Spelling suggestions: "subject:"1ndice BODE"" "subject:"andice BODE""
1 |
Testes funcionais e a relação com o índice BODE na doença pulmonar obstrutiva crônicaRegueiro, Eloisa Maria Gatti 24 April 2008 (has links)
Made available in DSpace on 2016-06-02T20:19:07Z (GMT). No. of bitstreams: 1
1752.pdf: 1459122 bytes, checksum: 300e94014e88196b37e1ec53acd4912a (MD5)
Previous issue date: 2008-04-24 / Universidade Federal de Sao Carlos / Objectives: To investigate three variables of the respiratory process pulmonary ventilation ( E),
oxygen consumption ( O2), and production of carbon dioxide ( CO2) during Activities of Daily
Living (ADL) and functional tests of the lower limbs (LL) in individuals with Chronic Obstructive
Pulmonary Disease (COPD) and Control Group; verify if the methods employed to evaluate ADL
adequately reflect the functional limitation of individuals with COPD; and if there is a correlation between the variables evaluated during ADL, the performance on Lower Limb tests and peripheral muscle impairment of the Upper Limbs (UL) to the BODE Index (Body mass index; airflow Obstruction; Dyspnea and Exercise capacity) in individuals with COPD. Material and Methods: The sample was composed of 17 men from the ages of 58 to 80 years old, ten of whom had moderate to severe pulmonary obstruction composed the COPD Group (COPDG) and seven healthy men composed the Control Group (CG). All performed the ADL Test and were evaluated by ventilatory and metabolic variables; the Six Minute Walking Test in Corridor (6MWTC) by
Distance Walked (DW); the Six Minute Walking Test on Treadmill (6MWTT) by DW and velocity;
the Sit To Stand Test (STST) by the number of sit and stand up repetitions performed and the Hand
Grip Strength Test in different postures. The COPDG was classified by the BODE Index and
correlations between the tests performed and the BODE Index were found for the COPDG. Results:
Intergroup analysis detected significant differences (p<0.05) in relation to ADL of lifting container to eye level ( E, CO2), combing hair, lifting containers to above shoulder level, hanging out clothes on the clothesline and sweeping the floor ( CO2) and in 6MWTC for DW, 6MWTT for
velocity and STST for number of repetitions of sitting and standing from chair. The BODE Index
presented a strong (r≥0.66) to 6MWTT, STST and Hand Grip Strength. Conclusion: Individuals with COPD present a lower tolerance for physical effort compared to the CG during performance of the ADL and LL tests. The methods employed to evaluate the ADL did not reflect the functional limitation of the COPDG which was primarily composed of individuals with moderate obstructions. The Bode Index predictor of severity presented an association to limiting factors evaluated in the 6MWTT, STST and Hand Grip Strength Test for the COPDG; and thus suggests the possible use of these same tests to calculate physical exercise capacity in the BODE Index. / Objetivos: investigar o comportamento da ventilação pulmonar ( E) do consumo de oxigênio ( O2) e da produção de dióxido de carbono ( CO2) nas atividades da vida diária (AVD) e nos testes funcionais de membros inferiores (MMII) dos indivíduos com doença pulmonar obstrutiva crônica (DPOC) e controle; verificar se os métodos empregados para a avaliação das AVD refletem adequadamente a limitação funcional dos indivíduos com DPOC; e se há correlação entre as variáveis avaliadas durante as AVD, o desempenho nos testes de MMII e o comprometimento muscular periférico de membros superiores (MMSS) com o índice BODE (Body mass index; airflow Obstruction; Dyspnea and Exercise capacity) nos indivíduos com DPOC. Material e Métodos: A amostra foi composta por 17 homens na faixa etária de 58 a 80 anos, sendo dez com DPOC de obstrução pulmonar moderada a muito grave compondo o grupo DPOC (GDPOC) e sete saudáveis compondo o grupo controle (GC). Todos foram avaliados quanto a realização do teste das
