• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 5
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Evaluation de la fiabilité de diodes Laser 1064nm en régime impulsionnel critique pour des applications "seed" de laser à fibre forte puissance / Reliability investigation on 1064nm Laser diodes driven under high-current pulsed conditions for high-power fiber laser seeding applications

Le Galès, Germain 31 March 2017 (has links)
Un nombre croissant d’applications Laser nécessite l’utilisation de sources impulsionnelles présentant une grande modularité en termes de durée, de puissance et de fréquence des impulsions Laser générées. Ces sources s’appuient sur une architecture bien connue, basée sur un amplificateur de puissance à oscillateur maître (MOPA) et intégrée dans un grand nombre de systèmes d’amplification optique. Généralement, elle se compose d’une diode « seed » jouant le rôle d’un oscillateur « source » et pilotée en régime impulsionnel fournissant des impulsions optiques à un étage d’amplification (solide ou fibré), dopé avec des éléments terres rares (ex. Ytterbium). Néanmoins, la puissance crête émise par ce type de diodes dépasse rarement quelques centaines de mW. Afin d’obtenir, en sortie du « MOPA », des impulsions d’une puissance de plusieurs dizaines de kW, il est donc nécessaire de concevoir une chaîne d’amplification optique possédant un gain élevé mais en contrepartie susceptible de générer des phénomènes optiques non-linéaires néfastes à l’application. L’utilisation de diodes Laser monomode commercialisées, à très haute fiabilité, dans des régimes de polarisation en courant crête très élevé mais sous des durées d’impulsion très courtes (très inférieures à 1μs), apparaît comme une solution alternative mais impose d’être validée tant sur le plan de la caractérisation électro-optique de ces diodes que sur la robustesse de leurs performances dans ces régimes critiques de fonctionnement. / A growing number of Laser applications requires the use of pulsed sources with a large versatility in terms of duration, power and frequency of the generated Laser pulses. Such sources are based on the well-established “Master Optical Power Amplifier” architecture, and integrated into a large variety of optical amplification systems. Generally, it is composed of a “seed” diode, acting as a “source” oscillator, operated in pulse regime in order to produce optical pulses forwarded to an amplification stage (solid or fibered), doped with rare earth elements (ex. Ytterbium). However, the maximum output power delivered by such diodes barely reaches a few hundred mW. In order for the “MOPA” to produce output pulses with a peak power reaching a few tens of kW, it is necessary to design an amplification chain with a high optical gain but on the other hand susceptible to generate non-linear phenomena detrimental to the application. The use of commercialized and ultra-reliable single mode Laser diodes, operating in large overcurrent but under short pulse conditions (under 1μs), appears as an alternative solution, which, however, requires to be validated in terms of electro-optical characterizations as well as in terms of performances robustness under these critical conditions.
2

Analysis of Laser Induced Spallation of Electron Beam Physical Vapor Deposited (EB-PVD) Thermal Barrier Coatings

Beeler, David Allen 08 November 2013 (has links)
No description available.
3

Forensic and security applications of a long-wavelength dispersive Raman system

Ali, Esam M.A., Edwards, Howell G.M., Cox, R. 18 February 2015 (has links)
No / A novel dispersive system operating at 1064-nm excitation and coupled with transfer electron InGaAs photocathode and electron bombardment CCD technology has been evaluated for the analysis of drugs of abuse and explosives. By employing near-IR excitation at 1064-nm excitation wavelength has resulted in a significant damping of the fluorescence emission compared to 785-nm wavelength excitation. Spectra of street samples of drugs of abuse and plastic explosives, which usually fluoresce with 785-nm excitation, are readily obtained in situ within seconds through plastic packaging and glass containers using highly innovative detector architecture based upon a transfer electron (TE) photocathode and electron bombarded gain (EB) technology that allowed the detection of NIR radiation at 1064nm without fluorescence interference. This dispersive near-IR Raman system has the potential to be an integral part in the armoury of the forensic analyst as a non-destructive tool for the in-situ analysis of drugs of abuse and explosives. Copyright (c) 2015 John Wiley & Sons, Ltd.
4

