• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 209
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 213
  • 156
  • 48
  • 45
  • 44
  • 41
  • 40
  • 34
  • 25
  • 24
  • 23
  • 22
  • 22
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Micro e nanousinagem dos materiais frágeis / Micro e nanomachining of brittle materials

Dib, Marcel Henrique Militão 10 December 2018 (has links)
Materiais frágeis, tal como o silício, têm sido utilizados em sistemas microeletromecânicos, semicondutores e dispositivos ópticos infravermelhos. Estes materiais são considerados de difícil usinabilidade devido à tendência de sofrerem fraturas. O grande desafio na usinagem dos materiais cristalinos é alcançar uma remoção de material por deformações plásticas (regime dúctil), pois, nessas condições as superfícies ópticas usinadas são geradas sem nenhum dano. Esse regime de usinagem pode ser alcançado em escalas submicrométricas, de forma que, em muitos cristais, as pressões impostas pela ferramenta são altas o suficiente para conduzirem uma transformação de fase do material, favorecendo, assim, a usinagem. Embora pesquisas sobre a relação entre a endentação e a usinagem tenham sido desenvolvidas, a busca por métodos matemáticos com base nas forças e deformações de endentação para serem usados em usinagem de modo a identificar as condições ótimas para remoção de material em regime dúctil não são triviais. O presente trabalho propõe uma relação mais direta com os resultados de endentação para determinar os parâmetros ótimos de usinagem dos materiais frágeis, correlacionando a área da face do endentador em contato e a área efetiva da secção de corte em usinagem. Para isso, ensaios de endentação e experimentos de usinagem com ferramenta de diamante foram realizados em escala micro e nanométrica. O material analisado aqui foi o silício monocristalino (100). Uma matriz experimental foi planejada para as possíveis correlações da variação do ângulo de saída da ferramenta e do avanço de usinagem com as áreas de endentação e o surgimento das trincas e fraturas; forças de usinagem e a pressão de transição frágil-dúctil; tensão residual; espessura crítica de corte e o estado das superfícies usinadas. Em relação às durezas obtidas, foi preciso separá-las em dois estágios: antes do surgimento das trincas durante a endentação e depois desse ponto. Durante a usinagem, a melhor remoção de material em regime dúctil foi obtida na direção mais dura do silício. Os ângulos de saída que proporcionaram resultados desfavoráveis em termos de integridade superficial foram o de -25° e ângulos mais negativos que -60°. A pressão de transição se apresentou de 12 GPa a 13 GPa, sendo que as energias específicas de corte seguiram o mesmo comportamento: 9 j/mm³ a 10 j/mm³ respectivamente. A tensão residual se mostrou inversamente proporcional às forças de usinagem. As espessuras crítica-efetivas de corte variaram de 100 nm a 560 nm. Os valores das espessuras críticas de corte estimadas pelos ensaios de endentação variaram de 200 nm a 530 nm. Portanto, foi possível mostrar que os valores de espessura crítica estimados pelo método proposto, com base nos resultados de endentação, corresponderam muito bem às espessuras críticas obtidas nos experimentos de usinagem. Assim sendo, torna-se possível determinar por meio de tal técnica os valores ótimos de usinagem, podendo ser aplicada para qualquer material cristalino. / Brittle materials, such as silicon, have been used in microelectromechanical systems, semiconductor and infrared optical devices. These types of materials are considered of difficult to machine due to the tendency to suffer fractures. The great challenge in the machining of crystalline materials is to achieve a removal of material by plastic deformations (ductile regime), because in these conditions the machined optical surfaces are generated without any superficial damage. This type of machining can be achieved on a submicrometric machining scale, so that the pressures imposed by the tool are high and lead to a phase transformation of many crystals favoring the machining in ductile regime. Although research on the relationship between microindentation and micromachining has been developed, the search for mathematical methods based on the forces and the deformations of indentation to be used in machining in order to identify the machining conditions under regime ductile are non-trivial. The present work proposes a more direct relationship with the results of the indentation to determine the optimal parameters of the fragile materials, correlating the indenter face area and the cutting section effective area in machining. For this purpose, indentation tests and diamond tool machining experiments were carried out on a micro and nanometric scale. The material analyzed here was monocrystalline silicon (100). An experimental matrix was planned for the possible correlations of the variation of the tool rake angle and of the machining feed with the areas of indentation and the beginning of cracks and fractures; cutting forces and the fragile-ductile transition pressure; residual stress; critical cutting thickness and the state of machined surfaces. In relation to the hardness obtained, it was necessary to separate them in two stages: before the emergence of the cracks during the indentation and after that point. During machining, the best removal of ductile material was obtained in the hardest direction of the silicon. The rake angles which gave unfavorable results in terms of surface integrity were -25° and angles more negative than -60°. The transition pressure reached values from 12 GPa to 13 GPa, and the specific shear energies followed the same behavior: 9 j/mm³ at 10 j/mm³ respectively. The residual stress was inversely proportional to the machining forces. Critical-effective uncut thicknesses ranged from 100 nm to 560 nm. The values of the critical uncut thicknesses estimated by the indentation tests ranged from 200 nm to 530 nm. Therefore, it was possible to show that the critical thickness values estimated by the proposed method, based on indentation results, corresponded very well to the critical thickness obtained in the machining experiments. Thus, it is possible to determine by means of such a technique the optimum values of machining, which can be applied to crystalline material.
192

Associação de indicadores da função da membrana celular com o volume de massa tumoral de pacientes com câncer de pulmão não pequenas células. / association of indicators of cell membrane function to the volume of tumor mass in patients wwith lung cancer

