• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 2
  • Tagged with
  • 36
  • 36
  • 31
  • 31
  • 13
  • 11
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Adequação da qualidade microbiológica de efluentes de tratamento secundário de esgoto sanitário pela aplicação dos desinfetantes ozônio, permanganato de potássio e ácido peracético / Microbiological quality adequation of the wastewater secondary effluent by the application of ozone, potassium permanganate and peracetic acid desinfectants

Luci Sartori 10 December 2004 (has links)
Esta pesquisa abordou a influência do ozônio, ácido peracético e permanganato de potássio na inativação dos microrganismos indicadores E.coli, colifago, C.perfringens e Ascaris lumbricoides de efluentes secundários, visando reúso em agricultura. Os efluentes utilizados para os ensaios com ozônio foram provenientes da Estação de Tratamento de Esgoto da cidade de Lins-SP (o tratamento consiste em lagoa anaeróbia seguida de facultativa) e da Estação de Tratamento de Esgoto da cidade de Araraquara-SP, na qual o tratamento é constituído de lagoa aerada seguida de lagoa de sedimentação. Para os ensaios de desinfecção com ácido peracético e permanganato de potássio utilizou-se apenas o efluente da Estação de Tratamento de Esgoto da cidade de Araraquara-SP. Os ensaios de desinfecção demonstraram que o ácido peracético tem maior poder bactericida em relação ao ozônio e permanganato de potássio. O ozônio foi mais eficiente na inativação do microrganismo colifago. Para todos os desinfetantes usados, a concentração da bactéria esporulada C.perfringens permaneceu entre 103 a 104 NMP/100 mL. Todos os desinfetantes, nas concentrações e tempos de contatos testados, mostraram-se tóxicos nas primeiras 24 h ao microcrustáceo Daphnia similis. O desinfetante que alcançou, com menor concentração e tempo de contato, o padrão proposto pela OMS (1989) para irrigação irrestrita foi o ácido peracético com 5 mg/L e tempo de contato de 10 minutos. Já a concentração de ozônio consumida de 40 mg/L e tempo de contato de 10 minutos foram suficientes para atender ao padrão proposto para irrigação restrita. / This research deals with the influence of ozone, peracetic acid and potassium permanganate on the inactivation of indicator microorganisms E.coli, coliphage, Clostridium perfringens and Ascaris lumbricoides secondary effluents, aiming agricultural reuse. The effluents used for the analyses with ozone had been proceeding from the Lins-SP Wastewater Treatment Plant (the treatment consists of an anaerobic lagoon followed by a facultative one) and from the Araraquara-SP Wastewater Treatment Plant, where the treatment consists of an aerated lagoon followed by a sedimentation pond. For the disinfection analyses with peracetic acid and potassium permanganate only the effluent from the Araraquara-SP Wastewater Treatment Plant was used. The disinfection analyses demonstrated that the peracetic acid has greater bactericide power than ozone and potassium permanganate. Ozone was more efficient in the coliphage microorganism inactivation. For all used disinfectants the concentration of sporulated bacteria Clostridium perfringens remained between 103 and 104 NPM/100 mL. All the disinfectants, under the concentration and contact time tested, showed themselves toxic during the first 24 h, and did not show any mortality to the Daphnia similis microorganism after that period. The disinfectant that reached, under lower concentration and contact time, the proposed standard for unrestricted irrigation from WHO (1989) was the peracetic acid with 5 mg/L and contact time of 10 minutes.
22

Efectividad in vitro del ácido peracético frente a cepas de Escherichia coli y Listeria innocua

Vargas Palacios, Catalina Teresa January 2018 (has links)
Memoria para optar al título de Ingeniero en Alimentos / Para lograr la inocuidad de los alimentos, es necesario mantener la higiene dentro de todo el proceso productivo, ya sea en los operarios como en los equipos y materiales propios de la planta. Por esto, dentro de los planes de sanitización e higiene de cada industria, es importante la elección de los desinfectantes que se deben usar, ya que estos deben eliminar más del 99,999% de la población bacteriana presente en la superficie y no dejar residuos potencialmente tóxicos para el ser humano. Dentro de estos desinfectantes industriales se encuentra el ácido peracético, que es un perácido orgánico, corrosivo y con un alto poder oxidante, se comercializa como mezcla con agua oxigenada y ácido acético, estando el ácido peracético en una concentración del 95%. Este ácido se descompone rápidamente dejando como residuo agua, oxígeno y ácido acético, siendo inocuo para la salud humana. El objetivo de este estudio fue determinar la acción biocida del ácido peracético por medio de la cinética de muerte de las bacterias Listeria innocua (Gram+) y Escherichia coli (Gram-), y calcular el coeficiente de dilución del desinfectante para cada cepa estudiada. La acción biocida se determinó por medio de ensayos in vitro a tres tiempos de acción, 0,5, 1 y 2 min, y tres concentraciones del desinfectante, 300, 500 y 1000 ppm; el fabricante solo indicaba como modo de uso 1000 ppm de concentración, y no un tiempo de acción; con estos parámetros se determinó la eficiencia germicida (%E), el tiempo de reducción decimal (TRD) y la velocidad específica de muerte (k). Se determinó que este desinfectante es eficiente a una concentración de 300 ppm y un tiempo de acción de 2 min, con dicho tratamiento eliminó más del 99,999% de la población bacteriana de ambas cepas, se vio que el efecto biocida de este desinfectante es igual para ambos tipos de cepas, en donde se comparó los distintos parámetros, %E, TRD y k, por medio de un análisis ANOVA simple dando, en todos los casos, que no habían diferencias significativas entre Listeria innocua y Escherichia coli. Por último, el coeficiente de dilución resultó mayor que 1 para Listeria innocua, lo que indica que la eliminación de esta cepa por medio del APA depende más de la concentración que del tiempo de acción, e igual a 1 para Escherichia coli, lo que indica que su eliminación con APA depende tanto del tiempo de acción como de la concentración del desinfectante / To achieve the food safety, it’s necessary keep hygiene within the entire production process, either in the operators as in the equipment and materials of the plant. For this, in the sanitization and hygiene design of each industry, it’s important the choice of disinfectants that should be used, since these should remove more than 99,999% of the bacterial population present on the surface and do not leave potentially toxic waste for humans. Inside these industrial disinfectants the peracetic acid is found. It is an organic peracid, corrosive and with a high oxidizing power, it is marketed as a mixture with hydrogen peroxide and acetic acid, being the peracetic acid in a concentration of 95%. This acid decomposes quickly in water, oxygen and acetic acid, being safety for the human health. The aim of this study was determinate the biocidal action of peracetic acid by means of the death kinetics of the bacteria Listeria innocua (Gram+) and Escherichia coli (Gram-) and calculate the dilution coefficient of the disinfectant for each strain studied. The biocidal action was determinated by tests in vitro to three action time, 0,5, 1 and 2 min and three disinfectant concentration, 300, 500 and 1000 ppm; the manufacturer only indicated 1000 ppm concentration as the mode of use, and not an action time; with theses parameters was determinated the germicidal efficiency (%E), decimal reduction time (DRT), and the specific constant of death (k). It was determined that this disinfectant is efficient to 300 ppm of concentration and 2 min of action time, with this treatment was removed more than 99,999% of the bacterial population of both strain, it was seen that the biocidal effect of this disinfectant was the same for both type of strain, where the different parameters, %E, DRT and k, were compared by means of a simple ANOVA analysis giving, in all cases, that there were no significant differences between Listeria innocua and Escherichia coli. Finally, the dilution coefficient was greater than 1 for Listeria innocua, that means that the elimination this strain by means PAA depend more of concentration that of action time, and equal than 1 for Escherichia coli, that means that the elimination this strain by means PAA depends of both, the action time and the concentration of the disinfectant
23

