Spelling suggestions: "subject:"águas residual purificação"" "subject:"águas residual urificação""
291 |
Estudo da eficiência do processo de coagulação/floculação e do processo combinado de coagulação/floculação/adsorção para tratamento de águas residuárias de galvanoplastia utilizando Moringa oleífera / Study on the efficiency of the process of coagulation/flocculation and the combined process of coagulation/flocculation/adsorption for treatment of electroplating wastewater using Moringa oleiferaAlves, Alvaro Cesar Dias 24 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:07:59Z (GMT). No. of bitstreams: 1
Alvaro Cesar Dias Alves.pdf: 1860253 bytes, checksum: fce25e3199fa4e1f2d24f3500c996153 (MD5)
Previous issue date: 2012-02-24 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This study aimed to evaluate the efficiency of the process of coagulation/ flocculation and coagulation/flocculation/adsorption combined process for treatment of liquid effluent from the electroplanting industry. Were used the moringa seed as a natural coagulant agent and moringa bark and string bean as adsorbents. Were evaluated the parameters COD, color, pH, turbidity and the concentration of metal ions Cr, Zn, Cu and Ni. In the stage of coagulation/ flocculation were used several concentrations of moringa in salt solution of NaCl 1 M and 0.1M. In the stage of the combined adsorbents were used moringa bark and string beans to determine which of the adsorbent had a better removal efficiency of metals. Tests were also conducted with different ranges of mass for the best adsorbent and variation of pH of the studied effluent. Tests of coagulation/flocculation showed good removal efficiency for the parameters COD, Color, Turbidity and the metals Cr, Zn, Cu and Ni using MO seed in salt solution 1M, these values being 90.49%, 78.34%, 95.13%, 25.29%, 84.30%, 51.11% and 24.74% respectively. In the tests of coagulation/flocculation/adsorption the maximum removal efficiencies were 91.41% for COD, 90.77% for color, 95.31% for Turbidity, 58.36% for Cr, 98.36% for Zn, 97,58% for Cu and 99.11% for Ni. The research showed that after the combined process the electroplanting effluent did not present the necessary characteristics for the released in to water bodies due to the high remaining concentration of Cr (1907.4 mg/L), Color (860 PtCo/L) and COD (330 mg/L). The research for the treatment process demonstrated great effectiveness for most parameters analyzed, however, its necessary to study complementary technologies for this type of treatment effluent in order to achieve an effluent within the release standards into the water bodies. / Este trabalho teve como objetivo avaliar a eficiência do processo de coagulação/floculação e do processo combinado de coagulação/floculação/adsorção para tratamento de efluente liquido da indústria galvânica. Foi utilizada a semente de moringa como coagulante natural e a casca e a vagem de moringa como adsorventes. Foram avaliados os parâmetros DQO, Cor, pH, Turbidez e a concentração dos íons metálicos Cr, Zn, Cu e Ni. Na etapa de coagulação/floculação foram utilizadas várias concentrações de moringa em solução salina de NaCl 1M e 0,1M. Na etapa do processo combinado foram utilizados os adsorventes casca e vagem de moringa para determinação do adsorvente com melhor eficiência de remoção dos metais. Também foram realizados ensaios com variação de massa do melhor adsorvente e variação do pH do efluente estudado. Os ensaios de coagulação/floculação mostraram boa eficiência de remoção dos parâmetros DQO, Cor, Turbidez e dos metais Cr, Zn, Cu e Ni utilizando semente de MO em solução salina 1M, sendo esses valores 90,49%, 78,34%, 95,13%, 25,29%, 84,30%, 51,11% e 24,74%, respectivamente. Nos ensaios de coagulação/floculação/adsorção as eficiências máximas de remoção foram 91,41% para DQO, 90,77% para Cor, 95,31% para Turbidez, 58,36% para Cr, 98,36% para Zn, 97,58% para Cu e 99,11% para Ni. Verificou-se que após o processo combinado o efluente galvânico não apresentou as características necessárias para lançamento em corpos hídricos em função da alta concentração remanescente de Cr (1907,4 mg/L), Cor (860 PtCo/L) e DQO (330 mg/L). Verificou-se que os processos de tratamento estudados demonstraram eficiência para a maioria dos parâmetros analisados, entretanto, fazem-se necessários estudar tecnologias complementares para o tratamento deste tipo de efluente com intuito de obter um efluente dentro dos padrões de lançamentos em corpos receptores.