Ivany Alves Castanho 30 November 2009 (has links)
O Ângulo de fase (AF), determinado pela bioimpedância (BIA), detecta mudanças em propriedades elétricas dos tecidos se tornando um indicador de prognóstico em diversas doenças crônicas incluindo o câncer de pulmão. Estudos anteriores têm demonstrado associação do AF com a integridade da função da membrana celular. O presente estudo objetivou verificar a possível associação do AF e da razão entre massa extracelular e massa celular corporal (MEC/MCC) com o volume da massa tumoral (VMT) e sobrevida de homens portadores de neoplasia pulmonar do tipo não pequenas células (NPC), comparando este grupo de pacientes com um grupo controle de fumantes ativos sem câncer. Foram avaliados indivíduos do sexo masculino com diagnóstico histopatológico de câncer do pulmão NPC sem tratamento prévio de quimioterapia, radioterapia ou cirurgia (G1=30) e fumantes ativos sem sinais de doença (G2, n=30). A determinação volumétrica da massa tumoral dos pacientes foi através do software Bebúi (Sistema de Análise de Nódulos Pulmonares) e segmentação feita mediante processo semi-automático com o uso de algoritmo de crescimento por região e agregação de voxels. A análise por BIA foi realizada através do aparelho Biodynamics modelo 450. A idade média do G1 foi 65,69,3 anos e G2, 61,58,5 anos. Para a avaliação da capacidade funcional dos pacientes utilizou-se a escala de desempenho Karnofsky Performance Status Scale (KPS). Não houve diferença significativa entre as médias das medidas antropométricas nos dois grupos. No entanto, o AF em média no G1 foi menor em 0,43 (p < 0,05) com a média da razão MEC/MCC maior (1,280,14 p < 0,02) em relação ao G2. Os resultados entre as associações dos indicadores da função celular com o volume de doença foram: AF e VMT (r= - 0,545; p < 0,02);MEC:MCC e o VMT (r= 0,594; p<0,01), AF e KPS (r= 0,44 p= 0,015 ). Foi observada maior sobrevida para os pacientes com o KPS >70% (p < 0,02); AF &#8805; 5,65 (p < 0,04); razão MEC/MCC<1,22 (p< 0,01) e VMT &#8804; 163 ml (p< 0,04). No G2 o AF associou-se com a carga tabágica (r= - 0,54; p < 0,03), apontando possivelmente para as alterações da função celular causadas pela nicotina em fumantes ativos com carga tabágica alta. Nossos resultados, avaliados em conjunto mostram que o AF e a razão MEC/MCC devem ser empregados para avaliar a integridade da função da membrana celular em pacientes com câncer de pulmão NPC no período que antecede o tratamento e que a carga tabágica deve ser considerada como variável importante na avaliação do AF em estudos com indivíduos com ausência de doença. / Phase angle (PA), determined by bioelectrical impedance analysis (BIA), detects changes in electrical properties of the tissues becoming a prognostic indicator in several chronic diseases including lung cancer. This study aimed to verify the possible relationship of AF and the ratio of extracellular mass and body cell mass (ECM/ BCM) with the measure of the volume of the tumor mass and survival of men with lung cancer in non-small cell (NSC), comparing this group of patients with active smokers group control without cancer. We evaluated the males with histopathology diagnosis of lung cancer NSC previously untreated chemotherapy, radiotherapy or surgery (G1 = 30) and active smokers with no signs of disease (G2, n = 30). The volumetric measurement of tumor mass of patients was through software Bebuí (Analysis System of Pulmonary Nodules) and segmentation done by semi-automatic process using a region growing algorithm and aggregation of voxels. The analysis by BIA was performed using the apparatus Biodynamics model 450. The average age of G1 was 65.6 9.3 years and G2, 61.5 8.5 years. For the assessment of functional capacity of patients used the Karnofsky Performance Status Scale (KPS). There was no significant difference between the means of anthropometric measurements in both groups. However, the AF average was lower in G1 at 0.43 (p <0.05) with the mean ratio of ECM / BCM higher (1.28 0.14 p <0.02) compared to G2. The results of the associations between indicators of cellular function with the volume of disease were: PA and VMT (r = - 0.545, p <0.02), MEC/MCC and VMT (r = 0.594, p <0.01), PA and KPS (r = 0.44 p = 0.015). We observed longer survival for patients with KPS> 70% (p <0.02), PA &#8805; 5.65 (p <0.04); reason ECM / BCM <1.22 (p <0.01) VMT and &#8804; 163 ml (p <0.04). PA was associated with the level of smoking (r = - 0.54, p <0.03) in G2, possibly pointing to changes in cellular function caused by nicotine in active smokers with high nicotine load. Our results, evaluated together show that the PA and the reason ECM / MCC should be employed to assess the integrity of the cell membrane in patients with lung cancer NSC in the period before the treatment and that the level of smoking should be considered as variable important in assessing PA in studies with subjects with no disease.
193

PROPRIEDADES TECNOLÓGICAS DA MADEIRA DE Eucalyptus SUBMETIDA A TRATAMENTOS DE CONGELAMENTO E TERMORRETIFICAÇÃO / TECHNOLOGICAL PROPERTIES OF Eucalyptus WOOD SUBJECTED TO FREEZING AND HEAT TREATMENTS

