Spelling suggestions: "subject:"ACCNPQ::engenharia""
21 |
Organização do leiaute e do fluxo produtivo de empresa de gerenciamento de resíduos de equipamentos elétricos e eletrônicosPadilha, Daiane Westhpal 23 February 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-16T12:35:08Z
No. of bitstreams: 1
Daiane Westhpal Padilha_.pdf: 2739784 bytes, checksum: 392dc0c8117ea5cb2c898b78f9d8a6fc (MD5) / Made available in DSpace on 2017-05-16T12:35:08Z (GMT). No. of bitstreams: 1
Daiane Westhpal Padilha_.pdf: 2739784 bytes, checksum: 392dc0c8117ea5cb2c898b78f9d8a6fc (MD5)
Previous issue date: 2017-02-23 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / FINEP - Financiadora de Estudos e Projetos / Ministério da Ciência e Tecnologia / PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares / O objetivo da pesquisa foi analisar as formas de gerenciamento implementadas na empresa, estudo de caso, que executava a desmontagem, descaracterização e tratamento de REEE no Vale do Rio dos Sinos, no Rio Grande do Sul. Para o desenvolvimento deste estudo foi necessário organizar, complementar e analisar os dados disponibilizados pela empresa para atender os objetivos específicos relativo ao mapeamento da cadeia pós-consumo relacionada à empresa, para o balanço de massa da empresa. Enquanto que para propor melhorias no leiaute e no fluxo produtivo fez-se medições no prédio e análises no local para depois aplicar a metodologia de Muther (1978). Ao mapear a cadeia de pós-consumo relacionada à empresa identificou-se que 75% dos geradores que descartam REEE junto a empresa estavam localizadas na Bacia Hidrográfica do Rio dos Sinos (BHRS) concentrando-se nos municípios de Novo Hamburgo e São Leopoldo com 52% e 14% do total de resíduos, respectivamente. As atividades econômicas que mais geraram resíduos, dentre os encaminhados para a empresa foram as relativas a indústria de transformação e comércio com representatividade acima de 25%. Ao efetuar o balanço de massa da empresa verificou-se que foram recolhidos 88% de REEE, 9% de resíduos classe II B – não perigosos - inerte e 2% de resíduos classe I - perigosos. Após a segregação dos resíduos verificou-se que a empresa expediu 71% de resíduos classe II B, 26% de REEE saíram inteiros (sem desmontagem) e 3% foram de resíduo classe I. Dentre os REEE, verificou-se que as linhas marrom (11%) e verde (83%) foram as mais representativa, assim como o metal (84%) foi entre os resíduos classe II B o que apresentou maior quantidade dentre os descartados na empresa. Após a segregação dos REEE houve acréscimo de 470% nos resíduos classe II B. Por meio da metodologia SLP (Systematic Layout Planning ou Sistema de Planejamento de Leiaute), fez-se a reorganização do fluxo produtivo e uma proposta de melhorias para o leiaute da empresa, para o qual foi obtido acréscimos nas áreas de armazenamentos de 17% para os REEE, 16% para os resíduos classe II B, 215% para os televisores e monitores. Conclui-se, desta forma, que a metodologia utilizada neste estudo foi adequada no desenvolvimento de melhorias de leiautes da empresa, já que foi possível demonstrar que com a reorganização das áreas internas obteve-se um melhor fluxo no processo produtivo. Palavras-chave: Gestão de resíduos, REEE. Leiute. SLP. / The objective of this research was to analyze the implemented management forms in the company, case study, which carried out the disassembly, decharacterization and treatment of WEEE in Vale do Rio dos Sinos, Rio Grande do Sul. For the development of this study it was necessary to organize, complement and analyze the data segregation of provided by the company. To meet the specific objectives related to mapping of the post-consumer chain related to the company, to the company's mass balance. While in order to propose improvements in the layout and productive flow, measurements were taken in the building and on-site analyzes to later apply Muther's methodology (1978). When mapping the company's post-consumer chain, it was identified that 75% of the generators that dispose WEEE with the company were located in the Bacia Hidrográfica do Rio dos Sinos (BHRS), focused in the cities of Novo Hamburgo and São Leopoldo with 52 % and 14% of total waste, respectively. The economic activities that generated the most waste, among those sent to the company were those related to the manufacturing and trade industry, with a share of more than 25%. When company’s mass balance was perfomed, it was identified 88% of WEEE, 9% of class II B waste - non-hazardous - inert and 2% of class I hazardous waste were collected. After the residue segregation, it was verified that the company shipped 71% of class II B waste, 26% of WEEE were left intact (without disassembly) and 3% were waste class I. Among the WEEE, it was found that brown (11%) and green (83%) lines were the most representative, as metal (84%) was among class II B residues, which presented the highest amount among the discarded items by the company. After the WEEE’s segregation, there was an increase of 470% in class II B waste. Through the Systematic Layout Planning (SLP) methodology, a reorganization of the production flow and a proposal for improvements were made to the company's layout, for which increases were achieved in the storage areas of 17% for WEEE, 16% for Class II B waste, 215% for televisions and screen monitors. It is concluded that the methodology used in this study was suitable for the development of improvements of company layouts, since it was possible to demonstrate that with the reorganization of the internal areas a better flow in the productive process was obtained. Key-words: Waste management. WEEE. Layout. SLP.
