• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 210
  • 1
  • Tagged with
  • 212
  • 212
  • 139
  • 78
  • 76
  • 43
  • 41
  • 40
  • 39
  • 38
  • 37
  • 37
  • 30
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Estratégias analíticas para determinação sequencial de metais em vinhos por espectrometria de absorção atômica de alta resolução com fonte contínua por chama

Boschetti, Wiliam January 2012 (has links)
Neste trabalho foi desenvolvido e otimizado um método para determinação sequencial rápida por espectrometria de absorção atômica de alta resolução com fonte contínua por chama (HR-CS FS-FAAS) de metais em amostras de vinhos, produzidos em diferentes regiões do Brasil. As amostras foram obtidas de 8 regiões brasileiras diferentes: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. Os elementos avaliados foram: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb e Sr. Estes metais têm grande importância nas propriedades organolépticas do vinho, assim como para produção de uvas de qualidade. A validação do método foi feita pelo estabelecimento de curvas de calibração, realização de ensaios de recuperação e comparação dos resultados encontrados por HR-CS FS-FAAS com aqueles obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). Padrões aquosos foram utilizados para a calibração e o coeficiente de correlação encontrado, para todos os analitos avaliados, foi maior que 0,9994. A partir das curvas de calibração os limites de detecção foram calculados para cada elemento: 44 μg L-1 para Cu, 5,0 μg L-1 para Li, 20 μg L-1 para Rb, 42 μg L-1 para Mn, 58 μg L-1 para Co, 15 μg L-1 para Sr, 23 μg L-1 para Be, 0,90 mg L-1 para Na, 4,4 mg L-1 para K e 0,92 mg L-1 para Ca. Ensaios de recuperação para cada analito foram realizados, encontrando recuperações entre 91 e 111%. A partir dos resultados encontrados, fazendo-se uso das técnicas de reconhecimento de padrões Análise por Componentes Principais (PCA) e Análise por Agrupamento Hierárquico (HCA) foi observada a formação de 7 grupos distintos, quando empregados os teores de K, Mn, Rb e Sr, dentre os 8 grupos (regiões do Brasil) avaliados. Com este conjunto de informações, portanto, é possível o monitoramento de fraudes e da qualidade do vinho produzido em cada região produtora. / In this work a method has been developed for the determination of metals in wine samples, produced in different regions of Brazil, using high-resolution continuum source fastsequential flame atomic absorption spectrometry (HR-CS FS-FAAS). The samples were obtained from eight different regions: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. The investigated elements were: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb and Sr. These metals are important for the organoleptic properties of wine and for the production of grapes. The method was validated by recovery tests and comparison between the results obtained by HR-CS FS-FAAS and inductively coupled plasma optical emission spectrometry (ICP OES). Aqueous standards were used for calibration and the correlation coefficient found was higher than 0.9994 for all investigated elements. The detection limits were calculated from the calibration curves for each analyte: 44 μg L-1 for Cu, 5.0 μg L-1for Li, 20 μg L-1 for Rb, 42 μg L-1 for Mn, 58 μg L-1 for Co, 15 μg L-1 for Sr, 23 μg L-1 for Be, 0.90 mg L-1 for Na, 4.4 mg L-1 for K and 0.92 mg L-1 for Ca. The recovery tests showed results between 91 and 111%. After method validation the samples were evaluated. With the results obtained and using pattern recognition techniques Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) was possible to find seven different groups, evaluating K, Mn, Rb and Sr concentration values, among the eight original groups (Brazilian regions) evaluated. Finally, using all the information obtained in this work, it’s possible to control frauds and the wine produced quality.
62

Especiação de mercurio em solos contaminados por analise de termodessorção acoplada a absorção atomica

Windmoller, Claudia Carvalhinho 21 July 2018 (has links)
Orientador: Wilson de Figueiredo Jardim / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-21T09:43:18Z (GMT). No. of bitstreams: 1 Windmoller_ClaudiaCarvalhinho_D.pdf: 3136554 bytes, checksum: 5c92be66556b1873f44c96fdda3b07ca (MD5) Previous issue date: 1996 / Doutorado
63

