• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 18
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 64
  • 38
  • 34
  • 33
  • 29
  • 24
  • 21
  • 21
  • 21
  • 16
  • 13
  • 12
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Characterization of the GATE Monte Carlo platform for non-isocentric treatments and patient specific treatment plan verification at MedAustron - Vienna - Austria / Caractérisation de la plate-forme GATE Monte Carlo pour les traitements non isocentriques et vérification du plan de traitement spécifique au patient chez MedAustron - Vienna - Austria

Elia, Alessio 08 January 2019 (has links)
L'objectif de cette thèse est de développer et de valider une méthode de calcul de dose indépendante afin de soutenir le travail de mise en service intense d'une installation de traitement par faisceaux d'ions légers (LIBT) et de valider le calcul de dose du système de planification de traitement (SP). Le travail porte sur les traitements de protonthérapie et est organisé en collaboration entre le laboratoire CREATIS (Lyon, France) et le centre de thérapie ionique MedAustron - Vienna - Austria (Wiener Neustadt, Autriche). Chez MedAustron - Vienna - Austria, afin d’exploiter une pénombre latérale aiguë du faisceau de protons et d’améliorer la précision des algorithmes de calcul de la dose TPS, l’intervalle entre la fenêtre de la tête de traitement et le patient est réduit en déplaçant le patient vers la tête de traitement. Par conséquent, les traitements non isocentriques doivent être pris en compte avec précision lors de la modélisation ainsi que lors de la phase de validation, car l'éloignement de la cible de l'isocentre de la pièce peut réduire la précision du traitement. Dans cette étude, la paramétrisation du faisceau de crayons à protons suit les recommandations de Grevillot et al. (2011), mais comprenant une description complète de la buse. Un soin particulier est apporté à la modélisation des propriétés du faisceau de crayon dans des conditions non isocentriques, y compris l'utilisation d'un Range Shifter (RaShi). La caractérisation du faisceau de crayon est basée uniquement sur les profils de fluence mesurés dans le profil de dose d’air et de profondeur acquis dans l’eau. De plus, le modèle présenté est calibré en dose absolue sur la base d'un nouveau formalisme produit-zone-dose présenté dans Palmans et Vatnitsky (2016). Finalement, une validation détaillée est effectuée dans l'eau, pour les distributions de doses tridimensionnelles de forme régulière. Plusieurs paramètres couramment exploités en dosimétrie des protons, tels que la distance parcourue, la pénombre distale, la modulation, la taille des champs et la pénombre latérale pour la dosimétrie protonique sont évalués à des fins de validation. Le modèle optique à faisceau de crayon a atteint une précision de l'exigence clinique de 1 mm / 10% et il n'est pas affecté par la complexité des traitements non isocentriques ni par l'utilisation d'un RaShi. Les plages sont reproduites entre 0,2 et 0,35 mm (déviation maximale) sans et avec le décaleur de plage, respectivement. La différence de dose dans les conditions de référence est de 0,5%. La validation de l'administration de la dose en 3D dans l'eau était à 1,2% maximum. La concordance des paramètres distaux et longitudinaux est généralement meilleure que 1 mm. Les résultats obtenus serviront de référence pour la future mise en œuvre clinique du système de calcul de dose indépendant MedAustron - Vienna - Austria. / The goal of this PhD is to develop and validate an independent dose calculation method in order to support the intense commissioning work of a Light Ion Beam Therapy (LIBT) facility, and to validate the Treatment Planning System (TPS) dose calculation. The work focuses on proton therapy treatments and is held as a collaboration between the CREATIS laboratory (Lyon, France) and the MedAustron - Vienna - Austria Ion Therapy Center (Wiener Neustadt, Austria). At MedAustron - Vienna - Austria, in order to exploit a sharp lateral penumbra for the proton beam as well as to improve the accuracy of the TPS dose calculation algorithms, the air gap between the treatment head window and the patient is reduced by moving the patient towards the treatment head. Therefore, non-isocentric treatments have to be accurately taken into consideration during modeling as well as validation phase as moving the target away from the room isocenter may lead to reduced treatment accuracy. In this study, the parametrization of the proton pencil beam follows the recommendations provided in Grevillot et al. (2011), but including a full nozzle description. Special care is taken to model the pencil beam properties in non-isocentric conditions, including the use of a Range Shifter (RaShi). The characterization of the pencil beam is based solely on fluence profiles measured in air and depth dose profile acquired in water. In addition, the presented model is calibrated in absolute dose based on a newly formalism in dose-area-product presented in Palmans and Vatnitsky (2016). Eventually, a detailed validation is performed in water, for three-dimensional regular-shaped dose distributions. Several parameters commonly exploited in proton dosimetry such as range, distal penumbra, modulation, field sizes and lateral penumbra for proton dosimetry are evaluated for validation purposes. The pencil beam optics model reached an accuracy within the clinical requirement of 1mm/10% and it is not affected by the complexity of non-isocentric treatments and the use of a RaShi. Ranges are reproduced within 0.2 and 0.35 mm (max deviation) without and with range shifter, respectively. The dose difference in reference conditions is within 0.5%. The 3D dose delivery validation in water was within 1.2% at maximum. The agreement of distal and longitudinal parameters is mostly better than 1 mm. The obtained results will be used as a reference for the future clinical implementation of the MedAustron - Vienna - Austria independent dose calculation system. As an example of the potential clinical outcome of the presented work, the patient specific quality assurance measurements performed in water have been successfully reproduced within the clinical requirement of 5% accuracy for a few patients.
42

