• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] SARDAN - ONE PROGRAM TO TRANSIENT SIMULATION IN TYPICAL PWR NUCLEAR POWER PLANTS / [pt] SARDAN: UM PROGRAMA PARA SIMULAÇÃO DE TRANSITÓRIOS NUMA USINA PWR TÍPICA

RODOLFO LUIZ PEIXOTO DE MATTOS SANTOS 10 January 2012 (has links)
[pt] No projeto de uma usina nuclear do tipo PWR, é necessário a verificação de que, nas diversas condições de operação, em regime permanente ou transitório, os limites de projeto de seus componentes não sejam atingidos. No presente trabalho, é desenvolvido um programa em linguagem FORTRAN-IV que simula o comportamento do circuito primário de uma usina PWR típica em transitórios de condição II, em particular os acidentes de retirada descontrolada de um conjunto de barras de controle, queda de um conjunto de barras de controle e diluição descontrolada de boro. No modelo matemático adotado, são tratados o núcleo do reator, a tubulação quente, com pressurizador acoplado, o gerador de vapor, e a tubulação fria. Os resultados obtidos na análise dos citados acidentes são comparados com os constantes no relatório final de análise de segurança da usina Almirante Álvaro Alberto, unidade Angra-I (FSAR), e considerados satisfatórios. / [en] In a PWR nuclear power plant design it`s necessary to verify that, in many operation conditions, at steady state or transients, its components conditions are always below design limits. In this work, is developed a code in FORTRAN-IV language that simulates primary loop behavior of a typical PWR power plant in condition II transients, in particular the accidents of uncontrolled rod cluster control assembly bank withdrawal, rod cluster control assempbly drop and uncontrolled boron dilution. In this model are treated the reactor core, the hot-leg with a pressurizer coupled, the steam generator and the cold-leg. The results obtained are plotted against that of the final safety and analysis report of the Almirant Álvaro Alberto plant, unity Angra-I (FSAR), and considered satisfactory.
2

[en] THERMOHIDRAULIC MODEL FOR A TYPICAL STEAM GENERATOR OF PWR NUCLEAR POWER PLANTS / [pt] MODELO TERMOHIDRÁULICO PARA GERADOR DE VAPOR TÍPICO DE USINAS PWR

CARLOS VALOIS MACIEL BRAGA 07 October 2011 (has links)
[pt] Muitas centrais nucleares do tipo PWR utilizam vapor produzido em geradores de vapor do tipo tubos em U invertido, com recirculação interna natural, nos quais o fluido primário escoa internamente aos tubos e o secundário, entre os tubos e a carcaça. No presente trabalho, é desenvolvido um modelo de simulação termohidráulica, para regime permanente, de tais geradores de vapor, considerando-se o escoamento secundário divididas em duas partes, individualmente homogêneas, e com troca de calor e massa entre elas. O título da mistura bifásica que alimenta a turbina é fixado e a pressão da água de alimentação é determinada. Baseado neste modelo, desenvolveu-se o programa GEVAP, em linguagem Fortran-IV. O modelo é aplicado ao gerador de vapor da central Angra II e os resultados obtidos são comparados com dados de projeto da KWU, sendo considerados satisfatórios. / [en] Many PWR power plants use steam produced in steam generators with inverted U tubes with natural internal recirculation, in which the primary fluid flows inside the tubes and the working fluid, between the tubes and the shell. In the present work, it is developed a model of termohidraulic simulation, for steady state, considering the scondary flow divided in two parts individually homogeneous, and with heat and mass transferences between them. The quality of the two-phase mixture that is fed to the turbine is fixed and, based on this value, the feedwater pressure is determined. The recirculation ratio is intrinscally determined. Based on this model is applied to the steam generator of the Angra II nuclear power palnt and the results are compared with KWU’s design parameters, being considered satisfactory.
3

[en] GENERATION OF OPTICAL SHORT PULSES AND TIME DOMAIN MULTIPLEXING / [pt] GERAÇÃO DE PULSOS ÓPTICOS CURTOS E MULTIPLEXAÇÃO NO DOMÍNIO DO TEMPO