|
22 |
Inventário de gases de efeito estufa e emissões evitadas com o gerenciamento de resíduos e cobertura vegetal na Universidade do Vale do Rio dos SinosPreuss, Maicon Junior 23 February 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-19T13:44:14Z
No. of bitstreams: 1
Maicon Junior Preuss_.pdf: 1952274 bytes, checksum: e1ded7f21fc0cf6f809c7203f9d2c1df (MD5) / Made available in DSpace on 2017-05-19T13:44:14Z (GMT). No. of bitstreams: 1
Maicon Junior Preuss_.pdf: 1952274 bytes, checksum: e1ded7f21fc0cf6f809c7203f9d2c1df (MD5)
Previous issue date: 2017-02-23 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares / As emissões de Gases de Efeito Estufa (GEE) têm sido uma das principais fontes de alterações climáticas na Terra desde o século XVII. Para conhecer o perfil das emissões e quantificar as fontes emissoras que mais contribuem para estas alterações, países, organizações e empresas têm desde o início do século XXI adotado a elaboração do Inventário de Gases de Efeito Estufa (IGEE) como ferramenta para compreenderem o perfil de suas emissões de GEE, o volume de emissões que suas atividades geram na atmosfera e direcionar ações para mitigar e controlar as emissões de tais gases. Frente a esta problemática, a presente pesquisa teve por objetivo realizar o Inventário de Gases de Efeito Estufa da Universidade do Vale do Rio dos Sinos, de acordo com todas as atividades e serviços realizados dentro do Campus de São Leopoldo. A metodologia adotada neste estudo utilizou a coleta de dados existentes no Sistema de Gestão Ambiental (SGA) da universidade, de acordo com os parâmetros do Programa Brasileiro GHG Protocol. O estudo demonstrou que no ano de 2015, a Unisinos emitiu 2.706 tCO2e, mensuradas através do seu IGEE. Os resíduos reciclados na universidade evitaram a emissão de 9,7 tCO2e na atmosfera, através do gerenciamento de resíduos da Unisinos. A cobertura vegetal da universidade absorveu 255 tCO2, através do sequestro de carbono dos 20,4 ha de área de preservação permanente (APP). O balanço de GEE mostrou uma compensação de 255 tCO2e pela manutenção da cobertura vegetal, sendo as emissões líquidas 2.451,44 tCO2e. Como conclusão o estudo sugere que ações para o futuro se baseiem na realização de inventários posteriores e na redução de emissões de GEE através da melhoria de eficiência nos processos de consumo de energia elétrica, manutenção de aparelhos de ar-condicionado e redução no número de viagens aéreas. / Greenhouse gas (GHG) emissions have been one of the main sources of climate change on the Earth since the 17th century. In order to know the emission´ profile and quantify the sources of emissions that contributed the most to these changes, countries, organizations and companies have since the beginning of the 21st century adopted the Greenhouse Gas Inventory (GHGI) as a tool to understand the profile of their GHG emissions, the volume of emissions their activities generate in the atmosphere and direct actions to mitigate and control emissions of those gases. Faced with this problem, the present research had as its goal accomplishing the Greenhouse Gas Inventory of the University of Vale do Rio dos Sinos according to all the activities and services carried out within the Campus of São Leopoldo. The methodology adopted in this study used data collection of the University's Environmental Management System (EMS), according to the parameters of the Brazilian GHG Protocol Program. The study showed that in 2015, Unisinos issued 2,706 tCO2e, measured through its GHGI. Recycled waste at the University prevented the emission of 9.7 tCO2e into the atmosphere through waste management at Unisinos. The university's vegetation cover absorbed 255 tCO2, through carbon sequestration in its 20.4 ha of permanent preservation area (PPA). The GHG balance showed a compensation of 255 tCO2e through the vegetal cover maintenance, showing net emissions of 2,451.44 tCO2e. In conclusion, this study suggests that future actions should be based on accomplishment of later inventories and reduction of GHG emissions through improvement of power consumption efficiency, air conditioners maintenance and reduction of air travels.
|
23 |
Efeitos indesejados do crescimento industrial: um estudo de caso no setor metal-mecânicoKoch, Marcos Vinicius 12 January 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-24T14:23:03Z
No. of bitstreams: 2
Marcos Vinicius Koch_.pdf: 787178 bytes, checksum: 7314b814c7005759320ae0ff540f8821 (MD5)
Marcos Vinicius Koch_.pdf: 787178 bytes, checksum: 7314b814c7005759320ae0ff540f8821 (MD5) / Made available in DSpace on 2017-05-24T14:23:03Z (GMT). No. of bitstreams: 2
Marcos Vinicius Koch_.pdf: 787178 bytes, checksum: 7314b814c7005759320ae0ff540f8821 (MD5)
Marcos Vinicius Koch_.pdf: 787178 bytes, checksum: 7314b814c7005759320ae0ff540f8821 (MD5)
Previous issue date: 2017-01-12 / Nenhuma / Toda organização que compete em um mercado deseja crescer. É através deste crescimento que a empresa busca a perpetuação ao longo do tempo, procurando aumentar a sua lucratividade, sendo mais competitiva e rentável. O crescimento carrega consigo uma mudança grande para a organização, desde seus resultados operacionais até as práticas de gestão utilizadas pelas lideranças da empresa. Porém, nem todas as mudanças trazem um resultado positivo em um primeiro momento. Em certos casos, o plano para crescer pode trazer problemas de resultado. Este trabalho utiliza um estudo de caso em uma empresa do ramo metal mecânico da região do Vale do Rio dos Sinos para investigar como as práticas gerenciais podem mitigar os efeitos indesejados do crescimento industrial inesperado. Para isto, foram realizadas entrevistas com as lideranças de diferentes níveis hierárquicos da empresa, buscando-se averiguar como as práticas gerenciais afetam o processo de crescimento. Concluiu-se que os fatores falha de planejamento do processo de crescimento e qualificação das pessoas da empresa são dois pontos centrais deste processo. Também se concluiu que o crescimento sempre é positivo em longo prazo, porém a queda dos resultados em um primeiro momento nada mais significa do que as “dores” relacionadas ao crescimento. / Every organization that competes in a market wants to growth. It is through this growth that the company seeks perpetuation over time, searching to increase its profitability by being more competitive and profitable. Growth carries with it a big change for the organization, from its operational results until management practices used by the company's leaders. However, not all changes bring a positive result at first time. In some cases, the plan to grow can bring about results issues. This paper employs a case study in a metal mechanic company in the Vale do Rio dos Sinos region, seeking to ascertain how management practices can mitigate the unwanted effects of unexpected industrial growth. For this, interviews with the leaders of different hierarchical levels of the company were applied, trying to find out how the practical management affects the process of growth. It was concluded that the failure of planning process of growth and the qualification of the people of the company are two central points in this process. It was also concluded that growth is always positive in the long run, but the problems in results at first is nothing more than the “pain” related to growth.