3D short fatigue crack investigation in beta titanium alloys using phase and diffraction contrast tomography / Caractérisation tridimensionnelle des fissures de fatigue courtes dans les alliages de titane métastable (béta) par tomographie en contraste de phase et de diffraction

Herbig, Michael 26 January 2011 (has links)
La tomographie en contraste de diffraction est une nouvelle technique non destructive d'imagerie synchrotron qui caractérise la microstructure et l'orientation des grains dans les matériaux polycristallins en trois dimensions (3D). En la combinant avec la tomographe par contraste de phase. Il est pour la première fois possible d'observer in situ la propagation 3D des fissures de fatigue courtes au sein d'un ensemble de grains entièrement caractérisé (orientation et forme). L'approche combinée, appelée « tomographie tri-dimensionnelle par rayons X des fissures courtes et de la microstructure »(T3DXFM), a été développée sur l’alliage de titane métastable "Beta21S". Une grande partie de ce travail porte sur le développement de la méthodologie T3DXFM. Dans le jeu de données combinées, chaque point de la surface de rupture 3D peut être associé à une structure de données multidimensionnelle contenant des variables décrivant l'orientation des grains, l'orientation locale de la surface de rupture ainsi que l'histoire de la propagation. La méthode utilise un maillage de surface composé de triangles qui décrit la fissure (en d'autres termes: la surface de rupture) dans l'état de propagation mesuré au dernier cycle de fatigue réalisé. Les orientations des grains, les différents fronts de la fissure, les vitesses de croissance locales ainsi que les joints de grains peuvent être visualisés en attribuant des couleurs à ce maillage. Des outils d'extraction des figures de pôle ont été créés et mis en œuvre. Un algorithme a été développé qui est capable de mesurer la vitesse de propagation locale 30 d'une fissure contenant des branchements. / X-Ray Diffraction Contrast Tomography (DCT) is a recently developed, non-destructive synchrotron imaging technique which characterizes microstructure and grain orientation in polycrystalline materials in three dimensions (3D). By combining it with propagation based phase contrast tomography (PCT) it is for the first lime possible to observe in situ the 3D propagation behavior of short fatigue cracks (SFCs) within a set of fully characterized grains (orientation and shape). The combined approach, termed 3D X-ray Tomography of short cracks and Microstructure (3DXTSM), has been developed on the metastable beta titanium alloy "Beta21S". A large part of this work deals with the development of the 3DXTSM methodology. In the combined dataset, each point on the 3D fracture surface can be associated with a multidimensional data structure containing variables describing the grain orientation, the local fracture surface normal and the propagation history. The method uses a surface mesh composed of triangles that describes the crack (in other words: the fracture surface) in the last propagation state measured. Grain orientations, crack fronts, local growth rates and grain boundaries can be visualized by assigning colors to this mesh. The data structure can be interrogated in a number of different ways. Tools for extracting pole figures and pole density distribution functions have been implemented. An algorithm was developed that is capable of measuring the 3D local growth rate of a crack containing branches. The accuracy of the grain boundaries as reconstructed with OCT was evaluated and the elastic constants of Beta21S were determined.
43

Vers des émetteurs de lumière de longueurs d’ondes contrôlées à base de nanostructures InAs/InP / InAs/InP nanostructures with controlled emission wavelength : Toward photonic integrated circuits applications.