Avaliação da resistência à corrosão de titânio comercialmente puro submetido à desinfecção química e polarização em salivas artificiais com diferentes pHs / Evaluation of corrosion resistance of commercially pure titanium submitted to chemical disinfection and polarization in artificialsalivas with different pHs

Raimundo, Lariça Barbosa 26 August 2010 (has links)
O objetivo desse estudo foi avaliar a ação de hipoclorito de sódio e ácido peracético na resistência à corrosão de titânio comercialmente puro, grau 4, (Ticp-4) em salivas artificiais, ácida e neutra, com diferentes períodos de imersão, por meio de ensaio de polarização potenciodinâmica anódica, microscopia eletrônica de varredura e espectrometria dispersiva de raios-X. Corpos-de-prova cilíndricos (5 mm x 5 mm) de Ticp-4 foram envolvidos com fio de cobre e fita isolante, este conjunto foi incluído em tubos de PVC (25 mm x 15 mm) e preenchidos com resina poliéster quimicamente ativada, após a polimerização da resina esses eletrodos de trabalho que foram polidos mecanicamente com lixas, feltros e pastas. Os 54 eletrodos de trabalho foram divididos em nove grupos (n=6) referentes às soluções e períodos de imersão: água destilada (controle), hipoclorito de sódio 1% (10 e 40 minutos), ácido peracético 0,2% (10, 30, 40 e 120 minutos) e ácido peracético 2% (30 e 120 minutos). Após serem imersos nas soluções, foram divididos em 2 subgrupos (n=3), pois os ensaios de polarização anódica foram realizados em triplicatas e utilizados dois eletrólitos, salivas artificiais pH 4,8 e pH 6,8. No ensaio de polarização anódica foi utilizada uma célula eletroquímica constituída por um eletrodo de referência do tipo calomelano saturado (ECS), um contra-eletrodo de platina e o eletrodo de trabalho constituído pelas amostras de Ticp-4, com taxa de varredura de 1 mV/s, partindo-se do potencial de corrosão (Ecorr) até 800 mVECS. Os dados do potencial de corrosão (Ecorr) e corrente de passivação (Ipass) obtidos das curvas de polarização foram analisados estatisticamente pelo teste t Student. Na comparação entre salivas ácida e neutra os valores de Ecorr e Ipass em todas soluções desinfetantes e períodos propostos não apresentaram diferença estatísitica. A comparação dos valores de Ecorr e Ipass entre água destilada (controle) e soluções desinfetantes em saliva ácida também não mostrou diferença, porém em saliva neutra houve diferença entre os valores de Ipass entre água destilada e hipoclorito de sódio 1% por 40 minutos e entre os valores de Ecorr entre água destilada e ácido peracético 2% por 120 minutos. Entre períodos de imersão, em saliva ácida, houve diferença entre os valores de Ipass do hipoclorito de sódio 1% 10 e 40 minutos e entre os valores de Ecorr do ácido peracético 0,2%. A microscopia eletrônica de varredura associada à energia dispersiva por Raio-X não mostrou diferença entre água destilada e as diferentes soluções desinfetantes frente as salivas ácida e neutra. Conclui-se que as curvas de polarização anódica foram similares em todos os ensaios, apesar das diferenças estatísticas salientadas para Ipass e Ecorr, não ocorreu corrosão superficial em quaisquer amostras após desinfecção e polarização em salivas ácida e neutra. A análise por microscopia eletrônica de varredura associada à espectrometria por dissolução de raios-X não revelaram alterações superficiais nas amostras de titânio comercialmente puro. / This study aimed to assess the corrosion resistance in a grade-4 commercially pure titanium (CP Ti-4) under action of sodium hypochlorite or peracetic acid, during different immersion periods, in acid or neutral artificial saliva for anodic potentiodynamic polarization test. Scanning Electron Microscopy (SEM) was used in conjunction with Energy Dispersive X-Ray Spectroscopy (EDS). This study aimed to assess the corrosion resistance in a grade-4 commercially pure titanium (CP Ti-4) under action of sodium hypochlorite or peracetic acid, during different immersion periods, in acid or neutral artificial saliva for anodic potentiodynamic polarization test. Scanning Electron Microscopy (SEM) was used in conjunction with Energy Dispersive X-Ray Spectroscopy (EDS). Cylindrical CP Ti-4 specimens (5 mm x 5 mm) were involved with copper wire and electrical tape, this set was enclosed in PVC pipe (25 mm x 15 mm) and filled with chemically activated polyester resin to obtain the fifty-four working electrodes which were, then, mechanically polished with sandpaper, felt and polishing paste. The 54 working electrodes were divided into nine groups (n = 6) for solutions and immersion periods: distilled water (control), sodium hypochlorite 1% (10 and 40 minutes), peracetic acid 0.2% ( 10, 30, 40 and 120 minutes) and 2% peracetic acid (30 and 120 minutes). After being immersed in the solutions, they were divided into two subgroups (n = 3), because the anodic polarization tests were performed in triplicate and two electrolytes were used: artificial saliva pH 4.8 and pH 6.8. A saturated calomel electrode (SCE) was used as a reference electrochemical electrode for the anodic polarization test with a platinum counter electrode and a working electrode consisting of CP Ti-4 samples with a 1 mV/s scan rate , starting from the corrosion potential (Ecorr) to 800 mVECS. Data for corrosion potential (Ecorr) and for passive current (Ipass) obtatined from the polarization curves were statistically analyzed by Students t-test. When comparing the Ecorr and Ipass values for acid and neutral saliva and disinfectant solutions during all the periods the statistics presented no difference. The comparison of Ecorr and Ipass values between distilled water (control) and disinfecting solutions in acid saliva also showed no difference, but in neutral saliva there was difference for the values of Ipass between distilled water and 1% sodium hypochlorite for 40 minutes and for the values of Ecorr between distilled water and 2% peracetic acid for 120 minutes. When comparing immersion periods, the acid saliva showed different Ipass values for 1% sodium hypochlorite in 10 and 40 minutes and between the Ecorr values for 0.2% peracetic acid. The scanning electron microscopy associated with Energy Dispersive X-Ray Spectroscopy showed no difference between distilled water and the different disinfectant solutions when in acid or neutral saliva. It is concluded that the polarization anodic curves for both acid and neutral saliva were similar in all trials, despite the statistical differences highlighted for Ipass and Ecorr, surface corrosion did not occur in any samples after disinfection and polarization in acidic and neutral saliva. Analysis by Scanning Electron Microscopy associated with Energy Dispersive X-Ray Spectroscopy revealed no surface changes in the commercially pure titanium samples studied.
24