Missio, André Luiz 25 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study aims to investigate chemical, physical, mechanical and surface properties of Eucalyptus grandis and Eucalyptus cloeziana wood subjected to different treatments of freezing and heat. To achieve this, six trees for each specie were used to prepare sample for each mechanical test. The samples were subjected to six thermal treatments. Freezing treatment was performed in a horizontal freezer at -22 ± 2°C for 72 hours, while heat treatment was performed using an oven with force air circulation at 180 and 200 ± 1°C for 3.5 hours. Sampling to perform chemical, physical and surface tests were obtained from samples used in mechanical characterization of wood. Chemical changes were evaluated quantitatively through wet process and qualitatively through infrared spectroscopy (ATR-IR). Physical properties evaluated were: weight loss, specific gravity, equilibrium moisture content, dimensional stability and hygroscopicity of wood. Mechanical evaluation was performed through static bending, impact strength, compression parallel to fibers and Janka hardness. Color and wettability of wood were evaluated using colorimetry and contact angle techniques, respectively. The main findings showed that freezing slightly affected the chemical properties of wood, in which the main changes were found in heat treatments, mainly at 200°C. Freezing improve in weight and equilibrium moisture content of wood, while heat treatment caused weight loss and decrease of equilibrium moisture content of wood. Both heat treatments improved dimensional stability of wood, however when freezing and heat was performed in a combination, they did not showed the best results. Regarding the hygroscopicity of wood, results obtained in heat treatment at 200°C should be highlighted. On the other hand, freezing treatment increased absorption of water. In general, freezing reduced mechanical properties of wood. Heat treatments increased stiffness at static bending and strength at compression parallel to fibers of wood however was responsible for reduction in other mechanical properties. Color of wood was affected mainly for heat treatments, in which a darkening of surface was observed and quantified by decrease of parameter L*. Wettability of wood slightly decreased after heat treatments. Influence of freezing on wettability of wood was related to the natural characteristic of wood from species studied because they did not showed a defined tendency. Therefore, it is believed that treatments performed in this study changed significantly the technological properties of wood. / O presente estudo teve como objetivos investigar as propriedades químicas, físicas, mecânicas e superficiais da madeira de Eucalyptus grandis e Eucalyptus cloeziana submetida a diferentes tratamentos de congelamento e termorretificação. Para tanto, foram confeccionados, a partir de seis árvores de cada espécie, corpos de prova para cada ensaio mecânico. Os corpos de prova foram submetidos a seis tratamentos térmicos. O congelamento foi realizado em um freezer horizontal sob condições de temperatura e tempo de -22 ± 2°C durante 72 horas, enquanto que a termorretificação foi realizada em uma estufa laboratorial com circulação de ar forçada, à 180 e 200 ± 1°C durante 3,5 horas. A amostragem para realização dos ensaios químicos, físicos e superficiais foram provenientes dos corpos de prova utilizados na caracterização mecânica da madeira. As modificações químicas foram avaliadas quantitativamente em ensaios via úmida e qualitativamente por espectroscopia no infravermelho (ATR-IR). As propriedades físicas avaliadas foram a perda de massa e massa específica, teor de umidade de equilíbrio, estabilidade dimensional e higroscopicidade da madeira. Para avaliação das propriedades mecânicas foram realizados ensaios de flexão estática, flexão dinâmica, compressão paralela e dureza Janka. Também foram avaliadas a colorimetria e molhabilidade da madeira, por meio das técnicas de colorimetria e ângulo de contato. Os principais resultados encontrados mostraram que o congelamento pouco afetou as propriedades químicas da madeira, sendo as principais alterações oriundas do processo de termorretificação, principalmente a 200°C. O congelamento causou acréscimos na massa e no teor de umidade de equilíbrio da madeira, enquanto que a termorretificação ocasionou a perda de massa e redução do teor de umidade de equilíbrio. Os dois tratamentos térmicos causaram melhoria na estabilidade dimensional, entretanto, quando combinados, não apresentaram os melhores resultados. Para a higroscopicidade destacam-se os resultados obtidos na termorretificação a 200°C, por outro lado, o congelamento aumentou a absorção de água. De maneira geral, o congelamento causou redução nas propriedades mecânicas da madeira. A termorretificação causou aumento na rigidez a flexão estática e resistência a compressão paralela e redução nas demais propriedades mecânicas. A coloração da madeira foi afetada principalmente pela termorretificação, em que ocorreu um escurecimento superficial, quantificado pelo decréscimo do parâmetro de claridade L*. A molhabilidade da madeira diminuiu sensivelmente após a realização dos tratamentos de termorretificação. A influência do congelamento sobre a molhabilidade foi atribuída a características naturais da madeira das espécies estudadas, sem apresentar tendência definida. Dessa forma, verificou-se que os tratamentos realizados alteraram significativamente as propriedades tecnológicas da madeira.
194

Avaliação dos aspectos morfológicos dos olhos normais e dos olhos com fechamento angular primário antes e após a realização da iridotomia: comparação através da gonioscopia, biometria e biomicroscopia ultra-sônica / Ultrasonographic biomicroscopy, conventional ultrasonography, and gonioscopy exams in normal and primary angle closure eyes before and after laser iridotomy