|
24 |
Tratamento combinado de lixiviado de aterro sanitário e esgoto doméstico utilizando ozônioSchons, Alisson 24 February 2016 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-25T11:43:55Z
No. of bitstreams: 1
Alisson Schons_.pdf: 2733792 bytes, checksum: 704c4ce2631dfdbe7af1fc3c3e324404 (MD5) / Made available in DSpace on 2017-05-25T11:43:56Z (GMT). No. of bitstreams: 1
Alisson Schons_.pdf: 2733792 bytes, checksum: 704c4ce2631dfdbe7af1fc3c3e324404 (MD5)
Previous issue date: 2016-02-24 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / UNISINOS - Universidade do Vale do Rio dos Sinos / O lixiviado de aterro sanitário tem se caracterizado pela alta concentração de matéria orgânica recalcitrante, nitrogênio amoniacal e compostos tóxicos. Compostos orgânicos recalcitrantes são raramente removidos por processos tradicionais de tratamentos de efluentes, o que dificulta o atendimento aos padrões de lançamento de efluentes. Da mesma forma, o descarte do esgoto doméstico gerado pelas comunidades precisa também de tratamentos prévios para não impactar o meio ambiente. Devido às características do esgoto doméstico, com baixas concentrações de matéria orgânica carbonácea e cor em relação ao lixiviado, vem permitindo que o tratamento combinado desses efluentes seja uma alternativa viável. Diante desse quadro, este trabalho visou à avaliação do tratamento combinado de esgoto doméstico da estação de tratamento de efluentes (ETE) da Unisinos e lixiviado bruto do aterro sanitário de São Leopoldo, utilizando ozônio (O3) como agente oxidante. Os efluentes foram tratados na unidade experimental composta por um reservatório com capacidade de até 500L e um reator cilíndrico de PVC com 250 mm de diâmetro e 2,20 m de altura, operando com fluxo ascencional, totalizando um volume de trabalho de 108 L e preenchido em 2/3 do seu volume total com Anel Pall de 1,5”. Realizaram-se três ensaios em bateladas, com duração de cinco horas e três ensaios com duração de duas horas, com diferentes produções de O3 de 8,9; 9,6 e 10,5 g de O3.h-1, aplicados à mistura de 2% de lixiviado de aterro sanitário (LAS) ao esgoto doméstico (2 L de LAS e 158 L de esgoto). Cada ensaio foi realizado em duplicata, sendo monitorados os seguintes parâmetros: Demanda Química de Oxigênio, Demanda Bioquímica de Oxigênio, Cor Aparente e Verdadeira, Turbidez, pH e calculada as taxas de utilização e de perda de O3. Os resultados evidenciaram que o tratamento por O3 pode ser uma alternativa de pré-tratamento de efluentes, obtendo remoções médias de DQO, DBO, CA, CV e Turbidez de até 46%, 51%, 86%, 86% e 81% respectivamente em cinco horas de ensaio e remoções médias de até 23%, 48%, 78%, 76% e 58% respectivamente em duas horas de ensaio. As maiores taxas de remoções foram alcançadas nos ensaios com maiores vazões de O2 e produções de O3 e nas duas primeiras horas de ensaio. Só foi possível o atendimento aos padrões de lançamentos de efluentes exigidos pela legislação vigente, nos ensaios com duração de cinco horas e com a maior produção de O3 e vazão de O2. O sistema de tratamento também contribuiu para uma melhora na biodegradabilidade do efluente se analisada a relação DBO/DQO e cor. Quanto as taxas de utilização e de perda de O3, verificou-se que a maior quantidade consumida de O3, ocorreu para os parâmetros indicativos de matéria orgânica e para os ensaios com a menor produção de O3. / Landfill leachate has been characterized by the high concentration of recalcitrant organic matter, ammoniacal nitrogen and toxic compounds. Recalcitrant organic compounds are rarely removed by traditional effluent treatment processes. In addition, the treatment of the leachate is colloquial to meet the discharge standards of the effluent. Likewise, the domestic sewage disposal generated by the communities also needs previous treatments to avoid impacts on the environment. Due to the characteristics of domestic sewage, with low concentrations of organic carbon in relation to the leachate, it has allowed the combined treatment of these effluents to be a viable alternative. In view of this situation, this work had the objective of evaluating the combined treatment of domestic sewage of (ETP) and the raw leachate of the San Leopoldo landfill using ozone (O3) as an oxidizing agent. Three batch trials were carried out with a scheduled duration of five hours and three trials lasting two hours, with different yields of O3 of 8.9, 9.6 and 10.5 g of O3.h-1, applied to the mixture Of 2% of landfill leachate) For domestic sewage (2L of LAS and 158L of sewage). Each assay was performed in duplicate and the following parameters were monitored: Oxygen Chemical Demand, Biochemical Oxygen Demand, Apparent and True Color, Turbidity, pH and calculated O3 utilization and loss rates. The results showed that the treatment with O3 can be an excellent alternative of pretreatment of effluents, obtaining average removals of COD, BOD, CA, CV and Turbidity of up to 46%, 51%, 86%, 86% and 81 % Respectively. Average test and removal hours of up to 23%, 48%, 78%, 76% and 58%, respectively, in two hours of testing. The highest removal rates were obtained in the tests with higher flows of O2 and yields of O3 and in the first two hours of the test. It was only possible to meet the effluent release standards required by current legislation, in trials with a duration of five hours and with the highest production of O3 and O2. The treatment system also contributed to an improvement in the biodegradability of the effluent if the BOD/COD ratio was analyzed. As for the rates of use and loss of O3, it was verified that the highest amount of O3 occurred for the parameters indicative of organic matter and for the tests with lower production of O3. The higher the O3 production, the higher the O3 loss and the greater oxidant loss may have been due to volatilization in the effluent accumulation reservoir, since there was no gas loss due to Off-gas and the method used Not Detected The residual ozone.