Estudo da atuação e sinergismo de inibidores de corrosão para o aço inoxidável austenítico 304 em meio de ácido peracético comercial 0,2% / Study of the effect and synergism between corrosion inhibitors over the 304 austenitic stainless steel in 0,2% commercial peracetic acid media

Machado, Pedro Alves 11 June 2014 (has links)
O ser humano tem uma grande necessidade de se proteger de fontes de contaminação microbianas. Para tal, ao longo da história, diversos meios foram empregados, desde lavagem com água corrente até as mais modernas substâncias esterilizantes. Entre essas, o ácido peracético (APA) é o mais seguro, sob o ponto de vista ambiental, além de não ser cancerígeno ou tóxico para o corpo humano. O maior empecilho para a aplicação do APA em certas superfícies é seu caráter fortemente oxidante, que pode causar danos em materiais metálicos. Para que tal aplicação seja viável, é necessária a aplicação de inibidores de corrosão que reduzam os danos que o APA possa causar. Para tanto, foram estudadas sete substâncias empregadas comercialmente como inibidores de corrosão para aço inoxidável 304 em meio de ácido peracético a temperatura ambiente: benzotriazol (BTAH), molibdato de sódio, tungstato de sódio, fosfato monossódico, fosfato dissódico, hexametafosfato de sódio e dodecilsulfato de sódio (SDS) e, posteriormente, sinergismos entre os mesmos. Seus desempenhos foram estudados por diferentes técnicas eletroquímicas: potencial de circuito aberto, polarização linear potenciodinâmica, cronoamperometria, espectroscopia de impedância eletroquímica. A superfície do aço foi estudada por microscopia eletrônica de varredura (MEV). As técnicas eletroquímicas demonstraram que o aço 304 encontra-se passivado em meio de ácido peracético 0,2%. Sua resistência à corrosão pode ser significativamente aumentada com o emprego de BTAH, e de sua mistura com SDS, chegando a uma eficiência inibidora de 70%. Os outros inibidores ou pares de inibidores estudados apresentaram eficiências mais baixas. Ensaios microbiológicos foram realizados com o objetivo de se determinar se os inibidores de corrosão poderiam interferir no desempenho do APA como esterilizante. Os resultados obtidos comprovaram que a presença dos inibidores de corrosão BTAH e SDS não interfere sobre a ação esterilizante do APA. / The humanity has a great need to protect itself from microbial contamination. For that, through the history, several ways were employed, since running water washing until the most modern sterilizing substances. Between those, the peracetic acid (PAA) is the safest, under an environmentalist view, besides not being carcinogenic nor toxic to the human body. The great trouble to the application of PAA in some surfaces is its high oxidative property, which can cause damage to metallic materials. Therefore the application of corrosion inhibitor is necessary to reduces the damage that PAA might cause. For that, seven substances commercially applied as corrosion inhibitors for the 304 stainless steel in peracetic acid media were studied: benzotriazole (BTAH), sodium molybdate, sodium tungstate, monosodic phosphate, disodic phosphate, sodium hexametaphophate and sodium dodecilsulphate, as well as the synergism between them. Their per formances were studied through several electrochemical techniques: open circuit potential, linear polarization, chronoamperometry and electrochemical impedance spectroscopy. The steel surfaces were studied through scanning electronic microscopy (SEM). The electrochemical techniques showed that the 304 stainless steel presents passive behavior in 0.2% PAA media. Its corrosion resistance can be significantly improved through the application of BTAH alone, and in combination with SDS, achieving 70% of inhibitor efficiency. The other inhibitors and mixtures studied presented lower efficiency. Microbiological studies were performed aiming to define if the corrosion inhibitor could interfere with the PAA sterilizing performance. The results proved that the presence of BTAH and SDS corrosion inhibitors did not interfere with the sterilizing properties of PAA.
25