Räumlich-zeitliche Dynamik der laserinduzierten Hsp70-Expression in einem humanen Hautexplantatmodell

Konz, Maximilian 29 November 2016 (has links) (PDF)
Die Narbenbildung des Hautorgans stellt für die gegenwärtige Medizin weiterhin eine schwierige Aufgabe dar. Die frühzeitige Beeinflussung des Wundheilungspro- zesses hin zu einer verminderten oder narbenlosen Heilung scheint von entschei- dender Bedeutung. Ein vielversprechender Ansatz ist die präoperative Laserthe- rapie und dadurch erzeugte Hitzeschockantwort. Auf molekulare Ebene kommt es u.a. zur Expression von Hitzeschockproteine. Die vorliegende in-vitro Studie beschäftigte sich mit der laserinduzierten Hochregulation des Hitzeschockproteins 70 in den epidermalen Schichten. Hierfür wurden drei nicht ablative Lasersysteme mit insgesamt 12 verschiedenen Parametereinstellungen verwendet (1.540-nm Er:Glass- , 755-nm Alexandrit-, 1.064-nm Nd:YAG-Laser). Mithilfe eines humanen Hautexplantatmodells sollte unter gleichbleibenden Bedingungen Zeitpunkt und Konzentration der maximal induzierten Hsp70-Expression sowie epidermale Schä- digungen dargestellt werden. In der verfügbaren Literatur waren hierzu nur begrenzt Daten vorhanden. Alle drei Lasersysteme zeigten signifikante Hsp70-Expressionen. Der Zeitpunkt der maximalen Hsp70-Expression konnte zwischen Tag 1 und 3 festgehalten werden. Dabei zeigten die Lasersysteme unterschiedliche Hsp70- Maxima und unterschiedliche Epidermisschädigungen. Die Ergebnisse ließen schlussfolgern, dass eine potenzielle präoperative Narbenprävention tendeziell ein Tag vor dem chirurgischen Eingriff und mit den stärkeren Parametereinstellungen des 1.064-nm Nd:YAG Lasers durchgeführt werden sollte.
5

Räumlich-zeitliche Dynamik der laserinduzierten Hsp70-Expression in einem humanen Hautexplantatmodell

Konz, Maximilian 06 October 2016 (has links)
Die Narbenbildung des Hautorgans stellt für die gegenwärtige Medizin weiterhin eine schwierige Aufgabe dar. Die frühzeitige Beeinflussung des Wundheilungspro- zesses hin zu einer verminderten oder narbenlosen Heilung scheint von entschei- dender Bedeutung. Ein vielversprechender Ansatz ist die präoperative Laserthe- rapie und dadurch erzeugte Hitzeschockantwort. Auf molekulare Ebene kommt es u.a. zur Expression von Hitzeschockproteine. Die vorliegende in-vitro Studie beschäftigte sich mit der laserinduzierten Hochregulation des Hitzeschockproteins 70 in den epidermalen Schichten. Hierfür wurden drei nicht ablative Lasersysteme mit insgesamt 12 verschiedenen Parametereinstellungen verwendet (1.540-nm Er:Glass- , 755-nm Alexandrit-, 1.064-nm Nd:YAG-Laser). Mithilfe eines humanen Hautexplantatmodells sollte unter gleichbleibenden Bedingungen Zeitpunkt und Konzentration der maximal induzierten Hsp70-Expression sowie epidermale Schä- digungen dargestellt werden. In der verfügbaren Literatur waren hierzu nur begrenzt Daten vorhanden. Alle drei Lasersysteme zeigten signifikante Hsp70-Expressionen. Der Zeitpunkt der maximalen Hsp70-Expression konnte zwischen Tag 1 und 3 festgehalten werden. Dabei zeigten die Lasersysteme unterschiedliche Hsp70- Maxima und unterschiedliche Epidermisschädigungen. Die Ergebnisse ließen schlussfolgern, dass eine potenzielle präoperative Narbenprävention tendeziell ein Tag vor dem chirurgischen Eingriff und mit den stärkeren Parametereinstellungen des 1.064-nm Nd:YAG Lasers durchgeführt werden sollte.

Page generated in 0.0353 seconds