|
25 |
Estudo comparativo de algoritmos de ECC aplicados à memória NAND FlashKondo, Elcio 11 January 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-25T12:10:45Z
No. of bitstreams: 1
Elcio Kondo_.pdf: 2605139 bytes, checksum: bc6eb6e69a381723f69fbce90af22fab (MD5) / Made available in DSpace on 2017-05-25T12:10:45Z (GMT). No. of bitstreams: 1
Elcio Kondo_.pdf: 2605139 bytes, checksum: bc6eb6e69a381723f69fbce90af22fab (MD5)
Previous issue date: 2017-01-11 / Nenhuma / Atualmente vários equipamentos eletrônicos são equipados com memórias NAND Flash para armazenar dados. Essas memórias são controladas através de um circuito integrado com um controlador de memória, que internamente possui um sistema para garantir a integridade das informações armazenadas, os quais são conhecidos por Error Correction Codes (ECC). Os ECCs são códigos capazes de detectar e corrigir erros através de bits redundantes adicionados à informação. Normalmente, os códigos ECC são implementados em hardware dentro do controlador de memória NAND Flash. Neste trabalho comparou-se alguns códigos de ECC utilizados pela indústria, para as comparações utilizou-se os códigos ECC: Hamming, BCH (Bose-Chaudhuri-Hocquenghem) e Reed- Solomon. Sistematicamente realizou-se comparações entre os ECCs selecionados e escolheu-se os dois mais apropriados (BCH e Hamming), os quais foram implementados em linguagem VHDL, o que possibilitou identificar o código com melhor vantagem econômica no uso em memórias NAND Flash. / Nowadays several electronic equipment are using NAND Flash memories to store data. These memories are controlled by an integrated circuit with an memory controller embedded that internally has a system to ensure the integrity of the stored information, that are known as Error Correction Codes (ECC). The ECCs are codes that can detect and correct errors by redundant bits added to information. Usually the ECC codes are implemented on NAND Flash memory controller as a hardware block. On this text ECC codes used by industry, the Hamming code, BCH (Bose-Chaudhuri-Hocquenghem) and Reed-solomon codes were compared.Systemically compare between selected ECCs were done and selected two codes (BCH and Hamming), which were described in VHDL language and allowed to identify the best code with better economical advantage for NAND Flash memories.
