par ICP-MS et MALDI-MS. Expériences d'application avec le couplage laser femtoseconde avec ICP-MS sont effectuées sur des plaques métalliques de MALDI MS et montrent des résultats très prometteurs. Pour cela, les échantillons préalablement identifiés par MALDI-MS sont analysés par fsLA-ICP-MS. Les premières tentatives de quantification sur la plaque en acier modifiée sont satisfaisantes et donnent des résultats répondant aux attentes. L’optimisation des paramètres de MALDI-MS facilite l’identification des peptides. / This PhD thesis was a Cotutelle between the Université de Pau et des Pays de l’Adour (UPPA) in Pau, France and the Christian-Albrechts University (CAU) in Kiel, Germany. In the course of this international collaboration, bio-analytical methods for the quantitative and qualitative analysis of labelled peptides and proteins were developed, which were based on the hyphenation of chromatography with mass spectrometry. Peptides and protein digests were lanthanide labelled using DOTA-based compounds according to an optimised protocol. Separation on the peptide level was performed using IP-RP-nanoHPLC. Complementary data sets were acquired using MALDI-MS for identification and ICP-MS for quantification. In this context, an online precleaning step was developed and implemented in the nanoHPLC separation routine, which allowed for effective removal of excess reagents. This lead to lowered metal backgrounds during ICP-MS measurements and thus better data interpretability, while guarding peptide recovery at a maximum level. An alternative offline purification using solid phase extraction (SPE) resulted in important peptide losses and can be considered unsuitable for quantitative analysis. Additives to the nanoHPLC eluents, such as HFBA and EDTA were tested and not deemed beneficial for the analysis of normal peptide samples. HFBA can be reconsidered for special application on very hydrophilic peptide species. A set of labelled peptides was developed, which due to application of known quantities could be employed for quick and simple quantification of a low complexity digest sample. In addition this peptide set allowed for the reliable superposition of chromatograms, enabling sample comparability especially for complementary ICP-MS and MALDI-MS data. Experiments for application of fsLA-ICP-MS on MALDI-MS target plates were conducted and showed very promising results. For this purpose, samples that were already identified using MALDI-MS were supposed to be remeasured using fsLA-ICP-MS. First quantification attempts on the modified steel target plate were successful and in the range of expectance. Adjusted parameters for MALDI-MS allowed for proper peptide identifications.
217

Développpement et évaluation d'une méthode LC-MS/MS pour l'analyse de résidus de tir en criminalistique / Development and assessment of a LC-MS/MS method for the analysis of gunshot residues in criminalistics