AVD pelas variáveis ventilatórias e metabólicas; ao teste de caminhada de seis minutos em corredor (TC6Co) pela distância percorrida (DP); ao teste de caminhada de seis minutos em esteira (TC6E) pela DP e velocidade; ao teste de sentar e levantar da cadeira (TSLC) pelo número de repetições ao sentar e levantar e ao teste de preensão palmar em diferentes posturas. O GDPOC foi classificado quanto ao índice BODE e foram realizadas correlações entre os testes realizados e esse índice nesse mesmo grupo. Resultados: a análise intergrupo detectou diferença significativa (p<0,05) em relação a AVD de elevar potes na altura dos olhos ( E, CO2), pentear os cabelos, elevar potes acima dos ombros, estender roupa no varal e varrer o chão ( CO2) e nos TC6Co quanto a DP, no TC6E quanto a velocidade e no TSLC quanto ao número de repetições ao sentar e levantar da
cadeira. Constatou-se ainda que o índice BODE apresentou forte correlação (r≥0,66) com o TC6E, TSLC e com a força de preensão palmar. Conclusão: os indivíduos com DPOC apresentaram menor tolerância ao esforço físico comparado ao GC durante a realização das AVD e dos testes de MMII. Que os métodos empregados para a avaliação das AVD utilizados não refletiram a limitação funcional do GDPOC que apresentou predominantemente moderada obstrução; e que o preditor de gravidade índice BODE apresentou associação com os fatores limitantes avaliados nos TC6E, TSLC e com a força de preensão palmar nesse grupo; apontando a possibilidade de sugerir a
utilização dos mesmos na determinação da capacidade de exercício físico no cálculo do índice BODE.
|
2 |
Relação da força muscular de membros superiores e inferiores e índices de gravidade na doença pulmonar obstrutiva crônicaMarino, Diego Marmorato 16 February 2009 (has links)
Made available in DSpace on 2016-06-02T20:19:10Z (GMT). No. of bitstreams: 1
2257.pdf: 1719457 bytes, checksum: a8bbb05ab969a42bf231021b441fe5f0 (MD5)
Previous issue date: 2009-02-16 / Financiadora de Estudos e Projetos / Introduction: Individuals with chronic obstructive pulmonary disease (COPD) present a decrease in peripheral muscle strength, leading to impaired mobility and increased death risk. However, there are a lack of studies that verify if the peripheral muscle strength have relationship with the BODE index scale and fat-free mass. Objectives: To verify the relationship between maximum upper-limb (UL) muscle strength and lower-limb (LL) muscle strength with a BODE index, isolated variables and fat-free mass in subjects with moderate to very severe COPD. Methods: Twenty-six individuals with moderate to very severe COPD (FEV1<80% of predict) were evaluated regarding body composition (body mass index-BMI and fat-free mass), BODE index, handgrip force (HGF) and one repetition maximum test (1RM) of the UL and LL. Results: Observed moderate to strong positive correlation (Pearson, p <0.05) between peripheral muscle strength with the fat-free mass and distance walked in the six-minute walk test (6MWD). However, the BODE index were not correlated with force measurement or fat-free mass. Conclusion: It can be concluded that the evaluation of peripheral muscle strength is not related to the BODE index. In such case, the peripheral muscle force measures need be used assisting the assessment of COPD subjects performance. / Introdução: Indivíduos com doença pulmonar obstrutiva crônica (DPOC) apresentam redução da força muscular periférica, conduzindo à mobilidade prejudicada e aumento do risco de morte. No entanto, há uma escassez de estudos que verificam se a força muscular periférica tem relação com o índice BODE e a massa magra. Objetivos: Verificar se há relação entre a força muscular de membros superiores (MMSS) e membros inferiores (MMII) com índice BODE, suas variáveis isoladas e massa magra em indivíduos com DPOC apresentando obstrução moderada a muito grave. Métodos: Vinte e seis indivíduos com DPOC moderada a muito grave (VEF1<80% do previsto) foram avaliados quanto à composição corporal (índice de massa corpórea IMC e massa magra), índice BODE, força de preensão palmar (FPP) e teste de uma repetição máxima (1RM) dos MMSS e MMII. Resultados: Observou-se correlação positiva moderada a forte (Pearson, p<0,05) entre a força muscular periférica com a massa magra e distância percorrida no teste de caminhada de seis minutos (TC6). No entanto, o índice BODE não se correlacionou com parâmetros de força ou massa magra. Conclusão: Conclui-se que a avaliação da força muscular periférica não se relaciona com o índice BODE. Neste sentido, as medidas de força muscular periférica devem ser utilizadas auxiliando a avaliação da performance dos indivíduos com DPOC.