Avaliação da resistência à corrosão de titânio comercialmente puro submetido à desinfecção química e polarização em salivas artificiais com diferentes pHs / Evaluation of corrosion resistance of commercially pure titanium submitted to chemical disinfection and polarization in artificialsalivas with different pHs

Lariça Barbosa Raimundo 26 August 2010 (has links)
O objetivo desse estudo foi avaliar a ação de hipoclorito de sódio e ácido peracético na resistência à corrosão de titânio comercialmente puro, grau 4, (Ticp-4) em salivas artificiais, ácida e neutra, com diferentes períodos de imersão, por meio de ensaio de polarização potenciodinâmica anódica, microscopia eletrônica de varredura e espectrometria dispersiva de raios-X. Corpos-de-prova cilíndricos (5 mm x 5 mm) de Ticp-4 foram envolvidos com fio de cobre e fita isolante, este conjunto foi incluído em tubos de PVC (25 mm x 15 mm) e preenchidos com resina poliéster quimicamente ativada, após a polimerização da resina esses eletrodos de trabalho que foram polidos mecanicamente com lixas, feltros e pastas. Os 54 eletrodos de trabalho foram divididos em nove grupos (n=6) referentes às soluções e períodos de imersão: água destilada (controle), hipoclorito de sódio 1% (10 e 40 minutos), ácido peracético 0,2% (10, 30, 40 e 120 minutos) e ácido peracético 2% (30 e 120 minutos). Após serem imersos nas soluções, foram divididos em 2 subgrupos (n=3), pois os ensaios de polarização anódica foram realizados em triplicatas e utilizados dois eletrólitos, salivas artificiais pH 4,8 e pH 6,8. No ensaio de polarização anódica foi utilizada uma célula eletroquímica constituída por um eletrodo de referência do tipo calomelano saturado (ECS), um contra-eletrodo de platina e o eletrodo de trabalho constituído pelas amostras de Ticp-4, com taxa de varredura de 1 mV/s, partindo-se do potencial de corrosão (Ecorr) até 800 mVECS. Os dados do potencial de corrosão (Ecorr) e corrente de passivação (Ipass) obtidos das curvas de polarização foram analisados estatisticamente pelo teste t Student. Na comparação entre salivas ácida e neutra os valores de Ecorr e Ipass em todas soluções desinfetantes e períodos propostos não apresentaram diferença estatísitica. A comparação dos valores de Ecorr e Ipass entre água destilada (controle) e soluções desinfetantes em saliva ácida também não mostrou diferença, porém em saliva neutra houve diferença entre os valores de Ipass entre água destilada e hipoclorito de sódio 1% por 40 minutos e entre os valores de Ecorr entre água destilada e ácido peracético 2% por 120 minutos. Entre períodos de imersão, em saliva ácida, houve diferença entre os valores de Ipass do hipoclorito de sódio 1% 10 e 40 minutos e entre os valores de Ecorr do ácido peracético 0,2%. A microscopia eletrônica de varredura associada à energia dispersiva por Raio-X não mostrou diferença entre água destilada e as diferentes soluções desinfetantes frente as salivas ácida e neutra. Conclui-se que as curvas de polarização anódica foram similares em todos os ensaios, apesar das diferenças estatísticas salientadas para Ipass e Ecorr, não ocorreu corrosão superficial em quaisquer amostras após desinfecção e polarização em salivas ácida e neutra. A análise por microscopia eletrônica de varredura associada à espectrometria por dissolução de raios-X não revelaram alterações superficiais nas amostras de titânio comercialmente puro. / This study aimed to assess the corrosion resistance in a grade-4 commercially pure titanium (CP Ti-4) under action of sodium hypochlorite or peracetic acid, during different immersion periods, in acid or neutral artificial saliva for anodic potentiodynamic polarization test. Scanning Electron Microscopy (SEM) was used in conjunction with Energy Dispersive X-Ray Spectroscopy (EDS). This study aimed to assess the corrosion resistance in a grade-4 commercially pure titanium (CP Ti-4) under action of sodium hypochlorite or peracetic acid, during different immersion periods, in acid or neutral artificial saliva for anodic potentiodynamic polarization test. Scanning Electron Microscopy (SEM) was used in conjunction with Energy Dispersive X-Ray Spectroscopy (EDS). Cylindrical CP Ti-4 specimens (5 mm x 5 mm) were involved with copper wire and electrical tape, this set was enclosed in PVC pipe (25 mm x 15 mm) and filled with chemically activated polyester resin to obtain the fifty-four working electrodes which were, then, mechanically polished with sandpaper, felt and polishing paste. The 54 working electrodes were divided into nine groups (n = 6) for solutions and immersion periods: distilled water (control), sodium hypochlorite 1% (10 and 40 minutes), peracetic acid 0.2% ( 10, 30, 40 and 120 minutes) and 2% peracetic acid (30 and 120 minutes). After being immersed in the solutions, they were divided into two subgroups (n = 3), because the anodic polarization tests were performed in triplicate and two electrolytes were used: artificial saliva pH 4.8 and pH 6.8. A saturated calomel electrode (SCE) was used as a reference electrochemical electrode for the anodic polarization test with a platinum counter electrode and a working electrode consisting of CP Ti-4 samples with a 1 mV/s scan rate , starting from the corrosion potential (Ecorr) to 800 mVECS. Data for corrosion potential (Ecorr) and for passive current (Ipass) obtatined from the polarization curves were statistically analyzed by Students t-test. When comparing the Ecorr and Ipass values for acid and neutral saliva and disinfectant solutions during all the periods the statistics presented no difference. The comparison of Ecorr and Ipass values between distilled water (control) and disinfecting solutions in acid saliva also showed no difference, but in neutral saliva there was difference for the values of Ipass between distilled water and 1% sodium hypochlorite for 40 minutes and for the values of Ecorr between distilled water and 2% peracetic acid for 120 minutes. When comparing immersion periods, the acid saliva showed different Ipass values for 1% sodium hypochlorite in 10 and 40 minutes and between the Ecorr values for 0.2% peracetic acid. The scanning electron microscopy associated with Energy Dispersive X-Ray Spectroscopy showed no difference between distilled water and the different disinfectant solutions when in acid or neutral saliva. It is concluded that the polarization anodic curves for both acid and neutral saliva were similar in all trials, despite the statistical differences highlighted for Ipass and Ecorr, surface corrosion did not occur in any samples after disinfection and polarization in acidic and neutral saliva. Analysis by Scanning Electron Microscopy associated with Energy Dispersive X-Ray Spectroscopy revealed no surface changes in the commercially pure titanium samples studied.
26