Quantificação e avaliação da bioacessibilidade in vitro de micro e macroelementos em frutas, hortaliças e cereais / Quantification and evaluation of in vitro bioaccessibility of micro and macroelements in fruits, vegetables and cereals

André Luiz Tognon 20 April 2012 (has links)
Os micro e macroelementos são nutrientes essenciais para o correto funcionamento do metabolismo humano, participando direta ou indiretamente de diversas funções metabólicas e estruturais do organismo, tais como cofatores de enzimas, equilíbrio osmótico nas interfaces de membranas biológicas, biossinalização, constituintes de biomoléculas importantes para o organismo, dentre outros. O consumo de frutas, hortaliças e cereais na dieta é uma forma de se obter as necessidades diárias destes nutrientes, uma vez que se trata de um grupo de alimentos ricos nesses elementos. Levando em conta que apenas uma parcela dos nutrientes de um alimento é bioacessível durante a digestão humana, avaliar a bioacessibilidade destes nutrientes é muito importante. Esta pesquisa de mestrado destinou-se a quantificar, por meio de técnicas espectrométricas de absorção atômica, o teor de micro e macroelementos em alimentos dentro do grupo das frutas, hortaliças e cereais (mais e menos conhecidos pela população brasileira em geral), e posteriormente avaliar, por meio de um teste in vitro, a bioacessibilidade destes elementos nos alimentos. Além disso, visando buscar correlações entre os resultados, a composição centesimal e o conteúdo de ácido fítico dos alimentos analisados foram também determinados. A composição centesimal dos alimentos revelou que os pseudocereais amaranto e quinoa são fontes importantes de proteínas para os humanos. No que diz respeito aos cereais, evidenciou-se que o processo de cozimento provoca uma diminuição dos conteúdos totais dos micro e macroelementos determinados na pesquisa, mas também faz com que as porcentagens de bioacessibilidade aumentem consideravelmente em relação aos cereais crus, mostrando que o maior aproveitamento do potencial nutritivo dos cereais analisados no que tange aos micro e macroelementos estudados é obtido quando os cereais estão cozidos. As quantidades totais e bioacessíveis dos elementos nos alimentos permitiram constatar que existe um relacionamento entre a quantidade de um determinado elemento químico necessária na dieta diária dos seres humanos, e a quantidade deste mesmo elemento presente nas frutas, hortaliças e cereais analisados na pesquisa de mestrado, pois para os macroelementos estas quantidades (total e bioacessível) foram, de modo geral, maiores do que as correspondentes quantidades para os microelementos. Além disso, os resultados mostraram que as hortaliças analisadas podem atuar como boas fontes de cálcio (Ca) para a dieta diária dos seres humanos, e que o macroelemento potássio (K) possui as maiores quantidades totais e bioacessíveis, informação que se encontra em concordância com o fato de este elemento (o K) ser fundamental no crescimento de qualquer espécie vegetal, e de que todos os alimentos analisados na pesquisa são provenientes direta ou indiretamente de espécies vegetais. De modo geral observou-se que a quantidade bioacessível dos elementos nos alimentos menos conhecidos é maior ou igual em relação às correspondentes quantidades presentes nos alimentos mais conhecidos pela população brasileira em geral, demonstrando o potencial nutritivo das frutas, hortaliça e cereais menos conhecidos analisados. A determinação do conteúdo de ácido fítico (fitatos) dos alimentos permitiu evidenciar a tendência de que quanto maior o conteúdo de ácido fítico de um alimento, menor a porcentagem de bioacessibilidade mineral (micro e macroelementos). Para os cereais observaram-se algumas contradições a esta tendência, que possibilitaram concluir que a influência do ácido fítico (e seus fitatos) na bioacessibilidade mineral depende das partes dos grãos cereais (pericarpo, endosperma ou gérmen) que alojam as maiores porcentagens do conteúdo total tanto de ácido fítico, quanto dos elementos químicos nutrientes. Além disso, os resultados também permitiram concluir que os fitatos possuem diferentes intensidades de ligação com os cátions dos elementos nutrientes presentes nas amostras alimentares; desse modo, a influência dos fitatos na bioacessibilidade é maior para alguns elementos e menor para outros, dependendo da estabilidade dos complexos mineral-fitatos. Comparando tipo a tipo os alimentos menos conhecidos e os mais conhecidos pela população brasileira em geral, constatou-se que mesmo tendo conteúdos de ácido fítico comparáveis aos alimentos mais conhecidos, nos alimentos menos conhecidos esse conteúdo exerce uma influência menor sobre a bioacessibilidade mineral de forma geral, mostrando que os alimentos menos conhecidos estudados possuem um valor nutricional no que tange aos micro e macroelementos comparável e, em alguns casos, até maior do que os alimentos mais