|
3 |
Cinética do consumo de oxigênio e da frequência cardíaca, índice BODE e a influência de dois programas de treinamento físico em pacientes com doença pulmonar obstrutiva crônicaPessoa, Bruna Varanda 29 February 2012 (has links)
Made available in DSpace on 2016-06-02T20:18:17Z (GMT). No. of bitstreams: 1
Retido.pdf: 19733 bytes, checksum: 6aad255badc436a06364517de2344ab6 (MD5)
Previous issue date: 2012-02-29 / Financiadora de Estudos e Projetos / The thesis consisted of three studies described below. The study I, entitled: Oxygen uptake and heart rate on-kinetics in patients with Chronic obstructive pulmonary disease (COPD): comparison between cycle ergometry and elliptical equipment aimed to evaluate and compare the kinetics of both oxygen consumption (VO2) and heart rate (HR) in constant work-rate tests on a cycle ergometer (CCT) and on an elliptical machine (ECT) in COPD patients and healthy individuals. Eighteen male COPD patients between 55 and 78 years old with moderate to very severe obstruction (COPD group) and 18 apparently healthy males (control group: CG) were evaluated; the subjects were paired by age and submitted to the following tests on alternate days: 1) symptom-limited incremental cycle ergometer test (IT); 2) CCT and 3) ECT, both at 70% of the maximum intensity obtained in the IT. Expired gases were collected in all tests, and the kinetics of VO2 and HR were analyzed. The COPD group presented significantly higher tau (τ) and mean response time (MRT) for VO2 on the CCT than the CG (p<0.05); however, there was no significant difference on the ECT. Regarding the different tests, the COPD group had a significantly higher τ and MRT on the CCT than the ECT; on the other hand, no differences between the tests were observed in the CG. We conclude that VO2 kinetics are slowed in COPD; however, this depends on the ergometer used for testing. The faster kinetics found on the ECT for the COPD group may be related to the effects of the body position or to higher recruitment of muscle fibers, as well as to the greater ventilatory and chronotropic stress observed in this test. Following, the study II, entitled: BODE index, body composition, peripheral muscle strength and oxygen uptake and heart rate kinetics on a cycle ergometer and on elliptical equipment in COPD patients: there is relationship between them? aimed to determine if there is a relationship between oxygen consumption (VO2) and heart rate (HR) on-kinetics in constant work-rate exercise test on cycle ergometer (CCT) and on elliptical equipment (ECT) with the BODE index and their isolated variables, muscle mass (MM), lean body mass index (LBMI) and with peripheral muscle strength (PMS) represented by one-repetition maximum strength test (1RM) in patients with COPD. Fourteen men patients with moderate to very severe COPD (COPD group), between 55 and 78 years, were submitted to the following tests on alternate days: 1) six-minute walking test (6MWT); 2) IT; 3) CCT and 4) ECT at 70% of the maximum intensity obtained in CPT; 5) 1RM test and 6) body composition evaluation. Expired gases were collected in CPT, CCT and ECT, and response of the VO2 and HR on-kinetics were analyzed. The BODE index was calculated. The BODE index was calculated. The Pearson correlation coefficient (p<0.05) presented a moderate positive relationship between BODE index and τ and MRT of VO2 and HR (r=0.55 and r=0.63; r=0.66 and r = 0.74, respectively); and negative correlation between τVO2 and MRT-VO2 with FEV1 (r=-0.69; r=-0.68), DW- 6MWT (r=-0,.62; r=-0.65) and DW-6MWT %predict (r=-0.64; r=-0.70). Still, significant negative correlations were observed between the τ-HR and MRT-HR with DW-6MWT (r=- 0,.81; r=-0.82) and DW-6MWT %predict (r=-0.83; r=-0.65). Significant correlations between the TRM and τ of VO2 and of HR with MM, LBMI and PMS; and correlations with oxygen consumption (VO2) and heart rate (HR) on-kinetics in ECT were not observed. In general, our data show that patients with moderate to very severe COPD have slowed