• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 1
  • Tagged with
  • 34
  • 34
  • 34
  • 9
  • 9
  • 9
  • 9
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

[en] DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES / [pt] DESENVOLVIMENTO DE MÉTODOS BASEADOS NA ELETROFORESE CAPILAR COM DIFERENTES ABORDAGENS DE DETECÇÃO PARA DETERMINAÇÃO DE ORGANOESTANHOS, ESTROBILURINAS E AMINOGLICOSÍDEOS

CABRINI FERRAZ DE SOUZA 02 July 2014 (has links)
[pt] Neste trabalho, métodos baseados em diferentes abordagens em eletroforese capilar (CE) foram propostos. No caso da determinação de compostos organoestanhos ou OTs (difenilestanho e monofenilestanho) em fluidos biológicos, foi usada abordagem de eletroforese capilar por zona (CZE) hifenada com a espectrometria de massas (do tipo quadrupolo) com fonte de plasma indutivamente acoplado (CE-ICP-MS). As condições de análise foram estudadas no modo univariado visando otimizar a composição da solução eletrolítica (tampão acetato 5,0 mmol L(-1), pH 2,8) e obter os parâmetros instrumentais (45 graus Celsius, mais 30 kV e 30 s de tempo de introdução hidrodinâmica de amostra). A solução de complementação foi uma solução aquosa 5,0 mmol L(-1) de NH4NO3 contendo 10 por cento metanol em volume e 1,0 Mg L(-1) de Cspositivo, com pH ajustado para 2,8 com tampão acetato. A vazão dessa solução foi mantida em 40 ML min(-1). Os OTs foram diluídos em solução de metanol:tampão acetato de sódio 50:50 por cento v/v ou apenas em tampão acetato de sódio pH 2,8. As condições de detecção do ICP-MS foram ajustadas em 1200 W, 15 L min(-1) de vazão de argônio para formação do plasma, 1 L min(-1) de vazão de argônio auxiliar. A vazão de argônio do nebulizador foi ajustada diariamente. Os isótopos de estanho 120Sn e 118Sn foram monitorados, assim como o 133Cspositivo para controlar a eficiência e estabilidade do processo de nebulização. A resposta linear do método ficou entre 0,050 a 2,0 mg L(-1) de Sn (0,42 a 17 Mmol L-(1)). Os limites de detecção (LOD) e de quantificação (LOQ) em termos de Sn foram de 15 Mg L(-1) (0,13 Mmol L(-1)) e 50 Mg L-1 (0,42 Mmol L(-1)), calculados utilizando a menor concentração dos picos dos analitos que podem ser diferenciados do sinal de fundo. A repetibilidade para o tempo de migração e área dos picos ficou próximo a 5 por cento. O método foi aplicado na análise de urina, sangue total e plasma fortificados com os OTs. Recuperações entre 75 e 95 por cento foram obtidas. No caso da determinação de sete pesticidas da classe das estrobilurinas (azoxistrobina, 9 dimoxistrobina, fluoxastrobina, picoxistrobina, piraclostrobina, trifloxistrobina e kresoxim-metil) em sopas infantis, foi usada a cromatografia eletrocinética capilar micelar (MEKC) com detecção fotométrica (no UV) com capilar de caminho óptico estendido. Um estudo multivariado, usando um planejamento 33 Box Behnken, indicou que a melhor separação para os pesticidas foi com solução aquosa de eletrólito composto por tampão tetraborato de sódio (5,1 mmol L(-1), pH 9,0) contendo 51 mmol L(-1) de dodecil sulfato de sódio (SDS) e 24 por cento acetonitrila (ACN) em volume. As condições instrumentais foram 25 C e mais 30 kV de diferença de potencial aplicada, 45 s de tempo de introdução hidrodinâmica de amostra e detecção em 210 nm. Para aumentar o poder de detecção, foi usada a concentração dos analitos no capilar. Para tal, as soluções de padrões e amostras foram dissolvidas em solução tampão tetraborato de sódio 45 mmol L(-1): acetonitrila 80:20 por cento v/v. As curvas analíticas