• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 126
  • 98
  • 16
  • 15
  • 14
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 334
  • 91
  • 67
  • 67
  • 41
  • 40
  • 38
  • 35
  • 34
  • 34
  • 33
  • 31
  • 29
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

O uso da hiperinsuflação com o ventilador mecânico como técnica de higiene brônquica

Naue, Wagner da Silva January 2015 (has links)
Base teórica: Muitos pacientes internados em Unidade de Terapia Intensiva (UTI) necessitam da instituição da ventilação mecânica invasiva (VM). Porém esta pode trazer efeitos deletérios como: alteração na higiene brônquica e pneumonia associada à ventilação mecânica (PAV). Devido a isso, faz-se necessária avaliação de técnicas de higiene brônquicas eficazes e o menos deletérias possíveis. Objetivos: Comparar a eficácia das técnicas em estudo: vibrocompressão (VB) (G1), hiperinsuflação com o ventilador mecânico (HMV) (G2) VB + HMV (G3) na quantidade de secreção aspirada (SEC), no tempo de VM, na incidência de PAV, na reintubação orotraqueal (Re-IoT) e na mortalidade de pacientes em VM. Método: Ensaio clínico randomizado, realizado no Centro de Terapia Intensiva do Hospital de Clínicas de Porto Alegre (HCPA). Foram incluídos no estudo 93 pacientes (29 G1, 32 G2 e 32 G3) em VM por mais de 24 horas. Foram aplicadas as seguintes técnicas: aspiração isolada (ASP), VB, HMV e VB + HMV. Foram medidas as seguintes variáveis: frequência cardíaca (FC), frequência respiratória (FR), pressão arterial média (PAM), saturação arterial periférica de oxigênio (SpO2), pressão inspiratória de pico (PIP), volume corrente (VC), complacência dinâmica (Cdyn), peso da SEC; tempo de VM, Re-IoT, incidência de PAV e mortalidade na VM. Conclusão: O grupo 3 foi o único que apresentou aumento significativo da SEC, quando comparado à ASP (0,7 g (0,1-2,5) vs 0,2 g (0,0-0,6) – p = 0,006). Em comparação com os demais grupos, o grupo 2 apresentou aumento significativo na incidência de PAV (22% - p = 0,003) e Re-IoT (21,9% - p = 0,048), demonstrando assim, na amostra estudada, que VB + HMV é mais eficaz quanto à quantidade de SEC e exerce efeito protetor, juntamente com a VB, na incidência de PAV e Re-IoT. / Background: Many patients admitted to the Intensive Care Unit (ICU) require the institution of invasive Mechanical Ventilation (MV). However, this can bring harmful effects such as changes in mucociliary transport and cough capacity, leading to bronchial obstruction and Ventilator Associated-Pneumonia (VAP). Objective: To compare the efficacy of the techniques: Vibrocompression (G1), Hyperinflation with Mechanical Ventilation (G2) Vibrocompression + Hyperinflation with Mechanical Ventilation (G3) in the amount of Aspirated Secretions (AS), MV time, the incidence of VAP, Re-intubation tracheal (Re-IoT) and mortality of patients on MV. Method: Randomized clinical trial, conducted at the Intensive Care Unit, of the Hospital de Clinicas de Porto Alegre (HCPA). 93 patients were included in the study (29 G1, 32 G2 and 32 G3) in mechanical ventilation for more than 24 hours. The following techniques were applied: Isolated Aspiration (ASP), Vibrocompression (VB), Hyperinflation with Mechanical Ventilation (HMV) Vibrocompression + Hyperinflation with Mechanical Ventilation (HMV + VB). The following variables were measured: Heart Rate (HR), Respiratory Rate (RR), Mean Arterial Pressure (MAP), Peripheral Arterial Oxygen Saturation (SpO2); Peak Inspiratory Pressure (PIP), Tidal Volume (TV); Dynamic Compliance (Cdyn); weight of the AS; VM time; Re-IoT; VAP incidence and mortality in the VM. Conclusion: The HMV + VB (G3) was the only group that showed significant increase in the AS (0.7 g (0.1-2.5) vs 0.2 g (0.0-0.6) – p = 0.006) when compared to ASP. Compared with the other groups G2 showed a significant increase in the incidence of VAP (22% - p = 0.003) and Re-IoT (21.9% - p = 0.048). Thus demonstrating in the sample, which HMV + VB is more effective as the amount of secretion aspirated and has a protective effect, along with the VB, the incidence of VAP and Re-IoT.
202