Laza, Désiré 16 February 2007 (has links)
Ce travail de thèse rentre dans le cadre d’un projet de recherche appliquée mené à l’Institut National de Criminalistique et de Criminologie s’intitulant « développement d’un système intégral de détection et d’identification de résidus de tir » visant à doter le laboratoire de balistique chimique d’un outil performant pour la recherche et la caractérisation des résidus de tir aussi bien inorganiques qu’organiques. Comme nous l’expliquons dans le chapitre 1, l’analyse des résidus de tir est aujourd’hui essentiellement basée sur la mise en évidence par microscopie électronique à balayage des particules métalliques provenant de l’amorce. Cette pratique a des limites. Introductif, ce chapitre met en lumière la relation entre criminologie et criminalistique, donne un aperçu de la classification des armes et décrit les relations entre les armes de poing, les munitions, les résidus de tir et la criminalistique. La motivation de l’analyse de résidus organiques et plus particulièrement des stabilisants pour poudres propulsives y est aussi expliquée. Le but principal de ce travail étant le développement d’une méthode d’analyse des stabilisants par spectrométrie de masse en tandem couplée à la chromatographie liquide à haute performance (LC-MS/MS), ce premier chapitre aborde de façon détaillée le principe de fonctionnement d’un spectromètre de masse quadripolaire, qu’il soit avec simple quadripôle ou en tandem, et traite avec une attention particulière les aspects relatifs à la production d’ions, l’acquisition des données et la détection des ions.<p>Le chapitre 2 est consacré aux résultats et discussions. Comme point de départ de tous les travaux ultérieurs, l’optimisation du fonctionnement du spectromètre et plus particulièrement la détermination des « ions précurseurs » et des « ions produits » y est traitée en détails. De plus, l’étude de la fragmentation des ions précurseurs y occupe une place prépondérante et conditionne l’établissement d’une méthode de détection et d’acquisition des données. Dans ce même chapitre sont successivement traités la mise au point de la méthode chromatographique pour l’analyse des stabilisants par LC-MS/MS, le couplage LC-MS/MS, la collecte et préparation des échantillons, dont l’extraction sur phase solide (SPE). Disposant des procédures de traitement des échantillons et d’une méthode LC-MS/MS, il nous a été possible de mener l’étude de faisabilité de l’analyse des stabilisants dans les échantillons prélevés sur les mains d’un tireur. Cette étude fait l’objet d’une proposition de publication jointe en annexe. Pour être exploitable en criminalistique, ce travail est complété par une étude sur les fréquences d’observation des stabilisants pour poudres propulsives sur les mains des non-tireurs.<p>L’ensemble des résultats nous permet de dresser un bilan et proposer des perspectives décrites dans le chapitre 3. A cet égard, nous proposons de poursuivre les essais relatifs aux tests de persistance des résidus de stabilisant sur les mains des tireurs et d’entamer une étude sur la caractérisation des résidus de tir de la nitrocellulose. Du point de vue de l’exploitation des acquis de ce travail, nous suggérons que les méthodes et procédures développées soient mises à l’épreuve dans les affaires nécessitant l’analyse des prélèvements effectués sur les vêtements d’un suspect ou d’une victime. Cette mise à l’épreuve permettra de comparer l’efficacité de la méthode LC-MS/MS à celle de la technique SEM/EDX habituellement utilisée. <p>Le chapitre 4 est consacré aux matériels et méthodes détaillant notamment les procédures de collectes et de traitement des échantillons, les paramètres de fonctionnement du spectromètre de masse et les méthodes analytiques.<p><p><br><p><br><p><p>This thesis deals with a research project entitled "Development of an integral system of detection and identification of gunshot residues”, carried out at the Belgian National Institute of Criminalistics and Criminology (NICC). This project aims at providing the Laboratory of Chemical Ballistics, a powerful tool to detect and identify organic gunshot residues. For instance, the analyses of gunshot residues is presently performed mainly for characterizing metallic particles originating from the primer, using scanning electron microscopy coupled to energy dispersive X-ray microanalysis (SEM-EDX). However this technique has its limits and the goal of the thesis was the development of a method for the analysis of the stabilizers (and their derivatives) present in propellant powders with the use of tandem mass spectrometry coupled to high performance liquid chromatography (LC-MS/MS).<p>The introduction highlights the relations between Criminology and Criminalistics; it gives an outline of the classification of weapons, and describes how handguns, ammunitions, gunshot residues and Criminalistics can be linked when investigating criminal cases. The motivation of the analysis of organic gunshot residues and in particular the propellant powder stabilizers is also explained.<p>Chapter 1 deals in detail with the working principle of a quadrupole mass spectrometer, whether it is with a single quadrupole or composed of a tandem mass spectrometer. Important aspects connected with the ion production, the data acquisition and the ion detection are also considered.<p>Chapter 2 presents the results and discussions. It begins with the optimization of the operating conditions of the spectrometer, and focuses more specifically on the determination of “precursor ions" and "daughter ions”. The study of the precursor ion is more important because it is required for the choice of parameters involved in the data acquisition mode. The development of a liquid chromatography (LC) method and the procedures for collecting and preparing the samples are explained. Moreover, Chapter 2 summarizes the results of a feasibility study of the analyses of stabilizers in samples collected from the hands of a shooter. This study was published in a peer reviewed journal [1]. A complementary study on the frequencies of observation of stabilizers on the hands of non-shooter persons is reported at the end the Chapter.<p>The results allow also proposing perspectives which are described in Chapter 3. In this respect, the characterization of nitrocellulose residues and the study of the persistence of stabilizer residues on the hands of shooters should be undertaken. From the practical point of view, the developed methods and procedures should be tested in real cases which involve the analyses of the samples taken from the clothing of suspects and/or victims. These tests should allow an assessment of the LC-MS/MS method compared to the efficiency of the SEM/EDX technique currently used.<p>Chapter 4 is dedicated to the materials and methods; the sample collection and treatment procedures, as well as the working parameters of the mass spectrometer and the analytical methods are explained in detail. <p>[1]. Désiré Laza, Ph.D. Bart Nys, Ph.D. Jan De Kinder, Ph.D. Andrée Kirsch - De Mesmaeker, Ph.D. and Cécile Moucheron, Ph.D. Development of a Quantitative LC-MS/MS Method for the Analysis of Common Propellant Powder Stabilizers in Gunshot Residue. J. Forensic Sci, July 2007, Vol. 52, N° 4, 842-850.<p> / Doctorat en Sciences / info:eu-repo/semantics/nonPublished

Page generated in 0.0727 seconds