ESTUDO DO ÁCIDO PERACÉTICO NA DESINFECÇÃO DE ESGOTO SANITÁRIO: INFLUÊNCIA DAS CARACTERÍSTICAS FÍSICO-QUÍMICAS DO EFLUENTE, DETERMINAÇÃO DE CONCENTRAÇÃO RESIDUAL E CINÉTICA DE DEGRADAÇÃO

Cavallini, Grasiele Soares 17 June 2011 (has links)
Made available in DSpace on 2017-07-24T19:38:05Z (GMT). No. of bitstreams: 1 Grasiele Cavallini.pdf: 1079338 bytes, checksum: 72df0086e3189309ac759c245ed41fed (MD5) Previous issue date: 2011-06-17 / This work aims to study the use of peracetic acid (PAA) to disinfect wastewater. Into this perspective, some methods were investigated to determine residual PAA, factors that interfere with its disinfecting action, its kinetic of degradation in wastewater and some possible by-products coming from its application. The results showed that the concentrations between 0,5 and 10 mg/L of PAA could be determined as for cerimetric/iodometric method as for spectrofotometric method using cromophore DPD. To concentrations between 01 and 05 mg/L only the method with DPD could be recommended. The disinfection tests with PAA demonstrated the grades of SST larger than 50mg/L implicated in an increase of 50% in disinfectant consume to inactivate total coliforms microorganisms and E.coli. The efficiency to inactivation of PAA related to the E.coli was also damaged in conditions of pH larger than 8. The time of contact had major influence in disinfection efficiency in dose up to 5mg/L of PAA. The kinetic tests showed that the degradation of PAA, about the studied wastewater, could be represented for a reaction of first order and its time of half-life in the wastewater was estimated in 79 minutes. The formation of by-products: nonanal, decanal, chlorophenols and 1-metoxi-4-methylbenzene weren’t observed in the wastewater, using the PAA dose of 10mg/L. With this same dose the physicochemical conditions like pH, BOD and COD of wastewater didn’t suffer prominent variation, however the DO got a larger increase of 60%, being this one of the most significant physicochemical contributions. Thus, the results with application of PAA indicated that its use in doses up to 10mg/L contributed to inactivate microorganisms and not altered significantly initial conditions of wastewater and there weren’t environmental damages demonstrated about the studied parameters. / Este trabalho tem por objetivo estudar a utilização do ácido peracético (APA) na desinfecção de efluentes sanitários. Dentro desta perspectiva foram investigados: métodos para determinação do APA residual, os fatores que interferem na sua ação desinfetante, sua cinética de degradação no efluente e alguns possíveis subprodutos provenientes da sua aplicação. Os resultados obtidos demonstraram que as concentrações entre 0,5 e 10 mg/L de APA puderam ser determinadas tanto pelo método cerimétrico/iodométrico como pelo método espectrofotométrico utilizando o cromóforo DPD. Para concentrações entre 0,1 e 0,5 mg/L apenas o método com DPD pôde ser recomendado. Os ensaios de desinfecção com APA demonstraram que teores de SST superiores a 50 mg/L implicaram em um aumento de 50% no consumo do desinfetante para inativação dos microrganismos coliformes totais e E. coli. A eficiência de inativação do APA em relação a E. coli também foi prejudicada em condições de pH superiores a 8. O tempo de contato teve maior influência na eficiência de desinfecção em dosagens até 5 mg/L de APA. Os ensaios cinéticos demonstraram que a degradação do APA, no efluente em estudo, pôde ser representada por uma reação de primeira ordem e seu tempo de meia-vida no efluente foi estimado em 79 minutos. A formação dos subprodutos: nonanal, decanal, clorofenóis e 1-metoxi-4-metilbenzeno não foram observadas no efluente, utilizando a dosagem de 10 mg/L de APA. Com esta mesma dosagem as condições físico-químicas, como pH, DBO e DQO do efluente não sofreram acentuada variação, porém o OD obteve um aumento superior a 60%, sendo esta uma das contribuições físico-químicas mais significativas. Assim, os resultados obtidos com a aplicação do APA indicaram que sua utilização em dosagens até 10 mg/L contribuíram para inativação de microrganismos e não alteraram de forma significativa as condições iniciais do efluente, além de não ter demonstrado prejuízos ambientais nos parâmetros estudados.
27