Análise quantitativa das partículas de óxido de alumínio geradas na abrasão a ar em consultório odontológico

Scannavino, Fábio Luiz Ferreira [UNESP] 18 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-18Bitstream added on 2014-06-13T20:56:50Z : No. of bitstreams: 1 scannavino_flf_me_arafo.pdf: 459200 bytes, checksum: 7da03a73587b35e389935c5420bccdb6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O sistema de abrasão a ar funciona por meio de energia cinética produzida por um jato pressurizado de partículas de óxido de alumínio, que tem a finalidade de abrasionar a superfície dentária. O objetivo deste estudo foi avaliar a efetividade do sistema de sucção, disponível em consultório odontológico, na captação das partículas de óxido de alumínio emitidas pelo aparelho de abrasão a ar. Um dispositivo metálico, que reproduzia as posições e as distâncias de trabalho do cirurgião-dentista, foi elaborado para a deposição das partículas de óxido de alumínio presentes no campo operatório durante a utilização do sistema de abrasão a ar. Para a aspiração do pó de óxido de alumínio foram empregadas as sucções de alta potência e odontológica convencional com sugadores convencional e modificado por funil. A quantificação das partículas foi obtida pela massa de óxido de alumínio depositada após a aplicação do aparelho de abrasão a ar. Os resultados obtidos pela estatística descritiva gráfica revelaram que a maior deposição das partículas ocorreu a 20 cm do centro da cavidade bucal e na posição de trabalho 9 horas, quando se utilizou o sugador convencional em alta potência de sucção. / The air abrasion system works using kinetic energy produced by pressurized air with aluminum oxide particles resulting in abrasion of the dental surface. The aim of this study was to compare the efficacy of high-volume evacuation (HVE) and conventional dental suction (CDS) in aluminum oxide particles evacuation. A metallic device was elaborated to reproduce the dentist operatory positions and to aluminum oxide particles deposition. The dust collection was made by conventional saliva ejector and modified ejector by funnel-shaped. The amount of particles showed that the greatest abrasive particles deposition occurred at the 20cm of distance from the center of the mouth at 9 o'clock operatory position with the conventional saliva ejector attached to high-volume evacuation (HVE).
203

O uso da hiperinsuflação com o ventilador mecânico como técnica de higiene brônquica