apresentaram comportamento linear e os valores de LOD ficaram entre 7,0 Mg L(-1) ou 18 nmol L(-1) (piraclostrobina) a 15 Mg L-1 ou 33 nmol L(-1) (fluoxastrobina). Os valores de LOQ ficaram entre 21 Mg L(-1) ou 54 nmol L(-1) (piraclostrobina) a 45 Mg L(-1) ou 98 nmol L(-1) (fluoxastrobina). A repetibilidade ficou entre 1,7 a 7,9 por cento para a área de pico e entre 0,25 a 0,71 por cento para o tempo de migração. A precisão intermediária, avaliada com análises realizadas em diferentes dias, apresentou valores entre 1,3 a 5,3 por cento para a área de pico e entre 0,06 a 0,90 por cento para o tempo de migração. O método foi aplicado na análise de sopas prontas infantis fortificadas com as estrobilurinas. Os pesticidas foram extraídos aplicando o método QuEChERS com ajuste de pH com tampão acetato e limpeza com extração em fase sólida dispersiva. Os resultados das análises obtidos com um método cromatográfico adaptado da literatura foram estatisticamente iguais aos alcançados com o método proposto. A CZE foi o modo de separação escolhido para mostrar o potencial da determinação indireta de aminoglicosídeos com medição de fluorescência de pontos quânticos (excitação com laser de diodo em 410 nm) amplificada na presença dos analitos. A fotoluminescência dos pontos quânticos (nanopartículas de CdTe modificados com ácido tioglicólico monodispersas em solução) foi mais intensa em solução tampão (pH 8,0) contendo entre 5 e 10 mmol L(-1) de tetraborato de sódio. A interação no capilar entre aminoglicosídeos (neomicina e canamicina) e os pontos quânticos provocou aumento de fotoluminescência dependente do pH do meio (indício de interação de natureza 10 eletrostática). Alguns parâmetros de mérito foram avaliados com uma faixa linear curta (0,1 a 1,0 mol L(-1) para canamicina e 0,03 a 0,5 mol L(-1) para neomicina). Os valores mínimos detectados de 0,1 Mmol L(-1) ou 58 Mg L(-1) (canamicina) e 0,03 Mmol L(-1) ou 27 Mg L(-1) (neomicina) mostram que essa é uma abordagem interessante para a determinação sensível de aminoglicosídeos. / [en] In this work, analytical methods based on different approaches using capillary electrophoresis (CE) have been proposed. For the determination of organotins or OTs (diphenyltin and monophenyltin) in biological fluids, the separation using capillary zone electrophoresis (CZE) was applied using tandem with inductively coupled plasma mass spectrometry (CE-ICP-MS). The conditions for the analysis were optimized in an unvaried way aiming to find the conditions for the electrolyte solution (acetate buffer, 5.0 mmol L (-1), pH 2.8) and the employed instrumental parameters (45C, 30 kV and 30 s of the time for hydrodynamic introduction of the sample). A complementary solution was composed by NH4NO3 5.0 mmol L(-1), 10 por cento v/v of methanol and 1.0 g L(-1) of Cspositive in acetate buffer with pH adjusted to 2.8. The flow of this solution was set to 40 ML min(-1). The OTs were diluted either in a methanol: acetate buffer 50:50 por cento v/v solution or only in sodium acetate buffer pH 2.8. The conditions for detection by ICP-MS were set to 1200 W, 15 L min(-1) for the Ar plasma flow and 1,0 L min(-1) for the auxiliary Ar. The nebulizer Ar flow was adjusted daily. The monitored tin isotopes were 120Sn 118Sn. The isotope 133Cs was also monitored in order to control the efficiency and stability of the nebulization. The method presented a linear response between 0.05 and 2.0 mg L(-1) (0.42 a 17 Mmol L(-1)) for Sn. The value for the limits of detection (LOD) and for the