\'Listeria monocytogenes\' em alimentos fatiados e equipamentos: ocorrência, formação de biofilme e controle / Listeria monocytogenes in sliced foods and equipments: occurrence, biofilm formation and control

Ratti, Regiane Priscila 03 July 2006 (has links)
Listeria monocytogenes é o agente causal da listeriose, uma doença que pode atingir mulheres grávidas (e seus fetos), crianças, idosos e indivíduos com o sistema imunológico comprometido, A listeriose representa a maioria dos casos de morte decorrente de toxinfecções alimentares. Os alimentos são reconhecidos como fontes primárias da transmissão desta bactéria para o homem e L. monocytogenes já foi isolada de uma grande variedade de alimentos. Superfícies de equipamentos utilizados na produção de alimentos também podem estar contaminadas com este patógeno. Falhas em procedimentos de higienização podem deixar resíduos nos equipamentos de processamento de alimentos e L. monocytogenes pode se aderir a superfícies abióticas e iniciar sua multiplicação, dando origem a biofilmes. A interação com bactérias de outras espécies pode influenciar na forma formação de biofilmes por L. monocytogenes, constituindo um aspecto importante de estudo para auxiliar no controle da contaminação de alimentos por esta bactéria. Leuconostoc mesenteroides é uma bactéria lática normalmente encontrada em alimentos e algumas cepas podem interferir na multiplicação de L. monocytogenes pela produção de bacteriocinas com atividade antilisterial. Os biofilmes representam uma preocupação para indústria de alimentos, pois geralmente os microorganismos aderidos apresentam maior capacidade de resistir a tratamentos antimicrobianos. Neste trabalho, foram coletadas 30 amostras de presunto cozido fatiado, 30 de mussarela fatiada e 30 de superfícies de equipamentos de fatiar alimentos, em estabelecimentos do comércio varejista de Ribeirão Preto SP. As amostras forma avaliadas quanto à presença ou ausência de L. monocytogenes e também foi estudada a capacidade dos isolados em formar biofilmes em cultura pura e em testes de co-cultura. O sanitizante ácido peracético e a bacteriocina nisina foram testados para controlar a formação de biofilme por L. monocytogenes. Os resultados obtidos mostram que os isolados de L. monocytogenes formaram biofilme em superfície de aço inoxidável quando cultivados isoladamente ou em testes de co-cultura com L.mesenteroides. O tratamento da lâmina com ácido peracético inativou todas as células presentes no biofilme. Nas condições utilizadas, nisina não apresentou atividade contra L.monocytogenes em biofilmes. / Listeria monocytogenes is the causal agent of listeriosis, an infection that targets mainly pregnant women (and their fetuses), children, the elderly and immunocompromised individuals. Listeriosis represents the majority of fatal cases of foodborne diseases. Foods are recognized as primary sources of transmission of this bacterium to man and L. monocytogenes has been isolated from of a great variety of foods. Surfaces of equipments used in the production of foods can harbour L. monocytogenes. Failures in sanitization procedures can leave food residues adhered to equipments of food processing and L. monocytogenes can attach to abiotic surfaces, multiply and form biofilms. Interactions among bacteria of diverse species may influence biofilm formation by L. monocytogenes and this is an important issue to be studied to improve food safety. Leuconostoc mesenteroides is a lactic bacterium usually found in foods and some strains can interfere with the multiplication of L. monocytogenes by production of bacteriocins with antilisterial activity. Biofilms represent a special concern to the food industry, because adhered microorganism are generally more resistant to antimicrobial treatments. In this work, we collected 30 samples of sliced cooked ham, 30 of sliced mozzarella cheese and 30 of surfaces of food processing equipments, in the retail market of the city of Ribeirão Preto - SP. The samples were studied for presence or absence of L. monocytogenes. The ability of the isolates to form biofilms was also studied, in pure and in co-culture tests. The sanitizer peracetic acid and the bacteriocin nisin were tested to control biofilm formation by L. monocytogenes. L. monocytogenes formed biofilm on stainless steel coupons when cultivated alone or in co-culture with L. mesenteroides. The treatment of stainless steel coupons with peracetic acid inactivated the cells of the biofilm. Under the experimental conditions tested nisin did not present activity against L. monocytogenes in biofilms.
28

Estudo da atuação e sinergismo de inibidores de corrosão para o aço inoxidável austenítico 304 em meio de ácido peracético comercial 0,2% / Study of the effect and synergism between corrosion inhibitors over the 304 austenitic stainless steel in 0,2% commercial peracetic acid media