conhecidos. Levando em conta que o ácido fítico (e seus fitatos) também pode apresentar benefícios para a saúde, os resultados permitiram concluir que o amaranto e a quinoa são alimentos com notáveis propriedades nutricionais, pois combinam um significativo conteúdo de ácido fítico com boas quantidades bioacessíveis dos micro e macroelementos determinados na pesquisa de mestrado. / The micro and macroelements are essential nutrients for proper functioning of the human metabolism, directly or indirectly participating in various metabolic functions and structural organization, such as cofactors of enzymes, osmotic equilibrium at the interface of biological membranes, biosignaling, important constituents of biomolecules for body, among others. The consumption of fruits, vegetables and cereals in the diet is a way to obtain the daily requirements of these nutrients, since it is a group of foods rich in these elements. Taking into account that only a portion of the nutrients of a food is bioaccessible during human digestion, assess the bioaccessibility these nutrients is very important. This research aimed to quantify, by means of atomic absorption spectrometric techniques, the micro and macroelements content in foods within of group of fruits, vegetables and cereals (more or less known by Brazilian population in general), and subsequently evaluating, by means of an in vitro test, the bioaccessibility these elements in the food. Furthermore, in order to seek correlations between the results, the percent composition and phytic acid content of foods analyzed were also determined. The percent composition of food revealed that the pseudocereals amaranth and quinoa are important sources of protein for humans. With regard to cereals, it became clear that the cooking process causes a decrease in the total contents of micro and macroelements determined in the research, but also makes the percentages of bioaccessibility increase considerably compared to raw grains, showing that the more nutritional potential of cereals analyzed (in relation to micro and macroelements studied) is obtained when the cereals are cooked. The total and bioaccessibles amounts of elements in foods allowed to observe that there is a relationship between the amount of a chemical element necessary in the daily diet of humans, and the amount of that element present in fruits, vegetables and cereals analyzed in the research, because for the macroelements these quantities (total and bioaccessible) were generally larger than those corresponding to the microelements. Furthermore, the results showed that the vegetables analyzed can act as good sources of calcium (Ca) for the daily diet of humans, and that the macroelement potassium (K) has the largest totals and bioaccessibles quantity, information that is in accordance with the fact of the K be essential in the growth of any plant species, and that all foods analyzed in this research are derived directly or indirectly from plant species. Overall it was observed that the amount bioaccessible of elements in the food less known is equal or greater in relation to the corresponding quantities present in the foods well known by Brazilian population, demonstrating the nutritive potential of fruits, vegetable and cereals less known analyzed. The determination of content of phytic acid (phytates) of foods allowed to evidence the trend of that as higher the phytic acid content of a food, lower the percentage of bioaccessibility mineral (micro and macroelements). For cereals was observed some contradictions to this trend, which allowed to conclude that the influence of phytic acid (and their phytates) in the bioaccessibility mineral depends of part of cereal grains (pericarp, endosperm and germ) that contains the largest percentages of total content of phytic acid and of chemical elements nutrients. Furthermore, the results also showed that the phytate have different intensities of connection with the cations of nutrients elements present in food samples; thus the influence of phytic acid in bioaccessibility is greater for some elements and smaller for other, depending on stability of mineral-phytate complexes. Comparing type by type the foods less and well known by Brazilian population in general, it was found that even with phytic acid content comparable to the most popular foods, in less known foods this content has a minor influence on the mineral bioaccessibility in general, showing that the foods less known studied have a nutritional value in relation to micro and macroelements comparable and, in some cases, greater than the well known foods. Taking into account that the phytic acid (and their phytates) can also bring health benefits, the results showed that amaranth and quinoa are foods with remarkable nutritional properties, since they combine a significant content of phytic acid with good bioaccessibles amounts of micro and macroelements determined in the research.
64