limits of quantification (LOQ) for Sn were 15 Mg L(-1) (0.13 Mmol L-1) e 50 Mg L(-1) (0.42 Mmol L(-1)), calculated based on the lowest concentration of the analyte peaks that can be differentiated from the background signal. The repeatability for migration time and peak area was approximately 5 per cent. The method was applied in the analysis of organotin fortified blood and urine samples with recoveries between 75 and 95 per cent. In the case of the determination of seven strobilurin class pesticides (azoxystrobin, dimoxystrobin, fluoxastrobin, picoxystrobin, pyraclostrobin, trifloxystrobin and kresoxim-methyl) in baby food (vegetable and fruit soups), 12 the micellar electrokinetic capillary chromatography (MEKC) was used using photometric detection (UV) in a capillary with extended optical path. A multivariate study, with 33 Box Behnken design, indicated the best composition for the electrolytic solution to separate the seven pesticides: a sodium tetraborate buffer (5.1 mmol L(-1), pH 9.0) solution containing 51 mmol L(-1) sodium dodecyl sulfate and acetonitrile (24 por cento in volume). The instrumental conditions were 25C, 30 kV of applied voltage, 45 s for hydrodynamic introduction of the sample and detection at 210 nm. To increase the detection power, the concentration of the analytes into the capillary was used by using the Normal Stacking Mode. For this purpose, the solutions of standards and samples were prepared in 45 mmol L(-1) sodium tetraborate buffer solution: acetonitrile 80:20 por cento v/v. The analytical curves presented a linear behavior and the LOD values were between 7.0 Mg L (-1) or 18 nmol L(-1) (pyraclostrobin) to 15 Mg L(-1) or 33 nmol L(-1) (fluoxastrobin). The LOQ values were between 21 Mg L(-1) or 54 nmol L(-1) (pyraclostrobin) a 45 Mg L(-1) ou 98 nmol L(-1) (fluoxastrobin). The repeatability was between 1.7 to 7.9 por cento for the peak area and between 0.25 to 0.71 por cento for the migration time. The intermediate precision, evaluated by the analysis performed in different days were between 1.3 to 5.3 por cento for the peak area and between 0.06 and 0.90 per cent for the migration time. The method was applied in the analysis of baby food spiked with strobilurin. Pesticides were extracted using the QuEChERS method with pH adjustment with acetate buffer and clean-up using the dispersive solid phase extraction. The analysis results were statistically identical to those obtained with a chromatographic method adapted from the literature. The CZE separation mode was chosen to evaluate the potential of the indirect determination of aminoglycosides through the amplified photoluminescence from quantum dots (excitation laser diode 410 nm) in the presence of the analytes. The photoluminescence from quantum dots (monodispersed CdTe nanoparticles modified with thioglycolic acid) was more intense in buffer solution (pH 8.0) containing between 5 and 10 mmol L(-1) sodium tetraborate. The interaction between aminoglycosides (kanamycin and neomycin) and quantum dots inside the capillary caused the increasing of fluorescence in a pH-dependent way (indicating the electrostatic nature for the interaction). A few figures of merit were evaluated with a short linear range (0.1) to 1.0 Mmol L(-1) for kanamycin and 0.03 to 0.5 Mmol L(-1) for neomycin). The 13 minimum values detected were 0.1 nmol L(-1) or 58 Mg L(-1) (kanamycin) and 0.03 nmol L(-1) or 27 Mg L(-1) (neomycin) showing that the proposed approach can be used to detect aminoglycosides in a relatively sensitive way.