Hadj Alouane, Mohamed Helmi 19 June 2013 (has links)
La complexité des systèmes de télécommunications par fibre optique évolue rapidement de façon à offrir plus de bande passante. Comme ce fut le cas pour l’industrie de la microélectronique, l’intégration de composants photoniques avancés est requise pour la production de composants de haute qualité aux fonctions multiples. C’est dans ce contexte, que s’inscrit ce travail qui consiste à contrôler la longueur d’onde d’émission des nanostructures InAs fabriquées dans deux types matrice InP. En effet, le premier volet de ce travail consiste à étudier les îlots quantiques InAs dans une matrice d’InP massif et sera dédié principalement à l’investigation de l’impact de l’interdiffusion sélective sur les propriétés optiques de bâtonnets quantiques (BaQs) élaborées par l’épitaxie par jets moléculaires (EJM). Un prototype d’une source modulable en longueur a été achevé à base de ces hétérostructures. Un modèles théorique qui traite de l’activation et du transfert thermique des porteurs à travers les BaQs de différentes tailles, créés par l’implantation ionique contrôlée a été développé. Les acquits obtenues dans le premier thème nous ont permis d’aborder une deuxième thématique très concurrentielle liée à l’étude des structures à Nanofils (NFs) InP et des hétérostructures à nanofils InAs/InP allant des structures 1D cœur/coquilles aux structures contenant une BQ InAs par nanofil InP par EJM en mode VLS (Vapeur-Liquide-Solide) sur substrat silicium. Nous avons révélé par différentes techniques spectroscopiques (PL, excitation de PL, microPL, PLRT) des propriétés optiques très spécifiques et particulièrement intéressantes : fort rapport surface/volume impactant sur les durées de vie des porteurs photocrés, présence de différentes phases cristallines (Wurtzite et Zinc-blende) au sein d’un même nanofil en fonction des conditions de croissance. Nous avons pu réaliser des couches actives des émetteurs à base de NFs dans lesquels nous avons privilégié la formation de segments d’InAs assimilables à des boîtes quantiques avec une forte localisation spatiale des porteurs et un très fort maintient de la luminescence en fonction de la température. Les mesures de PL montrent que les segments d’InAs émettent dans la gamme 1.3-1.55 µm ce qui montre le potentiel d’applications de ce type de nanofils dans une technologie des télécommunications par fibres optiques. / La complexité des systèmes de télécommunications par fibre optique évolue rapidement de façon à offrir plus de bande passante. Comme ce fut le cas pour l’industrie de la microélectronique, l’intégration de composants photoniques avancés est requise pour la production de composants de haute qualité aux fonctions multiples. C’est dans ce contexte, que s’inscrit ce travail qui consiste à contrôler la longueur d’onde d’émission des nanostructures InAs fabriquées dans deux types matrice InP. En effet, le premier volet de ce travail consiste à étudier les îlots quantiques InAs dans une matrice d’InP massif et sera dédié principalement à l’investigation de l’impact de l’interdiffusion sélective sur les propriétés optiques de bâtonnets quantiques (BaQs) élaborées par l’épitaxie par jets moléculaires (EJM). Un prototype d’une source modulable en longueur a été achevé à base de ces hétérostructures. Un modèles théorique qui traite de l’activation et du transfert thermique des porteurs à travers les BaQs de différentes tailles, créés par l’implantation ionique contrôlée a été développé. Les acquits obtenues dans le premier thème nous ont permis d’aborder une deuxième thématique très concurrentielle liée à l’étude des structures à Nanofils (NFs) InP et des hétérostructures à nanofils InAs/InP allant des structures 1D cœur/coquilles aux structures contenant une BQ InAs par nanofil InP par EJM en mode VLS (Vapeur-Liquide-Solide) sur substrat silicium. Nous avons révélé par différentes techniques spectroscopiques (PL, excitation de PL, microPL, PLRT) des propriétés optiques très spécifiques et particulièrement intéressantes : fort rapport surface/volume impactant sur les durées de vie des porteurs photocrés, présence de différentes phases cristallines (Wurtzite et Zinc-blende) au sein d’un même nanofil en fonction des conditions de croissance. Nous avons pu réaliser des couches actives des émetteurs à base de NFs dans lesquels nous avons privilégié la formation de segments d’InAs assimilables à des boîtes quantiques avec une forte localisation spatiale des porteurs et un très fort maintient de la luminescence en fonction de la température. Les mesures de PL montrent que les segments d’InAs émettent dans la gamme 1.3-1.55 µm ce qui montre le potentiel d’applications de ce type de nanofils dans une technologie des télécommunications par fibres optiques.
44

Tomographie par rayons X : correction des artefacts liés à la chaîne d'acquisition / Artefacts correction in X-ray cone-beam computed tomography CBCT