|
292 |
Remoção do corante Azul Reativo 5G utilizando o adsorvente comercial Dowex Optipore SD-2 / Removal of Reactive Blue 5G dye using commercial adsorbent Dowex Optipore SD-2.Oliveira, Silvia Priscila Dias de 21 February 2013 (has links)
Made available in DSpace on 2017-07-10T18:08:03Z (GMT). No. of bitstreams: 1
Silvia P Dias de Oliveira.pdf: 1230611 bytes, checksum: a3c50b4c24862ccdb82c63279b67c320 (MD5)
Previous issue date: 2013-02-21 / Fundação Araucária / In this work, removal of Reactive Blue 5G dye using a commercial Dowex Optipore SD-2 adsorbent was investigated regarding variations on pH (1-12), temperature (20-50oC) and shaking (90-200 rpm) values in order to establish best adsorption conditions. The point of zero charge (pcz) was determined varying solution pH from 2 to 12 and defining the pH range where the adsorbent surface is electrically neutral. Batch kinetic experiments at pH 2 consisting on a mixture of 5 mg adsorbent and 50 mL dye solution (150 mgL-1) were performed considering four temperatures (20, 30, 40 and 50°C), under 120 rpm shaking. Regarding temperature of 30°C and shaking of 120 rpm as suitable to improve the removal of Dowex Optipore SD-2 adsorbent, batch equilibrium adsorption experiments were carried out at pH values ranging from 1 to 12 and considering dye solutions with concentration varying from 5 to 300 mg L-1. From pcz results, pH values between 4 and 10 have evidenced electrically neutral behavior on adsorbent surface. Adsorption kinetic data were interpreted according to film diffusion, superficial adsorption and pores diffusion kinetic models. Six isotherm models such as Langmuir, Freundlich and Temkin were used to describe the equilibrium data, being the Langmuir isotherm fitted better to the data with a maximum adsorption capacity (qmax) of 315 mg L-1. Performing a comparison with other adsorbents, such as orange peel, macrophyte Egeria Densa, eggshell and activated charcoal reported in literature for reactive dye removal, the Dowex Optipore SD-2 adsorbent exhibits greater adsorption capacity than the other ones, being more effective for reactive dye removal, but with a slow kinetic response. / O objetivo principal deste trabalho foi estudar a remoção do corante Azul Reativo 5G utilizando o adsorvente comercial Dowex Optipore SD-2. Foram realizados testes preliminares em sistema fechado e batelada variando o pH de 1 a 12, a temperatura de 20 a 50°C e a velocidade de agitação de 90 a 200 rpm. O ponto de carga zero (pHpcz) do adsorvente foi obtido a partir do método da titulação potenciométrica. O teste cinético foi conduzido em sistema fechado e batelada, misturando 5 mg de adsorvente com 50 mL de solução de corante (150 mg L-1), com pH 2, em quatro temperaturas (20, 30, 40 e 50°C)sob agitação constante de 120 rpm. O teste de equilíbrio foi realizado para pHs entre 1 e 12 e a concentração da solução de corante variando de 5 a 300 mg L-1, neste teste a temperatura e a velocidade de agitação foram fixadas em 30°C e 120 rpm, respectivamente. A partir da análise do pHpcz observou-se que para valores de pH entre 4 e 10 a carga superficial líquida do adsorvente é nula. A cinética de adsorção foi descrita por três modelos matemáticos: difusão no filme, adsorção na superfície e difusão nos poros. Seis modelos de isoterma, dentre eles Langmuir, Freundlich e Temkin foram utilizados para descrever dos dados de equilíbrio, sendo que Langmuir foi o que melhor se ajustou aos dados experimentais de equilíbrio. O adsorvente apresentou uma capacidade máxima de adsorção (qmax) de 315 mg L-1. Comparando com outros adsorventes, tais como bagaço de laranja, Macrófita Egeria Densa, casca de ovo e carvão ativado, encontrados na literatura para a remoção de corantes reativos, o adsorvente Dowex Optipore SD-2 apresenta capacidade máxima de adsorção muito superior aos demais adsorventes, sendo mais efetivo na remoção de corante reativo, no entanto apresenta uma cinética lenta.
|
293 |
Aplicação da técnica de eletro-floculação no tratamento de efluentes de curtume / Application of electroflocculation technique for the tannery effluent treatmentFornari, Marilda Menchon Tavares 12 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:07Z (GMT). No. of bitstreams: 1
Marilda M T Fornari.pdf: 813038 bytes, checksum: 1672b5ca9a95a70d2125540cf442fb8a (MD5)
Previous issue date: 2008-02-12 / In the present work has been studied the electro-flocculation efficiency on the reduction of organic and inorganic material concentrations such as Chemical Oxygen Demand (COD), turbidity, total solids and metal, mainly chromium, on an untreated tannery effluent using a pair of electrodes. For this purpose, a lab scale Electro-Flocculation (EF) reactor was constructed using an 8-L plastic cylindrical container, containing a valve in its lower part for sludge evacuation and a horizontal support in its upper part for fixing a pair of electrolytic cell in upright position into a 5-L available reactor volume. The electrodes plates, made of iron or aluminum, were connected to terminals of direct current power supply.
All the physical-chemistry parameters were measured following the Standard Methods for water analysis, while metal concentrations were determined using the Synchrotron X-Ray Fluorescence technique, available in the Brazilian Synchrotron Light Laboratory. In order to determine optimal operating conditions, the effects of current intensity, electrodes distance, effluent initial pH, and EF time have been experimentally examined, according to a statistic planning and correlation analysis. For each electrode, a total of 11 EF experiments were carried out for maximum and minimum values of EF reactor operating parameters. Applying a 95% confidence level into the correlation analysis between EF parameters, the physical-chemistry parameters and metal concentrations were reduced in all of them when the effluent initial pH was increased, while the EF time and the applied voltage were reduced for small electrodes distances. Moreover, the EF treatment efficiencies tend towards higher values with an increasing on the current intensity. In order to determine the best reactor operating values, other EF experiments were performed varying the effluent initial pH from 6.5 to 9.0 and from 6.0 to 8.5 for iron and aluminum electrodes, respectively, fixing the distance between the electrodes in 4.0 cm, the current intensity in 5.5 A and the EF time in 30 minutes. Nevertheless, these EF experiments have shown that the reduction factor on parameter concentrations due to an increasing of effluent initial pH was not significant compared to prior experiments. Henceforth, the effluent pH value was maintained near to the original one for the next EF treatments, avoiding introducing other substances into the effluent.