Lisandro Massanori Sakata 28 October 2005 (has links)
INTRODUÇÃO: O glaucoma de ângulo fechado é reconhecido como uma das principais causas de cegueira mundial. A iridotomia representa o tratamento de eleição nos casos com fechamento angular primário, entretanto, este procedimento pode não ser suficiente para proporcionar abertura do ângulo irido-corneano, controle da pressão intra-ocular (PIO) e estabilização do processo da lesão glaucomatosa. O presente estudo tem como objetivo avaliar a morfologia do segmento anterior do olho em uma amostra de pacientes brasileiros, e realizar uma comparação entre olhos normais (sem sinais de fechamento angular prévio) e olhos com ângulos oclusíveis, antes e após a realização da iridotomia. MÉTODOS: Realizou-se um estudo prospectivo observacional tipo caso-controle em pacientes da Clínica Oftalmológica do HC - FMUSP, onde 40 olhos com ângulos oclusíveis (grupo caso) e 27 olhos normais (grupo controle) foram examinados durante o período de agosto de 2003 a dezembro de 2004. Os pacientes do grupo controle foram pareados por idade, sexo e raça. Os exames de gonioscopia e biometria ultra-sônica foram utilizados para comparar os 27 olhos normais com os 40 olhos com ângulos oclusíveis, antes e após a realização da iridotomia. A biometria ultra-sônica mediu o comprimento axial do olho (CAX), a profundidade da câmara anterior (PCA) e o diâmetro ântero-posterior do cristalino (DAPC). Os 27 olhos do grupo controle foram comparados, através da biomicroscopia ultra-sônica, antes e após a iridotomia com os 31 olhos do grupo caso, que não apresentavam goniosinéquias no quadrante inferior. As imagens da UBM foram obtidas em cortes radiais sobre típicos processos ciliares, no claro e no escuro. A distância da abertura angular a 500?m do esporão escleral (DAA500), profundidade da câmara anterior (PCA-UBM), distância do trabeculado aos processos ciliares (DTPC), espessura da íris a 500?m do esporão escleral (EI500) e distância do esporão escleral à inserção da íris (linha X) foram medidas nas imagens da UBM obtidas às 6 horas. As freqüências de processos ciliares longos sem sulco ciliar e fechamento angular aposicional no escuro também foram determinadas nessas imagens. RESULTADOS: Os parâmetros morfológicos dos 27 olhos do grupo controle apresentaram diferenças significativas quando comparados com os 40 olhos do grupo caso. Os olhos normais apresentaram ângulo irido-corneano mais aberto, menor DAPC e maiores CAX e PCA. Nas imagens da UBM os 27 olhos normais apresentaram maior DAA500, PCA-UBM, linha X, e também, maior DTPC que os 31 olhos com ângulos oclusíveis (651 ± 119 ?m e 508 ± 116 ?m; p < 0.001); porém, a EI500 não apresentou diferença significativa entre os dois grupos. Após a realização da iridotomia foi observado uma abertura significativa do seio camerular, e uma diminuição da freqüência de fechamento angular aposicional nas imagens da UBM obtidas no escuro (28/31 para 16/31). Processos ciliares longos sem sulco ciliar foram observados em 61% (19/31) dos olhos do grupo caso após a iridotomia e em 33% (9/27) dos olhos do grupo controle. CONCLUSÃO: A presença de processos ciliares longos sem sulco ciliar foi um achado comum não somente nos olhos com ângulos oclusíveis como também nos olhos normais. No entanto, nos olhos do grupo caso, os processos ciliares estavam localizados, em média, numa posição mais anterior. Após a iridotomia, mais da metade dos olhos com ângulos oclusíveis continuaram apresentando fechamento angular aposicional na UBM. Os valores preditivos da presença de fechamento angular aposicional (associada ou não a processos ciliares longos sem sulco ciliar) na detecção de pacientes sob risco de apresentarem episódios de fechamento angular precisam ser avaliados em estudos futuros / Introduction: Angle closure glaucoma is emerging as one of the leading cause of worldwide blindness. Laser iridotomy (LI) has been proposed as first line therapy for patients with angle closure, however this procedure may not be effective opening the irido-corneal angle, controlling intra-ocular pressure (IOP) and halting glaucoma progression in all cases. Our study aimed to evaluate anterior segment morphology on a cohort of Brazilian patients comparing normal eyes (no signs of angle closure) to angle closure eyes before and after LI. Methods: In this prospective observational case control study, performed from August of 2003 to December of 2004, we evaluated 40 angle closure eyes and 27 normal control eyes with no signs of angle closure at clinical exam, paired by age, race and gender. We used gonioscopy and A-scan biometry to compare anterior segment morphology of 27 normal control eyes to 40 angle closure eyes of patients from our service, before and after LI. We also used ultrasound biomicroscopy (UBM) exam, to compare 27 normal control eyes to 31 of 40 angle closure eyes with no goniosynachiae at the inferior quadrant evaluated by gonioscopy, before and after LI. Immersion 50-MHz high-frequency ultrasound transducer was used to obtain UBM images in radial scans through a typical ciliary process, in both standard light and dark conditions. A-scan biometry measured axial length (AXL), anterior chamber depth (ACD) and lens thickness (LENS). The angle opening distance at 500?m from the scleral spur (AOD500), trabecular ciliary process distance (TCPD), iris thickness at 500?m and the distance from scleral spur to iris insertion (line X) were measured at UBM images obtained at the inferior quadrant. The frequency of appositional angle closure and the presence of long ciliary process with no ciliary sulcus were also evaluated at UBM images. Results: At gonioscopy and A-scan biometry exam, 27 normal eyes had a significant wider iridocorneal angle opening, a thinner LENS and a greater AXL, ACD than angle closure eyes. At UBM exam, 27 normal control eyes had an significant wider AOD500, line X and also, a longer TCPD than angle closure eyes (651 ± 119 ?m vs. 508 ± 116 ?m; p < 0.001); however no differences were observed in iris thickness between the two groups. After LI, we observed a significant irido-corneal angle opening and the number of angle closure eyes with UBM appositional angle closure in dark condition decreased from 28/31 to 16/31. A long ciliary processes with no ciliary sulcus were observed in 61% (19/31) of angle closure eyes after LI, and also in 33% (9/27) of normal control eyes. Conclusion: A long ciliary processes and absence of ciliary sulcus were a quite common finding not only in angle closure eyes, but also in normal control eyes. However, ciliary processes were located more anteriorly in angle closure eyes. On this cohort of Brazilian patients, more than half of studied eyes submitted to LI maintained UBM appositional angle closure. Whether this apposition with or without long ciliary process and absence of ciliary sulcus detected at UBM images after LI is associated to further goniosynachiae formation and/or loss of IOP control remains to be evaluated
195