Determinação simultânia de Cd/Pb em cimento usando TI como padrão interno e de Cr/Mn em alumina por espectrometria de absorção atômica com amostragem de suspensão / Simultaneous determination of Cd/Pb in cement using Tl as internal standard and Cr/Mn in alumina by atomic absorption spectrometry with slurry sampling

Alexandre Luiz de Souza 18 September 2007 (has links)
O objetivo desse trabalho foi o desenvolvimento de métodos analíticos para a determinação simultânea de Cd/Pb em cimento e Cr/Mn em alumina por espectrometria de absorção atômica com atomização eletrotérmica (SIMAAS) e amostragem de suspensão. Considerando os erros de amostragem de suspensão e as condições compromissadas impostas para a determinação simultânea, foi também objetivo do trabalho estudar a aplicação de padrão interno para corrigir erros sistemático e aleatório. A viabilidade de se usar o Tl como padrão interno foi explorada na determinação de Cd e Pb em cimento. O uso do padrão interno se baseou na hipótese de que o elemento Tl deveria adsorver quantitativamente sobre as partículas do material em suspensão. Foi feito o estudo térmico dos elementos Cd, Pb e Tl em soluções aquosas e suspensões, na presença e ausência de diferentes modificadores químicos. O melhor modificador químico (5 µg Pd + 3 µg Mg) foi escolhido com base nos gráficos de correlação. As melhores temperaturas de pirólise e atomização para a determinação simultânea de Cd e Pb foram 600°C e 2000°C, respectivamente. A preparação das amostras foi feita com suspensões contendo 30 µg L-1 de Tl em 0,1 % (v v-1) de HNO3 + 0,025 % (m v-1) de Triton X-100. A avaliação da exatidão foi feita com a determinação de Cd e Pb em cimento de construção civil e dentário com análise de solução e análise de materiais de referência de sedimento marinho (MESS1 e BCSS 1) e de rio (Buffalo River, IEAEA 356). Os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD) obtidos foram 0,14 µg L-1 (1,4pg) para o Cd e de 1,2 µg L-1 (12 pg) para Pb. As massas características foram 1,2 pg e 25 pg para Cd e Pb, respectivamente. Na determinação simultânea de Cr e Mn em alumina não foi utilizado padrão interno. O estudo envolveu a obtenção de curvas de pirólise e atomização em presença de diferentes modificadores. Estudos de interferência mostraram que 100 mg L-1 de Al provocaram aumento nos sinais analíticos dos elementos que foi eliminado com o modificador químico NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combinado com 350 µg de Nb. Nessa condição as temperaturas de pirólise e atomização foram 1400°C e 2400°C, respectivamente. As suspensões de alumina foram preparadas em 2 % (v v-1) HNO3. A avaliação da exatidão foi feita com a determinação de Cr e Mn em material de referência de alumina (Alumina Reduction Grade - 699) e os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD), estimados a partir da variabilidade de 20 medidas consecutivas de uma solução contendo 2 % (v v-1) HNO3 foram 0,11 µg L-1 (2,2 pg) para Cr e 0,17 µg L-1 (3,5 pg) para o Mn. As massas características foram 10 pg e 1,3 pg para Cr e Mn, respectivamente. / The aim of this work was the development of analytical methods for the simultaneous determination of Cd/Pb in cement and Cr/Mn in alumina by electrothermal atomic absorption spectrometry (SIMAAS) and slurry sampling. Considering the errors of slurry sampling and the imposed compromissed conditions for the simultaneous determination, it was also the aiming of this work to study the application of internal standard for the sistematic and random errors correction. The viability of using Tl as internal standard was investigated for Cd and Pb determination in cement. The internal standard aplicability was based on the hypothesis of the element Tl would have to adsorver quantitatively on the particles of the material in suspension. The thermal behaviour of Cd, Pb and Tl in aqueous solutions and suspensions was obtained in presence and absence of different chemical modifiers. The best chemical modifier (5 mg Pd + 3 mg Mg) was chosen based on correlation graphs. The pyrolysis and atomization temperatures for the simultaneous determination of Pb were 600°C and 2000°C, respectively. The sample the preparation was made with 30 mg L-1 of Tl in 0,1% (v v-1) of HNO3 + 0.025% (m v-1 of Triton X-100. The evaluation of the accuracy was made with the determination of Cd and Pb in cement, microwave extraction in acid media and analysis of marine sediment reference materials (MESS1 and BCSS 1) and river sediment (Buffalo River, IEAEA 356). The results are concordant at 95% of confidence level using Studen\'s t-test. The detention limits (LD) was 0.14 µg L-1 (1.4 pg) for Cd and 1.2 µg L-1(12 pg) for Pb. The characteristic masses were 1.2 pg and 25 pg for Cd and Pb, respectively. The simultaneous determination of Cr and Mn in alumina was done without internal standard. Pyrolysis and atomization temperaturas were obtained in presence of different modifiers. Studies of interference shown that 100 mg L-1 of Al provoked increase in the analytical signals of Cr and Mn that was eliminated with the chemical modifier NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combined with 350 mg of Nb as permanent chemical modifier. In this condition pyrolysis and atomization temperatures were 1400 °C and 2400 °C, respectively. The alumina suspensions were prepared in 2% (v v-1) HNO3. The evaluation of the accuracy was made with the determination of Cr and Mn in alumina reference material (Reduction Alumina Grating - 699) and the results were concordant at 95 % of the confidence level using Student\'s t-test. The detention limits (LD) were 0.11 µg L-1 (2.2 pg) for Cr and 0.17 µg L-1 (3.5 pg) for Mn. The characteristic masses were 10 and 1.3 pg for Cr and Mn, respectively.
65