Wils, Patricia 17 November 2011 (has links)
L'imagerie cone-beam computed tomography (CBCT) est une méthodologie de contrôle non destructif permettant l'obtention d'images volumiques d'un objet. Le système d'acquisition se compose d'un tube à rayons X et d'un détecteur plan numérique. La recherche développée dans ce manuscrit se déroule dans le contexte industriel. L'objet est placé sur une platine de rotation et une séquence d'images 2D est acquise. Un algorithme de reconstruction procure des données volumiques de l'atténuation de l'objet. Ces informations permettent de réaliser une étude métrologique et de valider ou non la conformité de la pièce imagée. La qualité de l'image 3D est dégradée par différents artefacts inhérents à la plateforme d'acquisition. L'objectif de cette thèse est de mettre au point une méthode de correction adaptée à une plateforme de micro-tomographie par rayons X d'objets manufacturés poly-matériaux. Le premier chapitre décrit les bases de la physique et de l'algorithmie propres à la technique d'imagerie CBCT par rayons X ainsi que les différents artefacts nuisant à la qualité de l'image finale. Le travail présenté ici se concentre sur deux types d'artefacts en particulier: les rayonnements secondaires issus de l'objet et du détecteur et le durcissement de faisceau. Le second chapitre présente un état de l'art des méthodes visant à corriger le rayonnement secondaire. Afin de quantifier le rayonnement secondaire, un outil de simulation basé sur des techniques de Monte Carlo hybride est développé. Il permet de caractériser le système d'acquisition installé au laboratoire de façon réaliste. Le troisième chapitre détaille la mise en place et la validation de cet outil. Les calculs Monte Carlo étant particulièrement prohibitifs en terme de temps de calcul, des techniques d'optimisation et d'accélération sont décrites. Le comportement du détecteur est étudié avec attention et il s'avère qu'une représentation 2D suffit pour modéliser le rayonnement secondaire. Le modèle de simulation permet une reproduction fidèle des projections acquises avec le système réel. Enfin, le dernier chapitre présente la méthodologie de correction que nous proposons. Une première reconstruction bruitée de l'objet imagé est segmentée afin d'obtenir un modèle voxélisé en densités et en matériaux. L'environnement de simulation fournit alors les projections associées à ce volume. Le volume est corrigé de façon itérative. Des résultats de correction d'images tomographiques expérimentales sont présentés dans le cas d'un objet mono-matériaux et d'un objet poly-matériaux. Notre routine de correction réduit les artefacts de cupping et améliore la description du volume reconstruit. / Cone-beam computed tomography (CBCT) is a standard nondestructive imaging technique related to the acquisition of three-dimensional data. This methodology interests a wide range of applications. An industrial CBCT system comprises an X-ray source and a flat-panel detector. Radiographic images are acquired during a rotation of the object of interest. A reconstruction algorithm leads to a volumic representation of the object and a post-processing routine assesses its validity. Accurate quantitative reconstruction is needed to perform an efficient diagsnotic. However, it is challenged by the presence of different artefacts coming from the acquisition itself. This thesis aims at analyzing and correcting those artefacts in a context of industrial micro-tomography. After an introduction to the physical and algorithmic background of CBCT, the artefacts are presented. Our study adresses two major artefacts: beam hardening and scatter radiations coming from the object and the detector. The second chapter reports on the state of the art in secondary radiation correction. A simulation model of the CBCT imaging chain is developed in a Monte Carlo environment. This model is designed to be realistic in order to get an accurate insight on the processes contributing to the final image formation. The third chapter focuses on the built and validation of the simulation tool. Monte Carlo methods are exact but prohibitively slow. Consequently, acceleration and optimization techniques are used to speed-up the calculations without loss of accuracy. A layer model of the flat-panel detector gives some insight on its secondary radiation behavior. More specifically, we demonstrate that a 2D description of the detector would be sufficient to compute its contribution. Our projection tool fits well with the real system. Finally, the last chapter describes our iterative correction method. The noisy initial reconstruction is segmented into different materials and densities and fed to the simulation framework. Beam hardening and secondary radiations are corrected via the volume reconstructed from the difference between acquired and simulated projections. This correction method is shown to be effective on both mono-material and poly-material objects.
45

Détection et analyse du mouvement respiratoire à partir d'images fluoroscopiques en radiothérapie / Detection and analysis of respiratory motion from fluoroscopic images in radiotherapy

Grezes-Besset, Louise 09 December 2011 (has links)
Le principe de la radiothérapie est de délivrer le maximum de dose de rayons X à la tumeur en épargnant au mieux les tissus sains environnants. Dans le cas du cancer du poumon, les mouvements respiratoires représentent une difficulté majeure. L’imagerie tomodensitométrique (TDM) 4D fournit des informations de mouvement spécifique à chaque patient qui peuvent servir de base pour la construction de modèles de mouvement respiratoire. La disponibilité dans les salles de traitement d’imageurs tomographiques embarqués sur les accélérateurs linéaires permet une estimation direct du mouvement et offre des informations plus précises. Un tel système d’imagerie permet entre-autre d’acquérir des images fluoroscopiques : ensemble de projections radiographiques 2D acquises au cours du temps et sous le même angle de vue. Notre approche s’intègre dans des systèmes de synchronisation de l’irradiation avec la respiration. Actuellement, cette technique existe en utilisant pour signal de synchronisation soit un signal externe, soit un signal interne issu du mouvement de marqueurs implantés autour de la tumeur. Notre approche permet d’obtenir un signal de synchronisation obtenu à partir de données internes sans marqueurs implantés. Dans ce cadre, nous avons expérimenté, développé puis évalué 3 méthodes de détection du mouvement à partir de séquences fluoroscopiques. Ces méthodes sont basées respectivement sur la variation de l’intensité, l’extraction de la hauteur du diaphragme et le suivi de blocst. A partir d’un algorithme de mise en correspondance de blocs, nous avons étudié l’homogénéité du mouvement apparent et déterminé, sans a priori géométrique, des régions où le mouvement est uniforme. Nous avons ensuite étudié la corrélation entre le signal interne extrait sur des séquences fluoroscopiques, et un signal extrait d’une vidéo-caméra synchronisée aux séquences fluoroscopiques assimilable à un signal externe. Dans une dernière partie, nous proposons d’estimer le mouvement 3D de la tumeur à partir d’un modèle de mouvement a priori élaboré dans une étape de pré-traitement à l’aide d’images TDM 4D et du signal respiratoire acquis dans la salle de traitement. L’intérêt de notre approche est qu’elle ne nécessite pas de marqueurs implantés ce qui la rend moins invasive que de nombreuses autres techniques. D’autre part, nous proposons un suivi 2D donc potentiellement rapide, mais basé sur un modèle 3D sous-jacent permettant ainsi de retrouver le maximum d’information. Cliniquement, notre approche permettrait de réaliser une adaptation quotidienne aux mouvements inter-sessions. Une des limites de notre approche est qu’elle nécessite une prise d’images ionisantes en continue. Un système hybride basée sur la combinaison d’un signal interne et d’un signal externe permettrait de limiter la dose additionnelle. Des efforts supplémentaires sur la réduction du temps de calcul sont encore nécessaires pour espérer guider un traitement par une telle approche. / Radiotherapy consist of locally exposing target tumor cells to ionizing radiation with the aim of causing irreparable damage to their DNA. Respiratory motion introduces uncertainties in radiation therapy fo lung cancer treatment. The main risks are an over-irradiation of soft tissue and under-irradiation of tumor. The principal aim of this work is to provide a contribution to the extraction of quantitative motion parameters which can help to improve treatment planning. Recent developments have led to the routine acquisition of four-dimensional computed tomography (4DCT) and cone-beam computed tomography (CBCT) for the planning and delivery of certain treatment strategies. The availability of these images over the course of treatment make them particularly suited for providing patient-specific motion information and deriving motion models. Cone-beam is mainly use for its 3D capacity with the rotation system. But it can also acquire fluoroscopic sequences : a set of 2D projections acquired during time and under the same angle of projection. Our approach take place in the gating category treatment where the dose delivery is synchronized with respiration. For lung cancer treatment with gated radiotherapy, tracking apparent respiratory motion in fluoroscopic images is an important step. It is frequently realize using implanted marker next to the tumor. The first purpose of this study is to extract respiratory motion during treatment delivery from fluoroscopy images without implanted markers. We developed 3 methods inspired from literature and compared them. These methods are respectively based on variation intensity in the lung, diaphragm motion extraction and block matching. For each method, we obtain a signal correlated to the respiratory motion. In a second part, we study the spatial variation of the motion in the lung. We try to determine regions where the extracted apparent motion is homogeneous and reliable. Using an adapted block-matching algorithm on fluoroscopic sequences, we extracted individual point trajectories in region of interest corresponding to the lung and classified them using the k-means++ clustering algorithm. We then studied the apparent motion separately in each determined region. As a result, we obtained regions with homogeneous motion. In a third part, we are interested in the correlation of internal and external motion. Finally, in the last section, we propose to estimate 3D motion tumor from an a priori motion model obtained with the planning 4DCT and the respiratory signal extracted in the treatment room.
46