Keeping effluent pH value in 7.5, other EF experiments were performed changing the EF time from 15 to 120 min., fixing current intensities and electrode distances in 5.5 A and 4.0 cm, respectively. For these reactor conditions, the EF time setting up in 30 min. was enough to get a good efficiency according the reduction factor in the most of parameters examined, without increasing a lot the reactor electrical power, for both kinds of electrodes. The EF reactor purpose and examined has shown a high efficiency on turbidity and chromium concentration reduction factor (98%). Furthermore, this system can be also used to reduce other elementary concentrations such as calcium, potassium and zinc, for both kinds of electrodes (Fe/Al). In comparison with iron electrodes, aluminum one has reported a better reduction factor (80%) on COD values and a good reduction factor (50%) on iron concentration. On the other hand, the EF method for tanneries effluent treatment system was also compared with conventional method using coagulating and flocculating agents, showing a great similarity between them in the reduction factor. In the EF method is not necessary to introduce substances to start the coagulation and flocculation process in effluent treatment. / Este trabalho tem por objetivo o estudo da eficiência da eletro-floculação na redução das concentrações de substâncias orgânicas e inorgânicas expressas através dos parâmetros: Demanda Química de Oxigênio (DQO), turbidez, sólidos totais e metais, principalmente o cromo, em efluente de curtume não tratado, utilizando um par de eletrodos. Para esse propósito foi construído, em escala laboratorial, um reator confeccionado a partir de um recipiente plástico de 8 litros, contendo uma válvula na parte inferior, para a retirada dos sedimentos, e um suporte horizontal na parte superior para a fixação do par de células eletrolíticas, em posição perpendicular dentro do reator com volume útil de 5 litros. As placas de eletrodos, de ferro e alumínio, foram conectadas a uma fonte de alimentação de energia.Todos os parâmetros físico-químicos foram determinados seguindo o Método Padrão para análise de água, enquanto que as concentrações de metal foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF), disponível no Laboratório Nacional de Luz Síncroton. A fim de determinar as condições ótimas de operação, os efeitos da intensidade da corrente, distância entre eletrodos, pH inicial do efluente e tempo de eletrólise foram avaliados experimentalmente, de acordo com um planejamento estatístico e análise de correlação. Para cada eletrodo, foram realizados 11 experimentos de EF com valores máximos e mínimos para os parâmetros de operação do reator. Empregando um nível de 95% de confiança na correlação de análises dos parâmetros a análise de correlação entre os parâmetros de EF, os modelos mostraram tendência de redução nas concentrações dos parâmetros físico-químicos e de metais, quando o pH inicial do efluente foi elevado, enquanto o tempo de EF e a voltagem aplicada apresentaram tendência de redução nos valores para uma menor distância entre os eletrodos.. Além disso, a eficiência do tratamento de EF tende a valores mais elevados com o aumento na intensidade de corrente. A fim de determinar as melhores condições de operação do reator, outros experimentos EF foram feitos variando o pH inicial de 6.5 a 9.0 e de 6.0 a 8.5 para eletrodos de ferro e alumínio, respectivamente, fixando a distância entre os eletrodos em 4.0 cm, a intensidade da corrente em 5.5 A e o tempo de EF em 30 minutos. Entretanto, esses experimentos mostraram que o fator de redução percentual na concentração dos parâmetros, causada pelo aumento no pH inicial do efluente, não foi significativo comparado aos experimentos anteriores. Nos tratamentos posteriores de EF, o pH do efluente foi mantido próximo ao original, evitando a introdução de outras substâncias no efluente. Mantendo o valor do pH do efluente em 7.5, outros experimentos de EF foram realizados variando o tempo de eletrólise de 15 a 120 min., e fixando a intensidade da corrente e distância entre os eletrodos em 5.5 A e 4.0 cm., respectivamente. Nessas condições, o tempo de EF fixado em 30 min. foi suficiente para alcançar uma boa eficiência, de acordo com o fator de redução, para maioria dos parâmetros analisados, sem aumentar muito a potência elétrica do reator, para os dois tipos de eletrodos. Os experimentos realizados com reator de EF mostraram uma alta eficiência na redução da turbidez e concentração de cromo (98%). Ademais, esse sistema também pode ser utilizado na redução de outras concentrações elementares como cálcio, potássio e zinco, para ambos os tipos de eletrodos (Fe/Al). Em comparação com os eletrodos de ferro, o eletrodo de alumínio apresentou um melhor fator de redução nos valores de DQO (80%) e um bom fator de redução de ferro (50%). Por outro lado, o método de EF para o tratamento de sistema de efluentes de curtumes foi também comparado ao método convencional utilizando agentes coagulantes e floculantes, mostrando uma grande semelhança entre eles no fator de redução. No método EF não é necessário introduzir substâncias para iniciar o processo de coagulação e floculação no tratamento de efluente.