32

[en] A EXPERIMENTAL STUDY OF AROMATIC PRECURSORS AND SOOT DISTRIBUTION FOR A LAMINAR ETHYLENE COFLOW DIFFUSION FLAME / [pt] ESTUDO EXPERIMENTAL DA DISTRIBUIÇÃO DE FULIGEM E DE HIDROCARBONETOS AROMÁTICOS POLICÍCLICOS EM CHAMAS LAMINARES NÃO PRÉ-MISTURADAS DE ETILENO E DE AR

JUAN JOSE CRUZ VILLANUEVA 01 March 2018 (has links)
[pt] O presente trabalho apresenta um estudo experimental da distribuição da fuligem e de hidrocarbonetos aromáticos policíclicos (PAH) em chamas laminares não pré-misturadas de etileno e ar, mediante o uso de técnicas de diagnóstico espectroscópico, num queimador tipo co-flow. Para este fim são aplicadas as técnicas de fluorescência induzida por plano laser e incandescência induzida por plano laser, com excitação no espectro ultravioleta. Bandas espectrais de detecção centradas em 340, 400, 450, 500, 550 nm são empregadas para caracterizar diferentes PAH, aproveitado o fenômeno do deslocamento do espectros de fluorescência para o infravermelho, conforme se incrementa sua massa molecular. A técnica de extinção laser é utilizada para calibrar os resultados de incandescência e obter a fração volumétrica de fuligem. A radiação espontânea emitida pela fuligem é utilizada para medir a temperatura pela técnica de termometria em duas cores. A comparação dos resultados obtidos com uma detecção simultânea (0 ns) e atrasada (50 ns) com respeito ao pulso laser permite discriminar entre as regiões onde estão presentes PAHs e fuligem ou apenas fuligem. Os resultados mostram que na região mais fria, perto da entrada de combustível, apenas existem PAH. Seguindo esta região, numa zona de altura intermediária e mais quente, tanto a fuligem como o PAHs coexistem até a o ponto de máxima fração volumétrica integrada de fuligem. O deslocamento no sentido vertical da distribuição de fluorescência é observado com o aumento do comprimento de onda de detecção, o que é consistente com o crescimento do tamanho de PAH e sua progressiva transformação em fuligem. A distribuição de PAH e da fuligem é investigada como função da vazão de combustível. A fração volumétrica de fuligem apresenta uma distribuição clássica, cujo valor se incrementa com a vazão de combustível, enquanto que a temperatura medida diminui. / [en] This work presents an experimental study of soot and polycyclic aromatic hydrocarbons (PAH) distribution in axisymmetric ethylene-air non-premixe laminar flames using spectroscopic diagnostic in a co-flow target burner. For this purpose, are applied laser-induced fluorescence and laser-induced incandescence techniques with UV excitation. Spectral detection bands centered at 340, 400, 450, 500, 550 nm are employed to characterize PAH, using the infrared fluorescence spectra displacement phenomenon with the molecular mass increase. The incandescence is captured at 400 nm and the laser extinction technique is used to calibrate the signal, and, thus to obtain the soot volume fraction at the reaction zone. The soot spontaneous emitted radiation is used to measure the temperature by the two-color pyrometry technique. The comparison between results with prompt (0 ns) and delayed (50 ns) detection, with respect to the laser pulse, allows to discriminate the regions between soot precursors (PAH) and soot. The results show that, in the colder region, near the fuel inlet, PAH exist only. Following this region, in an intermediate warmer zone, both soot and PAH appear to coexist until the point of maximum integral soot volumetric fraction. A vertical displacement of the fluorescence distribution with increasing detection wavelength is observed, which is consistent with PAH size growth and with its progressive transformation into soot. PAH and soot distribution are investigated as a function of the fuel flow rate. The soot volumetric fraction exhibits a classical distribution, whose value increases with the fuel flow rate, whereas the measured temperature decreases, exhibiting a singular behavior in the region where the soot is formed.