VO2 kinetics in the CCT compared the ECT. Furthermore, the VO2 and HR on-kinetics in CCT has a moderate correlation with the classification of COPD severity assessed by the BODE index, FEV1 and DW-6MWT, showing that COPD severity, airflow limitation and exercise capacity are reflected by the slowing of the on-kinetics in COPD patients, but it depends on the ergometer. Finally, the study III, entitled: Effect of aerobic/resisted and interval physical training on oxygen uptake and heart rate on-kinetics in patients with COPD: randomized, controlled trial evaluated and compared the effect of aerobic/resisted physical training (TFAR) and interval physical training program on elliptical equipment (TFI) of high intensity on VO2 and HR onkinetics during CCT and ECT in patients with COPD. Eighteen men patients with moderate to very severe COPD, between 55 and 80 years, randomly divided into two groups: nine of the patients had been engaged in TFAR group, and nine in TFI group, were submitted to the following tests on alternate days: 1) IT; 2) CCT, and 3) ECT both at 70% of the maximum intensity obtained in IT, and one repetition maximum test (1RM), being reevaluated after six weeks physical training. program. The TFAR group consisted of aerobic training by thirty minutes, and three sets of fifteen repetitions of resisted training in lower limbs on leg press. The TFI group realized training program on an elliptical equipment, by thirty minutes at 100% of the maximum intensity obtained in IT, separated by 1-min rest periods. The two training groups completed 6 week (3x/week) of exercise training, until completing a total of eighteen sessions. Expired gases were collected in in all tests, and response of the VO2 and HR on-kinetics were analyzed. No significant difference post-training in the TFAR group both tests (CCT and ECT) were observed; but, the TFI group displayed slower VO2 onkinetics (> τ and > MRT) in the CCT and ECT after training. In relation HR on-kinetics, no significant difference in both groups and both constant workload exercise tests post-training were observed. We conclude that the interval physical training program on elliptical equipament lead to slower VO2 kinetics the onset at high-intensity exercise (CCT and ECT) in patients with COPD. Furthermore, the TFAR program is no sufficient to provoke improvements in VO2 and HR on-kinetics in the CCT and ECT. / A tese constou de três estudos descritos a seguir. O estudo I, intitulado: Cinética-on do consumo de oxigênio (VO2) e da frequência cardíaca (FC) de pacientes com doença pulmonar obstrutiva crônica (DPOC): comparação entre cicloergômetro e equipamento elíptico teve como objetivo avaliar e comparar a cinética do VO2 e da FC em testes de carga constante em cicloergômetro (TCC) e em equipamento elíptico (TCE), em pacientes com DPOC e indivíduos saudáveis. Foram avaliados 18 homens com DPOC de obstrução moderada a muito grave (grupo DPOC) entre 55 e 78 anos e 18 homens aparentemente saudáveis (grupo controle: GC) pareados por idade, submetidos em dias alternados aos seguintes testes: 1) teste incremental em cicloergômetro (TI) limitado por sintomas; 2) TCC e 3) TCE ambos a 70% da intensidade máxima obtida no TI. Foram coletados os gases expirados em todos os testes, e a cinética do VO2 e da FC foram analisadas. O grupo DPOC apresentou a tau (τ) e o tempo de resposta média (TRM) do VO2 significativamente maiores no TCC em comparação ao GC (p<0,05), porém sem diferenças significativas para o TCE. Em relação aos diferentes testes, no grupo DPOC a τ e o TRM foram significativamente maiores no TCC em comparação ao TCE (p<0,05), em contraste, no GC, não foram observadas diferenças significativas entre os testes. Concluímos que a cinética do VO2 é lentificada na DPOC, entretanto, a mesma depende do ergômetro testado. A cinética mais rápida encontrada no TCE no grupo DPOC pode estar relacionada aos efeitos da posição corporal adotada ou ao maior recrutamento de fibras musculares, bem como ao maior estresse ventilatório