|
294 |
Avaliação do potencial de utilização da macrófita aquática seca Salvinia sp. no tratamento de efluentes de fecularia / Evaluation of the potential use of dry aquatic macrophyte Salvinia sp. in an industrial cassava wastewater treatmentLimons, Rafaela da Silva 11 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:09Z (GMT). No. of bitstreams: 1
Rafaela da Silva Limons.pdf: 1188810 bytes, checksum: 3222e9bb51995ce2bffdbb6505a56d20 (MD5)
Previous issue date: 2008-02-11 / The industries of cassava processing are considered great polluting, therefore they generate highly pollutant a wastewater, the manipueira, with high concentration of organic substance. The method of treatment used in these industries is basically the system of stabilization. However, in function of the raised organic load, normally the effluent end if does not present in adequately favorable conditions for the ousting in hydrias resources, being essential a complementary treatment, so that the wastewater is adjusted to the current law. Thus, this work had for objective to study the removal of organic substance, nutrients and metals weighed, by means of a batelada system, for the dry biomass of the macrófita Salvinia sp. In this direction, with intention to investigate the factors that influence the capacity of removal of these contaminantes and to understand the mechanisms of this process, it was used as technique of factorial planning rotational central delineation composed - DCCR, verifying the influence of three independent 0 variable: pH initial, initial concentration of biomass - C and agitation -. The gotten results had shown that the best operational conditions had in accordance with varied the studied pollutant, thus best pH were: 5,8 for the match - P and zinc - Zn and 8,2 for the chemical demand of oxygen - DQO, nitrogen - N and have covered - Cu; the best concentration of biomass of 0,0013 g/mL for the DQO, the N, P and Zn and 0,0053 g/mL for the Cu and the 30 agitation of rpm for DQO and N and 120 rpm for the P, Zn and Cu. For the Compact disc removal of 100% in practically all was gotten the assays, in virtue of low the initial concentration of this metal. The gotten results had allowed to conclude respectively that in the best operational conditions the dry biomass of the Salvinia sp. influenced positively in process, reaching 97.91% of removal of DQO, 99.96% of P and 99.67% of N, with initial concentration of 20.480, 121,6 and 350 mg/L. Moreover, the results had shown to the promising character of the Salvinia sp. as biossorvente, being capable to adsorver up to 76,70% of íons of Zn, 99.79% of Cu and 100% of íons Compact disc, in industrias liquid residues contend small metal concentration heavy. The assays with the isotherms of adsorção of Zn and Cu had indicated that the capacity of biossorção of copper and 0,50 zinc had been approximately of 0,70 and meq/g in pH 5,0, being that the best adjustment occurred with the Isotherm of Sips. / As indústrias de processamento de mandioca são consideradas grandes poluidoras, pois geram um resíduo líquido altamente poluente, a manipueira, com alta concentração de matéria orgânica. O método de tratamento empregado nestas indústrias é basicamente o sistema de lagoas. Entretanto, em função da elevada carga orgânica, normalmente o efluente final não se apresenta em condições adequadamente favoráveis para o despejo em recursos hídricos, sendo essencial um tratamento complementar, para que o resíduo líquido esteja adequado à legislação vigente. Assim, este trabalho teve por objetivo estudar a remoção de matéria orgânica, nutrientes e metais pesados, por meio de um sistema batelada, pela biomassa seca da macrófita Salvinia sp. Neste sentido, com o intuito de investigar os fatores que influenciam a capacidade de remoção destes contaminantes e para se compreender os mecanismos deste processo, utilizou-se como técnica de planejamento fatorial o delineamento composto central rotacional - DCCR, verificando a influência de três variáveis independentes: pH inicial, concentração inicial de biomassa - C e agitação - A. Os resultados obtidos mostraram que as melhores condições operacionais variaram de acordo com o poluente estudado, assim o melhor pH foi: 5,8 para o fósforo - P e zinco - Zn e 8,2 para a demanda química de oxigênio - DQO, nitrogênio - N e cobre -Cu; a melhor concentração de biomassa de 0,0013 g/mL para a DQO, o N, P e Zn e 0,0053 g/mL para o Cu e a agitação de 30 rpm para a DQO e N e 120 rpm para o P, Zn e Cu. Para o Cd obteve-se remoção de 100% em praticamente todos os ensaios, em virtude da baixa concentração inicial deste metal. Os resultados obtidos permitiram concluir que nas melhores condições operacionais a biomassa seca da Salvinia sp. influenciou positivamente no processo, alcançando 97,91% de remoção de DQO, 99,96% de P e 99,67% de N, com concentração inicial de 20.480, 121,6 e 350 mg/L, respectivamente. Além disso, os resultados mostraram o caráter promissor da Salvinia sp. como biossorvente, sendo capaz de adsorver até 76,70% de íons de Zn, 99,79% de Cu e 100% de íons Cd, em resíduos líquidos industrias contendo pequena concentração de metais pesados. Os ensaios com as isotermas de adsorção de Zn e Cu indicaram que a capacidade de biossorção do cobre e zinco foram aproximadamente de 0,70 e 0,50 meq/g em pH 5,0, sendo que o melhor ajuste ocorreu com a Isoterma de Sips.