Naue, Wagner da Silva January 2015 (has links)
Base teórica: Muitos pacientes internados em Unidade de Terapia Intensiva (UTI) necessitam da instituição da ventilação mecânica invasiva (VM). Porém esta pode trazer efeitos deletérios como: alteração na higiene brônquica e pneumonia associada à ventilação mecânica (PAV). Devido a isso, faz-se necessária avaliação de técnicas de higiene brônquicas eficazes e o menos deletérias possíveis. Objetivos: Comparar a eficácia das técnicas em estudo: vibrocompressão (VB) (G1), hiperinsuflação com o ventilador mecânico (HMV) (G2) VB + HMV (G3) na quantidade de secreção aspirada (SEC), no tempo de VM, na incidência de PAV, na reintubação orotraqueal (Re-IoT) e na mortalidade de pacientes em VM. Método: Ensaio clínico randomizado, realizado no Centro de Terapia Intensiva do Hospital de Clínicas de Porto Alegre (HCPA). Foram incluídos no estudo 93 pacientes (29 G1, 32 G2 e 32 G3) em VM por mais de 24 horas. Foram aplicadas as seguintes técnicas: aspiração isolada (ASP), VB, HMV e VB + HMV. Foram medidas as seguintes variáveis: frequência cardíaca (FC), frequência respiratória (FR), pressão arterial média (PAM), saturação arterial periférica de oxigênio (SpO2), pressão inspiratória de pico (PIP), volume corrente (VC), complacência dinâmica (Cdyn), peso da SEC; tempo de VM, Re-IoT, incidência de PAV e mortalidade na VM. Conclusão: O grupo 3 foi o único que apresentou aumento significativo da SEC, quando comparado à ASP (0,7 g (0,1-2,5) vs 0,2 g (0,0-0,6) – p = 0,006). Em comparação com os demais grupos, o grupo 2 apresentou aumento significativo na incidência de PAV (22% - p = 0,003) e Re-IoT (21,9% - p = 0,048), demonstrando assim, na amostra estudada, que VB + HMV é mais eficaz quanto à quantidade de SEC e exerce efeito protetor, juntamente com a VB, na incidência de PAV e Re-IoT. / Background: Many patients admitted to the Intensive Care Unit (ICU) require the institution of invasive Mechanical Ventilation (MV). However, this can bring harmful effects such as changes in mucociliary transport and cough capacity, leading to bronchial obstruction and Ventilator Associated-Pneumonia (VAP). Objective: To compare the efficacy of the techniques: Vibrocompression (G1), Hyperinflation with Mechanical Ventilation (G2) Vibrocompression + Hyperinflation with Mechanical Ventilation (G3) in the amount of Aspirated Secretions (AS), MV time, the incidence of VAP, Re-intubation tracheal (Re-IoT) and mortality of patients on MV. Method: Randomized clinical trial, conducted at the Intensive Care Unit, of the Hospital de Clinicas de Porto Alegre (HCPA). 93 patients were included in the study (29 G1, 32 G2 and 32 G3) in mechanical ventilation for more than 24 hours. The following techniques were applied: Isolated Aspiration (ASP), Vibrocompression (VB), Hyperinflation with Mechanical Ventilation (HMV) Vibrocompression + Hyperinflation with Mechanical Ventilation (HMV + VB). The following variables were measured: Heart Rate (HR), Respiratory Rate (RR), Mean Arterial Pressure (MAP), Peripheral Arterial Oxygen Saturation (SpO2); Peak Inspiratory Pressure (PIP), Tidal Volume (TV); Dynamic Compliance (Cdyn); weight of the AS; VM time; Re-IoT; VAP incidence and mortality in the VM. Conclusion: The HMV + VB (G3) was the only group that showed significant increase in the AS (0.7 g (0.1-2.5) vs 0.2 g (0.0-0.6) – p = 0.006) when compared to ASP. Compared with the other groups G2 showed a significant increase in the incidence of VAP (22% - p = 0.003) and Re-IoT (21.9% - p = 0.048). Thus demonstrating in the sample, which HMV + VB is more effective as the amount of secretion aspirated and has a protective effect, along with the VB, the incidence of VAP and Re-IoT.
204

Hydrodynamic Study of a Suction Stabilized Float (SSF)

January 2014 (has links)
abstract: In this work, the hydrodynamics of Suction Stabilization is studied. Suction stabilization was found to stabilize floating platforms/floats in a much better way as compared to the conventional methods. This was achieved by an effective increment in the metacentric height due to the Inverse Slack Tank (IST) effect. The study involves the analysis of the existing designs and optimizing its performance. This research investigates the stability of such floats and the hydrodynamic forces acting on the same for offshore applications, such as wind turbines. A simple mathematical model for the condition of parametric resonance is developed and the results are verified, both analytically and experimentally. / Dissertation/Thesis / Real time working of SSF in heavy wind and rain conditions / Animation explaining working of SSF / Experiment with patio umbrella mounted on SSF / Masters Thesis Mechanical Engineering 2014
205