|
26 |
Modelo para estimar a geração de resíduos na construção de obras comerciais verticaislima, Giseli barbosa de 12 January 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-06-06T17:03:04Z
No. of bitstreams: 1
Giseli Barbosa de Lima_.pdf: 1516784 bytes, checksum: b62cf6126e2c71668ad61f65afdfbc82 (MD5) / Made available in DSpace on 2017-06-06T17:03:04Z (GMT). No. of bitstreams: 1
Giseli Barbosa de Lima_.pdf: 1516784 bytes, checksum: b62cf6126e2c71668ad61f65afdfbc82 (MD5)
Previous issue date: 2017-01-12 / Nenhuma / A indústria da construção civil tem um papel fundamental em termos econômicos e sociais para o país. Mas do ponto de vista ambiental, é um dos setores que mais se destaca em relação ao consumo de matérias-primas, além de gerar um grande volume de resíduos de construção e demolição. Para evitar ou reduzir a geração destes resíduos é necessário investigar a sua origem, que pode ser desde a fase do projeto até a de produção, e quantificar a geração para o estabelecimento de parâmetros e controle. Neste contexto, este estudo propõe um modelo para estimar a geração de resíduos na construção de obras comerciais verticais, considerando características específicas das construtoras que atuam na região metropolitana de Porto Alegre/RS. O método de pesquisa consiste num estudo de múltiplos casos, utilizando ferramenta de análise estatística. A pesquisa foi realizada em três etapas: 1) levantamento de dados através de variável dependente (geração de resíduos por área construída – m³/m²) e as variáveis independentes (características de projeto arquitetônico e sistema construtivo); 2) tratamento dos dados utilizando regressão linear múltipla; e 3) aplicação do modelo estatístico e análise com ampliação da amostra. Inicialmente a amostra é constituída por dados de 6 obras comerciais verticais de 5 empresas da região metropolitana de Porto Alegre/RS, gerando um modelo estatístico com R² ajustado = 0,967, permitindo explicar 97% da geração de resíduos por área construída em obras com características semelhantes. As variáveis que formam o modelo consistem em: variável dependente “geração de resíduos por área construída” e as variáveis independentes “tipo/total”; “área total construída”; “índice econômico de compacidade” e “sistema construtivo”. A amostra ampliada é formada por 12 obras, incluindo 6 obras residenciais verticais que atuam na região metropolitana de Porto Alegre/RS. Como resultado foi testado um modelo estatístico, formado pela variável dependente e as variáveis independentes. Ao comparar os valores estimados de geração de resíduos (m³/m²) utilizando este modelo é possível observar que o modelo gerado a partir das obras somente do segmento comercial mostra maior aproximação aos valores de geração de resíduos informados pelas empresas construtoras. / The construction industry plays a key role in economic and social terms for the country. But from the environmental point of view, it is one of the sectors that stands out more in relation to the consumption of raw materials, besides generating a large volume of construction and demolition waste. To avoid or reduce the generation of these wastes, it is necessary to investigate their origin, which can be from the project to the production phase, and quantify the generation for the establishment of parameters and control. In this context, this study proposes a model to estimate the generation of residues in the construction of vertical commercial works, considering specific characteristics of the constructors that operate in the metropolitan region of Porto Alegre/RS. The research method consists of a multiple case study using a statistical analysis tool. The research was performed in three stages: 1) data collection through a dependent variable (generation of waste by constructed area - m³/m²) and independent variables (characteristics of architectural design and construction system); 2) data treatment using multiple linear regression; and 3) application of the statistical model and analysis with amplification of the sample. Initially the sample consists of 6 vertical commercial works of 5 companies from the metropolitan region of Porto Alegre/RS, generating a statistical model with adjusted R² = 0.967, allowing to explain 97% of the waste generation by area constructed in works with similar characteristics . The variables that form the model consist of: dependent variable "generation of residues per constructed area" and independent variables "type/total"; "Total built area"; "Economic index of compactness" and "constructive system". The expanded sample consists of 12 works, including 6 vertical residential works that operate in the metropolitan region of Porto Alegre/RS. As a result was tested a statistical model, formed by the dependent variable and the independent variables. When comparing the estimated values of waste generation (m³/m²) using this model it is possible to observe that the model generated from the works only of the commercial segment shows a greater approximation to the values of generation of waste reported by the construction companies.
|
27 |
Avaliação da influência da espessura do revestimento argamassado e do carregamento no comportamento da alvenaria frente a altas temperaturasSouza, Rodrigo Périco de 28 March 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-06-27T15:22:29Z
No. of bitstreams: 1
Rodrigo Périco de Souza_.pdf: 5310630 bytes, checksum: 0e8d009da8a98c6dde8162f1e503ff61 (MD5) / Made available in DSpace on 2017-06-27T15:22:29Z (GMT). No. of bitstreams: 1
Rodrigo Périco de Souza_.pdf: 5310630 bytes, checksum: 0e8d009da8a98c6dde8162f1e503ff61 (MD5)
Previous issue date: 2017-03-28 / itt Performance - Instituto Tecnológico em Desempenho da Construção Civil / Construrohr / Bennter Argamassas / A alvenaria é um dos sistemas construtivos com maior uso no Brasil, dada a disponibilidade dos materiais, conhecimento da técnica e baixo custo. Devido aos programas de aceleração do crescimento no país, foram construídos diversos edifícios habitacionais com o uso deste sistema, com função estrutural. Concomitantemente com esse crescimento, se deu a entrada em vigor da norma de desempenho das edificações habitacionais, a ABNT NBR 15575:2013, que fixa requisitos e critérios mínimos a serem atendidos pela edificação, sendo um deles a segurança contra incêndio nas construções. Nesse cenário, destacam-se algumas lacunas nos estudos técnicos: o comportamento da alvenaria estrutural quando submetida a elevadas temperaturas, a influência do carregamento nas deformações do plano verificadas no sistema vertical de vedação e a influência do revestimento argamassado no comportamento dos painéis frente ao fogo. Objetivando contribuir com esse segmento, este trabalho visou o desenvolvimento de estudo para identificar quais parâmetros afetam o comportamento das alvenarias frente a altas temperaturas. Para tal, foram avaliadas alvenarias constituídas de um mesmo tipo de bloco cerâmico, variando seu revestimento interno (0, 15 e 25 mm de espessura) e externo fixo de 25 mm, em ensaios com e sem aplicação de 10 tf/m. A norma utilizada foi a ABNT NBR 5628:2001, para análise com e sem carregamento, com o emprego de forno normatizado. Destaca-se que os ensaios foram realizados em sistemas de vedação estrutural em tamanho real, de modo que se possa verificar o isolamento térmico, a estanqueidade, a passagem