Pedro Alves Machado 11 June 2014 (has links)
O ser humano tem uma grande necessidade de se proteger de fontes de contaminação microbianas. Para tal, ao longo da história, diversos meios foram empregados, desde lavagem com água corrente até as mais modernas substâncias esterilizantes. Entre essas, o ácido peracético (APA) é o mais seguro, sob o ponto de vista ambiental, além de não ser cancerígeno ou tóxico para o corpo humano. O maior empecilho para a aplicação do APA em certas superfícies é seu caráter fortemente oxidante, que pode causar danos em materiais metálicos. Para que tal aplicação seja viável, é necessária a aplicação de inibidores de corrosão que reduzam os danos que o APA possa causar. Para tanto, foram estudadas sete substâncias empregadas comercialmente como inibidores de corrosão para aço inoxidável 304 em meio de ácido peracético a temperatura ambiente: benzotriazol (BTAH), molibdato de sódio, tungstato de sódio, fosfato monossódico, fosfato dissódico, hexametafosfato de sódio e dodecilsulfato de sódio (SDS) e, posteriormente, sinergismos entre os mesmos. Seus desempenhos foram estudados por diferentes técnicas eletroquímicas: potencial de circuito aberto, polarização linear potenciodinâmica, cronoamperometria, espectroscopia de impedância eletroquímica. A superfície do aço foi estudada por microscopia eletrônica de varredura (MEV). As técnicas eletroquímicas demonstraram que o aço 304 encontra-se passivado em meio de ácido peracético 0,2%. Sua resistência à corrosão pode ser significativamente aumentada com o emprego de BTAH, e de sua mistura com SDS, chegando a uma eficiência inibidora de 70%. Os outros inibidores ou pares de inibidores estudados apresentaram eficiências mais baixas. Ensaios microbiológicos foram realizados com o objetivo de se determinar se os inibidores de corrosão poderiam interferir no desempenho do APA como esterilizante. Os resultados obtidos comprovaram que a presença dos inibidores de corrosão BTAH e SDS não interfere sobre a ação esterilizante do APA. / The humanity has a great need to protect itself from microbial contamination. For that, through the history, several ways were employed, since running water washing until the most modern sterilizing substances. Between those, the peracetic acid (PAA) is the safest, under an environmentalist view, besides not being carcinogenic nor toxic to the human body. The great trouble to the application of PAA in some surfaces is its high oxidative property, which can cause damage to metallic materials. Therefore the application of corrosion inhibitor is necessary to reduces the damage that PAA might cause. For that, seven substances commercially applied as corrosion inhibitors for the 304 stainless steel in peracetic acid media were studied: benzotriazole (BTAH), sodium molybdate, sodium tungstate, monosodic phosphate, disodic phosphate, sodium hexametaphophate and sodium dodecilsulphate, as well as the synergism between them. Their per formances were studied through several electrochemical techniques: open circuit potential, linear polarization, chronoamperometry and electrochemical impedance spectroscopy. The steel surfaces were studied through scanning electronic microscopy (SEM). The electrochemical techniques showed that the 304 stainless steel presents passive behavior in 0.2% PAA media. Its corrosion resistance can be significantly improved through the application of BTAH alone, and in combination with SDS, achieving 70% of inhibitor efficiency. The other inhibitors and mixtures studied presented lower efficiency. Microbiological studies were performed aiming to define if the corrosion inhibitor could interfere with the PAA sterilizing performance. The results proved that the presence of BTAH and SDS corrosion inhibitors did not interfere with the sterilizing properties of PAA.
29

\'Listeria monocytogenes\' em alimentos fatiados e equipamentos: ocorrência, formação de biofilme e controle / Listeria monocytogenes in sliced foods and equipments: occurrence, biofilm formation and control

Regiane Priscila Ratti 03 July 2006 (has links)
Listeria monocytogenes é o agente causal da listeriose, uma doença que pode atingir mulheres grávidas (e seus fetos), crianças, idosos e indivíduos com o sistema imunológico comprometido, A listeriose representa a maioria dos casos de morte decorrente de toxinfecções alimentares. Os alimentos são reconhecidos como fontes primárias da transmissão desta bactéria para o homem e L. monocytogenes já foi isolada de uma grande variedade de alimentos. Superfícies de equipamentos utilizados na produção de alimentos também podem estar contaminadas com este patógeno. Falhas em procedimentos de higienização podem deixar resíduos nos equipamentos de processamento de alimentos e L. monocytogenes pode se aderir a superfícies abióticas e iniciar sua multiplicação, dando origem a biofilmes. A interação com bactérias de outras espécies pode influenciar na forma formação de biofilmes por L. monocytogenes, constituindo um aspecto importante de estudo para auxiliar no controle da contaminação de alimentos por esta bactéria. Leuconostoc mesenteroides é uma bactéria lática normalmente encontrada em alimentos e algumas cepas podem interferir na multiplicação de L. monocytogenes pela produção de bacteriocinas com atividade antilisterial. Os biofilmes representam uma preocupação para indústria de alimentos, pois geralmente os microorganismos aderidos apresentam maior capacidade de resistir a tratamentos antimicrobianos. Neste trabalho, foram coletadas 30 amostras de presunto cozido fatiado, 30 de mussarela fatiada e 30 de superfícies de equipamentos de fatiar alimentos, em estabelecimentos do comércio varejista de Ribeirão Preto SP. As amostras forma avaliadas quanto à presença ou ausência de L. monocytogenes e também foi estudada a capacidade dos isolados em formar biofilmes em cultura pura e em testes de co-cultura. O sanitizante ácido peracético e a bacteriocina nisina foram testados para controlar a formação de biofilme por L. monocytogenes. Os resultados obtidos mostram que os isolados de L. monocytogenes formaram biofilme em superfície de aço inoxidável quando cultivados isoladamente ou em testes de co-cultura com L.mesenteroides. O tratamento da lâmina com ácido peracético inativou todas as células presentes no biofilme. Nas condições utilizadas, nisina não apresentou atividade contra L.monocytogenes em biofilmes. / Listeria monocytogenes is the causal agent of listeriosis, an infection that targets mainly pregnant women (and their fetuses), children, the elderly and immunocompromised individuals. Listeriosis represents the majority of fatal cases of foodborne diseases. Foods are recognized as primary sources of transmission of this bacterium to man and L. monocytogenes has been isolated from of a great variety of foods. Surfaces of equipments used in the production of foods can harbour L. monocytogenes. Failures in sanitization procedures can leave food residues adhered to equipments of food processing and L. monocytogenes can attach to abiotic surfaces, multiply and form biofilms. Interactions among bacteria of diverse species may influence biofilm formation by L. monocytogenes and this is an important issue to be studied to improve food safety. Leuconostoc mesenteroides is a lactic bacterium usually found in foods and some strains can interfere with the multiplication of L. monocytogenes by production of bacteriocins with antilisterial activity. Biofilms represent a special concern to the food industry, because adhered microorganism are generally more resistant to antimicrobial treatments. In this work, we collected 30 samples of sliced cooked ham, 30 of sliced mozzarella cheese and 30 of surfaces of food processing equipments, in the retail market of the city of Ribeirão Preto - SP. The samples were studied for presence or absence of L. monocytogenes. The ability of the isolates to form biofilms was also studied, in pure and in co-culture tests. The sanitizer peracetic acid and the bacteriocin nisin were tested to control biofilm formation by L. monocytogenes. L. monocytogenes formed biofilm on stainless steel coupons when cultivated alone or in co-culture with L. mesenteroides. The treatment of stainless steel coupons with peracetic acid inactivated the cells of the biofilm. Under the experimental conditions tested nisin did not present activity against L. monocytogenes in biofilms.
30