Caracterização da alumina anódica porosa modificada por plasma / Characterization of alumina porous anodic modified by plasma

Silva, Karina Rodrigues da 29 June 2015 (has links)
Submitted by Milena Rubi (milenarubi@ufscar.br) on 2016-11-17T17:43:21Z No. of bitstreams: 1 RODRIGUES_Karina_2015.pdf: 7918406 bytes, checksum: 5c7eded70cc8a9dd00ce5c1b2d70d846 (MD5) / Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2016-11-17T17:43:31Z (GMT) No. of bitstreams: 1 RODRIGUES_Karina_2015.pdf: 7918406 bytes, checksum: 5c7eded70cc8a9dd00ce5c1b2d70d846 (MD5) / Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2016-11-17T17:43:39Z (GMT) No. of bitstreams: 1 RODRIGUES_Karina_2015.pdf: 7918406 bytes, checksum: 5c7eded70cc8a9dd00ce5c1b2d70d846 (MD5) / Made available in DSpace on 2016-11-17T17:43:54Z (GMT). No. of bitstreams: 1 RODRIGUES_Karina_2015.pdf: 7918406 bytes, checksum: 5c7eded70cc8a9dd00ce5c1b2d70d846 (MD5) Previous issue date: 2015-06-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / In this study, the wettability of porous anodic alumina (PAA) surfaces modified by plasma was investigated. The porous anodic alumina films were grown on aluminum substrate using a two step anodization procedure in oxalic acid solution under potentiostatic regime. The surfaces of PAA films were modified by plasma treatment or plasma deposition techniques. Prior to surface modification, the impurities were removed by a plasma cleaning procedure. Oxygen was used in plasma treatment in order to produce hydrophilic surfaces. On the other hand, the plasma deposition (in HMDSO or HMDSO + argon mixture) was performed to produce hydrophobic surfaces or less hydrophilic surface. Electropolished aluminum without PAA film were used as reference. The influence of substrate morphology on wettability was analyzed. The morphological characterization was performed by scanning electron microscopy (SEM). The microstructural analysis was carried out using Fourier Transformed Infrared Spectroscopy (FTIR). A goniometer was used to measure the contact angle and evaluate the wettability of electroplished aluminum and PAA films. The results showed that the wettability of the samples was affect by chemical interactions of functional groups on the surface deposited after plasma treatment. The effect of the porous surface morphology on wettability was not significant compared to the plasma treated films with new chemical interactions effects. / Neste trabalho foram investigadas as propriedades de molhabilidade das superfícies nanoestruturadas da alumina anódica porosa (AAP) modificadas por plasma. Os filmes de AAP foram produzidos sobre substrato de alumínio pelo método de anodização potenciostática em duas etapas em solução de ácido oxálico. Após a fabricação, as amostras foram submetidas a um tratamento a plasma (com oxigênio) ou a deposição a plasma (em HMDSO ou em uma mistura de HMDSO e argônio). Antes das modificações das superfícies, removeram-se as impurezas das amostras através de técnicas de limpeza a plasma. No tratamento a plasma, o gás oxigênio foi utilizado para a obtenção de superfícies hidrofílicas. Por outro lado, para tornar a superfície hidrofóbica ou menos hidrofílica, foram feitas duas séries de deposição a plasma, uma contendo uma mistura de argônio e HMDSO e outra série somente com HMDSO. O tratamento ou deposição a plasma também foram feitas em amostras de alumínio eletropolido, sem a camada de AAP, a fim de verificar a influência morfológica do substrato na molhabilidade. A caracterização morfológica dos filmes de AAP foi feita por microscopia eletrônica de varredura (MEV), onde foi verificada a formação dos poros na superfície. A caracterização microestrutural foi feita por espectroscopia de absorção no infravermelho por transformada de Fourier (FTIR) com o objetivo de verificar as alterações químicas na superfície. A molhabilidade foi analisada utilizando um goniômetro, equipamento que realiza medição direta do ângulo de contato. Os resultados mostram que a molhabilidade da superfície é afetada por interações químicas dos grupos funcionais na superfície dos filmes. Por outro lado, o efeito da morfologia sobre a molhabilidade da superfície não é significativo nas condições estudadas.
196

Aperfeiçoamento de um detector de espalhamento de luz laser em baixo ângulo (LALLS in-line) para acompanhamento em tempo real do processo de extrusão / Improvement of a low angle laser light scattering – LALLS detector to access in-line the extrusion process