Recalage déformable de projections de scanner X à faisceau conique / Deformable registration of cone-beam projections

Delmon, Vivien 29 November 2013 (has links)
Évaluer quantitativement les mouvements d'un patient lors d'un traitement par radiothérapie est un enjeu majeur. En effet, ces mouvements et ces déformations anatomiques induisent une incertitude balistique conduisant les thérapeutes à augmenter les marges de sécurité, ce qui peut empêcher de délivrer une dose suffisante à la région tumorale. Dans le cadre de cette thèse, nous nous sommes intéressés à l'estimation de ces mouvements dans les images obtenues juste avant le traitement par le scanner à faisceau conique. Pour cela, nous avons utilisé des algorithmes de recalage déformable. Dans un premier temps, nous avons cherché à améliorer la modélisation du mouvement respiratoire. Pour cela, nous nous sommes basés sur un modèle utilisant une segmentation de l'intérieur de la cage thoracique afin d'autoriser le glissement des organes internes contre cette dernière, tout en préservant un champ de déformation cohérent. La segmentation de l'intérieur de la cage thoracique est effectuée automatiquement par un algorithme qui prend en paramètres une segmentation des poumons et de la cage thoracique. Les algorithmes permettant de segmenter ces deux régions se sont avérés peu robustes, ce qui nous a poussé à les améliorer. Une fois ces structures bien segmentées, le modèle de transformation souffre d'un inconvénient majeur empêchant son utilisation dans un algorithme de recalage entre des projections 2D et une image 3D. En effet, il nécessite une segmentation 3D de l'intérieur de la cage thoracique dans les 2 images à recaler, ce qui est impossible à obtenir pour la série de projections 2D. Le modèle proposé dans cette thèse permet de contraindre les déformations à représenter des mouvements physiologiquement plausibles, tout en ne nécessitant qu'une seule segmentation de l'image 3D. Dans un deuxième temps, nous avons implémenté un algorithme de recalage 2D/3D utilisant le modèle de déformation proposé afin d'extraire le mouvement respiratoire des projections 2D de l'imageur à faisceau conique. Cet algorithme a été testé sur des images simulées dont les déformations étaient connues. Les résultats étant concluants, nous avons utilisé un algorithme de reconstruction compensée en mouvement dans le but de produire des images 3D sans flou respiratoire sur des données réelles. L'approche proposée permet d'obtenir une connaissance approfondie de l'anatomie du patient et de son mouvement respiratoire le jour du traitement, ce qui ouvre de nouvelles perspectives comme l'adaptation journalière du traitement, le calcul de dose prenant en compte le mouvement respiratoire et la re-planification de traitement. Cette approche de recalage entre une image 3D et des projections 2D est généralisable à d'autres mouvements et d'autres régions anatomiques. / Motion estimation is a challenge in radiotherapy. It requires security margins to account for the incertitude on the tumor position. In this thesis, we address the problem of estimating the motion directly in the treatment room using the cone-beam projections. Firstly, we proposed a new breathing motion model that takes into account the sliding discontinuity between the rib-cage and the lungs. This method uses a segmentation of the inner part of the rib-cage which is obtained by an algorithm that requires the segmentation of the lungs and the rib-cage. The algorithms segmenting these parts were not robust enough and we proposed methods to improve their robustness. Compared to previous methods using this mask, our motion model is more robust to segmentation inconsistencies because it only requires a single mask instead of two consistent masks. Moreover, in case of 2D/3D registration, the computation of the second mask is usually not possible. The proposed model restricts the transformation to physically plausible motions and rely on a single segmentation. Secondly, we proposed a 2D/3D registration algorithm that uses our breathing model to extract motion from the cone-beam projections obtained just before the treatment. This algorithm was tested on simulated data. Then, we applied it to real data to reconstruct motion compensated images to remove motion blur from cone-beam CT. The proposed approach gives access to the patient motion just before the treatment, which can be used to daily adapt the treatment or to compute 4D dose maps. This approach can be used for other motions in other anatomic regions.
47