33

[en] ANALYTICAL METHODS BASED ON PHOTOCHEMICALLY INDUCED FLUORESCENCE: SPECTROFLUORIMETRIC AND CHROMATOGRAPHIC APPLICATIONS FOR THE DETERMINATION OF TETRABENAZINE, AMITRIPTYLINE AND VARENICLINE / [pt] MÉTODOS ANALÍTICOS BASEADOS NA INDUÇÃO FOTOQUÍMICA DE FLUORESCÊNCIA: APLICAÇÕES ESPECTROFLUORIMÉTRICAS E CROMATOGRÁFICAS PARA A DETERMINAÇÃO DE TETRABENAZINA, AMITRIPTILINA E VARENICLINA

27 December 2021 (has links)
[pt] A derivatização fotoquímica foi utilizada para induzir ou amplificar a fluorescência de três substâncias utilizadas como princípios ativos em medicamentos: tetrabenazina (TBZ), amitriptilina (AMT) e vareniclina (VRN). Com o aumento de fluorescência após o tratamento com radiação UV, métodos espectrofluorimétricos foram desenvolvidos para determinar a concentração de TBZ, a AMT e a VRN em medicamentos e em matrizes biológicas. A avaliação da abordagem por cromatografia líquida de alta eficiência (HPLC) com detecção por fluorescência tambme foi avaliada para a AMT e VRN. Para a determinação de TBZ, a irradiação por 60 min em meio de NaOH (0,45 mol L-1) permitiu a sua quantificação espectrofluorimétrica com um limite de detecção (LD) de 1,4 x 10-8 mol L-1 e faixa linear até 1,0 x 10-5 mol L-1. O método espectrofluorimétrico foi aplicado para determinar TBZ no medicamento com recuperações entre 88 e 95%. A TBZ também foi determinada em saliva fortificada com o analito em concentração próxima ao do limite de quantificação (LQ) com recuperações maiores que 87%. Estudos usando espectrometria de massas com desorção de plasma estimulada por uma fonte de 252Cf foram realizados para identificar a estrutura do fotoderivado, indicando a fotólise da TBZ via reação de Norrish tipo I e II. Para a determinação de AMT, duas abordagens de derivatização fotoquímica permitiram determinar a substância por espectrofluorimetria e por HPLC. Para o método espectrofluorimétrico, a derivatização foi realizada expondo ao UV por 60 min uma solução de AMT, preparada em HCl 0,027 mol L-1. A faixa de resposta linear se estendeu até 1,0 x 10-5 mol L-1 de AMT com um LD de 4,8 x 10-8 mol L-1. Na abordagem cromatográfica, o processo de derivatização da AMT foi ajustado utilizando 30 min de UV em tampão fosfato pH 3. O método permitiu um LD de 6,9 x 10-9 mol L-1 com faixa linear até 2,5 x 10-6 mol L-1 de AMT. Os métodos desenvolvidos foram aplicados na determinação de AMT em medicamento e em material de referência farmacopéico com recuperações entre 94 e 105% para o método fluorimétrico e entre 99 e 111% para a abordagem cromatográfica. A aplicação na determinação da AMT em plasma humano fortificado na concentração de 1,0 x 10-6 mol L-1 forneceram resultados aceitáveis. Os fotoderivados fluorescentes foram separados e identificados por GC-MS, sendo proposto um mecanismo de fotólise da AMT. Para a determinação de VRN, a derivatização fotoquímica em meio básico permitiu a determinação da substância por espectrofluorimetria, sendo também avaliada uma abordagem por HPLC. A derivatização da VRN, realizada expondo o analito ao UV por 23 min em solução de NaOH 0,64 mol L-1, permitiu um LD de 1,5 x 10-8 mol L-1 e uma faixa linear até 1,0 x 10-6 mol L-1. As condições de fotoderivatização também foram adaptadas para a determinação cromatográfica do analito, irradiando-o por 10 min em meio de tampão borato (0,01 mol L-1 pH 10). A aplicação na determinação da VRN no medicamento com recuperações entre 93 e 102% foi alcançada. Para todos os métodos desenvolvidos foi realizada uma análise metrológica simplificada contemplando as fontes de incerteza mais relevantes para o processo de medição dos analitos: o preparo de soluções; a repetibilidade; a precisão intermediária e a curva analítica. As incertezas de medição para cada um dos métodos propostos foram estimadas em três concentrações distintas, no início, no meio e no fim da faixa linear. Os resultados obtidos foram entre 5,8 e 36% de incerteza do valor nominal das concentrações próximas ao LQ e entre 3,1 e 16% para as concentrações dentro na faixa linear dos métodos. Em todos os métodos desenvolvidos foram utilizados