|
295 |
Aplicação dos processos foto-Fenton e eletrofloculação no tratamento de efluente de curtume / Application of the photo-Fenton and electrocoagulation processes at the tannery effluent treatmentBorba, Fernando Henrique 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:12Z (GMT). No. of bitstreams: 1
Fernando Henrique Borba.pdf: 3301834 bytes, checksum: 0c5216d667957cc99d5acd2dd5d59c05 (MD5)
Previous issue date: 2010-02-18 / Pollution is a currently environmental problem of world concern. There are many events such as the discharging of untreated effluents in watercourses that cause the eutrophization of water bodies and bad water quality, as well as an inefficiency or lack of a current environmental law. The main goal of this dissertation was the application of solar and artificial-based photo-Fenton processes and aluminum electrodes-based electrocoagulation method in non coupled mode and in an integrated mode for the tannery effluent treatment. These effluent treatments were carried out in lab-scale reactors. In order to evaluate the performance of the reactor experimental conditions of photo-Fenton reactor, a 33 complete experimental design was performed. The lab scale EC reactor was operated at the 4 A electrical current, 4 cm electrode distance and 3 initial pH optimized values, according to the previous results obtained in another work, while the electrolysis time was varied from 5 to 120 min. For EC and photo-Fenton reactors, their performance was evaluated on the removal values of chemical oxygem demand (COD), color, turbidity, total solids (TS), total fixed solids (TFS), total volatile solids (TVS) and metal concentration. Measurements of physico-chemical parameters for untreated and treated effluent samples were performed applying the Standard Method for water analysis, while metal concentrations were determined by the Synchrotron radiation total Reflexion X-ray Fluorescence technique at Brazilian Light Synchrotron Laboratory. By an optimized photon-Fenton process at 0.5 g Fe2+ L-1, 30 g H2O2 L-1, 3 initial pH, and 120 min reaction time, tannery effluent was treated achieving a high performance in pollutant removal as reported by 98.1, 96.4, 98.8, 71.8, 32.1 and 98.5 percent removal for COD, color, turbidity, TS, TFS, and TVS, respectively. As a primer treatment stage, electrocoagulation technique was not achieved a well successful result based on the physico-chemical parameter values reduction as compared with photo-Fenton process. However, an integrated solar irradiation-based photo-Fenton and Al electrodes-based electrocoagulation with 15 min electrolysis time has achieved recommended values by the Brazilian environmental law for Cr concentration (0.24 mg Cr L-1) and DQO (107 mg O2 L-1). Considering both the costs of electrical energy and material and the generated sludge discharging, one m3 of tannery effluent should cost R$ 56.30 for a treatment system based on an integrated and optimized photo Fenton and electrocoagulation processes. Finally, the integrated solar-based photo Fenton and electrocoagulation method is suggested as an efficient one, instead to apply a unique process. / A poluição ambiental é um dos grandes problemas nos países desenvolvidos e em desenvolvimento. Isto é decorrente de uma série de fatores, como o despejo de efluentes não tratados em corpos hídricos e a ineficiência e/ou a falta de legislação ambiental vigente. O objetivo principal deste trabalho é aplicar os processos foto-Fenton com irradiação solar e/ou artificial, a técnica da eletrofloculação e a integração destes processos no tratamento de efluente de curtume. Ambos os processos de tratamento do foto-Fenton e da eletrofloculação foram conduzidos em reatores a escala laboratorial. Para a técnica da eletrofloculação foi utilizado um par de placas de alumínio como eletrodos no reator de eletrofloculação. Para avaliar as melhores condições de processo do sistema foto-Fenton, foi aplicado um planejamento experimental 33 completo. Para a técnica da eletrofloculação manteve-se constante a intensidade de corrente, pH inicial do efluente bruto e distância entre os eletrodos, variando-se o tempo de eletrólise de 5 à 120 min. A eficiência de ambos os processos foram avaliadas com base na redução de Demanda química de oxigênio (DQO), cor, turbidez, sólidos totais (ST), sólidos totais fixos (STF), sólidos totais voláteis (STV). Para a técnica da eletrofloculação e dos processos integrados também foram avaliados a redução da concentração dos metais pesados. Todas as medidas dos parâmetros físico-químicos foram realizadas aplicando os métodos padrões do Standard Methods for the Examination of Water and Wastewater para amostra não tratada e tratada. As concentrações dos metais pesados foram determinadas usando a técnica de fluorescência de raio X por reflexão total, na linha de Luz (D09-XRF) do Laboratório Nacional de Luz Synchrotron. A maior eficiência na redução dos poluentes verificada no processo foto-Fenton foi de 98,1, 96,4, 98,8, 71,8, 32,1 e 98,5 para valores da DQO, cor, turbidez, ST, STF e STV, respectivamente, nas condições operacionais do reator: concentração de ferro de 0,5 gL-1, concentração de peróxido de hidrogênio de 30 gL-1, pH inicial 3 e tempo reacional de 120 min. No entanto a técnica da eletrofloculação não apresentou boa redução nos valores dos parâmetros físico-químicos. Após a aplicação dos processos integrados do foto-Fenton com irradiação solar e da eletrofloculação em tempo de eletrólise de 15 min, foi alcançado valores mínimos de Cr e DQO no efluente tratado, contendo 0,24 mg Cr L-1 e 107 mg O2 L-1 da DQO. O custo do tratamento do efluente e da disposição final do lodo gerado no processo integrado FFs→EF foi de R$ 56,30 m3 do efluente de curtume tratado. Este processo integrado reduziu as concentrações de cromo, ferro e DQO, a níveis permitidos pelas legislações ambientais. Baseada na redução da matéria orgânica e inorgânica, o método integrado FFs→EF pode ser recomendado como uma substituição eficiente ao método individual.