Análise de ruptura de talude em solo não saturado / Slope back analysis in unsatured soils

José Antonio Cancino Calle 30 June 2000 (has links)
Apresenta-se neste trabalho uma análise de ruptura de um talude em solo não saturado. O talude, com cerca de 15 m de altura, é composto de areia fina a média argilosa, com grau de saturação da ordem de 55% e SPT variando entre 4 golpes no topo a 13 golpes na base. Determinaram-se as seguintes propriedades do solo: resistência, condutividade hidráulica saturada e não saturada e curva de retenção, além de medir-se a sucção matricial em campo ao longo do ano. Efetuaram-se análises paramétricas para avaliar o efeito da precipitação na mudança do perfil de sucção matricial do terreno e suas implicações na resistência e, por extensão, na estabilidade do talude. Construíram-se, também, ábacos que incluem o efeito da variação da sucção matricial, utilizáveis para taludes com características semelhantes ao talude estudado. Verificou-se que para as condições do talude natural, no auge da estação seca, as sucções matriciais são de tal magnitude que fornecem estabilidade ao talude. À medida que ocorrem precipitações, as sucções matriciais reduzem-se e o fator de segurança do talude diminui, o que justifica a ruptura ocorrida. / In this article is showing an slope back analysis in unsaturated soil. The slope, with about 15 m of height, it is composed of a fine to medium clayey sand, with degree of saturation of the order of 55% and SPT varying among 4 blows in the top to 13 blows in the base. The following properties of the soil were determined: resistance, saturated and unsaturated conductivity and it curves of retention, besides measuring the suction along the year. Parametric analyses were made to evaluate the effect of the precipitation in the changes of the ground matricial suction profile and its implications in the resistance and, by extension, in the slope stability. They were also made, some abaci that include the effect of the matricial suction variation, usable for slopes with similar characteristics to the studied slope. It was verified that for the conditions of the natural slope, next to the peak of the dry station, the matricial suction is of such magnitude that it supply stability to the slope. In the successive events of precipitations the matricials suctions is reduced and the slope security factor decreases, that justifies the happened rupture.
206

Aspiração endotraqueal em pacientes críticos adultos intubados sob ventilação mecânica: revisão sistemática / Endotracheal suction in intubated critically ill adult patients with mechanical ventilation: systematic review