procedimentos de derivatização seguros, energeticamente eficientes e com redução de uso de solventes e substâncias tóxicas, em concordância com os princípios da química verde. / [en] Photochemical derivatization was employed to induce or amplify the fluorescence from three substances with pharmacological activities: tetrabenazine (TBZ); amitriptyline (AMT) and varenicline (VRN). The substantial fluorescence enhancement after UV irradiation allowed the development of methods based on spectrofluorimetry for TBZ, AMT and VRN. The approach was also evaluated in high performance liquid chromatography (HPLC) with fluorimetric detection for the determination of the concentration AMT and VRN in drugs or in biological matrices. For the determination of TBZ, 60 min of UV irradiation of the analyte prepared in NaOH (0.45 mol L-1) allowed its indirect quantification using spectrofluorimetry, with a limit of detection (LOD) of 1.4 x 10-8 mol L-1 and a linear response up to 1.0 x 10-5 mol L-1. Pre-concentration using solid phase extraction improved the LOD in one order of magnitude. The spectrofluorimetric method was applied for the determination of TBZ in a commercial drug, with recoveries between 88 and 95%. TBZ was also determined in analyte fortified saliva at a concentration near the limit of quantitation (LOQ) with recoveries greater than 87%. Studies using plasma desorption mass spectrometry with a 252Cf source, indicated that the photoderivatives of TBZ were obtained through a Norrish Type I and II TBZ photolysis. For the determination of AMT, two photochemical derivatization approaches allowed the determination of the substance by spectrofluorimetry. The approach using HPLC coupled to fluorescence detection was also tested. For the spectrofluorimetric method, the derivatization was achieved after 60 min of UV exposure of a solution of AMT prepared in HCl 0.027 mol L-1. The linear response of the method was up to 1.0 x 10-5 mol L-1 of AMT, with a LOD of 4.8 x 10-8 mol L-1. For the chromatographic method, the derivatization process was adjusted (30 min of UV irradiation in phosphate buffer, pH 3) in order to adapt the reaction for HPLC. The method allowed an LOD of 6.0 x10-9 mol L-1 with a linear range up to 2.5 x 10-6 mol L-1 of AMT. The determination of AMT in drugs and in a pharmacopeial reference material was performed, with recoveries between 94 and 105% for the fluorimetric method and between 99 and 111% using HPLC. The analysis of human plasma was also made using AMT (1.0 x 10-6 mol L-1) fortified samples. The fluorescent photoderivatives were separated and identified by GC-MS, which allowed the proposal of a photolysis mechanism of AMT. For the determination of VRN, the photochemical derivatization in basic medium allowed the determination of the substance by spectrofluorimetry. The derivatization of VRN, performed by exposing the analyte to the UV during 23 minutes in NaOH 0.64 mol L-1, allowed a LOD of 1.5 x10-8 mol L-1 and a linear range extending up to 1.0 x10-6 mol L-1. The derivatization condition were also adapted for the determination of the analyte using HPLC with fluorimetric detection, by irradiating VRN for 10 min in borate buffer (0.01 mol L-1 pH 10). Both methods were applied for the determination of VRN in a commercial drug, with recoveries between 93 and 102%. For all the developed methods, a simplified metrological evaluation was performed, considering the most relevant sources of uncertainty during the measurement process of the analytes studied in this thesis: solution preparation, intra and inter-day precision and the analytical curve. The uncertainty sources for each of the proposed methods were estimated in three different concentrations within the linear range. Measurement uncertainty estimations were between 5.8 and 36% of the nominal concentration in the concentrations near the LOQ and between 3.1 and 16% in the concentrations within the linear range of the methods. Safer, energetically efficient procedures with solvent reduction and without the use of toxic reagents were proposed, in agreement to green chemistry principles.