Design and implementation of a prompt-gamma camera for real-time monitoring of ion beam therapy / Conception et mise en oeuvre d'une caméra Prompt-Gamma pour la surveillance en temps réel de thérapie par faisceau d'ions

Roellinghoff, Frauke 19 March 2014 (has links)
La protonthérapie est une technique prometteuse pour le traitement du cancer, qui se répend de plus en plus. Le pic prononcé de son profil de dose ainsi que la longueur finie du parcours des particules rendent possible un traitement plus ciblé et permettent de mieux éviter d’endommager des tissus sains. Cependant, la précision de l’irradiation s’avère également être le risque principal lors de l’utilisation de cette technique. En effet, une erreur dans la profondeur de pénétration des particules pourrait engendrer des dégâts considérables. A l’heure actuelle, aucune méthode de contrôle n’est systématiquement utilisée pour s’assurer de la qualité du traitement. Dans ce manuscrit, une méthode indirecte de mesure de la distribution de dose, basé sur la détection de gammas prompts émis le long du parcours du faisceau, est étudiée. Deux concepts de caméra collimatée uni-dimensionnelle sont comparés à l’aune de leur utilisation potentielle : une caméra à fentes parallèles et une caméra “knife-edge”. Les deux systèmes sont optimisés par simulations de Monte Carlo et des mesures sont présentés pour valider ces simulations. La comparaison se base sur la précision avec laquelle un décalage dans la chute du profil prompt gamma peut être détecté, la résolution spatiale, le coût et la taille du système. Des recommandations sont émises pour le choix de la meilleure configuration, selon différentes exigeances. Des résultats similaires sont obtenus pour les deux concepts, atteignant une précision de environ 2 mm pour un seul point de “pencil beam” correspondant à 5e7 protons. L’étude se conclue par un tour d’horizon des pistes de recherche futures qui permettraient d’utiliser un système de détection de gammas prompts dans un contexte clinique futur. / Protontherapy is a promising technique for tumor treatment that is becoming more and more widespread. The sharply peaked profile of the dose and the finite particle range allow for very conformal treatment and better sparing of healthy tissue beyond the tumor, but he precise delivery also proves to be the biggest challenge of the technique. Errors in range are a considerable risk in proton therapy and no range monitoring method is currently systematically used for quality control. In this manuscript, an indirect method of measuring the dose distribution, via the detection of secondary prompt gamma radiation emitted along the beam path, is explored. Two different one-dimensional collimated camera concepts, a multi-parallel-slit camera and a knife-edge slit camera are compared with regards to their potential use. Both systems are optimized via Monte Carlo simulation and measurements are presented for validation. The comparison is made on the basis of the precision with which a shift in the prompt gamma profile falloff edge can be retrieved by comparison with a reference profile as well as the spatial resolution, the cost, weight and bulkiness of the system and guidelines are given for choosing the best configuration for different requirements. Similar values can be obtained for both concepts, reaching a precision for the retrieval of the falloff edge of around 2 mm for a single pencil beam spot of 5×107 protons. This study concludes with an outlook on future developments and areas of investigation with the goal of reaching clinical applicability of a prompt gamma detection system.
48

Joint super-resolution/segmentation approaches for the tomographic images analysis of the bone micro-architecture / Approches conjointes de super-résolution / segmentation pour l'analyse des images tomographiques de la micro-architecture osseuse