Débora Oliveira Favretto 02 September 2011 (has links)
Este estudo trata-se de uma revisão sistemática da literatura e tem como referencial teórico a prática baseada em evidência. Buscou-se identificar e analisar na literatura evidências oriundas de ensaios clínicos controlados e randomizados sobre os cuidados relacionados à aspiração de secreções endotraqueais em pacientes adultos, em estado crítico, intubados e sob ventilação mecânica. Os passos metodológicos desta revisão foram guiados pelas recomendações da Colaboração Cochrane. A busca foi realizada nas bases de dados PUBMED, EMBASE, CENTRAL, CINAHL e LILACS. Das 631 referências encontradas, 17 estudos foram selecionados após a análise dos títulos e resumos. Foi realizada a extração dos dados e análise do risco de viés por dois revisores, para cada estudo selecionado. Os 17 estudos foram publicados no período de 1987 à 2009. Ao todo, foram investigados 2.890 pacientes adultos, intubados e sob ventilação mecânica. Foram encontradas evidências quanto a seis categorias de intervenções relacionadas à aspiração endotraqueal: aspiração endotraqueal baseada em pesquisa x aspiração endotraqueal usual, em um estudo; aspiração endotraqueal de rotina x aspiração endotraqueal minimamente invasiva, em dois estudos; aspiração endotraqueal de sistema aberto x aspiração endotraqueal de sistema fechado, em oito estudos; troca do sistema fechado em 24 horas x 48 horas, em dois estudos; troca diária do sistema fechado x troca não rotineira, em um estudo; e instilação de soro fisiológico x não instilação de soro fisiológico, em três estudos. As intervenções foram realizadas analisando desfechos referentes a alterações hemodinâmicas, alterações dos gases sanguíneos, colonização microbiana e infecção nosocomial, e outros desfechos. Foram encontradas evidências relevantes quanto à prática da aspiração endotraqueal, entretanto, as limitações metodológicas e riscos de viés encontrados nos estudos selecionados reduzem a confiabilidade de tais evidências, demonstrando a necessidade de estudos futuros. Também, foi observada a necessidade da realização de ECCRs que contemplem os demais passos da aspiração endotraqueal e desfechos. / This systematic review of literature used the evidence-based practice as the theoretical framework. This study aimed to identify and analyze in the literature the evidence of randomized controlled trials on care related to the endotracheal secretions suctioning in critically ill adult patients who were intubated and undergoing mechanical ventilation. The methodological steps were guided by the recommendations of the Cochrane Collaboration. The search was conducted in the PUBMED, EMBASE, CENTRAL, CINAHL and LILACS databases. Of the 631 found references, 17 studies were selected after the analysis of titles and abstracts. The data extraction and the analysis of the risk of bias by two reviewers for each selected study were performed. The 17 studies were published in the period from 1987 to 2009. In the total, 2,890 adult patients who were intubated and undergoing mechanical ventilation were investigated. Evidences for six categories of interventions related to endotracheal suction were found: research-based endotracheal suction x usual endotracheal suction, in one study; routine endotracheal suction x minimally invasive endotracheal suction, in two studies; open endotracheal suction system x closed endotracheal suction system, in eight studies; change of closed system in 24 hours x 48 hours, in two studies; daily change of closed system x non-routine change, in one study; and instillation of saline x non-instillation of saline, in three studies. The interventions were performed through the analysis of outcomes related to hemodynamic alterations, blood gas alterations, microbial colonization and nosocomial infection, and other outcomes. Relevant evidences related to the practice of endotracheal suction were found; however, methodological limitations and risks of bias found in selected studies reduce the reliability of such evidences, demonstrating the need for further studies. Also, the need for the realization of ECCRs that address the remaining steps of endotracheal suction and outcomes were observed.
207

Retroanálise de escorregamentos em solos residuais não saturados / Back analysis the landslides in residual soils unsaturated

Alexandre Cerqueira de Jesus 29 August 2008 (has links)
Foram estudados cinco casos históricos de escorregamentos ocorridos na cidade de Salvador - Bahia, através do levantamento e tratamento dos dados preexistentes. Também foram realizados ensaios complementares através da instrumentação em campo com tensiômetros e ensaios de laboratório. A retroanálise, objetivo central desse trabalho foi realizada a partir das geometrias de cada uma das encostas, antes e após a ruptura resultando na definição dos possíveis parâmetros médios de resistência ao cisalhamento. Secundariamente foram realizadas análises de estabilidade convencional para a avaliação dos fatores de segurança de cada encosta, com os parâmetros de resistência na condição não saturada e saturada. Por fim foram efetuadas simulações numéricas que visavam reproduzir as condições que levaram à ruptura da encosta do Alto do Bom Viver, baseado nos conceitos da mecânica dos solos não saturados. Os resultados mostram que a maioria dos escorregamentos estudados, ocorre no horizonte do solo residual maduro, onde o valor de ângulo de atrito médio é 34º, condizente com as superfícies de rupturas pouco profundas observadas em campo. As análises paramétricas sugerem que o mecanismo de ruptura mais provável esteja relacionado à diminuição da coesão aparente do solo em virtude da diminuição da sucção. / Five historical cases of landslides in the city of Salvador, Bahia, were studied through the survey and treatment of the preexistent data. Complementary experiments were accomplished through the instrumentation field using tensiometers and laboratory testing. The back-analysis, main objective of this research, was accomplished through the geometries of each slope, before and after the rupture, resulting in the definition of the possible medium parameters of resistance to shear. Secondary, analysis of the conventional stability to the evaluation of safety factors of each slope was accomplished, with the parameters of resistance in the unsaturated and saturated condition. At last, numerical simulations were done, aiming at reproducing the conditions which led to the rupture of the slope of Alto do Bom Viver, based on the concepts of mechanics of non saturated soil. The results demonstrated that the majority of the slips studied occur in the horizon of the mature residual soil, where the value of the angle of the medium attrition is of 34 degrees, suitable with the surface of little deep ruptures observed in the field. The parametric analysis suggests that the most probable mechanism of rupture is related to the decrease of the apparent cohesion of the soil due to the decrease of suction.
208