de gases e fumaça, bem como a estabilidade estrutural. Por meio de análise dos resultados obtidos, percebeu-se que há influência da espessura do revestimento em argamassa e do carregamento no comportamento da alvenaria. As paredes com carregamento apresentaram menores deslocamentos horizontais quando comparadas às sem carregamento. Em relação as paredes sem revestimento interno, a redução foi de 25,7%. Nas paredes com 15 mm de revestimento na face exposta, essa redução foi de 58,1% e nas paredes com 25 mm, a redução foi de 41,0%, em relação as paredes sem aplicação de carregamento. Foi percebida, na medida em que se aumentou a espessura do revestimento, um decréscimo nos deslocamentos horizontais fora do plano, passando de 40 mm para 29 mm aos 240 min. Em relação ao revestimento em argamassa, houve uma melhora considerável nas propriedades de isolamento térmico das paredes. As paredes sem carregamento e com revestimento de 25 mm na face interna, apresentaram uma redução de 43,3% na temperatura externa. As paredes com carregamento e revestimento de 25 mm, houve um decréscimo de 23,8%, inclusive modificando seu Tempo de Resistência ao Fogo (TRF). / Masonry is one the most commonly used constructive systems in Brazil, granted the availability of materials, knowledge of the technique and low cost. Due to the growth acceleration programs of the country, several residential buildings were built under this system, with structural function. Concomitant to this movement came into force the housing performance standard, ABNT NBR 15575:2013, which sets requirements and criteria for buildings, among which resides fire safety within buildings. Under this scenario, the following gaps in technical studies are highlighted, the behavior of structural masonry when submitted to high temperatures, the influence of loading on plane deformations found on wall systems, and the influence of mortar coating on the behavior of panels subject to fire. Seeking to contribute to this segment, this study aimed to identify what parameters affect the behavior of masonry concerning high temperatures. For that, masonries constituted of a same ceramic block were evaluated, their internal coating was varied (0, 15 and 25 mm of thickness) and the external was fixed with 25 mm, through tests with and without application of loading of 10 tons force per meter. The standard ABNT NBR 5628:2001 was used for this analysis, with and without loading, using a standardized oven. It should be noted that the tests were performed on real scale structural wall systems, thus allowing for the verification of thermal insulation, leak-tightness, passing of gasses and smoke, as well as structural stability. From the results, it was noticed that there is influence of the thickness of mortar coating and the loading on the behavior of the masonry. The walls with loading presented smaller deformations in comparison with those without loading. Comparing the walls without internal coating, the reduction was of 27.5%. The walls with 15mm of coating on the external wall displayed a reduction of 58.1% and the walls with 25 mm, a reduction of 41.0%. It was observed that, as the coating thickness increased, the plane deformations decreased, passing from 40 mm to 29 mm by the 240 min. Regarding mortar coating, the thermal insulation properties of the walls were improved significantly. The walls without lading and with coating of 25 mm on the internal face presented a reduction of external temperature of 43.3%. The walls with loading and coating of 25 mm indicated a decrease of 23.8%, as well as a modification of their FRS.
|
28 |
Proposição de um método sistêmico para melhoria da cooperação interdepartamental de uma empresa de manufatura do ramo metal mecânicoMachado, Mateus dos Santos 25 June 2015 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-07-05T11:56:51Z
No. of bitstreams: 1
Mateus dos Santos Machado_.pdf: 8433080 bytes, checksum: e3816a888412ffa8a74d5ff6cbcde2aa (MD5) / Made available in DSpace on 2017-07-05T11:56:51Z (GMT). No. of bitstreams: 1
Mateus dos Santos Machado_.pdf: 8433080 bytes, checksum: e3816a888412ffa8a74d5ff6cbcde2aa (MD5)
Previous issue date: 2015-06-25 / Nenhuma / Se uma organização é composta por diversas partes que trabalham por um objetivo comum, segue-se que a existência de cooperação entre essas diversas partes é essencial para o funcionamento da empresa. Apesar disso, evidências empíricas mostram que a cooperação é um problema para muitas organizações. Embora reconheça a importância da cooperação no mundo corporativo, a literatura atual carece de métodos que indiquem como alcançá-la. Nesse contexto, a presente pesquisa tem como objetivo propor um método sistêmico para analisar o sistema de indicadores e os modelos mentais, visando à melhoria da cooperação interdepartamental em uma empresa de manufatura do ramo metal mecânico. O método de pesquisa abordado foi a Design Science Research, que se caracteriza por ser um processo que usa o conhecimento para projetar artefatos. Tal método é orientado à solução de problemas específicos, não necessariamente à solução ótima, mas à solução satisfatória para a situação. Inicialmente, conceitua-se a problemática envolvida no estudo, constrói-se o referencial teórico com abordagem dos principais tópicos para o desenvolvimento da pesquisa e, posteriormente, evidencia-se o método desenvolvido. Na sequência, descreve-se a aplicação do método em uma empresa de manufatura de grande porte do ramo metal mecânico. Ao final, realiza-se uma avaliação, buscando evidências quanto à efetividade do método aplicado no que tange ao atendimento dos objetivos. Os resultados obtidos, as aprendizagens relatadas e os depoimentos dos participantes indicam que o método proposto permite a proposição de ações para a melhoria da cooperação interdepartamental, que é abordada de modo sistêmico. / If an organization is made up of several parts working towards a common goal, it is assumed that the cooperation among the several parts of the organization is essential for its operation. Nevertheless, empirical evidence shows that cooperation is an issue for many organizations. While acknowledging the importance of cooperation for the organizations, the current literature lacks methods that indicate how to reach it. In this context, this research aims to propose a systemic method for analyzing the system of indicators and mental models aimed at improving interdepartmental cooperation in a manufacturing company at the mechanical metal industry. The method approach used was Design Science Research, which is characterized as a process that uses knowledge to design artifacts aimed at the solution of specific problems, not necessarily the optimal solution, but a satisfactory solution to the situation. Firstly, the problems involved in this study were conceptualized, following the theoretical framework with the approach of the main topics for the research development, as the method is sketched and later applied at a large manufacturing company of the mechanical metal industry. At the end, an assessment was made, seeking evidence of the applied method and its effectiveness to meet the objectives. The results, reported improvement and the testimony of the participants indicate that the proposed method allows us to propose actions to enhance interdepartmental cooperation as it is approached systemically.