Gasparini, Thiago Manha 27 February 2015 (has links)
Submitted by Alison Vanceto (alison-vanceto@hotmail.com) on 2017-06-08T17:59:02Z No. of bitstreams: 1 DissTMG.pdf: 5915699 bytes, checksum: 6ec0af39899ad70e102eda93fa21e0e0 (MD5) / Approved for entry into archive by Ronildo Prado (ronisp@ufscar.br) on 2017-06-14T13:47:59Z (GMT) No. of bitstreams: 1 DissTMG.pdf: 5915699 bytes, checksum: 6ec0af39899ad70e102eda93fa21e0e0 (MD5) / Approved for entry into archive by Ronildo Prado (ronisp@ufscar.br) on 2017-06-14T13:48:05Z (GMT) No. of bitstreams: 1 DissTMG.pdf: 5915699 bytes, checksum: 6ec0af39899ad70e102eda93fa21e0e0 (MD5) / Made available in DSpace on 2017-06-14T13:55:25Z (GMT). No. of bitstreams: 1 DissTMG.pdf: 5915699 bytes, checksum: 6ec0af39899ad70e102eda93fa21e0e0 (MD5) Previous issue date: 2015-02-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / The morphology of extruded multiphase polymer systems is usually assessed through off-line characterization methods such as microscopy, which require much time for sample preparation and analysis of the results. This work aimed to the improvement of an optical detector to measure in real time the morphology of blends and polymeric composites in processing by extrusion, by laser light scattering at low angle (LALLS). Such equipment includes hardware and software and is based on measuring the intensity of light from a laser and is spread across and under the melt flow. The signals are collected by an array 91 of photodetectors sent to a computer, and displayed in real time on a three- dimensional plot of scattered light intensity to form a surface defined by 321 points. When analyzing the scattering profile valuable information can be determined that help to elucidate the morphology of the second phase particles. The LALLS detector was tested on bench using standard samples, which were prepared so that one of its parameters (orientation, second phase concentration, dispersed particle size or type of dispersed particle) were known. This allowed the systematic study of these samples and the detector device validation. Finally, the device was tested in real time on the extrusion process, and under different materials and operating conditions. Thus, the LALLS detector device created by the group was improved making it possible to evaluate in a practical way and in real time polymer blends in solid films and morphology of some blends and polymeric composites during extrusion. / A morfologia de sistemas poliméricos polifásicos é usualmente avaliada através de métodos de caracterização off-line, tal como a microscopia, os quais demandam muito tempo para a preparação das amostras e para a análise dos resultados. Este trabalho teve como principal objetivo o aperfeiçoamento de um detector óptico para medida em tempo real da morfologia de misturas e compostos poliméricos no processamento por extrusão, através do espalhamento de luz laser em baixo ângulo (LALLS). Tal equipamento inclui hardware e software e baseia-se na medida da intensidade da luz que provém de um laser e que é espalhada através do material fundido e sob fluxo. Os sinais são coletados por um arranjo de 91 fotodetectores, enviados a um computador, e apresentados em tempo real num gráfico tridimensional da intensidade de luz espalhada formando uma superfície definida por 321 pontos. Ao se analisar o perfil de espalhamento tem-se valiosas informações que ajudam elucidar a morfologia das partículas de segunda fase presentes. O detector de LALLS foi testado em bancada com o uso de amostras-padrão, as quais foram elaboradas de maneira que um de seus parâmetros (orientação, concentração de segunda fase, tamanho de partícula dispersa ou tipo de partícula dispersa) tivesse sido alterado de forma conhecida. Isso permitiu o estudo sistematizado dessas amostras e a validação do dispositivo detector. Por fim, o dispositivo foi testado em tempo real no processo de extrusão, sob diferentes condições materiais e de operação. Com isso, o dispositivo detector de LALLS criado pelo grupo foi aperfeiçoado possibilitando avaliar-se de forma prática e em tempo real: a morfologia de misturas poliméricas na forma de filmes sólidos e algumas misturas e compostos poliméricos durante a extrusão.
197

Associação de indicadores da função da membrana celular com o volume de massa tumoral de pacientes com câncer de pulmão não pequenas células. / association of indicators of cell membrane function to the volume of tumor mass in patients wwith lung cancer