Determinação simultânea de manganês/selênio e cobre/zinco em soro sangüíneo por espectrometria de absorção atômica com atomização eletrotérmica.

Paulo Rogério Miranda Correia 10 May 2001 (has links)
Neste trabalho, desenvolveu-se dois métodos analíticos para a determinação multielementar de Mn/Se e Cu/Zn em amostras de soro sangüíneo por espectrometria de absorção atômica com atomização eletrotérmica e detecção simultânea (SIMAAS). O pré-tratamento da amostra foi minimizado e seguiu o princípio do frasco único (diluição da amostra no próprio copo do amostrador automático). Devido à baixa concentração de Mn e Se esperada, as amostras de soro sangüíneo foram diluídas somente 4 vezes para 0,10% m/v Triton X-100 + 1% v/v HNO3. O tratamento térmico eficiente da amostra foi obtido através da utilização de uma mistura oxidante (15% v/v H2O2 + 1% v/v HNO3), que auxiliou na oxidação dos concomitantes orgânicos, e com a utilização da mistura 20 microgramas de Pd + 10 microgramas de Mg como modificador químico, que permitiu aplicar 1200oC durante a etapa de pirólise, favorecendo a eliminação dos concomitantes inorgânicos. Os limites de detecção obtidos foram (Mn=0,43 microgramas/l e Se=3,3 microgramas/l) e as massas características (Mn=11,6 pg e Se=91,7 pg) permitiram realizar essa determinação utilizando 30 microlitros de soro sangüíneo. As elevadas concentrações de Cu e Zn no soro sangüíneo permitiram diluir as amostras em 80 vezes para 0,01% m/v Triton X-100 + 1% v/v HNO3, reduzindo drasticamente a concentração dos concomitantes nas soluções diluídas. A utilização de 700oC durante a etapa de pirólise favoreceu a perda parcial do elemento mais volátil (Zn) e o mini-fluxo de 50 ml/min de Ar durante a atomização reduziu o sinal de ambos os elementos, viabilizando a determinação de Cu/Zn por SIMAAS. Os limites de detecção (Cu=5,0 microgramas/l e Zn=0,045 microgramas/l) e as massas características (Cu=26,5 pg e Zn=2,7 pg) permitiram realizar essa determinação utilizando 20 microlitros de soro sangüíneo.
66