12 March 2007 (has links)
[pt] Esta dissertação de mestrado demonstra o princípio do funcionamento de um sistema gerador e multiplexador óptico utilizando pulsos curtos. Através do efeito de mode locked fiber ring laser pulsos curtos ópticos são gerados para taxa de repetição de 2.48 GHz ao passo que o escalonamento é atribuído ao uso de dispositivos passivos ópticos os quais compõem o conjunto experimental permitindo que a freqüência de 9.95 GHz seja atingida mediante a combinação exata das técnicas utilizadas. O coração de sistema está contido na geração e controle dos pulsos os quais determinarão a taxa de repetição em baixa freqüência e posteriormente a multiplexação através de linhas de atraso devidamente combinadas fornecerão o valor escalonado de operação de frequência. / [en] This master thesis demonstrates the principle of the functioning of an optical time domain multiplex system using short pulses. Through the effect of mode locked to fiber ring laser, optical short pulses are generated at repetition of 2.48 GHz to the step that the scheduling is attributed to the use of optic passive devices which compose the experimental setup allowing that the frequency of 9.95 GHz is reached by means of the accurate combination of the used techniques. The system heart is contained in the generation and control of the pulses which will later determine the rate of repetition in low frequency and multiplexing through lines of delay duly combined.
4

[en] DETECTION, SEPARATION E CLASSIFICATION OF PARTIAL DISCHARGE SIGNALS IN HIGH VOLTAGE INSULATIONS / [pt] DETECÇÃO, SEPARAÇÃO E CLASSIFICAÇÃO DE SINAIS DE DESCARGAS PARCIAIS EM ISOLAMENTOS DE ALTA TENSÃO

THIAGO BAPTISTA RODRIGUES 03 November 2020 (has links)
[pt] A medição e classificação de descargas parciais constituem uma importante ferramenta de avaliação dos sistemas de isolamento utilizados em equipamentos de alta tensão. Após o pré-processamento dos dados, que captura, digitaliza e filtra o sinal de descargas parciais, geralmente eliminando os ruídos, existem basicamente duas etapas principais, que são a extração de características e a classificação de padrões. As descargas parciais contêm um conjunto de características discriminatórias únicas que lhes permitem ser reconhecidas. Assim, o primeiro procedimento no processo de classificação é definir quais delas podem ser utilizadas e qual o método de extração destas características. O fenômeno de descargas parciais tem uma natureza transitória e é caracterizado por correntes pulsantes com uma duração de vários nanossegundos até poucos microssegundos. Sua magnitude não é sempre proporcional ao dano causado, sendo que descargas de pequena magnitude podem levar rapidamente à evolução de um defeito. Por isso a necessidade de se entender bem este fenômeno e saber interpretar os dados. Além disso, equipamentos de alta tensão de grande porte, como motores e geradores, podem apresentar mais de uma fonte interna de descargas parciais, sendo importante separar os sinais dessas diferentes fontes antes de realizar a classificação. No caso de outros equipamentos de alta tensão de menor porte, como para-raios e transformadores de corrente de subestação, a simples detecção da presença de descargas parciais interna ao equipamento, independente do número de fontes, já é suficiente para indicar a retirada de operação destes equipamentos, dado seu baixo custo relativo e o elevado grau de importância destes para a confiabilidade do sistema onde estão inseridos. Para um diagnóstico completo e confíável de isolamentos de alta tensão, há a demanda por um sistema de análise capaz de promover com eficácia a detecção de descargas parciais internas aos equipamentos, a separação das diversas fontes de descargas parciais, no caso dos equipamentos de grande porte, bem como realizar a correta classificação do tipo de defeito, com base principalmente na análise das características discriminantes das diferentes fontes e na assinatura dos sinais para os diferentes defeitos. Este estudo contribui para o preenchimento desta lacuna, apresentando metodologias que se mostram robustas e precisas nos testes realizados, de modo que possam efetivamente orientar os especialistas em manutenção na tomada de decisões. Para fazer isso, são propostas novas variáveis capazes de extrair informações relevantes de sinais no tempo medidos em diversos tipos de isolamentos, sendo aplicadas aqui em dados obtidos em campo e em laboratório para avaliar sua eficácia na tarefa. Essas informações são tratadas utilizando técnicas de classificação de padrões e inteligência artificial para determinar de forma automática a presença de descargas parciais, o número de fontes diferentes e o tipo de defeito nos isolamentos de alta tensão utilizados no estudo. Outra contribuição do estudo é a criação de um banco de dados histórico, baseada em processamento de imagem, com padrões de mapas de descargas parciais conhecidos na literatura em máquinas rotativas, para serem utilizados na classificação de novos mapas medidos neste tipo de equipamento. / [en] Measurement and classification of partial discharges are an important tool for the evaluation of insulation systems used in high voltage equipments. After pre-processing of data, which captures, scans and filters the signal of partial discharges, generally eliminating noises, there are basically two main steps, which are the extraction of characteristics and the pattern classification. Partial discharges contain a set of unique discriminatory characteristics that allow them to be recognized. Thus, the first procedure in the classification process is to define which of them can be used and which is the method for extraction of those characteristics. The phenomenon of partial discharges has a transient nature and is characterized by pulsating currents with a duration of several nanoseconds up to a few microseconds. Its magnitude is not always proportional to the damage caused, and discharges of small magnitude can quickly lead to the evolution of a failure. Therefore the need to understand this phenomenon well and to know how to interpret the data. In addition, large high voltage equipments such as motors and generators may have more than one internal source of partial discharges, and it is important to separate the signals from those different sources prior to classification. In the case of smaller high voltage equipments, as surge arrester and substation current transformers, the simple detection of the presence of partial discharges inside the equipment, regardless of the number of sources, is sufficient to indicate the withdrawal of operation of the equipment, given their low relative cost and the high degree of importance of these to the reliability of the system where they are part of. For a complete and reliable diagnosis of high voltage insulations, there is a demand for an analysis system capable of effectively promoting the detection of the partial discharges internal to the equipments, the separation of the various sources of partial discharges in the case of large equipments, as well as to carry out the correct classification of the type of failure. The system should be based mainly on the analysis of the discriminating characteristics of the different sources and the signature of the signals for the different failure. This study contributes to fill this gap by presenting methodologies that are robust and accurate in the tests performed, so that they can effectively guide maintenance specialists in decision making. To do this, new variables are proposed to extract relevant information from time signals measured in various types of insulations, being applied here in field and laboratory data to evaluate their effectiveness in the task. This information is treated using standard classification techniques and artificial intelligence to automatically determine the presence of partial discharges, the number of different sources and the type of defect in the high voltage insulations used in the study. Another contribution of the study is the creation of a historical database, based on image processing, with partial discharge map patterns known in the literature on rotating machines, to be used in the classification of new maps measured in this type of equipment.
5