|
296 |
Utilização da eletrocoagulação no tratamento de efluente da indústria galvânica / Use of electrocoagulation in the treatment of wastewater from galvanizing industryTheodoro, Paulo Sérgio 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:14Z (GMT). No. of bitstreams: 1
Paulo Sergio Theodoro.pdf: 1744465 bytes, checksum: 132da5a46d9247da552f8a27ee087fed (MD5)
Previous issue date: 2010-02-18 / The aim of this work is devoted to reduction of the environmental impact of galvanic industry effluents. An electro-coagulation (EC) laboratory scale system using iron plates electrodes was studied for the removal of organic and inorganic pollutants as a by-product from the treatment of galvanic process based-platining industry. An EC reactor consisting of a 1,5 L conical container and a set of seven firmly assembled iron electrode plates, which were parallelly arranged to each other and electrically operated in mono-polar mode, was built. A 1.0 cm gap between the anode and cathode plates using a non-conducting horizontal support was chosen in order to operate the EC reactor in a low electrical current range. A long, electrical rotating cilindrical rotor, with 2,7cm blades at the end of it, made in non-conducting material, was used to turn mechanically the effluent around the rotor axis during the EC treatment. In addition, a 225 cm2 active electrode surface area was kept during the whole EC experiments. In order to obtain optimal values of reaction time, electrical current, rotor angular velocity, and initial effluent pH, a central composite rotatable design (CCRD) was applied. A wide range of reaction time (10-60 min), electrical current (0.3-3.0 A), rotor angular velocity (50-300 rpm), and initial efluent pH (3-10) were used, performing a total of 28 runs with 24+2x4 axial points and 4 central points. Physico-chemical parameters such as chemical oxygen demand (COD), color, turbidity, total solids, and metals (Cr, Ni, Zn, and Cu) were used as response variables. The measurements of physico-chemical parameter and metal concentration values in non- and treated waste waters were carried out by applying the Standard Methodology and the Synchrotron Radiation X-Ray Fluorescence (SR-TXRF) technique, respectively. Using the Statistica software, a 95%-significance level (p<0.05) of the predicted models and interaction effects between reactor operating variables on response variables were evaluated using 3-D response surface curves and analysis of variance. With the factorial design was obtained the following optimum conditions of the reactor, 35 minutes for the time of electrolysis, 170 rpm for agitation, 2.2 A for the electric current and 6.5 for pH. Under these conditions the removal of color and turbidity reached 100%, another considerable value was the removal of around 90% of COD and total solids. Moreover, a removal of around 99% of Zn and Cu was obtained, whereas for Cr and Ni obtained a removal of 100%. Finally, the results of technical and economic analysis showed the cost obtained by the treatment, indicating clearly that the method of electro-coagulation is very promising for industrial application. / O presente trabalho tem como objetivo remover os poluentes de um efluente de galvanização, de modo a reduzir o impacto ambiental dos efluentes da indústria galvânica. Para a remoção dos poluentes, orgânicos e inorgânicos, gerado nos processos de galvanização foi aplicada a eletrocoagulação (EC) em escala de laboratório utilizando eletrodos de ferro. Foi construído um reator de EC, constituído por um recipiente cônico com capacidade de 1,5 L e um eletrodo de ferro montado firmemente com seis placas de ferro, que foram dispostas paralelamente com uma distância de 1(um) centímetro, operado em modo mono-polar. O sistema de agitação mecânico foi construído com duas pás de geometria cilíndrica de 2,7 cm e uma haste de 31,5 cm feito com material não condutor acoplado em um motor elétrico. Durante o experimento da EC foi utilizada uma área efetiva de 225 cm2 do eletrodo. A fim de obter valores ideais do tempo de eletrolise, corrente elétrica, agitação e pH inicial do efluente, foi aplicado o planejamento estatístico composto central (DCCR) com fatorial 24+2X4 pontos axiais + 4 ponto centrais, totalizando 28 ensaios experimentais. Os valores aplicados as variáveis independentes foram de 0,3 a 3 A para a corrente, de 10 a 60 min. para o tempo de eletrolise, de 3 a 10 para o pH inicial e agitação como valores entre 50 e 300 rpm. Foram utilizadas como variáveis resposta os parâmetros físico químico tais como, a demanda química de oxigênio (DQO), cor, turbidez, Sólidos totais e concentração dos metais Cr, Ni, Zn e Cu.Todos os parâmetros físico-químicos foram determinados através o Método Padrão para análise de água, enquanto que as concentrações dos metais foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF). Utilizando o software Statistica, com nível de significância de 95% (p <0,05), os modelos preditos e os efeitos de interação entre as variáveis de operação do reator e as variáveis respostas foram avaliados, utilizando as curvas 3-D de superfície de resposta e a análise de variância. Com o planejamento fatorial foi obtido as seguintes condições ótimas de trabalho do reator, 35 minutos para o tempo de eletrolise, 170 rpm para a agitação, 2,2 A para a corrente elétrica e 6,5 para o pH. Nestas condições a remoção da cor e turbidez alcançaram 100%, outro valor considerável foi a remoção em torno de 90% da DQO e sólidos totais. Além disso, uma remoção em torno de 99% de Zn e Cu também foi obtida, enquanto que para o Cr e Ni obteve-se uma remoção de 100%. Finalmente, os resultados da análise técnico-econômica mostraram o baixo custo obtido pelo tratamento, evidenciando claramente que o método da eletrocoagulação é muito promissor para aplicação industrial.