Determinação de arsenio por espectrometria de absorção atomica com geração de hidreto em um sistema de injeção em fluxo

Moretto, Aloisia Laura 01 August 2018 (has links)
Orientador : Solange Cadore / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-01T15:24:27Z (GMT). No. of bitstreams: 1 Moretto_AloisiaLaura_D.pdf: 3816746 bytes, checksum: b5a44236f77a5585330bf6e554d08892 (MD5) Previous issue date: 2001 / Doutorado
67

Emprego de diferentes estrategias para analises em larga escala : screening, extração ultra-sonica e pre-concentração por ponto nuvem

Nascentes, Clesia Cristina 01 August 2018 (has links)
Orientador : Marco Aurelio Zezzi Arruda / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-01T22:32:50Z (GMT). No. of bitstreams: 1 Nascentes_ClesiaCristina_D.pdf: 5775567 bytes, checksum: 72d6173afcd205d832427174e4d1d8bc (MD5) Previous issue date: 2002 / Doutorado
68

Pre-concentração e determinação em linha de arsenio inorganico em aguas usando espectrometria de absorção atomica com geração de hidreto

Bortoleto, Gisele Gonçalves 03 August 2018 (has links)
Orientador: Solange Cadore / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T11:46:45Z (GMT). No. of bitstreams: 1 Bortoleto_GiseleGoncalves_M.pdf: 2661940 bytes, checksum: b73dba6ee93f482c0fcf349a23b27866 (MD5) Previous issue date: 2003 / Mestrado
69

Otimização de metodologia analitica e avaliação da incidencia de cadmio e chumbo em leite humano e alimentos infantis

Oliveira, Adriana Queiroz de 20 July 2005 (has links)
Orientador: Lucia Maria Valente Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-04T15:50:04Z (GMT). No. of bitstreams: 1 Oliveira_AdrianaQueirozde_D.pdf: 1488421 bytes, checksum: 75f4d6ce9d4b87308aa077df2e458ed5 (MD5) Previous issue date: 2005 / Doutorado / Doutor em Ciência de Alimentos
70

Desenvolvimento de métodos analíticos para a determinação de mercúrio e selênio utilizando técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite

Potes, Mariana da Luz January 2018 (has links)
A geração química de vapor (CVG) e a geração fotoquímica de vapor (PVG) são técnicas analíticas empregadas na conversão do analito, presente na fase condensada, em uma espécie volátil, previamente a sua introdução no sistema de detecção. Neste trabalho foram desenvolvidos procedimentos analíticos para a determinação de Hg e Se em amostras biológicas por técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite (GF AAS). A determinação exata e precisa de Hg em amostras de peixe foi possível após a solubilização em hidróxido de tetrametilamônio e adição de n-propanol, como composto orgânico de baixo peso molecular, e detecção por PVG-GF AAS. O método analítico desenvolvido com o emprego da técnica de PVG para a determinação de Se em água de coco por GF AAS resultou em limites de detecção e quantificação de 0,65 μg L-1 e 2,2 μg L-1, respectivamente, os quais foram semelhantes aos obtidos por CVG. Os métodos desenvolvidos para a determinação de Hg e Se por PVG-GF AAS em amostras biológicas são sensíveis, livres de interferência espectral, de baixo custo e representam uma alternativa viável a CVG. / Chemical vapor generation (CVG) and photochemical vapor generation (PVG) are analytical techniques used to convert the analyte into a volatile species in liquid phase, before the introduction into the detection system. In this study, analytical procedures for the determination of Hg and Se in biological samples by vapor generation techniques coupled to graphite furnace atomic absorption spectrometry (GF AAS) were developed. Accurate Hg determination in fish samples was possible after a solubilization in tetramethylammonium hydroxide and adding n-propanol, as low molecular organic compound, using PVG-GF AAS. The developed method for Se determination in coconut water with PVG-GF AAS have resulted in limits of detection and quantification of 0,65 μg L-1 and 2,2 μg L-1, respectively and that were similar with those obtained with CVG. The developed methods for Hg and Se determination in biological samples using PVG-GF AAS are sensitive, free of spectral interference, low-cost, and are a feasible alternative for CVG.

Page generated in 0.0213 seconds