Resistência ao cisalhamento de um solo não saturado com medida direta de sucção / Shear strength of an unsaturated soil with direct measurement of suction

Osvaldo de Freitas Neto 08 July 2008 (has links)
Este trabalho teve como objetivo utilizar um tensiômetro de alta capacidade (TAC) para realizar medidas diretas de sucção em ensaios de resistência ao cisalhamento de um solo compactado. Foram realizados ensaios de resistência à compressão triaxial do tipo consolidado drenado na condição saturada, ensaios consolidados não drenados na condição não saturada e ensaios de resistência à compressão simples. Os ensaios de compressão simples foram realizados em uma série de repetibilidade e outras duas para a verificação da influência da sucção na resistência de um solo compactado, fazendo-se variar a massa específica aparente seca do solo e o teor de umidade. Em todos os ensaios de compressão simples o TAC registrou aumento da sucção até cerca de 3% de deformação axial, quando a partir daí a sucção tendeu a estabilização. Os valores de resistência à compressão simples e de sucção tenderam a crescer com o aumento da massa específica aparente seca do solo e com a redução do teor de umidade. A resistência foi correlacionada com a sucção e com a massa específica aparente seca para os ensaios com teor de umidade constante e com a sucção e o teor de umidade para os ensaios com massa específica aparente seca constante. Os ângulos \'fi\'b que relacionam o aumento da resistência com a sucção variaram dependendo da forma de determinação e foram maiores quando determinados diretamente a partir da resistência não drenada do que quando determinados a partir da proposta de Fredlund et al. (1978). / The purpose this study was to measure the suction with high capacity tensiometer (HCT), placed at the bottom of the sample, during shear strength tests on a compacted soil. Three kinds of shear strength tests were performed on the sample in different conditions of saturation: triaxial consolidated drained in saturated condition, triaxial consolidated undrained with constant water content and unconfined compression in unsaturated condition. To assess the development of the suction and its influence on the shear strength of a compacted soil, the unconfined compression tests were performed in a series of repeatability and the others with variation of the dry density and water content of the sample. In all unconfined compression tests, the HCT recorded increase of suction until 3% axial deformation, approximately, from where the suction tended to stabilized. The values of compressive strength and suction increased with higher dry densities and lower water contents. Firstly, the shear strength was correlated with suction and the dry density, for constant water content tests. In sequence, it was correlated with suction and the water content for constant dry density tests. The \'fi\'b angle, that relates the increase of the strength with suction, varied depending of determination method. Its values were higher when directly determined from the undrained strength than when determined from the model presented by Fredlund et al. (1978).
209

Colapsibilidade com sucção controlada de um solo coluvionar e laterítico de Campinas/SP / Collapsibility with controlled suction of a colluvial and lateritic soil from Campinas/SP