[pt] REPRESENTAÇÃO ESTOCÁSTICA PARA SOLUÇÕES DO PROBLEMA DE DIRICHLET PARA EQUAÇÕES DIFERENCIAIS PARCIAIS ELÍPTICAS / [en] STOCHASTIC REPRESENTATION FOR SOLUTIONS OF THE DIRICHLET PROBLEM FOR ELLIPTIC PARTIAL DIFFERENTIAL EQUATIONS

CLAUSON CARVALHO DA SILVA 01 September 2016 (has links)
[pt] Como motivação, apresentaremos alguns problemas que ilustram a conexão entre a teoria da probabilidade e algumas equações diferenciais parciais. Suas soluções mesclam os dois assuntos e provocam a suspeita de que alguns processos estocásticos e operadores diferenciais caminham juntos. Em seguida, exibiremos a teoria das difusões de Itô. Mostraremos algumas de suas características, como a propriedade de Markov e cada um destes processos possuirá o que chamaremos de gerador infinitesimal da difusão. Este será um operador diferencial de segunda ordem cujo estudo detalhado revela características do processo. Apresentaremos também a fórmula de Dynkin. Com essas ferramentas probabilísticas, encontraremos uma representação estocástica para a solução do problema de Dirichlet para operadores diferenciais elípticos, generalizando as soluções dos problemas inicialmente propostos. / [en] Firstly, for motivation purposes, we briefly present a few problems mixing notions of probability theory and of partial differential equations (PDE). In discussing the solution to such problems it will become apparent that some stochastic process and differential equations walk together. Next, we introduce a class of stochastic processes called the Ito diffusions, and some of its features such as the Markov property. Each such process has an associated linear operator the, so called, infinitesimal generator. This operator acts as a second-order differential operator on smooth functions, and controls the LOCAL behavior of these diffusions. We discuss these features together with Dynkin s formula a convenient relation derived from the infinitesimal generator, which informs us about the AVERAGE behavior of the diffusion. Finally, we apply these probabilistic tools to find a formula for the solution of the Dirichlet problem for a somewhat general linear elliptic second order PDE. This formula connects the solution of the PDE to the aggregated/average behavior and associated (Ito) diffusion. This type of stochastic representation generalizes the solution method of the problems firstly discussed.
6

[pt] ANÁLISES ESTÁTICA E DINÂMICA DA ATUAÇÃO DE EQUIPAMENTOS DE CONTROLE NA ESTABILIDADE DE TENSÃO / [en] STATIC AND DYNAMIC ANALYSES OF CONTROL DEVICE EFFECTS ON VOLTAGE STABILITY