|
297 |
Avaliação da remoção do corante comercial reativo Azul 5G utilizando macrófita Salvínia sp. / Evaluation of the removal of commercial reactive blue 5G dye using macrophyte Salvínia sp.Cervelin, Patricia Caroline 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:15Z (GMT). No. of bitstreams: 1
Patricia C Cervelin.pdf: 689466 bytes, checksum: b74333db0911dc152167518d0ffcac74 (MD5)
Previous issue date: 2010-02-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Among the main contributors to the contamination of water by industrial waste is the textile industry. The textile sector is a major producer of chemicals, such as colors, and generator large volumes of effluent. The textile dye is a product of high toxicity, and most of them are considered carcinogenic. Thus the removal of dyes in industrial effluents is of great interest, since such contaminants can affect water clarity, the solubility of gases in receiving bodies and change the processes of photosynthesis. In addition there are technologies for the removal of dye of effluent, such as activated charcoal, few studies have examined the ability of dye removal by biological origin, which would decrease the cost of treating this waste. Thus the process of biosorption used in this study was to investigate the application of macrophyte Salvinia sp. in nature and pre-treated in a basic with NaOH, and an acid with H3PO4, as low cost biosorbent for the removal of dye Blue 5G. The effect of pH and temperature was investigated in the biosorption process and proved to be variables that affect the ability to remove the dye solution. The adsorption data were adjusted to balance using the kinetic models of pseudo-first order and pseudo-second order. The models of adsorption isotherms of Langmuir, Freundlich and Sips were used to describe the experimental data of equilibrium of biosorption process. The thermodynamic parameters of biosorption process were obtained. The results showed that the balance of the system was reached in approximately 48 hours of contact, with removal of dye Blue 5G of 98.35% for the Salvinia sp. in nature, at pH 1 and temperature of 60°C and 97.06% for the Salvinia sp. pre-treated with NaOH, 96.42% for the Salvinia sp. pre-treated with H3PO4 at a temperature of 45°C. The model of pseudo-second order showed satisfactory fit with experimental data. Among the models studied, the Langmuir isotherm described excellently the experimental data for the three biomasses studied, with maximum adsorption capacity of 24.26 mg/g at 30°C for biomass pre-treated in basic mean. The study of thermodynamic parameters of biosorption of dye Blue 5G showed that biosorption is endothermic nature and has a great affinity between the biomass and dye. This study found that the biomass of macrophyte Salvinia sp. pré-treated with NaOH has potential application in the removal of reactive dye Blue 5G, as alternative adsorbent and low cost. / Entre os principais contribuintes para a contaminação de águas por resíduos industriais pode-se citar a indústria têxtil. O setor têxtil é conhecido pela elevada utilização de produtos químicos, como os corantes, e gerador de grandes volumes de efluente. O corante têxtil é um produto de alta toxicidade, sendo que em sua maioria são considerados carcinogênicos. Desta forma a remoção de corantes em efluentes industriais é de grande interesse, uma vez que esse contaminante pode afetar a transparência da água, a solubilidade dos gases nos corpos receptores e alterar os processos de fotossíntese. Mesmo com variadas tecnologias para remoção de corante do efluente, como carvão ativado, são raros os estudos que tem analisado a capacidade de remoção de corantes por origem biológica, o que diminuiria os custos de tratamento desse resíduo. Desta forma o processo de biossorção empregado neste trabalho teve por objetivo investigar a aplicação da macrófita Salvínia sp. in natura, e pré-tratada em meio básico com NaOH, e em meio ácido com H3PO4, como biossorvente de baixo custo para a remoção do corante comercial reativo Azul 5G. O efeito do pH e da temperatura foi investigado no processo de biossorção e mostraram ser variáveis que afetam a capacidade de remoção do corante da solução. Os dados de adsorção de equilíbrio foram ajustados empregando os modelos cinéticos de pseudo-primeira ordem e pseudo-segunda ordem. Os modelos de isotermas de adsorção de Langmuir, Freundlich e Sips foram utilizados para descrever os dados experimentais de equilíbrio do processo de biossorção. Os parâmetros termodinâmicos do processo de biossorção foram obtidos. Os resultados demonstraram que o equilíbrio do sistema foi atingido em aproximadamente 48 horas de contato, com remoção de corante Azul 5G de 98,35% para a Salvínia sp. in natura e 97,06% para a Salvinia sp. pré-tratada com NaOH, em pH 1 e temperatura de 60°C, e remoção de 96,42% para a Salvínia sp. pré-tratada com H3PO4 em temperatura de 45°C. O modelo de pseudo-segunda ordem apresentou ajuste satisfatório com os dados experimentais. Entre os modelos estudados, a isoterma de Langmuir e Sips descreveram satisfatoriamente os dados experimentais para as três biomassas estudadas, apresentando capacidade máxima de adsorção de 24,26 mg/g e 24,83 mg/g, para Langmuir e Sips, respectivamente, à temperatura de 30°C para a biomassa pré-tratada em meio básico. O estudo dos parâmetros termodinâmicos de biossorção do corante Azul 5G demonstrou que a biossorção é de natureza endotérmica e demonstra grande afinidade entre a biomassa e o corante. Este estudo verificou que a biomassa da macrófita Salvínia sp. pré-tratada com NaOH apresenta potencial de aplicação na remoção do corante reativo Azul 5G, como adsorvente alternativo e de baixo custo.