e cronotrópico observado neste teste. Na sequência, o estudo II, intitulado: Índice BODE, composição corporal, força muscular periférica e cinética-on do consumo de oxigênio e da frequência cardíaca em cicloergômetro e em equipamento elíptico em pacientes com DPOC: há correlação entre eles? objetivou verificar se há correlação entre a cinética-on do VO2 e da FC no TCC e no TCE com o índice BODE e suas variáveis isoladas, massa muscular (MM), índice de massa magra corporal (IMMC) e com a força muscular periférica (FMP) representada pelo teste de uma repetição máxima (1RM) em pacientes com DPOC. Foram avaliados 14 homens com DPOC de obstrução moderada a muito grave entre 55 e 78 anos, submetidos em dias alternados aos seguintes testes: 1) teste de caminhada de seis minutos (TC6); 2) TI; 3) TCC e 4) TCE ambos a 70% da intensidade máxima obtida no TI; 5) teste de uma repetição máxima (1RM) e 6) avaliação da composição corporal. Foram coletados os gases expirados no TI e TCC, e a cinética do VO2 e da FC foram analisadas. O índice BODE foi calculado. Observou-se correlação moderada entre a τ e o TRM do VO2 e da FC com o índice BODE no TCC (r=0,55 e r=0,63; r=0,66 e r = 0,74, respectivamente); e correlações negativas significativas entre a τ e o TRM do VO2 com o VEF1 (r=-0,69; r=-0,68), a distância percorrida no TC6 (DP-TC6) (r=-0,62; r=-0,65) e a DP-TC6 %prevista (r=-0,64; r=-0,70). Ainda a τ e o TRM da FC correlacionou-se com a DP-TC6 (r=-0,81; r=-0,82) e a DP-TC6 %prevista (r=-0,83; r=-0,65). Esse mesmo comportamento não foi observado para a cinética do VO2 e da FC no TCE. Não foram observadas correlações estatisticamente significativas entre a τ e o TRM do VO2 e da FC com a MM, IMMC e FMP. Concluímos que a cinética-on do VO2 e da FC no TCC correlacionou-se com o índice BODE, VEF1 e DPTC6, mostrando que a gravidade da doença, limitação ao fluxo aéreo e a capacidade ao exercício são refletidas pela lentificação da cinética, entretanto a mesma depende do ergômetro utilizado. Finalmente, o estudo III, intitulado: Efeitos do treinamento físico aeróbio/resistido e intervalado na cinética-on do VO2 e da FC em pacientes com DPOC: estudo controlado, randomizado avaliou e comparou os efeitos do treinamento físico aeróbio/resitido (TFAR) e treinamento físico intervalado de alta intensidade em equipamento elíptico (TFI) na cinética-on do VO2 e da FC no TCC e no TCE em pacientes com DPOC. Dezoito homens com DPOC, foram randomizados para: grupo de TFAR (n=9) e grupo TFI (n=9), e submetidos ao: 1) TI; 2)TCC e 3)TCE ambos a 70% da intensidade máxima obtida no TI; e 4)teste de uma repetição máxima (1RM); reavaliados após seis semanas de treinamento físico. O grupo TFAR realizou 30 minutos de cicloergômetro, com intensidade entre 60-70% da carga máxima atingida no TI, sendo aumentados 10% após três semanas de treinamento; e três séries de 15 repetições em leg-press com intensidade de 40-60% da carga máxima tolerada no teste de 1RM, sendo aumentado 10% a cada duas semanas de treinamento, e adotou-se intervalo de dois minutos entre as séries. Já, o grupo TFI realizou 30 minutos de treinamento em equipamento elíptico com carga máxima atingida no TI e intervalos de um minuto. Ambos os programas foram realizados 3x/semana por seis semanas, completando 18 sessões. Foram coletados os gases expirados no TI, TCC e TCE, e a cinética do VO2 e da FC foram analisadas. Não foram observadas diferenças significativas na cinética do VO2 após o treinamento físico no grupo TFAR, em ambos os testes. Entretanto, no grupo TFI, verificou-se lentificação da mesma no TCC e no TCE após o treinamento. Quanto à cinética-on da FC, não foram constatadas diferenças significativas nos dois grupos e testes, após os dois programas. Concluímos que a cinética-on do VO2 é lentificada nos pacientes com DPOC, quando realizam TCC e TCE após o programa de TFI de alta intensidade. Entretanto, o programa de TFAR não proporcionou benefícios na cinética-on do VO2 e da FC na DPOC, nos TCC e TCE.
|
Page generated in 0.0349 seconds