MARCOS VINICIUS PIMENTEL TEIXEIRA 19 October 2016 (has links)
[pt] O problema da estabilidade de tensão está associado à máxima injeção de potência em barras da rede e à possibilidade do controle de tensão ter o efeito oposto ao esperado. Alguns casos reais de blecaute, caracterizados por afundamento de tensão, sugerem que os procedimentos normais para o controle de tensão do sistema podem agravar ainda mais o problema. Isso ocorreria porque, em determinadas situações especiais, caracterizadas pela relação inversa entre as variáveis de controle dos equipamentos, as ações de controle teriam o efeito oposto ao esperado da sua lógica de projeto. Esta afirmação é baseada no critério de estabilidade de tensão a pequenas perturbações que diz: Dada uma condição de operação para cada barra no sistema, o sistema é estável caso o módulo da tensão na barra aumente à medida que a injeção de potência reativa nessa mesma barra é aumentada. Um sistema é instável se, para pelo menos uma barra no sistema, o módulo de tensão da barra diminui conforme a injeção de potência reativa nessa barra é aumentada. Adicionalmente, o critério da curva 𝑉𝑄 diz: Uma vez que todos os dispositivos de controle de potência reativa são projetados para funcionar satisfatoriamente quando um aumento em 𝑄 é acompanhado por um aumento em 𝑉, a operação do lado direito das curvas 𝑉𝑄 é estável e do lado esquerdo é instável. Além disso, a parte inferior da curva 𝑉𝑄 representa o limite de estabilidade e define o valor de potência reativa mínimo para uma operação estável. Esse efeito não esperado do controle poderia causar tensões excessivamente baixas (ou altas) para a operação normal do sistema e provocar consequências indesejáveis. Visto isso, esse trabalho tem como principal objetivo investigar, no domínio do tempo, o efeito das ações de controle de tensão em pontos onde as variáveis de controle dos equipamentos apresentam relação inversa e, assim, validar (ou não) os resultados estimados pelos métodos baseados em análise estática como, por exemplo, os critérios de estabilidade de tensão a pequenas perturbações e da curva 𝑉𝑄. As simulações dinâmicas mostram que a análise estática não pode ser aplicada a todos os tipos de equipamentos que controlam a tensão. Outra possível causa do problema da estabilidade de tensão está relacionada à atuação de limitadores de sobre-excitação de máquinas síncronas e, por esta razão, é proposto um método para identificar as máquinas propensas a atingir o limite de sobre-excitação em estudos de regime permanente. No entanto, a atuação desses limitadores, na grande maioria das vezes, não apresenta efeito prejudicial na estabilidade do sistema e, por isto, também é proposto um critério que aponta a iminente perda da estabilidade devido à atuação dos limitadores. Este critério pode ser útil na concepção de esquemas automáticos de rejeição de carga, a fim de impedir a perda de estabilidade, e ele também pode ser utilizado em avaliações de segurança online para alertar sobre possíveis riscos de instabilidade e, consequentemente, para indicar ações preventivas. / [en] The voltage stability problem is associated with the maximum power injection in the network and the possibility of the voltage control having the opposite effect. Some real cases of blackouts characterized by voltage decays suggest that normal procedures for automatic voltage control can adversely affect the voltage level in the system. This may have been because in special situations, characterized by an inverse relationship between the controls variables in the devices used to control the system voltage, the automatic voltage control can have the opposite effect to that expected based on the design logic. This statement is based on the criterion for small-disturbance voltage stability: At a given operating condition for every bus in the system, a system is voltage-stable if the bus voltage magnitude increases as the reactive power injection at the same bus is increased. A system is voltage-unstable if, for at least one bus in the system, the bus voltage magnitude decreases as the reactive power injection at the same bus is increased. In addition, it is based on the 𝑉𝑄 curve criterion: Since all reactive power control devices are designed to operate satisfactorily when an increase in 𝑄 is accompanied by an increase in 𝑉, operation on the right side of the 𝑉𝑄 is stable and on the left side is unstable. Besides, the bottom of the 𝑉𝑄 curve represents the stability limit and defines the minimum reactive power requirement for stable operation. The unexpected control effect could produce excessively low (or high) voltages for normal system operation and cause undesirable consequences. In light of this, the present work seeks to analyze in the time domain the effects of device control actions starting from points where the control variables are inversely related and validated (or not) the results estimated by methods based on static analysis, for example, the criterion for small-disturbance voltage stability and 𝑉𝑄 curve. Dynamic simulations show that static analysis cannot be applied to all types of devices used to control the voltage. Another possible cause of the voltage stability problem is the action of overexcitation limiters. For this reason, it is proposed a way for identifying the machines that have a chance to hit the overexcitation limit in static analysis studies. However, in most cases, the action of these limiters has no detrimental effect on system stability and, therefore, it is also proposed a criterion that identifies the imminent loss of stability due to these limiters. This criterion may be useful in design of load shedding schemes, in order to prevent loss of stability, and can be used for online security assessment, warning for instability and indicating preventive actions.

Page generated in 1.8299 seconds