Benatti, Julio César Beltrame 16 August 2018 (has links)
Orientador: Miriam Gonçalves Miguel / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-16T04:14:39Z (GMT). No. of bitstreams: 1 Benatti_JulioCesarBeltrame_M.pdf: 6264019 bytes, checksum: d8acbf7fa717ecad7f6fcafdfda4bb3b (MD5) Previous issue date: 2010 / Resumo: Este trabalho tem como objetivo geral estudar a colapsibilidade de um solo coluvionar e laterítico, através da realização de ensaios edométricos com controle de sucção, executados em laboratório, e da interpretação de lâminas delgadas e impregnadas com o solo antes e depois dos ensaios, de modo a se levar em conta as diferenças das estruturas naturais e após o colapso. As amostras de solo indeformadas, submetidas aos ensaios, foram coletadas através da abertura de um poço de inspeção no Campo Experimental de Mecânica dos Solos e Fundações da UNICAMP - CEMSF, cujo perfil geotécnico apresenta uma camada de solo superficial de origem coluvionar, constituída de uma argila siltosa, porosa, em condição não saturada, laterítica e de espessura em torno de 6,5m. As amostras foram caracterizadas por meio de ensaios geotécnicos padronizados, por ensaios químico-mineralógicos e de porosimetria por intrusão de mercúrio. Os ensaios edométricos com controle de sucção foram realizados para amostras retiradas das profundidades 1,5m; 4,5m e 6,5m, e os valores de sucção matricial impostos foram 0kPa, 50kPa, 100kPa, 200kPa e 400kPa. Os ensaios edométricos mostraram que o solo é colapsível para praticamente todos os valores de carregamentos e de sucções ensaiados. Encontraram-se valores de Potencial de Colapso da ordem de 12% para a amostra da profundidade 1,5m. A partir dos resultados experimentais, fez-se a calibração de modelos elasto-plásticos propostos na literatura técnico-científica. Verificou-se que para cada profundidade ensaiada houve um modelo que mais se ajustou. Propuseram-se, a partir dos resultados obtidos, modelos estruturais para o colapso do solo. Verificou-se uma diferença de comportamento para cada uma das profundidades ensaiadas, sendo o comportamento da amostra da profundidade 1,5m influenciado basicamente por forças de sucção, o da amostra da profundidade 4,5m regido pela presença de agente cimentante, e a da profundidade 6,5m influenciado pela presença de grãos de quartzo mais angulosos / Abstract: This study aims at investigating the collapsibility of coluvionar and lateritic soil by oedometer tests with controlled suction, performed in the laboratory, and by the interpretation of the soilimpregnated thin plates before and after the tests, so as to take into account the differences between natural and "after collapse" structures. The undisturbed soil samples submitted for testing were extracted from the pit shaft opened in the Foundation and Mechanics Soil Experimental Field of the State University of Campinas - Unicamp whose geotechnical profile shows a superficial layer of coluvionar origin, consisting of a porous, unsaturated and lateritic silty clay with an approximate thickness of 6.5m. The samples were characterized by geotechnical tests, through chemical and mineralogical tests and porosimetry tests. The oedometric tests with controlled suction were performed for samples from 1.5m, 4.5m and 6.5m depths, and the matric suction path values were 0kPa, 50kPa, 100kPa, 200kPa and 400kPa. Collapse Index values, about 12%, were found in the more superficial sample. The calibration of elastoplastic models, proposed by technical and scientific literatures, was carried out, based on the experimental results. Model, which best fitted each sample, was found. Structural models were proposed for the collapse of the samples and differences in the behavior for each of the samples were observed. The behavior of sample depth of 1.5m was influenced primarily by suction forces; the sample behavior at 4.5m depth was controlled by the presence of cementing agent, and for the sample at 6.5m depth, the behavior was characterized by the presence of more angular quartz grains / Mestrado / Geotecnia / Mestre em Engenharia Civil
210

Análise do comportamento mecânico de um solo expansivo da província petrolífera de Urucu-AM para fins de pavimentação / Analysis of mechanical behavior of an expansive soil from the oil province of Urucu-AM for paving