Toma, Alina 09 March 2016 (has links)
L'analyse de la microstructure osseuse joue un rôle important pour étudier des maladies de l'os comme l'ostéoporose. Des nouveaux scanners périphériques haute résolution (HR-pQCT) permettent de faire des acquisitions de la micro-architecture osseuse in-vivo sur l'homme. Toutefois la résolution spatiale de ces appareils reste comparable à la taille des travées osseuses, ce qui limite leur analyse quantitative. L'objectif de cette thèse est de proposer de nouvelles approches jointes super-résolution/ segmentation pour une analyse quantitative plus fine des images HR-pQCT in-vivo de la structure osseuse trabéculaire. Dans une première étape nous nous sommes concentrés sur des méthodes 2D de super-résolution avec régularisation par variation totale (TV) puis par variation totale d'ordre plus élevé (Higher Degree TV), avec minimisation par un algorithme ADMM (Alternating Direction Method of Multipliers). Ensuite, nous avons proposé une méthode itérative combinant le principe de Morozov et la méthode de Newton pour estimer le paramètre de régularisation TV. Comparé à la méthode UPRE (Unbiased Predictive Risk Estimator), la méthode proposée est plus rapide et ne requiert pas un balayage exhaustif des valeurs des paramètres. Nous avons développé dans une deuxième étape une méthode de super-résolution/segmentation conjointe avec un a priori basé sur la Variation Totale et une relaxation convexe (Tvbox), qui permet d'améliorer les paramètres quantitatifs de l'os et de la connectivité 3D. La méthode a été validée sur des images expérimentales micro-CT déteriorées artificiellement. Finalement, en vue de l'application à des images réelles HR-pQCT, nous nous sommes intéressés à une approche conjointe semi-aveugle super-résolution/segmentation qui vise à estimer à la fois l'image binaire super-résolue et le noyau de convolution. Des résultats sur des images micro-CT et HR-pQCT sont présentés. En conclusion, notre travail montre que les méthodes d'optimisation basées sur la régularisation TV sont prometteurs pour améliorer la quantification de la micro-architecture osseuse sur des images HR-pQCT. / The investigation of trabecular bone micro-architecture provides relevant information to determine the bone strength, an important parameter in osteoporosis investigation. While the spatial resolution of clinical CT is not sufficient to resolve the trabecular structure, the High Resolution peripheral Quantitative CT (HR-pQCT) has been developed to investigate bone micro-architecture in-vivo at peripheral sites (tibia and radius). Despite this considerable progress, the quantification of 3D trabecular bone micro-architecture in-vivo remains limited due to a lack of spatial resolution compared to the trabeculae size. The objective of this thesis is to propose new joint super-resolution/segmentation approaches for improving the quantitative analysis of in-vivo HR-pQCT images of the trabecular bone structure. To begin with, we have investigated 2D super-resolution methods based on Total Variation (TV) and Higher Degree Total Variation (HDTV) and Alternating Direction Method of Multipliers (ADMM) minimization. Afterwards, an iterative method combining the Morozov principle and the Newton method was proposed in order to estimate the TV regularization parameter. The proposed method provides a very good regularization parameter only in few iterations compared with the UPRE method that requires an extensive scanning of parameter values. Furthermore, we have developed a 3D joint super-resolution/segmentation method based on a TV a prior with a convex relaxation (TVbox). The validation of the proposed methods was made on experimental micro-CT bone images artificially deteriorated. The results showed an improvement of the bone parameters and 3D connectivity with the TVbox method. Moreover, we have investigated a semi-blind joint super-resolution/ segmentation approach aiming to estimate both the binary super-resolved image and the assumed Gaussian blurring kernel that is not known for the real HR-pQCT images. Results on micro-CT and HR-pQCT experimental bone images were presented. In conclusion, our work has shown that TV based regularization methods promise to improve the quantification of bone micro-architecture from HR-pQCT images.
49

Scattering correction in cone beam tomography using continuously thickness-adapted kernels / Correction du diffusé en tomographie par une méthode de convolution par noyaux continus

Bhatia 1990-...., Navnina 29 September 2016 (has links)
La tomodensitométrie intégrant une source de rayons X à faisceau divergent et un détecteur grand champ est une technique bien connue dans le domaine de la tomographie industrielle. La nature des matériaux et les épaisseurs traversées conduisent inévitablement à la génération de rayonnement diffusé. Ce dernier est généré par l’objet mais également par le détecteur. La présence de rayonnement parasite conduit à ne plus respecter l’hypothèse de la loi de Beer-Lambert. Par conséquent, on voit apparaitre sur les coupes tomographiques des artefacts de reconstruction comme des streaks, des effets ventouses ou des valeurs d’atténuation linéaire erronée. Par conséquence, on retrouve dans la littérature de nombreuses méthodes de correction du diffusé. Ce travail vise à mettre en point et tester une méthode originale de correction du diffusé. Le premier chapitre de cette étude, dresse un état de l’art de la plupart des méthodes de corrections existantes. Nous proposons, dans le deuxième chapitre, une évolution de la méthode de superposition des noyaux de convolution (Scatter Kernel Superposition). Notre méthode repose sur une description continue des noyaux en fonction de l’épaisseur traversée. Dans cette méthode, les noyaux de diffusion sont paramétrés analytiquement sur toute la plage d'épaisseur. Le procédé a été testé pour des objets à la fois mono-matériaux et poly-matériaux, ainsi que sur des données expérimentales et simulées. Nous montrons dans le troisième chapitre l’importance de la contribution du diffusé détecteur dans la qualité de l’image reconstruite. Mais également l’importance de décrire les noyaux de convolution à l'aide d'un modèle à quatre gaussienne. Les résultats obtenus à partir de données expérimentales prouvent que la correction du diffusé de l'objet seul ne suffit pas pour obtenir une image de reconstruite sans artefacts. Afin de disposer d’une meilleur modélisation du diffusé du détecteur, nous décrivons, dans le dernier chapitre, une méthode basée sur la combinaison de données expérimentales et simulées permettant d’améliorer l’estimation des noyaux de diffusé. / Advanced Cone Beam Computed Tomography (CBCT) typically uses a divergent conebeam source and a large area detector. As a result, there an inevitable increase in the size area of illumination causing an increase in the intensity of X-ray scatter signal, both from the object and the detector. This leads to the violation of prime assumption of reconstruction process which is based on straight line integrals path followed by the photons. Consequently scatter artifacts appear in the reconstruction images as steaks, cupping effect and thus produce wrong reconstruction values. Due to the severity of the reconstruction artifact caused by scatter, many scatter corrections methods have been adopted in literature. The first part of this study, reviews most of the existing scatter correction methods. The effect of scattering becomes more prominent and challenging in case of X-ray source of high energy which is used in industrial Non Destructive Testing (NDT), due to higher scatter to primary ratio (SPR). Therefore, in this study, we propose a continuously thickness-adapted deconvolution approach based on improvements in the Scatter Kernel Superposition (SKS) method. In this method, the scatter kernels are analytically parameterized over the whole thickness range of the object under study to better sample the amplitude and shape of kernels with respect to the thickness. The method is tested for both homogeneous and heterogeneous objects as well as simulated and experimental data. Another important aspect of this study is the comprehensive evaluation of contribution of the detector scatter performed using continuous method by separating the contribution of scatter due to the object and the detector. This is performed by modeling the scatter kernels using a four-Gaussian model. In the first approach, we performed this evaluation based on simulation of kernels from Monte Carlo simulations and the corrections are performed on typical industrial experimental data. The results obtained prove that the scatter correction only due to the object is not sufficient to obtain reconstruction image, free from artifacts, as the detector also scatters considerably. In order to prove this point experimentally and to have a better modeling of the detector, we describe a method based on combination of experiments and simulations to calculate the scatter kernels. The results obtained also prove, the contribution of the detector scattering becomes important and the PSF of the detector is not constant as considered in the studies so far, but it varies to a great extend with the energy spectrum.
50