PÓS-TRATAMENTO DE EFLUENTE DE REATOR ANAERÓBIO UTILIZANDO DUPLA FILTRAÇÃO PARA FINS DE REÚSO

Cavallini, Grasiele Soares 23 October 2015 (has links)
Made available in DSpace on 2017-07-20T12:40:16Z (GMT). No. of bitstreams: 1 Grasiele Cavallini tese.pdf: 2849739 bytes, checksum: 3a66c1a0f56779dc9b4b25e36a7e4b63 (MD5) Previous issue date: 2015-10-23 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This study evaluates the use of a pilot filtering double unit, comprising an ascending draining gravel filter and a rapid descending sand filter for the treatment of UASB reactor effluent. As a preliminary phase to the double filtering, coagulation/oxidation was used aiming at helping degradation and flocculation of contaminants, facilitating their retention on the filters. In this phase, three combinations were used: ferrous sulfate (FS) and peracetic acid (APA); ferrous chloride (FC) and CF and APA, all with the same iron concentration. After treatability tests, the efficacy of the system was assessed through the physical-chemical and microbiological parameters. In all treatments carried out in the pilot unit, the suspended solids (SST) were totally removed, which resulted in over 90% turbidity reduction. The treatments in the presence of APA demonstrated higher removal of the effluent color, however, the treatment with FS and APA cannot be recommended due to the high concentration of sulfate ions in the final effluent. Regarding microbiological parameters, the presence of oxidant contributed to the partial inactivation of microorganisms. The alternative to carry out a disinfection phase with APA after double filtering using the coagulant/oxidant FC/APA can be employed without any addition phase to irrigate orchards, pastures and cereal crops according to the NBR 13969/97. By adding the pH adjustment phase and chloride addition to the treatment proposed, the treated effluent can be reused in: agriculture, restrictive agriculture; damming, restrictive damming, environment, industry and the replenishment of underground water (except for drinking purposes), according to the recommendations of the USEPA (2012) Recommendation Manual. / Este trabalho avalia o uso de uma unidade piloto de dupla filtração, composta por filtro de pedregulho de escoamento ascendente e filtro rápido descendente de areia para pós-tratamento de efluente de reator UASB. Como etapa preliminar à dupla filtração utilizou-se a coagulação/oxidação, com o objetivo de auxiliar na degradação e na floculação dos contaminantes, facilitando sua retenção nos filtros. Nesta etapa foram utilizadas três combinações: Sulfato ferroso (SF) e ácido peracético (APA); Cloreto férrico (CF) e CF e APA, todas com a mesma concentração de ferro. Após os ensaios de tratabilidade a eficiência do sistema foi avaliada através de parâmetros físico-químicos e microbiológicos. Em todos os tratamentos realizados na unidade piloto os sólidos em suspensão (SST) foram totalmente removidos o que refletiu em reduções superiores a 90% de turbidez. Os tratamentos com a presença do oxidante APA demonstraram uma remoção maior da cor do efluente, porém o tratamento com SF e APA não pode ser recomendado pela alta concentração de íons sulfato no efluente final. Quanto aos parâmetros microbiológicos, a presença do oxidante contribuiu para a inativação parcial dos microrganismos. A alternativa de realizar a etapa de desinfecção com APA após a dupla filtração com CF também foi avaliada e possibilitou desinfecção total do efluente quanto aos indicadores de contaminação avaliados. Considerando a possibilidade de reúso, o efluente UASB pós-tratado pela dupla filtração utilizando o coagulante/oxidante CF/APA pode ser utilizado sem nenhuma etapa adicional para irrigação de pomares, pastagens e cultivo de cereais de acordo com a NBR 13969/97. Acrescentando a etapa de ajuste de pH e adição de cloro no tratamento proposto o efluente tratado pode ser utilizado para reúsos: agrícola; agrícola restritivo; represamento; represamento restritivo; ambiental; industrial e reabastecimento de águas subterrâneas (reutilização não potável), de acordo com as recomendações do manual de reúso da USEPA (2012).

Page generated in 0.0581 seconds