|
298 |
Tratamento de águas residuárias da indústria de laticínios pelos processos combinados coagulação/floculação/adsorção/ultrafiltração utilizando semente de Moringa oleífera como coagulante / Wastewater treatment of dairy industry by combined process coagulation/flocculation/adsorption/ultrafiltration using Moringa oleífera seed as coagulantSchmitt, Dalila Maria Formentini 16 February 2011 (has links)
Made available in DSpace on 2017-07-10T18:08:18Z (GMT). No. of bitstreams: 1
Dalila M Formentini Schmitt.pdf: 1687104 bytes, checksum: d5ea17cddd5fa8a48f15d9203dd84077 (MD5)
Previous issue date: 2011-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In Brazil, the dairy industry are mostly small and medium-sized and using conventional processing techniques coupled with the use of inorganic coagulants. Therefore, this sector needs special attention with regard to advanced techniques for treating their wastewater, in order to meet new environmental regulations and seek alternatives for reuse of treated water. Within this context, this study evaluated the effectiveness of treatment techniques based on principles of coagulation / flocculation using coagulant extracted from Moringa oleifera seed with salt solutions of KCl and NaCl 1.0 Molar, adsorption with Moringa oleífera seed as biosorbent and ultrafiltration with tubular ceramic membrane. The different techniques were evaluated individually and in combination, the efficiency of processes was assessed in terms of removal of parameters: apparent color, turbidity and COD. Among the techniques evaluated the best results were obtained with the combination of technique and the coagulation / flocculation / sedimentation for 60 min using 1500 ppm of coagulant extracted from Moringa oleífera with 1.0 Molar KCl solution combined with ultrafiltration technique at a pressure of 2 bar. This combination of techniques has achieved a 99.9% removal of apparent color and turbidity, and 98.5% of COD. Based on the results of Moringa oleífera was presented as a promising natural coagulant for the treatment of wastewater from the dairy industry. This technique combined with ultrafiltration can enable the reuse of water within the industry. / No Brasil, as indústrias de laticínios na sua maioria são de pequeno e médio porte e utilizam técnicas de tratamento convencionais somadas ao uso de coagulantes inorgânicos. Por isso, este setor precisa de atenção especial no que se refere a técnicas avançadas para o tratamento de suas águas residuárias, com objetivo de atender as novas regulamentações ambientais e buscar alternativas de reúso desta água tratada. Dentro deste contexto, o presente trabalho avaliou a eficiência das técnicas de tratamento baseadas nos princípios de coagulação/ floculação utilizando coagulante extraído da semente de Moringa oleífera com soluções salinas de KCl e NaCl 1,0 Molar, adsorção com semente de Moringa oleífera como biossorvente e ultrafiltração com membrana tubular cerâmica. As diferentes técnicas foram avaliadas individualmente e de forma combinada, a eficiência dos processos foi avaliada em termos de remoção dos parâmetros: cor aparente, turbidez e DQO. Dentre as técnicas avaliadas os melhores resultados foram obtidos com a combinação da técnica de coagulação/ floculação/ sedimentação de 60 min utilizando 1500 ppm do coagulante de Moringa oleífera extraído com solução de KCl 1,0 Molar combinada à técnica de ultrafiltração na pressão de 2 bar. Esta combinação de técnicas alcançou uma remoção de 99,9% de cor aparente e turbidez e 98,5% de DQO. Com base nos resultados obtidos a Moringa oleífera apresentou-se como um coagulante natural promissor para o tratamento das águas residuárias da indústria de laticínios. Esta técnica combinada à ultrafiltração pode possibilitar o reúso desta água dentro da indústria.
|
Page generated in 0.0559 seconds