34

[en] A PRELIMINARY STUDY CONCERNING THE PERFORMANCE OF GRAPHENE QUANTUM DOTS AND BENZOTHIADIAZOLE-BASED PIGMENTS AS CHEMICAL MARKERS IN SECURITY INKS / [pt] ESTUDO PRELIMINAR DO DESEMPENHO DE PIGMENTOS À BASE DE PONTOS QUÂNTICOS DE GRAFENO E BENZOTIADIAZOLAS COMO MARCADORES QUÍMICOS FOTOLUMINESCENTES EM TINTAS DE SEGURANÇA

RAQUEL DA CUNHA MARTINS SILVA 30 September 2021 (has links)
[pt] No presente trabalho realizou-se um estudo preliminar do desempenho de três luminóforos, sendo eles um composto a base de pontos quânticos de grafeno (GQDs) e dois compostos do tipo benzotiadiazola (BTDs), na formulação de tintas de segurança, com a intenção de avaliar a capacidade dessas substâncias de conferirem a um determinado produto características de autenticidade, durabilidade e confiabilidade metrológica. Para tal, foi desenvolvida uma sequência de ensaios a serem aplicados em formulações de tintas líquidas contendo o pigmento. As tintas formuladas foram submetidas a testes de durabilidade, incluindo resistências químicas, físicas e mecânicas. A exposição contínua a luminosidade promoveu degradação precoce das amostras contendo GQDs (nível 1 escala de lã azul), que foi então descartada com opção viável. Os testes prosseguiram para as tintas contendo BTDs, onde apenas uma das formulações foi aprovada quanto ao teste de abrasão contra papel. No tocante às resistências químicas e ao calor, as BTDs apresentaram desempenho aceitável, atendendo aos requisitos da norma técnica ISO 10373-1 e do documento orientativo publicado pela Organização da Aviação Civil Internacional – OACI (em inglês, ICAO), para qualidade de cartões inteligentes e passaportes. Após tratamento estatístico dos dados, considerando o teste de Mann-Whitney como ferramenta de avaliação, foi possível concluir que a amostras a base de BTDs, ora denominada BTD-01, apresentou desempenho satisfatório para aplicação como marcador de segurança. / [en] In the present work a preliminary study regarding the evaluation of two BTD-based compounds and graphene quantum dots (GQDs) as luminophores in the formulation of security inks was achieved. The intention was to determine the ability of these substances to promote to a given product characteristics of authenticity, durability and, metrological reliability. For this purpose, a sequence of tests was developed using liquid inks containing the pigments on its formulations. The formulated inks were subjected to durability tests, including chemical, physical and mechanical resistances. Continuous exposure to light led to early degradation of samples containing GQDs (level 1 blue wool scale), which was then discarded as a viable option. The inks containing BTDs where further explored, where only one of the formulations was approved at the quartant abrasion test against paper. Regarding the chemical and heat resistance, the BTDs presented acceptable performance, meeting the requirements of the ISO 10373-1 technical standard and the guidance document published by the International Civil Aviation Organization - ICAO, for the quality of smart cards and passports. After statistical treatment of the data, considering the Mann-Whitney test as an evaluation tool, it was possible to conclude that the samples based on BTDs, here called BTD-01, presented satisfactory performance for application as a security taggant.

Page generated in 0.0348 seconds