SOUZA, Leonardo Sebastiao de 30 October 2009 (has links)
Made available in DSpace on 2014-07-29T15:18:18Z (GMT). No. of bitstreams: 1 0-CAPA 1.pdf: 300598 bytes, checksum: 0e9449ac9ab29b32b36cc8276ea57604 (MD5) Previous issue date: 2009-10-30 / The establishment of transportation infrastructure is critical to the development of the Urucu- AM region, a newly developed oil exploration area in the Amazonas state. The construction of such infrastructure is challenging due to the lack of suitable materials for the construction pavement base and subbase courses and adverse weather conditions, with alternating heavy rainfall and drought periods. Besides the shortage of suitable granular material, the presence of expansive soils is often verified. The presence of expansive soils associated with inadequate moisture content during compaction, results in the occurrence of cracks in the pavements, drastically reducing its performance and lifetime. A quantitative understanding of this type of problem requires the analysis of the interaction between the unsaturated soil surface and the atmosphere and the study the mechanical behavior (stress-strain) of unsaturated soil. Such understanding requires the determination of the variations in soil moisture and total volume. The quantification of tensile stresses also requires the establishment or evaluation of the constitutive relations of the unsaturated expansive soils involved. Experiments were conducted in the laboratory with the objective of characterizing the hydraulic and mechanical behavior of expansive soils from Urucu-AM. Chemical, physical and mineralogy characterization tests were carried out for the soil. Geotechnical characterization and Proctor compaction tests and compression were performed. To study the soil in the unsaturated condition, the main focus of this work, tests were performed using the filter paper technique and the axis translation technique under oedometric conditions. For the suction controlled oedometric tests, a cell developed specially for this purpose was employed. The oedometer allows for the independent control of vertical stress and matric suction and the monitoring of the variation of moisture and total volume study. State surfaces for void ratio, degree of saturation and gravimetric moisture content were determined. The results obtained show the expected mechanical behavior of the soil under wetting paths. / O estabelecimento de uma infra-estrutura de transporte é fundamental para o desenvolvimento da região denominada de província petrolífera de Urucu-AM. A construção desta infraestrutura esbarra em varias dificuldades entre elas a escassez de materiais adequados para a construção de bases e sub-bases de pavimentos e as condições climáticas adversas, com alternância de períodos de alta pluviosidade e períodos de estiagem. Além da escassez de material granular adequado, observa-se com freqüência a presença de solos argilosos expansivos. A presença de tais solos, associada às condições freqüentemente inadequadas de umidade de compactação, resulta na ocorrência de trincas nos pavimentos, reduzindo drasticamente o seu desempenho e vida útil. Um entendimento quantitativo do problema requer a análise da interação entre o solo não saturado de superfície e a atmosfera e o estudo do comportamento mecânico (tensão-deformação) do solo não saturado. Tal entendimento passa pela determinação das variações de umidade do solo e sua variação volumétrica total. A quantificação das tensões de tração requer também o estabelecimento ou avaliação de relações constitutivas dos solos expansivos não saturados envolvidos. Foram conduzidos experimentos em laboratório com o objetivo de caracterizar o comportamento hidráulico e mecânico de solos expansivos de Urucu-AM. Inicialmente foram realizadas análises químicas, caracterização física e determinação da mineralogia, para caracterização das macro e microestruturas dos solos estudados. Foram executados também ensaios de caracterização geotécnica e compactação Proctor. Para o estudo do solo na condição não saturado, principal enfoque desta dissertação, foram realizados ensaios de papel filtro e de adensamento com controle de sucção. Para o ensaio de adensamento com controle de sucção foi utilizada uma prensa oedométrica especialmente desenvolvida para este fim. Como esta prensa foi possível aplicar de forma independente tensões verticais, sucção matricial e monitorar a variação de umidade e de volume do solo em estudo. As superfícies de estado de índice de vazios, grau de saturação de umidade do solo foram determinadas. Os resultados obtidos permitiram a determinação do comportamento do solo compactado durante trajetórias de molhagem.

Page generated in 0.0462 seconds