Ivany Alves Castanho 30 November 2009 (has links)
O Ângulo de fase (AF), determinado pela bioimpedância (BIA), detecta mudanças em propriedades elétricas dos tecidos se tornando um indicador de prognóstico em diversas doenças crônicas incluindo o câncer de pulmão. Estudos anteriores têm demonstrado associação do AF com a integridade da função da membrana celular. O presente estudo objetivou verificar a possível associação do AF e da razão entre massa extracelular e massa celular corporal (MEC/MCC) com o volume da massa tumoral (VMT) e sobrevida de homens portadores de neoplasia pulmonar do tipo não pequenas células (NPC), comparando este grupo de pacientes com um grupo controle de fumantes ativos sem câncer. Foram avaliados indivíduos do sexo masculino com diagnóstico histopatológico de câncer do pulmão NPC sem tratamento prévio de quimioterapia, radioterapia ou cirurgia (G1=30) e fumantes ativos sem sinais de doença (G2, n=30). A determinação volumétrica da massa tumoral dos pacientes foi através do software Bebúi (Sistema de Análise de Nódulos Pulmonares) e segmentação feita mediante processo semi-automático com o uso de algoritmo de crescimento por região e agregação de voxels. A análise por BIA foi realizada através do aparelho Biodynamics modelo 450. A idade média do G1 foi 65,69,3 anos e G2, 61,58,5 anos. Para a avaliação da capacidade funcional dos pacientes utilizou-se a escala de desempenho Karnofsky Performance Status Scale (KPS). Não houve diferença significativa entre as médias das medidas antropométricas nos dois grupos. No entanto, o AF em média no G1 foi menor em 0,43 (p < 0,05) com a média da razão MEC/MCC maior (1,280,14 p < 0,02) em relação ao G2. Os resultados entre as associações dos indicadores da função celular com o volume de doença foram: AF e VMT (r= - 0,545; p < 0,02);MEC:MCC e o VMT (r= 0,594; p<0,01), AF e KPS (r= 0,44 p= 0,015 ). Foi observada maior sobrevida para os pacientes com o KPS >70% (p < 0,02); AF &#8805; 5,65 (p < 0,04); razão MEC/MCC<1,22 (p< 0,01) e VMT &#8804; 163 ml (p< 0,04). No G2 o AF associou-se com a carga tabágica (r= - 0,54; p < 0,03), apontando possivelmente para as alterações da função celular causadas pela nicotina em fumantes ativos com carga tabágica alta. Nossos resultados, avaliados em conjunto mostram que o AF e a razão MEC/MCC devem ser empregados para avaliar a integridade da função da membrana celular em pacientes com câncer de pulmão NPC no período que antecede o tratamento e que a carga tabágica deve ser considerada como variável importante na avaliação do AF em estudos com indivíduos com ausência de doença. / Phase angle (PA), determined by bioelectrical impedance analysis (BIA), detects changes in electrical properties of the tissues becoming a prognostic indicator in several chronic diseases including lung cancer. This study aimed to verify the possible relationship of AF and the ratio of extracellular mass and body cell mass (ECM/ BCM) with the measure of the volume of the tumor mass and survival of men with lung cancer in non-small cell (NSC), comparing this group of patients with active smokers group control without cancer. We evaluated the males with histopathology diagnosis of lung cancer NSC previously untreated chemotherapy, radiotherapy or surgery (G1 = 30) and active smokers with no signs of disease (G2, n = 30). The volumetric measurement of tumor mass of patients was through software Bebuí (Analysis System of Pulmonary Nodules) and segmentation done by semi-automatic process using a region growing algorithm and aggregation of voxels. The analysis by BIA was performed using the apparatus Biodynamics model 450. The average age of G1 was 65.6 9.3 years and G2, 61.5 8.5 years. For the assessment of functional capacity of patients used the Karnofsky Performance Status Scale (KPS). There was no significant difference between the means of anthropometric measurements in both groups. However, the AF average was lower in G1 at 0.43 (p <0.05) with the mean ratio of ECM / BCM higher (1.28 0.14 p <0.02) compared to G2. The results of the associations between indicators of cellular function with the volume of disease were: PA and VMT (r = - 0.545, p <0.02), MEC/MCC and VMT (r = 0.594, p <0.01), PA and KPS (r = 0.44 p = 0.015). We observed longer survival for patients with KPS> 70% (p <0.02), PA &#8805; 5.65 (p <0.04); reason ECM / BCM <1.22 (p <0.01) VMT and &#8804; 163 ml (p <0.04). PA was associated with the level of smoking (r = - 0.54, p <0.03) in G2, possibly pointing to changes in cellular function caused by nicotine in active smokers with high nicotine load. Our results, evaluated together show that the PA and the reason ECM / MCC should be employed to assess the integrity of the cell membrane in patients with lung cancer NSC in the period before the treatment and that the level of smoking should be considered as variable important in assessing PA in studies with subjects with no disease.
198

Parâmetros de avaliação nutricional para detectar desnutrição em pacientes com AIDS em tratamento com antirretrovirais / Nutritional assessment parameter to detect malnutrition in Aids patients on retroviral therapy

Carla Alexandra Almeida Salmazo 11 August 2010 (has links)
A avaliação do estado nutricional em pacientes com HIV é de grande importância, pois as conseqüências provocadas pelo processo patológico da doença estão associadas com perda de peso corporal, massa magra e desnutrição grave, o que prediz aumento da morbimortalidade. Os valores de linfometria CD4 também têm sido utilizados como preditores a curto e médio prazo para o desenvolvimento de infecções oportunistas, as quais são incomuns em pacientes com CD4 >200 cels/mm3. Partindo deste conhecimento, optou-se por estudar o estado nutricional de homens e mulheres HIV positivos de acordo com a contagem de células CD4. Utilizou-se como parâmetros nutricionais o índice de massa corporal (IMC), a área muscular do braço corrigida (AMBc), albumina sérica e o ângulo de fase (AF). Foram estudados 39 pacientes HIV positivos, acompanhados pelo ambulatório de doenças infectoparasitárias do Hospital Universitário Pedro Ernesto (HUPE/UERJ). Não foi observada desnutrição na população estudada, quando avaliada pelo IMC e albumina em ambos os sexos, independente do número de células CD4. Entretanto, a AMBc e o AF, tanto nos homens quanto nas mulheres, demonstraram comprometimento nos parâmetros de massa magra. Em relação à associação entre os indicadores nutricionais e o número de células CD4, foi observado correlação significante com a AMBc e a albumina no grupo estudado. A correlação de acordo com o sexo manteve-se significante em ambos os grupos para AMBc e com uma tendência positiva (p=0,06) entre o AF e CD4 no grupo dos homens. Portanto, estes resultados demonstram que para avaliar o estado nutricional, principalmente o compartimento de massa corporal magra de pacientes HIV positivos sob terapia antirretroviral, é preciso utilizar indicadores mais sensíveis, mesmo naqueles pacientes com melhor estado de controle da doença. / The assessment of nutritional status in patients with HIV is of great importance, because the consequences caused by the pathological process of the disease are associated with weight loss, lean body mass and severe malnutrition, which predicts increased morbidity and mortality. The values of CD4 linfometria have also been used as predictors of short and medium term development of opportunistic infections, which are uncommon in patients with CD4 counts > 200 cells/mm3. Based on this knowledge, we chose to study the nutritional status of HIV positive men and women according to CD4 cell count. Participants had the following nutritional parameters assessed: body mass index (BMI), corrected arm muscle area (AMA), serum albumin and the phase angle (PA). We studied 39 HIV-positive patients, under treatment in a infectious diseases clinic of the University Hospital Pedro Ernesto (HUPE). None of patients has malnutrition according BMI and albumin in both sexes, regardless of the number of CD4 cells. However, in men and women to AMA and the PA, have demonstrated reductions in parameters of lean body mass. Regarding the association between nutritional indicators and the number of CD4 cells, we observed a significant correlation with the AMA and albumin in the study group. The correlation according to gender remained significant in both groups for AMA and a positive trend (p = 0.06) between the PA and CD4 in males. Therefore these results demonstrate that to assess nutritional status, especially the compartiment of lean body mass in HIV positive patients under antirretrovirals, it is necessary to use more sensitive, even in patients with the best state of disease control.
199