|
29 |
Análise das condições de conforto térmico e a influência da renovação de ar em salas de aula de estudantes universitáriosArenhardt, Nilmar Luís 18 May 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-08-09T11:35:59Z
No. of bitstreams: 1
Nilmar Luís Arenhardt_.pdf: 2851510 bytes, checksum: bd406be47f89d12c8e8db0289ab9dbb8 (MD5) / Made available in DSpace on 2017-08-09T11:36:00Z (GMT). No. of bitstreams: 1
Nilmar Luís Arenhardt_.pdf: 2851510 bytes, checksum: bd406be47f89d12c8e8db0289ab9dbb8 (MD5)
Previous issue date: 2017-05-18 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Apesar de muitas vezes as condições climáticas serem favoráveis para alcançar o conforto térmico em edificações que operam com o uso da ventilação natural, o número de edifícios que recorrem ao resfriamento mecânico, por exemplo aos condicionadores de ar, como principal estratégia de climatização tem aumentado consideravelmente. Além de problemas devido ao elevado consumo de energia, alguns estudos apontam que essa situação pode proporcionar uma má qualidade do ar interior, o que para o caso de ambientes de ensino pode ser gravemente prejudicial. Em contrapartida, o uso da ventilação mecânica pode gerar um efeito significativo no resfriamento interno com um consumo inferior de energia e com melhores taxas de renovação de ar. Sendo assim, este trabalho tem como objetivo principal analisar a influência da renovação de ar no conforto térmico de estudantes universitários, comparando resultados de medições de campo e de pesquisas subjetivas em salas de aula com ventilação natural e uma sala com sistema de ventilação mecânica. Os experimentos de campo foram realizados em salas do campus da Universidade do Vale do Rio dos Sinos (Unisinos) em São Leopoldo-RS, com ênfase na estação mais quente do ano. Os dados foram coletados a partir de medições ambientais realizadas concomitantemente às pesquisas subjetivas, que foram realizadas por meio de um questionário entregue aos estudantes, ocupantes dos ambientes avaliados, resultando em um total de 616 questionários. As análises foram realizadas a partir das informações obtidas, sendo os resultados apresentados em forma de gráficos e tabelas, através do cruzamento entre os dados microclimáticos e as respostas dos usuários. Os resultados mostraram que a sensação térmica dos ocupantes da sala com sistema de ventilação mecânica foi mais satisfatória quando comparados aos usuários das demais salas avaliadas. Em relação a aceitabilidade térmica nos dias de avaliação comparativa, 72,5% dos ocupantes da sala com maior renovação de ar classificaram o ambiente como “aceitável” e 27,5% como “inaceitável”. Nas demais salas apenas 40% dos ocupantes classificaram o ambiente como “aceitável” e 60% como “inaceitável”. O estudo também mostrou, para os meses da estação mais quente, uma melhor aplicabilidade do modelo de conforto adaptativo na sala de aula com índices mais elevados de vazão de ar externo. Os resultados encontrados evidenciam ainda que o aumento da taxa de renovação de ar na sala de aula proposta, em conjunto com as ações adaptativas dos ocupantes, proporcionou melhores condições de conforto térmico quando comparada às salas com ventilação natural. / Although many times the climate conditions are appropriate to achieve thermal comfort in buildings that operate with natural ventilation, the number of buildings that apply mechanical cooling, for example the air conditioning, as main climatization strategy have increased considerably. Besides problems in consequence to the elevated energy consumption, some studies show that this situation can provide a bad indoor air quality (IAQ), which in case of teaching environments can be seriously harmful. On the other hand, the use of mechanical ventilation can generate a significant effect at inside cooling with lower energy consumption and with better air renewal rate. Therefore, this study aims to analyze the influence of air renewal at university students’ thermal comfort, comparing results of field measurements and subjective searches in classrooms with natural ventilation and a classroom with mechanical ventilation system. The field experiments were carried out in classrooms on the campus of the Universidade do Vale do Rio dos Sinos (Unisinos) in São Leopoldo city, with emphasis at the warmest season of the year. The data were collected from environmental measurements carried out concomitantly with subjective surveys, which were performed through a questionnaire delivered to the students, occupants of the evaluated environments, resulting in a total of 616 questionnaires. The analysis was carried out from the obtained information, and the results presented in the form of graphs and tables, through the crossing between the microclimatic data and the users' answers. The results showed that the classroom occupants with mechanical ventilation presented more satisfactory thermal sensation, comparing to users of other evaluated classrooms. In relation to thermal acceptability in comparative days evaluated, 72.5% of the occupants in classroom with greater air renewal classified the environment as "acceptable" and 27.5% as “unacceptable”. For the other classrooms, only 40% of the occupants classified the environment as "acceptable" and 60% as "unacceptable". The study also showed, at the months in warmest season, a better applicability of the adaptive comfort model in the classroom with higher rates of external airflow. The results also show that the increase of the air renewal rate in the proposed classroom, together with the adaptive actions of the occupants, provided better conditions of thermal comfort when compared to the rooms with natural ventilation.