Correction of scattered radiation in multi-energy radiography and tomography / Correction du rayonnement diffusé en imagerie multi-énergies radiographique et tomographique

Sossin, Artur 24 October 2016 (has links)
L’imagerie à rayons X couplée aux détecteurs résolus en énergie permet de différencier les matériaux présents et d’estimer leurs contributions respectives. Cependant, ces techniques nécessitent des images très précises. La présence du rayonnement diffusé conduit à une perte du contraste spatial et un biais dans l’imagerie radiographique ainsi que des artefacts dans la tomodensitométrie (TDM). L’objectif principal de cette thèse était de développer une approche de correction du rayonnement diffusé adaptée à l’imagerie multi-énergies. Pour réaliser cette tâche, un objectif secondaire a été défini : la conception et la validation d’un outil de simulation capable de fournir des images du diffusé résolu en énergie dans un temps raisonnable. Une fois validé, cet outil a permis d’étudier le comportement du diffusé dans le domaine spatial et énergétique. Sur la base de cette analyse du diffusé, une approche originale dite « Partial Attenuation Spectral Scatter Separation Approach » (PASSSA) adaptée à l’imagerie multi-énergies a été développée. L’évaluation de PASSSA en mode radiographique par des simulations numériques et des mesures expérimentales a révélé des résultats remarquables en termes d’amélioration du contraste d’image et de la réduction du biais induit par la présence du diffusé. De plus, des études de simulation ont permis d’évaluer la performance de l’approche développée dans la TDM, où PASSSA s’est révélée d’être très efficace pour corriger les distorsions in-duites par le rayonnement diffusé. D’autre part, l’amélioration de la performance dans le contexte de la décomposition des matériaux de base en radiographie après avoir appliqué la méthode développée a également été analysée : l’application de PASSSA se traduit par une amélioration substantielle de l’estimation des épaisseurs des matériaux de base. Finalement, sur la base des différents résultats de validation obtenus, une analyse des développements potentiels a été menée. / X-ray imaging coupled with recently emerged energy-resolved photon counting detectors provides the ability to differentiate material components and to estimate their respective thicknesses. However, such techniques require highly accurate images. The presence of scattered radiation leads to a loss of spatial contrast and, more importantly, a bias in radiographic material imaging and computed tomography (CT). Additionally, artifacts are also introduced in the case of the latter. The main aim of the present thesis was to develop a scatter correction approach adapted for multi-energy imaging. In order to achieve this task, a secondary objective was also set. Namely, the conception and validation of a simulation tool capable of providing energy-resolved scatter simulations in a reasonable time. Once validated through simulations and experimentally, this tool gave the ability to study the behavior of scattered radiation both in spatial and energy domains. Based on the conducted scatter analysis, a Partial Attenuation Spectral Scatter Separation Approach (PASSSA) adapted for multi-energy imaging was developed. The evaluation of PASSSA in radiographic mode through simulations and experiments revealed noteworthy results both in terms of image contrast improvement and scatter induced bias reduction. Additionally, simulation studies examined the performance of the developed approach in CT, where PASSSA also proved to be quite effective at correcting scatter induced distortions. Moreover, the performance improvement in the context of basis material decomposition in radiography after applying the designed method was also analyzed. It was concluded that the application of PASSSA results in a substantial improvement in basis material thickness estimation. Finally, based on the obtained simulated and experimental method evaluation results an analysis of perspective developments was also conducted.

Page generated in 0.0208 seconds