Estudos de desempenho dinâmico de geradores síncronos de produtores independentes em sistemas de geração distribuída via ATPDraw / Dynamic performance studies of synchronous generators of independent producers in distributed generation systems via ATPDraw

Peres, Larissa Marques 19 July 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work aims to analyze the dynamic performance of a synchronous generator and its controls in a distributed generation system, as well as evaluate the impacts of its operation when connected to the distribution grid, using for this task the ATPDraw interface/tool of software ATP. Within this context, it is firstly necessary to obtain suitable models to represent the synchronous machine control systems (voltage regulator, speed governor and stabilizer system) in ATPDraw. Furthermore, for stability analysis, it is developed a mathematical technique to calculate the machine power angle which is represented in ATPDraw by a device (icon). The adjustments of voltage and speed control system parameters are performed by some adopted procedures which are verified using two electric systems: the first one with a synchronous generator connected to the distribution grid; and the second with three distinct generators forming a multimachine system. In these systems some disturbances are applied such as load shedding and short-circuit to accomplish the studies. Finally, with the previous results, it is carried out some dynamic performance studies of a synchronous generator of an independent producer connected to a distribution grid so as to assess aspects of power quality (voltage magnitude), stability and to evaluate the influence of machine controls during the system response for a given load shedding. / Este trabalho tem como objetivo analisar o desempenho dinâmico de um gerador síncrono e seus controles, num sistema de geração distribuída, assim como avaliar os impactos causados por este quando da sua operação conectado às redes de distribuição, utilizando a interface ATPDraw do software ATP. Neste contexto, é primeiramente necessário obter modelos adequados para representar os sistemas de controle da máquina síncrona (regulador de tensão e regulador de velocidade e estabilizador do sistema) no ATPDraw. Além disso, para análise de estabilidade é desenvolvido uma técnica matemática para o cálculo do ângulo de potência da máquina a qual é representada no ATPDraw por um dispositivo (ícone). Para ajustar os parâmetros dos sistemas de controle de tensão e de velocidade são apresentados alguns procedimentos adotados, sendo estes verificados por meio de dois sistemas elétricos: o primeiro com um gerador síncrono conectado a uma rede de distribuição; e o segundo composto por três geradores distintos formando um sistema multimáquinas. Nesses sistemas são aplicados distúrbios do tipo rejeição de carga e curto-circuito para realização dos estudos. Finalmente, com os resultados obtidos anteriormente, são realizados estudos do desempenho dinâmico de um gerador síncrono de um produtor independente, conectado a rede de distribuição, para avaliar aspectos de qualidade de energia (magnitude de tensão), de estabilidade e verificar as influências dos controles da máquina durante a resposta do sistema para uma dada rejeição de carga. / Mestre em Ciências
200

A reta de Euler e a circunferência dos nove pontos: um olhar algébrico

Souto, Antonio Marcos da Silva 12 August 2013 (has links)
Submitted by Viviane Lima da Cunha (viviane@biblioteca.ufpb.br) on 2015-05-19T14:38:35Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) arquivototal.pdf: 4151214 bytes, checksum: 332991af15a25d2ea7775c9d71ef3216 (MD5) / Approved for entry into archive by Leonardo Americo (leonardo@sti.ufpb.br) on 2015-05-19T15:13:52Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) arquivototal.pdf: 4151214 bytes, checksum: 332991af15a25d2ea7775c9d71ef3216 (MD5) / Made available in DSpace on 2015-05-19T15:13:52Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) arquivototal.pdf: 4151214 bytes, checksum: 332991af15a25d2ea7775c9d71ef3216 (MD5) Previous issue date: 2013-08-12 / This work is the result of a research on the Euler line and the circumference of the nine points. The software geogebra was used to illustrate geometric constructions and present some practical activities for the study of notable points of the triangle, the Euler line and the circumference of the nine points to high school students. However, the work was based on the proof, with the use of Modern Algebra and Linear Algebra, the existence and properties of the object of this research, especially the universal property of points in the plane, critical in these demonstrations. / Este trabalho é o resultado de uma pesquisa sobre a reta de Euler e a circunferência dos nove pontos. Foi utilizado o software geogebra para ilustrar as construções geométricas e apresentar algumas atividades práticas para o estudo dos pontos notá- veis do triângulo, da reta de Euler e da circunferência dos nove pontos aos estudantes do Ensino Médio. Todavia, o trabalho se baseou nas demonstrações, com o uso da Álgebra Moderna e da Álgebra Linear, da existência e das propriedades do objeto desta pesquisa, sobretudo da propriedade universal dos pontos no plano, fundamental nestas demonstrações.

Page generated in 0.0539 seconds