|
30 |
Estudo por simulação de resfriamento de componentes eletrônicos utilizando jatos sintéticos tangenciaisSilva, Adriano Menezes da 09 May 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-09-29T13:35:20Z
No. of bitstreams: 1
Adriano Menezes da Silva_.pdf: 2391290 bytes, checksum: 70727d4df37a4601ac4cf99773491986 (MD5) / Made available in DSpace on 2017-09-29T13:35:20Z (GMT). No. of bitstreams: 1
Adriano Menezes da Silva_.pdf: 2391290 bytes, checksum: 70727d4df37a4601ac4cf99773491986 (MD5)
Previous issue date: 2017-05-09 / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / O avanço tecnológico da informática e dos componentes eletrônicos está exigindo uma constante pesquisa na busca de maiores eficiências no resfriamento de seus componentes. Os métodos convencionais de resfriamento, através de coolers, não estão suprindo a demanda necessária e vários outros métodos estão sendo testados e implementados. Dentre os métodos utilizados nas pesquisas se destaca o sistema com jatos sintéticos pulsados, onde estudos mostraram que, a eficiência na troca térmica é aumentada devido à turbulência associada e estes dispositivos. As principais vantagens do sistema com jatos sintéticos é a utilização do próprio fluido do meio circundante para efetuar o resfriamento, além da compactação física e diminuição considerável dos níveis de ruído. O estudo visa comparar e ampliar os dados obtidos em experimento prático realizado com placas aquecidas em diferentes posições ao longo do comprimento de um canal, utilizando o jato sintético para realizar o resfriamento. Para realizar a análise numérica realizada utilizando o método por volumes finitos, foi necessário criar um modelo virtual semelhante ao espaço ocupado pelo fluido durante o experimento e nele aplicar as condições reais utilizadas. Sendo assim foram utilizadas na simulação um modelo 3-D e fluido compressível. Estudos de convergência de malha foram realizados para obter a malha que apresenta o melhor benefício entre tempo de processamento e precisão dos resultados. Para maior estabilidade da solução numérica, utilizou-se uma equação que simula o efeito de velocidade do movimento cossenóide da membrana durante o ciclo de excitação. Diversas análises foram realizadas para estabelecer a mesma condição de velocidade média obtida no experimento. Para isso, simulações foram realizadas até a estabilização da velocidade média transiente e os valores obtidos serviram para elaborar uma curva e dela extrair uma equação que capaz de estimar o valor próximo da velocidade média obtida durante as medições do experimento prático para uma determinada condição de contorno de velocidade de membrana. Aplicando a condição de placa aquecida a 80ºC nas duas posições testadas de 50 e 150mm em relação à saída do orifício, verificou-se o aquecimento da placa não interfere nos campos de velocidade e vorticidade médias transientes e instantâneas. As simulações com resfriamento por jatos sintéticos apresentaram resultados significativos de aumento da capacidade de troca térmica em comparação com o regime permanente simulando o sistema convencional de resfriamento por cooler. Os resultados indicam que, com a placa aquecida em posições distintas, a melhora proporcionada pelo jato sintético fica na ordem de 25 a 40%. Já quando comparado o sistema com placa contínua e com variação da amplitude A0, os valores de resfriamento do jato sintético apresentaram aumento na ordem de 125%. Os resultados com alteração de frequência mostram que o coeficiente de transferência de calor por convecção aumenta até a frequência de 120 Hz, indicando que essa é a frequência de ressonância do sistema. / The technological advance of information technology and electronic components provides a constant demand for greater efficiency in the cooling of its components. Cooler or fan-based conventional cooling methods cannot meet this required demand and several other methods are being tested and implemented. Among these methods, pulsed synthetic jets are of particular interest due to the increased heat transfer associated with higher turbulence levels. The main advantages of such a system with synthetic jets are the use of the surrounding environment fluid to realize cooling, compact size and considerable reduction of noise levels. The aim of this study was to compare results with an experimental study performed with heated plates at different positions along the length of a channel using cooled by a tangential synthetic jet and obtain further cooling data. To perform the numerical analysis with a finite volume method, it was necessary to create a virtual model similar to the geometry in the experiment with similar real boundary conditions. Therefore, a 3-D model and a compressible fluid were used in the simulation. Grid convergence studies were performed to obtain a mesh that presented the best balance between processing time and accuracy of results. For greater stability of the numerical solution, an equation was used that simulated the velocity effect of a moving membrane in the driving cavity with a cosine-shaped displacement during the pulsing cycle. Several analyzes were performed to establish the same channel average velocity condition obtained in the experimental study. Simulations were performed until the mean exit channel velocity stabilized and the values obtained were used to elaborate a calibration curve that related the amplitude of the velocity boundary condition at the membrane to an average channel velocity on par with the experimental study. For heat transfer results, a constant temperature of 80 ° C was applied at two test positions of 50 and 150 mm for the plate in relation to the orifice outlet. It was found that plate heating does not interfere in the transient or average velocity and vorticity fields. The simulations with cooling by synthetic jets showed significant increases of thermal exchange capacity in comparison to the a steady turbulent channel flow analogous to a conventional cooler cooling. The results indicate that with the heated plate in different positions the improvement provided by the synthetic jet is in the order of 25 to 40%. When compared to the system with a continuous plate spanning the bottom of the channel, variations of the pulsing jet amplitude showed increase in the order of 125%. Frequency change results show that the convection heat transfer coefficient increases up to the frequency of 120 Hz, indicating that this is the resonant frequency of the channel.
|
Page generated in 0.0658 seconds